1.
Although the relationship between contact area and pressure under physiological loading has been described in the feline patellofemoral joint, this interaction has only been examined under simplified loading conditions and/or considerably lower forces than those occurring during demanding activities in humans. We hypothesized that patellofemoral contact area increases non-linearly under an increasing joint reaction force to regulate patellofemoral pressure. Eight human cadaveric knees were ramp loaded with muscle forces representative of the stance phase of stair climbing at 30° knee flexion. Continuous pressure data were acquired with a pressure sensitive film that was positioned within the patellofemoral joint. While pressure was linearly dependent upon the resulting joint reaction force, contact area asymptotically approached a maximum value and reached 95% of this maximum at patellofemoral forces of 349–723 N (95% CI). Our findings indicate that the regulatory influence of increasing contact area to protect against high patellofemoral pressure is exhausted at relatively low loads.  相似文献   

2.
The purposes of this study were to determine the in situ functional and material properties of articular cartilage in an experimental model of joint injury, and to quantify the corresponding in situ joint contact mechanics. Experiments were performed in the anterior cruciate ligament (ACL) transected knee of the cat and the corresponding, intact contralateral knee, 16 weeks following intervention. Cartilage thickness, stiffness, effective Young’s modulus, and permeability were measured and derived from six locations of the knee. The total contact area and peak pressures in the patellofemoral joint were obtained in situ using Fuji Pressensor film, and comparisons between experimental and contralateral joint were made for corresponding loading conditions. Total joint contact area and peak pressure were increased and decreased significantly (=0.01), respectively, in the experimental compared to the contralateral joint. Articular cartilage thickness and stiffness were increased and decreased significantly (=0.01), respectively, in the experimental compared to the contralateral joint in the four femoral and patellar test locations. Articular cartilage material properties (effective Young’s modulus and permeability) were the same in the ACL-transected and intact joints. These results demonstrate for the first time the effect of changes in articular cartilage properties on the load transmission across a joint. They further demonstrate a substantial change in the joint contact mechanics within 16 weeks of ACL transection. The results were corroborated by theoretical analysis of the contact mechanics in the intact and ACL-transected knee using biphasic contact analysis and direct input of cartilage properties and joint surface geometry from the experimental animals. We conclude that the joint contact mechanics in the ACL-transected cat change within 16 weeks of experimental intervention.  相似文献   

3.
One possible cause of patellofemoral pain syndrome is excessive lateral force acting on the patella. Although several treatment methods focus on decreasing the lateral force acting on the patella, the relationship between the lateral force and the patellofemoral contact pressure distribution is unclear. A computational model has been developed to determine how loading variations alter the patellofemoral force and pressure distributions for individual knees. The model allows variation in the quadriceps and patella tendon forces, and calculates the predicted contact pressure distribution using the discrete element analysis technique. To characterize the accuracy of the model, four cadaver knees were flexed on a knee simulator with three initial Q-angles, while recording the force and pressure distributions with a pressure sensor. A model of each knee was created from CT data. Using the external force applied to the knee, the geometry of the knee, and the quadriceps origin as input, the pressure distribution was calculated during flexion. Similar trends were noted for the computational and experimental results. The percentage of the total force applied to the lateral cartilage increased with the Q-angle. The maximum contact pressure increased during flexion. The maximum lateral contact pressure increased with the Q-angle for three knees. For the other knee, increasing the Q-angle decreased the maximum lateral pressure. The maximum medial contact pressure decreased as the Q-angle increased. By characterizing the influence of patellofemoral loading on the force and pressure distributions, the computational model could be used to evaluate treatment methods prescribed for patellofemoral pain.  相似文献   

4.
The mechanical environment during stair climbing has been associated with patellofemoral pain, but the contribution of loading to this condition is not clearly understood. It was hypothesized that the loading conditions during stair climbing induce higher patellofemoral pressures, a more lateral force distribution on the trochlea and a more lateral shift and tilt of the patella compared to walking at early knee flexion. Optical markers for kinematic measurements were attached to eight cadaveric knees, which were loaded with muscle forces at instances of walking and stair climbing cycles at 12° and 30° knee flexion. Contact mechanics were determined using a pressure sensitive film. At 12° knee flexion, stair climbing loads resulted in higher peak pressure (p=0.012) than walking, more lateral force distribution (p=0.012) and more lateral tilt (p=0.012), whilst mean pressure (p=0.069) and contact area (p=0.123) were not significantly different. At 30° knee flexion, although stair climbing compared to walking loads resulted in significantly higher patellofemoral mean (p=0.012) and peak pressures (p=0.012), contact area (p=0.025), as well as tilt (p=0.017), the medial–lateral force distribution (p=0.674) was not significantly different. No significant differences were observed in patellar shift between walking and stair climbing at either 12° (p=0.093) or 30° (p=0.575) knee flexion. Stair climbing thus leads to more challenging patellofemoral contact mechanics and kinematics than level walking at early knee flexion. The increase in patellofemoral pressure, lateral force distribution and lateral tilt during stair climbing provides a possible biomechanical explanation for the patellofemoral pain frequently experienced during this activity.  相似文献   

5.
The mechanical environment is an important factor affecting the maintenance and adaptation of articular cartilage, and thus the function of the joint and the progression of joint degeneration. Recent evidence suggests that cartilage deformation caused by mechanical loading is directly associated with deformation and volume changes of chondrocytes. Furthermore, in vitro experiments have shown that these changes in the mechanical states of chondrocytes correlate with a change in the biosynthetic activity of cartilage cells. The purpose of this study was to apply our knowledge of contact forces within the feline patellofemoral joint to quantify chondrocyte deformation in situ under loads of physiological magnitude. A uniform, static load of physiological magnitude was applied to healthy articular cartilage still fully intact and attached to its native bone. The compressed cartilage was then chemically fixed to enable the evaluation of cartilage strain, chondrocyte deformation and chondrocyte volumetric fraction. Patella and femoral groove articular cartilages differ in thickness, chondrocyte aspect ratio, and chondrocyte volumetric fraction in both magnitude and depth distribution. Furthermore, when subjected to the same compressive loads, changes to all of these parameters differ in magnitude and depth distribution between patellar and femoral groove articular cartilage. This evidence suggests that significant chondrocyte deformation likely occurs during in vivo joint loading, and may influence chondrocyte biosynthetic activity. Furthermore, we hypothesise that the contrasts between patella and femoral groove cartilages may explain, in part, the site-specific progression of osteoarthritis in the patellofemoral joint of the feline anterior cruciate ligament transected knee.  相似文献   

6.
In order to assess the changes in talocrural joint contact stress after rotationplasty, 10 lower-leg cadaver specimens were axially loaded with 600 N and investigated in two loading situations: (1) Normal loading with a plantigrade foot; (2) in an equinus position of a simulated rotationplasty. Joint contact stress in the talar facet of the talocrural joint was determined with Fuji Prescale film cut to size and analyzed with digital image analysis for joint contact area, mean and peak pressure, contact force, and location of the load application on the trochlea tali. The results demonstrate a significant transfer on the loading zone to the posterior part of the talus (p = 0.005), a significant reduction of the contact area (p = 0.005) and force (p = 0.005), and a significant increase of the mean (p = 0.022) and maximum pressures (p = 0.013). These results indicate that the rotationplasty causes pronounced changes in joint loading characteristics.  相似文献   

7.
The knowledge of real-time in-vivo cartilage deformation is important for understanding of cartilage function and biomechanical factors that may relate to cartilage degeneration. This study investigated cartilage contact area and peak contact compressive strain of four healthy human ankle joints as a function of time using a combined magnetic resonance (MR) and dual-orthogonal fluoroscopic imaging technique. Each ankle was subjected to a different constant loading (between 700 and 820 N). The cartilage contact deformation was obtained from the first second to 300 s after the load was applied. In all ankle joints studied in this paper, contact strains increased to 24-38% at first 20 s after loading. Beyond 20 s, the change of cartilage contact deformation was relatively small and varied in a rate close to zero beyond 50 s. These data indicated that the cartilage contact areas and contact strain could raise dramatically right after loading and reach a relatively stable condition within 1 min after constant loading. The history of cartilage deformation determined in this study may provide a real-time boundary condition for 3D finite element simulation of in vivo cartilage contact stress in the joint as a function of time.  相似文献   

8.
The objective of this study was to assess how accurately and repeatably the Iscan system measures force and pressure in the natural patellofemoral joint. These measurements must be made to test widely held assumptions about the relationships between mechanics, pain and cartilage degeneration. We assessed the system's accuracy by using test rigs in a materials testing machine to apply known forces and force distributions across the sensor. The root mean squared error in measuring resultant force (for five trials at each of seven load levels) was 6.5±4.4% (mean±standard deviation over all trials at all load levels), while the absolute error was −5.5±5.6%. For force distribution, the root mean squared error (for five trials at each of five force distributions) was 0.86±0.58%, while the absolute error was −0.22±1.03%. We assessed the repeatability of the system's measurements of patellofemoral contact force, pressure and force distribution in four cadaver specimens loaded in continuous and static flexion. Variability in measurement (standard deviation expressed as a percentage of the mean) was 9.1% for resultant force measurements and 3.0% for force distribution measurements for static loads, and 7.3% for resultant force and 2.2% for force distribution measurements for continuous flexion. Cementing the sensor to the cartilage lowered readings of resultant force by 31±32% (mean±standard deviation), area by 24±13% and mean pressure by 9±34% (relative to the uncemented sensor). Maximum pressure measurement, however, was 24±43% higher in the cemented sensor than in the uncemented sensor. The results suggest that the sensor measures force distribution more accurately and repeatably than absolute force. A limitation of our work, however, is that the sensor must be cemented to the patellar articular surface to make the force distribution measurements, and our results suggest that this process reduces the accuracy of force, pressure and area measurements. Our results suggest that the Iscan system's pressure measurement accuracy and repeatability are comparable to that of Fuji Prescale film, but its advantages are that it is thinner than most Fuji Prescale film, it measures contact area more accurately and that it makes continuous measurements of force, pressure and area.  相似文献   

9.
Finite element methods have been applied to evaluate in vivo joint behavior, new devices, and surgical techniques but have typically been applied to a small or single subject cohort. Anatomic variability necessitates the use of many subject-specific models or probabilistic methods in order to adequately evaluate a device or procedure for a population. However, a fully deformable finite element model can be computationally expensive, prohibiting large multisubject or probabilistic analyses. The aim of this study was to develop a group of subject-specific models of the patellofemoral joint and evaluate trade-offs in analysis time and accuracy with fully deformable and rigid body articular cartilage representations. Finite element models of eight subjects were used to tune a pressure-overclosure relationship during a simulated deep flexion cycle. Patellofemoral kinematics and contact mechanics were evaluated and compared between a fully deformable and a rigid body analysis. Additional eight subjects were used to determine the validity of the rigid body pressure-overclosure relationship as a subject-independent parameter. There was good agreement in predicted kinematics and contact mechanics between deformable and rigid analyses for both the tuned and test groups. Root mean square differences in kinematics were less than 0.5 deg and 0.2 mm for both groups throughout flexion. Differences in contact area and peak and average contact pressures averaged 5.4%, 9.6%, and 3.8%, respectively, for the tuned group and 6.9%, 13.1%, and 6.4%, respectively, for the test group, with no significant differences between the two groups. There was a 95% reduction in computational time with the rigid body analysis as compared with the deformable analysis. The tuned pressure-overclosure relationship derived from the patellofemoral analysis was also applied to tibiofemoral (TF) articular cartilage in a group of eight subjects. Differences in contact area and peak and average contact pressures averaged 8.3%, 11.2%, and 5.7% between rigid and deformable analyses in the tibiofemoral joint. As statistical, probabilistic, and optimization techniques can require hundreds to thousands of analyses, a viable platform is crucial to component evaluation or clinical applications. The computationally efficient rigid body platform described in this study may be integrated with statistical and probabilistic methods and has potential clinical application in understanding in vivo joint mechanics on a subject-specific or population basis.  相似文献   

10.
The aim of the present study was to evaluate retropatellar contact characteristics at different angles of flexion of the knee joint. To this end, 6 cadaveric legs were examined using pressure sensitive film (Fuji Prescale type "super low") at angles of flexion of 45 degrees, 60 degrees, 90 degrees and 120 degrees both in neutral rotation and 10 degrees internal and external rotation of the femur in the same knee joints. A force of 140 N was applied to both the vastus medialis and lateralis, and a comparison made with a medially and a laterally dominating muscle force. The contact areas decreased with increasing angles of flexion. The medially dominating muscle traction increased the contact area. Comparison between internal and external rotation revealed a decrease in contact area on internal rotation. The pressure measurements were comparable in all loading situations. Comparison between neutral and medial traction revealed significant differences in contact area, pressure and force. The influence of femoral rotation showed no significant difference. A comparison of the different angles of flexion revealed only few significant differences. To prevent the development of retropatellar arthrosis, maximum contact areas are necessary. The study has shown an advantage for medially dominating muscle traction, and external rotation of the femur.  相似文献   

11.
The objective of this study was to validate the MRI-based joint contact modeling methodology in the radiocarpal joints by comparison of model results with invasive specimen-specific radiocarpal contact measurements from four cadaver experiments. We used a single validation criterion for multiple outcome measures to characterize the utility and overall validity of the modeling approach. For each experiment, a Pressurex film and a Tekscan sensor were sequentially placed into the radiocarpal joints during simulated grasp. Computer models were constructed based on MRI visualization of the cadaver specimens without load. Images were also acquired during the loaded configuration used with the direct experimental measurements. Geometric surface models of the radius, scaphoid and lunate (including cartilage) were constructed from the images acquired without the load. The carpal bone motions from the unloaded state to the loaded state were determined using a series of 3D image registrations. Cartilage thickness was assumed uniform at 1.0 mm with an effective compressive modulus of 4 MPa. Validation was based on experimental versus model contact area, contact force, average contact pressure and peak contact pressure for the radioscaphoid and radiolunate articulations. Contact area was also measured directly from images acquired under load and compared to the experimental and model data. Qualitatively, there was good correspondence between the MRI-based model data and experimental data, with consistent relative size, shape and location of radioscaphoid and radiolunate contact regions. Quantitative data from the model generally compared well with the experimental data for all specimens. Contact area from the MRI-based model was very similar to the contact area measured directly from the images. For all outcome measures except average and peak pressures, at least two specimen models met the validation criteria with respect to experimental measurements for both articulations. Only the model for one specimen met the validation criteria for average and peak pressure of both articulations; however the experimental measures for peak pressure also exhibited high variability. MRI-based modeling can reliably be used for evaluating the contact area and contact force with similar confidence as in currently available experimental techniques. Average contact pressure, and peak contact pressure were more variable from all measurement techniques, and these measures from MRI-based modeling should be used with some caution.  相似文献   

12.
The hamstring muscles have been recognized as an important element in compensating for the loss of stability in the ACL-deficient knee, but it is still not clear whether the hamstring muscle force can completely compensate for the loss of ACL, and the consequences of increased hamstring muscle force. A two-dimensional anatomical knee model in the sagittal plane was developed to examine the effect of various levels of hamstring muscle activation on restraining anterior tibial translation in the ACL-deficient knee during level walking. The model included the tibiofemoral and patellofemoral joints, four major ligaments, the medial capsule, and five muscle units surrounding the knee. Simulations were conducted to determine anterior tibial translation and internal joint loading at a single selected position when the knee was under a peak external flexion moment during early stance phase of gait. Incremental hamstring muscle forces were applied to the modeled normal and the ACL-deficient knees. Results of simulations showed that the ACL injury increased the anterior tibial translation by 11.8mm, while 56% of the maximal hamstring muscle force could reduce the anterior translation of the tibia to a normal level during the stance phase of gait. The consequences of increased hamstring muscle force included increased quadriceps muscle force and joint contact force.  相似文献   

13.
Fuji film has been widely used in studies aimed at obtaining the contact mechanics of articular joints. Once sealed for practical use in biological joints, Fuji Pressensor film has a total effective thickness of 0.30 mm, which is comparable to the cartilage thickness in the joints of many small animals. The average effective elastic modulus of Fuji film is approximately 100 MPa in compression, which is larger by a factor of 100-300 compared to that of normal articular cartilage. Therefore, inserting a Pressensor film into an articular joint will change the contact mechanics of the joint. The measurement precision of the Pressensor film has been determined systematically; however, the changes in contact mechanics associated with inserting the film into joints have not been investigated. This study was aimed at quantifying the changes in the contact mechanics associated with inserting sealed Fuji Pressensor film into joints. Spherical and cylindrical articular joint contact mechanics with and without Pressensor film and for varying degrees of surface congruency were analyzed and compared by using finite element models. The Pressensor film was taken as linearly elastic and the cartilage was assumed to be biphasic, composed of a linear elastic solid phase and an inviscid fluid phase. The present analyses showed that measurements of the joint contact pressures with Fuji Pressensor film will change the maximum true contact pressures by 10-26 percent depending on the loading, geometry of the joints, and the mechanical properties of cartilage. Considering this effect plus the measurement precision of the film (approximately 10 percent), the measured joint contact pressures in a joint may contain errors as large as 14-28 percent.  相似文献   

14.
Joint inflammation, with consequent cartilage damage and pain, typically reduces functionality and affects activities of daily life in a variety of musculoskeletal diseases. Since mechanical loading is an important determinant of the disease process, a possible conservative treatment is the unloading of joints. In principle, a neuromuscular rehabilitation program aimed to promote alternative muscle recruitments could reduce the loads on the lower-limb joints during walking. The extent of joint load reduction one could expect from this approach remains unknown. Furthermore, assuming significant reductions of the load on the affected joint can be achieved, it is unclear whether, and to what extent, the other joints will be overloaded. Using subject-specific musculoskeletal models of four different participants, we computed the muscle recruitment strategies that minimised the hip, knee and ankle contact force, and predicted the contact forces such strategies induced at the other joints. Significant reductions of the peak force and impulse at the knee and hip were obtained, while only a minimal effect was found at the ankle joint. Adversely, the peak force and the impulse in non-targeted joints increased when aiming to minimize the load in an adjacent joint. These results confirm the potential of alternative muscle recruitment strategies to reduce the loading at the knee and the hip, but not at the ankle. Therefore, neuromuscular rehabilitation can be targeted to reduce the loading at affected joints but must be considered carefully in patients with multiple joints affected due to the potential adverse effects in non-targeted joints.  相似文献   

15.
Modern computerized planning tools for periacetabular osteotomy (PAO) use either morphology-based or biomechanics-based methods. The latter relies on estimation of peak contact pressures and contact areas using either patient specific or constant thickness cartilage models. We performed a finite element analysis investigating the optimal reorientation of the acetabulum in PAO surgery based on simulated joint contact pressures and contact areas using patient specific cartilage model. Furthermore we investigated the influences of using patient specific cartilage model or constant thickness cartilage model on the biomechanical simulation results. Ten specimens with hip dysplasia were used in this study. Image data were available from CT arthrography studies. Bone models were reconstructed. Mesh models for the patient specific cartilage were defined and subsequently loaded under previously reported boundary and loading conditions. Peak contact pressures and contact areas were estimated in the original position. Afterwards we used a validated preoperative planning software to change the acetabular inclination by an increment of 5° and measured the lateral center edge angle (LCE) at each reorientation position. The position with the largest contact area and the lowest peak contact pressure was defined as the optimal position. In order to investigate the influence of using patient specific cartilage model or constant thickness cartilage model on the biomechanical simulation results, the same procedure was repeated with the same bone models but with a cartilage mesh of constant thickness. Comparison of the peak contact pressures and the contact areas between these two different cartilage models showed that good correlation between these two cartilage models for peak contact pressures (r = 0.634 ∈ [0.6, 0.8], p < 0.001) and contact areas (r = 0.872 > 0.8, p < 0.001). For both cartilage models, the largest contact areas and the lowest peak pressures were found at the same position. Our study is the first study comparing peak contact pressures and contact areas between patient specific and constant thickness cartilage models during PAO planning. Good correlation for these two models was detected. Computer assisted planning with FE modeling using constant thickness cartilage models might be a promising PAO planning tool when a conventional CT is available.  相似文献   

16.
The transmission of load through the human hip joint   总被引:8,自引:0,他引:8  
This paper describes the results of loading experiments carried out on human hip joints. The unloaded surfaces of the femoral head and the acetabulum are slightly incongruous. The location and magnitude of the contact areas between the surfaces therefore depend on the magnitude and direction of the applied load. The contact areas were determined experimentally for a variety of loads typical of normal walking. Two distinct contact areas were found on the anterior and posterior aspects of the acetabulum at light loads, gradually merging with increasing load until, at a certain transition load, the dome of the acetabulum comes into contact and contact is then complete. The value of the transition load depends on the rate of loading, due to creep of the cartilage, and was found to vary from 50 per cent of body weight in young specimens to 25 per cent of body weight for elderly specimens for rates of loading typical of normal walking. Thus, the dome of the acetabulum is out of contact for a substantial portion of the swing phase of normal walking.

The analysis of a much simplified model of the hip joint is presented. The dependence of contact area on load is demonstrated, but also a method of determining the transition load for complete contact from the load/deflection relation for the hip is suggested. The values of the transition load quoted above were obtained by this method. The analysis further indicates that the distribution of pressure between the articular surfaces depends critically on the distribution of cartilage thickness throughout the joint. It is suggested that the distribution of cartilage thickness is such as to lead to a state of uniform pressure at the upper end of the physiological load range. Some experimental evidence is presented in support of this suggestion.

It is concluded that the function of joint incongruity is to allow the articular surfaces to come out of contact at light loads so that the cartilage may be exposed to synovial fluid for the purposes of nutrition and lubrication. At large loads, the distribution of cartilage thickness ensures that a state of hydrostatic pressure is achieved in order that cartilage, with a large fluid content, may transmit large pressures without flow and consequent loss of its integrity.  相似文献   


17.
Experimental measurements in conjunction with theoretical predictions were used to determine the extent of load supported by the fluid phase of cartilage at the articular surface. The u-p finite element model was used to simulate the loading of six separate porcine knee joints and to predict surface deformations of the cartilage layer on the lateral femoral condyle. Representative geometry for the condyle, contact pressures, and intrinsic material properties of the cartilage layer were supplied from experimental measures (see Part I). The u-p finite element predictions for surface deformations of the cartilage layer were obtained for several load partitioning states between the solid and fluid phases of cartilage at the articular surface. These were then compared to actual surface deformations obtained experimentally. It appeared from the comparison that approximately 75 percent of the applied load was borne by the fluid phase at the articular surface under this loading regime. This was qualitatively in agreement with the hypothesis that an applied load to articular joints is partitioned at the surface to the two phases according to the surface area ratios of the solid and fluid phases. It appeared that the solid phase was shielded from the total applied stress on the articular surface by the fluid and could be a reason for the excellent durability of the tissue under the demanding conditions in a diarthrodial joint.  相似文献   

18.
Abnormal, excessive stresses acting on articular joint surfaces are speculated to be one of the causes for joint degeneration. However, articular surface stresses have not been studied systematically, since it is technically difficult to measure in vivo contact areas and pressures in dynamic situations. Therefore, we implemented a numerical model of articular surface contact using accurate surface geometries. The model was developed for the cat patellofemoral joint. We demonstrated that small misalignments of the patella relative to the femur change the joint contact mechanics substantially for a given external load. These results suggest that misalignment might be studied as one of the factors causing articular cartilage disorder and joint degeneration.  相似文献   

19.
An experimental technique for quantifying load-sharing in cadaveric spines is used to test the hypothesis that degenerative changes in human apophyseal joints are directly related to high levels of compressive load-bearing by these joints. About 36 cadaveric thoraco-lumbar motion segments aged 64-92 years were subjected to a compressive load of 1.5 kN. The distribution of compressive stress was measured in the intervertebral discs using a miniature pressure transducer, and stress measurements were summed over area to give the compressive force resisted by the disc. This was subtracted from the applied 1.5 kN to indicate compressive load-bearing by the apophyseal joints. The cartilage of each apophyseal joint surface was then graded for degree of degeneration. After maceration, each joint surface was scored for degenerative joint disease (DJD) affecting the bone. Results demonstrated that the apophyseal joints resisted 5-96% (mean 45%) of the applied compressive force. A significant positive correlation was demonstrated between age and cartilage degeneration, age and DJD bone score, apophyseal joint load-bearing and bone score, and cartilage score and load-bearing. The latter correlation was strongest for load-bearing above 50%. Ordinal regression showed that the variables describing bone DJD (marginal osteophytes, pitting, bony contour change, and eburnation) were significantly correlated with degree of cartilage degeneration. It is concluded that in elderly individuals apophyseal joint load-bearing above a threshold of 50% is associated with severe degenerative changes in cartilage and bone, and that markers of DJD observed palaeopathologically may be used as predictors of such loadingin life.  相似文献   

20.
Estimation of the hip joint contact area and pressure distribution during activities of daily living is important in predicting joint degeneration mechanism, prosthetic implant wear, providing biomechanical rationales for preoperative planning and postoperative rehabilitation. These biomechanical data were estimated utilizing a generic hip model, the Discrete Element Analysis technique, and the in vivo hip joint contact force data. The three-dimensional joint potential contact area was obtained from the anteroposterior radiograph of a subject and the actual joint contact area and pressure distribution in eight activities of daily living were calculated. During fast, normal, and slow walking, the peak pressure of moderate magnitude was located at the lateral roof of the acetabulum during mid-stance. In standing up and sitting down, and during knee bending, the peak pressures were located at the edge of the posterior horn and the magnitude of the peak pressure during sitting down was 2.8 times that of normal walking. The peak pressure was found at the lateral roof in climbing up stairs which was higher than that in going down stairs. These results can be used to rationalize rehabilitation protocols, functional restrictions after complex acetabular reconstructions, and prosthetic component wear and fatigue test set up. The same model and analysis can provide further insight to soft tissue loading and pathology such as labral injury. When the pressure distribution on the acetabulum is inverted onto the femoral head, prediction of subchondral bone collapse associated with avascular necrosis can be achieved with improved accuracy.  相似文献   