首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.

Purpose

To assess the correlation and agreement between the Topcon built-in algorithm and our graph-based algorithm in measuring the total and regional macular thickness for normal and glaucoma subjects.

Methods

A total of 228 normal eyes and 93 glaucomatous eyes were enrolled in our study. All patients underwent comprehensive ophthalmic examination and Topcon 3D-OCT 2000 scan. One eye was randomly selected for each subject. The thickness of each layer and the total and regional macular thickness on an Early Treatment of Diabetic Retinopathy Study (ETDRS) chart were measured using the Topcon algorithm and our three-dimensional graph-based algorithm. Correlation and agreement analyses between these two algorithms were performed.

Results

Our graph search algorithm exhibited a strong correlation with Topcon algorithm. The macular GCC thickness values for normal and glaucoma subjects ranged from 0.86 to 0.91 and from 0.78 to 0.90, and the regional macular thickness values ranged from 0.79 to 0.96 and 0.70 to 0.95, respectively. Small differences were observed between the Topcon algorithm and our graph-based algorithm. The span of 95% limits of agreement of macular GCC thickness was less than 28 μm in both normal and glaucoma subjects, respectively. These limits of total and regional macular thickness were 15.5 μm and 23.1 μm for normal subjects and 29.1 μm and 46.4 μm for glaucoma subjects, respectively.

Conclusion

Our graph-based algorithm exhibited a high degree of agreement with the Topcon algorithm with respect to thickness measurements in normal and glaucoma subjects. Moreover, our graph-based algorithm can segment the retina into more layers than the Topcon algorithm does.  相似文献   

3.

Objective

Ultrasound is considered a safe imaging modality and is routinely applied during early pregnancy. However, reservations are expressed concerning the application of Doppler ultrasound in early pregnancy due to energy emission of the ultrasound probe and its conversion to heat. The objective of this study was to evaluate the thermal effects of emitted Doppler ultrasound of different ultrasound machines and probes by means of temperature increase of in-vitro test-media.

Methods

We investigated the energy-output of 5 vaginal and abdominal probes of 3 ultrasound machines (GE Healthcare, Siemens, Aloka). Two in-vitro test objects were developed at the Center for Medical Physics and Biomedical Engineering, Medical University Vienna (water bath and hydrogel bath). Temperature increase during Doppler ultrasound emission was measured via thermal sensors, which were placed inside the test objects or on the probes’ surface. Each probe was emitting for 5 minutes into the absorbing test object with 3 different TI/MI settings in Spectral Doppler mode.

Results

During water bath test, temperature increase varied between 0.1 and 1.0°C, depending on probe, setting and focus, and was found highest for spectral Doppler mode alone. Maximum temperature increase was found during the surface heating test, where values up to 2.4°C could be measured within 5 minutes of emission.

Conclusions

Activation of Doppler ultrasound in the waterbath model causes a significant increase of temperature within one minute. Thermally induced effects on the embryo cannot be excluded when using Doppler ultrasound in early pregnancy.  相似文献   

4.

Purpose

To evaluate the intrasession reproducibility of various thickness parameters used to diagnose and follow-up glaucoma, in particular circumpapillary total retinal thickness (cpTR) provided by the RS-3000 optical coherence tomograph (OCT).

Methods

Fifty-three healthy eyes of 28 subjects underwent three consecutive imaging with the RS-3000 Advance OCT (NIDEK, Aichi,Japan) to evaluate the intrasession reproducibility of circumpapillary total retinal thickness (cpTR), circumpapillary retinal nerve fiber layer thickness (cpRNFL), macular ganglion cell complex thickness (mGCC) and macular total retina thickness (mTR) measurements. Intraclass correlation (ICC), coefficient of variation (CV) and reproducibility coefficient (RC) were calculated for each parameter.

Results

The ICC and CV values for mean cpTR and cpRNFL were 0.987 and 0.897, and 0.60% and 2.81%, respectively. The RC values for the mean cpTR and cpRNFL were 5.95 μm and 9.04 μm, respectively. For all cpTR parameters the ICC values were higher and both the CV and RC values were lower than those for the corresponding cpRNFL parameters. The ICC and CV values for superior mGCC, inferior mGCC, superior mTR and inferior mTR were 0.983, 0.980, 0.983 and 0.988, and 0.84%, 0.98%, 0.48% and 0.43%, respectively. The RC values for superior mGCC, inferior mGCC, superior mTR and inferior mTR were 2.86 μm, 3.12 μm, 4.41μm and 4.43 μm, respectively.

Conclusions

Intrasession reproducibility of cpTR, mGCC and mTR measurements made on healthy eyes was high. Repeatability of cpTR measurements was better than that of the corresponding cpRNFL measurements. These results suggest that future clinical investigations addressing detection of glaucoma and glaucomatous progression with the RS-3000 OCT may benefit from focusing on the cpTR parameters.  相似文献   

5.

Background

Air pollution is one of the most environmental health concerns in the world and has serious impact on human health, particularly in the mucous membranes of the respiratory tract and eyes. However, ocular hazardous effects to air pollutants are scarcely found in the literature.

Design

Panel study to evaluate the effect of different levels of ambient air pollution on lacrimal film cytokine levels of outdoor workers from a large metropolitan area.

Methods

Thirty healthy male workers, among them nineteen professionals who work on streets (taxi drivers and traffic controllers, high pollutants exposure, Group 1) and eleven workers of a Forest Institute (Group 2, lower pollutants exposure compared to group 1) were evaluated twice, 15 days apart. Exposure to ambient PM2.5 (particulate matter equal or smaller than 2.5 μm) was 24 hour individually collected and the collection of tears was performed to measure interleukins (IL) 2, 4, 5 and 10 and interferon gamma (IFN-γ) levels. Data from both groups were compared using Student’s t test or Mann- Whitney test for cytokines. Individual PM2.5 levels were categorized in tertiles (lower, middle and upper) and compared using one-way ANOVA. Relationship between PM2.5 and cytokine levels was evaluated using generalized estimating equations (GEE).

Results

PM2.5 levels in the three categories differed significantly (lower: ≤22 μg/m3; middle: 23–37.5 μg/m3; upper: >37.5 μg/m3; p<0.001). The subjects from the two groups were distributed unevenly in the lower category (Group 1 = 8%; Group 2 = 92%), the middle category (Group 1 = 89%; Group 2 = 11%) and the upper category (Group 1 = 100%). A significant relationship was found between IL-5 and IL-10 and PM2.5 levels of the group 1, with an average decrease of 1.65 pg/mL of IL-5 level and of 0.78 pg/mL of IL-10 level in tear samples for each increment of 50 μg/m3 of PM2.5 (p = 0.01 and p = 0.003, respectively).

Conclusion

High levels of PM2.5 exposure is associated with decrease of IL-5 and IL-10 levels suggesting a possible modulatory action of ambient air pollution on ocular surface immune response.  相似文献   

6.

Purpose

To investigate the thickness of the retinal layers and to assess the prevalence of macular microcysts (MM) in the inner nuclear layer (INL) of patients with mitochondrial optic neuropathies (MON).

Methods

All patients with molecularly confirmed MON, i.e. Leber’s Hereditary Optic Neuropathy (LHON) and Dominant Optic Atrophy (DOA), referred between 2010 and 2012 were enrolled. Eight patients with MM were compared with two control groups: MON patients without MM matched by age, peripapillary retinal nerve fiber layer (RNFL) thickness, and visual acuity, as well as age-matched controls. Retinal segmentation was performed using specific Optical coherence tomography (OCT) software (Carl Zeiss Meditec). Macular segmentation thickness values of the three groups were compared by one-way analysis of variance with Bonferroni post hoc corrections.

Results

MM were identified in 5/90 (5.6%) patients with LHON and 3/58 (5.2%) with DOA. The INL was thicker in patients with MON compared to controls regardless of the presence of MM [133.1±7μm vs 122.3±9μm in MM patients (p<0.01) and 128.5±8μm vs. 122.3±9μm in no-MM patients (p<0.05)], however the outer nuclear layer (ONL) was thicker in patients with MM (101.4±1mμ) compared to patients without MM [77.5±8mμ (p<0.001)] and controls [78.4±7mμ (p<0.001)]. ONL thickness did not significantly differ between patients without MM and controls.

Conclusion

The prevalence of MM in MON is low (5-6%), but associated with ONL thickening. We speculate that in MON patients with MM, vitreo-retinal traction contributes to the thickening of ONL as well as to the production of cystic spaces.  相似文献   

7.

Background

Stilbene-based compounds show antitumoral, antioxidant, antihistaminic, anti-inflammatory and antimicrobial activities. Here, we evaluated the effect of the trans-resveratrol analogs, pterostilbene, piceatannol, polydatin and oxyresveratrol, against Leishmania amazonensis.

Methodology/Principal Findings

Our results demonstrated a low murine macrophage cytotoxicity of all four analogs. Moreover, pterostilbene, piceatannol, polydatin and oxyresveratrol showed an anti-L. amazonensis activity with IC50 values of 18 μM, 65 μM, 95 μM and 65 μM for promastigotes, respectively. For intracellular amastigotes, the IC50 values of the analogs were 33.2 μM, 45 μM, 29 μM and 30.5 μM, respectively. Among the analogs assayed only piceatannol altered the cell cycle of the parasite, increasing 5-fold the cells in the Sub-G0 phase and decreasing 1.7-fold the cells in the G0-G1 phase. Piceatannol also changed the parasite mitochondrial membrane potential (ΔΨm) and increased the number of annexin-V positive promastigotes, which suggests incidental death.

Conclusion/Significance

Among the analogs tested, piceatannol, which is a metabolite of resveratrol, was the more promising candidate for future studies regarding treatment of leishmaniasis.  相似文献   

8.

Objective

To prepare arginine-glycine-aspartate (RGD)-targeted ultrasound contrast microbubbles (MBs) and explore the feasibility of their use in assessing dynamic changes in αvβ3 integrin expression in a murine model of tumor angiogenesis.

Methods

RGD peptides were conjugated to the surfaces of microbubbles via biotin-avidin linkage. Microbubbles bearing RADfK peptides were prepared as controls. The RGD-MBs were characterized using an Accusizer 780 and optical microscopy. The binding specificity of the RGD-MBs for ανβ3-expressing endothelial cells (bEnd.3) was demonstrated in vitro by a competitive inhibition experiment. In an in vivo study, mice bearing tumors of three different stages were intravenously injected with RGD-MBs and subjected to targeted, contrast-enhanced, high-frequency ultrasound. Subsequently, tumors were harvested and sectioned for immunofluorescence analysis of ανβ3 expression.

Results

The mean size of the RGD-MBs was 2.36 ± 1.7 μm. The RGD-MBs showed significantly higher adhesion levels to bEnd.3 cells compared to control MBs (P < 0.01). There was rarely binding of RGD-MBs to αvβ3-negative MCF-7 cells. Adhesion of the RGD-MBs to the bEnd.3 cells was significantly inhibited following treatment with anti-alpha(v) antibodies. The quantitative acoustic video intensity for high-frequency, contrast-enhanced ultrasound imaging of subcutaneous human laryngeal carcinoma (Hep-2) tumor xenografts was significantly higher in small tumors (19.89 ± 2.49) than in medium tumors (11.25 ± 2.23) and large tumors (3.38 ± 0.67) (P < 0.01).

Conclusions

RGD-MBs enable noninvasive in vivo visualization of changes in tumor angiogenesis during tumor growth in subcutaneous cancer xenografts.  相似文献   

9.

Purpose

To investigate the characteristics of macular ganglion cell-inner plexiform layer (GCIPL) thickness profiles associated with ocular dominance.

Setting

Private practice, Seoul, Republic of Korea.

Design

Comparative case-control study.

Methods

Both eyes of 199 participants with no ophthalmic abnormalities were included. Participants were imaged by spectral-domain optical coherence tomography, and underwent dominant eye testing using a hole-in-a-card test (sighting dominance) at the same visit. Macular GCIPL, as well as circumpapillary retinal nerve fiber layer (RNFL) thickness were compared for individual patients, according to ocular dominance.

Results

Ocular dominance occurred predominantly in the right eye (right vs. left: 72.36 vs. 27.60%; P < 0.001). In the comparison of macular GCIPL thickness, the average (81.27±5.01 μm vs. 80.66±6.31 μm in dominant vs. non-dominant eyes), inferonasal (81.39±5.47μm vs. 80.33±6.82μm, and inferior sectors (77.95±6.05μm vs. 76.97±8.15μm) were significantly different between dominant and non-dominant eyes (P = 0.040, 0.005, and 0.032, respectively). Significant predictors of average GCIPL thickness were spherical equivalent (β = 1.37, P<0.001), astigmatic power (β = 1.44, P = 0.009), disc area (β = 3.90, P < 0.001), average RNFL thickness (β = 0.22, P<0.001), average cup-to-disc ratio (β = 5.74, P = 0.002), difference between the inferior and superior quadrant RNFL thicknesses (β = 0.08, P = 0.024), and ocular dominance (β = 2.10, P = 0.020). On multivariate regression analysis, ocular dominance was correlated with average GCIPL thickness after adjusting for potential confounders (β = 1.63, P = 0.048).

Conclusions

Dominant eyes accompanied significantly thicker average macular GCIPL. This information suggests that macular GCIPL thickness may provide an indicator of the relative dominance of an eye.  相似文献   

10.

Purpose

To investigate repeatability and reproducibility of thickness of eight individual retinal layers at axial and lateral foveal locations, as well as foveal width, measured from Spectralis spectral domain optical coherence tomography (SD-OCT) scans using newly available retinal layer segmentation software.

Methods

High-resolution SD-OCT scans were acquired for 40 eyes of 40 young healthy volunteers. Two scans were obtained in a single visit for each participant. Using new Spectralis segmentation software, two investigators independently obtained thickness of each of eight individual retinal layers at 0°, 2° and 5° eccentricities nasal and temporal to foveal centre, as well as foveal width measurements. Bland-Altman Coefficient of Repeatability (CoR) was calculated for inter-investigator and inter-scan agreement of all retinal measurements. Spearman''s ρ indicated correlation of manually located central retinal thickness (RT0) with automated minimum foveal thickness (MFT) measurements. In addition, we investigated nasal-temporal symmetry of individual retinal layer thickness within the foveal pit.

Results

Inter-scan CoR values ranged from 3.1μm for axial retinal nerve fibre layer thickness to 15.0μm for the ganglion cell layer at 5° eccentricity. Mean foveal width was 2550μm ± 322μm with a CoR of 13μm for inter-investigator and 40μm for inter-scan agreement. Correlation of RT0 and MFT was very good (ρ = 0.97, P < 0.0005). There were no significant differences in thickness of any individual retinal layers at 2° nasal compared to temporal to fovea (P > 0.05); however this symmetry could not be found at 5° eccentricity.

Conclusions

We demonstrate excellent repeatability and reproducibility of each of eight individual retinal layer thickness measurements within the fovea as well as foveal width using Spectralis SD-OCT segmentation software in a young, healthy cohort. Thickness of all individual retinal layers were symmetrical at 2°, but not at 5° eccentricity away from the fovea.  相似文献   

11.

Background

After the implementation of the universal salt iodization (USI) program in 1996, seven cross-sectional school-based surveys have been conducted to monitor iodine deficiency disorders (IDD) among children in eastern China.

Objectives

This study aimed to examine the correlation of total goiter rate (TGR) with average thyroid volume (Tvol) and urinary iodine concentration (UIC) in Jiangsu province after IDD elimination.

Design

Probability-proportional-to-size sampling was applied to select 1,200 children aged 8–10 years old in 30 clusters for each survey in 1995, 1997, 1999, 2001, 2002, 2005, 2009 and 2011. We measured Tvol using ultrasonography in 8,314 children and measured UIC (4,767 subjects) and salt iodine (10,184 samples) using methods recommended by the World Health Organization. Tvol was used to calculate TGR based on the reference criteria specified for sex and body surface area (BSA).

Results

TGR decreased from 55.2% in 1997 to 1.0% in 2009, and geometric means of Tvol decreased from 3.63 mL to 1.33 mL, along with the UIC increasing from 83 μg/L in 1995 to 407 μg/L in 1999, then decreasing to 243 μg/L in 2005, and then increasing to 345 μg/L in 2011. In the low goiter population (TGR < 3.9%), TGR was positively associated with average Tvol (r = 0.99); UIC showed a non-linear association with average Tvol, and UIC > 300 μg/L was associated with a smaller average Tvol in children.

Conclusions

After IDD elimination in Jiangsu province in 2001, lower TGR was associated with smaller average Tvol. Average Tvol was more sensitive than TGR in detecting the fluctuation of UIC. A UIC of 300 μg/L may be defined as a critical value for population level iodine status monitoring.  相似文献   

12.

Objective

Gas microembolism remains a serious risk associated with surgical procedures and decompression. Despite this, the signaling consequences of air bubbles in the vasculature are poorly understood and there is a lack of pharmacological therapies available. Here, we investigate the mitochondrial consequences of air bubble contact with endothelial cells.

Methods and Results

Human umbilical vein endothelial cells were loaded with an intracellular calcium indicator (Fluo-4) and either a mitochondrial calcium indicator (X-Rhod-1) or mitochondrial membrane potential indicator (TMRM). Contact with 50–150 µm air bubbles induced concurrent rises in intracellular and mitochondrial calcium, followed by a loss of mitochondrial membrane potential. Pre-treating cells with 1 µmol/L ruthenium red, a TRPV family calcium channel blocker, did not protect cells from the mitochondrial depolarization, despite blocking the intracellular calcium response. Mitigating the interactions between the air-liquid interface and the endothelial surface layer with 5% BSA or 0.1% Pluronic F-127 prevented the loss of mitochondrial membrane potential. Finally, inhibiting protein kinase C-α (PKCα), with 5 µmol/L Gö6976, protected cells from mitochondrial depolarization, but did not affect the intracellular calcium response.

Conclusions

Our results indicate that air bubble contact with endothelial cells activates a novel, calcium-independent, PKCα-dependent signaling pathway, which results in mitochondrial depolarization. As a result, mitochondrial dysfunction is likely to be a key contributor to the pathophysiology of gas embolism injury. Further, this connection between the endothelial surface layer and endothelial mitochondria may also play an important role in vascular homeostasis and disease.  相似文献   

13.

Purpose

To determine the impact of flap creation methods for sub-Bowman’s keratomileusis (SBK) on central Bowman’s layer thickness.

Methods

SBK flaps were made by Moria microkeratome for 20 subjects and by femtosecond (FEMTO) laser for 21 subjects. Corneal sublayer thicknesses were measured by ultra-high resolution optical coherence tomography before SBK and at 1 day, 1 week, 2 weeks, and 1 month afterwards. Each subject was imaged twice on each visit. Thicknesses of central epithelium, Bowman’s layer, flap, and total cornea were calculated using a custom-made automated image processing algorithm. The repeatability of sublayer thickness measurements was tested by the intraclass correlation coefficient (ICC) and by the coefficient of repeatability (CoR) at 1 week post-SBK.

Results

ICCs of the Moria and FEMTO groups were ≥0.959 and ≥0.961 respectively for all sublayer measurements. The segmentation CoRs were less than 6.78% and 5.63% respectively. For both groups, microdistortions were present in the epithelium and Bowman’s layer after SKB. The flap thickness of the Moria group was 9.8 μm (95% confidence interval: 4.8 – 14.8μm) thinner than the FEMTO group one day after SBK (independent samples t-test, P < 0.05). Bowman’s layer became thicker by 1.6 ± 1.1 μm and 1.7 ± 1.6 μm one day post-SBK for the Moria and FEMTO groups (repeated ANOVA, P < 0.05) and then remained stable. Corneal and sublayer thickness were similar between the two groups.

Conclusions

Central Bowman’s layer thickness increased 1 day post-SBK. Flap creation by Moria microkeratome and femtosecond laser did not have significantly different impacts on Bowman’s layer thickness following SBK.

Trial Registration

Chinese Clinical Trial Registry (ChiCTR) NO: ChiCTR-OCH-14004525  相似文献   

14.

Purpose

To improve the reliability of corneal topographic data through the development of a method to estimate the magnitude of misalignment between successive corneal videokeratography (VK) maps and eliminate the effect of misalignment on the repeatability of topography data.

Methods

Anterior and posterior topography maps were recorded twice for 124 healthy eyes of 124 participants using a Pentacam, and the repeatability of measurements was assessed by calculating the differences in elevation between each two sets of data. The repeatability of measurements was re-assessed following the determination of the magnitude of misalignment components (translational displacements: x0, y0 and z0, and rotational displacements: α, β and γ) between each two data sets and using them to modify the second data set within each pair based on an Iterative Closest Point (ICP) algorithm. The method simultaneously considered the anterior and posterior maps taken for the same eye since they were assumed to have the same set of misalignment components. A new parameter, named Combined Misalignment parameter (CM), has been developed to combine the effect of all six misalignment components on topography data and so enable study of the association between misalignment and the data repeatability test results.

Results

The repeatability tests resulted in average root mean square (RMS) differences in elevation data of 8.46±2.75 μm before ICP map matching when simultaneously considering anterior and posterior surfaces. With map matching and misalignment correction, the differences decreased to 7.28±2.58 μm (P = 0.00). When applied to only the anterior maps, misalignment correction led to a more pronounced reduction in elevation data differences from 4.58±1.84 μm to 2.97±1.29 μm (P = 0.00). CM was found to be associated with the repeatability error (P = 0.00), with posterior maps being responsible for most of the error due to their relatively lower accuracy compared to anterior maps.

Conclusions

The ICP algorithm can be used to estimate, and effectively correct for, the potential misalignment between successive corneal videokeratography maps.  相似文献   

15.

Objective

Finely resolved PM2.5 exposure measurements at the level of individual participants or over a targeted geographic area can be challenging due to the cost, size and weight of the monitoring equipment. We propose re-purposing the low-cost, portable and lightweight Shinyei PPD42NS particle counter as a particle counting device. Previous field deployment of this sensor suggests that it captures trends in ambient PM2.5 concentrations, but important characteristics of the sensor response have yet to be determined. Laboratory testing was undertaken in order to characterize performance.

Methods

The Shinyei sensors, in-line with a TSI Aerosol Particle Sizer (APS) model 3321, tracked particle decay within an aerosol exposure chamber. Test atmospheres were composed of monodisperse polystyrene spheres with diameters of 0.75, 1, 2 3 and 6 um as well as a polydisperse atmosphere of ASHRAE test dust #1.

Results

Two-minute block averages of the sensor response provide a measurement with low random error, within sensor, for particles in the 0.75–6μm range with a limit of detection of 1 μg/m3. The response slope of the sensors is idiomatic, and each sensor requires a unique response curve. A linear model captures the sensor response for concentrations below 50 μg/m3 and for concentrations above 50 μg/m3 a non-linear function captures the response and saturates at 800 μg/m3. The Limit of Detection (LOD) is 1 μg/m3. The response time is on the order of minutes, making it appropriate for tracking short-term changes in concentration.

Conclusions

When paired with prior evaluation, these sensors are appropriate for use as ambient particle counters for low and medium concentrations of respirable particles (< 100 ug/m3). Multiple sensors deployed over a spatial grid would provide valuable spatio-temporal variability in PM2.5 and could be used to validate exposure models. When paired with GPS tracking, these devices have the potential to provide time and space resolved exposure measurements for a large number of participants, thus increasing the power of a study.  相似文献   

16.

Objectives

In this study, we develop a microdensitometry method using full width at half maximum (FWHM) analysis of the retinal vascular structure in a spectral-domain optical coherence tomography (SD-OCT) image and present the application of this method in the morphometry of arteriolar changes during hypertension.

Methods

Two raters using manual and FWHM methods measured retinal vessel outer and lumen diameters in SD-OCT images. Inter-rater reproducibility was measured using coefficients of variation (CV), intraclass correlation coefficient and a Bland-Altman plot. OCT images from forty-three eyes of 43 hypertensive patients and 40 eyes of 40 controls were analyzed using an FWHM approach; wall thickness, wall cross-sectional area (WCSA) and wall to lumen ratio (WLR) were subsequently calculated.

Results

Mean difference in inter-rater agreement ranged from -2.713 to 2.658 μm when using a manual method, and ranged from -0.008 to 0.131 μm when using a FWHM approach. The inter-rater CVs were significantly less for the FWHM approach versus the manual method (P < 0.05). Compared with controls, the wall thickness, WCSA and WLR of retinal arterioles were increased in the hypertensive patients, particular in diabetic hypertensive patients.

Conclusions

The microdensitometry method using a FWHM algorithm markedly improved inter-rater reproducibility of arteriolar morphometric analysis, and SD-OCT may represent a promising noninvasive method for in vivo arteriolar morphometry.  相似文献   

17.

Introduction

Risk factors for breast milk transmission of HIV-1 from mother to child include high plasma and breast milk viral load, low maternal CD4 count and breast pathology such as mastitis.

Objective

To determine the impact of nevirapine and subclinical mastitis on HIV-1 RNA in maternal plasma and breast milk after intrapartum single-dose nevirapine combined with either 1-week tail of Combivir (zidovudine/lamivudine) or single-dose Truvada (tenofovir/emtricitabine).

Methods

Maternal plasma and bilateral breast milk samples were collected between April 2008 and April 2011 at 1, 4 and 6 weeks postpartum from HIV-infected Tanzanian women. Moreover, plasma samples were collected at delivery from mother and infant.

Results

HIV-1 RNA was quantified in 1,212 breast milk samples from 273 women. At delivery, 96% of the women and 99% of the infants had detectable nevirapine in plasma with a median (interquartile range, IQR) of 1.5 μg/mL (0.75–2.20 μg/mL) and 1.04 μg/mL (0.39–1.71 μg/mL), respectively (P < 0.001). At 1 week postpartum, 93% and 98% of the women had detectable nevirapine in plasma and breast milk, with a median (IQR) of 0.13 μg/mL (0.13–0.39 μg/mL) and 0.22 μg/mL (0.13–0.34 μg/mL), respectively. Maternal plasma and breast milk HIV-1 RNA correlated at all visits (R = 0.48, R = 0.7, R = 0.59; all P = 0.01). Subclinical mastitis was detected in 67% of the women at some time during 6 weeks, and in 38% of the breast milk samples. Breast milk samples with subclinical mastitis had significantly higher HIV-1 RNA at 1, 4 and 6 weeks (all P < 0.05).

Conclusion

After short-course antiretroviral prophylaxis, nevirapine was detectable in most infant cord blood samples and the concentration in maternal plasma and breast milk was high through week 1 accompanied by suppressed HIV-1 RNA in plasma and breast milk.  相似文献   

18.

Background and Objective

Cat allergen concentrations higher than 8 μg/g in settled house dust, have been suggested to provoke exacerbation of allergic respiratory symptoms. However, whether the 8μg/g of indoor cat allergen concentration is indeed the minimal exposure required for triggering the asthma related respiratory symptoms or the development of sensitization has not yet been confirmed. We studied the associations between domestic cat allergen concentrations and allergic symptoms in the European Community Respiratory Health Survey II, with the aim of confirming this suggested threshold.

Methods

Cat allergen concentrations were measured in the mattress dust of 3003 participants from 22 study centres. Levels of specific immunoglobulin E to cat allergens were measured in serum samples using an immunoassay. Information on allergic symptoms, medication use, home environment and smoking was obtained from a face-to-face interview.

Results

Domestic cat allergen concentrations were not associated with allergic/ asthmatic symptoms in the entire study population, nor in the subset sensitized to cat allergen. We also found no association among individuals exposed to concentrations higher than 8 μg/g. However, exposure to medium cat allergen concentrations (0.24-0.63 μg/g) was positively associated with reported asthmatic respiratory symptoms in subjects who have experienced allergic symptoms when near animals.

Conclusions

The proposed 8 μg/g threshold of cat allergen concentrations for the exacerbation of allergic/ respiratory symptoms was not confirmed in a general European adult population. Potential biases attributable to avoidance behaviours and an imprecise exposure assessment cannot be excluded.  相似文献   

19.

Background

The rate and extent of CD4 cell recovery varies widely among HIV-infected patients with different baseline CD4 cell count strata. The objective of the study was to assess trends in CD4 cell counts in HIV-infected patients after initiation of antiretroviral therapy in Tigray, Northern Ethiopia.

Methods

A retrospective cross-sectional study was conducted by reviewing medical records of HIV patients who received antiretroviral treatment at twenty health centers in Tigray region during 2008–2012. Multi-stage cluster sampling technique was employed to collect data, and the data were analyzed using SPSS version 20.0 software.

Results

The median change from baseline to the most recent CD4 cell count was +292 cells/μl. By 5 years, the overall median (inter-quartile range, IQR) CD4 cell count was 444(263-557) cells/μl while the median (IQR) CD4 cell count was 342(246-580) cells/μl among patients with baseline CD4 cell counts ≤200 cells/μl, 500(241-557) cells/μl among those with baseline CD4 cell counts of 201–350 cells/μl, and 652(537-767) cells/μl among those with baseline CD4 cell counts >350 cells/μl. Higher baseline CD4 cell counts and being male were independently associated with the risk of immunological non-response at 12 months. Furthermore, it was also investigated that these factors were significant predictors of subsequent CD4 cell recovery.

Conclusions

Patients with higher baseline CD4 cell stratum returned to normal CD4 Cell counts though they had an increased risk of immunological non-response at 12 months compared to those with the least baseline CD4 cell stratum. The findings suggest that consideration be given to initiation of HAART at a CD4 cell count >350 cells/μl to achieve better immune recovery, and to HIV-infected male patients to improve their health seeking behavior.  相似文献   

20.

Purpose

To describe the ethnic differences in central corneal thickness (CCT) in population-based samples of ethnic Bai, Yi and Han people living in rural China.

Methods

6504 adults (2119 ethnic Bai, 2202 ethnic Yi and 2183 ethnic Han) aged 50 years or older participated in the study. Each subject underwent standardized ocular examinations and interviewer-administered questionnaires for risk factor assessment. CCT was measured for both eyes using an ultrasound pachymeter. Regression and principal component analysis were performed to examine the relationship of ethnicity and other factors with CCT.

Results

The mean CCT readings were 536.4 ± 34.2 μm in ethnic Bai, 532.1 ± 32.1 μm in ethnic Yi and 529.6 ± 32.7 μm in ethnic Han adults (P<0.001), respectively. There was a decreasing trend of mean CCT with increasing age across all ethnic groups. In multivariate linear regression models, increasing CCT was associated with younger age (P<0.001), male gender (P<0.001), Bai (P<0.001) or Yi (P<0.001) ethnicity, greater body mass index (P<0.001), higher systolic blood pressure (P<0.001), greater corneal curvature (P<0.001), deeper anterior chamber (P < 0.001), and thicker lens (P<0.001). Ethnicity contributed significantly to presence of thin cornea (60%; P< 0.001) compared with other factors. CCT had similar impact on intraocular pressure readings across all ethnic groups.

Conclusions

This study of more than 6500 multiethnic participants demonstrates significant ethnic variations in CCT, with Han ethnicity having the thinnest cornea compared with ethnic minorities. These data are essential to guide future multiethnic clinical trials on CCT-related ocular conditions such as glaucoma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏