首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Microarrays are used to study gene expression in a variety of biological systems. A number of different platforms have been developed, but few studies exist that have directly compared the performance of one platform with another. The goal of this study was to determine array variation by analyzing the same RNA samples with three different array platforms. Using gene expression responses to benzo[a]pyrene exposure in normal human mammary epithelial cells (NHMECs), we compared the results of gene expression profiling using three microarray platforms: photolithographic oligonucleotide arrays (Affymetrix), spotted oligonucleotide arrays (Amersham), and spotted cDNA arrays (NCI). While most previous reports comparing microarrays have analyzed pre-existing data from different platforms, this comparison study used the same sample assayed on all three platforms, allowing for analysis of variation from each array platform. In general, poor correlation was found with corresponding measurements from each platform. Each platform yielded different gene expression profiles, suggesting that while microarray analysis is a useful discovery tool, further validation is needed to extrapolate results for broad use of the data. Also, microarray variability needs to be taken into consideration, not only in the data analysis but also in specific probe selection for each array type.  相似文献   

2.
In two-colour microarrays, the ratio of signal intensities of two co-hybridized samples is used as a relative measure of gene expression. Ratio-based analysis becomes complicated and inefficient in multi-class comparisons. We therefore investigated the validity of an intensity-based analysis procedure. To this end, two different cRNA targets were hybridized together, separately, with a common reference and in a self-self fashion on spotted 65mer oligonucleotide microarrays. We found that the signal intensity of the cRNA targets was not influenced by the presence of a target labelled in the opposite colour. This indicates that targets do not compete for binding sites on the array, which is essential for intensity-based analysis. It is demonstrated that, for good-quality arrays, the correlation of signal intensity measurements between the different hybridization designs is high (R > 0.9). Furthermore, ratio calculations from ratio- and intensity-based analyses correlated well (R > 0.8). Based on these results, we advocate the use of separate intensities rather than ratios in the analysis of two-colour long-oligonucleotide microarrays. Intensity-based analysis makes microarray experiments more efficient and more flexible: It allows for direct comparisons between all hybridized samples, while circumventing the need for a reference sample that occupies half of the hybridization capacity.  相似文献   

3.
We compared different hybridization conditions of oligonucleotide-based DNA microarray to acquire optimized and reliable microarray data. Several parameters were evaluated at different hybridization conditions, including signal-to-background (S:B) ratios, signal dynamic range, usable spots, and reproducibility. Statistical analysis showed that better results were obtained when spotted, presynthesized long oligonucleotide arrays were blocked with succinic anhydride and hybridized at 42°C in the presence of 50% formamide.  相似文献   

4.

Background

DNA microarrays are widely used in gene expression analyses. To increase throughput and minimize costs without reducing gene expression data obtained, we investigated whether four mRNA samples can be analyzed simultaneously by applying four different fluorescent dyes.

Results

Following tests for cross-talk of fluorescence signals, Alexa 488, Alexa 594, Cyanine 3 and Cyanine 5 were selected for hybridizations. For self-hybridizations, a single RNA sample was labelled with all dyes and hybridized on commercial cDNA arrays or on in-house spotted oligonucleotide arrays. Correlation coefficients for all combinations of dyes were above 0.9 on the cDNA array. On the oligonucleotide array they were above 0.8, except combinations with Alexa 488, which were approximately 0.5. Standard deviation of expression differences for replicate spots were similar on the cDNA array for all dye combinations, but on the oligonucleotide array combinations with Alexa 488 showed a higher variation.

Conclusion

In conclusion, the four dyes can be used simultaneously for gene expression experiments on the tested cDNA array, but only three dyes can be used on the tested oligonucleotide array. This was confirmed by hybridizations of control with test samples, as all combinations returned similar numbers of differentially expressed genes with comparable effects on gene expression.  相似文献   

5.
DNA microarray technology has been widely used to simultaneously determine the expression levels of thousands of genes. A variety of approaches have been used, both in the implementation of this technology and in the analysis of the large amount of expression data. However, several practical issues still have not been resolved in a satisfactory manner, and among the most critical is the lack of agreement in the results obtained in different array platforms. In this study, we present a comparison of several microarray platforms [Affymetrix oligonucleotide arrays, custom complementary DNA (cDNA) arrays, and custom oligo arrays printed with oligonucleotides from three different sources] as well as analysis of various methods used for microarray target preparation and the reference design. The results indicate that the pairwise correlations of expression levels between platforms are relative low overall but that the log ratios of the highly expressed genes are strongly correlated, especially between Affymetrix and cDNA arrays. The microarray measurements were compared with quantitative real-time-polymerase chain reaction (QRT-PCR) results for 23 genes, and the varying degrees of agreement for each platform were characterized. We have also developed and tested a double amplification method which allows the use of smaller amounts of starting material. The added round of amplification produced reproducible results as compared to the arrays hybridized with single round amplified targets. Finally, the reliability of using a universal RNA reference for two-channel microarrays was tested and the results suggest that comparisons of multiple experimental conditions using the same control can be accurate.  相似文献   

6.
Microarray-based comparative genomic hybridization has become a widespread method for the analysis of DNA copy number changes across the human genome. Initial methods for microarray construction using large-insert clones required the preparation of DNA from large-scale cultures. This rapidly became an expensive and time-consuming process when expanded to the number of clones needed for higher resolution arrays. To overcome this problem, several PCR-based strategies have been developed to enable array construction from small amounts of cloned DNA. Here, we describe the construction of microarrays composed of human-specific large-insert clones (40-200 kb) using a specific degenerate oligonucleotide PCR strategy. In addition, we also describe array hybridization using manual and automated procedures and methods for array analysis. The technology and protocols described in this article can easily be adapted for other species dependent on the availability of clone libraries. According to our protocols, the procedure will take approximately 3 days from labeling the DNA to scanning the hybridized slides.  相似文献   

7.
Dual-channel long oligonucleotide microarrays are in widespread use. Although much attention has been given to proper experimental design and analysis regarding long oligonucleotide microarrays, relatively little information is available concerning the optimization of protocols. We carried out a series of microarray experiments designed to investigate the effects of different levels of target concentration and hybridization times using a long oligonucleotide library. Based on principles developed from nucleic acid renaturation kinetics studies, we show that increasing the time of hybridization from 18 h to 42 h and 66 h, especially when lower than optimal concentrations of target were used, significantly improved the quality of the microarray results. Longer hybridization times significantly increased the number of spots detected, signal-to-noise ratios, and the number of differentially expressed genes and correlations among replicate arrays. We conclude that at 18 h of incubation, target-to-probe hybridization has not reached equilibrium and that a relatively high proportion of nonspecific hybridization occurs. This result is striking, given that most, if not all, published microarray protocols stipulate 8-24 h for hybridization. Using shorter than optimal hybridization times (i.e., not allowing hybridization to reach equilibrium) has the consequence of underestimating the fold change of differentially expressed genes and of missing less represented sequences.  相似文献   

8.
Microarrays have rapidly become an indispensable tool for gene analysis. Microarray experiments can be cost prohibitive, however, largely due to the price of the arrays themselves. Whilst different methods for stripping filter arrays on membranes have been established, only very few protocols are published for thermal and chemical stripping of microarrays on glass. Most of these protocols for stripping microarrays on glass were developed in combination with specific surface chemistry and different coatings for covalently immobilizing presynthesized DNA in a deposition process. We have developed a method for stripping commercial in situ microarrays using a multi-step procedure. We present a method that uses mild chemical degradation complemented by enzymatic treatment. We took advantage of the differences in biochemical properties of covalently linked DNA oligonucleotides on in situ synthesized microarrays and the antisense cRNA hybridization probes. The success of stripping protocols for microarrays on glass was critically dependent on the type of arrays, the nature of sample used for hybridization, as well as hybridization and washing conditions. The protocol employs alkali hydrolysis of the cRNA, several enzymatic degradation steps using RNAses and Proteinase K, combined with appropriate washing steps. Stripped arrays were rehybridized using the same protocols as for new microarrays. The stripping method was validated with microarrays from different suppliers and rehybridization of stripped in situ arrays yielded comparable results to hybridizations done on unused, new arrays with no significant loss in precision or accuracy. We show that stripping of commercial in situ arrays is feasible and that reuse of stripped arrays gave similar results compared to unused ones. This was true even for biological samples that show only slight differences in their expression profiles. Our analyses indicate that the stripping procedure does not significantly influence data quality derived from post-primary hybridizations. The method is robust, easy to perform, inexpensive, and results after reuse are of comparable accuracy to new arrays.  相似文献   

9.
Human microarrays are readily available, and it would be advantageous if they could be used to study gene expression in other species, such as pigs. The objectives of this research were to validate the use of human microarrays in the analysis of porcine gene expression, to assess the variability of the data generated, and to compare gene expression in boars with different levels of steroidogenesis. Cytochrome b5 (CYB5) expression was used to assess array detection sensitivity. Samples having high or low CYB5 RNA levels were hybridized to microarrays to determine if the known expression difference could be detected. Six hybridizations were conducted using human microarrays containing 3840 total spots representing 1718 characterized human ESTs. To analyze gene expression in boars with different levels of steroidogenesis, testis RNA from four boars with high levels of plasma estrone sulphate was hybridized to testis RNA from four boars with lower levels. Eight microarray hybridizations were conducted including fluor-flips. Self-self hybridizations were also conducted to assess the variability of array experiments. The Cy5 and Cy3 intensity values for each array were normalized using a locally weighted linear regression (LOESS). Statistical significance was assessed using a Student's t-test followed by the Benjamini and Hochberg multiple testing correction procedure. Quantitative real-time PCR (Q-RT-PCR) was used to verify select gene expression differences. The results show that CYB5 was significantly overexpressed in the high CYB5 sample by 1.8 fold (P < 0.05), verifying the known expression difference. The average log2 ratio of the majority of genes (1643) falls within one standard deviation of the mean, indicating the data were reproducible. In the high versus low steroidogenesis experiment, seven genes were significantly overexpressed in the high group (P < 0.05). Quantitative real-time PCR was used to validate five genes with the highest fold change, and the results corroborated those found by the microarray experiments. The results of the self-self hybridizations showed that no genes were significantly differentially expressed following the application of the Benjamini and Hochberg multiple testing correction procedure. The results presented in this report show that human arrays can be used for gene expression analysis in pigs.  相似文献   

10.
Human microarrays are readily available, and it would be advantageous if they could be used to study gene expression in other species, such as pigs. The objectives of this research were to validate the use of human microarrays in the analysis of porcine gene expression, to assess the variability of the data generated, and to compare gene expression in boars with different levels of steroidogenesis. Cytochrome b5 (CYB5) expression was used to assess array detection sensitivity. Samples having high or low CYB5 RNA levels were hybridized to microarrays to determine if the known expression difference could be detected. Six hybridizations were conducted using human microarrays containing 3840 total spots representing 1718 characterized human ESTs. To analyze gene expression in boars with different levels of steroidogenesis, testis RNA from four boars with high levels of plasma estrone sulphate was hybridized to testis RNA from four boars with lower levels. Eight microarray hybridizations were conducted including fluor-flips. Self-self hybridizations were also conducted to assess the variability of array experiments. The Cy5 and Cy3 intensity values for each array were normalized using a locally weighted linear regression (LOESS). Statistical significance was assessed using a Student's t-test followed by the Benjamini and Hochberg multiple testing correction procedure. Quantitative real-time PCR (Q-RT-PCR) was used to verify select gene expression differences. The results show that CYB5 was significantly overexpressed in the high CYB5 sample by 1.8 fold (P < 0.05), verifying the known expression difference. The average log2 ratio of the majority of genes (1643) falls within one standard deviation of the mean, indicating the data were reproducible. In the high versus low steroidogenesis experiment, seven genes were significantly overexpressed in the high group (P < 0.05). Quantitative real-time PCR was used to validate five genes with the highest fold change, and the results corroborated those found by the microarray experiments. The results of the self-self hybridizations showed that no genes were significantly differentially expressed following the application of the Benjamini and Hochberg multiple testing correction procedure. The results presented in this report show that human arrays can be used for gene expression analysis in pigs.  相似文献   

11.
Human-associated microbiota is recognized to play vital roles in maintaining host health, and it is implicated in many disease states. While the initial surge in the profiling of these microbial communities was achieved with Sanger and next-generation sequencing, many oligonucleotide microarrays have also been developed recently for this purpose. Containing probes complementary to small ribosomal subunit RNA gene sequences of community members, such phylogenetic arrays provide direct quantitative comparisons of microbiota composition among samples and between sample groups. Some of the developed microarrays including PhyloChip, Microbiota Array, and HITChip can simultaneously measure the presence and abundance of hundreds and thousands of phylotypes in a single sample. This review describes the currently available phylogenetic microarrays that can be used to analyze human microbiota, delineates the approaches for the optimization of microarray use, and provides examples of recent findings based on microarray interrogation of human-associated microbial communities.  相似文献   

12.
13.

Background

The probe percent bound value, calculated using multi-state equilibrium models of solution hybridization, is shown to be useful in understanding the hybridization behavior of microarray probes having 50 nucleotides, with and without mismatches. These longer oligonucleotides are in widespread use on microarrays, but there are few controlled studies of their interactions with mismatched targets compared to 25-mer based platforms.

Principal Findings

50-mer oligonucleotides with centrally placed single, double and triple mismatches were spotted on an array. Over a range of target concentrations it was possible to discriminate binding to perfect matches and mismatches, and the type of mismatch could be predicted accurately in the concentration midrange (100 pM to 200 pM) using solution hybridization modeling methods. These results have implications for microarray design, optimization and analysis methods.

Conclusions

Our results highlight the importance of incorporating biophysical factors in both the design and the analysis of microarrays. Use of the probe “percent bound” value predicted by equilibrium models of hybridization is confirmed to be important for predicting and interpreting the behavior of long oligonucleotide arrays, as has been shown for short oligonucleotide arrays.  相似文献   

14.
15.
Microarrays have been used extensively in gene expression profiling and genotyping studies. To reduce the high cost and enhance the consistency of microarray experiments, it is often desirable to strip and reuse microarray slides. Our genome-wide analysis of microRNA expression involves the hybridization of fluorescently labeled nucleic acids to custom-made, spotted DNA microarrays based on GAPSII-coated slides. We describe here a simple and effective method to regenerate such custom microarrays that uses a very low-salt buffer to remove labeled nucleic acids from microarrays. Slides can be stripped and reused multiple times without significantly compromising data quality. Moreover, our analyses of the performance of regenerated slides identifies parameters that influence the attachment of oligonucleotide probes to GAPSII slides, shedding light on the interactions between DNA and the microarray surface and suggesting ways in which to improve the design of oligonucleotide probes.  相似文献   

16.
17.
We have conducted a study to compare the variability in measured gene expression levels associated with three types of microarray platforms. Total RNA samples were obtained from liver tissue of four male mice, two each from inbred strains A/J and C57BL/6J. The same four samples were assayed on Affymetrix Mouse Genome Expression Set 430 GeneChips (MOE430A and MOE430B), spotted cDNA microarrays, and spotted oligonucleotide microarrays using eight arrays of each type. Variances associated with measurement error were observed to be comparable across all microarray platforms. The MOE430A GeneChips and cDNA arrays had higher precision across technical replicates than the MOE430B GeneChips and oligonucleotide arrays. The Affymetrix platform showed the greatest range in the magnitude of expression levels followed by the oligonucleotide arrays. We observed good concordance in both estimated expression level and statistical significance of common genes between the Affymetrix MOE430A GeneChip and the oligonucleotide arrays. Despite their apparently high precision, cDNA arrays showed poor concordance with other platforms.  相似文献   

18.
We present a new protocol for the preparation of nucleic acids for microarray hybridization. DNA is fragmented quantitatively and reproducibly by using a hydroxyl radical-based reaction, which is initiated by hydrogen peroxide, iron(II)-EDTA and ascorbic acid. Following fragmentation, the nucleic acid fragments are densely biotinylated using a biotinylated psoralen analog plus UVA light and hybridized on microarrays. This non-enzymatic protocol circumvents several practical difficulties associated with DNA preparation for microarrays: the lack of reproducible fragmentation patterns associated with enzymatic methods; the large amount of labeled nucleic acids required by some array designs, which is often combined with a limited amount of starting material; and the high cost associated with currently used biotinylation methods. The method is applicable to any form of nucleic acid, but is particularly useful when applying double-stranded DNA on oligonucleotide arrays. Validation of this protocol is demonstrated by hybridizing PCR products with oligonucleotide-coated microspheres and PCR amplified cDNA with Affymetrix Cancer GeneChip microarrays.  相似文献   

19.
20.
微阵列(microarrays)技术及其应用   总被引:5,自引:0,他引:5  
微阵列分为cDNA微阵列和寡聚核苷酸微阵列,微阵列上“印”有大量已知部分序列的DNA探针,微阵列技术就是利用分子杂交原理,使同时被比较的标本(用同位素或荧光素标记)与微阵列杂交,通过检测杂交信号强度及数据处理,把他们转化成不同标本中特异基因的丰度,从而全国比较不同标本的基因表达水平的差异,微阵列技术是一种探索基因组功能的有力手段。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号