首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A confirmatory method coupling liquid chromatography with tandem mass spectrometry (LC/MS/MS) was developed to determine the concentration of oxytetracycline (OTC), tetracycline (TC), chlortetracycline (CTC) and doxycycline (DC), which make up the tetracycline (TC) groups present in royal jelly. Sample preparation included deproteination, control of pH, extraction and clean-up on a solid-phase extraction (SPE) cartridge. The analyses were achieved by LC/MS/MS in selected reaction monitoring mode (SRM). The overall recovery of fortified royal jelly at the levels of 5.0, 10.0 and 40.0 microg/kg ranged from 62% to 115%, and the coefficients of variation ranged from 3.4% to 16.3% (n=6). The detection limits for TCs were under 1.0 microg/kg. The transformation between the TCs and its epimers (EpiTCs) was studied in standard solution and during the sample preparation process. This method can be used for the detection of tetracycline residues in royal jelly.  相似文献   

2.
A novel CL method for the determination of tannic acid (TA) was established based on TA inhibition of the chemiluminescence (CL) emission of the luminol-hydrogen peroxide CL system catalysed by tetrasulphonated manganese phthalocyanine (MnTSPc) under alkaline conditions. The peak height is proportional to the natural logarithm of concentration of TA in the range 1.0 x 10(-7)-3.0 x 10(-10) mol/L with a detection limit of 5.6 x 10(-11) mol/L and the relative standard deviation was 2.5% for the determination of 1.0 x 10(-8) mol/L TA (n = 11). The proposed method has been successfully applied to the determination of TA in Chinese gall and industrial wastewater.  相似文献   

3.
A Waseem  M Yaqoob  A Nabi 《Luminescence》2004,19(6):333-338
A simple and rapid fl ow injection method is reported for the determination of iron in blood serum after acid digestion with HNO3 and HClO4, based on luminol CL detection in the absence of added oxidant. The detection limit (3 s) was 1.0 nmol/L with a sample throughput of 120/h. The calibration graph was linear over the range 0.001-1.0 micromol/L (r2 = 0.9974), with relative standard deviations (RSD) (n = 4) in the range 3.2-5%. The effect of interfering cations (Ca(II), Mg(II), Cu(II), Cd(II), Pb(II), Mn(II), Zn(II), Ni(II), Co(II) and Fe(III)) and anions (Cl-, SO4(2-), HCO3-, NO3-, NO2-) were studied using a luminol CL system for Fe(II) determination. The method was applied to normal blood serum and the results (1.32 +/- 0.08-1.74 +/- 0.05 mg/L) were compared with those from a spectrophotometric reference method (1.34 +/- 0.06-1.80 +/- 0.10 mg/L), which agree fairly well with the overall reference range in blood.  相似文献   

4.
Tetracyclines (TCs) were found to strongly inhibit the electrochemiluminescence (ECL) from the Ru(bpy)3(2+)-tripropylamine system when a working Pt electrode was maintained at 1.05 V (vs. Ag/AgCl) in pH 8.0 carbonate buffer solution. On this basis, a flow injection (FI) procedure with inhibited electrochemiluminescence detection has been developed for the determination of tetracycline (TC) and oxytetracycline (OTC). Under the optimized condition, the linear ranges of 2.0 x 10(-8)-1.0 x 10(-5) and 1.0 x 10(-8)-1.0 x 10(-5) g/mL and the detection limits of 4.0 x 10(-9) and 3.8 x 10(-9) g/mL were obtained for TC and OTC, respectively. The relative standard deviations (RSD) were 0.68% and 1.18% for 5.0 x 10(-7) g/mL TC and OTC (n = 13), respectively. The method showed higher sensitivity than most of the reported methods. It was successfully applied to the determination of tetracycline in a Chinese proprietary medicine, Tetracyclini and Cortisone Eye Ointment, and the residues of tetracycline in honey products. The inhibition mechanism has been proposed due to an energy transfer between electrogenerated Ru(bpy)3(2+)* and benzoquinone derivatives at the electrode surface.  相似文献   

5.
A rapid and accurate determination of tetracycline antibiotics in human serum by reversed-phase high-performance liquid chromatography with fluorescence detection has been developed, based on protein precipitation in serum. Various reagents for precipitation were investigated, and 24% trichloroacetic acid in methanolic solution gave the maximum recovery (at least 94.3%) and interference-free chromatograms of different three tetracyclines. At a concentration of 0.5 μg/ml, the precision (relative standard deviation) ranged from 1.12 to 1.94%. In the range 0.04–10.0 μg/ml for oxytetracycline and chlorotetracycline and 0.01–10.0 μg/ml for tetracycline, linear responses were observed. The detection limits of this method were 10–35 ng/ml for all three antibiotics. The proposed method was applied to the determination of serum concentrations in subjects receiving tetracycline antibiotics.  相似文献   

6.
A simple, rapid and sensitive method for the determination of ofloxacin in plasma has been developed based on flow-injection analysis with enhanced chemiluminescence (CL) detection. This method employs the CL reaction of cerium(IV) and sulphite sensitized by a Tb(III)-ofloxacin complex. Plasma samples were deproteinized with acetonitrile before analysis. Under optimal conditions, the method allowed the quantitative analysis of ofloxacin in plasma over the range of 22.5-900 ng/mL with a detection limit of 7.5 ng/mL (3sigma). The intra-day and inter-day precision was < 3.0% (n = 11) and < 7.0% (n = 3), respectively. The method was a convenient tool, rapid (20 s/analysis) and well suited for pharmacokinetics studies in which thousands of samples must be analysed daily. It was applied to pharmacokinetics studies of ofloxacin.  相似文献   

7.
To determine if there are inter-relationships between progesterone, oxytocin (OT), dopamine (DA), noradrenaline (NA) and ascorbic acid, these compounds were measured in the corpus luteum (CL) from cattle at different stages of the oestrous cycle (n = 42) and from 1-5 months of pregnancy (n = 27). They were measured by radioimmunoassay (RIA), high performance liquid chromatography (HPLC) and colorimetric methods. Corpora lutea were collected from heifers and cows within 30 min of slaughter on days 1-5, 6-10, 11-16 and 17-21 of the oestrous cycle. The stage of pregnancy was determined on the basis of foetal size and development. Each CL was divided into four parts and stored in liquid nitrogen. For hormone estimation, the tissue was homogenised/powdered and suspended in phosphate buffer (for OT and progesterone), 0.1 M trichloracetic acid (TCA; for catecholamines) or in ice-cold metaphosphoric acid (for ascorbic acid). There were no significant differences in the measured parameters between cows and heifers, and so the data were combined. The concentration of DA was correlated with NA (r = 0.66; P < 0.001) during the oestrous cycle and was highest in newly formed CL (P < 0.01) as compared with early CL, regressed CL and CL of pregnant females. NA was negatively correlated (P < 0.01) with progesterone (r = -0.53) and OT (r = -0.41). In contrast, progesterone and OT were positively correlated with each other (r = 0.81; P < 0.01) during all stages of the oestrous cycle, but not during pregnancy. The lowest concentrations of ascorbic acid were observed in regressed CL. Ascorbic acid concentrations were correlated (P < 0.01) with those of progesterone (r = 0.68), OT (r = 0.42) and DA (r = -0.37). Luteal concentrations of ascorbic acid, progesterone and OT followed a pattern consistent with the development and regression of the CL. Luteal concentrations of catecholamines were not consistent with this pattern.  相似文献   

8.
A new method using chemiluminescence (CL) detection has been developed for the simple determination of ketotifen fumarate (KF). The method is based on the catalytic effect of KF in the CL reaction of tris(1,10 phenanthroline)ruthenium(II), Ru(phen)32+, with Ce(IV) in sulfuric acid medium. The CL response was detected using a lab‐made chemiluminometer. Effects of chemical variables were investigated and under optimum conditions, the CL intensity was proportional to the concentration of the drug over the range 0.34‐34.00 µg mL?1 KF. The limit of detection (S/N=3) was 0.09 µg mL?1. Effects of common ingredients were investigated and the method was applied successfully for determining KF in pharmaceutical formulations and human plasma. The percent of relative standard deviation (n=11) at level of 3.4 µg mL?1 of KF was 4.6% and the minimum sampling rate was 70 samples per hour. The possible CL mechanism is proposed based on the kinetic characteristic of the CL reaction, CL spectrum, UV‐Vis and phosphorescence spectra. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

9.
A novel mixing approach was utilized with a highly sensitive chemiluminescence (CL) method to determine the total phenolic content (TPC) in honey samples using an acidic potassium permanganate–formaldehyde system. The mixing approach was based on exploiting the mixing efficiency of nanodroplets generated in a microfluidic platform. Careful optimization of the instrument setup and various experimental conditions were employed to obtain excellent sensitivity. The mixing efficiency of the droplets was compared with the CL signal intensity obtained using the common serpentine chip design, with both approaches using at a total flow rate of 15 μl min?1; the results showed that the nanodroplets provided 600% higher CL signal intensity at this low flow rate. Using the optimum conditions, calibration equations, limits of detection (LOD) and limits of quantification (LOQ) for gallic acid (GA), caffeic acid (CA), kaempferol (KAM), quercetin (QRC) and catechin (CAT) were obtained. The LOD ranged from 6.2 ppb for CA to 11.0 ppb for QRC. Finally, the method was applied for the determination of TPC in several local and commercial honey samples.  相似文献   

10.
A multiresidue method for the simultaneous determination of 22 organochlorine (OCs) and organophosphorus (Ops) pesticides (including isomers and metabolites), representing a wide range of physicochemical properties, was developed in fatty matrices extracted from meat. Pesticides were extracted from samples with acetonitrile/n-hexane (v:v, 1:1). The analytical screening was performed by gas chromatography coupled with electron-capture detection (ECD). The identification of compounds was based on their retention time and on comparison of the primary and secondary ions. The optimized method was validated by determining accuracy (recovery percentages), precision (repeatability and reproducibility), and sensitivity (detection and quantitation limits) from analyses of samples fortified at 38 to 300 ng/g levels. Correlation coefficients for the 22 extracted pesticide standard curves (linear regression analysis, n = 3) ranged from 0.998 to 1.000. Recovery studies from 2 g samples fortified at 3 levels demonstrated that the GC-ECD method provides 64.4-96.0% recovery for all pesticides except 2,4'-DDE (44.6-50.4%), 4,4'-DDE (51.1-57.5%) and 2,4'-DDT (50.0-51.2%). Both repeatability and reproducibility relative standard deviation values were < 20% for all residues. Detection limits ranged from 0.31 to 1.27 ng/g and quantification limits were between 1.04 and 4.25 ng/g. The proposed analytical method may be used as a simple procedure in routine determinations of OCs and Ops in meat. It can also be applied to the determination of pesticide multi-residues in other animal products such as butter and milk.  相似文献   

11.
A new chemiluminescence (CL) method is described for the determination of synephrine. It is based on the reaction between synephrine and Ce(IV) in a nitric acid medium and measurement of the CL intensity produced by rhodamine B used as a luminophore, similar to luminol or lucigenin in basic media, instead of as a sensitizer. In the optimum conditions, the increase of CL intensity was correlated with synephrine concentration over the range 5.0 x 10(-9)-1.0 x 10(-6) g/mL with a detection limit of 1.0 x 10(-9) g/mL. The relative standard deviation (RSD) was 2.9% for 1.0 x 10(-7) g/mL synephrine (n = 11). The method was applied to the determination of a drug in herbal products, citrus fruit and biological samples, with satisfactory results. The results given by the proposed method are in good agreement with those given by HPLC-UV and UV spectrophotometry.  相似文献   

12.
The development of a black market of chemical cocktails for illegal growth promotion in food-producing animals includes substances that are potentially dangerous for human health, such as synthetic corticosteroids. The potential presence of these residues in food makes it necessary to develop rapid and sensitive analytical methodologies to detect such substances, preferably in live animals before they arrive at the market. A chemiluminescence (CL) detection method for the determination of four synthetic corticosteroids (prednisolone, betamethasone, dexamethasone and flumethasone) in bovine urine has been developed. The proposed system, which does not need any derivatization procedure, offers an easy method well suited for routine research. Urine samples were homogenized with methanol:water (50:50, v/v) and centrifuged. The upper layer was collected and Strata X cartridges were used for cleaning up. The purified residues were evaporated to dryness and then redissolved in the mobile phase. Analysis of the extracts was performed using high-performance liquid chromatography with chemiluminescence detection, employing luminol as the CL reagent. The recovery curves, obtained at four spiking levels (different for each corticosteroid), showed that recoveries of at least 70% could be obtained for urine. The chemiluminescence detection procedure afforded satisfactory results with respect to sensitivity and the LOD and LOQ, taken as the first point of the regression curve, ranged from 4 ppb to 65 ppb. The maximum mean RSD was below 13% and below 15% for intra- and inter-day assay, respectively, in all cases.  相似文献   

13.
Yinhuan Li  Jiuru Lu 《Luminescence》2007,22(4):326-330
A simple, rapid, flow-injection chemiluminescence (CL) method is described for the determination of ibuprofen. A strong CL signal was detected when a mixture of the analyte and sulphite was injected into acidic KMnO(4). The CL signal is proportional to the concentration of ibuprofen in the range 0.1-10.0 mg/L. The detection limit is 0.02 mg/L ibuprofen, the relative standard deviation is 1.8% (0.5 mg/L ibuprofen; n = 11) and the sample measurement frequency is 120/h. The proposed method was successfully applied to the determination of ibuprofen in pharmaceutical preparations and in spiked urine samples. The mechanism of the CL reaction is also discussed.  相似文献   

14.
A validated high-performance liquid chromatography method is described for the determination of scutellarin in rat plasma using a liquid-liquid extraction and ultraviolet (UV) absorbance detection. The separation used a Diamonsil ODS column (250 mm x 4.6mm i.d., 5 microm particle size) with an isocratic mobile phase consisting of methanol-acetonitrile-50mM dihydrogen ammonium phosphate buffer (22:15:63 (v/v/v), adjusted to pH 2.5 with 1M phosphoric acid). The ultraviolet detector operated at 335 nm. Plasma samples were extracted with ethyl acetate after acidification. The extraction recovery of scutellarin ranged from 68.1 to 80.5%. High selectivity and a low quantitation limit (0.050 microg/ml) were achieved. The linear range was 0.050-12.5 microg/ml, correlation coefficient r=0.9981. The method has a good reproducibility, R.S.D. values were below 7.9% for within-day and between-day precision. The method is simple, rapid, and applicable to preliminary pharmacokinetic studies of scutellarin in rats.  相似文献   

15.
A method was developed for the determination of the seven nitroimidazoles including metronidazole (MNZ), ronidazole (RNZ), dimetridazole (DMZ), tinidazole (TNZ), ornidazole (ONZ), secnidazole (SNZ) and the common metabolite of RNZ and hydroxydimetridazole (DMOHZ) in poultry and pork muscles by high-performance liquid chromatography (HPLC) with ultraviolet detection (UV). After extraction with ethyl acetate and evaporation, the nitroimidazoles were redissolved in ethyl acetate and purified using strong cation exchange (SCX) solid-phase extraction (SPE) column. The HPLC separation was carried through on a C(18) bonded silica column with a deionized water-methanol-acetonitrile mobile phase using a gradient elution procedure. The limit of detection of all the seven nitroimidazoles was 0.2 microg/kg. The recoveries of the seven nitroimidazoles for chicken, pork and bacon samples spiked with 1-20 microg/kg were in the range of 71.4-99.5%. The linearity is satisfactory with a correlation coefficient of >0.998 at concentrations ranging from 0.7 to 60 microg/kg. The relative standard deviations of 10 measurements for spiked chicken, pork and bacon samples at the concentration of 1 and 20 microg/kg were in the range of 6.2-13.9% and 4.0-8.7%, respectively. The intra-day precision (n=5) for nitroimidazoles residues in chicken spiked at 20 microg/kg is 6.9%, and the inter-day precision for 5 days (n=25) is 11%. The method is capable of identifying nitroimidazole residues at > or =0.7 microg/kg levels and was applied in the determination of nitroimidazole residues in meat sample.  相似文献   

16.
A flow-injection method is described for the determination of carbaryl and carbofuran. It was found that a strong chemiluminescence (CL) signal was generated when these pesticides were mixed with Na(2)SO(3) and KMnO(4) in acidic medium. Under the optimum experimental conditions, the enhanced CL intensity was linear, with the concentrations in the range 0.1-2.0 microg/mL (r(2) = 0.9996 and 0.9993, n = 6) with relative standard deviation (n = 4) in the range 1.0-2.3%. The limits of detection (3sigma blank) were 10 and 50 ng/mL, respectively, with a sample throughput of 180/h. The proposed method was applied to determine carbaryl and carbofuran in freshwaters with satisfactory results. Most metal and non-metal ions and some pesticides, such as carbophenothion and aldicarb, do not interfere with the determination. Dinoseb, diazinon and malathion calibration graphs (in the range 0.2-2.0 microg/mL, r(2) = 0.9966-0.9988, n = 6) were also established with relative standard deviations (n = 4) in the range 1.2-2.0% with limits of detection (3sigma blank) in the range 100-300 ng/mL.  相似文献   

17.
A simple chemiluminescence (CL) method using flow injection has been developed for the determination of clindamycin, based on the inhibitory effect of clindamycin on the CL generated from the luminol-K(3)Fe(CN)(6) system in alkaline medium. It was found that the decrement of CL intensity was linear with the logarithm of clindamycin concentration over the range 0.7-1000 ng/mL. The detection limit was 0.2 ng/mL with a relative standard deviation (RSD) of <5.0% (n = 7). At a flow rate of 3.0 mL/min, a complete analytical process could be performed within 0.5 min, including sampling and washing. The proposed procedure was applied successfully to the determination of clindamycin in pharmaceutical preparations and human urine without pretreatment.  相似文献   

18.
A sensitive method for the determination of CQP propionic acid in rat plasma was developed and validated after solid-phase extraction. Chromatographic separation was achieved on a reversed-phase Alltima C18 column with the mobile phase of methanol-0.15% (v/v) phosphoric acid solution (pH 2.5) and step gradient elution resulted in a total run time of about 20min. The analytes were detected by using UV detector at 345nm. A good linear relationship was obtained in the concentration range of 50-12,800ng/mL (r=0.9998). The intra-day RSDs and the inter-day RSDs at the concentration of 200, 800, 6400 and 12,800ng/mL were less than 7.0% and 11.0%, respectively. The intra-day accuracy ranged from 96.3 to 106.5% and the inter-day accuracy ranged from 98.6 to 113.4%, respectively. Average extraction recoveries ranged from 83.6 to 94.3% in plasma at the concentrations of 200, 800, 6400 and 12,800ng/mL. This method was successfully applied to the pharmacokinetic studies on rats.  相似文献   

19.
A novel flow-injection chemiluminescence (CL) method for the determination of guanine was developed. The procedure is based on the CL reaction of guanine with hydrogen peroxide in borax buffer (pH 8.5) with Co2+ as a catalyst. The calibration graph is linear within the range of 3 x 10(-7)-9 x 10(-5) g/mL. A detection limit of 1 x 10(-7) g/mL, along with a relative standard deviation of 2.23% (3 x 10(-7) g/mL guanine, n = 11), were obtained. The present procedure was applied to the measurement of guanine in urine with recoveries of 97.5-107.5%. A possible CL mechanism of the reaction system is proposed.  相似文献   

20.
In this paper, a novel chemiluminescent (CL) method for the determination of benzhexol has been developed by combining the flow injection technique and its sensitizing effect on the weak CL reaction between sulfite and acidic cerium(IV). A mechanism for the CL reaction has been proposed on the basis of CL spectra. Under the optimized conditions, the proposed method allows the measurement of benzhexol hydrochloride over the range 0.1–10 μg/mL with a correlation coefficient of 0.9992 (n = 8), a detection limit of 0.02 μg/mL (3σ), and a relative standard deviation for 2.0 μg/mL benzhexol (n = 11) of 1.65%. The utility of this method was demonstrated by determining benzhexol hydrochloride in tablets. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号