首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
3.
4.
5.
In six sheep, radiopaque markers were placed on the left ventricle (LV), the mitral annulus, the left atrium (LA), and the central edge of both mitral leaflets to investigate the effects of acute LV ischemia on atrial contraction, mitral annular area (MAA), and mitral regurgitation (MR). Animals were studied with biplane videofluoroscopy and transesophageal echocardiography before and during balloon occlusion of the left anterior descending (LAD), distal circumflex (dLCX), and proximal circumflex (pLCX) coronary arteries. MAA and LA area were calculated from the corresponding markers. LAD occlusion did not alter LA area reduction or presystolic MAA reduction, whereas dLCX occlusion resulted in a mild decrease in the former with no change in the latter. Neither occlusion resulted in MR. pLCX occlusion, however, significantly decreased LA area and presystolic MAA reduction and resulted in increased end-diastolic MAA, delayed valve closure from end diastole, and MR. Decreased atrial contractile function, as observed during acute posterolateral ischemia, is linked to diminished presystolic mitral annular reduction, a larger mitral annular size at end diastole, and MR.  相似文献   

6.
目的应用微电极阵列芯片(microelectrode arrays chip,MEA)技术评价48 h房颤(atrial fibrillation,AF)犬左、右心耳(LAA、RAA)的电生理特性。方法随意来源犬12只,以600次/分起搏右心房建立AF模型,分为48 h AF组(n=6)和对照组(n=6)。造模成功后迅速开胸剪取LAA、RAA,置于盛有台式液的MEA中,分别记录AF组及对照组LAA、RAA场电位(field action potential,FAP)形态、振幅、放电频率及激动传导情况。结果 AF组LAA、RAA组织FAP节律绝对不齐,LAA(185.22±25.62)次/分,较对照组(156.44±8.88)次/分增加15.67%(P〈0.01),RAA(102.39±16)次/分,较对照组(156.44±8.88)次/分减慢34.62%(P〈0.01)。48 h AF组LAA组织电压(458.33±26.73)μV较对照组(740.55±18.93)μV降低38.11%(P〈0.01),RAA(504.83±39.93)μV较对照组(840.56±18.93)μV明显降低(P〈0.01),48 h房颤组LAA组织FAP时程(45.28±8.59)ms较对照组(70.77±6.98)ms缩短15 ms(P〈0.01)。RAA(61.78±7.1)ms较对照组(75.83±7.63)ms缩短14 ms(P〈0.01)。48 h AF组LAA、RAA FAP传导异质性增加。结论应用MEA技术可反映心肌组织片场电位电生理特性,48 h AF后LAA放电频率增加,频率绝对不齐,LAA、RAA电压降低,场电位时程延长。  相似文献   

7.
Atrial conduction properties have been shown to differ among animal atrial fibrillation (AF) models of rapid atrial pacing (RAP), chronic mitral regurgitation (MR), and control. We hypothesized that these conduction differences would continue with the onset of AF, which would affect AF spatiotemporal organization, resulting in model-specific characteristics of AF. With frequency domain analysis of electrograms acquired from high-density optical mapping, AF from the right (RA) and left (LA) atrium in animals with RAP and MR were compared with control animals. At follow-up, the hearts were excised and perfused, and optical action potentials were recorded from a 2 x 2-cm area each of the RA and LA free wall with a 16 x 16 photodiode array. AF was induced with extra stimuli, several 2.4-s AF episodes were recorded in each dog, and a fast Fourier transform was calculated. The dominant frequency (DF) was determined, and the organization (organization index, OI) was calculated as the ratio of the area under the dominant peak and its harmonics to the total area of the spectrum. All possible pairs of electrograms for each episode were cross-correlated. LA AF in the chronic MR model showed an increase in the highest DF, the number of DF domains, and in frequency gradient compared with AF in control or RAP models. In addition, there was a decrease in OI and in the correlation coefficients in the LA of the MR model. These results suggest that the AF substrate in the MR model may be different from that of control or RAP models.  相似文献   

8.
9.
10.
BackgroundOesophageal changes and injuries were recorded after atrial fibrillation(AF) ablation procedures. The reduction of power in the posterior left atrial(LA) wall(closest to the oesophagus) and the monitoring of temperature in the oesophagus(OE) reduced oesophageal injuries. The intracardiac-echocardiography(ICE) with a Cartosound module provides two-dimensional imaging (2D) to assess detailed cardiac anatomy and its relationship with the OE. The aim of this study was to highlight the safety and feasibility of 3D-reconstruction of the oesophageal course in left atrial catheter ablation(CA) procedures without OE temperature probe or quadripolar catheter to guide ICE OE reconstruction.Methods180 patients(PT) underwent left atrial ablation. AF ablation were 125(69.5%); incisional left atrial tachycardias(IAFL) were 37(20.6%); left atrial tachycardias(LAT) were 19(10.6%). The LA and pulmonary vein anatomies were rendered by traditional electroanatomic mapping(EAM) and merged with an ICE anatomic map. In 109 PT ICE imaging was used to create a geometry of the OE(group A). A quadripolar catheter was used in 71 PT to show OE course associated to ICE(group B).ResultsAblation energy delivery was performed outside the broadest OE anatomy borders. The duration of procedures was longer in group B vs group A Fluoroscopy time was lower in Group A than Group B(Group A 7 ± 3.2 vs 19.2 ± 2.4 min; p < 0.01).ConclusionsOE monitoring with ICE is safe and feasible. Oesophageal anatomy is complex and variable. Many PT will have a broad oesophageal boundary, which increases the risk of untoward thermal injury during posterior LA ablation. ICE with 3D construction of the OE enhances border detection of the OE, and as such, should decrease the risk of oesophageal injury by improving avoidance strategies without intra-oesophageal catheter visualization.  相似文献   

11.
12.
13.

Background

Atrial fibrillation (AF) can result in atrial functional mitral regurgitation (MR), but the mechanism remains controversial. Few data about the relationship between the 3-dimensional morphology of the MV and the degree of MR in AF exist.

Methods

Real-time 3-dimensional transesophageal echocardiography (3D-TEE) of the MV was acquired in 168 patients with AF (57.7% persistent AF), including 25 (14.9%) patients with moderate to severe MR (the MR+ group) and 25 patients without AF as controls. The 3-dimensional geometry of the MV apparatus was acquired using dedicated quantification software.

Results

Compared with the group of patients with no or mild MR (the MR- group) and the controls, the MR+ group had a larger left atrium (LA), a more dilated mitral annulus (MA), a reduced annular height to commissural width ratio (AHCWR), indicating flattening of the annular saddle shape, and greater leaflet surfaces and tethering. MR severity was correlated with the MA area (r2?=?0.43, P?<?0.01) and the annulus circumference (r2?=?0.38, P?<?0.01). A logistic regression analysis indicated that the MA area (OR: 1.02, 95% CI: 1.01–1.03, P?<?0.01), AHCWR (OR: 0.24, 95% CI: 0.14–0.35, P?=?0.04) and MV tenting volume (OR: 3.24, 95% CI: 1.16–9.08, P?=?0.03) were independent predictors of MR severity in AF patients.

Conclusions

The mechanisms of “atrial functional MR” are complex and include dilation of the MA, flattening of the annular saddle shape and greater leaflet tethering.
  相似文献   

14.
15.
16.
The variations in ventricular-atrial mitral annular position during the cardiac cycle and the simultaneous changes in left atrial silhouette area (obtained by angiography after injections of contrast material into the main pulmonary artery) were investigated in six experiments on intact dogs with chronically implanted intracardiac markers. Frame-by-frame measurements of the angiograms (120 frames/s) were used to determine, under various hemodynamic conditions, the duration, magnitude, and average rate of the mitral annular motion and of the simultaneous changes in left atrial area during atrial filling (ventricular systole) and atrial emptying (early in ventricular diastole). The mitral annulus was seen to move towards the ventricular apex during systole and towards the atrium early in diastole with the duration, average rate, and magnitude of displacement (although varying widely) showing good statistical correlations (P less than 0.0005-0.005) with the changes in projected left atrial area. These findings suggest that the duration, rate, and magnitude of atrial filling and emptying may be, in the intact heart, determined by the movements of the atrioventricular junction.  相似文献   

17.
The flow inside a model left ventricle during filling (diastole) is simulated by the numerical solution of the equations of motion under the axisymmetric approximation. The left ventricle is taken with a truncated ellipsoid geometry, and a simple conceptual model is introduced to simulate the presence of the moving mitral valve. A relevant role during the left ventricle diastolic flow, as already discussed by other authors, is played by the travelling vortex wake that is formed from the transmitral jet during the early filling acceleration phase. The presence of a moving valve is found to produce a non-simultaneous spatial development of the entering bulk flow and a slightly more complex vortex wake structure; the results are discussed in comparison with fixed valve ones. They are analysed also in terms of M-mode representation suggesting a physical interpretation of the pattern detected in the clinical measurements that extends the one given previously on the basis of fixed valve models.  相似文献   

18.
Persistent left superior vena cava is a rarely seen anomaly but it may be an arrhythmogenic source for paroxysmal atrial fibrillation. Furthermore, the complex anatomicregion between the left superior vena cava and the pulmonary veins may leads to misinterpretation of the pulmonary vein recordings during atrial fibrillation ablation. Approaches that might be helpful to overcome these problems are discussed in this case report.  相似文献   

19.
20.
A variety of cellular lesions were manifested by the free-living larval stages of Nippostrongylus brasiliensis cultured axenically in medium lacking cholesterol. Pathologic changes developed rapidly and were most apparent in intestinal cells which displayed generalized degradation of membranous organelles. Mitochondria, endoplasmic reticulum, and Golgi complexes became disassociated and vacuolated. Autophagosomes appeared within intestinal cells and contained a wide variety of cellular components. By the 5th day gross vacuolization and degeneration of intestinal cells occurred and the hypodermis and lateral cords displayed lysed cytoplasmic regions. The latter structures are concerned with synthesis of cuticle and their degeneration correlates with the suppression of molting and the abnormal molts that occurred.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号