首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
The aim of this study was to test the influence of oxygen affinity of Hb vesicles (HbVs) and level of blood exchange on the oxygenation in collateralized, ischemic, and hypoxic hamster flap tissue during normovolemic hemodilution. Microhemodynamics were investigated with intravital microscopy. Tissue Po2 was measured with Clark-type microprobes. HbVs with a P50 of 15 mmHg (HbV15) and 30 mmHg (HbV30) were suspended in 6% Dextran 70 (Dx70). The Hb concentration of the solutions was 7.5 g/dl. A stepwise replacement of 15%, 30%, and 50% of total blood volume was performed, which resulted in a gradual decrease in total Hb concentration. In the ischemic tissue, hemodilution led to an increase in microvascular blood flow to maximally 141-166% of baseline in all groups (median; P < 0.01 vs. baseline, not significant between groups). Oxygen tension was transiently raised to 121 +/- 17% after the 30% blood exchange with Dx70 (P < 0.05), whereas it was increased after each step of hemodilution with HbV15-Dx70 and HbV30-Dx70, reaching 217 +/- 67% (P < 0.01) and 164 +/- 33% (P < 0.01 vs. baseline and other groups), respectively, after the 50% blood exchange. We conclude that despite a decrease in total Hb concentration, the oxygenation in the ischemic, hypoxic tissue could be improved with increasing blood exchange with HbV solutions. Furthermore, better oxygenation was obtained with the left-shifted HbVs.  相似文献   

2.
The oxygen transport capacity of phospholipid vesicles encapsulating purified Hb (HbV) produced with a Po(2) at which Hb is 50% saturated (P 50 ) of 8 (HbV(8)) and 29 mmHg (HbV(29)) was investigated in the hamster chamber window model by using microvascular measurements to determine oxygen delivery during extreme hemodilution. Two isovolemic hemodilution steps were performed with 5% recombinant albumin (rHSA) until Hct was 35% of baseline. Isovolemic exchange was continued using HbV suspended in rHSA solution to a total [Hb] of 5.7 g/dl in blood. P(50) was modified by coencapsulating pyridoxal 5'-phosphate. Final Hct was 11% for the HbV groups, with a plasma [Hb] of 2.1 +/- 0.1 g/dl after exchange with HbV(8) or HbV(29). A reference group was hemodiluted to Hct 11% with only rHSA. All groups showed stable blood pressure and heart rate. Arterial oxygen tensions were significantly higher than baseline for the HbV groups and the rHSA group and significantly lower for the HbV groups compared with the rHSA group. Blood pressure was significantly higher for the HbV(8) group compared with the HbV(29) group. Arteriolar and venular blood flows were significantly higher than baseline for the HbV groups. Microvascular oxygen delivery and extraction were similar for the HbV groups but lower for the rHSA group (P < 0.05). Venular and tissue Po(2) were statistically higher for the HbV(8) vs. the HbV(29) and rHSA groups (P < 0.05). Improved tissue Po(2) is obtained when red blood cells deliver oxygen in combination with a high- rather than low-affinity oxygen carrier.  相似文献   

3.
A phospholipid vesicle encapsulating hemoglobin (Hb vesicle, HbV) has been developed to provide O(2)-carrying capacity to plasma expanders. Its ability to restore systemic and microcirculatory conditions after hemorrhagic shock was evaluated in the dorsal skinfold window preparation of conscious hamsters. The HbV was suspended in 8% human serum albumin (HSA) at Hb concentrations of 3.8 g/dl [HbV(3.8)/HSA] and 7.6 g/dl [HbV(7.6)/HSA]. Shock was induced by 50% blood withdrawal, and mean arterial pressure (MAP) at 40 mmHg was maintained for 1 h by the additional blood withdrawal. The hamsters receiving either HbV(3.8)/HSA or HbV(7.6)/HSA suspensions restored MAP to 93 +/- 14 and 93 +/- 10 mmHg, respectively, similar with those receiving the shed blood (98 +/- 13 mmHg), which were significantly higher by comparison with resuscitation with HSA alone (62 +/- 12 mmHg). Only the HSA group tended to maintain hyperventilation and negative base excess after the resuscitation. Subcutaneous microvascular blood flow reduced to approximately 10-20% of baseline during shock, and reinfusion of shed blood restored blood flow to approximately 60-80% of baseline, an effect primarily due to the sustained constriction of small arteries A(0) (diameter 143 +/- 29 microm). The HbV(3.8)/HSA group had significantly better microvascular blood flow recovery and nonsignificantly better tissue oxygenation than of the HSA group. The recovery of base excess and improved tissue oxygenation appears to be primarily due to the increased oxygen-carrying capacity of HbV fluid resuscitation.  相似文献   

4.
The aim of this study was to test the influence of hemoglobin, encapsulated in phospholipid vesicles as an oxygen carrier, given in the course of isovolemic hemodilution to improve oxygenation in critically ischemic hamster flap tissue. Capillary hemodynamics and macromolecular leakage were investigated with intravital microscopy and analyzed off-line with the CapImage software. Partial tissue oxygen tension was measured with fluorescence quenching electrodes. The occurrence of apoptosis was assessed with the terminal deoxynucleotidyl transferase-mediated dUTP nick-end labeling assay. Vesicles with (HbV) or without (V) encapsulated Hb were suspended in 6% hydroxyethyl starch (HES) used for the 33% blood exchange. In the ischemic tissue, hemodilution led to an increase in functional capillary density by 31% for HES (P < 0.01 vs. other groups), 66% for V-HES, and 62% for HbV-HES (all P < 0.01 vs. control). Capillary diameters behaved inversely proportional to capillary microhemodynamics. The 20% increase in macromolecular leakage found over time in control animals was completely abolished in the vesicles groups (P < 0.01) but not with HES. Oxygen tension was improved from 10.7 to 16.0 mmHg after HbV-HES (P < 0.01 vs. baseline and other groups). Compared with the other groups, apoptosis was significantly reduced after HbV-HES (P < 0.01). We conclude that the encapsulation of Hb was essential to attenuate hypoxia and subsequent cell death in the critically ischemic tissue. However, the effect was partly attributed to the rheological changes exerted by the vesicles.  相似文献   

5.
A phospholipid vesicle encapsulating Hb [Hb vesicle (HbV)] has been developed as a transfusion alternative. One characteristic of HbV is that the O(2) affinity [Po(2) at which Hb is 50% saturated (P(50))] of Hb can be easily regulated by the amount of the coencapsulated allosteric effector pyridoxal 5'-phosphate. In this study, we prepared two HbVs with different P(50)s (8 and 29 mmHg, termed HbV(8) and HbV(29), respectively) and observed their O(2)-releasing behavior from an occluded arteriole in a hamster skinfold window model. Conscious hamsters received HbV(8) or HbV(29) at a dose rate of 7 ml/kg. In the microscopic view, an arteriole (diameter: 53.0 +/- 6.6 mum) was occluded transcutaneously by a glass pipette on a manipulator, and the reduction of the intra-arteriolar Po(2) 100 mum down from the occlusion was measured by the phosphorescence quenching of preinfused Pd-porphyrin. The baseline arteriolar Po(2) (50-52 mmHg) decreased to about 5 mmHg for all the groups. Occlusion after HbV(8) infusion showed a slightly slower rate of Po(2) reduction compared with that after HbV(29) infusion. The arteriolar O(2) content was calculated at each reducing Po(2) in combination with the O(2) equilibrium curves of HbVs, and it was clarified that HbV(8) showed a significantly slower rate of O(2) release compared with HbV(29) and was a primary source of O(2) (maximum fraction, 0.55) overwhelming red blood cells when the Po(2) was reduced (e.g., <10 mmHg) despite a small dosage of HbV. This result supports the possible utilization of Hb-based O(2) carriers with lower P(50) for oxygenation of ischemic tissues.  相似文献   

6.
Isovolemic hemodilution to 11% systemic hematocrit was performed in the hamster window chamber model using 6% dextran 70 kDa (Dx 70) and 5% human serum albumin (HSA). Systemic and microvascular effects of these solutions were compared with polyethylene glycol (PEG)-conjugated 5% albumin (MPA) and PEG-conjugated 4.2% Hb (MP4). These studies were performed for the purpose of comparing systemic and microvascular responses of PEG vs. non-PEG plasma expanders and similar oxygen-carrying vs. noncarrying blood replacement fluids. Mean arterial blood pressure was statistically significantly reduced for all groups compared with baseline (P < 0.05), HSA, MPA, and MP4 higher than Dx 70 (P < 0.05). MP4 and MPA had a significantly higher cardiac index than HSA and Dx 70, in addition to a positive base excess. Microvascular blood flow and capillary perfusion were significantly higher for the PEG compounds compared with HSA and Dx 70. Intravascular PO2 for MP4 and MPA was higher in arterioles (P < 0.05) compared with HSA and Dx 70, but there was no difference in either tissue or venular PO2 between groups. Total Hb in the MP4 group was 4.8 +/- 0.4 g/dl, whereas the remaining groups had a range of 3.6-3.8 g/dl. The hemodilution results showed that PEG compounds maintained microvascular conditions with lower concentrations than conventional plasma expanders. Furthermore, microvascular oxygen delivery and extraction in the window chamber tissue were significantly higher for the PEG compounds. MP4 was significantly higher than MPA (P < 0.05) and was not statistically different from baseline, an effect due to the additional oxygen release to the tissue by the Hb MP4.  相似文献   

7.
A surface-modified polyethylene glycol-conjugated human hemoglobin (MP4) and alpha alpha-cross-linked human hemoglobin (alpha alpha Hb) were used to restore oxygen carrying capacity in conditions of extreme hemodilution (hematocrit 11%) in the hamster window model preparation. Changes in microvascular function were analyzed in terms of effects on capillary pressure and functional capillary density (FCD). MP4, at 1.0 +/- 0.2 g/dl blood concentration, significantly lowered mean arterial pressure (MAP) below baseline (99.6 +/- 7.6 mmHg) to 82.4 +/- 6.9 mmHg (P < 0.05) and decreased of FCD to 70 +/- 9%. alpha alpha Hb caused a greater recovery in MAP to 94.4 +/- 6.2 mmHg and lowered FCD to 62 +/- 8%. However, differences between alpha alpha Hb and MP4 in FCD were not statistically significant. Capillary pressures were in the ranges of 17-21 mmHg for MP4 and 15-19 mmHg for alpha alpha Hb, with both significantly lower than baseline (P < 0.05). Pressure in 80-microm-diameter arterioles was significantly increased with alpha alpha Hb relative to MP4 (P < 0.05). These results were compared with previous findings on the relation between capillary pressure and FCD; they supported the concept of a relationship between FCD and capillary pressure. Measurement of changes in arteriolar diameter, microvascular blood flow, and FCD show that there was no statistical difference between using alpha alpha Hb and MP4 in extreme hemodilution. Microvascular resistance in arterioles with a diameter range of 70-80 microm showed an increase relative to control with alpha alpha Hb, whereas MP4 caused a decrease.  相似文献   

8.
Hemoglobin-vesicles (HbV) have been developed for use as artificial O(2) carriers in which a purified Hb solution is encapsulated within a phospholipid bilayer membrane. In this study, bovine Hb (BHb) was tested as a source of HbV instead of human Hb (HHb). We compared the preparation process and characteristics of BHbV with those of HHbV. The purification of BHb was effectively performed simply with an ultrafiltration system including a process for removing virus and scrapie reagent. The removal ratio of the phospholipid components of bovine red blood cells was over 99.99%, and the protein purity was over 99.9%. The deoxygenated and carbonylated BHb showed denaturation transition temperatures at 83 and 87 degrees C, respectively, which are higher than those of HHb (80 and 78 degrees C, respectively), and resistant to pasteurization (60 degrees C, 10 h). The purified BHb was concentrated to over 40 g/dl, and encapsulated in a phospholipid bilayer membrane to form BHbV with a diameter of about 280 nm. The O(2) affinity (P(50)) of the BHbV was regulated by coencapsulation of an appropriate amount of Cl(-) (as NaCl), which binds to BHb as an allosteric effector, in the range 16-28 Torr, comparable to human blood (P(50) = 28 Torr). This is quite simple in comparison with HHb which requires phosphate derivatives such as pyridoxal 5'-phosphate as a replacement for 2,3-diphoshoglyceric acid. The viscosity and colloid osmotic pressure of the BHbV when suspended in 5% human serum albumin are 3.5 cP and 20 Torr, respectively, comparable to those of human blood. In conclusion, BHb can be used as a source for the production of HbV, not only because of its abundance in the cattle industry, but also because of the physicochemical advantages of the purification process, thermal stability, and regulation of O(2) affinity in comparison with HHb.  相似文献   

9.
Hb-vesicles (HbV) are artificial oxygen carriers that encapsulate purified Hb solution (35 g/dl) in unilamellar phospholipid vesicles (liposomes). The dispersion stability of HbV is attained using surface-modification with polyethylene glycol (PEG), so that the deoxygenated HbV can be stored at room temperature for years. Moreover, the intravenously injected HbV does not induce aggregation when contacted with blood components. Animal experiments have verified the safety and efficacy of HbV as a transfusion alternative. One advantage of HbV is that the O(2) affinity (P(50)) of HbV can be regulated easily to that of RBC (28 torr) and to other values by manipulating the amount of the allosteric effectors, such as pyridoxal 5'-phosphate, coencapsulated in HbV. It is possible that HbV with a lower P(50) (higher O(2) affinity) would retain O(2) in the normal tissue while unloading O(2) to a targeted hypoxic tissue. Small HbV (250-280 nm diameter) is distributed homogeneously in the plasma phase, and HbV would transport oxygen through collateral arteries in the ischemic tissues. Results of in vitro and in vivo experiments of the domestic and international collaborations have confirmed the possibility of targeted O(2) delivery by HbV.  相似文献   

10.
Responses to exchange transfusion using red blood cells (RBCs) with normal and reduced flexibility were studied in the hamster window chamber model during acute moderate isovolemic hemodilution to determine the role of RBC membrane stiffness in microvascular perfusion and tissue oxygenation. Erythrocyte stiffness was increased by 30-min incubation in 0.02% glutaraldehyde solution, and unreacted glutaraldehyde was completely removed. Filtration pressure through 5-microm pore size filters was used to quantify stiffness of the RBCs. Anemic conditions were induced by two isovolemic hemodilution steps using 6% 70-kDa dextran to a hematocrit (Hct) of 18% (moderate hemodilution). The protocol continued with an exchange transfusion to reduce native RBCs to 75% of baseline (11% Hct) with either fresh RBCs (RBC group) or reduced-flexibility RBCs (GRBC group) suspended in 5% albumin at 18% Hct; a plasma expander (6% 70-kDa dextran; Dex70 group) was used as control. Systemic parameters, microvascular perfusion, capillary perfusion [functional capillary density (FCD)], and oxygen levels across the microvascular network were measured by noninvasive methods. RBC deformability for GRBCs was significantly decreased compared with RBCs and moderate hemodilution conditions. The GRBC group had a greater mean arterial blood pressure (MAP) than the RBC and Dex70 groups. FCD was substantially higher for RBC (0.81 +/- 0.07 of baseline) vs. GRBC (0.32 +/- 0.10 of baseline) and Dex70 (0.38 +/- 0.10 of baseline) groups. Microvascular tissue Po(2) was significantly lower for Dex70 and GRBC vs. RBC groups and the moderate hemodilution condition. Results were attributed to decreased oxygen uploading in the lungs and obstruction of tissue capillaries by rigidified RBCs, indicating that the effects impairing RBC flexibility are magnified at the microvascular level, where perfusion and oxygenation may define transfusion outcome.  相似文献   

11.
Responses to exchange transfusion with red blood cells (RBCs) containing methemoglobin (MetRBC) were studied in an acute isovolemic hemodiluted hamster window chamber model to determine whether oxygen content participates in the regulation of systemic and microvascular conditions during extreme hemodilution. Two isovolemic hemodilution steps were performed with 6% dextran 70 kDa (Dex70) until systemic hematocrit (Hct) was reduced to 18% (Level 2). A third-step hemodilution reduced the functional Hct to 75% of baseline by using either a plasma expander (Dex70) or blood adjusted to 18% Hct with all MetRBCs. In vivo functional capillary density (FCD), microvascular perfusion, and oxygen distribution in microvascular networks were measured by noninvasive methods. Methylene blue was administered intravenously to reduce methemoglobin (rRBC), which increased oxygen content with no change in Hct or viscosity from MetRBC. Final blood viscosities after the entire protocol were 2.1 cP for Dex70 and 2.8 cP for MetRBC (baseline, 4.2 cP). MetRBC had a greater mean arterial pressure (MAP) than did Dex70. FCD was substantially higher for MetRBC [82 (SD 6) of baseline] versus Dex70 [38 (SD 10) of baseline], and reduction of methemoglobin to oxyhemoglobin did not change FCD [84% (SD 5) of baseline]. P(O2) levels measured with palladium-meso-tetra(4-carboxyphenyl)porphyrin phosphorescence were significantly changed for Dex70 and MetRBC compared with Level 2 (Hct 18%). Reduction of methemoglobin to oxyhemoglobin partially restored P(O2) to Level 2. Wall shear rate and wall shear stress decreased in arterioles and venules for Dex70 and did not change for MetRBC or rRBC. Increased MAP and shear stress-mediated factors could be the possible mechanisms that improved perfusion flow and FCD after exchange for MetRBC. Thus the fall in systemic and microvascular conditions during extreme hemodilution with low-viscosity plasma expanders seems to be, in part, from the decrease in blood viscosity independent of the reduction in oxygen content.  相似文献   

12.
Hb-vesicles (HbV) are artificial oxygen carriers that encapsulate purified Hb solution (35 g/dl) in unilamellar phospholipid vesicles (liposomes). The dispersion stability of HbV is attained using surface-modification with polyethylene glycol (PEG), so that the deoxygenated HbV can be stored at room temperature for years. Moreover, the intravenously injected HbV does not induce aggregation when contacted with blood components. Animal experiments have verified the safety and efficacy of HbV as a transfusion alternative. One advantage of HbV is that the O2 affinity (P50) of HbV can be regulated easily to that of RBC (28 torr) and to other values by manipulating the amount of the allosteric effectors, such as pyridoxal 5′-phosphate, coencapsulated in HbV. It is possible that HbV with a lower P50 (higher O2 affinity) would retain O2 in the normal tissue while unloading O2 to a targeted hypoxic tissue. Small HbV (250–280 nm diameter) is distributed homogeneously in the plasma phase, and HbV would transport oxygen through collateral arteries in the ischemic tissues. Results of in vitro and in vivo experiments of the domestic and international collaborations have confirmed the possibility of targeted O2 delivery by HbV.  相似文献   

13.
O2-carrying fluids based on hemoglobin (Hb) are in various stages of clinical trials to determine their suitability as O2-carrying plasma expanders. Polymerized Hb solutions are characterized by their vasoactivity, low O2 affinity, oncotic effect, prolonged shelf life, and stability. Physiological responses to facilitated O2 transport after exchange transfusion with polymerized bovine Hb (PBH) were studied in the hamster window chamber model during acute moderate anemia to determine how PBH affects microvascular perfusion and tissue oxygenation. The anemic state [29% hematocrit (Hct)] was induced by hemodilution with a plasma expander (70 kDa dextran). After hemodilution, animals were randomly assigned to different exchange transfusion groups. Study groups were based on the concentration of PBH used, namely: PBH at 13 g Hb/dl [PBH13], PBH diluted to 8 (PBH8) or 4 (PBH4) g Hb/dl in albumin solution at matching colloidal osmotic pressure (COP), and no PBH (only albumin solution) at matching COP (PBH0). Measurement of systemic parameters, microvascular hemodynamics, capillary perfusion, and intravascular and tissue O2 levels was performed at 18% Hct. Restitution of O2-carrying capacity with PBH13 increased arterial pressure and triggered vasoconstriction, low perfusion, and high peripheral resistance. PBH4 and PBH0 exhibited lower arterial pressures compared with PBH13. Exchange transfused animals with PBH8 and PBH4 better maintained perfusion and functional capillary density than PBH13. Blood gas parameters and acid-base balance were recovered proportional to microvascular perfusion. Arterial O2 tensions were improved with PBH4 and PBH8 by preventing O2 precapillary release and increasing O2 reserve. Further studies to establish PBH optimal dosage, efficacy, safety, and its effect on outcome are indicated before Hb-based O2-carrying blood substitutes are implemented in routine practice.  相似文献   

14.
Blood losses are usually corrected initially by the restitution of volume with plasma expanders and subsequently by the restoration of oxygen-carrying capacity using either a blood transfusion or possibly, in the near future, oxygen-carrying plasma expanders. The present study was carried out to test the hypothesis that high-plasma viscosity hemodilution maintains perfused functional capillary density (FCD) by preserving capillary pressure. Microvascular pressure responses to extreme hemodilution with low- (LV) and high-viscosity (HV) plasma expanders and an exchange transfusion with a polymerized bovine cell-free Hb (PBH) solution were analyzed in the awake hamster window chamber model (n = 26). Systemic hematocrit was reduced from 50% to 11%. PBH produced a greater mean arterial blood pressure than the nonoxygen carriers. FCD was higher after a HV plasma expander (70 +/- 15%) vs. PBH (47 +/- 12%). Microvascular pressure spanning the capillary network was higher after a HV plasma expander (16-19 mmHg) compared with PBH (12-16 mmHg) and a LV plasma expander (11-14 mmHg) but lower than control (22-26 mmHg). FCD was found to be directly proportional to capillary pressure. The use of a HV plasma expander in extreme hemodilution maintained the number of perfused capillaries and tissue perfusion by comparison with a LV plasma expander due to increased mean arterial blood pressure and capillary pressure. The use of PBH increased mean arterial pressure but reduced capillary pressure due to vasoconstriction and did not maintain FCD.  相似文献   

15.
The hamster window chamber model was used to study systemic and microvascular hemodynamic responses to extreme hemodilution with low- and high-viscosity plasma expanders (LVPE and HVPE, respectively) to determine whether plasma viscosity is a factor in homeostasis during extreme anemic conditions. Moderated hemodilution was induced by two isovolemic steps performed with 6% 70-kDa dextran until systemic hematocrit (Hct) was reduced to 18% (level 2). In a third isovolemic step, hemodilution with LVPE (6% 70-kDa dextran, 2.8 cP) or HVPE (6% 500-kDa dextran, 5.9 cP) reduced Hct to 11%. Systemic parameters, cardiac output (CO), organ flow distribution, microhemodynamics, and functional capillary density, were measured after each exchange dilution. Fluorescent-labeled microspheres were used to measure organ (brain, heart, kidney, liver, lung, and spleen) and window chamber blood flow. Final blood and plasma viscosities after the entire protocol were 2.1 and 1.4 cP, respectively, for LVPE and 2.8 and 2.2 cP, respectively, for HVPE (baseline = 4.2 and 1.2 cP, respectively). HVPE significantly elevated mean arterial pressure and CO compared with LVPE but did not increase vascular resistance. Functional capillary density was significantly higher for HVPE [87% (SD 7) of baseline] than for LVPE [42% (SD 11) of baseline]. Increases in mean arterial blood pressure, CO, and shear stress-mediated factors could be responsible for maintaining organ and microvascular perfusion after exchange with HVPE compared with LVPE. Microhemodynamic data corresponded to microsphere-measured perfusion data in vital organs.  相似文献   

16.
Acute normovolemic hemodilution (ANH) is efficient in reducing allogenic blood transfusion needs during elective surgery. Tissue oxygenation is maintained by increased cardiac output and oxygen extraction and, presumably, a more homogeneous tissue perfusion. The aim of this study was to investigate blood flow distribution and oxygenation of skeletal muscle. ANH from hematocrit of 36 +/- 3 to 20 +/- 1% was performed in 22 splenectomized, anesthetized beagles (17 analyzed) ventilated with room air. Normovolemia was confirmed by measurement of blood volume. Distribution of perfusion within skeletal muscle was determined by using radioactive microspheres. Tissue oxygen partial pressure was assessed with a polarographic platinum surface electrode. Cardiac index (3.69 +/- 0.79 vs. 4.79 +/- 0.73 l. min-1. m-2) and muscle perfusion (4.07 +/- 0.44 vs. 5.18 +/- 0.36 ml. 100 g-1. min-1) were increased at hematocrit of 20%. Oxygen delivery to skeletal muscle was reduced to 74% of baseline values (0.64 +/- 0.06 vs. 0.48 +/- 0.03 ml O2. 100 g-1. min-1). Nevertheless, tissue PO2 was preserved (27.4 +/- 1.3 vs. 29.9 +/- 1. 4 Torr). Heterogeneity of muscle perfusion (relative dispersion) was reduced after ANH (20.0 +/- 2.2 vs. 13.9 +/- 1.5%). We conclude that a more homogeneous distribution of perfusion is one mechanism for the preservation of tissue oxygenation after moderate ANH, despite reduced oxygen delivery.  相似文献   

17.
We studied the effects of normovolemic hemodilution on tissue oxygen extraction capabilities in a canine model of endotoxic shock. Eighteen anesthetized and mechanically ventilated dogs underwent normovolemic hemodilution with 6% hydroxyethyl starch solution to reach hematocrit (Hct) levels around 40, 30, or 20% before the administration of 2 mg/kg of Escherichia coli endotoxin. Cardiac tamponade was then induced by repeated injections of normal saline into the pericardial sac to reduce cardiac output and study whole body oxygen extraction capabilities. Whole body critical oxygen delivery was lower in the Hct 20% and 30% groups (8.4 +/- 0.4 and 10.4 +/- 0.7 ml. kg(-1). min(-1), respectively) than in the Hct 40% group (12.8 +/- 0.8 ml. kg(-1). min(-1)) (both P < 0.005). The whole body critical oxygen extraction ratio was higher in the Hct 30% and 20% groups (49.1 +/- 8.2 and 55.2 +/- 4.6%, respectively) than in the Hct 40% group (37.1 +/- 4.4 %) (both P < 0.05). Liver critical oxygen extraction ratio was also higher in the Hct 30% and 20% groups than in the Hct 40% group. The arterial lactate concentrations and the gradient between ileum mucosal PCO(2) and arterial PCO(2) were lower in the Hct 20% and 30% groups than in the Hct 40% group. We conclude that, during an acute reduction in blood flow during endotoxic shock in dogs, normovolemic hemodilution is associated with improved tissue perfusion and increased oxygen extraction capabilities.  相似文献   

18.
Tsai AG  Intaglietta M 《Biorheology》2001,38(2-3):229-237
Hemorheological studies lead to the axiom that high plasma viscosity is detrimental and that it is beneficial to lower blood viscosity, a precept embodied in the practice of hemodilution, where improved perfusion is attributed to the lowering of blood viscosity. Hemodilution is limited by the transfusion trigger, hemoglobin content of blood of about 7-8 g/dl, which indicates when further volume replacements must restore oxygen carrying capacity with red blood cells (RBC). However, oxygen consumption and delivery are not compromised upon passing this landmark. The reduced blood viscosity does not transmit adequate pressure to the capillaries, causing functional capillary density (FCD) to decrease, jeopardizing organ function through the inadequate extraction of products of metabolism from the tissue by the capillaries. Studies in hemorrhagic shock show that survival is primarily determined by the maintenance of FCD and secondarily by tissue oxygenation. FCD is maintained as hematocrit is reduced beyond the transfusion trigger by increasing plasma viscosity, which transmits systemic pressure to the capillaries and induces vasodilatation through the increased shear stress dependent release of vasodilators. Consequently the transfusion trigger is also a "viscosity trigger" indicating when blood and plasma viscosity are too low. In this condition increasing plasma viscosity is beneficial and extends the transfusion trigger reducing the use of blood transfusions.  相似文献   

19.
A phospholipid vesicle that encapsulates a concentrated hemoglobin (Hb) solution and pyridoxal 5'-phosphate as an allosteric effector [Hb vesicle (HbV) diameter, 250 nm] has been developed to provide an O2 carrying ability to plasma expanders. The O2 release from flowing HbVs was examined using an O2-permeable, fluorinated ethylenepropylene copolymer tube (inner diameter, 28 microm) exposed to a deoxygenated environment. Measurement of O2 release was performed using an apparatus that consisted of an inverted microscope and a scanning-grating spectrophotometer with a photon-count detector, and the rate of O2 release was determined based on the visible absorption spectrum in the Q band of Hb. HbVs and fresh human red blood cells (RBCs) were mixed in various volume ratios at a Hb concentration of 10 g/dl in isotonic saline that contained 5 g/dl albumin, and the suspension was perfused at the centerline flow velocity of 1 mm/s through the narrow tube. The mixtures of acellular Hb solution and RBCs were also tested. Because HbVs were homogeneously dispersed in the albumin solution, increasing the volume of the HbV suspension resulted in a thicker marginal RBC-free layer. Irrespective of the mixing ratio, the rate of O2 release from the HbV/RBC mixtures was similar to that of RBCs alone. On the other hand, the addition of 50 vol% of acellular Hb solution to RBCs significantly enhanced the rate of deoxygenation. This outstanding difference in the rate of O2 release between the HbV suspension and the acellular Hb solution should mainly be due to the difference in the particle size (250 vs. 7 nm) that affects their diffusion for the facilitated O2 transport.  相似文献   

20.
Ferric methemoglobin is reduced to its ferrous form by photoirradiation either by direct photoexcitation of the heme portion to induce electron transfer from the surrounding media (Sakai at al. (2000) Biochemistry 39, 14595-14602) or by an indirect electron transfer from a photochemically reduced electron mediator such as flavin. In this research, we studied the mechanism and optimal condition that facilitates photoreduction of flavin mononucleotide (FMN) to FMNH(2) by irradiation of visible light, and the succeeding reduction of concentrated metHb in phospholipid vesicles to restore its O(2) binding ability. Visible light irradiation (435 nm) of a metHb solution containing FMN and an electron donor such as EDTA showed a significantly fast reduction to ferrous Hb with a quantum yield (Phi) of 0.17, that is higher than the method of direct photoexcitation of heme (Phi = 0.006). Electron transfer from a donor molecule to metHb via FMN was completed within 30 ns. Native-PAGE and IEF electrophoresis indicated no chemical modification of the surface of the reduced Hb. Coencapsulation of concentrated Hb solution (35 g/dL) and the FMN/EDTA system in vesicles covered with a phospholipid bilayer membrane (Hb-vesicles, HbV, diameter: 250 nm) facilitated the metHb photoreduction even under aerobic conditions, and the reduced HbV restored the reversible O(2) binding property. A concentrated HbV suspension ([Hb] = 8 g/dL) was sandwiched with two glass plates to form a liquid layer with the thickness of about 10 microm (close to capillary diameter in tissue, 5 microm), and visible light irradiation (221 mW/cm(2)) completed 100% metHb photoreduction within 20 s. The photoreduced FMNH(2) reacted with O(2) to produce H(2)O(2), which was detected by the fluorescence measurement of the reaction of H(2)O(2) and p-nitrophenylacetic acid. However, the amount of H(2)O(2) generated during the photoreduction of HbV was significantly reduced in comparison with the homogeneous Hb solution, indicating that the photoreduced FMNH(2) was effectively consumed during the metHb reduction in a highly concentrated condition inside the HbV nanoparticles.  相似文献   