首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple and sensitive column-switching HPLC method was developed for the simultaneous determination of two furocoumarin compounds, byak-angelicin and oxypeucedanin hydrate, which are the main components of hot water extract of Angelica dahurica root (AE), in rat plasma. Plasma sample was simply deproteinated with perchloric acid. After centrifugation, the supernatant was injected into a column-switching HPLC system consisting of a clean-up column (Symmetry Shield RP 8, 20×3.9 mm I.D.) and analytical column (Symmetry C18, 75×4.6 mm I.D.) which were connected with a six-port switching valve. The flow-rate of the mobile phase (acetonitrile–water, 20:80) was maintained at 1 ml/min. Detection was carried out at wavelength 260 nm with a UV detector. The column temperature was maintained at 40°C. The calibration curves of byak-angelicin and oxypeucedanin hydrate were linear over the ranges 19.6 to 980 ng/ml (r2>0.997). The accuracy of these analytes was less than 4.4%. The intra- and inter-day relative standard deviations of byak-angelicin and oxypeucedanin hydrate were within 12.0% and 12.7%, respectively. The present method was applied for the analysis of plasma concentration from rats after administration of AE.  相似文献   

2.
An automated method for simultaneous routine quantification of the antipsychotic drugs clozapine, olanzapine and their demethylated metabolites is described. The method included adsorption on a cyanopropyl (CPS) coated clean-up column (10 μm; 10×2.0 mm I.D.), washing off interfering serum constituents to waste, and separation on C18 ODS Hypersil reversed phase material (5 μm; 250×4.6 mm I.D.) using acetonitrile–water–tetramethylethylenediamine (37:62.6:0.4, v/v/v) adjusted to pH 6.5 with concentrated acetic acid. UV-detection was performed at 254 nm. The limit of quantification was 10–20 ng/ml. Relative day to day standard variations ranged between 4.5 and 13.5%. The method is suitable for routine monitoring of olanzapine and clozapine including their demethylated metabolites.  相似文献   

3.
A high-performance liquid chromatographic method for the simultaneous determination of misonidazole and desmethylmisonidazole in plasma is described. After plasma is deproteinized with methanol and the diluted supernatant is chromatographed on a C18 reversed-phase column, both compounds are quantitated by means of an internal standard. The coefficients of variation of within-day and day-to-day precision are below 5.0% for misonidazole in the concentration range of 25–250 mg/l and below 6.1% for desmethylmisonidazole in the concentration range of 2.5–25.0 mg/l. Calibration curves are linear and an analytical recovery varying from 97.6 to 99.8% is obtained. The detection limits for misonidazole and desmethylmisonidazole in plasma are 1.4 mg/l and 0.7 mg/l, respectively.  相似文献   

4.
A sensitive column-switching high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection was developed for the determination of propiverine in human plasma. Propiverine and internal standard, oxybutynin, were extracted from human plasma that had been made basic with 5N sodium hydroxide into methyl tert-butyl ether. The extracted plasma sample was injected onto the HPLC system consisting of a pretreatment column, a concentrating column, and an analytical column, which were connected with a six-port switching valve. The assay was linear in concentration ranges of 2-200 ng/ml for propiverine in human plasma. This method showed excellent sensitivity (a limit of detection of 0.5 ng/ml), good precision and accuracy. This method is suitable for bioequivalence studies following single dose in healthy volunteers.  相似文献   

5.
A sensitive and selective column-switching semi-microcolumn high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of testosterone and eight of its metabolites (6alpha-, 6beta-, 16alpha-, 16beta-, 7alpha-, 2alpha-, and 2beta-hydroxytestosterone, and androstenedione) in liver microsomes. After incubation for 10 min, testosterone and its metabolites were extracted from the microsomes with ethyl acetate, and the extract was evaporated to dryness. The residue was dissolved in the mobile phase and loaded onto the HPLC system. The analytes were first concentrated in a precolumn and subsequently transferred to the analytical column, where they were separated using linear gradient elution. A UV detector set at 254 nm was used to detect the analytes. This newly developed method clearly separated TES and the metabolites with high resolution and was found to be reproducible with intra- and interday variability of <10.7%. This method has been subsequently used to determine the testosterone hydroxylation activities catalyzed by 15 different recombinant CYP isozymes. The results confirmed the formation of stereoselectively hydroxylated metabolites by each CYP isozyme.  相似文献   

6.
A method based on high-performance liquid chromatography (HPLC) with a diode array detection system was developed and validated aiming at the simultaneous determination of oleuropein (OE) and its metabolites, hydroxytyrosol (HT) and tyrosol (T), in human plasma. These phenolic components are believed to play a vital role in the prevention of coronary artery disease and atherosclerosis. The proposed method includes a clean-up solid-phase extraction procedure (using a C(18) column) with high recovery efficiency (85-100%). The statistical evaluation of the method reveals good linearity, accuracy and reproducibility for all the compounds analyzed with RSD values less than 6.5%, while the detection limit is 50 ng/ml for both OE and T and 75 ng/ml for HT. This assay can be employed in bioavailability studies of olive oil phenolic compounds, thus assisting the evaluation of their pharmacological role.  相似文献   

7.
8.
A novel and highly sensitive method has been developed for the determination of catecholamines [noradrenaline (NA), dopamine (DA), serotonin (5-HT) and their metabolites 5-hydroxyindoleacetic acid (5-HIAA) and homovanillic acid (HVA)] in brain tissue. The method uses isocratic reversed-phase HPLC with amperometric end-point detection. The calibration curve was linear over the range 10–150 pg on-column. The assay limits of detection for NA, DA, 5-HT, 5-HIAA and HVA were 3.8, 3.8, 6.8, 5 and 7.5 pg on-column, respectively. The mean inter- and intra-assay relative standard deviations (RSDs) over the range of the standard curve were less than 5%. The absolute recoveries averaged 99.1%, 99.5%, 97.7%, 99.5% and 98.8% for NA, DA, 5-HT, 5-HIAA and HVA, respectively.  相似文献   

9.
10.
A validated HPLC method for the simultaneous determination of triamcinolone acetonide and hydrocortisone has been established to monitor the plasma levels of the compounds in healthy volunteers following intramuscular (i.m.) administration of triamcinolone acetonide. Plasma (1.0 ml) was extracted with dichloromethane after addition of the internal standard, fluocortolone. The compounds were separated using a LiChrospher RP 18 column and detected by UV absorbance. Specificity, linearity, as well as the repeatability, intermediate precision and accuracy of the method were established. The limit of quantification was 0.6 ng/ml for triamcinolone acetonide (C.V.=8.7%, R.E.=2.6%, n=6) and 2.0 ng/ml for hydrocortisone (C.V.=8.3%, R.E.=2.8%, n=6). Data on the stability of triamcinolone acetonide in human plasma are presented. Recovery of the compounds and the internal standard have been studied. The results of quality control samples (n=126) determined during routine analysis of volunteer samples are described. Plasma levels of triamcinolone acetonide after i.m. administration of 40 mg of triamcinolone acetonide are presented.  相似文献   

11.
Terbutaline is a beta-adrenergic receptor antagonist that acts as a bronchodilator in the treatment of asthma and chronic bronchitis. In the present work, a column-switching high-performance liquid chromatographic method was developed to monitor terbutaline sulphate in dog plasma. The system consists of a C2 pre-column (PC) and a C18 analytical column connected in series via a switching valve. Atenolol was used as the internal standard. Good linearity was achieved in the range of 5-800 ng/ml plasma. The mean intra- and inter-assay variation coefficients for this analysis were 2.3 and 4.7%, respectively. The average recovery for terbutaline was 87.4% from plasma. The mean concentration after three freeze-thaw cycles was 99.4% of the normal value. The analytical sensitivity and accuracy of this assay is adequate for characterisation of the pharmacokinetics of oral administration of terbutaline to dogs and has been successfully used to provide pharmacokinetic data using pulsatile and immediate-release tablets.  相似文献   

12.
Gemcitabine (dFdC) is a pyrimidine antimetabolite with broad spectrum activity against tumors. In this paper, a normal-phase high-performance liquid chromatographic method was developed for the determination of the parent drug (dFdC) and its metabolite (dFdU) in human plasma. The described sample preparation procedure for determination of dFdC and dFdU is rapid, sensitive, reproducible and simple. The linear regression equations obtained by least square regression method, were area under the curve=0.0371 concentration (ng ml(-1))+192.53 and 1.05.10(-4) concentration (ng ml(-1))-1.2693 for dFdC and dFdU, respectively. The assay for dFdC and dFdU described in the present report has been applied to plasma samples from a bladder cancer patient.  相似文献   

13.
14.
A column-switching high-performance liquid chromatographic analysis was established to monitor the serum concentration of mycophenolic acid, the active metabolite from mycophenolate mofetil administered for the prophylaxis of acute organ rejection in renal transplantation. The system consisted of two pumps for solvent delivery, a column-switching valve, a precolumn, and a reversed-phase analytical column. The present method enabled us to determine MPA by injecting serum samples directly into HPLC without any pretreatment. The mobile phases with different amounts of organic solvent were delivered to the precolumn and analytical column by separate lines, and samples were applied to the precolumn. The column switching valves were switched automatically following the processes for the elimination of protein and the drug analysis. The peak heights of MPA were linearly related to the concentrations (r=0.999) in the range of 0.1-20 micro g/ml, and the limit of quantification was 0.1 micro g/ml (S/N ratio=3). This method was accurate and reproducible on the basis of the results of recovery (94.0-98.0%) and small coefficient of variations of intra and inter-assay (less than 8.3%).  相似文献   

15.
A method for the simultaneous determination of bile acids in rat liver tissue by high-performance liquid chromatography was developed. Without prior fractionation and alkaline hydrolysis, 30 unconjugated, glycine- and taurine-conjugated bile acids were detected by post-column enzymatic reaction and fluorescence detection. They were separated on a reversed-phase column using a linear gradient solvent system of 10 mM tribasic ammonium phosphate–acetonitrile–methanol (44:12:5, v/v/v) and 20 mM dibasic ammonium phosphate–acetonitrile–methanol (2:1:2, v/v/v). The limits of detection were 1–5 pmol, and calibration curves were linear for concentrations ranging between 10 and 4000 pmol per 10 μl injection. This rapid and reliable method is effective for measuring bile acid levels in liver tissue not only of rats but also of patients with hepatobiliary and other diseases.  相似文献   

16.
A simple and sensitive column-switching HPLC method has been developed for the simultaneous determination of NK-104 (HMG–CoA reductase inhibitor) and its lactone in human and dog plasma. Plasma sample was extracted with methyl tert-butyl ether and then the extract was subjected to methylation with diazomethane to prevent the mutual conversion between NK-104 and its lactone. The extract was injected into the column-switching HPLC system. The calibration curves of NK-104 and NK-104 lactone were linear over the ranges 0.5 to 100 ng/ml for human plasma samples and 0.5 to 500 ng/ml for dog plasma, respectively. The intra-day and inter-day C.V. values of these analytes were less than 13.3%. The intra-day and inter-day accuracies of these analytes were between −14.0 and 6.5%. The proposed method has been applied to plasma samples obtained after oral administration of a single 2 mg dose of NK-104 to volunteers.  相似文献   

17.
This study describes a new simultaneous determination of haloperidol and bromperidol and their reduced metabolites by modification of automated column-switching high-performance liquid chromatography. The test compounds were extracted from 1ml of plasma using chloroform-hexane (30:70 (v/v)), and the extract was injected into a hydrophilic metaacrylate polymer column for clean-up and a C(18) analytical column for separation. The mobile phases consisted of phosphate buffer (0.02M, pH 4.6), perchloric acid (60%) and acetonitrile (54:1:45 (v/v)) and was delivered at a flow-rate of 0.6ml/min. The peak was detected using a UV detector set at 215nm. The method was validated for the concentration range 1-100ng/ml, and good linearity (r >0.999) was confirmed. Intra-day coefficient variations (CVs) for haloperidol, reduced haloperidol, bromperidol and reduced bromperidol were less than 2.5, 3.1, 2.4 and 2.5%, respectively. Inter-day CVs for corresponding compounds were 3.9, 5.1, 2.6 and 4.4%, respectively. Relative errors ranged from -5 to 10% and mean recoveries were 96-100%. The limit of quantification was 1.0ng/m for each compound. This method shows good specificity with respect to commonly prescribed psychotropic drugs, and it could be successfully applied for pharmacokinetic studies and therapeutic drug monitoring, particularly in patients receiving both haloperidol and bromperidol.  相似文献   

18.
It has been suggested that GTS-21 can improve the learning deficits and inhibit the neuro-degeneration in patients with Alzheimer's disease. This paper describes a reversed-phase high-performance liquid chromatographic assay with visible detection at 405 nm for determination of GTS-21 and its metabolite, 4-hydroxy-GTS-21 in rat plasma. The method uses solid-phase extraction with a Bond Elut C18 column. A quantitation limit of 1.0 ng/ml was achieved using 0.5 ml of rat plasma. In the validation study, the coefficients of variation and the relative errors of each compound were less than 10%. Also freeze-thaw and storage stability were confirmed. This method has proved to be applicable to the pharmacokinetic study of GTS-21 in rats.  相似文献   

19.
A simple reversed-phase high-performance liquid chromatographic method has been developed for the simultaneous determination of theophylline, ciprofloxacin and enoxacin in plasma and saliva. The biological fluid samples were extracted with methylene chloride-isopropyl alcohol prior to isocratic chromatography on a Waters C18 μBondapak column. Ultraviolet detection was carried out at 268 nm. The assay in linear for ciprofloxacin and enoxacin (0.05–10 μg/ml), and theophylline (0.1–20 μ/ml). The assay can be used to investigate the interaction of these two fluoroquinolones with theophylline.  相似文献   

20.
A high-performance liquid chromatographic method was developed for the simultaneous determination of phenylbutazone and its metabolites, oxyphenbutazone and γ-hydroxyphenylbutazone, in plasma and urine. Samples were acidified with hydrochloric acid and extracted with benzene—cyclohexane (1:1, v/v). The extract was redissolved in methanol and chromatographed on a μBondapak C15 column using a mobile phase of methanol—0.01 M sodium acetate buffer (pH 4.0) in a linear gradient (50 to 100% methanol at 5%/min; flow-rate 2.0 ml/min) in a high-performance liquid chromatograph equipped with an ultra-violet absorbance detector (254 nm). The detection limit for phenylbutazone, oxyphenbutazone and for γ-hydroxyphenylbutazone was 0.05 μg/ml.A precise and sensitive assay for the determination of phenylbutazone and its metabolites was established.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号