首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple HPLC method has been described to quantify diquat in biological fluids and tissues. This method permits separation and quantification of diquat from blood, bile, urine, liver and kidney. It does not require special pretreatment of the samples prior to analysis, nor a specially prepared analytical column. Various concentrations of diquat were added (10–300 nmol/ml or g) to fluids or tissues. Analysis of blank samples revealed no substrates that interfere with diquat elution. Excellent recovery (95–105%) was obtained. Diquat (120 μmol/kg, i.v.) was injected to rats and quantified in bile, blood and liver. Concentration of diquat was higher in blood and bile than liver. Therefore, this method is applicable for quantification of diquat in toxicological samples, and may be used to determine structurally similar compounds such as paraquat.  相似文献   

2.
A fluorescent labelling reagent, 3-(5,6-methylenedioxy-2-phthalimidyl)benzoyl azide, designed for the determination of alcohols by precolumn high-performance liquid chromatography, has been applied to the simultaneous determination of cholesterol and cholestanol in human serum. The reagent reacts with cholesterol and cholestanol at 140°C for 10 min to produce the fluorescent derivatives, which can be separated on a reversed-phase column with acetonitrile—ethanol—water (60:35:7.5, v/v) as eluent. The detection limits for cholesterol and cholestanol were 45 and 50 fmol per injection (20 μl), respectively. The values of cholesterol and cholestanol in normal human sera were 135–212 mg/dl and 137–928 μg/dl, respectively.  相似文献   

3.
A rapid, selective and reproducible high-performance liquid chromatographic (HPLC) method with ultraviolet detection was developed for the determination of the anti-cancer agent Taxotere in biological fluids. The method involves a solid-phase extraction step (C2 ethyl microcolumns) using a Varian Advanced Automated Sample Processor (AASP) followed by reversed-phase HPLC. The validated quantitation range of the method is 10–2500 ng/ml in plasma with coefficients of variation ≤ 11%. The method is also suitable for the determination of Taxotere in urine samples under the same conditions. The method was applied in a phase I tolerance study of Taxotere in cancer patients, allowing the pharmacokinetic profile of Taxotere to be established.  相似文献   

4.
A fully automated analytical system based on liquid—solid extraction combined with column liquid chromatography is described for the determination of diclofenac in plasma. After addition of pH 5 buffer and the internal standard solution to the plasma sample, both sample preparation via a C18 disposable extraction column and injection were performed by a Gilson ASPEC system. Diclofenac and the internal standard were separated on a reversed-phase column, using methanol—pH 7.2 phosphate buffer (56:44, v/v) as mobile phase at a flow-rate of 0.4 ml/min. The reproducibility and accuracy of the method were acceptable over the concentration range 31–3140 nmol/l in plasma.  相似文献   

5.
A fluorescence high-performance liquid chromatographic method is described for the direct determination of conjugated 17-oxosteroids in biological fluids without hydrolysis. Conjugated 17-oxosteroids are extracted with Sep-Pak C18 cartridge, labeled with dansyl hydrazine in trichloroacetic acid—benzene solution and then separated by high-performance liquid chromatography on reversed-phase μBondapak C18 column using 0.01M sodium acetate in methanol—water—acetic acid (65:35:1, v/v) as the mobile phase. The eluate is monitored by a fluorophotometer at 365 nm (excitation) and 520 nm (emission). Linearities of fluorescence intensities (peak heights) with the amounts of various conjugated 17-oxosteroids were obtained between 10 pmol and 100 pmol. This method is sensitive, reliable and useful for the simultaneous determination of conjugated 17-oxosteroids in urine and serum.  相似文献   

6.
A high-performance liquid chromatographic (HPLC) method with ultraviolet detection for the determination of quinine in rat biological fluids is described. Due to its selectivity and sensitivity, the proposed method can be used in the case of such rat biological fluids as cerebrospinal fluid (CSF) and perilymph for which the accessible volumes are limited to 100 μl and 10 μl, respectively. Consequently, the assay method has been applied to the measurements of quinine concentration in rat plasma, CSF and perilymph samples.  相似文献   

7.
An improved method for the determination of catecholamines in biological fluids, by reversed-phase high-performance liquid chromatography (HPLC) with fluorimetric detection is presented. The pH titration previously employed in the alumina extraction was abandoned in favour of the use of a molar excess of pH 8.5 Tris—HCl buffer. A novel lyophilisation step serves to concentrate the catechols and by reconstituting in mobile phase, chromatography disturbances are minimised. The addition of 2 mM octanesulphonic acid to a citrate—phosphate mobile phase at pH 6.0 gave optimal resolution and sensitivity.That HPLC separation can improve the specificity of the trihydroxyindole reaction, to the extent of providing a reliable analytical method, has been demonstrated and validated by the technique of HPLC with electrochemical detection. A correlation coefficient of 0.98 was obtained between the two techniques as applied to the measurement of urinary catecholamines. The HPLC—fluorimetric method was sensitive enough to measure 0.1 ng/ml of noradrenaline or adrenaline at a signal-to-noise ratio of 2.0. Application of the method to the quantitative determination of catecholamines in human urine, plasma and rat brain homogenates is demonstrated.  相似文献   

8.
An HPLC method has been developed for the separation and the determination of caffeine and its metabolites in urine samples using a one extraction–analysis run and UV detection. The compounds were extracted by liquid–liquid extraction using chloroform–isopropylalcohol (85:15, v/v). Chromatographic separation was accomplished on an ODS analytical column with a mobile phase containing 0.05% acetic acid/methylalcohol (92.5:7.5, v/v). Compounds were monitored at 280 nm. The method was validated for the determination of AFMU, 1X, 1U, 17X and 17U caffeine metabolites required to assess the metabolic activity of the enzymes subject to in vivo caffeine testing. The validated assay was applied to urine samples from ten healthy volunteers. The method was proved to be suitable to assess simultaneously the enzymatic activity of cytochrome P450 CYP1A2 and CYP2A6, as well as N-acetyltransferase and xanthine oxidase.  相似文献   

9.
Production of cholesterol oxidase by a newly isolated Rhodococcus sp.   总被引:1,自引:0,他引:1  
Fifteen strains of microorganisms with ability to degrade cholesterol were isolated. Among them a Gram-positive, non-motile, non-sporing bacterium with meso-DAP in the cell wall and with a rod-coccus cycle showed the highest ability for cholesterol degradation. It was identified as Rhodococcus sp. strain 2C and was deposited by code 1633 in Persian type culture collection (PTCC). This strain was able to produce high levels of both extracellular and cell-bound cholesterol oxidases in media containing cholesterol as a sole carbon source. The effects of medium composition and physical parameters on cholesterol oxidase production were studied. The optimized medium was found to contain cholesterol 0.15% (w/v), yeast extract 0.3% (w/v), diammonium hydrogen phosphate 0.1% (w/v), Tween 80 (0.05%). The optimum pH and temperature for cholesterol oxidase production in optimized medium were found to be 8–30 °C respectively. Triton X-100 showed the greatest effect in releasing the cell-bound enzyme. The first and most probably the main metabolite of cholesterol degradation was purified and identified as 4-cholestene-3-one.  相似文献   

10.
A rapid and sensitive method for the assay of zonisamide in serum was developed using a solid-phase extraction technique followed by high-performance liquid chromatography. A 20-μl volume of human serum was first purified with a Bond-Elut cartridge column. Then, the methanol eluate was injected onto a reversed-phase HPLC column with a UV detector. The mobile phase was acetonitrile—methanol—distilled water (17:20:63, v/v) and the detection wavelength was 246 nm. The detection limit was 0.1 μg/ml in serum. The coefficients of variation were 4.2–5.6% and 5.1–9.1% for the within-day and between-day assays, respectively. This method can be used for clinical pharmacokinetic studies of zonisamide in serum even in infant patients with epilepsy.  相似文献   

11.
A high-performance liquid chromatographic (HPLC) procedure has been developed for the quantification of L-365,260 (I), a cholecystokinin and gastrin receptor antagonist, in dog and rat plasma. The method involves liquid—liquid extraction and HPLC with ultraviolet detection. Standard curves were linear over the range 7.5–2000 ng/ml for rat and dog plasma. The method is reproducible and reliable with a detection limit of 7.5 ng/ml in biological fluids. The mean coefficients of variation for concentrations within the range of the standard curve range were 3.84 and 2.56%, respectively, for intra-day analysis and 4.48 and 4.26%, respectively, for inter-day analysis. Application of the development was successfully demonstrated by quantifying the concentration of I in both dog and rat plasma samples following an intravenous or oral dose of 5 mg/kg I.  相似文献   

12.
A high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of aspirin and salicylic acid in transdermal perfusates. The compounds were separated on a C8 Nucleosil column (5 μm, 250×4.6 mm) using a mobile phase containing a mixture of water–acetonitrile–orthophosphoric acid (650:350:2, v/v/v) and a flow-rate of 1 ml/min. The transdermal samples were in phosphate-buffered saline (PBS) and could be injected directly onto the HPLC system. The method was reproducible with inter-day R.S.D. values of no greater than 3.46 and 2.60% for aspirin and salicylic acid, respectively. The method was linear over the concentration range 0.2–5.0 μg/ml and had a limit of detection of 0.05 μg/ml for both compounds. For certain samples, it was necessary to ensure that no transmembrane leakage of the aspirin prodrugs had occurred. In these cases, a gradient was introduced by increasing the acetonitrile content of the mobile phase after the salicylic acid had eluted. The method has been applied to the determination of aspirin and salicylic acid in PBS following in vitro application of the compounds to mouse skin samples.  相似文献   

13.
Ambroxol has been determined in biological fluids using a rapid and sensitive high-performance liquid chromatographic method. The samples prepared from plasma by liquid—liquid extraction were analysed on reversed-phase silica gel by competing-ion chromatography with ultraviolet detection. The method was applied to the determination of ambroxol levels in twelve healthy volunteers after oral administration of 90 mg of ambroxol in tablets of Mucosolvan and Ambrosan.  相似文献   

14.
A sensitive high-performance liquid chromatographic (HPLC) method for the quantitation of famotidine in human plasma is described. Clopamide was used as the internal standard. Plasma samples were extracted with diethyl ether to eliminate endogenous interferences. Plasma samples were then extracted at alkaline pH with ethyl acetate. Famotidine and the internal standard were readily extracted into the organic solvent. After evaporation of ethyl acetate, the residue was analysed by HPLC. The chromatographic separation was accomplished with an isocratic mobile phase consisting of acetonitrile—water (12:88, v/v) containing 20 mM disodium hydrogenphosphate and 50 mM sodium dodecyl sulphate, adjusted to pH 3. The HPLC microbore column was packed with 5 μm ODS Hypersil. Using ultraviolet detection at 267 nm, the detection limit for plasma famotidine was 5 ng/ml. The calibration curve was linear over the concentration range 5–500 ng/ml. The inter- and intra-assay coefficients of variation were found to be less than 10%. Applicability of the method was demonstrated by a bioavailability/pharmacokinetic study in normal volunteers who received 80 mg famotidine orally.  相似文献   

15.
A relatively simple reversed-phase high-performance liquid chromatographic method for the determination of the polar metabolites of nifedipine in biological fluids is described. After conversion of 2-hydroxymethyl-6-methyl-4-(2-nitrophenyl)pyridine-3,5-dicarboxylic acid 5-methyl ester (IV) into 5,7-dihydro-2-methyl-4-(2-nitrophenyl)-5-oxofuro[3,4-b]pyridine-3-carboxylic acid methyl ester (V) by heating under acidic conditions, V was extracted with n-pentane—dichloromethane (7:3) and analysed on a C18 column with ultraviolet detection. Subsequently, 2,6-dimethyl-4-(2-nitrophenyl)-3,5-pyridinedicarboxylic acid monomethyl ester (III) was extracted with chloroform and analysed on the same system. Limits of determination in blood were 0.1 μg/ml for III and 0.05 μg/ml for IV and V; these limits were two to ten times higher for urine. This inter-assay variability was always less than 7.5%.  相似文献   

16.
A rapid, sensitive and selective high-performance liquid chromatographic (HPLC) assay was developed for the determination of cibenzoline (Cipralan TM) in human plasma and urine. The assay involves the extraction of the compound into benzene from plasma or urine buffered to pH 11 and HPLC analysis of the residue dissolved in acetonitrile---phosphate buffer (0.015 mol/1, pH 6.0) (80:20). A 10-μ ion-exchange (sulfonate) column was used with acetonitrile—phosphate buffer (0.015 mol/1, pH 6.0) (80:20) as the mobile phase. UV detection at 214 nm was used for quantitation with the di-p-methyl analogue of cibenzoline as the internal standard.The recovery of cibenzoline in the assay ranged from 60 to 70% and was validated in human plasma and urine in the concentration range of 10–1000 ng/ml and 50–5000 ng/ml, respectively. A normal-phase HPLC assay was developed for the determination of the imidazole metabolite of cibenzoline. The assays were applied to the determination of plasma and urine concentrations of cibenzoline and trace amounts of its imidazole metabolite following oral administration of cibenzoline succinate to two human subjects.  相似文献   

17.
Radioimmunoassay (RIA) is the most prevalent method for measuring small amounts of hormones, peptides, and other compounds in human body fluids. The method, however, has several problems, such as cross reactions or non-specific reactions of the antibody used. In order to establish an improved method for assaying dehydroepiandrosterone sulfate (DHEAS) and cholesterol, which are the largest components of human breast cyst and duct fluids, we describe a simple, accurate, and sensitive method using high-performance liquid chromatography (HPLC). The samples were treated with cholesterol oxidase for quantitation of dehydroepiandrosterone (DHEA) and free cholesterol, and the respective oxidized substances, 4-androstene-3,17-dione and 4-cholesten-3-one, were extracted with n-hexane. The extracts were analyzed by straight phase HPLC. Effluents were monitored by measuring absorption at 240 nm, where a newly introduced chromophoric group, an alpha,beta-unsaturated ketone, showed intense absorption (epsilon = 16,000). When the total amount of DHEA (DHEAS plus DHEA) was measured, the sample had been solvolyzed by sulfatase beforehand. The amounts of DHEAS were quantified by comparing the amounts of DHEA before and after solvolysis. Levels of free cholesterol, DHEAS, and DHEA in human breast cyst fluids (n = 30) were 1.77 +/- 1.12 mmol/dl, 8.27 +/- 10.24 micromol/dl, and 0.02 +/- 0.02 micromol/dl (means +/- SD), respectively. The levels of sterol and steroid measured in breast duct fluids that were turbid, brown, dark green, or milky in color (n = 9) (mean levels, 3.20 +/- 2.97 mmol/dl for free cholesterol and 14.77 +/- 13.75 micromol/dl for DHEAS) were significantly (P < 0.01) higher than the levels in clear or serous breast fluids (n = 21) (mean levels, 0.14 +/- 0.13 mmol/dl for free cholesterol and 0.04 +/- 0.07 micromol/dl for DHEAS).  相似文献   

18.
A simple, sensitive and selective method for the determination of budesonide in bronchoalveolar lavage (BAL) using high-performance liquid chromatography (HPLC) with UV detection was developed. BAL samples were extracted twice with methylene chloride, the extracts were centrifuged and the organic laeer separated and dried under nitrogen. The samples were reconstituted in the mobile phase and 80 μl were injected on to a Spherisorb ODS column with UV absorbance detection at 250 nm. The mobile phase was methanol-aqueius buffer (69:31, v/v). Inter-assay coefficients of variation were measured at 7.81 and 500 ng/ml with ranges of 0.89–7.31%. Average recoveries were 97% or greater. This method was successfully implemented for the analysis of BAL from asthmatics, in order to establish the amount of budesonide available to the lung and to investigate the efficacy of inhaler systems. Patients (n = 9) inhaled four puffs of 200 μg of budesonide and BAL was perforned 10 min after the last inhalation. Only four BAL out of the nine presented detectable amounts of budesonide. The concentrations in BAL in these four patients were 13.44–84.18 ng/ml, corresponding to total anounts of 0.847–7.997 μg.  相似文献   

19.
A high-performance liquid chromatographic method for the determination of nitrite and nitrate anions derived from nitric oxide in biological fluids is presented. After separation on a strong anion-exchange column (Spherisorb SAX, 250×4.6 mm I.D., 5 μm), two on-line post-column reactions occur. The first involves nitrate reduction to nitrite on a copper-plated cadmium-filled column. In the second, the diazotization-coupling reaction between nitrite and the Griess reagent (0.05% naphtylethylendiamine dihydrochloride plus 0.5% sulphanilamide in 5% phosphoric acid) takes place, and the absorbance of the chromophore is read at 540 nm. This methodology was applied to biological fluids. Before injection into the chromatographic system, the samples were diluted and submitted to suitable clean-up procedures (urine and cell culture supernatant samples are passed through C18 cartridges, and serum samples were deproteinized by ultrafiltration through membranes with a molecular mass cut-off of 3000). The method has a sensitivity of 30 pmol for both anions, as little as 0.05–0.1 ml sample volume is required and linearity is observed up to 60 nmol for each anion.  相似文献   

20.
A sensitive and selective gas chromatographic assay method employing splitless injection, fused-silica capillary columns and electron-capture detection is reported for the quantitation of the tocolytic drug, ritodrine, in a variety of biological fluids obtained from the pregnant ewe and fetus. This method has improved sensitivity and selectivity over previously published assay procedures. A 25 m × 0.31 mm I.D., cross-linked 5% phenylmethylsilicone, fused-silica capillary column was employed for all analyses. Linearity of response was observed over the range 2.5–75 ng of ritodrine base per 0.05–0.5 ml of biological fluid, representing ≈ 1–75 pg at the detector. The coefficient of variation was less than 10% over the range 2.5–75 ng of added ritodrine. The minimum quantifiable amounts is ≈ 2.5 ng from a 0.5-ml biological fluid sample. Applicability of this method to biological fluids, obtained from ovine subjects, is demonstrated by the analysis of samples obtained during the course of ritodrine placental transfer studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号