首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BACKGROUND: Quantitative proteomics is an emerging field that encompasses multiplexed measurement of many known proteins in groups of experimental samples in order to identify differences between groups. Antibody arrays are a novel technology that is increasingly being used for quantitative proteomics studies due to highly multiplexed content, scalability, matrix flexibility and economy of sample consumption. Key applications of antibody arrays in quantitative proteomics studies are identification of novel diagnostic assays, biomarker discovery in trials of new drugs, and validation of qualitative proteomics discoveries. These applications require performance benchmarking, standardization and specification. RESULTS: Six dual-antibody, sandwich immunoassay arrays that measure 170 serum or plasma proteins were developed and experimental procedures refined in more than thirty quantitative proteomics studies. This report provides detailed information and specification for manufacture, qualification, assay automation, performance, assay validation and data processing for antibody arrays in large scale quantitative proteomics studies. CONCLUSION: The present report describes development of first generation standards for antibody arrays in quantitative proteomics. Specifically, it describes the requirements of a comprehensive validation program to identify and minimize antibody cross reaction under highly multiplexed conditions; provides the rationale for the application of standardized statistical approaches to manage the data output of highly replicated assays; defines design requirements for controls to normalize sample replicate measurements; emphasizes the importance of stringent quality control testing of reagents and antibody microarrays; recommends the use of real-time monitors to evaluate sensitivity, dynamic range and platform precision; and presents survey procedures to reveal the significance of biomarker findings.  相似文献   

2.
3.
4.
Antibodies have been the workhorse reagents of protein capture and quantification since their 1959 debut in the RIAs developed by Yalow and Berson. However, there are technical challenges to the use of antibodies in highly multiplexed arrays aimed at measuring hundreds or even thousands of proteins at one time. We describe here a recently developed class of synthetic protein‐binding reagents (slow off‐rate modified aptamer). We discuss the chemical makeup and protein binding specifications of slow off‐rate modified aptamer reagents, compare them to traditional aptamers and antibodies, briefly describe the novel proteomic assay that takes advantage of their unique properties, and provide several examples of their multiple applications to biomarker discovery and validation across a range of biomedical science questions.  相似文献   

5.
Microarray technology enables high-throughput testing of gene expression to investigate various neuroscience related questions. This in turn creates a demand for scalable methods to confirm microarray results and the opportunity to use this information to discover and test novel pathways and therapeutic applications. Discovery of new central nervous system (CNS) treatments requires a comprehensive understanding of multiple aspects including the biology of a target, the pathophysiology of a disease/disorder, and the selection of successful lead compounds as well as efficient biomarker and drug disposition strategies such as absorption (how a drug is absorbed), distribution (how a drug spreads through an organism), metabolism (chemical conversion of a drug, if any, and into which substances), and elimination (how is a drug eliminated) (ADME). Understanding of the toxicity is also of paramount importance. These approaches, in turn, require novel high-content integrative assay technologies that provide thorough information about changes in cell biology. To increase efficiency of profiling, characterization, and validation, we established a new screening strategy that combines high-content image-based testing on Array Scan (Cellomics) with a confocal system and the multiplexed TaqMan RT-PCR method for quantitative mRNA expression analysis. This approach could serve as an interface between high-throughput microarray testing and specific application of markers discovered in the course of a microarray experiment. Markers could pinpoint activation or inhibition of a molecular pathway related, for instance, to neuronal viability. We demonstrate the successful testing of the same cell population in an image-based translocational assay followed by poly(A) mRNA capture and multiplexed single tube RT-PCR. In addition, Ciphergen ProteinChip analysis can be performed on the supernatant, thus allowing significant complementarity in the data output and interpretation by also including the capture and initial analysis of proteins in the integrative approach presented. We have determined various conditions including the number of cells, RT and PCR optimization, which are necessary for successful detection and consequent assay integration. We also show the successful convergence of various different approaches and multiplexing of different targets within a single real-time PCR tube. This novel integrative technological approach has utility for CNS drug discovery, target and biomarker identification, selection and characterization as well as for the study of toxicity- and adverse event-associated molecular mechanisms.  相似文献   

6.
Accurate cancer biomarkers are needed for early detection, disease classification, prediction of therapeutic response and monitoring treatment. While there appears to be no shortage of candidate biomarker proteins, a major bottleneck in the biomarker pipeline continues to be their verification by enzyme linked immunosorbent assays. Multiple reaction monitoring (MRM), also known as selected reaction monitoring, is a targeted mass spectrometry approach to protein quantitation and is emerging to bridge the gap between biomarker discovery and clinical validation. Highly multiplexed MRM assays are readily configured and enable simultaneous verification of large numbers of candidates facilitating the development of biomarker panels which can increase specificity. This review focuses on recent applications of MRM to the analysis of plasma and serum from cancer patients for biomarker verification. The current status of this approach is discussed along with future directions for targeted mass spectrometry in clinical biomarker validation.  相似文献   

7.
Bioconjugated quantum dots (QDs) provide a new class of biological labels for evaluating biomolecular signatures (biomarkers) on intact cells and tissue specimens. In particular, the use of multicolor QD probes in immunohistochemistry is considered one of the most important and clinically relevant applications. At present, however, clinical applications of QD-based immunohistochemistry have achieved only limited success. A major bottleneck is the lack of robust protocols to define the key parameters and steps. Here, we describe our recent experience, preliminary results and detailed protocols for QD-antibody conjugation, tissue specimen preparation, multicolor QD staining, image processing and biomarker quantification. The results demonstrate that bioconjugated QDs can be used for multiplexed profiling of molecular biomarkers, and ultimately for correlation with disease progression and response to therapy. In general, QD bioconjugation is completed within 1 day, and multiplexed molecular profiling takes 1-3 days depending on the number of biomarkers and QD probes used.  相似文献   

8.
In the degradation of chlorophyll, chlorophyllase catalyzes the initial hydrolysis of the phytol moiety from the pigment. Since chlorophyll degradation is a defining feature of plant senescence, compounds inhibiting chlorophyllase activity may delay senescence, thereby improving shelf life and appearance of plant products. Here we describe the development of a 96-well plate-based purification and assay system for measuring chlorophyllase activity. Integrated lysis and immobilized metal affinity chromatography plates were used for purifying recombinant hexahistidine-tagged Triticum aestivum (wheat) chlorophyllase from Escherichia coli. Chlorophyllase assays using chlorophyll as a substrate showed that the immobilized fusion protein displayed kinetic parameters similar to those of recombinant enzyme purified by affinity chromatography; however, the need to extract reaction products from a multiwell plate limits the value of this assay for high-throughput screening applications. Replacing chlorophyll with p-nitrophenyl-ester substrates eliminates the extraction step and allows for continuous measurement of chlorophyllase activity in a multiwell plate format. Determination of steady state kinetic constants, pH rate profile, the inhibitory effects of metal ions and esterase inhibitors, and the effect of functional group-modifying reagents validated the utility of the plate-based system. The combined purification and assay system provides a convenient and rapid method for the assessment of chlorophyllase activity.  相似文献   

9.
Reported here is the development of a multiplexed mass spectrometric immunoassay (MSIA) for the detection of myocardial infarction (MI). The assay is the product of a study that systematically progresses from biomarker discovery--to identification and verification--to assay design, data analysis, and statistical challenge. During targeted population proteomics investigations, two novel biomarkers, serum amyloid A1alpha and S-sulfated transthyretin, were found to be responsive to MI. These putative markers were subsequently screened in larger cohorts of individuals to verify their responsiveness toward MI. Upon verification, a multiplexed assay was designed that was capable of simultaneously monitoring the new markers plus a previously established MI-marker (myoglobin). The multiplexed MSIA was applied to two 96-sample sets comprised of 48-MI/48-healthy and 19-MI/77-healthy, which served as training and case cohorts, respectively. Data evaluation using either preset reference levels or multivariate analysis exhibited sensitivities and specificities of >97%. These findings illustrate the importance of using systematic approaches in clinical proteomics to discover biomarkers and produce high-performance assays relevant to disease.  相似文献   

10.
Early detection of breast cancer reduces the suffering and cost to society associated with the disease. A sensitive assay to identify biomarkers that can accurately diagnose the onset of breast cancer using non-invasively collected clinical specimens is ideal for early detection. The earlier and more accurate the diagnostic biomarker can predict disease onset, the more valuable it becomes. Here, a brief review of existing and emerging approaches for breast cancer biomarker identification and analysis is presented. Those biomarkers found in biological fluids, blood in particular, apparently hold the best promise for fast development of screening assays. Autoantibodies and abnormal tumor-specific DNA methylation found in cell-free plasma DNA may provide the best opportunity for constructing multiplexed and highly redundant tests, which will be sufficiently specific and sensitive for early detection of breast cancer. It is expected that technologies developed for breast cancer detection will be useful for other types of cancer.  相似文献   

11.
The inability to quantify large numbers of proteins in tissues and biofluids with high precision, sensitivity, and throughput is a major bottleneck in biomarker studies. We previously demonstrated that coupling immunoaffinity enrichment using anti-peptide antibodies (SISCAPA) to multiple reaction monitoring mass spectrometry (MRM-MS) produces Immunoprecipitation MRM-MS (immuno-MRM-MS) assays that can be multiplexed to quantify proteins in plasma with high sensitivity, specificity, and precision. Here we report the first systematic evaluation of the interlaboratory performance of multiplexed (8-plex) immuno-MRM-MS in three independent labs. A staged study was carried out in which the effect of each processing and analysis step on assay coefficient of variance, limit of detection, limit of quantification, and recovery was evaluated. Limits of detection were at or below 1 ng/ml for the assayed proteins in 30 μl of plasma. Assay reproducibility was acceptable for verification studies, with median intra- and interlaboratory coefficients of variance above the limit of quantification of 11% and <14%, respectively, for the entire immuno-MRM-MS assay process, including enzymatic digestion of plasma. Trypsin digestion and its requisite sample handling contributed the most to assay variability and reduced the recovery of target peptides from digested proteins. Using a stable isotope-labeled protein as an internal standard instead of stable isotope-labeled peptides to account for losses in the digestion process nearly doubled assay accuracy for this while improving assay precision 5%. Our results demonstrate that multiplexed immuno-MRM-MS can be made reproducible across independent laboratories and has the potential to be adopted widely for assaying proteins in matrices as complex as plasma.  相似文献   

12.

Background

The interrogation of proteomes (“proteomics”) in a highly multiplexed and efficient manner remains a coveted and challenging goal in biology and medicine.

Methodology/Principal Findings

We present a new aptamer-based proteomic technology for biomarker discovery capable of simultaneously measuring thousands of proteins from small sample volumes (15 µL of serum or plasma). Our current assay measures 813 proteins with low limits of detection (1 pM median), 7 logs of overall dynamic range (∼100 fM–1 µM), and 5% median coefficient of variation. This technology is enabled by a new generation of aptamers that contain chemically modified nucleotides, which greatly expand the physicochemical diversity of the large randomized nucleic acid libraries from which the aptamers are selected. Proteins in complex matrices such as plasma are measured with a process that transforms a signature of protein concentrations into a corresponding signature of DNA aptamer concentrations, which is quantified on a DNA microarray. Our assay takes advantage of the dual nature of aptamers as both folded protein-binding entities with defined shapes and unique nucleotide sequences recognizable by specific hybridization probes. To demonstrate the utility of our proteomics biomarker discovery technology, we applied it to a clinical study of chronic kidney disease (CKD). We identified two well known CKD biomarkers as well as an additional 58 potential CKD biomarkers. These results demonstrate the potential utility of our technology to rapidly discover unique protein signatures characteristic of various disease states.

Conclusions/Significance

We describe a versatile and powerful tool that allows large-scale comparison of proteome profiles among discrete populations. This unbiased and highly multiplexed search engine will enable the discovery of novel biomarkers in a manner that is unencumbered by our incomplete knowledge of biology, thereby helping to advance the next generation of evidence-based medicine.  相似文献   

13.
MS‐based targeted proteomics is a relevant technology for sensitive and robust relative or absolute quantification of proteins biomarker candidates in complex human biofluids or tissue extracts. Performing a multiplex assay imposes time scheduling of peptide monitoring only around their expected retention time that needs to be defined with synthetic peptide. Time‐scheduled monitoring is clearly a constraint that precludes from straightforward assay transfer between biological matrices or distinct experimental setup. Any unexpected retention time (RT) shift challenges assay robustness and its implementation for large‐scale analysis. Recently, Scout‐multiple reaction monitoring that fully releases multiplexed targeted acquisition from RT scheduling by successively monitoring complex transition groups triggered with sentinel molecules called Scout has been introduced. It is herein documented how Peptide Selector database and tool streamlines the building of a multiplexed method thanks to RT indexation relative to Scout peptides. This case study deals with surrogate peptides of biomarker candidates related to drug‐induced liver and vascular injury, running such on‐line built method (eight Scouts triggering the monitoring of a total of 692 transitions) enables 100% recovery of a panel of 93 spiked‐in heavy labeled standards, despite significant RT shifts between serum, plasma, or urine. This result illustrates the simplicity of automatically building and deploying robust proteomics targeted assay.  相似文献   

14.
Sandwich enzyme-linked immunosorbent assay (ELISA) microarrays are emerging as a strong candidate platform for multiplex biomarker analysis because of the ELISA's ability to quantitatively measure rare proteins in complex biological fluids. Advantages of this platform are high-throughput potential, assay sensitivity and stringency, and the similarity to the standard ELISA test, which facilitates assay transfer from a research setting to a clinical laboratory. However, a major concern with the multiplexing of ELISAs is maintaining high assay specificity. In this study, we systematically determine the amount of assay interference and noise contributed by individual components of a multiplexed 24-assay system. We find that nonspecific reagent cross-reactivity problems are relatively rare. We did identify the presence of contaminant antigens in a "purified antigen". We tested the validated ELISA microarray chip using paired serum samples that had been collected from four women at a 6-month interval. This analysis demonstrated that protein levels typically vary much more between individuals than within an individual over time, a result which suggests that longitudinal studies may be useful in controlling for biomarker variability across a population. Overall, this research demonstrates the importance of a stringent screening protocol and the value of optimizing the antibody and antigen concentrations when designing chips for ELISA microarrays.  相似文献   

15.
Robust methods for highly parallel, quantitative analysis of cellular protein tyrosine kinase activities may provide tools critically needed to decipher oncogenic signaling, discover new targeted drugs, diagnose cancer and monitor patients. Here, we describe proof-of-principle for a novel protein kinase assay with the potential to help overcome these challenges. MALDI-TOF mass spectrometry provides an ideal tool for label-free multiplexed analysis of peptide phosphorylation, but is poorly matched to homogeneous assays and complex samples. Thus, we conjugated a common oligonucleotide tag to multiple peptide substrates, offering efficient capture from solution-phase kinase reactions by annealing to the complementary sequence tethered to PEG-passivated superparamagnetic microparticles. To enable reversible conjugation, we developed a novel bifunctional cross-linker allowing simple and efficient preparation of photocleavable peptide-oligonucleotide conjugates. After washing away contaminants and following photorelease, MALDI-TOF analysis yielded relative phosphorylation of each peptide with high sensitivity and specificity. Validating the hybridization-mediated multiplexed kinase assay, when three peptide substrate-oligonucleotide conjugates were mixed with the tyrosine kinase c-Abl and ATP, we readily observed their differential phosphorylation yet measured a common IC(50) for the Abl kinase inhibitor imatinib. This new assay enables analysis of protein kinase activities in a multiplexed format amenable to screening inhibitors against multiple kinases in parallel, an important capability for drug discovery and predictive diagnostics.  相似文献   

16.
The current sensitivity of standard fluorescence-based protein detection limits the use of protein arrays in research and clinical diagnosis. Here, we use functionalized, macromolecular single-walled carbon nanotubes (SWNTs) as multicolor Raman labels for highly sensitive, multiplexed protein detection in an arrayed format. Unlike fluorescence methods, Raman detection benefits from the sharp scattering peaks of SWNTs with minimal background interference, affording a high signal-to-noise ratio needed for ultra-sensitive detection. When combined with surface-enhanced Raman scattering substrates, the strong Raman intensity of SWNT tags affords protein detection sensitivity in sandwich assays down to 1 fM--a three-order-of-magnitude improvement over most reports of fluorescence-based detection. We use SWNT Raman tags to detect human autoantibodies against proteinase 3, a biomarker for the autoimmune disease Wegener's granulomatosis, diluted up to 10(7)-fold in 1% human serum. SWNT Raman tags are not subject to photobleaching or quenching. By conjugating different antibodies to pure (12)C and (13)C SWNT isotopes, we demonstrate multiplexed two-color SWNT Raman-based protein detection.  相似文献   

17.
Partyka K  Maupin KA  Brand RE  Haab BB 《Proteomics》2012,12(13):2212-2220
The CA 19-9 antigen is currently the best individual marker for the detection of pancreatic cancer. In order to optimize the CA 19-9 assay and to develop approaches to further improve cancer detection, it is important to understand the specificity differences between CA 19-9 antibodies and the consequential affect on biomarker performance. Antibody arrays enabled multiplexed comparisons between five different CA 19-9 antibodies used in the analysis of plasma samples from pancreatic cancer patients and controls. Major differences were observed between antibodies in their detection of particular patient samples. Glycan array analysis revealed that certain antibodies were highly specific for the canonical CA 19-9 epitope, sialyl-Lewis A, while others bound sialyl-Lewis A in addition to a related structure called sialyl-Lewis C and modification with Nue5Gc. In a much larger patient cohort, we confirmed the binding of sialyl-Lewis C glycan by one of the antibodies and showed that the broader specificity led to the detection of an increased number of cancer patients without increasing detection of pancreatitis patient samples. This work demonstrates that variation between antibody specificity for cancer-associated glycans can have significant implications for biomarker performance and highlights the value of characterizing and detecting the range of glycan structures that are elevated in cancer.  相似文献   

18.
In this study we demonstrate the use of a multiplexed MRM-based assay to distinguish among normal (NL) and iron-metabolism disorder mouse models, particularly, iron-deficiency anemia (IDA), inflammation (INFL), and inflammation and anemia (INFL+IDA). Our initial panel of potential biomarkers was based on the analysis of 14 proteins expressed by candidate genes involved in iron transport and metabolism. Based on this study, we were able to identify a panel of 8 biomarker proteins: apolipoprotein A4 (APO4), transferrin, transferrin receptor 1, ceruloplasmin, haptoglobin, lactoferrin, hemopexin, and matrix metalloproteinase-8 (MMP8) that clearly distinguish among the normal and disease models. Within this set of proteins, transferrin showed the best individual classification accuracy over all samples (72%) and within the NL group (94%). Compared to the best single-protein biomarker, transferrin, the use of the composite 8-protein biomarker panel improved the classification accuracy from 94% to 100% in the NL group, from 50% to 72% in the INFL group, from 66% to 96% in the IDA group, and from 79% to 83% in the INFL+IDA group. Based on these findings, validation of the utility of this potentially important biomarker panel in human samples in an effort to differentiate IDA, inflammation, and combinations thereof, is now warranted. This article is part of a Special Section entitled: Understanding genome regulation and genetic diversity by mass spectrometry.  相似文献   

19.
A problem inherent to the use of cellular assays for drug discovery is their sensitivity to cytotoxic compounds, which can result in false hits from certain compound screens. To alleviate the need to follow-up hits from a reporter assay with a separate cytotoxicity assay, the authors have developed a multiplexed assay that combines the readout of a beta-lactamase reporter with that of a homogeneous cytotoxicity indicator. Important aspects to the development of the multiplexed format are addressed, including results that demonstrate that the IC(50) values of 40 select compounds in a beta-lactamase reporter assay for nuclear factor kappa B and SIE pathway antagonists are not affected by the addition of the cytotoxicity indicator. To demonstrate the improvement in hit confirmation, the multiplexed assay was used to perform a small-library screen (7728 compounds) for serotonin 5HT1A receptor antagonists. Hits identified from analysis of the beta-lactamase reporter data alone were compared to those hits determined when the reporter and cytotoxicity data generated from the multiplexed assay were combined. Confirmation rates were determined from compound follow-up using dose-response analysis of the potential antagonist hits identified by the initial screen. In this representative screen, the multiplexed assay approach yielded a 19% reduction in the number of compounds flagged for follow-up, with a 37% decrease in the number of false hits, demonstrating that multiplexing a beta-lactamase reporter assay with a cytotoxicity readout is a highly effective strategy for reducing false hit rates in cell-based compound screening assays.  相似文献   

20.
We have developed a new method using the Qbead system for high-throughput genotyping of single nucleotide polymorphisms (SNPs). The Qbead system employs fluorescent Qdot semiconductor nanocrystals, also known as quantum dots, to encode microspheres that subsequently can be used as a platform for multiplexed assays. By combining mixtures of quantum dots with distinct emission wavelengths and intensities, unique spectral 'barcodes' are created that enable the high levels of multiplexing required for complex genetic analyses. Here, we applied the Qbead system to SNP genotyping by encoding microspheres conjugated to allele-specific oligonucleotides. After hybridization of oligonucleotides to amplicons produced by multiplexed PCR of genomic DNA, individual microspheres are analyzed by flow cytometry and each SNP is distinguished by its unique spectral barcode. Using 10 model SNPs, we validated the Qbead system as an accurate and reliable technique for multiplexed SNP genotyping. By modifying the types of probes conjugated to microspheres, the Qbead system can easily be adapted to other assay chemistries for SNP genotyping as well as to other applications such as analysis of gene expression and protein-protein interactions. With its capability for high-throughput automation, the Qbead system has the potential to be a robust and cost-effective platform for a number of applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号