首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The authors assess the equivalence of 2 assays and put forward a general approach for assay agreement analysis that can be applied during drug discovery. Data sets generated by different assays are routinely compared to each other during the process of drug discovery. For a given target, the assays used for high-throughput screening and structure-activity relationship studies will most likely differ in their assay reagents, assay conditions, and/or detection technology, which makes the interpretation of data between assays difficult, particularly as most assays are used to measure quantitative changes in compound potency against the target. To better quantify the relationship of data sets from different assays for the same target, the authors evaluated the agreement between results generated by 2 different assays that measure the activity of compounds against the same protein, ALK5. The authors show that the agreement between data sets can be quantified using correlation and Bland-Altman plots, and the precision of the assays can be used to define the expectations of agreement between 2 assays. They propose a scheme for addressing issues of assay data equivalence, which can be applied to address questions of how data sets compare during the lead identification and lead optimization processes in which assays are frequently added and changed.  相似文献   

2.
High-throughput screening (HTS) for potential anticancer agents requires a broad portfolio of assay platforms that may include kinase enzyme assays, protein-protein binding assays, and functional cell-based apoptosis assays. The authors have explored the use of fluorometric microvolume assay technology (the FMAT 8100 HTS System) in three distinct homogeneous HTS assays: (1). a Src tyrosine kinase enzyme assay, (2). a Grb2-SH2 protein-peptide interaction assay, and (3). an annexin V binding apoptosis assay. Data obtained from all three assays suggest that the FMAT system should facilitate the implementation of homogeneous assays for a wide variety of molecular targeted and cell-based screens.  相似文献   

3.
Numerous diseases are induced by free radicals via lipid peroxidation, protein peroxidation and DNA damage. It has been known that a variety of plant extracts have antioxidant activities to scavenge free radicals. Whether Polygonum cuspidatum Sieb. et Zuce has antioxidant activity is unknown. In this study, dried roots of Polygonum cuspidatum were extracted by ethanol and the extract was lyophilized. Free radical scavenging assays, superoxide radical scavenging assays, lipid peroxidation assays and hydroxyl radical-induced DNA strand scission assays were employed to study antioxidant activities. The results indicate that the IC50 value oí Polygonum cuspidatum extract is 110 microg/ml in free radical scavenging assays, 3.2 microg/ml in superoxide radical scavenging assays, and 8 microg/ml in lipid peroxidation assays, respectively. Furthermore, Polygonum cuspidatum extract has DNA protective effect in hydroxyl radical-induced DNA strand scission assays. The total phenolics and flavonoid content of extract is 641.1 +/- 42.6 mg/g and 62.3 +/- 6.0 mg/g. The results indicate that Polygonum cuspidatum extract clearly has antioxidant effects.  相似文献   

4.
We present the results of a collaborative study for the establishment of a replacement International Standard (IS) for Tetanus Toxoid Adsorbed. Two candidate preparations were included in the study, one of which was established as the 4th IS for Tetanus Toxoid Adsorbed at the WHO Expert Committee on Biological Standardization meeting in October 2010. This preparation was found to have a unitage of 490 IU/ampoule, based on calibration in guinea pig challenge assays. Results from mouse challenge assays suggest that the relative performance of two candidate preparations may differ significantly between guinea pigs and mice. The authors note that the number of laboratories that performed guinea pig challenge assays, which are used to calibrate and assign IU, is much lower than in previous collaborative studies and this may have implications for calibration of replacement standards in the future. The issue of assigning separate units to the IS for guinea pig and mouse assays is discussed. The study also assessed performance of the replacement standard in serological assays which are used as alternative procedures to challenge assays for tetanus potency testing. Results suggest that the replacement standard is suitable for use as the reference vaccine in serological assays.  相似文献   

5.
Immunoassays are a class of analytical techniques based on the selective affinity of a biological antibody for its antigen. Competitive binding assays, of which the radioimmunoassay (RIA) was the first example, are based on the competition between analyte and a labelled probe for a limited number of binding sites. Molecularly imprinted polymers (MIPs) have been shown to be suitable replacements for biological antibodies in such techniques. Molecularly imprinted sorbent assays (MIAs) similar to RIA have been developed for a range of analytes of clinical and environmental interest. Limits of detection and selectivities of such assays are often similar to those using biological antibodies. Some assays have been used for measurements directly in biological fluids. The field is reviewed and it is shown that some perceived disadvantages of MIPs do not hinder their application in competitive binding assays: many MIAs have been demonstrated in aqueous solvents, and it has been shown that the quantity of template required to prepare imprinted polymers can be drastically reduced, and that binding site heterogeneity is not a problem as long as the sites which bind the probe most strongly are selective. Finally, recent developments including assays in microtitre plates, the use of enzyme-labelled probes, flow-injection assays and a scintillation proximity MIA are discussed.  相似文献   

6.
G protein-coupled receptors (GPCRs) represent the single largest molecular target of therapeutic drugs currently on the market, and are also the most common target in high throughput screening assays designed to identify potential new drug candidates. A large percentage of these assays are now formatted as radioligand binding assays. Fluorescence polarization ligand binding assays can offer a non-rad alternative to radioligand binding assays. In addition, fluorescence polarization assays are a homogenous format that is easy to automate for high throughput screening. We have developed a series of peptide ligands labeled with the fluorescent dye BODIPY TMR whose binding to GPCRs can be detected using fluorescence polarization methodology. BODIPY TMR has advantages over the more commonly used fluorescein dye in high throughput screening (HTS) assays due to the fact that its excitation and emission spectra are red-shifted approximately 50 nm relative to fluorescein. Assays based on BODIPY TMR ligands are therefore less susceptible to interference from tissue auto-fluorescence in the assay matrix, or the effects of colored or fluorescent compounds in the screening libraries. A series of BODIPY TMR labeled peptides have been prepared that bind to a range of GPCRs including melanin concentrating hormone, bradykinin, and melanocortin receptors. Conditions have been optimized in order to utilize a comparable amount of receptor membrane preparation as is used in a radioligand binding assay. The assays are formatted in 384-well microplates with a standard volume of 40 microL. We have compared the assays across the different fluorescence polarization (FP) readers available to determine the parameters for each instrument necessary to achieve the required precision.  相似文献   

7.
High throughput drug screening has become a critical component of the drug discovery process. The screening of libraries containing hundreds of thousands of compounds has resulted in a requirement for assays and instrumentation that are amenable to nonradioactive formats and that can be miniaturized. Homogeneous assays that minimize upstream automation of the individual assays are also preferable. Fluorometric microvolume assay technology (FMAT) is a fluorescence-based platform for the development of nonradioactive cell- and bead-based assays for HTS. This technology is plate format-independent, and while it was designed specifically for homogeneous ligand binding and immunological assays, it is amenable to any assay utilizing a fluorescent cell or bead. The instrument fits on a standard laboratory bench and consists of a laser scanner that generates a 1 mm(2) digitized image of a 100-μmm deep section of the bottom of a microwell plate. The instrument is directly compatible with a Zymark Twistertrade mark (Zymark Corp., Hopkinton, MA) for robotic loading of the scanner and unattended operation in HTS mode. Fluorescent cells or beads at the bottom of the well are detected as localized areas of concentrated fluorescence using data processing. Unbound flurophore comprising the background signal is ignored, allowing for the development of a wide variety of homogeneous assays. The use of FMAT for peptide ligand binding assays, immunofluorescence, apoptosis and cytotoxicity, and bead-based immunocapture assays is described here, along with a general overview of the instrument and software.  相似文献   

8.
ABSTRACT

G protein-coupled receptors (GPCRs) represent the single largest molecular target of therapeutic drugs currently on the market, and are also the most common target in high throughput screening assays designed to identify potential new drug candidates. A large percentage of these assays are now formatted as radioligand binding assays. Fluorescence polarization ligand binding assays can offer a non-rad alternative to radioligand binding assays. In addition, fluorescence polarization assays are a homogenous format that is easy to automate for high throughput screening. We have developed a series of peptide ligands labeled with the fluorescent dye BODIPY® TMR whose binding to GPCRs can be detected using fluorescence polarization methodology. BODIPY® TMR has advantages over the more commonly used fluorescein dye in high throughput screening (HTS) assays due to the fact that its excitation and emission spectra are red-shifted approximately 50 nm relative to fluorescein. Assays based on BODIPY® TMR ligands are therefore less susceptible to interference from tissue auto-fluorescence in the assay matrix, or the effects of colored or fluorescent compounds in the screening libraries. A series of BODIPY® TMR labeled peptides have been prepared that bind to a range of GPCRs including melanin concentrating hormone, bradykinin, and melanocortin receptors. Conditions have been optimized in order to utilize a comparable amount of receptor membrane preparation as is used in a radioligand binding assay. The assays are formatted in 384-well microplates with a standard volume of 40 µL. We have compared the assays across the different fluorescence polarization (FP) readers available to determine the parameters for each instrument necessary to achieve the required precision.  相似文献   

9.
High-throughput screening data repositories, such as PubChem, represent valuable resources for the development of small-molecule chemical probes and can serve as entry points for drug discovery programs. Although the loose data format offered by PubChem allows for great flexibility, important annotations, such as the assay format and technologies employed, are not explicitly indexed. The authors have previously developed a BioAssay Ontology (BAO) and curated more than 350 assays with standardized BAO terms. Here they describe the use of BAO annotations to analyze a large set of assays that employ luciferase- and β-lactamase-based technologies. They identified promiscuous chemotypes pertaining to different subcategories of assays and specific mechanisms by which these chemotypes interfere in reporter gene assays. Results show that the data in PubChem can be used to identify promiscuous compounds that interfere nonspecifically with particular technologies. Furthermore, they show that BAO is a valuable toolset for the identification of related assays and for the systematic generation of insights that are beyond the scope of individual assays or screening campaigns.  相似文献   

10.
Several rodent assays are capable of monitoring germline mutation. These include traditional assays, such as the dominant lethal (DL) assay, the morphological specific locus (SL) test and the heritable translocation (HT) assay, and two assays that have been developed more recently--the expanded simple tandem repeat (ESTR) and transgenic rodent (TGR) mutation assays. In this paper, we have compiled the limited amount of experimental data that are currently available to make conclusions regarding the comparative ability of the more recently developed assays to detect germline mutations induced by chemical and radiological agents. The data suggest that ESTR and TGR assays are generally comparable with SL in detecting germline mutagenicity induced by alkylating agents and radiation, though TGR offered less sensitivity than ESTR in some cases. The DL and HT assays detect clastogenic events and are most susceptible to mutations arising in post-spermatogonial cells, and they may not provide the best comparisons with TGR and ESTR instability. The measurement of induced ESTR instability represents a relatively sensitive method of identifying agents causing germline mutation in rodents, and may also be useful for bio-monitoring exposed individuals in the human population. Any future use of the TGR and ESTR germline mutation assays in a regulatory testing context will entail more robust and extensive characterization of assay performance. This will require substantially more data, including experiments measuring multiple endpoints, a greatly expanded database of chemical agents and a focus on characterizing stage-specific activity of mutagens in these assays, preferably by sampling epididymal sperm exposed at defined pre-meiotic, meiotic and post-meiotic stages of development.  相似文献   

11.
Manual cell counts on a microscope are a sensitive means of assessing cellular viability but are time-consuming and therefore expensive. Computerized viability assays are expensive in terms of equipment but can be faster and more objective than manual cell counts. The present report describes the use of three such viability assays. Two of these assays are infrared and one is luminescent. Both infrared assays rely on a 16 bit Odyssey Imager. One infrared assay uses the DRAQ5 stain for nuclei combined with the Sapphire stain for cytosol and is visualized in the 700 nm channel. The other infrared assay, an In-Cell Western, uses antibodies against cytoskeletal proteins (α-tubulin or microtubule associated protein 2) and labels them in the 800 nm channel. The third viability assay is a commonly used luminescent assay for ATP, but we use a quarter of the recommended volume to save on cost. These measurements are all linear and correlate with the number of cells plated, but vary in sensitivity. All three assays circumvent time-consuming microscopy and sample the entire well, thereby reducing sampling error. Finally, all of the assays can easily be completed within one day of the end of the experiment, allowing greater numbers of experiments to be performed within short timeframes. However, they all rely on the assumption that cell numbers remain in proportion to signal strength after treatments, an assumption that is sometimes not met, especially for cellular ATP. Furthermore, if cells increase or decrease in size after treatment, this might affect signal strength without affecting cell number. We conclude that all viability assays, including manual counts, suffer from a number of caveats, but that computerized viability assays are well worth the initial investment. Using all three assays together yields a comprehensive view of cellular structure and function.  相似文献   

12.
Fatty acid amide hydrolase (FAAH) is a pharmaceutical target whose inhibition may lead to valuable therapeutics. Sensitive substrates for high-throughput assays are crucial for the rapid-screening FAAH inhibitors. Here we describe the development of novel and highly sensitive fluorescent assays for FAAH based on substituted aminopyridines. Examining the relationship between the structure and the fluorescence of substituted aminopyridines suggested that a methoxy group in the para position relative to the amino group in aminopyridines greatly increased the fluorescence (i.e., quantum yields approach unity). These novel fluorescent reporters had a high Stokes' shift of 94 nm, and their fluorescence in buffer systems increased with pH values from neutral to basic. Fluorescent substrates with these reporters displayed a very low fluorescent background and high aqueous solubility. Most importantly, fluorescent assays for FAAH based on these substrates were at least 25 times more sensitive than assays using related compounds with published colorimetric or fluorescent reporters. This property results in shorter assay times and decreased protein concentrations in the assays. Such sensitive assays will facilitate distinguishing the relative potency of powerful inhibitors of FAAH. When these fluorescent substrates were applied to human liver microsomes, results suggested that there was at least one amide hydrolase in addition to FAAH that could hydrolyze long-chain fatty acid amides. These results show that these fluorescent substrates are very valuable tools in FAAH activity assays including screening inhibitors by high-throughput assays instead of using the costly and labor-intensive radioactive ligands. Potential applications of novel fluorescent reporters are discussed.  相似文献   

13.
Myosin V is an actin-based motor thought to be involved in vesicle transport. Since the properties of such a motor may be expected to differ from those of muscle myosin II, we have examined myosin V-driven movement using a combination of gliding filament and optical trap assays to observe single molecules with high resolution. The results clearly demonstrate that brain myosin V is a highly efficient processive motor. In vitro motility assays at low myosin V densities reveal apparent single-molecule supported movement. Processive stepping was also observed in optical trapping assays of myosin V-driven motion. Here the methods that were used to demonstrate the processivity of myosin V are described. These methods include density-dependent assays that eliminate the possibility of aggregation or chance colocalization of multiple motors being responsible for apparent single-molecule motility. Such assays will be useful tools for identifying other processive classes of myosins.  相似文献   

14.
Summary: Aggression assays are commonly used to study nestmate recognition in social insects. Methods range from detailed behavioral observations on small numbers of insects to counts of individuals fighting in group interactions. These assays vary in the equipment used and the intensity and duration of observations. We used the Argentine ant, Linepithema humile, to compare four aggression bioassays for consistency between replicates, similarity between assays, and ability to predict whole colony interactions. The assays included were 1 live – 1 dead ant interactions, live 1-1 battles, live 5-5 battles, and 1 ant introduced to a foreign colony. We tested six ant colonies in all pairwise combinations using four different assays and two to three scoring methods per assay. We also conducted a colony merging experiment to see which assays were capable of predicting this ecologically important event. We found that scoring methods within assays yielded very similar results, giving us no reason to favor observationally intense procedures, such as continuous scanning, over less observationally intense systems, such as snapshot surveys. Assays differed greatly in their consistency between replicates. No two replicates of the 1 live – 1 dead assay were significantly correlated. The live 5-5 and the colony introduction assays were the most consistent across replicates. The mean scores of the live 1-1, live 5-5 and colony introduction assays were all significantly correlated with each other; only the live 5-5 assay was significantly correlated with the 1 live – 1 dead assay. Assays that utilized the greatest number of live ants were the most likely to reveal high levels of aggression. The aggression scores of all but the 1 live – 1 dead assay were positively correlated with the number of ants that died during whole colony encounters and negatively associated with colony merging. We conclude that all live ant assays tested are useful tools for analyzing aggressive interactions between colonies, but that the pairing of a live and dead ant produced inconsistent results and generally lower levels of aggression. We found relatively low consistency between trials using the live 1-1 assay, but found that with sufficient replication its results were highly correlated with the assays using more interacting ants. We suggest that isolated aggressive acts in assays do not necessarily predict whole colony interactions: some colonies that fought in bioassays merged when the entire colonies were allowed to interact.  相似文献   

15.
The measurement of multiple antigens in a single sample poses clinical and methodological challenges. Here we describe the validation of a multiplexed sandwich enzyme-linked immunosorbent assay (ELISA) array (microELISA) of nine antigens. The antigens tested simultaneously were: alpha-fetoprotein (AFP), prostate specific antigen (PSA), carcinoembryonic antigen (CEA), cancer antigen 125 (CA 125), CA 15-3, CA 19-9, beta-human chorionic gonadotropin (beta-hCG), luteinizing hormone (LH), and follicle stimulating hormone (FSH). At least 44 clinical samples were tested for each antigen. microELISA results for the nine antigens were then compared with clinical laboratory results obtained for the same antigens in individual chemiluminescent immunoassays. The microELISA had a coefficient of variation (cv) of 7.3% within an assay and 12.6% for assays run at different times. A statistical comparison of results from the microELISA with results from the clinical laboratory showed that the assays had correlation coefficients ranging from 0.99 to 0.76, and Deming regression demonstrated that four of the nine assays were high-quality assays and not statistically different to the individual assays. To determine if the differences in the assays were due to methodology, the microELISA was also compared with conventional ELISAs using identical antibodies and reagents. Deming regression demonstrated that five of the eight assays were high-quality, indicating that a poor correlation between a microELISA and an individual immunoassay are partly due to antibody differences.  相似文献   

16.
Skeletal muscle mitochondria play a specific role in many disease pathologies. As such, the measurement of oxygen consumption as an indicator of mitochondrial function in this tissue has become more prevalent. Although many technologies and assays exist that measure mitochondrial respiratory pathways in a variety of cells, tissue and species, there is currently a void in the literature in regards to the compilation of these assays using isolated mitochondria from mouse skeletal muscle for use in microplate based technologies. Importantly, the use of microplate based respirometric assays is growing among mitochondrial biologists as it allows for high throughput measurements using minimal quantities of isolated mitochondria. Therefore, a collection of microplate based respirometric assays were developed that are able to assess mechanistic changes/adaptations in oxygen consumption in a commonly used animal model. The methods presented herein provide step-by-step instructions to perform these assays with an optimal amount of mitochondrial protein and reagents, and high precision as evidenced by the minimal variance across the dynamic range of each assay.  相似文献   

17.

Background

Neutralizing antibody assessments play a central role in human immunodeficiency virus type-1 (HIV-1) vaccine development but it is unclear which assay, or combination of assays, will provide reliable measures of correlates of protection. To address this, an international collaboration (NeutNet) involving 18 independent participants was organized to compare different assays.

Methods

Each laboratory evaluated four neutralizing reagents (TriMab, 447-52D, 4E10, sCD4) at a given range of concentrations against a panel of 11 viruses representing a wide range of genetic subtypes and phenotypes. A total of 16 different assays were compared. The assays utilized either uncloned virus produced in peripheral blood mononuclear cells (PBMCs) (virus infectivity assays, VI assays), or their Env-pseudotyped (gp160) derivatives produced in 293T cells (PSV assays) from molecular clones or uncloned virus. Target cells included PBMC and genetically-engineered cell lines in either a single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs that included extracellular or intracellular p24 antigen detection, RNA quantification and luciferase and beta-galactosidase reporter gene expression.

Findings

PSV assays were generally more sensitive than VI assays, but there were important differences according to the virus and inhibitor used. For example, for TriMab, the mean IC50 was always lower in PSV than in VI assays. However, with 4E10 or sCD4 some viruses were neutralized with a lower IC50 in VI assays than in the PSV assays. Inter-laboratory concordance was slightly better for PSV than for VI assays with some viruses, but for other viruses agreement between laboratories was limited and depended on both the virus and the neutralizing reagent.

Conclusions

The NeutNet project demonstrated clear differences in assay sensitivity that were dependent on both the neutralizing reagent and the virus. No single assay was capable of detecting the entire spectrum of neutralizing activities. Since it is not known which in vitro assay correlates with in vivo protection, a range of neutralization assays is recommended for vaccine evaluation.  相似文献   

18.
Polymerase chain reaction (PCR) assays have proven useful for detection of rodent parvoviruses in animals and contaminated biological materials. Fluorogenic nuclease PCR assays combine PCR with an internal fluorogenic hybridization probe, eliminating post-PCR processing and potentially enhancing specificity. Consequently, three fluorogenic nuclease PCR assays were developed, one that detects all rodent parvoviruses, one that specifically detects minute virus of mice (MVM), and one that specifically detects mouse parvovirus 1 (MPV) and hamster parvovirus (HaPV). When rodent parvoviruses and other rodent DNA viruses were evaluated, the rodent parvovirus assay detected only rodent parvovirus isolates, whereas the MVM and MPV/HaPV assays detected only the MVM or MPV/ HaPV isolates, respectively. Each assay detected the equivalent of 10 or fewer copies of target template, and all fluorogenic nuclease PCR assays exceeded the sensitivities associated with previously reported PCR assays and mouse antibody production testing. In addition, each fluorogenic nuclease PCR assay detected the targeted parvovirus DNA in tissues obtained from mice experimentally infected with MVM or MPV. Results of these studies indicate that fluorogenic nuclease PCR assays provide a potentially high-throughput, PCR-based method to detect rodent parvoviruses in infected mice and contaminated biological materials.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号