首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
A reliable high-performance liquid chromatographic method has been validated for determination of gallamine in rat plasma, muscle tissue and microdialysate samples. A C18 reversed-phase column with mobile phase of methanol and water containing 12.5 mM tetrabutyl ammonium (TBA) hydrogen sulphate (22:78, v/v) was used. The flow-rate was 1 ml/min with UV detection at 229 nm. Sample preparation involved protein precipitation with acetonitrile for plasma and muscle tissue homogenate samples. Microdialysate samples were injected into the HPLC system without any sample preparation. Intra-day and inter-day accuracy and precision of the assay were <13%. The limit of quantification was 1 μg/ml for plasma, 1.6 μg/g for muscle tissue and 0.5 μg/ml for microdialysate samples. The assay was applied successfully to analysis of samples obtained from a pharmacokinetic study in rats using the microdialysis technique.  相似文献   

2.
Aplidine (dehydrodidemnin B) is a new marine-derived depsipeptide with a powerful cytotoxic activity, which is under early clinical investigation in Europe and in the US. In order to investigate the pharmacokinetic properties of this novel drug, an HPLC–tandem mass spectrometry method was developed for the determination of aplidine in biological samples. Didemnin B, a hydroxy analogue, was used as internal standard. After protein precipitation with acetonitrile and extraction with chloroform, aplidine was chromatographed with a RP octadecylsilica column using a water–acetonitrile linear gradient in the presence of formic acid at the flow-rate of 500 μl/min. The method was linear over a 5–100 ng/ml range (LOD=0.5 ng/ml) in plasma and over a 1.25–125 ng/ml range (LOD=0.2 ng/ml) in urine with precision and accuracy below 14.0%. The intra- and inter-day precision and accuracy were below 12.5%. The extraction procedure recoveries for aplidine and didemnin B were 69% and 68%, respectively in plasma and 91% and 87%, respectively in urine. Differences in linearity, LOQ, LOD and recoveries between plasma and urine samples seem to be matrix-dependent. The applicability of the method was tested by measuring aplidine in rat plasma and urine after intravenous treatment.  相似文献   

3.
A novel analytical procedure was developed for the determination of the fluoroquinolone ofloxacin in chicken kidney, liver, muscle and fat plus skin tissues. The procedure involved a preliminary extraction with 0.15 M HCl followed by solid-phase extraction clean-up. The purification step was performed using a polymeric sorbent coated cartridge. Ofloxacin was analyzed by reversed-phase HPLC using UV detection at 295 nm. The mobile phase used was water–acetonitrile–triethylamine (83:14:0.45, v/v, pH 2.30). The use of triethylamine and the acidic pH modulated the retention of ofloxacin and avoided chemical tailing. The amine modifier and acetonitrile content of the mobile phase were optimized to provide the best selectivity. A flow-rate of 1 ml/min was used and ofloxacin eluted at 5.1 min. HPLC analysis of the tissue samples was performed in 12 min. The procedure was validated according to the International Conference on Harmonisation guidelines across the concentration ranges (100 μg/kg–1.7 mg/kg for kidney and liver tissues and 50 μg/kg–1.0 mg/kg for muscle and fat plus skin tissues). The linearity, the intra- and inter-day accuracies and precisions were determined. The limits of quantification were 50 μg/kg for muscle and fat plus skin tissues and 100 μg/kg for liver and kidney tissues. The procedure was specific and the accuracy values were lower than 20% at the limit of quantitation of spiked samples. The recovery values ranged from 80 to 100%. The limits of detection were established at 60 μg/kg for liver and kidney tissues and at 25 μg/kg for muscle and fat plus skin tissues. Finally, ofloxacin was found to be stable in acidic conditions. The developed procedure is simple, sensitive, accurate and adapted to routine sample analyses such as those carried out for residue depletion studies.  相似文献   

4.
An HPLC method was developed for the determination of formaldehyde in human blood plasma. The method was based on the determination of the fluorescent product of the chemical reaction between formaldehyde and ampicillin. A 0.2-ml aliquot of blood plasma was reacted directly with ampicillin under acidic and heating conditions. The reaction product was extracted from the matrix with diethyl ether and analyzed by reversed-phase HPLC with fluorescence detection. Recoveries of spiked formaldehyde at the low ppm (μg/ml) level were between 93% and 102% with relative standard deviations less than 8%. The limits of detection and quantitation of formaldehyde in blood plasma samples were 0.46 μg/ml and 0.87 μg/ml, respectively.  相似文献   

5.
The well-known beneficial health effects of Se have demanded the development of rapid and accurate methods for its analysis. A flow injection (FI) method with inductively coupled plasma mass spectrometry (ICP-MS) as a selenium-selective detector was optimized. Flow injection was carried out using a Knauer 1100 smartline inert series liquid chromatograph coupled with a Perkin Elmer DRC II ICP-mass spectrometer. For sample injection a Perkin Elmer electronic valve equipped with a 25 μL sample loop was employed. Before measurement, standards or samples were administered with 1 μg/L rhodium as internal standard for correction of changes in detector response according to changes in sample electrolyte concentration. The method characterization parameters are: LOD (3σ criterion): 26 ng/L, LOQ (10σ criterion): 86 ng/L, linearity: 0.05–>10 μg/L, r2=0.9999, serial or day-to-day precision at 2 μg/L: 4.48% or 5.6%. Accuracy was determined by (a) recovery experiments (CSF spiked with 2 μg/L Se); (b) comparison of FI-ICP-MS measurement with graphite furnace atomic absorption (GFAAS) measurements of 1:10 diluted serum samples; (c) Se determination in urine and serum control materials. Recovery (a) was 101.4%, measurement comparison with GFAAS (b) showed 98.8% (5 serum samples, 1:10 diluted in the range of 0.5–1.3 μg/L, compared to GFAAS determination, which was set to 100%), and accuracy was 96.8% or 105.6% for the serum or urine control material. Analysis time per sample was short and typically below 2 min for the complete measurement, including sample introduction, sample-line purge and quadruplicate Se determination.This method was used to determine Se in cerebrospinal fluid (CSF) and plasma (here parallel to GFAAS) in 35 paired serum and CSF samples. Se determination gave values in the range of 42–130 μg/L for serum and 1.63–6.66 μg/L for CSF. The median for Se in 35 individual CSF samples was 3.28 μg/L, the mean (±SD) was 3.67 (1.35) μg/L, whilst for individual serum samples the median was 81 μg/L and the mean (±SD) was 85 (26) μg/L. When relating the paired Se concentrations of CSF samples to respective serum samples it turned out that Se-CSF (behind blood brain barrier (BBB)) is independent on Se-serum concentration (before BBB).  相似文献   

6.
A rapid and accurate method for the determination of tetracycline in human plasma and urine is presented. Determination of tetracycline in plasma is based on precipitation of plasma proteins with trifluoroacetic acid, followed by injection of the centrifuged plasma sample onto a μBondapak C18 column. Acetonitrile in phosphate buffer pH 2.2 is used as mobile phase. Only tetracycline, and no trace of lumecycline can be detected in plasma and urine after administration of lumecycline, indicating that lumecycline is completely degraded to tetracycline, lysine and formaldehyde in the gastrointestinal tract prior to absorption.Determination of tetracycline in urine was performed by injection of urine diluted with phosphoric acid onto a μBondapak Phenyl column. The precision of determination of tetracycline in plasma, expressed as the relative standard deviation, was < 3% at tetracycline concentrations of 0.05 and 3.7 μg/ml. Urine determinations were made with a precision of < 1.5% at tetracycline concentrations of 0.5 and 6.7 μg/ml.  相似文献   

7.
A simple and rapid method is described for the GC–MS determination of 4-nonylphenols (NOs) and 4-tert-octylphenol (OC) in biological samples. The NOs and OC in the sample are extracted with acetonitrile and the lipid in the sample extract is eliminated by partitioning between hexane and acetonitrile. After Florisil PR column clean-up, the sample extract is analyzed by GC–MS in the selected ion monitoring (SIM) mode. Average recoveries in pale chub (fish) and corbicula (shellfish) are 86.0 and 93.4% for NOs, and 95.8 and 96.4% for OC, respectively, spiked at the levels of 1.0 μg of NOs and 0.1 μg of OC per 5 g of fish and shellfish samples. The detection limits are 20 ng/g for NOs and 2 ng/g for OC.  相似文献   

8.
Indomethacin and mefenamic acid are widely used clinically as non-steroidal anti-inflammatory agents. Both drugs have also been found effective to produce closure of patent ductus arteriosus in premature neonates. A simple, rapid, sensitive and reliable HPLC method is described for the determination of indomethacin and mefenamic acid in human plasma. As these drugs are not applied together, the compounds are alternately used as analyte and internal standard. Plasma was deproteinized with acetonitrile, the supernatant fraction was evaporated to dryness and the resulting residue was reconstituted in the mobile phase and injected into the HPLC system. The chromatographic separation was performed on a C18 column (250 × 4.6 mm I.D.) using 10 mM phosphoric acid—acetonitrile (40:60, v/v) as the mobile phase and both drugs were detected at 280 nm. The calibration graphs were linear with a correlation coefficient (r) of 0.999 or better from 0.1 to 10 μg/ml and the detection limits were 0.06 μg/ml for indomethacin and 0.08 μg/ml for mefenamic acid, for 50μl plasma samples. The method was not interfered with by other plasma components and has been found particularly useful for paediatric use. The within-day precision and accuracy of the method were evaluated for three concentrations in spiked plasma samples. The coefficients of variation were less than 5% and the accuracy was nearly 100% for both drugs.  相似文献   

9.
A sensitive and selective high-performance liquid chromatographic method has been developed for a new anticonvulsant, fluzinamide, and three of its active metabolites. This method requires only 0.5 ml of plasma, and it involves a single extraction with a mixture of hexane—dichloromethane—butanol (55:40:5). The plasma extract is chromatographed on a 10-μm, C18 reversed-phase column and quantitated by ultraviolet absorbance at 220 nm. The concentration—response curve for all four compounds are linear from 0.05 μg/ml to at least 10 μg/ml. The extraction efficiency of this method is greater than 90%. The accuracy and precision of the method were tested by analyzing spiked unknown samples that had been randomly distributed across the concentration range. The mean concentrations found were within ± 9% of the various amounts added with a standard deviation of ± 3.5%. This method has been successfully applied to the analysis of samples obtained from fluzinamide-dosed dogs, healthy unmedicated volunteers, and patients who were at steady state with phenytoin, carbamazepine, and fluzinamide.  相似文献   

10.
This study describes a HPLC method to determine the concentrations of acetylsalicylic acid (ASA) and salicylic acid (SA) in human stratum corneum and in plasma. The stratum corneum layers for ASA/SA analysis were removed from three patients with postherpetic hyperalgesia treated with topical and oral aspirin. Blood samples were also collected from the same patients. Tape strippings were placed in acetonitrile and sonicated for 15 min. After centrifuging, aliquots of the supernatant were injected into the chromatograph. ASA and SA from plasma samples were extracted on Isolute C8 columns. Due to interfering peaks in the tape samples, HPLC conditions were slightly different for tape and plasma samples. ASA and SA were separated on a LiChrospher 100 RP-18 column at 1 ml/min using a water–phosphate buffer (pH 2.5)–acetonitrile mobile phase (35:40:25, v/v/v). A linear response to quantities of ASA from 0.1 to 100 μg/cm2 and of SA from 0.1 to 5 μg/cm2 in tape and to quantities of ASA 0.1 to 2 μg/ml and 1 to 50 μg/ml was obtained and the recovery from tape and plasma samples was over 98%. The method is sensitive (0.1 μg/cm2) and specific enough to allow the determination of the drugs in the skin not only after topical but also after oral administration. A good sensitivity was also obtained in plasma (0.1 μg/ml) allowing study of the kinetics of ASA and SA in plasma after oral administration. Concentrations of ASA after topical administration were 100–200 times higher than after oral administration. Plasma levels of ASA and SA after oral administration were similar to those previously found. No ASA or SA were detected in plasma after topical ASA administration.  相似文献   

11.
Achiral and chiral HPLC methods were developed for clinafloxacin, a quinolone antimicrobial agent. For achiral assay, analytes were isolated from plasma by precipitating plasma proteins. Separation was achieved on a C18 column using an isocratic eluent of ion pairing solution–acetonitrile (80:20, v/v) at 1.0 ml/min with UV detection at 340 nm. The ion pairing solution was 0.05 M citric acid, 1.15 mM tetrabutylammonium hydroxide and 0.1% ammonium perchlorate. Inter-assay accuracy was within 4.9% with an inter-assay precision of 3.7% over a quantitation range of 0.025 to 10.0 μg/ml. For chiral assay, analytes were isolated from plasma by solid-phase extraction. Separation was achieved on a Crownpak CR(+) column using an isocratic eluent of water–methanol (88:12, v/v) containing 0.1 mM decylamine at 1.0 ml/min with UV detection at 340 nm. Perchloric acid was added to adjust pH to 2. Inter-assay accuracy was within 3.5% with a inter-assay precision of 5.4% over a quantitation range of 0.040 to 2.5 μg/ml.  相似文献   

12.
We have established an ultra-sensitive method for determination of ethanol in whole blood by headspace capillary gas chromatography (GC) with cryogenic oven trapping. After heating a blood sample containing ethanol and isobutyl alcohol (internal standard, IS) in a 7.0-ml vial at 55°C for 15 min, 5 ml of the headspace vapor was drawn into a glass syringe and injected into a GC port. All vapor was introduced into an Rtx-BAC2 wide-bore capillary column in the splitless mode at −60°C oven temperature to trap entire analytes, and then the oven temperature was programmed up to 240°C for GC measurements with flame ionization detection. The present method gave sharp peaks of ethanol and IS, and low background noise for whole blood samples. The mean partition into the gaseous phase for ethanol and IS was 3.06±0.733 and 8.33±2.19%, respectively. The calibration curves showed linearity in the range 0.02–5.0 μg/ml whole blood. The detection limit was estimated to be 0.01 μg/ml. The coefficients of intra-day and inter-day variation for spiked ethanol were 8.72 and 9.47%, respectively. Because of the extremely high sensitivity, we could measure low levels of endogenous ethanol in whole blood of subjects without drinking. The concentration of endogenous ethanol measured for 10 subjects under uncontrolled conditions varied from 0 to 0.377 μg/ml (mean, 0.180 μg/ml). Data on the diurnal changes of endogenous ethanol in whole blood of five subjects under strict food control are also presented; they are in accordance with the idea that endogenous blood ethanol is of enteric bacterial origin.  相似文献   

13.
A rapid, selective and accurate high-performance liquid chromatography–tandem mass spectrometry assay for the quantification of sanfetrinem in human plasma has been developed and validated. The performance of manual and automated sample preparation was assessed; 50 μl of plasma sample was deproteinized with acetonitrile, followed by dilution with water and injection onto the LC system. Chromatographic separation was achieved on a Phenomenex Luna C18(2), 50×2.0 (5 μm) column with a mobile phase consisting of water–acetonitrile with 0.1% formic acid followed by detection with a Perkin-Elmer API3000 mass spectrometer in multiple reaction monitoring mode. The lower limit of quantification was improved by five times compared to the UV method previously reported. A range of concentration from 10 ng/ml to 5 μg/ml was covered. The method was applied to the quantification of sanfetrinem in human plasma samples from healthy volunteers participating in a clinical study.  相似文献   

14.
A high-performance liquid chromatographic (HPLC) assay has been developed for the determination of the antifungal drug fluconazole in saliva and plasma of patients infected with the human immunodeficiency virus (HIV). Samples can be heated at 60°C for 30 min to inactivate the virus without loss of the analyte. The sample pretreatment involves a liquid-liquid extraction with chloroform-1-propanol (4:1, v/v). The chromatographic analysis is performed on a Lichrosorb RP-18 (5 μm) column by isocratic elution with a mobile phase of 0.01 M acetate buffer (pH 5.0)-methanol (70:30, v/v) and ultraviolet (UV) detection at 261 nm. The lower limit of is 100 ng/ml in plasma (using 500-μl samples) and 1 μg/ml in saliva (using 250-μl samples) and the method is linear up to 100 μg/ml in plasma and saliva. At a concentration of 5 μg/ml the within-day and between-day precision in plasma are 7.1 and 5.7%, respectively. In saliva the within-day and between-day precision is 10.8% (at 5 μg/ml). The methodology is now being used in pharmacokinetic studies in HIV-infected patients in our hospital.  相似文献   

15.
A HPLC method with automated column switching and UV detection is described for the simultaneous determination of retinol and major retinyl esters (retinyl palmitate, retinyl stearate, retinyl oleate and retinyl linoleate) in human plasma. Plasma (0.2 ml) was deproteinized by adding ethanol (1.5 ml) containing the internal standard retinyl propionate. Following centrifugation the supernatant was directly injected onto the pre-column packed with LiChrospher 100 RP-18 using 1.2% ammonium acetate–acetic acid–ethanol (80:1:20, v/v) as mobile phase. The elution strength of the ethanol containing sample solution was reduced by on-line supply of 1% ammonium acetate–acetic acid–ethanol (100:2:4, v/v). The retained retinol and retinyl esters were then transferred to the analytical column (Superspher 100 RP-18, endcapped) in the backflush mode and chromatographed under isocratic conditions using acetonitrile–methanol–ethanol–2-propanol (1:1:1:1, v/v) as mobile phase. Compounds of interest were detected at 325 nm. The method was linear in the range 2.5–2000 ng/ml with a limit of quantification for retinol and retinyl esters of 2.5 ng/ml. Mean recoveries from plasma were 93.4–96.5% for retinol (range 100–1000 ng/ml) and 92.7–96.0% for retinyl palmitate (range 5–1000 ng/ml). Inter-assay precision was ≤5.1% and ≤6.3% for retinol and retinyl palmitate, respectively. The method was successfully applied to more than 2000 human plasma samples from clinical studies. Endogenous levels of retinol and retinyl esters determined in female volunteers were in good accordance with published data.  相似文献   

16.
This paper describes a high-performance liquid chromatographic method for the assay of quinfamide and its main metabolite, 1-(dichloroacetyl)-1,2,3,4,-tetrahydro-6-quinolinol, in plasma, urine and feces. It requires 1 ml of biological fluid, an extraction using Sep-Pack cartridges and acetonitrile for drug elution. Analysis was performed on a CN column (5 μm) using water–acetonitrile–methanol (40:50:10) as a mobile phase at 269 nm. Results showed that the assay was linear in the range between 0.08 and 2.0 μg/ml. The limit of quantitation was 0.08 μg/ml. Maximum assay coefficient of variation was 14%. Recovery obtained in plasma, urine and feces ranged from 82% to 98%.  相似文献   

17.
The determination of residues of benzimidazole using liquid chromatography and tandem mass spectrometry (LC–MS–MS) with ion spray ionization is described. Swine muscle tissue was spiked with a mixture of fifteen benzimidazoles, including metabolites of fenbendazole and albendazole. As clean-up procedure, an ethyl acetate extraction followed by solid-phase extraction on styrol-divinyl-benzene cartridge was used. The evaluation was performed by selecting the characteristic product ions for the benzimidazoles and using multiple reaction mode. 2-n-Butylmercaptobenzimidazole was used as internal standard. Blank muscle samples were fortified in the concentration range of 1–22 μg/kg. The limits of detection were below 6 μg/kg and the limits of quantification for most benzimidazoles were below 10 μg/kg. The matrix effect was checked using spiked muscle tissues of cattle and sheep as well as liver of cattle. Practical application will be shown by incurred egg material from laying hens treated with flubendazole. The recovery of the clean-up was mostly above 50% in muscle tissue and 70% in egg yolk.  相似文献   

18.
A stable-isotope based gas chromatography–tandem mass spectrometry–negative ion chemical ionization method was developed for the determination of norepinephrine (NE) levels in small volumes (25–100 μl) of plasma. NE was stabilized in plasma by the addition of semicarbazide and spiked with deuterium-labeled norepinephrine internal standard. The analytes were isolated from the plasma by solid-phase extraction using phenylboronic acid columns and derivatized using pentafluoropropionic anhydride. The derivatized analytes were chromatographed on a capillary column and detected by tandem mass spectrometry with negative ion chemical ionization. Unparalleled sensitivity and selectivity were obtained using this detection scheme, allowing the unambiguous analysis of trace levels of NE in small-volume plasma samples. Linear standard curves were obtained for NE over a mass range from 1 to 200 pg per sample. The method had a limit of quantitation of 10 pg NE/ml plasma when using a 100-μl sample aliquot (1 pg/sample). Accuracy for the analysis of plasma samples spiked with 10 to 200 pg NE/ml typically ranged from 100±10%, with RSD values of less than 10%. The methodology was applied to determine the effect of clonidine on plasma NE levels in conscious spontaneously hypertensive rats. Administration of clonidine (30 μg/kg) produced an 80% reduction in plasma NE accompanied by a 30% reduction in heart and mean arterial pressure that persisted >90 min after drug administration. The ability to take multiple samples from individual rats allowed the time course for the effect of clonidine to be mapped out using only one group of animals.  相似文献   

19.
A rapid and simple method for determination of the novel antiepileptic compound gabapentin [1-(aminomethyl)cyclohexaneacetic acid] in plasma is described. Blank human plasma was spiked with gabapentin (1.0–10.0 μg/ml) and internal standard [1-(aminomethyl)-cycloheptaneacetic acid; 5.0 μg/ml]. Individual samples were treated with 2 M perchloric acid, centrifuged and then derivatised with o-phthalaldehyde-3-mercaptopropionic acid. Separation was achieved on a Beckman Ultrasphere 5 μm reversed-phase column with mobile phase consisting of 0.33 M acetate buffer (pH 3.7; containing 100 mg/l EDTA)-methanol-acetonitrile (40:30:30, v/v). Eluents were monitored by fluorescence spectroscopy with excitation and emission wavelengths of 330 and 440 nm, respectively. The calibration curve for gabapentin in plasma was linear (r=0.9997) over the concentration range 1.0–10.0 μg/ml. Recovery was seen to be 90%. The inter- and intra-assay variations for three different gabapentin concentrations were 10% throughout. The lower limit of quantitation was found to be 0.5 μg/ml. Chromatography was unaffacted by a range of commonly employed antiepileptic drugs or selected amino acids.  相似文献   

20.
A rapid high-performance liquid chromatographic method was developed using a short silica column (30 mm×4.6 mm) with an aqueous methanol mobile phase consisting of methanol–water–NH4H2PO4 (94:5.96:0.04) adjusted to a final apparent pH of 5.0 and pumped at a flow-rate of 1 ml/min. Ultraviolet detection was carried out at a wavelength of 280 nm, and serum samples were prepared for HPLC analysis by extraction into dichloromethane after basification. Lamotrigine was eluted at 0.96 min. Within-day variation of the method was 4.46% at 0.75 μg/ml and 2.37% at 6.0 μg/ml, and day-to-day variation was 9.10% at 0.75 μg/ml and 7.28% at 6.0 μg/ml.  相似文献   