首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BackgroundThe single procedure success rates of durable pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) varies between 80 and 90%. Ablation index, incorporating contact force, stability, time and power is a more profound parameter of significant lesion size and has been established. Equally important is a stringent contiguity of the lesion set.Methods and resultsA total number of 100 consecutive patients undergoing de-novo catheter ablation for paroxysmal atrial fibrillation (PAF) were analyzed between 2016 and 2019. In the first 50 patients (group A) PVI was performed using a surround flow, contact force catheter (Biosense Webster Thermocool STSF, Biosense Webster, USA) with a drag-and-ablate technique to encircle the PVs. In the following 50 patients (group B), PVI was performed using ablation index and a stringent lesion contiguity with an interlesion distance (ILD) of <5 mm. The baseline characteristics showed no significant differences between both groups. During a mean follow-up of 18 ± 3 months after a single procedure, 36 (72%) patients of group A were free of arrhythmia recurrence versus 43 (86%) patients in group B (p = 0.047). A total of 14 patients (group A: 10 (20%), group B: 4 (8%); underwent a redo-procedure. 7 patients of group A (14%) and 2 patients of group B (4%) showed recovered veins. In 3 patients of group A and 2 patients of group B the PVs were durably isolated. In these patients persistent AF recurrence was caused by extra-PV AF sources. Four patients of group A and three patients of group B had continued paroxysmal or persistent AF but did not undergo redo-procedure. With regard to the procedural data, the procedure time, the total energy and the fluoroscopy time were significantly lower in group B (AI and ILD <5 mm) (128.86 ± 18.19 versus 115.35 ± 15.38; p < 0.05; 1619.16 ± 988.56 versus 1186.26 ± 756.34; p < 0.05; 11.49 ± 3.20 versus 9.66 ± 3.86; p = 0.04). Both procedures were performed with a low number of complications, no pericardial effusion was seen in either group.ConclusionsPVI using ablation index in combination with a stringent lesion contiguity improves clinical outcome after first-time PVI with lower PVI recovery, shorter procedure times, lower total energy and shorter fluoroscopy times and therefore, is more efficient.  相似文献   

2.
IntroductionElectrical pulmonary vein isolation (PVI) is used for the invasive treatment of atrial fibrillation (AF). However, despite the procedure’s technical evolution, the rate of AF recurrence due to electrical reconnection of the PVs is high. The aims of this study was to assess the influence of left common pulmonary venous ostium (LCO) on clinical outcomes following PVI.MethodsRetrospective cohort of 254 patients who underwent the first procedure of PVI from the years 2013–2018 was assessed. Patients with persistent AF of long duration and extra-pulmonary focus associated with triggers for arrhythmia were excluded. Patients were stratified into two groups according to the presence of a LCO and received follow up for atrial tachyarrhythmia-free survival. The mean follow-up period was 28 ± 1.73 months.ResultsThe majority were men (68.5%), with a mean age of 54 ± 12 years. With respect to the atrial anatomy, LCO occurred in 23.6% of cases after pulmonary venous angiotomography. The arrhythmia-free survival rate was 79.5% in the follow-up period. The Cox regression model was utilized and the adjusted hazard ratio for LCO was 0.36 (95% CI 0.15–0.87; p = 0.02) in terms of age, body mass index, left atrium diameter, bi-directional blocking of the cavotricuspid isthmus, persistent AF, left ventricular ejection fraction adjusted model.ConclusionAnatomic abnormality with the presence of the LCO is present in a quarter of patients undergoing AF ablation, which is associated with a lower rate of arrhythmia recurrence in our population.  相似文献   

3.
IntroductionConflicting results regarding the impact of left common pulmonary vein (LCPV) on clinical outcome of atrial fibrillation (AF) ablation with cryoballoon technology have been reported.MethodsWe systematically searched PubMed and Cochrane library for articles that compared the arrhythmia recurrence rate after cryoballoon ablation between patients with normal pattern PVs and patients with LCPV. Studies of first ablation for persistent and paroxysmal AF using the 28 mm Arctic Front Advance, Medtronic cryoballoon (CB-A) reporting clinical success rates at a mean follow-up of ≥12 months were included. Data were analyzed by applying a random effects model.ResultsA total of 5 studies with a total of 1178 patients met our predefined inclusion criteria. After a mean follow-up of 18.4 months, the overall success rate of CB-A ablation among patients with persistent and paroxysmal AF was 57%; in the LCPV group the success rate was 46% and in the normal anatomical pattern group it was 61%. No significant heterogeneity was noted among the studies (I2 = 35.8%; Q (df = 3) = 6.23 p-value = 0.18). Arrhythmia recurrence after CB-A ablation was not statistically significant between the two groups (LogOR 0.24; 95% CI [-0.16-0.63]; p-value = 0.23). No significant difference in PNI was observed between the two groups (p-value = 0.693).ConclusionThe presence of LCPV does not affect the long-term outcome of paroxysmal and persistent atrial fibrillation ablation with 28 mm CB-A compared to normal left PVs pattern.  相似文献   

4.
BackgroundHigh-power short-duration (HPSD) and cryoballoon ablation (CBA) has been used for pulmonary vein isolation (PVI).ObjectiveWe aimed to compare the efficacy of PVI between CBA and HPSD ablation in patients with paroxysmal atrial fibrillation (PAF).MethodsWe retrospectively analyzed 251 consecutive PAF patients from January 2018 to July 2020. Of them, 124 patients (mean age 57.2 ± 10.1 year) received HPSD and 127 patients (mean age 59.6 ± 9.4 year) received CBA. In HPSD group, the radiofrequency energy was set as 50 W/10 s at anterior wall and 40 W/10 s at posterior wall. In CBA group, 28 mm s generation cryoballoon was used for PVI according the guidelines.ResultsThere was no significant difference in baseline characteristics between these 2 groups. The time to achieve PVI was significantly shorter in cryoballoon ablation group than in HPSD group (20.6 ± 1.7 min vs 51.8 ± 36.3, P = 0.001). The 6-month overall recurrence for atrial tachyarrhythmias was not significantly different between the two groups (HPSD:14.50% vs CBA:11.0%, P = 0.40). There were different types of recurrent atrial tachyarrhythmia between these 2 groups. Recurrence as atrial flutter was significantly more common in CBA group compared to HPSD group (57.1% vs 12.5%, P = 0.04).ConclusionIn PAF patients, CBA and HPSD had a favourable and comparable outcome. The recurrence pattern was different between CBA and HPSD groups.  相似文献   

5.
Atrial fibrillation (AF) is the most common form of arrhythmia encountered in clinical practice. Its presence causes a rapid and irregular ventricular response, being the topic of intensive research in rate control therapies of AF. To this respect, recent studies suggest that ventricular response is notably influenced by atrial activity (AA) temporal organization. However, the interdependency between atrial and ventricular activations has not been adequately explored to date in real-life AF patients. The present work introduces a novel methodology to quantitatively assess synchronization and coupling between real atrial and ventricular activation series. Furthermore, the method operates on surface ECG recordings, thus providing an easy and cost-effective way to be applied. The method is based on a nonlinear index, such as cross-sample entropy (CSE), which estimates the conditional probability to find similar patterns within both activation series. The study has been carried out on patients with paroxysmal and persistent AF in order to be applied over atrial activation series with different properties in their organization. Results showed a statistically significant positive correlation between AA organization and the synchronization between atrial and ventricular activations (R = 0.53, p < 0.01). Furthermore, higher CSE values were observed for persistent (0.759 ± 0.053) than for paroxysmal AF episodes (0.662 ± 0.091), thus suggesting more synchronization between atrial and ventricular activations in paroxysmal AF. As a consequence, CSE provided findings consistent with previous works and could be used to reveal clinically useful information in the improvement of current rate control therapies, which are mainly focused on controlling ventricular rate without paying much attention to the atrial fibrillatory process.  相似文献   

6.
ObjectiveTo examine the learning curves of atrial fibrillation (AF) ablation comparing the cryoballoon (CB) and radiofrequency (RF) catheters.MethodsWe performed a retrospective data analysis from the initiation of AF ablation program in our center. For CB ablation, a second generation 28 mm balloon was utilized and for RF ablation.ResultsA total of 100 consecutive patients (50 in each group) have been enrolled in the study (male 74%, mean age 58.9 ± 10 years, paroxysmal AF 85%). The mean procedure time was shorter for CB (116.6 ± 39.8 min) than RF group (191.8 ± 101.1 min) (p < 0.001). There was no difference in the mean fluoroscopy time, 24.2 ± 10.6 min in RF and 22.4 ± 11.7 min in CB group, (p = 0.422). Seven major complications occurred during the study; 5 in RF group (10%) and 2 in CB group (4%) (p = 0.436). After the mean follow up of 14.5 ± 2.4 months, 15 patients in RF group (30%) and 11 in CB group (26%) experienced AF recurrences (P = 0.300).ConclusionWhen starting a new AF ablation program, our results suggest that CB significantly shortens procedure while fluoroscopy time and clinical outcomes are comparable to RF ablation.  相似文献   

7.
Aim. To investigate long-term outcome and to determine predictors of successful pulmonary vein isolation (PVI) in patients with symptomatic paroxysmal or persistent atrial fibrillation (AF) who are refractory or intolerant to antiarrhythmic drugs. Background. The treatment of AF has traditionally been pharmacological aimed at rate or rhythm control. However, rhythm control remains difficult to establish. PVI is reported to be effective in selected patient groups. Methods. Ninety-nine consecutive patients with a mean age of 54±10 years who had paroxysmal or persistent AF were treated in the University Medical Center Groningen. All patients underwent PVI by the same electrophysiologist. Successful PVI was defined as absence of AF on Holter or electrocardiogram (ECG), and no symptoms of AF. Results. After six months of follow-up, 60 (61%) patients were free of AF episodes, both on 96-hour Holter monitoring and on ECGs, and had no symptoms related to AF. Thirty-nine of these 60 patients (65%) were no longer treated with any class I or III antiarrhythmic drugs. Independent determinants of successful PVI were paroxysmal AF (OR 18 [3.5–93], p=0.001), and left pulmonary vein ablation time >55 minutes (OR 15 [2.7–81], p=0.002). Left atrial (parasternal view 42±6 vs. 40±5 mm, p<0.05 and apical view 61±9 vs. 58±8 mm, p<0.05) and right atrial (59±7 vs. 56±5 mm, p<0.05) sizes decreased significantly in the successfully treated patients after six months of follow-up. Conclusion. Independent determinants of a successful outcome after PVI are paroxysmal AF and a longer left atrial ablation time. (Neth Heart J 2009;17:366–72.)  相似文献   

8.
IntroductionThe efficacy of catheter ablation in patients with low cardiac function has been previously reported; however, only a few studies have included mid-range ejection fraction (mrEF). This study aimed to evaluate the efficacy and safety of atrial fibrillation (AF) ablation in patients with left ventricular ejection fraction (LVEF) < 50%.MethodsThis study retrospectively analyzed 79 patients (reduced ejection fraction [rEF]/mrEF, 38/41; paroxysmal/persistent, 37/42; heart failure hospitalizations within one year before ablation, 36 [45.6%]) who underwent the first ablation procedure at our hospital from April 2017 to December 2021. Radiofrequency ablation and cryoablation were performed for 69 and 10 patients, respectively.ResultsComplications included pacemaker implantation for postoperative sick sinus syndrome in one patient and inguinal hematoma in one patient. Regarding efficacy, there were significant postoperative improvements in echocardiographic data, blood test values, and diuretic use. After a mean follow-up of 60 months, 86.1% patients had no AF recurrence. There were 9 heart failure hospitalizations (11.4%) and 5 all-cause deaths (6.3%); no significant differences were found between the rEF and mrEF groups. No significant predictors of AF recurrence were found in preoperative patient characteristics.ConclusionAF ablation in patients with LVEF <50% significantly improved cardiac and renal functions with few complications, resulting in a high non-recurrence rate and reduced heart failure.  相似文献   

9.
10.
IntroductionWe describe the use of a ablating system to compartmentalise and regionally isolate the atria in paroxysmal and persistent atrial fibrillation (AF).Methods40 patients were studied, 25 paroxysmal AF and 14 persistent AF. One patient enrolled was later found to be in left atrial flutter and was excluded. The Cardima Revelation® TX catheter system with Intellitemp® Radiofrequency (RF) energy control device and a Medtronic Atakar® RF generator were used to place wide area circumferential ablations to achieve conduction block into the left and right sided pulmonary veins. Roof lines and mitral isthmus lines were also performed. In patients with persistent AF and in repeat procedures, right atrial compartmentalisation was performed with an anterior superior vena cava (SVC) to inferior vena cava (IVC) line and a septal SVC to IVC line.ResultsAt 6 months, 18 of the 39 patients were asymptomatic, 10 had improved symptoms and 22 were in sinus rhythm. In the paroxysmal group, 11 were asymptomatic, 7 had improved symptoms and 16 (64%) were in sinus rhythm. In the persistent group, 7 were asymptomatic, 3 had improved symptoms and 6 (43%) were in sinus rhythm. The total group AF burden was 37.8 ± 5.4 hrs pre-procedure and 23.1 ± 5.1 hrs at 6 months post procedure. Mean temperature, impedance and power recorded at each pole demonstrated effective power delivery at all poles. No catheter charring was observed, complication rates were comparable to standard AF ablation technique.ConclusionLinear ablation in the left and right atria to mimic Cox’s Maze is feasible and safe using this ablating system.  相似文献   

11.
Background

Healthy atrial fibrillation (AF) patients will eventually outgrow their low thromboembolic risk. The purpose of this study is to compare the development of cardiovascular disease in healthy AF patients as compared to healthy sinus rhythm patients and to assess appropriate anticoagulation treatment.

Methods

Forty-one idiopathic paroxysmal AF patients (56 ± 10 years, 66% male) were compared with 45 healthy sinus rhythm patients. Patients were free of hypertension, antihypertensive and antiarrhythmic drugs, diabetes, congestive heart failure, coronary artery or peripheral vascular disease, previous stroke, thyroid, pulmonary and renal disease, and structural abnormalities on echocardiography.

Results

Baseline characteristics and echocardiographic parameters were the same in both groups. During 10.7 ± 1.6 years, cardiovascular disease and all-cause death developed significantly more often in AF patients as compared to controls (63% vs 31%, log rank p < 0.001). Even after the initial 5 years of follow-up, survival curves show divergent patterns (log rank p = 0.006). Mean duration to reach a CHA2DS2-VASc score > 1 among AF patients was 5.1 ± 3.0 years. Five of 24 (21%) patients with CHA2DS2-VASc > 1 did not receive oral anticoagulation therapy at follow-up. Mean duration of over- or undertreatment with oral anticoagulation in patients with CHA2DS2-VASc > 1 was 5 ± 3.0 years.

Conclusion

The majority of recently diagnosed healthy AF patients develop cardiovascular diseases with a consequent change in thromboembolic risk profile within a short time frame. A comprehensive follow-up of this patient category is necessary to avoid over- and undertreatment with anticoagulants.

  相似文献   

12.
PurposeThe Biotronik LinoxSmart DX implanted cardioverter defibrillator (ICD) lead is a novel VDD lead with the advantage of integrated atrial sensing dipole combined with a special augmentation and filtering mechanisms. We sought to determine the efficacy of the Biotronik LinoxSmart DX ICD lead.MethodsNon-randomized consecutive patients implanted with Biotronik LinoxSmart DX lead at Sheba Medical Center were included in this study. Electrical parameters and arrhythmic events were recorded during follow up of one year.ResultsSeventy-three patients (69 males (94.5%), mean age 61 ± 12 years) were included. All patients were successfully implanted with a Biotronic VR-T DX device and LinoxSmart DX ICD lead (DX-17 in 37% and DX-15 in 63% patients). Mean P wave amplitude at time of implantation was 3.66 ± 2.9 mV and improved significantly throughout the follow-up (5.29 ± 4.39 mV, p = 0.009). Appropriate atrial sensing (defined as P wave amplitude of ≥0.8 mV) rate of 100% at implantation significantly decreased to 89% (p = 0.015) at 12 months. Three out of 67 (4.5%) patients without a known history of atrial fibrillation had documented new onset paroxysmal atrial fibrillation. Appropriate shocks occurred in 4 (5.5%) patients. One patient with atrial sensing less than 0.4 mV had inappropriate shock.ConclusionsAmong patients implanted with the Biotronik LinoxSmart DX ICD lead in our single center, appropriate atrial sensing rate decreased over 12 months. Larger studies are needed to evaluate the reliability of long term appropriate atrial sensing.  相似文献   

13.
目的:比较射频消融对阵发性和长期持续性心房颤动(房颤)患者生活质量的改善。方法:纳入2011年5月至2016年8月接受射频消融治疗的阵发性房颤患者142例和长期持续性房颤61例。消融前和消融后12个月采用健康状况调查简表(SF-36)评估患者生活质量。结果:长期持续性房颤患者年龄及合并高血压和慢性心功能不全的比例高于阵发性房颤组。消融后12个月,两组患者心理健康(MCS)和生理健康(PCS)评分均显著提高(P0.01)。长期持续性房颤患者MCS和PCS的改善幅度显著高于阵发性房颤组(P0.01)。房颤未复发患者生活质量的提高幅度显著高于复发患者(P0.01)。结论:射频消融改善长期持续性房颤患者生活质量的幅度高于阵发性房颤,房颤复发将影响患者的生活质量。  相似文献   

14.

Background

Ganglionated plexi (GP) ablation has been become an adjunct to pulmonary vein isolation (PVI). This study describes the long-term results of minimally invasive surgical PVI, ablation of GPs, and exclusion of the left atrial appendage for atrial fibrillation (AF).

Methods

Long-term follow-up of 55 months was performed in 139 consecutive patients (age 58.3±20.8 years) with symptomatic, drug-refractory lone AF who underwent minimally invasive surgical PVI, GPs ablation, and exclusion of the left atrial appendage. Success was defined as freedom from AF, atrial flutter, or atrial tachycardia off antiarrhythmic drugs.

Results

AF was paroxysmal in 77.7%, persistent in 12.2% and long-standing persistent in 10.1%. Single-procedure success rate was 71.7%, 59.4% and 46.6% at 12, 24 and 60 months respectively. Single-procedure success rate was 72.9%, 62.6% and 51.8% for paroxysmal AF, 64.7%, 35.3%, and 28.2% for persistent AF, 71.4%, 64.3% and 28.6% for long-standing persistent AF at 12, 24 and 60 months respectively. Duration of AF>24 months (hazard ratio [HR]: 3.09, 95% confidence interval [CI]: 1.51 to 6.32; p = 0.002), left atrial diameter≥40 mm (HR: 4.03, 95% CI: 1.88 to 8.65; p<0.001), early recurrence of AF (HR: 4.66, 95% CI: 2.25 to 9.63; p<0.001) independently predicted long-term recurrence of AF. There was no procedure-related death. One patient converted to median sternotomy because of uncontrolled bleeding. Two patients underwent perioperative cerebrovascular events.

Conclusions

At nearly 5-year of clinical follow-up, single-procedure success rate of minimally invasive surgical PVI with GP ablation was 51.8% for paroxysmal AF, 28.2% for persistent AF, 28.6% for long-standing persistent AF after initial procedure. Patients with AF duration≤24 months, left atrial diameter<40 mm and no early recurrence of AF, had favorable outcomes.  相似文献   

15.
BackgroundThe Arctic Front Cryoballoon System is a technology in which substrate alterations in patients with atrial fibrillation (AF) recurrence have not been well characterized. In this study, we evaluated sites of pulmonary vein (PV) reconnections and the accuracy of the Achieve? circular mapping catheter in detecting these reconnections after cryoablation.MethodsThis study included 15 patients undergoing redo AF ablation after a prior single cryoablation procedure. PV reconnection sites were determined by measuring PV signals and high output pacing from 4 vectors of the Achieve catheter. The results were compared with a roving mapping catheter guided by rotational intracardiac echocardiography (ICE) in the left atrium.ResultsAll patients had PV reconnections (2.1 ± 0.8 veins/patient). The left superior PV was most commonly reconnected (n = 11), whereas the right inferior PV was least likely (n = 3). Both carinas (left: n = 11; right: n = 7) and left atrial appendage ridge (n = 11) were also frequently reconnected. Mapping with the Achieve catheter showed a positive predictive value (PPV) 100% and negative predictive value (NPV) 96% when compared with ICE guided mapping. In 2 patients, right superior PV reconnection was not identified by the Achieve.ConclusionDuring redo AF ablation after index cryoablation, multiple PVs are usually reconnected, with both carinas and left atrial appendage ridge being common sites of reconnection. The Achieve mapping catheter was able to identify reconnection with high positive and negative predictive values.  相似文献   

16.

Background

Paroxysmal atrial fibrillation (PAF) is defined as recurrent AF terminating spontaneously within 7 days. This definition allows the consideration of any AF occurrence lasting < 7 days as paroxysmal, irrespective of the frequency and duration of episodes. The aim of this study was to investigate symptomatic AF burden (AFB) defined as total duration of symptomatic AF episodes within 3 months prior to abalation, for prediction of outcome after pulmonary vein isolation (PVI).

Methods

A total of 320 consecutive patients with symptomatic AF (PAF=244, men=214, age=58 y) were enrolled. AFB in patients with PAF was defined as time spent in AF within 3 months prior to PVI. After the AFB cut-off point was optimized at 500 h, patients with PAF were categorized into 2 groups: Group 1 - patients with AFB< 500 h (n=192), Group 2 - patients with AFB≥ 500 h (n=52). Patients with persistent AF (PersAF, n = 76) comprised control group (Group 3). PVI was performed either with irrigated tip catheter (n=215) or using cryoballoon (n=105). The endpoint of study was first documented recurrence of AF >30 sec.

Results

Symptomatic AFB was found to be appropriate for prediction of outcome after PVI. The freedom from AF within 2 years was observed in 69%, 31%, and 43% patients in Group 1, 2 and 3, respectively (Group 1 vs. Group 2, p < .001; Group 1 vs. Group 3, p< .001; Group 2 vs. Group 3, p = 0.46).

Conclusions

Low AFB < 500 h /3 months was associated with better outcome after PVI. Patients with PAF and high AFB should be treated as patients with PersAF.  相似文献   

17.
BackgroundThere are limited data describing the experience of radiofrequency (RF) vs. cryoballoon (CB) ablation for atrial fibrillation (AF) among elderly patients in the United States.MethodsWe conducted a retrospective analysis of patients ≥75 years of age undergoing index RF vs. CB ablation between January 2014 and May 2020 at our center. The choice of ablation technique was left to the operator's discretion. Major complications and efficacy, defined as freedom from any atrial tachyarrhythmia (ATA) lasting ≥30 s after one year of follow-up, were assessed in patients with index RF vs. CB ablation.ResultsIn our cohort of 186 patients, the median age was 78 (76–81) years, 54.8% were men, and 39.2% had persistent AF. The median CHA2DS2-VASc score was 4 (3–4), while the median duration of AF was 3 (1–7) years. The majority (n = 112, 60.2%) underwent RF ablation. The median procedure time was significantly lower in CB group (197 vs 226.5 min, p=<0.01). The incidence of complications was similar in the two sub-groups (RF: 1.8% vs. CB: 2.7%, p = 0.67). Similarly, arrhythmia-free survival rate on antiarrhythmic drugs at 1-year follow-up remained statistically comparable (63.4% vs. 68.9%, p = 0.33) between patients receiving RF vs. CB ablation.ConclusionThe safety and efficacy of RF vs. CB ablation for AF remained comparable in our cohort of patients older than 75 years. CB ablation was associated with a shorter procedure time.  相似文献   

18.
Trimethylamine N‐oxide (TMAO) is an independent risk factor of cardiovascular disease. Our objective was to explore the relation between TMAO and ischemic stroke (IS) in patients with atrial fibrillation (AF). A total of 68 patients with AF with IS and 111 ones without IS were enrolled. The plasma levels of TMAO remarkably increased in IS‐AF patients (8.25 ± 1.58 µM) compared with patients with AF (2.22 ± 0.09 µM, P < 0.01). The receiver operating characteristic analysis revealed that the best cutoff value of TMAO to predict IS in patients with AF was 3.53 µM with 75.0% sensitivity and 92.8% specificity (area under the curve: 0.917, 95% confidence intervals: 0.877‐0.957). Univariate and multivariate logistic regression analysis showed that TMAO was an independent predictor in IS. The level of TMAO was correlated with the CHA2DS2‐VASc score. In conclusion, TMAO was an independent predictor of IS, which could potentially refine stroke stratification in patients with AF.  相似文献   

19.

Background

Third-generation cryoballoon (CB3) is characterized by a 40% shorter distal tip designed to increase the rate of pulmonary veins real-time signal recording in order to measure time necessary to isolate veins, the “Time to effect” (TTE). Few data are currently available on clinical follow up of CB3 treated patients.

Methods

Sixtyeight consecutive patients (mean age 57.8?±?9.6 years, 48 male) with paroxysmal or persistent atrial fibrillation (AF) were enrolled. Thirthyfour (25 paroxysmal AF) underwent to a 28 mmCB3 pulmonary veins isolation and were compared to 34 treated (21 paroxysmal AF) with 28 mmCB2.

Results

CB3 use was correlated to significant increase of the possibility to measure TTE in every treated veins (left superior 82,35% vs 23,53%, left inferior 70,59% vs 38,24%, right superior 58,82% vs 14,71%, right inferior 52,94% vs 17,65%). When it is measured, TTE wasn't different between two groups. Higher nadir temperature was observed in CB3 patients (?39.4?±?5.2?°C vs ?43.0?±?7.2?°C, p?=?0.03). CB3 procedures were shorter (91.4?±?21.7 vs 110.9?±?31.8?min, p?=?0.018), with a significant reduction in cryoenergy delivery time (24.2?±?8.5 vs 20.3?±?6.7?min, p?<?0.05), and a significant reduction in left atrium dwell time (59.3?±?9.8 vs 69.3?±?10.8?min, p?=?0.02, p?<?0.05). At one year follow up period the Kaplan-Meier curve didn't show any significant difference in AF-free survival (Log p?=?0,49).

Conclusions

Novel CB3 is a useful tool in order to simplify AF cryoballoon ablation when compared to second generation cryoballoon, as observed in our experience. Follow up data seem confirm a clinical CB3 efficacy at least comparable CB2.  相似文献   

20.

Background

Radiofrequency catheter ablation of atrial fibrillation (AF) has been proved to be effective and to prevent progressive left atrial (LA) remodeling. Cryoballoon catheter ablation (CCA), using a different energy source, was developed to simplify the ablation procedure. Our hypothesis was that successful CCA can also prevent progressive LA remodeling.

Methods

36 patients selected for their first CCA because of nonvalvular paroxysmal AF had echocardiography before and 3, 6 and 12 months after CCA. LA diameters, volumes (LAV) and LA volume index (LAVI) were evaluated. LA function was assessed by: early diastolic velocities of the mitral annulus (Aasept, Aalat), LA filling fraction (LAFF), LA emptying fraction (LAEF) and the systolic fraction of pulmonary venous flow (PVSF). Detailed left ventricular diastolic function assessment was also performed.

Results

Excluding recurrences in the first 3-month blanking period, the clinical success rate was 64%. During one-year of follow-up, recurrent atrial arrhythmia was found in 21 patients (58%). In the recurrent group at 12 months after ablation, minimal LAV (38 ± 19 to 44 ± 20 ml; p < 0.05), maximal LAV (73 ± 23 to 81 ± 24 ml; p < 0.05), LAVI (35 ± 10 to 39 ± 11 ml/m2; p = 0.01) and the maximal LA longitudinal diameter (55 ± 5 to 59 ± 6 mm; p < 0.01) had all increased. PVSF (58 ± 9 to 50 ± 10%; p = 0.01) and LAFF (36 ± 7 to 33 ± 8%; p = 0.03) had decreased. In contrast, after successful cryoballoon ablation LA size had not increased and LA function had not declined. In the recurrent group LAEF was significantly lower at baseline and at follow-up visits.

Conclusions

In patients whose paroxysmal atrial fibrillation recurred within one year after cryoballoon catheter ablation left atrial size had increased and left atrial function had declined. In contrast, successful cryoballoon catheter ablation prevented progressive left atrial remodeling.  相似文献   