首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The aim of this study was to examine the effect of aging and training status on ventilatory response during incremental cycling exercise. Eight young (24 ± 5 years) and 8 older (64 ± 3 years) competitive cyclists together with 8 young (27 ± 4 years) and 8 older (63 ± 2 years) untrained individuals underwent a continuous incremental cycling test to exhaustion to determine ventilatory threshold (VT), respiratory compensation point (RCP), and maximal oxygen uptake (VO?max). In addition, the isocapnic buffering (IB) phase was calculated together with the hypocapnic hyperventilation. Ventilatory threshold occurred at similar relative exercise intensities in all groups, whereas RCP was recorded at higher intensities in young and older cyclists compared to the untrained subjects. The IB phase, reported as the difference between VT and RCP and expressed either in absolute (ml·min?1·kg?1 VO?) or in relative terms, was greater (p < 0.01) in both young and older trained cyclists than in untrained subjects, who were also characterized by a lower exercise capacity. Isocapnic buffering was particularly small in the older untrained volunteers. Although young untrained and older trained subjects had a similar level of VO?max, older athletes exhibited a larger IB. In addition, a higher absolute but similar relative IB was observed in young vs. older cyclists, despite a higher VO?max in the former. In conclusion, the present study shows that aging is associated with a reduction of the IB phase recorded during an incremental exercise test. Moreover, endurance training induces adaptations that result in an enlargement of the IB phase independent of age. This information can be used for the characterization and monitoring of the physiological adaptations induced by endurance training.  相似文献   

2.
This study compared the activation pattern and the fatigue rate among the superficial muscles of the quadriceps femoris (QF) during severe cycling exercise. Peak oxygen consumption (VO(2)peak) and maximal accumulated oxygen Deficit (MAOD) were established by 10 well-trained male cyclists (27.5 ± 4.1 years, 71.0 ± 10.3 kg, 173.4 ± 6.6 cm, mean VO(2)peak 56.7 ± 4.4 ml·kg·min(-1), mean MAOD 5.7 ± 1.1 L). Muscle activity (electromyographic [EMG] signals) was obtained during the supramaximal constant workload test (MAOD) and expressed by root mean square (RMS) and median frequency (MF slope). The RMS of the QF, vastus lateralis (VL) and vastus medialis (VM) muscles were significantly higher than at the beginning after 75% of exercise duration, whereas for the rectus femoris (RF), this was observed after 50% of exercise duration (p ≤ 0.05). The slope of the MF was significantly higher in the RF, followed by the VL and VM (-3.13 ± 0.52 vs. -2.61 ± 0.62 vs. -1.81 ±0.56, respectively; p < 0.05). We conclude that RF may play an important role in limiting performance during severe cycling exercise.  相似文献   

3.
The origin of the slow component (SC) of oxygen uptake kinetics, presenting during exercise above the ventilatory threshold (VT), remains unclear. Possible physiologic mechanisms include a progressive recruitment of type II muscle fibers. The purpose of this study was to examine alterations in muscle activity through electromyography (EMG) and mean power frequency (MPF) analysis during heavy cycling exercise. Eight trained cyclists (mean +/- S.E.; age = 30 +/- 3 years, height = 1771 +/- 4 cm, weight = 73.8 +/- 6.5 kg, VO2max = 4.33 +/- 0.28 l min(-1)) completed transitions from 20W to a workload equaling 50% of the difference between V(T) and VO2max. VO2 was monitored using a breath-by-breath measurement system, and EMG data were gathered from surface electrodes placed on the gastrocnemius lateralis and vastus lateralis oblique. Breath-by-breath data were time aligned, averaged, interpolated to 1-s intervals, and modeled with non-linear regression. Mean power frequency (MPF) and RMS EMG values were calculated for each minute during the exercise bout. Additionally, MPF was determined using both isolated EMG bursts and complete pedal revolutions. All subjects exhibited a VO2 SC (mean amplitude = 0.98 +/- 0.16 l min(-1)), yet no significant differences were observed during the exercise bout in MPF or RMS EMG data (p > 0.05) using either analysis technique. While it is possible that the sensitivity of EMG may be insufficient to identify changes in muscle activity theorized to affect the VO2 SC, the data indicated no relationship between MPF/EMG and the SC during heavy cycling.  相似文献   

4.
In this study, we have determined power output reached at maximal oxygen uptake during incremental cycling exercise (P(I, max)) performed at low and at high pedaling rates in nineteen untrained men with various myosin heavy chain composition (MyHC) in the vastus lateralis muscle. On separate days, subjects performed two incremental exercise tests until exhaustion at 60 rev min(-1) and at 120 rev min(-1). In the studied group of subjects P(I, max) reached during cycling at 60 rev min(-1) was significantly higher (p=0.0001) than that at 120 rev min(-1) (287+/-29 vs. 215+/-42 W, respectively for 60 and 120 rev min(-1)). For further comparisons, two groups of subjects (n=6, each) were selected according to MyHC composition in the vastus lateralis muscle: group H with higher MyHC II content (56.8+/-2.79 %) and group L with lower MyHC II content in this muscle (28.6+/-5.8 %). P(I, max) reached during cycling performed at 60 rev min(-1) in group H was significantly lower than in group L (p=0.03). However, during cycling at 120 rev min(-1), there was no significant difference in P(I, max) reached by both groups of subjects (p=0.38). Moreover, oxygen uptake (VO(2)), blood hydrogen ion [H(+)], plasma lactate [La(-)] and ammonia [NH(3)] concentrations determined at the four highest power outputs completed during the incremental cycling performed at 60 as well as 120 rev min(-1), in the group H were significantly higher than in group L. We have concluded that during an incremental exercise performed at low pedaling rates the subjects with lower content of MyHC II in the vastus lateralis muscle possess greater power generating capabilities than the subjects with higher content of MyHC II. Surprisingly, at high pedaling rate, power generating capabilities in the subjects with higher MyHC II content in the vastus lateralis muscle did not differ from those found in the subjects with lower content of MyHC II in this muscle, despite higher blood [H(+)], [La(-)] and [NH(3)] concentrations. This indicates that at high pedaling rates the subjects with higher percentage of MyHC II in the vastus lateralis muscle perform relatively better than the subjects with lower percentage of MyHC II in this muscle.  相似文献   

5.
The purpose of this study was to investigate the relationship between muscle oxygenation level at exhaustion and maximal oxygen uptake (VO2max) in an incremental cycling exercise. Nine male subjects took part in an incremental exhaustive cycling exercise, and then cuff occlusion was performed. Changes in oxy-(deltaHbO2) and deoxy-(deltaHb) hemoglobin concentrations in the vastus lateralis muscle were measured with a near infrared spectroscopy (NIRS). Muscle oxygenation during incremental exercise was expressed as a percentage (%Moxy) of the maximal range observed during an arterial occlusion as the lower reference point. A systematic decrease was observed in %Moxy with increasing intensity. A significant relationship was observed between %Moxy at exhaustion and VO2max (p < 0.01). We concluded that the one of the limiting factor of VO2max is the muscle oxygen diffusion capacity, and %Moxy during exercise could be one of the indexes of muscle oxygen diffusion capacity.  相似文献   

6.
The aim of this study was to examine the relationship between the content of various types of myosin heavy chain isoforms (MyHC) in the vastus lateralis muscle and pulmonary oxygen uptake during moderate power output incremental exercise, performed at low and at high pedalling rates. Twenty one male subjects (mean +/- SD) aged 24.1 +/- 2.8 years; body mass 72.9 +/- 7.2 kg; height 179.1 +/- 4.8 cm; BMI 22.69 +/- 1.89 kg.m(-2); VO2max 50.6 +/- 5.3 ml.kg.min(-1), participated in this study. On separate days, they performed two incremental exercise tests at 60 rev.min(-1) and at 120 rev.min(-1), until exhaustion. Gas exchange variables were measured continuously breath by breath. Blood samples were taken for measurements of plasma lactate concentration prior to the exercise test and at the end of each step of the incremental exercise. Muscle biopsies were taken from the vastus lateralis muscle, using Bergstr?m needle, and they were analysed for the content of MyHC I and MyHC II using SDS--PAGE and two groups (n=7, each) were selected: group H with the highest content of MyHC II (60.7 % +/- 10.5 %) and group L with the lowest content of MyHC II (27.6 % +/- 6.1 %). We have found that during incremental exercise at the power output between 30-120 W, performed at 60 rev.min(-1), oxygen uptake in the group H was significantly greater than in the group L (ANCOVA, p=0.003, upward shift of the intercept in VO2/power output relationship). During cycling at the same power output but at 120 rev.min(-1), the oxygen uptake was also higher in the group H, when compared to the group L (i.e. upward shift of the intercept in VO2/power output relationship, ANCOVA, p=0.002). Moreover, the increase in pedalling rate from 60 to 120 rev.min(-1) was accompanied by a significantly higher increase of oxygen cost of cycling and by a significantly higher plasma lactate concentration in subjects from group H. We concluded that the muscle mechanical efficiency, expressed by the VO2/PO ratio, during cycling in the range of power outputs 30-120 W, performed at 60 as well as 120 rev.min(-1), is significantly lower in the individuals with the highest content of MyHC II, when compared to the individuals with the lowest content of MyHC II in the vastus lateralis.  相似文献   

7.
Determinants of endurance in well-trained cyclists   总被引:7,自引:0,他引:7  
Fourteen competitive cyclists who possessed a similar maximum O2 consumption (VO2 max; range, 4.6-5.0 l/min) were compared regarding blood lactate responses, glycogen usage, and endurance during submaximal exercise. Seven subjects reached their blood lactate threshold (LT) during exercise of a relatively low intensity (group L) (i.e., 65.8 +/- 1.7% VO2 max), whereas exercise of a relatively high intensity was required to elicit LT in the other seven men (group H) (i.e., 81.5 +/- 1.8% VO2 max; P less than 0.001). Time to fatigue during exercise at 88% of VO2 max was more than twofold longer in group H compared with group L (60.8 +/- 3.1 vs. 29.1 +/- 5.0 min; P less than 0.001). Over 92% of the variance in performance was related to the % VO2 max at LT and muscle capillary density. The vastus lateralis muscle of group L was stressed more than that of group H during submaximal cycling (i.e., 79% VO2 max), as reflected by more than a twofold greater (P less than 0.001) rate of glycogen utilization and blood lactate concentration. The quality of the vastus lateralis in groups H and L was similar regarding mitochondrial enzyme activity, whereas group H possessed a greater percentage of type I muscle fibers (66.7 +/- 5.2 vs. 46.9 +/- 3.8; P less than 0.01). The differing metabolic responses to submaximal exercise observed between the two groups appeared to be specific to the leg extension phase of cycling, since the blood lactate responses of the two groups were comparable during uphill running. These data indicate that endurance can vary greatly among individuals with an equal VO2 max.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

8.
The aim of the study was to investigate the correlation between myosin heavy chain (MHC) composition, lactate threshold (LT), maximal oxygen uptake VO2max, and average muscle fiber conduction velocity (MFCV) measured from surface electromyographic (EMG) signals during cycling exercise. Ten healthy male subjects participated in the study. MHC isoforms were identified from a sample of the vastus lateralis muscle and characterized as type I, IIA, and IIX. At least three days after a measure of LT and VO2max, the subjects performed a 2-min cycling exercise at 90 revolutions per minute and power output corresponding to LT, during which surface EMG signals were recorded from the vastus lateralis muscle with an adhesive electrode array. MFCV and instantaneous mean power spectral frequency of the surface EMG were estimated at the maximal instantaneous knee angular speed. Output power corresponding to LT and VO2max were correlated with percentage of MHC I (R2=0.77; and 0.42, respectively; P<0.05). MFCV was positively correlated with percentage of MHC I, power corresponding to LT and to VO2max (R2=0.84; 0.74; 0.53, respectively; P<0.05). Instantaneous mean power spectral frequency was not correlated with any of these variables or with MFCV, thus questioning the use of surface EMG spectral analysis for indirect estimation of MFCV in dynamic contractions.  相似文献   

9.
O2 uptake (VO2) kinetics and electromyographic (EMG) activity from the vastus medialis, rectus femoris, biceps femoris, and medial gastrocnemius muscles were studied during constant-load concentric and eccentric cycling. Six healthy men performed transitions from baseline to high-intensity eccentric (HE) exercise and to high-intensity (HC), moderate-intensity (MC), and low-intensity (LC) concentric exercise. For HE and HC exercise, absolute work rate was equivalent. For HE and LC exercise, VO2 was equivalent. VO2 data were fit by a two- or three-component exponential model. Surface EMG was recorded during the last 12 s of each minute of exercise to obtain integrated EMG and mean power frequency. Only in the HC exercise did VO2 increase progressively with evidence of a slow component (phase 3), and only in HC exercise was there evidence of a coincident increase with time in integrated EMG of the vastus medialis and rectus femoris muscles (P < 0.05) with no change in mean power frequency. The phase 2 time constant was slower in HC [24.0 +/- 1.7 (SE) s] than in HE (14.7 +/- 2.8 s) and LC (16.7 +/- 2.2 s) exercise, while it was not different from MC exercise (20.6 +/- 2.1 s). These results show that the rate of increase in VO2 at the onset of exercise was not different between HE and LC exercise, where the metabolic demand was similar, but both had significantly faster kinetics for VO2 than HC exercise. The VO2 slow component might be related to increased muscle activation, which is a function of metabolic demand and not absolute work rate.  相似文献   

10.
The objective of the present study was to compare pulmonary gas exchange kinetics (VO2 kinetics) and time to exhaustion (Tlim) between trained and untrained individuals during severe exercise performed on a cycle ergometer and treadmill. Eleven untrained males in running (UR) and cycling (UC), nine endurance cyclists (EC), and seven endurance runners (ER) were submitted to the following tests on separate days: (i) incremental test for determination of maximal oxygen uptake (VO2max) and the intensity associated with the achievement of VO2max (IVO2max) on a mechanical braked cycle ergometer (EC and UC) and on a treadmill (ER and UR); (ii) all-out exercise bout performed at IVO2max to determine the time to exhaustion at IVO2max (Tlim) and the time constant of oxygen uptake kinetics (tau). The tau was significantly faster in trained group, both in cycling (EC = 28.2 +/- 4.7s; UC = 63.8 +/- 25.0s) and in running (ER = 28.5 +/- 8.5s; UR = 59.3 +/- 12.0s). Tlim of untrained was significantly lower in cycling (EC = 384.4 +/- 66.6s vs. UC; 311.1 +/- 105.7 s) and higher in running (ER = 309.2 +/- 176.6 s vs. UR = 439.8 +/- 104.2 s). We conclude that the VO2 kinetic response at the onset of severe exercise, carried out at the same relative intensity is sensitive to endurance training, irrespective of the exercise type. The endurance training seems to differently influence Tlim during exercise at IVO2max in running and cycling.  相似文献   

11.
Despite many reports of long-lasting elevation of metabolism after exercise, little is known regarding the effects of exercise intensity and duration on this phenomenon. This study examined the effect of a constant duration (30 min) of cycle ergometer exercise at varied intensity levels [50 and 70% of maximal O2 consumption (VO2max)] on 3-h recovery of oxygen uptake (VO2). VO2 and respiratory exchange ratios were measured by open-circuit spirometry in five trained female cyclists (age 25 +/- 1.7 yr) and five untrained females (age 27 +/- 0.8 yr). Postexercise VO2 measured at intervals for 3 h after exercise was greater (P less than 0.01) after exercise at 50% VO2max in trained (0.40 +/- 0.01 l/min) and untrained subjects (0.39 +/- 0.01 l/min) than after 70% VO2max in (0.31 +/- 0.02 l/min) and untrained subjects (0.29 +/- 0.02 l/min). The lower respiratory exchange ratio values (P less than 0.01) after 50% VO2max in trained (0.78 +/- 0.01) and untrained subjects (0.80 +/- 0.01) compared with 70% VO2max in trained (0.81 +/- 0.01) and untrained subjects (0.83 +/- 0.01) suggest that an increase in fat metabolism may be implicated in the long-term elevation of metabolism after exercise. This was supported by the greater estimated fatty acid oxidation (P less than 0.05) after 50% VO2max in trained (147 +/- 4 mg/min) and untrained subjects (133 +/- 9 mg/min) compared with 70% VO2max in trained (101 +/- 6 mg/min) and untrained subjects (85 +/- 7 mg/min).  相似文献   

12.
Slow upward drift of VO2 during constant-load cycling in untrained subjects   总被引:2,自引:0,他引:2  
The oxygen uptake kinetics during constant-load exercise when sitting on a bicycle ergometer were determined in 7 untrained subjects by measuring breath-by-breath VO2 during continuous exercise to volitional exhaustion (mean endurance time = 1160 +/- 172 s) at a pedal frequency of 70 revolutions.min-1. The power output, averaging 189.5 W, was set at 82.5% of that eliciting the individual VO2max during a 5 min incremental exercise test. Throughout the exercise period, the VO2 kinetics could be appropriately described by a two-component exponential equation of the form: VO2(t) = Ya[1 - exp(-kat)] + Yb[1 - exp(-kbt)] where VO2 is net oxygen consumption and t the time from work onset. VO2 measured at the end of exercise was close to VO2max (98% VO2max) and the mean values of Ya, ka, Yb and kb amounted to 1195 ml O2.min-1, 0.034 s-1, 1562 ml O2.min-1, and 0.005 s-1 respectively. The initial rate of increase in VO2 predicted from the above equation is slower than that calculated, for the same work intensity, on the basis of the data obtained by Morton (1985) in trained subjects. For t greater than 480 s, however, the two models yield substantially equal results.  相似文献   

13.
The quantification of maximum oxygen uptake (V(O2 max)), a parameter characterizing the effective integration of the neural, cardiopulmonary, and metabolic systems, requires oxygen uptake (VO2) to attain a plateau. We were interested in whether a VO2 plateau was consistently manifest during maximal incremental ramp cycle ergometry and also in ascertaining the relationship between this peak VO2 (V(O2 peak)) and that determined from one, or several, maximal constant-load tests. Ventilatory and pulmonary gas-exchange variables were measured breath by breath with a turbine and mass spectrometer. On average, V(O2 peak) [3.51 +/- 0.8 (SD) l/min] for the ramp test did not differ from that extrapolated from the linear phase of the response in 71 subjects. In 12 of these subjects, the V(O2 peak) was less than the extrapolated value by 0.1-0.4 l/min (i.e., a "plateau"), and in 19 subjects, V(O2 peak) was higher by 0.05-0.4 l/min. In the remaining 40 subjects, we could not discriminate a difference. The V(O2 peak) from the incremental test also did not differ from that of a single maximum constant-load test in 38 subjects or from the V(O2 max) in 6 subjects who undertook a range of progressively greater discontinuous constant-load tests. A plateau in the actual VO2 response is therefore not an obligatory consequence of incremental exercise. Because the peak value attained was not different from the plateau in the plot of VO2 vs. work rate (for the constant-load tests), the V(O2 peak) attained on a maximum-effort incremental test is likely to be a valid index of V(O2 max), despite no evidence of a plateau in the data themselves. However, without additional tests, one cannot be certain.  相似文献   

14.
The purpose of this study was to investigate the relationship between anaerobic threshold (Th(an)) and muscle fatigue threshold (EMGFT) as estimated from electromyographic (EMG) data taken from the quadriceps muscles (vastus lateralis) during exercise on a cycle ergometer. The subjects in this study were 20 female college students, including highly trained endurance athletes and untrained sedentary individuals, whose fitness levels derived from their maximal oxygen consumption ranged from 24.9 to 62.2 ml.kg-1.min-1. The rate of increase in integrated EMG (iEMG) activity as a function of time (iEMG slope) was calculated at each of four constant power outputs (350, 300, 250, 200 W), sufficiently high to bring about muscle fatigue. The iEMG slopes so obtained were plotted against the exercise intensities imposed, resulting in linear plots which were extrapolated to zero slope to give an intercept on the power axis which was in turn interpreted as the highest exercise intensity sustainable without electromyographic evidence of neuromuscular fatigue (EMGFT). The Th(an) was estimated from gas exchange parameters during an incremental exercise test on the same cycle ergometer. The mean results indicated that oxygen uptake (VO2) at Than was 1.39 l.min-1, SD 0.44 and VO2 at EMGFT was 1.33 l.min-1, SD 0.57. There was no significant difference between these mean values (P greater than 0.05) and there was a highly significant correlation between VO2 at Than and VO2 at EMGFT (r = 0.823, P less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

15.
The mechanisms responsible for the oxygen uptake (VO2) slow component during high-intensity exercise have yet to be established. In order to explore the possibility that the VO2 slow component is related to the muscle contraction regimen used, we examined the pulmonary VO2 kinetics during constant-load treadmill and cycle exercise at an exercise intensity that produced the same level of lactacidaemia for both exercise modes. Eight healthy subjects, aged 22-37 years, completed incremental exercise tests to exhaustion on both a cycle ergometer and a treadmill for the determination of the ventilatory threshold (defined as the lactate threshold, Th1a) and maximum VO2 (VO2max). Subsequently, the subjects completed two "square-wave" transitions from rest to a running speed or power output that required a VO2 that was halfway between the mode-specific Th1a and VO2max. Arterialised blood lactate concentration was determined immediately before and after each transition. The VO2 responses to the two transitions for each exercise mode were time-aligned and averaged. The increase in blood lactate concentration produced by the transitions was not significantly different between cycling [mean (SD) 5.9 (1.5) mM] and running [5.5 (1.6) mM]. The increase in VO2 between 3 and 6 min of exercise; (i.e. the slow component) was significantly greater in cycling than in running, both in absolute terms [290 (102) vs 200 (45) ml x min(-1); P<0.05] and as a proportion of the total VO2 response above baseline [10 (3)% vs 6 (1)%; P < 0.05]. These data indicate that: (a) a VO2 slow component does exist for high-intensity treadmill running, and (b) the magnitude of the slow component is less for running than for cycling at equivalent levels of lactacidaemia. The greater slow component observed in cycling compared to running may be related to differences in the muscle contraction regimen that is required for the two exercise modes.  相似文献   

16.
To test the hypothesis that pyruvate dehydrogenase (PDH) is differentially regulated in specific human muscles, regulation of PDH was examined in triceps, deltoid, and vastus lateralis at rest and during intense exercise. To elicit considerable glycogen use, subjects performed 30 min of exhaustive arm cycling on two occasions and leg cycling exercise on a third day. Muscle biopsies were obtained from deltoid or triceps on the arm exercise days and from vastus lateralis on the leg cycling day. Resting PDH protein content and phosphorylation on PDH-E1 alpha sites 1 and 2 were higher (P < or = 0.05) in vastus lateralis than in triceps and deltoid as was the activity of oxidative enzymes. Net muscle glycogen utilization was similar in vastus lateralis and triceps ( approximately 50%) but less in deltoid (likely reflecting less recruitment of deltoid), while muscle lactate accumulation was approximately 55% higher (P < or = 0.05) in triceps than vastus lateralis. Exercise induced (P < or = 0.05) dephosphorylation of both PDH-E1 alpha site 1 and site 2 in all three muscles, but it was more pronounced at PDH-E1 alpha site 1 in triceps than in vastus lateralis (P < or = 0.05). The increase in activity of the active form of PDH (PDHa) after 10 min of exercise was more marked in vastus lateralis ( approximately 246%) than in triceps ( approximately 160%), but when it was related to total PDH-E1 alpha protein content, no difference was evident. In conclusion, PDH protein content seems to be related to metabolic enzyme profile, rather than myosin heavy chain composition, and less PDH capacity in triceps is a likely contributing factor to higher lactate accumulation in triceps than in vastus lateralis.  相似文献   

17.
This study examined the ability of well-trained eumenorrheic women to increase muscle glycogen content and endurance performance in response to a high-carbohydrate diet (HCD; approximately 78% carbohydrate) compared with a moderate-carbohydrate diet (MD; approximately 48% carbohydrate) when tested during the luteal phase of the menstrual cycle. Six women cycled to exhaustion at approximately 80% maximal oxygen uptake (VO(2 max)) after each of the randomly assigned diet and exercise-tapering regimens. A biopsy was taken from the vastus lateralis before and after exercise in each trial. Preexercise muscle glycogen content was high after the MD (625.2 +/- 50.1 mmol/kg dry muscle) and 13% greater after the HCD (709.0 +/- 44.8 mmol/kg dry muscle). Postexercise muscle glycogen was low after both trials (MD, 91.4 +/- 34.5; HCD, 80.3 +/- 19.5 mmol/kg dry muscle), and net glycogen utilization during exercise was greater after the HCD. The subjects also cycled longer at approximately 80% VO(2 max) after the HCD vs. MD (115:31 +/- 10:47 vs. 106:35 +/- 8:36 min:s, respectively). In conclusion, aerobically trained women increased muscle glycogen content in response to a high-dietary carbohydrate intake during the luteal phase of the menstrual cycle, but the magnitude was smaller than previously observed in men. The increase in muscle glycogen, and possibly liver glycogen, after the HCD was associated with increased cycling performance to volitional exhaustion at approximately 80% VO(2 max).  相似文献   

18.
AIM: This study examined the electromyographic (EMG) activity of knee extensor agonists and a knee extensor antagonist muscle during fatiguing isometric extensions across a range of force levels. METHODS: Five female subjects performed isometric knee extensions at 25%, 50%, 75% and 100% of their maximal voluntary contraction (MVC) with the knee flexed to 75 degrees. Surface EMG (SEMG) was recorded with bipolar electrodes from the vastus lateralis (VL), vastus medialis (VM), rectus femoris (RF) and biceps femoris (BF) and the root-mean-squared (RMS) amplitude and the percentage frequency compression of these recordings were calculated. Commonality and cross talk between recordings were also examined. RESULTS: Cross talk between recordings was deemed negligible despite significant levels of commonality between the agonist and antagonist SEMG, which was attributed to common drive. SEMG RMS amplitude increased significantly for all muscles during the 25%, 50%, 75% MVC knee extensions until task failure, and decreased significantly for 100% MVC. The frequency spectrum of the SEMG compressed significantly for all muscles and % MVC levels. The VM, VL and BF SEMG recordings responded similarly to fatigue. The RF's frequency spectrum compressed to a significantly higher degree. CONCLUSIONS: The VM, VL, RF, and BF fatigue in parallel, with high similarity between VM, VL and BF, giving support to the concept of a shared agonist-antagonist motoneuron pool.  相似文献   

19.
The surface electromyogram (EMG) from active muscle and oxygen uptake (VO2) were studied simultaneously to examine changes of motor unit (MU) activity during exercise tests with different ramp increments. Six male subjects performed four exhausting cycle exercises with different ramp slopes of 10, 20, 30 and 40 W.min-1 on different days. The EMG signals taken from the vastus lateralis muscle were stored on a digital data recorder and converted to obtain the integrated EMG (iEMG). The VO2 was measured, with 20-s intervals, by the mixing chamber method. A non-linear increase in iEMG against work load was observed for each exercise in all subjects. The break point of the linear relationship of iEMG was determined by the crossing point of the two regression lines (iEMGbp). Significant differences were obtained in the exercise intensities corresponding to maximal oxygen uptake (VO2max) and the iEMGbp between 10 and 30, and 10 and 40 W.min-1 ramp exercises (P < 0.05). However, no significant differences were obtained in VO2max and VO2 corresponding to the iEMGbp during the four ramp exercises. With respect to the relationship between VO2 and exercise intensity during the ramp increments, the VO2-exercise intensity slope showed significant differences only for the upper half (i.e. above iEMGbp). These results demonstrated that the VO2max and VO2 at which a nonlinear increase in iEMG was observed were not varied by the change of ramp slopes but by the exercise intensity corresponding to VO2max and the iEMGbp was varied by the change of ramp slopes.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

20.
Exercise performed above the lactate threshold (OLa) produces a slowly-developing phase of oxygen uptake (VO2) kinetics which elevates VO2 above that predicted from the sub-OLa VO2-work rate relationship. This phenomenon has only been demonstrated, to date, in subjects who were relatively homogeneous with respect to fitness. This investigation therefore examined whether this behaviour occurred at a given absolute VO2 or whether it was a characteristic of supra-OLa exercise in a group of subjects with over a threefold range of OLa (990-3000 ml O2.min-1) and peak VO2 (1600-5260 ml O2.min-1). Twelve healthy subjects performed: 1) exhausting incremental cycle ergometer exercise for estimation of OLa (OLa) and peak VO2, and 11) a series of constant-load tests above and below OLa for determination of the VO2 profile and efficiency of work. During all tests expired ventilation, VO2 and carbon dioxide production were monitored breath-by-breath. The efficiency of work determined during incremental exercise (28.1 +/- 0.7%, means +/- SE, n = 12) did not differ from that determined during sub-OLa constant-load exercise (27.4 +/- 0.5%, p greater than 0.05). For constant-load exercise, VO2 rose above that predicted, from the sub-OLa VO2-work rate relationship, for all supra-OLa work rates. This was evident above 990 ml O2.min-1 in the least fit subject but only above 3000 ml O2.min-1 in the fittest subject. As a consequence the efficiency of work was reduced from 27.4 +/- 0.5% for sub-OLa exercise to 22.6 +/- 0.4% (p less than 0.05) at the lowest supra-OLa work rate (i.e. OLa + 20 W, on average).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号