首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and specific HPLC method has been developed for the assay of vigabatrin in human plasma and urine. The assay involves derivatization with 4-chloro-7-nitrobenzofurazan, solid-phase extraction on a silica column and isocratic reversed-phase chromatography with fluorescence detection. Aspartam was used as an internal standard. The assay was linear over the concentration range of 0.2–20.0 μg/ml for plasma and 1.0–15.0 μg/ml for urine with a lower limit of detection of 0.1 μg/ml using 0.1 ml of starting volume of the sample. Both the within-day and day-to-day reproducibilities and accuracies were less than 5.46% and 1.6%, respectively. After a single oral dose of 500 mg of vigabatrin, the plasma concentration and the cumulative urinary excretion of the drug were determined.  相似文献   

2.
Severe homocystinemia is frequently associated with vascular disease while the pathological consequences of moderate or slightly elevated plasma homocysteine are unknown. Cobalamin and folate deficiencies may result in an elevation of plasma homocysteine. A sensitive and reproducible assay for total plasma homocysteine has been developed. The essential steps in the assay include (i) conversion of homocysteine disulfides to free homocysteine with borohydride reduction; (ii) conjugation of homocysteine with monobromobimane; (iii) separation of homocysteine-bimane from other plasma thiol-bimane adducts by reverse-phase high-performance liquid chromatography; and (iv) detection and quantitation of homocysteine-bimane by fluorometry. The method has a sensitivity of 4.4 pmol of homocysteine and is highly reproducible (intra- and interassay coefficients of variation = 4.97 and 4.53%, respectively). The mean concentration of total plasma homocysteine in nonfasting adult males (n = 12) and females (n = 12) was 15.8 (range, 7.0-23.7) and 16.5 nmol/ml (range, 8.6-20.7), respectively. Markedly elevated levels of homocysteine were found in patients with cobalamin and folate deficiency. Total plasma homocysteine represents approximately 4% of borohydride-generated thiol reactivity in the plasma of normal individuals.  相似文献   

3.
4.
A high-performance liquid chromatographic method was developed for the determination of methylguanidine in biological fluids. Methylguanidine and the internal standard were isolated from plasma by cation-exchange solid-phase extraction prior to chromatographic analysis. Urine samples were diluted and injected directly onto the analytical column. Chromatographic separation was carried out on an Ultrasil cation-exchange column using a mixture of methanol and monochloroacetate (15/85, v/v) as the mobile phase. Postcolumn derivatization of methylguanidine was carried out using alkaline ninhydrin reagent and the resulting fluorescent product was detected on-line. The method was specific, sensitive, reproducible, and linear over a wide a range of concentrations. The lower limit of detection for methylguanidine in plasma and urine was 1 and 100 ng/ml, respectively. The method was successfully employed for quantification of the levels of methylguanidine in normal and uremic human subjects, normal dogs, and dogs with ischemic-induced acute or spontaneous chronic renal failure.  相似文献   

5.
6.
Physostigmine (PHY) is an anticholinergic drug used in the treatment of neuromuscular disorders and organophosphate poisoning. We described a sensitive, accurate, and reproducible method for PHY determination in biological materials. The method utilized a liquid/liquid, ion pair extraction, normal phase HPLC separation, and fluorometric quantitation at 240 nm excitation and 360 nm emission wavelength. We used neostigmine as a stabilizing agent to protect PHY from degradation and dimethylphysostigmine as an internal standard. The peak-height ratio vs concentration was linear over a working range from 0.50 to 25.0 ng/ml of PHY in plasma. Sensitivity of the method was 100 pg/ml of plasma which was the limit of quantitative detection under the experimental conditions used. Precision of the method was evaluated using plasma spiked with two concentrations of PHY: 1.0 and 10.0 ng/ml. Intra-day coefficient of variation (CV) ranged from 3.8 to 5.3%, and inter-day CV ranged from 1.8 to 3.6% for the two levels. The average recovery was 92%. We applied the method to examine the stability of PHY in plasma stored at -15 and -80 degrees C. The data indicated that PHY can be stored at either temperature for 9 weeks without undergoing significant alterations.  相似文献   

7.
An HPLC method was developed for the determination of formaldehyde in human blood plasma. The method was based on the determination of the fluorescent product of the chemical reaction between formaldehyde and ampicillin. A 0.2-ml aliquot of blood plasma was reacted directly with ampicillin under acidic and heating conditions. The reaction product was extracted from the matrix with diethyl ether and analyzed by reversed-phase HPLC with fluorescence detection. Recoveries of spiked formaldehyde at the low ppm (μg/ml) level were between 93% and 102% with relative standard deviations less than 8%. The limits of detection and quantitation of formaldehyde in blood plasma samples were 0.46 μg/ml and 0.87 μg/ml, respectively.  相似文献   

8.
A sensitive and specific HPLC method has been developed for the assay of amlodipine in human plasma. The assay involves derivatization with 4-chloro-7-nitrobenzofurazan (NBD-Cl), solid-phase extraction on a silica column and isocratic reversed-phase chromatography with fluorescence detection. Nortriptyline hydrochloride was used as an internal standard. The assay was linear over the concentration range of 0.25–18.00 ng/ml. Both of the within-day and day-to-day reproducibility and accuracy were less than 11.80% and 12.00%, respectively. The plasma profile following a single administration of 10 mg amlodipine to a healthy volunteer was presented.  相似文献   

9.
Dihydroergotamine, a 5-hydroxytryptamine antagonist, is used for the treatment of vascular headaches. A high-performance liquid chromatography assay with fluorescence detection is described for the determination of dihydroergotamine in plasma. The assay was validated over the concentration range 0.1–10 ng/ml plasma and applied to the analysis of plasma samples from subjects treated intramuscularly and intranasally with 2 mg of dihydroergotamine.  相似文献   

10.
An isocratic reversed-phase high-performance liquid chromatographic method for the determination of amidepin has been developed. The method is based on the extraction of alkaline plasma with diethyl ether—dichloromethane, and the injection into the Supelcosil LC-18 column of the evaporated and reconstituted organic phase. After separation, detection is carried out by a fluorescence detector (excitation at 195 nm with no filter). The limit of detection is 10 ng/ml of plasma. The mean coefficient of variation is 12%. The plasma levels after oral administration and after intravenous administration are shown.  相似文献   

11.
The influence of the pH of the mobile phase with some modifiers on the chromatographic behavior and fluorescence properties of closantel have been investigated. At acidic pH values (2–6), the benzamide moiety of the closantel forms a six-membered ring by hydrogen bonding and possesses a native fluorescence. Using the fluorescence emission of closantel at λex=335 nm, λem=510 nm, and pH 2.5 of the mobile phase, a linear calibration curve was estimated over a concentration range of about two orders of magnitude with a correlation coefficient larger than 0.992. The limit of the fluorescence detection was 10 μg/kg. This value was at least 10 times lower than that using UV detection. The method was applied to the determination of closantel in plasma and tissue samples, purified by a solid-phase extraction with C18 cartridges.  相似文献   

12.
A simple procedure for the determination of amphetamine in urine with minimal sample preparation is described. This method involves direct addition of human urine to an acetone-dansyl chloride solution for simultaneous deproteinization and fluorescence derivatization. The derivatized amphetamine is then measured by HPLC with fluorescence detection. It eliminates the extraction procedures often required by other HPLC or GC methods. The effects of pH, temperature and reaction time on the derivatization reaction were investigated. The stability of amphetamine-dansyl chloride in different storage conditions was examined. The detection limit and linearity associated with this assay are discussed.  相似文献   

13.
A high-performance liquid chromatographic method, using fluorescence detection, was developed for the determination of (+)-catechin in rabbit plasma. The procedure involved the precipitation of plasma protein using acetonitrile, followed by solid-phase adsorption onto alumina. After washing with water and methanol, the residue was vortex-mixed with perchloric acid solution to release the adsorbed (+)-catechin. Separation was performed on a reversed-phase column using an eluent consisting of phosphoric acid solution with 12% acetonitrile. The excitation and emission wavelengths were set at 280 and 310 nm, respectively. The retention times for (+)-catechin and the internal standard (deoxyhigenamine) were 6.87 and 8.47 min respectively, without any interference. Validations of accuracy and precision were satisfactory in both within- and between-run assays. All coefficients of variance were less than 6% and mean relative errors were within ± 3.75%. The average recovery was 73.77%. The limit of detection and quantitation were 1 ng and 0.02 μg/ml, respectively. Application of this method was successfully assessed by intravenous administration of a 15 mg/kg dose of (+)-catechin in rabbits. This new method provides a simple, specific and sensitive determination for (+)-catechin in rabbit plasma and is suitable for pharmacokinetic studies.  相似文献   

14.
A simple and sensitive HPLC method has been developed for the determination of marbofloxacin (MAR) in plasma. Sample preparations were carried out by adding phosphate buffer (pH 7.4, 0.1 M), followed by extraction with trichloromethane. MAR and the internal standard, enrofloxacin (ENR), were separated on a reversed-phase column and eluted with aqueous solution–acetonitrile (80:20). The fluorescence of the column effluent was monitored at λex=338 and λem=425 nm. The retention times were 2.20 and 3.30 min for MAR and ENR, respectively. The method was shown to be linear from 15 to 1500 ng/ml (r2=0.999). The detection limit was 15 ng/ml. Mean recovery was determined as 90% by the analysis of plasma standards containing 150, 750, and 1500 ng/ml. Inter- and intra-assay precisions were 3.3% and 2.7%, respectively.  相似文献   

15.
A new, selective and sensitive high-performance liquid chromatography (HPLC) method with fluorimetric detection was developed for the determination of tianeptine (TIA) in human plasma using solid phase extraction (SPE) procedures. The method is based on the derivatization of TIA with 4-chloro-7-nitrobenzofurazan (NBD-Cl) in borate buffer of pH 8.5 to yield a yellow, fluorescent product. The HPLC separation was achieved on a Phenomenex C(18) column (250 mm x 4.6 mm) using a mobile phase of acetonitrile-10mM orthophosphoric acid (pH 2.5) (77:23, v/v) solvent system at 1 mL/min flow rate. Gabapentin (GA) was used as the internal standard. The fluorometric detector was operated at 458 nm (excitation) and 520 nm (emission). The assay was linear over the concentration range of 5-300 ng/mL. The detection limit (LOD) was found to be 2 ng/mL. The mean recovery was determined to be 88.6%. The proposed method was applied for pharmacokinetic study of 12.5mg TIA in a healthy volunteer.  相似文献   

16.
MK-0476 (montelukast sodium) is a potent and selective cysteinyl leukotriene receptor antagonist that is being investigated in the treatment of asthma. A simple and sensitive method for the determination of MK-0476 in human plasma was developed using column-switching high-performance liquid chromatography (HPLC) with fluorescence detection. A plasma sample was injected directly onto the HPLC system consisting of a pre-column (Capcell pak MF) and an analytical column (Capcell pak C18) which were connected with a six-port switching valve. The column eluate was monitored with a fluorescence detector (excitation at 350 nm; emission at 400 nm). The calibration curve was linear in a concentration range of 1–500 ng ml−1 for MK-0476 in human plasma. The intra-day coefficients of variation of all concentrations within the range was less than 9.2%, and the intra-day accuracy values were between 97.2 and 114.6%. This method was used to measure the plasma concentration of MK-0476 following oral administration of the drug in humans.  相似文献   

17.
A highly sensitive and selective method for determining 8-oxoguanine in plasma and urine was developed by high-performance liquid chromatography with electrochemical detection. The compound was separated by gradient elution on a C18 reversed-phase column with a mobile phase of acetonitrile and 0.1 M sodium acetate, pH 5.2. 8-Hydroxy-2′-deoxyguanosine was used as internal standard. 8-Oxoguanine was detected electrochemically by setting the potential to +300 mV vs. Pd reference. The sensitivity of the assay was 22 ng/ml with a signal-to-noise ratio of 7:1. The within-day relative standard deviations for 8-oxoguanine quality control samples with concentrations of 3340, 1340 and 84 ng/ml were 3.6, 4.3 and 5.7% for plasma, and 4.1, 4.6 and 6.2% for urine, respectively. The day-to-day relative standard deviations for the same samples were 3.8, 6.8 and 7.1% for plasma, and 3.9, 7.0 and 7.9% for urine, respectively. The method is designed to study the pharmacokinetics and metabolic fate of O6-benzylguanine in a phase I clinical trial. Previously, O6-benzyl-8-oxoguanine was identified as the primary metabolite of O6-benzylguanine in humans. We now demonstrate that 8-oxoguanine is a further metabolite of O6-benzylguanine.  相似文献   

18.
A rapid, sensitive and selective high-performance liquid chromatographic (HPLC) assay was developed for the determination of cibenzoline (Cipralan TM) in human plasma and urine. The assay involves the extraction of the compound into benzene from plasma or urine buffered to pH 11 and HPLC analysis of the residue dissolved in acetonitrile---phosphate buffer (0.015 mol/1, pH 6.0) (80:20). A 10-μ ion-exchange (sulfonate) column was used with acetonitrile—phosphate buffer (0.015 mol/1, pH 6.0) (80:20) as the mobile phase. UV detection at 214 nm was used for quantitation with the di-p-methyl analogue of cibenzoline as the internal standard.The recovery of cibenzoline in the assay ranged from 60 to 70% and was validated in human plasma and urine in the concentration range of 10–1000 ng/ml and 50–5000 ng/ml, respectively. A normal-phase HPLC assay was developed for the determination of the imidazole metabolite of cibenzoline. The assays were applied to the determination of plasma and urine concentrations of cibenzoline and trace amounts of its imidazole metabolite following oral administration of cibenzoline succinate to two human subjects.  相似文献   

19.
A rapid, reliable and specific reversed-phase high-performance liquid chromatographic procedure is described for the determination of diphenylpyraline hydrochloride at nanogram concentrations in plasma and urine. After extraction of the drug with n-pentane-2-propanol (50:1) from alkalinized samples, the organic extract was evaporated to dryness, reconstituted with methanol and chromatographed using a 5-μm Asahipak ODP-50 C18 column with UV detection at 254 nm. The elution time for diphenylpyraline was 7.9 min. The overall recovery of diphenylpyraline from spiked plasma and urine samples at concentrations ranging from 53 to 740 ng/ml were 94.65% and 92.29%, respectively. Linearity and precision data for plasma and urine standards after extraction were acceptable. The limit of detection was 15 ng/ml for both plasma and urine samples at 0.002 AUFS.  相似文献   

20.
Decarboxylated arginine, agmatine, is a neurotransmitter candidate for imidazoline receptors. A method is described to measure agmatine in rat brain and human plasma by isocratic high-performance liquid chromatography (HPLC) with flourescence detection and o-phthalaldehyde derivatization. Quantitation is based on the method of additions of internal agmatine spikes. This assay has sensitivity in the low picomole range and a detection limitof 100 fmol. The correlation coefficient for the agmatine standard curve was 0.999±0.001 S.D., and intra- and inter-assay C.V.s were less than 8%. The accuracy of our isocratic method compared favorably with a gradient HPLC protocol, originally developed for bacterial agmatine, which we modified for use with tissues. Agmatine concentrations in rat brain were proportioned similarly to the regional distribution of imidazoline-1 receptors. These methods can be used as reliable research tools in various biological samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号