共查询到20条相似文献,搜索用时 9 毫秒
1.
Felodipine quantification in human plasma by high-performance liquid chromatography coupled to tandem mass spectrometry 总被引:2,自引:0,他引:2
Migliorança LH Barrientos-Astigarraga RE Schug BS Blume HH Pereira AS De Nucci G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,814(2):217-223
A rapid, sensitive, robust and specific method was developed for the determination and quantitation of felodipine, in human blood plasma by liquid chromatography coupled with tandem mass spectrometry using nimodipine as internal standard. Felodipine was extracted from 0.5 mL human plasma by use of a liquid/liquid procedure using diethyl ether/hexane (80/20, v/v) as eluent. The method included a chromatographic run of 5 min using a C(18) analytical column (100 mm x 4.6 mm i.d.) and the calibration curve was linear over the range from 0.02 to 10 ng mL(-1) (r(2) > 0.994). The between-run precision, determined as relative standard deviation of replicate quality controls, was 5.7% (0.06 ng mL(-1)), 7.1% (0.6 ng mL(-1)) and 6.8% (7.5 ng mL(-1)). The between-run accuracy was +/- 0.0, 2.1 and 3.1% for the above-mentioned concentrations, respectively. 相似文献
2.
Zhao M Rudek MA He P Hafner FT Radtke M Wright JJ Smith BD Messersmith WA Hidalgo M Baker SD 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,846(1-2):1-7
A rapid, sensitive and specific method was developed and validated using LC/MS/MS for determination of sorafenib in human plasma. Sample preparation involved a single protein precipitation step by the addition of 0.1 mL of plasma with 0.5 mL acetonitrile. Analysis of the compounds of interest including the internal standard ([(2)H(3)(15)N] sorafenib) was achieved on a Waters X-Terra C(18) (150 mm x 2.1mm i.d., 3.5 microm) analytical column using a mobile phase consisting of acetonitrile/10 mM ammonium acetate (65:35, v/v) containing 0.1% formic acid and isocratic flow at 0.2 mL/min for 6 min. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 7.3-7260 ng/mL for the human plasma samples with values for the coefficient of determination of >0.96. The values for both within day and between day precision and accuracy were well within the generally accepted criteria for analytical methods (<15%). 相似文献
3.
Damen CW Rosing H Tibben MM van Maanen MJ Lagas JS Schinkel AH Schellens JH Beijnen JH 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,868(1-2):102-109
A sensitive, specific and fast high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) assay for the determination of vinorelbine in mouse and human plasma is presented. A 200 microL aliquot was extracted with solid-phase extraction (SPE) using Bond-Elut C(2) cartridges. Dried extracts were reconstituted in 100 microL 1 mM ammonium acetate pH 10.5-acetonitrile-methanol (21:9:70, v/v/v) containing the internal standard vintriptol (100 ng/mL) and 10 microL volumes were injected onto the HPLC system. Separation was achieved on a 50 mm x 2.0 mm i.d. Gemini C(18) column using isocratic elution with 1 mM ammonium acetate pH 10.5-acetonitrile-methanol (21:9:70, v/v/v) at a flow rate of 0.4 mL/min. HPLC run time was only 5 min. Detection was performed using positive ion electrospray ionization followed by tandem mass spectrometry (ESI-MS/MS). The assay quantifies vinorelbine from 0.1 to 100 ng/mL using human plasma sample volumes of 200 microL. With this method vinorelbine can be measured in mouse plasma samples when these samples are diluted eight times in control human plasma. Calibration samples prepared in control human plasma can be used for the quantification of the drug. The lower limit of quantification in mouse plasma is 0.8 ng/mL. This assay is used to support preclinical and clinical pharmacologic studies with vinorelbine. 相似文献
4.
Qianyang Huang Xiang Zhou Danting Liu Baozhong Xin Karen Cechner Heng Wang Aimin Zhou 《Analytical biochemistry》2014
Gangliosides are a family of glycosphingolipids characterized by mono- or polysialic acid-containing oligosaccharides linked through 1,3- and 1,4-β glycosidic bonds with subtle differences in structure that are abundantly present in the central nervous systems of many living organisms. Their cellular surface expression and physiological malfunction are believed to be pathologically implicated in considerable neurological disorders, including Alzheimer and Parkinson diseases. Recently, studies have tentatively elucidated that mental retardation or physical stagnation deteriorates as the physiological profile of gangliosides becomes progressively and distinctively abnormal during the development of these typical neurodegenerative syndromes. In this work, a reverse-phase liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay using standard addition calibration for determination of GM2, GM3, GD2, and GD3 in human plasma has been developed and validated. The analytes and internal standard were extracted from human plasma using a simple protein precipitation procedure. Then the samples were analyzed by reverse-phase ultra-performance liquid chromatography (UPLC)/MS/MS interfaced to mass spectrometry with electrospray ionization using a multiple reaction monitoring mode to obtain superior sensitivity and specificity. This assay was validated for extraction recovery, calibration linearity, precision, and accuracy. Our quick and sensitive method can be applied to monitor ganglioside levels in plasma from normal people and neurodegenerative patients. 相似文献
5.
do C Borges NC Mendes GD Barrientos-Astigarraga RE Galvinas P Oliveira CH De Nucci G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,827(2):165-172
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection (LC-MS/MS) was developed for the determination of Verapamil in human plasma using Metoprolol as the internal standard. The analyte and internal standard were extracted from the plasma samples by liquid-liquid extraction and chromatographed on a C(8) analytical column. The mobile phase consisted of methanol-water (70:30; v/v)+12 mM formic acid. The method had a chromatographic total run time of 3.5 min and was linear within the range 1.00-500 ng/mL. Detection was carried out on a Micromass Quattro Ultima tandem mass spectrometer by multiple reaction monitoring (MRM). The intra-run imprecision was less than 5.1% calculated from the quality control (QC) samples, and 16.3% from the limit of quantification (LOQ). The accuracy determined from QC samples were between 92.9 and 103.1%, and 95.2 and 115.3% from LOQ. Concerning the inter-batch analysis, the imprecision was less than 5.8% and 17.3% from QC samples and LOQ, respectively. The accuracy varied between 98.2 and 100.8% from QC and it was 103.1% from LOQ. The protocol herein described was employed in a bioequivalence study of two tablet formulations of Verapamil. 相似文献
6.
Boulton DW Duncan GF Vachharajani NN 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2002,775(1):57-62
A sensitive and convenient high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) assay for the opioid receptor agonist-antagonist butorphanol in human plasma is described. BC-2605, a cyclopropyl analogue of butorphanol, was employed as an internal standard. Butorphanol was recovered from plasma (84.4 +/- 10.9%) by liquid-liquid extraction. The mobile phase flow-rate was 0.3 ml/min and consisted of methanol-water-formic acid (90:10:0.1, v/v/v). The analytical column (4.6 x 100 mm) was packed with Partisil C(8) (5 microm). The standard curve was linear from 13.7 to 1374 pg/ml (r(2)>0.99). The lower limit of quantitation was 13.7 pg/ml. The assay was specific, accurate (% deviation from nominal concentrations were <15%), precise and reproducible (within- and between-day coefficients of variation <7%). Butorphanol in plasma was stable over 3 freeze/thaw cycles and at room temperature for 1 day. The utility of the assay was demonstrated by following butorphanol plasma concentrations in two healthy subjects for 24 h following a 1 mg intranasal dose. 相似文献
7.
Sensitive liquid chromatography-mass spectrometry assay for quantitation of docetaxel and paclitaxel in human plasma 总被引:2,自引:0,他引:2
Parise RA Ramanathan RK Zamboni WC Egorin MJ 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,783(1):231-236
We have developed a high-performance liquid chromatography-electrospray ionization mass spectrometry (LC-MS) method for quantifying docetaxel and paclitaxel in human plasma. The assay fulfills the need for defining the lower plasma concentrations of these antineoplastic agents that result from a number of changes in how these agents are used clinically. The assay uses paclitaxel as the internal standard for docetaxel, and vice versa; solid-phase extraction; a Phenomenex Hypersil ODS (5 micrometer, 100x2 mm) reversed-phase analytical column; an isocratic mobile phase of 0.1% formic acid in methanol-water (70:30, v/v); and mass spectrometric detection using electrospray positive mode electron ionization. The assay has a lower limit of quantitation (LLOQ) of 0.3 nM and is linear between 0.3 nM and 1 microM for docetaxel. For paclitaxel, the LLOQ was 1 nM, and the assay is linear between 1 nM and 1 microM. We demonstrated the suitability of this assay for docetaxel by using it to quantify the docetaxel concentrations in plasma of a patient given 40 mg/m(2) of docetaxel and comparing those results to results produced when the same samples were assayed with an HPLC assay using absorbance detection. In a similar manner, the suitability of the assay for paclitaxel was demonstrated by using it to quantify the concentrations of paclitaxel in the plasma of a patient given 15 mg/m(2) of paclitaxel and comparing those results to results produced when the same samples were assayed with an HPLC assay using absorbance detection. The LC-MS assay, which proved superior because of its greater sensitivity and relatively short (7 min) run time, should be an important tool for future pharmacokinetic analyses of docetaxel and paclitaxel. 相似文献
8.
Li H Wang Y Jiang Y Tang Y Wang J Zhao L Gu J 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,852(1-2):436-442
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for simultaneous quantification of valsartan and hydrochlorothiazide in human plasma. After a simple protein precipitation using acetonitrile, the analytes were separated on a Zorbax SB-Aq C18 column using acetonitrile-10mM ammonium acetate (60:40, v/v, pH 4.5) as mobile phase at a flow rate of 1.2 mL/min. Valsartan and hydrochlorothiazide were eluted at 2.08 min and 1.50 min, respectively, ionized using ESI source, and then detected by multiple reaction monitoring (MRM) mode. The precursor to product ion transitions of m/z 434.2-350.2 and m/z 295.9-268.9 were used to quantify valsartan and hydrochlorothiazide, respectively. The method was linear in the concentration range of 4-3600 ng/mL for valsartan and 1-900 ng/mL for hydrochlorothiazide. The method was successfully employed in a pharmacokinetic study after an oral administration of a dispersible tablet containing 80 mg valsartan and 12.5 mg hydrochlorothiazide to each of the 20 healthy volunteers. 相似文献
9.
High-performance liquid chromatography coupled with negative ion tandem mass spectrometry for determination of pravastatin in human plasma 总被引:1,自引:0,他引:1
Zhu Z Neirinck L 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,783(1):133-140
A new method, using high-performance liquid chromatography/ion electrospray (negative ion) mass spectrometry, has been developed for the determination of a hydrophilic liver-specific inhibitor of the enzyme 3-hydroxy-3-methylglutaryl coenzyme A reductase, pravastatin in human plasma. In this method, plasma samples were prepared by a solid-phase extraction on C(18) Bond Elut cartridge. Chromatography was carried out with a Zorbax C(8) column. Simple isocratic chromatography conditions were used. The method has been validated in a linear range of 0.25-300 ng/ml with a coefficient of variation of 0.6-3.4%. The overall recovery was 90.5% for pravastatin and 90.8% for the internal standard beta-hydroxy-lovastatin. The method is simple and reliable with a total run time of less than 2 min. 相似文献
10.
Jain L Gardner ER Venitz J Giaccone G Houk BE Figg WD 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(30):3187-3192
A simple, rapid and sensitive liquid chromatography/tandem mass spectrometric (LC/MS/MS) analytical method was developed for quantification of Hsp90 inhibitor PF-04928473 in human plasma, following administration of its prodrug, PF-04929113. Sample processing involved protein precipitation by addition of 0.4 mL of methanol containing internal standard (PF-04972487) to 50 μL volume of plasma sample. Chromatographic separation of PF-04928473 and PF-04972487 was achieved on a Phenomenex® Luna C18(2) (2.0mm × 50 mm, 5 μm) column using a gradient elution method with mobile phase solvents: methanol containing 0.1% formic acid and 0.1% formic acid at a flow rate of 0.25 mL/min. Detection was performed in electrospray positive ionization mode, monitoring the ion transitions from m/z 465.1 → 350.1 (PF-04928473) and m/z 447.0 → 329.1 (PF-04972487). The retention times for PF-04928473 and PF-04972487 were 1.86 and 2.85 min, respectively. Calibration curves were generated in the range of 2–2000 ng/mL. The accuracy and precision ranged from 94.1 to 99.0% and 86.7 to 97.6%, respectively, which were calculated using quality control samples of three different concentrations analyzed in quintuplicate on four different days. 相似文献
11.
Mendes GD Hamamoto D Ilha J Pereira Ados S De Nucci G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,850(1-2):553-559
A rapid, sensitive and specific method for quantifying the aromatase inhibitor (anastrozole) in human plasma using dexchlorpheniramine as the internal standard (I.S.) is described herein. The analyte and the I.S. were extracted from 200 microl of human plasma by liquid-liquid extraction using a mixture of diethyl ether:dichloromethane (70:30, v/v) solution. Extracts were removed and dried in the organic phase then reconstituted with 200 microl of acetonitrile:water (50:50; v/v). The extracts were analyzed by high performance liquid chromatography coupled with photospray tandem mass spectrometry (HPLC-MS-MS). Chromatography was performed isocratically on a Genesis, C18 4 microm analytical column (100 mm x 2.1mm i.d.). The method had a chromatographic run time of 2.5 min and a linear calibration curve ranging from 0.05-10 ng ml(-1). The limit of quantification (LOQ) was 0.05 ng ml(-1). This HPLC-MS-MS procedure was used to assess pharmacokinetic studies. 相似文献
12.
Mostafa A Medley G Roberts DM Mohamed MS Elshanawani AA Roberts MS Liu X 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(23):2234-2238
Carbofuran (CFN), carbosulfan (CSN) and fenobucarb (FBC) are carbamate pesticides that are widely used in gardening and agriculture for the control of insects. Human poisoning due to occupational or self-poisoning exposures is also reported, so assays are required to quantify the plasma concentration of these insecticides. An LC-MS/MS method was developed and validated for the simultaneous quantification of these three carbamate insecticides in the plasma of patients with acute intentional self-poisoning. Plasma samples were pretreated by acetonitrile for protein precipitation. Chromatography was carried out on a Luna C18(2) analytical column with gradient elution using a mobile phase containing acetonitrile and water with 10mM ammonium acetate. Mass spectrometric analysis was performed by an Applied Biosystems MDS Sciex API 2000 triple quadrupole mass spectrometer coupled with electrospray ionization (ESI) source in the positive ion mode. The total run time was 7 min. The assay was validated over a concentration range from 10 to 1000 ng/ml for CSN and FBC and 20-2000 ng/ml for CFN. The precision and accuracy for both intra- and inter-day determination of all analytes were acceptable (<15%). No significant matrix effect was observed. Stability of compounds was established for short term bench and autosampler storage as well as freeze/thaw cycles. The method was effectively applied to 270 clinical samples from patients with a history of acute intentional carbamate self-poisoning. 相似文献
13.
Kuijsten A Buijsman MN Arts IC Mulder PP Hollman PC 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,822(1-2):178-184
Enterolactone and enterodiol are phytoestrogens with structural similarity to endogenous estrogens. Because of their biological activities, they may affect the development of several diseases. To quantify enterodiol and enterolactone in plasma, we developed and validated a liquid chromatography-tandem mass spectrometry method with electrospray ionization using 13C3 labeled isotopes. The method consists of a simple enzymatic hydrolysis and ether extraction followed by a rapid LC separation (run-time of 11 min). Detection limits as low as 0.15 nM for enterodiol and 0.55 nM for enterolactone were achieved. The within-run R.S.D. ranges from 3 to 6% and the between-run R.S.D. ranges from 10 to 14% for both enterolignans. This method allows simple, rapid, and sensitive quantification, and is suitable for measuring large numbers of samples. 相似文献
14.
Frerichs VA Zaranek C Haas CE 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,824(1-2):71-80
A method has been developed and validated for the quantitation of midazolam, alphahydroxy-midazolam, omeprazole, and hydroxyomeprazole from one 250 microL sample of human plasma using high performance liquid chromatography coupled to tandem mass spectrometry. The method was validated for a daily working range of 0.400-100 ng/mL, with limits of detection between 2 and 15 pg/mL. The inter-assay variation was less than 15% for all analytes at four control concentrations and the samples were stable for three freeze-thaw cycles under the analysis conditions and 24 h in the post-preparative analysis matrix. This method was used to analyze samples in support of clinical studies probing the activity of the cytochrome P-450 enzyme system. 相似文献
15.
Li L Meng F Guo J Sun L Yu N Zhao Y 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(15-16):1033-1037
We developed and validated a quantitative method for simultaneously determining the concentrations of tracheloside and trachelogenin in rat plasma. Plasma samples were prepared by liquid-liquid extraction with ethyl acetate. Isocratic chromatographic separation was performed on a reversed-phase Diamonsil C(18) column (4.6×200 mm, 5 μm). The mobile phase consisted of methanol and 10mM aqueous ammonium formate (80:20, v/v). Analyte detection was achieved by positive electrospray ionization (ESI) tandem mass spectrometry. Calibration was performed by internal standardization with glipizide, and regression curves ranging from 0.625 to 625 ng/mL were constructed for both the analytes. The intra- and inter-day precision values were below 8%, and accuracy ranged from -5.33% to 2.53% in all quality control samples. In this study, the validated method was successfully applied to determine the pharmacokinetic profile of tracheloside and trachelogenin in rat plasma after oral and intravenous administration of trachelospermi total lignans. 相似文献
16.
Tang C 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(31):3317-3322
A sensitive, simple and feasible method has been developed and validated for the simultaneous determination of three diastereoisomers of hexabromocyclododecane (HBCD) in human plasma using liquid chromatography tandem mass spectrometry (LC-MS/MS). The simple pretreatment generally involved protein precipitation with methanol (MeOH). The separation was performed with a C18 reverse phase column. The mobile phases were 5mM ammonium acetate (NH(4)AC) in water and acetonitrile (ACN). The mass spectrometer was operated using negative electrospray ionization (ESI) source and the data acquisition was carried out with multiple reaction monitoring (MRM) mode. The analyte quantifications were performed by external standard method with matrix-matched calibration curves. The method was partially validated with the evaluations of accuracy, precision, linearity, limit of quantification (LOQ), limit of detection (LOD), recovery, matrix effect and carryover effect. With the present method, the intra-batch accuracies were 94.7-104.3%, 91.9-109.3% and 89.8-105.0% for α-, β- and γ-HBCD, respectively. And the inter-batch accuracies were ranged from 94.2% to 109.7%. Both intra-batch and inter-batch precisions (relative standard deviation, RSD, %) of the analytes were no more than 11.2%. The recoveries were from 79.0% to 108.9% and the LOQ was 10pg/mL for each diastereoisomer. The linear range was 10-10,000pg/mL with the linear correlation coefficient R(2)>0.996. No significant matrix effect and carryover effect of the analytes were observed in this study. This method is in possession of sufficient resolution, high sensitivity as well as selectivity and convenient to be applied to the trace determination of HBCDs in human plasma. 相似文献
17.
Lisinopril quantification in human plasma by liquid chromatography-electrospray tandem mass spectrometry 总被引:4,自引:0,他引:4
Padua AA Barrientos-Astigarraga RE Rezende VM Mendes GD De Nucci G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,809(2):211-216
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection was developed for the determination of Lisinopril in human plasma using Enalaprilat as internal standard. The analyte and internal standard were extracted from the plasma samples by solid-phase extraction using Waters HLB Oasis SPE cartridges and chromatographed on a C8 analytical column. The mobile phase consisted of acetonitrile/water (60:40, v/v) + 20 mM acetic acid + 4.3 mM of triethylamine. The method had a chromatographic total run-time of 6.5 min and was linear within the range 2.00-200 ng/ml. Detection was carried out on a Micromass triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM). The precision (CV%) and accuracy, calculated from limit of quantification (LOQ) samples (n = 8), were 8.9 and 98.9%, respectively. The method herein described was employed in a bioequivalence study of two tablet formulations of Lisinopril 20mg. 相似文献
18.
Enantiomeric determination of amlodipine in human plasma by liquid chromatography coupled to tandem mass spectrometry 总被引:3,自引:0,他引:3
Streel B Lainé C Zimmer C Sibenaler R Ceccato A 《Journal of biochemical and biophysical methods》2002,54(1-3):357-368
A sensitive method for the separation and determination of amlodipine enantiomers in plasma has been developed based on solid-phase extraction (SPE) with disposable extraction cartridges (DECs) in combination with chiral liquid chromatography (LC). The SPE technique is used to isolate the drug from the biological matrix and to prepare a cleaner sample before injection and analysis by HPLC coupled to mass spectrometry. The DEC is filled with ethyl silica (50 mg) and is first conditioned with a 2.5% ammonia in methanol solution and then with ammonium acetate buffer. A 1.0-ml volume of plasma is then applied on the DEC. The washing step is first performed with ammonium acetate buffer and secondly with a mixture of water and methanol (65:35, v/v), while the final elution step is obtained by dispensing methanol containing 2.5% of ammonia. The eluate is then collected and evaporated to dryness before being dissolved in the LC mobile phase and injected into the LC system. The stereoselective analysis of amlodipine is achieved on a Chiral AGP column containing alpha(1)-acid glycoprotein as chiral selector by using a mobile phase consisting of a 10-mM acetate buffer (pH 4.5) and 1-propanol (99:1, v/v). The LC system is coupled to tandem mass spectrometry with an APCI interface in the positive-ion mode. The chromatographed analytes are detected in the selected reaction monitoring mode (SRM). The MS/MS ion transitions monitored are 409 to 238 for amlodipine, and 260 to 116 for S-(-)-propranolol used as internal standard (IS). The method was validated considering different parameters, such as linearity, precision and accuracy. The limit of quantitation was found to be 0.1 ng/ml for each amlodipine enantiomer. 相似文献
19.
Emily Lipsitz Ganesh Moorthy Yael Mosse Elizabeth Fox Peter C. Adamson 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(25):2369-2373
We describe a selective and a highly sensitive high-performance liquid chromatography–electron spray ionization-collision induced dissociation-tandem mass spectrometry (HPLC–ESI-CID-MS/MS) assay for the Aurora A kinase inhibitor MLN8237 in human plasma. The intra-day precision based on the standard deviation of replicates of quality control samples ranged from 0.2 to 4% and with accuracy ranging from 96 to 102%. The inter-day precision ranged from 0.5 to 7% and the accuracy ranged from 93 to 105%. Stability studies showed that MLN8237 was stable both during the expected conditions for sample preparation and storage. The lower limit of quantification for MLN8237 was 5 ng/mL. The analytical method showed excellent sensitivity, precision, and accuracy. This method is robust and is being successfully employed in a Children's Oncology Group Phase 1 Consortium study of MLN8237 in children with cancer. 相似文献
20.
Lansoprazole quantification in human plasma by liquid chromatography-electrospray tandem mass spectrometry 总被引:3,自引:0,他引:3
Oliveira CH Barrientos-Astigarraga RE Abib E Mendes GD da Silva DR de Nucci G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,783(2):453-459
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection was developed for the determination of lansoprazole in human plasma using omeprazole as the internal standard. The analyte and internal standard were extracted from the plasma samples by liquid-liquid extraction using diethyl-ether-dichloromethane (70:30; v/v) and chromatographed on a C(18) analytical column. The mobile phase consisted of acetonitrile-water (90:10; v/v)+10 mM formic acid. The method has a chromatographic total run time of 5 min and was linear within the range 2.5-2000 ng/ml. Detection was carried out on a Micromass triple quadrupole tandem mass spectrometer by Multiple Reaction Monitoring (MRM). The intra- and inter-run precision, calculated from quality control (QC) samples, was less than 3.4%. The accuracy as determined from QC samples was less than 9%. The method herein described was employed in a bioequivalence study of two capsule formulations of lansoprazole. 相似文献