首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The purpose of this study was to compare the effects of warm-up protocols using either whole-body vibration (WBV) or cycle ergometry (CE) on peak torque at 3 different isokinetic speeds and on fatigue in the knee extension exercise. Twenty-seven recreationally trained (age = 23.59 ± 3.87 years) men (n = 14) and women (n = 13) were tested at 3 different isokinetic speeds (60, 180, 300°·s-1) after either WBV or CE warm-up. The WBV consisted of intermittent bouts of 30 seconds of isometric squats at various degrees of hip and knee flexion for a total of 5 minutes. The CE consisted of 5 minutes of pedaling a cycle ergometer at 65-85% of age-predicted max heart rate. Comparisons between the warm-up conditions were analyzed using repeated measures analysis of variance. For the fatigue comparison, subjects completed 50 continuous concentric knee extensions at 240°·s-1. Means from the first 3 repetitions were compared to means from the final 3 repetitions to establish a fatigue index. Conditions were compared through an independent T-test. No significant (p > 0.05) differences were discovered between warm-up conditions at any speed or on the fatigue index. Means were virtually identical at 60°·s-1 (WBV = 142.14 ± 43.61 ft lb-1; CE = 140.64 ± 42.72 ft lb-1), 180° s-1 (WBV = 93.88 ± 35.18 ft lb-1; CE = 96.36 ± 31.53 ft lb-1), and 300°·s-1 (WBV = 78.36 ± 26.04 ft lb-1; CE = 80.13 ± 26.08), and on fatigue percentage (WBV = 51.14 ± 10.06%; CE = 52.96 ± 9.19%). These data suggest that the more traditional 5-minute cycle ergometer warm-up elicits results comparable to a less common vibration warm-up. The findings of this study are that these modalities are comparable under the tested conditions.  相似文献   

2.
The purpose of this study was to evaluate maximal torque of the knee flexors and extensors, flexor/extensor ratios, and maximal torque differences between the 2 lower extremities in young track and field athletes. Forty male track and field athletes 13-17 years old and 20 male nonathletes of the same age participated in the study. Athletes were divided into 4 groups according to their age and event (12 runners and 10 jumpers 13-15 years old, 12 runners and 6 jumpers 16-17 years old) and nonathletes into 2 groups of the same age. Maximal torque evaluation of knee flexors and extensors was performed on an isokinetic dynamometer at 60°·s(-1). At the age of 16-17 years, jumpers exhibited higher strength values at extension than did runners and nonathletes, whereas at the age of 13-15 years, no significant differences were found between events. Younger athletes were weaker than older athletes at flexion. Runners and jumpers were stronger than nonathletes in all relative peak torque parameters. Nonathletes exhibited a higher flexor/extensor ratio compared with runners and jumpers. Strength imbalance in athletes was found between the 2 lower extremities in knee flexors and extensors and also at flexor/extensor ratio of the same extremity. Young track and field athletes exhibit strength imbalances that could reduce their athletic performance, and specific strength training for the weak extremity may be needed.  相似文献   

3.
Measures of knee joint function, although useful in predicting injury, can be misleading because hip position in traditional seated isokinetic tests is dissimilar to when injuries occur. This study aimed to determine the differences between seated and supine peak torques and strength ratios and examine the interaction of position with joint velocity. This was a cross-sectional, repeated measures study. Isokinetic knee extensor and flexor concentric and eccentric peak torque was measured seated and supine (10° hip flexion) at 1.04 and 3.14 rad·s(-1) in 11 Rugby players. Repeated measures analysis of variance and paired t-tests were used to analyze peak torques and strength ratios. Bonferroni post hoc, limits of agreement, and Pearson's correlation were applied. Seated peak torque was typically greater than that for supine for muscle actions and velocities. The values ranged from 109 ± 18 N·m (mean ± σ) for supine hamstring concentric peak torque at 1.04 rad·s(-1) to 330 ± 71 for seated quadriceps eccentric peak torque at 1.04 rad·s(-1). There was a significant position × muscle action interaction; eccentric peak torque was reduced more than concentric in the supine position. Knee joint strength ratios ranged from 0.47 ± 0.06 to 0.86 ± 0.23, with a significant difference in means between supine and seated positions for functional ratio at 3.14 rad·s(-1) observed; for seated it was 0.86 ± 0.23; and for supine, it was 0.68 ± 0.15 (p < 0.05). Limits of agreement for traditional and functional ratios ranged from 1.09 ×/÷ 1.37 to 1.13 ×/÷ 1.51. We conclude that hip angle affects isokinetic peak torques and knee joint strength ratios. Therefore, the hip angle should be nearer 10° when measuring knee joint function because this is more ecologically valid. Using similar protocols, sports practitioners can screen for injury and affect training to minimize injury.  相似文献   

4.
We examined the temporal changes of isokinetic strength performance of knee flexor (KF) and extensor (KE) strength after a football match. Players were randomly assigned to a control (N = 14, participated only in measurements and practices) or an experimental group (N = 20, participated also in a football match). Participants trained daily during the two days after the match. Match and training overload was monitored with GPS devices. Venous blood was sampled and muscle damage was assessed pre-match, post-match and at 12h, 36h and 60h post-match. Isometric strength as well as eccentric and concentric peak torque of knee flexors and extensors in both limbs (dominant and non-dominant) were measured on an isokinetic dynamometer at baseline and at 12h, 36h and 60h after the match. Functional (KFecc/KEcon) and conventional (KFcon/KEcon) ratios were then calculated. Only eccentric peak torque of knee flexors declined at 60h after the match in the control group. In the experimental group: a) isometric strength of knee extensors and knee flexors declined (P<0.05) at 12h (both limbs) and 36h (dominant limb only), b) eccentric and concentric peak torque of knee extensors and flexors declined (P<0.05) in both limbs for 36h at 60°/s and for 60h at 180°/s with eccentric peak torque of knee flexors demonstrating a greater (P<0.05) reduction than concentric peak torque, c) strength deterioration was greater (P<0.05) at 180°/s and in dominant limb, d) the functional ratio was more sensitive to match-induced fatigue demonstrating a more prolonged decline. Discriminant and regression analysis revealed that strength deterioration and recovery may be related to the amount of eccentric actions performed during the match and athletes'' football-specific conditioning. Our data suggest that recovery kinetics of knee flexor and extensor strength after a football match demonstrate strength, limb and velocity specificity and may depend on match physical overload and players'' physical conditioning level.  相似文献   

5.
From a cycling paradigm, little has been done to understand the relationships between maximal isometric strength of different single joint lower body muscle groups and their relation with, and ability to predict PPO and how they compare to an isometric cycling specific task. The aim of this study was to establish relationships between maximal voluntary torque production from isometric single-joint and cycling specific tasks and assess their ability to predict PPO. Twenty male trained cyclists participated in this study. Peak torque was measured by performing maximum voluntary contractions (MVC) of knee extensors, knee flexors, dorsi flexors and hip extensors whilst instrumented cranks measured isometric peak torque from MVC when participants were in their cycling specific position (ISOCYC). A stepwise regression showed that peak torque of the knee extensors was the only significant predictor of PPO when using SJD and accounted for 47% of the variance. However, when compared to ISOCYC, the only significant predictor of PPO was ISOCYC, which accounted for 77% of the variance. This suggests that peak torque of the knee extensors was the best single-joint predictor of PPO in sprint cycling. Furthermore, a stronger prediction can be made from a task specific isometric task.  相似文献   

6.
Power output and work in different muscle groups during ergometer cycling   总被引:1,自引:0,他引:1  
The aim of this study was to calculate the magnitude of the instantaneous muscular power output at the hip, knee and ankle joints during ergometer cycling. Six healthy subjects pedalled a weight-braked bicycle ergometer at 120 watts (W) and 60 revolutions per minute (rpm). The subjects were filmed with a cine camera, and pedal reaction forces were recorded from a force transducer mounted in the pedal. The muscular work at the hip, knee and ankle joint was calculated using a model based upon dynamic mechanics described elsewhere. The mean peak concentric power output was, for the hip extensors, 74.4 W, hip flexors, 18.0 W, knee extensors, 110.1 W, knee flexors, 30.0 W and ankle plantar flexors, 59.4 W. At the ankle joint, energy absorption through eccentric plantar flexor action was observed, with a mean peak power of 11.4 W and negative work of 3.4 J for each limb and complete pedal revolution. The energy production relationships between the different major muscle groups were computed and the contributions to the total positive work were: hip extensors, 27%; hip flexors, 4%; knee extensors, 39%; knee flexors, 10%; and ankle plantar flexors 20%.  相似文献   

7.
Although there has been substantial research on the acute effects of static stretching on subsequent force and power development, the outcome after stretching of the antagonist musculature has not been examined. The purpose of this study was to investigate the effects of static stretching of antagonist musculature on multiple strength and power measures. Sixteen trained men were tested for vertical jump height and isokinetic peak torque production during knee extension at 60°.s (SlowKE) and 300°.s (FastKE). Electromyography was recorded for the vastus lateralis and the biceps femoris muscles during isokinetic knee extension. Subjects performed these tests in a randomized counterbalanced order with and without prior stretching of the antagonist musculature. Paired samples t-tests indicated significantly greater torque production during the FastKE when preceded by stretching of the antagonist musculature vs. the nonstretch trial (102.2 vs. 93.5 N.m; p = 0.032). For SlowKE, torque production was not significantly different between the trials (176.7 vs. 162.9 N.m; p = 0.086). Vertical jump height (59.8 vs. 58.6 cm; p = 0.011) and power (8571 vs. 8487 W; p = 0.005) were significantly higher after the stretching trial vs. the nonstretching trial. Electromyography responses were similar between the trials. These results suggest that static stretching of the antagonist hamstrings before high-speed isokinetic knee extension increases the torque production. Furthermore, stretching the hip flexors (emphasis on single-joint hip flexors) and dorsiflexors, the antagonists of the hip extensors and plantarflexors, may enhance jump height and power, although the effect sizes were small.  相似文献   

8.
Twenty young men trained the right knee extensors and flexors on an isokinetic dynamometer three times weekly over a 10-week period. During each session, 10 men in the slow training group completed three sets of 8 maximal contractions at a rate of 1.05 rad s-1, whereas the other 10, the fast group, completed three sets of 20 contractions at a rate of 4.19 rad s-1. Subjects wer pre- and post-tested for peak torque and power on an isokinetic dynamometer at 1.05, 3.14, and 4.19 rad s-1. Proportions of muscle fibre-types and fibre cross-sectional areas were determined from biopsy specimens taken before and after training from the right vastus lateralis. When testing was conducted at 1.05 rad s-1, the slow group improved (P less than 0.05) peak torque by 24.5 N m (8.5%), but no change was noted for the fast group. Power increased (P less than 0.05) by 32.7 W (13.6%) in the slow group and 5.5 W (2.5%) in the fast. At 3.14 rad s-1, both groups increased (P less than 0.05) peak torque and power. At 4.19 rad s-1, the fast group increased (P less than 0.05) peak torque by 30.0 N m (19.7%), whereas no training effect was observed in the slow group. There was no significant change in power in either group at 4.19 rad s-1. No significant changes were observed over the 10-week training period in percentages of type I, IIa and IIb fibres, but both groups showed significant increases (P less than 0.05) in type I and IIa fibre areas.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

9.
《Chronobiology international》2013,30(4-5):645-660
Diurnal variation in muscle performance has been well documented in the past few years, but almost exclusively in the male population. The possible effects of the menstrual cycle on human circadian rhythms have remained equivocal, particularly in the context of muscle strength. The purpose of the study was to analyze the isolated and combined effects of circamensal variation and diurnal changes on muscle strength. Eight eumenorrheic females (age 30 ± 5 yrs, height 1.63 ± 0.06 m and body mass 66.26 ± 4.6 kg: mean ± SD) participated in this investigation. Isokinetic peak torque of knee extensors and flexors of the dominant leg were measured at 1.05, 3.14 rad.s?1 (through 90° ROM) at two times-of-day (06:00, 18:00 h) and five time points of the menstrual cycle (menses, mid-follicular, ovulation, mid-luteal, late luteal). In addition, maximum voluntary isometric contraction of knee extensors and flexors and electrically stimulated isometric contraction of the knee extensors were measured at 60° of knee flexion. Rectal temperature was measured during 30 min before the tests. There was a significant time-of-day effect on peak torque values for isometric contraction of knee extensors under electrical stimulation (P < 0.05). At 18:00 h, muscle force was 2.6% greater than at 06:00 h. The time-of-day effect was not significant when the tests were performed voluntarily without stimulation: effect size calculations indicated small differences between morning and evening for maximal voluntary isometric contraction and peak torque (at 1.05 rad.s?1) for the knee extensors. A circamensal variation was observed for peak torque of knee flexors at 1.05 rad.s?1, extensors at 3.14 rad.s?1, and also isometric contraction of knee flexors, values being greatest at the ovulation phase. Interaction effects between time-of-day and menstrual cycle phase were not observed in any of the indices of muscle strength studied. The phase of the menstrual cycle seemed to have a greater effect than did the time-of-day on female muscle strength in this group of subjects. The present results suggest that peripheral rather than central mechanisms (e.g., motivation) are implicated in the diurnal variation of maximal isometric strength of women.  相似文献   

10.
Diurnal variation in muscle performance has been well documented in the past few years, but almost exclusively in the male population. The possible effects of the menstrual cycle on human circadian rhythms have remained equivocal, particularly in the context of muscle strength. The purpose of the study was to analyze the isolated and combined effects of circamensal variation and diurnal changes on muscle strength. Eight eumenorrheic females (age 30 +/- 5 yrs, height 1.63 +/- 0.06m and body mass 66.26 +/- 4.6kg: mean +/- SD) participated in this investigation. Isokinetic peak torque of knee extensors and flexors of the dominant leg were measured at 1.05, 3.14rad.s(-1) (through 90 degrees ROM) at two times-of-day (06:00, 18:00 h) and five time points of the menstrual cycle (menses, mid-follicular, ovulation, mid-luteal, late luteal). In addition, maximum voluntary isometric contraction of knee extensors and flexors and electrically stimulated isometric contraction of the knee extensors were measured at 60 degrees of knee flexion. Rectal temperature was measured during 30min before the tests. There was a significant time-of-day effect on peak torque values for isometric contraction of knee extensors under electrical stimulation (P< 0.05). At 18:00 h, muscle force was 2.6% greater than at 06:00 h. The time-of-day effect was not significant when the tests were performed voluntarily without stimulation: effect size calculations indicated small differences between morning and evening for maximal voluntary isometric contraction and peak torque (at 1.05rad.s(-1) for the knee extensors. A circamensal variation was observed for peak torque of knee flexors at 1.05rad.s(-1), extensors at 3.14rad.s(-1), and also isometric contraction of knee flexors, values being greatest at the ovulation phase. Interaction effects between time-of-day and menstrual cycle phase were not observed in any of the indices of muscle strength studied. The phase of the menstrual cycle seemed to have a greater effect than did the time-of-day on female muscle strength in this group of subjects. The present results suggest that peripheral rather than central mechanisms (e.g., motivation) are implicated in the diurnal variation of maximal isometric strength of women.  相似文献   

11.
ABSTRACT: Bryanton, MA, Kennedy, MD, Carey, JP, and Chiu, LZF. Effect of squat depth and barbell load on relative muscular effort in squatting. J Strength Cond Res 26(10): 2820-2828, 2012-Resistance training is used to develop muscular strength and hypertrophy. Large muscle forces, in relation to the muscle's maximum force-generating ability, are required to elicit these adaptations. Previous biomechanical analyses of multi-joint resistance exercises provide estimates of muscle force but not relative muscular effort (RME). The purpose of this investigation was to determine the RME during the squat exercise. Specifically, the effects of barbell load and squat depth on hip extensor, knee extensor, and ankle plantar flexor RME were examined. Ten strength-trained women performed squats (50-90% 1 repetition maximum) in a motion analysis laboratory to determine hip extensor, knee extensor, and ankle plantar flexor net joint moment (NJM). Maximum isometric strength in relation to joint angle for these muscle groups was also determined. Relative muscular effect was determined as the ratio of NJM to maximum voluntary torque matched for joint angle. Barbell load and squat depth had significant interaction effects on hip extensor, knee extensor, and ankle plantar flexor RME (p < 0.05). Knee extensor RME increased with greater squat depth but not barbell load, whereas the opposite was found for the ankle plantar flexors. Both greater squat depth and barbell load increased hip extensor RME. These data suggest that training for the knee extensors can be performed with low relative intensities but require a deep squat depth. Heavier barbell loads are required to train the hip extensors and ankle plantar flexors. In designing resistance training programs with multi-joint exercises, how external factors influence RME of different muscle groups should be considered to meet training objectives.  相似文献   

12.
The purpose of this study was to examine the effects of 2 days of isokinetic training of the forearm flexors and extensors on strength and electromyographic (EMG) amplitude for the agonist and antagonist muscles. Seventeen men (mean +/- SD age = 21.9 +/- 2.8 years) were randomly assigned to 1 of 2 groups: (a) a training group (TRN; n = 8), or (b) a control group (CTL; n = 9). The subjects in the TRN group were tested for maximal isometric and concentric isokinetic (randomly ordered velocities of 60, 180, and 300 degrees x s(-1)) torque of the dominant forearm flexors and extensors before (pretest) and after (posttest) 2 days of isokinetic strength training. Each training session involved 6 sets of 10 maximal concentric isokinetic muscle actions of the forearm flexors and extensors at a velocity of 180 degrees x s(-1). The subjects in the CTL group were also tested for strength but did not perform any training. Surface EMG signals were detected from the biceps brachii and triceps brachii muscles during the strength testing. The results indicated that there were no significant (p > 0.05) pre- to post-test changes in forearm flexion and extension torque or EMG amplitude for the agonist and antagonist muscles. Thus, unlike previous studies of the quadriceps femoris muscles, these findings for the forearm flexors and extensors suggested that 2 days of isokinetic training may not be sufficient to elicit significant increases in strength. These results may have implications for the number of visits that are required for rehabilitation after injury, surgery, or both.  相似文献   

13.
Anterior cruciate ligament (ACL) neuromuscular training programs have demonstrated beneficial effects in reducing ACL injuries, yet further evaluation of their effects on biomechanical measures across a sports team season is required to elucidate the specific factors that are modifiable. The purpose of this study was to evaluate the effects of a 10-week off-season neuromuscular training program on lower extremity kinematics. Twelve Division I female soccer players (age: 19.2 ± 0.8 years, height: 1.67 ± 0.1 m, weight: 60.2 ± 6.5 kg) performed unanticipated dynamic trials of a running stop-jump task pretraining and posttraining. Data collection was performed using an 8-camera Vicon system (Los Angeles, CA, USA) and 2 Bertec (Columbus, OH, USA) force plates. The 10-week training program consisted of resistance training 2 times per week and field training, consisting of plyometric, agility, and speed drills, 2 times per week. Repeated measures analyses of variance (ANOVAs) were used to assess the differences between pretraining and posttraining kinetics and kinematics of the hip, knee, and ankle at initial contact (IC), peak knee flexion (PKF), and peak stance. Repeated measures ANOVAs were also used to assess isometric strength differences pretraining and posttraining. The alpha level was set at 0.05 a priori. The training program demonstrated significant increases in left hip extension, left and right hip flexion, and right hip adduction isometric strength. At IC, knee abduction angle moved from an abducted to an adducted position (-1.48 ± 3.65° to 1.46 ± 3.86°, p = 0.007), and hip abduction angle increased (-6.05 ± 4.63° to -10.34 ± 6.83°, p = 0.007). Hip abduction angle at PKF increased (-2.23 ± 3.40° to 6.01 ± 3.82°, p = 0.002). The maximum knee extension moment achieved at peak stance increased from pretraining to posttraining (2.02 ± 0.32 to 2.38 ± 0.75 N·m·kg?1, p = 0.027). The neuromuscular training program demonstrated a potential positive effect in altering mechanics that influence the risk of incurring an ACL injury.  相似文献   

14.
The aim of this study was to determine the power output and work done by different muscle groups at the hip and knee joints during a rising movement, to be able to tell the degree of activation of the muscle groups and the relationship between concentric and eccentric work. Nine healthy male subjects rose from a chair with the seat at knee level. The moments of force about the hip and knee joints were calculated semidynamically. The power output (P) and work in the different muscle groups surrounding the joints was calculated as moment of force times joint angular velocity. Work was calculated as: work = f Pdt. The mean peak concentric power output was for the hip extensors 49.9 W, hip flexors 7.9 W and knee extensor 89.5 W. This power output corresponded to a net concentric work of 20.7 J, 1.0 J and 55.6 J, respectively. There was no concentric power output from the knee flexor muscles. Energy absorption through eccentric muscle action was produced by the hip extensors and hip flexors with a mean peak power output of 4.8 W and 7.4 W, respectively. It was concluded that during rising, the hip and knee muscles mainly worked concentrically and that the greatest power output and work were produced during concentric contraction of the knee and hip extensor muscles. There was however also a demand for eccentric work by the hip extensors as well as both concentric and eccentric work by the hip flexors. The knee flexor muscles were unloaded.  相似文献   

15.
The purposes of this study were to compare the lower-body flexibility, strength, and knee stability of karate athletes against that of non-karate controls and to determine whether regular karate training results in adaptations that may result in an increased risk for knee injury. Flexibility measurements included knee flexion and extension, hip flexion and extension, hip internal and external rotation, and foot inversion and eversion. Nine karate athletes (4 women and 5 men, age = 24.3 +/- 6.7 years) and 15 active, non-karate controls (7 women and 8 men, age = 22.1 +/- 3.2 years) participated. No subjects reported recent knee surgery or chronic or acute knee pain. Concentric quadriceps and hamstrings strength and endurance were measured using a Biodex II isokinetic dynamometer at 60 degrees .s(-1) and 180 degrees .s(-1). Eccentric strength was measured at 150 degrees .s(-1) and 250 ft-lb (339 N.m). Knee stability was measured via varus and valgus stress and anterior drawer testing. Karate athletes demonstrated a significantly greater right hip flexion (p 相似文献   

16.
The aim of this study was to investigate the effects of two different frequencies of whole-body vibration (WBV) training on knee extensors muscle strength in healthy young volunteers. Twenty-two eligible healthy untrained young women aged 22-31 years were allocated randomly to the 30-Hz (n=11) and 50-Hz (n=11) groups. They participated in a supervised WBV training program that consisted of 24 sessions on a synchronous vertical vibration platform (peak-to-peak displacement: 2-4 mm; type of exercises: semi-squat, one-legged squat, and lunge positions on right leg; set numbers: 2-24) three times per week for 8 weeks. Isometric and dynamic strength of the knee extensors were measured prior to and at the end of the 8-week training. In the 30-Hz group, there was a significant increase in the maximal voluntary isometric contraction (p=0.039) and the concentric peak torque (p=0.018) of knee extensors and these changes were significant (p<0.05) compared with the 50-Hz group. In addition, the eccentric peak torque of knee extensors was increased significantly in both groups (p<0.05); however, there was no significant difference between the two groups (p=0.873). We concluded that 8 weeks WBV training in 30 Hz was more effective than 50 Hz to increase the isometric contraction and dynamic strength of knee extensors as measured using peak concentric torque and equally effective with 50 Hz in improving eccentric torque of knee extensors in healthy young untrained women.  相似文献   

17.
The purpose of this study was to document the early history of knee extensor torque production before and after total knee arthroplasty (TKA), explore the relationship between strength assessments, and describe an 8-week resistive-training protocol. Thirty-eight individuals (19 men, 19 women) with unilateral TKA volunteered to participate in this repeated-measures study. For this group, the mean age was 72.23 +/- 5.34 years; height was 168.00 +/- 8.57 cm; and weight was 79.42 +/- 14.57 kg. Torque production of the knee extensors was assessed isokinetically at 60 and 180 degrees .s(-1) before surgery, 30 days after unilateral TKA (+30), and 60 days after unilateral TKA (+60). Torque production was significantly different between limbs at both 60 and 180 degrees .s(-1) (p < 0.0125) before surgery. Torque production was lower at +30 compared with before surgery at both 60 and 180 degrees .s(-1) (p < 0.002). By +60, torque production was greater than at +30 at both 60 and 180 degrees .s(-1) (p < 0.002).  相似文献   

18.
The effects of strength conditioning on skeletal muscle function and mass were determined in older men. Twelve healthy untrained volunteers (age range 60-72 yr) participated in a 12-wk strength training program (8 repetitions/set; 3 sets/day; 3 days/wk) at 80% of the one repetition maximum (1 RM) for extensors and flexors of both knee joints. They were evaluated before the program and after 6 and 12 wk of training. Weekly measurements of 1 RM showed a progressive increase in strength in extensors and flexors. By 12 wk extensor and flexor strength had increased 107.4 (P less than 0.0001) and 226.7% (P less than 0.0001), respectively. Isokinetic peak torque of extensors and flexors measured on a Cybex II dynamometer increased 10.0 and 18.5% (P less than 0.05) at 60 degrees/s and 16.7 and 14.7% (P less than 0.05) at 240 degrees/s. The torque-velocity relationship showed an upward displacement of the curve at the end of training, mainly in the slow-velocity high-torque region. Midthigh composition from computerized tomographic scans showed an increase (P less than 0.01) in total thigh area (4.8%), total muscle area (11.4%), and quadriceps area (9.3%). Biopsies of the vastus lateralis muscle revealed similar increases (P less than 0.001) in type I fiber area (33.5%) and type II fiber area (27.6%). Daily excretion of urinary 3-methyl-L-histidine increased with training (P less than 0.05) by an average 40.8%. Strength gains in older men were associated with significant muscle hypertrophy and an increase in myofibrillar protein turnover.  相似文献   

19.
Coactivation of knee flexors during knee extension assists in joint stability by exerting an opposing torque to the anterior tibial displacement induced by the quadriceps. This opposing torque is believed to be generated by eccentric muscle actions that stiffen the knee, thereby attenuating strain to joint ligaments, particularly the anterior cruciate ligament (ACL). However, as the lengths of knee muscles vary with changes in joint position, the magnitude of flexor/extensor muscle force coupling may likewise vary, possibly affecting the capacity for active knee stabilization. The purpose of this study was to assess the effect of changes in movement speed and joint position on eccentric/concentric muscle action relationships in the knees of uninjured (UNI) and post-ACL-surgery (INJ) subjects (n = 14). All subjects were tested for maximum eccentric and concentric torque of the contralateral knee flexors and extensor muscles at four isokinetic speeds (15 degrees-60 degrees x s(-1)) and four joint position intervals (20 degrees-60 degrees of knee flexion). Eccentric flexor torque was normalized to the percentage of concentric flexor torque generated at each joint position interval for each speed tested (flexor E-C ratio). In order to estimate the capacity of the knee flexors to resist active knee extension, the eccentric-flexor/concentric-extensor ratios were also computed for each joint position interval and speed (flexor/extensor E-C ratio). The results revealed that eccentric torque surpassed concentric torque by 3%-144% across movement speeds and joint position intervals. The magnitude of the flexor E-C ratio and flexor/extensor E-C increased significantly with speed in both groups of subjects (P < 0.05) and tended to rise with muscle length as the knee was extended; peak values were generated at the most extended joint position (20 degrees-30 degrees). Although torque development patterns were symmetrical between the contralateral limbs in both groups, between-group comparisons revealed significantly higher flexor/extensor E-C ratios for the INJ group compared to the UNI group (P < 0.05), particularly at the fastest speed tested (60 degrees x s(-1)). The results indicate that joint position and movement speed influence the eccentric/concentric relationships of knee flexors and extensors. The INJ subjects appeared to accommodate to surgery by developing the eccentric function of their ACL and normal knee flexors, particularly at higher speeds and at more extended knee joint positions. This may assist in the dynamic stabilization of the knee at positions where ACL grafts have been reported to be most vulnerable to strain.  相似文献   

20.
This study assessed the effects of hamstring prefatigue on peak torque, peak power, time to peak torque, knee angle of peak torque, and electromyography (EMG) activity of the hamstrings and quadriceps group during knee extensions at angular velocities of 60 degrees, 180 degrees, and 300 degrees.s(-1). Twenty Division I wrestlers performed 5 maximal knee extensions in prefatigued and nonfatigued conditions of the hamstring group. This study demonstrated that when the hamstrings were prefatigued, the quadriceps produced significant decreases in peak torque of 1.7% (p < 0.05), peak power of 11% (p < 0.05), and rate to peak torque of 6.4% (p < 0.01) as compared with the nonfatigued state. When the hamstrings were prefatigued, they produced a 25% greater amount of EMG activity during knee extension (p < 0.01) than when not prefatigued. There was no significant difference in quadriceps EMG activity whether the hamstring group was prefatigued or not (p > 0.05). The decrease in quadriceps peak torque during the prefatigued condition was more pronounced (p < 0.01) at an angular velocity of 60 degrees.s(-1) than at 180 degrees or 300 degrees.s(-1). In other words, prefatiguing the antagonist appears to be most detrimental to torque output of the quadriceps in the condition that most closely replicates the speed at which "isotonic" weight training occurs (60 degrees.s(-1)) and suggests a limitation to agonist-antagonist superset training.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号