首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Survey of the year 2003 commercial optical biosensor literature   总被引:3,自引:0,他引:3  
In the year 2003 there was a 17% increase in the number of publications citing work performed using optical biosensor technology compared with the previous year. We collated the 962 total papers for 2003, identified the geographical regions where the work was performed, highlighted the instrument types on which it was carried out, and segregated the papers by biological system. In this overview, we spotlight 13 papers that should be on everyone's 'must read' list for 2003 and provide examples of how to identify and interpret high-quality biosensor data. Although we still find that the literature is replete with poorly performed experiments, over-interpreted results and a general lack of understanding of data analysis, we are optimistic that these shortcomings will be addressed as biosensor technology continues to mature.  相似文献   

2.
Survey of the year 2005 commercial optical biosensor literature   总被引:5,自引:0,他引:5  
We identified 1113 articles (103 reviews, 1010 primary research articles) published in 2005 that describe experiments performed using commercially available optical biosensors. While this number of publications is impressive, we find that the quality of the biosensor work in these articles is often pretty poor. It is a little disappointing that there appears to be only a small set of researchers who know how to properly perform, analyze, and present biosensor data. To help focus the field, we spotlight work published by 10 research groups that exemplify the quality of data one should expect to see from a biosensor experiment. Also, in an effort to raise awareness of the common problems in the biosensor field, we provide side-by-side examples of good and bad data sets from the 2005 literature.  相似文献   

3.
4.
Survey of the year 2001 commercial optical biosensor literature   总被引:3,自引:0,他引:3  
We have assembled references of 700 articles published in 2001 that describe work performed using commercially available optical biosensors. To illustrate the technology's diversity, the citation list is divided into reviews, methods and specific applications, as well as instrument type. We noted marked improvements in the utilization of biosensors and the presentation of kinetic data over previous years. These advances reflect a maturing of the technology, which has become a standard method for characterizing biomolecular interactions.  相似文献   

5.
Survey of the year 2004 commercial optical biosensor literature   总被引:4,自引:0,他引:4  
The year 2004 represents a milestone for the biosensor research community: in this year, over 1000 articles were published describing experiments performed using commercially available systems. The 1038 papers we found represent an approximately 10% increase over the past year and demonstrate that the implementation of biosensors continues to expand at a healthy pace. We evaluated the data presented in each paper and compiled a 'top 10' list. These 10 articles, which we recommend every biosensor user reads, describe well-performed kinetic, equilibrium and qualitative/screening studies, provide comparisons between binding parameters obtained from different biosensor users, as well as from biosensor- and solution-based interaction analyses, and summarize the cutting-edge applications of the technology. We also re-iterate some of the experimental pitfalls that lead to sub-optimal data and over-interpreted results. We are hopeful that the biosensor community, by applying the hints we outline, will obtain data on a par with that presented in the 10 spotlighted articles. This will ensure that the scientific community at large can be confident in the data we report from optical biosensors.  相似文献   

6.
Survey of the year 2000 commercial optical biosensor literature.   总被引:7,自引:0,他引:7  
We have compiled a comprehensive list of the articles published in the year 2000 that describe work employing commercial optical biosensors. Selected reviews of interest for the general biosensor user are highlighted. Emerging applications in areas of drug discovery, clinical support, food and environment monitoring, and cell membrane biology are emphasized. In addition, the experimental design and data processing steps necessary to achieve high-quality biosensor data are described and examples of well-performed kinetic analysis are provided.  相似文献   

7.
We took a different approach to reviewing the commercial biosensor literature this year by inviting 22 biosensor users to serve as a review committee. They set the criteria for what to expect in a publication and ultimately decided to use a pass/fail system for selecting which papers to include in this year's reference list. Of the 1514 publications in 2009 that reported using commercially available optical biosensor technology, only 20% passed their cutoff. The most common criticism the reviewers had with the literature was that "the biosensor experiments could have been done better." They selected 10 papers to highlight good experimental technique, data presentation, and unique applications of the technology. This communal review process was educational for everyone involved and one we will not soon forget.  相似文献   

8.
A survey of the year 2002 commercial optical biosensor literature   总被引:2,自引:0,他引:2  
We have compiled 819 articles published in the year 2002 that involved commercial optical biosensor technology. The literature demonstrates that the technology's application continues to increase as biosensors are contributing to diverse scientific fields and are used to examine interactions ranging in size from small molecules to whole cells. Also, the variety of available commercial biosensor platforms is increasing and the expertise of users is improving. In this review, we use the literature to focus on the basic types of biosensor experiments, including kinetics, equilibrium analysis, solution competition, active concentration determination and screening. In addition, using examples of particularly well-performed analyses, we illustrate the high information content available in the primary response data and emphasize the impact of including figures in publications to support the results of biosensor analyses.  相似文献   

9.
Optical biosensor technology continues to be the method of choice for label‐free, real‐time interaction analysis. But when it comes to improving the quality of the biosensor literature, education should be fundamental. Of the 1413 articles published in 2008, less than 30% would pass the requirements for high‐school chemistry. To teach by example, we spotlight 10 papers that illustrate how to implement the technology properly. Then we grade every paper published in 2008 on a scale from A to F and outline what features make a biosensor article fabulous, middling or abysmal. To help improve the quality of published data, we focus on a few experimental, analysis and presentation mistakes that are alarmingly common. With the literature as a guide, we want to ensure that no user is left behind. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
Reliable kinetic estimates can be obtained from significantly less data than is commonly used today, particularly in the characterization of 1:1 interactions involving low molecular weight compounds and proteins. We have designed a rational and cost-effective strategy to determine kinetic constants using Biacore's surface plasmon resonance-based biosensors and show that the number of measurements necessary for accurate kinetic determinations can be greatly reduced, increasing sample throughput and saving sample material. Simulated and measured data for a range of possible 1:1 interactants were studied to find the minimum requirements of a data set for kinetic analysis. The results showed that kinetic constants in the region 10(4) < k(a) < 10(7) M(-1) s(-1) (association) and 10(-4) < k(d) < 10(-1) s(-1) (dissociation) could easily be determined in a 1:1 interaction model. Owing to the information-dense nature of Biacore data, only two sample concentrations were necessary to reliably determine the kinetics. A standard sample concentration series consisting of 10-fold dilutions between approximately 10 microM and approximately 1 nM consistently provided at least two concentrations with sufficient information about the interaction in this region. Determinations of the constants became increasingly unreliable outside this region. If the rate constants prove to be outside the specified region or the data fits poorly to the 1:1-MTL model, more experiments are required. General recommendations for the design of a cost-effective assay to deliver reliable kinetic measurements are provided.  相似文献   

11.
The interaction between two different monoclonal antibodies (Mabs) and their corresponding bispecific antibodies (Babs) with immobilized antigens was investigated using an optical biosensor (IAsys). The analyzed panel of affinity-purified antibodies included two parental Mabs (one of which was specific to human IgG (hIgG), and another one to horseradish peroxidase (HRP)), as well as Babs derived thereof (anti-hIgG/HRP). Babs resulting from the fusion of parental hybridomas bear two antigen-binding sites toward two different antigens and thus may interact with immobilized antigen through only one antigen-binding site (monovalently). Using an IAsys biosensor this study shows that the bivalent binding of Mabs predominates over the monovalent binding with immobilized HRP, whereas anti-hIgG parental Mabs were bound monovalently to the immobilized hIgG. The observed equilibrium association constant (K ass) values obtained in our last work [1] by solid-phase radioimmunoassay are consistent with those constants obtained by IAsys. The K ass of anti-HRP Mabs was about 50 times higher than that of anti-HRP shoulder of Babs. The dissociation rate constant (k diss) for anti-HRP shoulder of Babs was 21 times higher than k diss for anti-HRP Mabs. The comparison of the kinetic parameters for bivalent anti-HRP Mabs and Babs derived from anti-Mb/HRP and anti-hIgG/HRP, allowed to calculate that 95% of bound anti-HRP Mabs are bivalently linked with immobilized HRP, whereas only 5% of bound anti-HRP Mabs are monovalently linked. In general, the data obtained indicate that Babs bearing an enzyme-binding site may not be efficiently used instead of traditional antibody–enzyme conjugates in the case of binding of bivalent Mabs.  相似文献   

12.
Optical biosensors are finding increasing use in the determination of kinetic and equilibrium constants for a variety of biomolecular interactions. Usually these biosensors require one biomolecule, the ligand, to be covalently attached to a hydrogel matrix which itself is bonded to the sensing surface. The ligands partner, the ligate, then binds from solution resulting in a measurable change in response which the instrument records as a function of time. Although in many cases, optical biosensors are used in order to obtain parameters that relate to interactions in solution, it is becoming clear that measurements involving the interaction of ligate with immobilized ligands on surfaces require careful experimental design. Here we report on how the density of ligand loading within the hydogel matrix affects the measured interaction kinetics. It is found that crowding of ligand within this matrix results in a significant reduction in the measured association rate constant, with a corresponding effect in the calculated overall affinity. However, measurements at low ligand loadings show association rate constants that are comparable to those measured in solution. Clearly, where this comparison is required, it is important to perform measurements under such conditions. © 1997 John Wiley & Sons, Ltd.  相似文献   

13.
Over the last decade isothermal titration calorimetry (ITC) has developed from a specialist method which was largely restricted in its use to dedicated experts, to a major, commercially available tool in the arsenal directed at understanding molecular interactions. The number of those proficient in this field has multiplied dramatically, as has the range of experiments to which this method has been applied. This has led to an overwhelming amount of new data and novel applications to be assessed. With the increasing number of publications in this field comes a need to highlight works of interest and impact. In this overview of the literature we have attempted to draw attention to papers and issues for which both the experienced calorimetrist and the interested dilettante hopefully will share our enthusiasm.  相似文献   

14.
Isothermal titration calorimetry (ITC) is becoming widely accepted as a key instrument in any laboratory in which quantification of biomolecular interactions is a requisite. The method has matured with respect to general acceptance and application development over recent years. The number of publications on ITC has grown exponentially over the last 10 years, reflecting the general utility of the method. Here all the published works of the year 2002 in this area have been surveyed. We review the broad range of systems to which ITC is being directed and classify these into general areas highlighting key publications of interest. This provides an overview of what can be achieved using this method and what developments are likely to occur in the near future.  相似文献   

15.
The market for commercially available isothermal titration calorimeters continues to grow as new applications and methodologies are developed. Concomitantly the number of users (and abusers) increases dramatically, resulting in a steady increase in the number of publications in which isothermal titration calorimetry (ITC) plays a role. In the present review, we will focus on areas where ITC is making a significant contribution and will highlight some interesting applications of the technique. This overview of papers published in 2004 also discusses current issues of interest in the development of ITC as a tool of choice in the determination of the thermodynamics of molecular recognition and interaction.  相似文献   

16.
Human cytomegalovirus (CMV) is a large enveloped virus that encodes multiple glycoproteins required for virus-cell binding and fusion. To assess the binding properties of antibodies with target glycoprotein in a natural context of infection, we investigated the feasibility of using the surface plasmon resonance (SPR) technique for studying the direct binding of antibodies with CMV virions. Direct immobilization of whole virions to sensor surface and a surface regeneration procedure allowed for quantitative and reproducible measurements of binding affinity and binding kinetics of antibody–whole virion interactions. The conformational and functional integrity of viral particles was not compromised by the regeneration condition as evaluated with antibodies recognizing conformational epitopes and by electron microscopy. Binding of an irrelevant antibody was not observed, indicating the high specificity of the method. A panel of anti-gB antibodies was measured and the binding affinities correlated fairly well with those determined by ELISA. These data demonstrated that the interaction of anti-gB antibody with whole virion of large enveloped CMV can be quantitatively studied using SPR. This method has been successfully applied for screening and selection of anti-CMV antibodies and can be potentially extended to study antibody–glycoprotein interactions of other related herpesviruses.  相似文献   

17.
In steroid hydroxylation system in adrenal cortex mitochondria, NADPH-adrenodoxin reductase (AR) and adrenodoxin (Adx) form a short electron-transport chain that transfers electrons from NADPH to cytochromes P-450 through FAD in AR and [2Fe-2S] cluster in Adx. The formation of [AR/Adx] complex is essential for the electron transfer mechanism in which previous studies suggested that AR tryptophan (Trp) residue(s) might be implicated. In this study, we modified AR Trps by N-bromosuccinimide (NBS) and studied AR binding to Adx by a resonant mirror biosensor. Chemical modification of tryptophans caused inhibition of electron transport. The modified protein (AR*) retained the native secondary structure but showed a lower affinity towards Adx with respect to AR. Activity measurements and fluorescence data indicated that one Trp residue of AR may be involved in the electron transferring activity of the protein. Computational analysis of AR and [AR/Adx] complex structures suggested that Trp193 and Trp420 are the residues with the highest probability to undergo NBS-modification. In particular, the modification of Trp420 hampers the correct reorientation of AR* molecule necessary to form the native [AR/Adx] complex that is catalytically essential for electron transfer from FAD in AR to [2Fe-2S] cluster in Adx. The data support an incorrect assembly of [AR*/Adx] complex as the cause of electron transport inhibition.  相似文献   

18.
Since the publication of the original review of piezoelectric acoustic sensors in this series there has been a consistent, gradual expansion in the number of published papers using 'quartz crystal microbalances' (QCM). Between 2001 and 2009, the number of QCM publications per annum has increased from 49 to 273, with a two-fold increase in papers per annum between 2004 and 2008. Within the field, comparing the time covered by the current to the previous review, there are trends towards increasing use of QCM in the study of protein adsorption to surfaces (93% increase), homeostasis (67% increase), protein-protein interactions (40% increase) and carbohydrates (43% increase). New commercial systems have been released that are driving the uptake of the technology for characterization of binding specificities, affinities, kinetics and conformational changes associated with a molecular recognition event. This paper highlights theoretical and practical aspects of the principles that underpin acoustic analysis, then reviews exemplary papers in key application areas involving small molecular weight ligands, carbohydrates, proteins, nucleic acids, viruses, bacteria, cells and membrane interfaces.  相似文献   

19.
20.
The widespread exploitation of biosensors in the analysis of molecular recognition has its origins in the mid-1990s following the release of commercial systems based on surface plasmon resonance (SPR). More recently, platforms based on piezoelectric acoustic sensors (principally 'bulk acoustic wave' (BAW), 'thickness shear mode' (TSM) sensors or 'quartz crystal microbalances' (QCM)), have been released that are driving the publication of a large number of papers analysing binding specificities, affinities, kinetics and conformational changes associated with a molecular recognition event. This article highlights salient theoretical and practical aspects of the technologies that underpin acoustic analysis, then reviews exemplary papers in key application areas involving small molecular weight ligands, carbohydrates, proteins, nucleic acids, viruses, bacteria, cells and lipidic and polymeric interfaces. Key differentiators between optical and acoustic sensing modalities are also reviewed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号