首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Non-steroidal anti-inflammatory drugs (NSAIDs) such as piroxicam and mefenamic acid are commonly prescribed to treat inflammation, pain and fever. Similarly acetylsalicylic acid is used to prevent strokes and heart attacks. A rapid and selective method was developed for the simultaneous assay of three NSAIDs and salicylic acid via HPLC with fluorescence detection. The separation was performed using a "dual-mode" gradient (acetonitrile-0.1% aqueous orthophosphoric acid) and the analysis was completed within 7 min using an ACE column C18, 5 microm, 150 mm x 4.6 mm. Naproxen was used as internal standard. The proposed method is simple, selective as well as with a good sensitivity reaching LOD lower than 2 pmol (0.05 microM) and was applied for quantitative analysis in pharmaceuticals and in human serum samples. The mean recovery was more than 95% and the within-day and between-days precisions were found to be satisfactory having RSD within the acceptable limits (<10%).  相似文献   

2.
The suitability of micellar electrokinetic capillary chromatography (MEKC) with laser-induced fluorescence (LIF) detection for the determination of pheomelanin in biological materials has been investigated. 5-Carboxyfluorescein succinimidyl ester was chosen as the labeling reagent to precapillary derivatize the two marker aminohydroxyphenylalanine (AHP) isomers produced after reductive hydrolysis of pheomelanin with hydriodic acid (HI). Various parameters affecting derivatization and separation were systematically studied. Under optimal conditions, the analytes could be separated within 18 min, and the relative standard deviations (R.S.D.) of migration time and corrected peak areas were less than 5.5%. Compared with the conventional high-performance liquid chromatography (HPLC) method with electrochemical detection, the 100-fold improvements in sensitivity were achieved by applying LIF detection. As a preliminary application, this method has been successfully applied to the determination of pheomelanin in two human melanoma cell cultures, black hair, melanoma tissue and urine samples of human melanoma patients with the spiked recoveries in the range of 88-96%.  相似文献   

3.
A new method of determining coenzyme Q10 in human plasma was developed based on column-switching high performance liquid chromatography (HPLC). CoQ10 was quantitatively extracted into 1-propanol with a fast one-step extraction procedure, after centrifugation, the supernatant was cleaned on an octadecyl-bonded silica column and then transferred to reversed-phase column by a column-switching valve. Determination of CoQ10 was performed on a reversed-phase analytical column with ultraviolet detection at 275 nm and the mobile phase containing 10% (v/v) isopropanol in methanol at a flow-rate of 1.5 ml/min. The sensitivity of this method allows the detection of 0.1 microg/ml CoQ10 in plasma (S/N=3). The linearity between the concentration and peak height is from 0.05 to 20 mg/l. The reproducibility (R.S.D.%) of the method is less than 2% (within day) and less than 3% (between day), the average recovery is 100.9 + 2.1%, it takes only 30 min to complete an analysis procedure, suitable for the determination of CoQ10 in human plasma especially for batch analysis in clinical laboratories. Finally, the method was applied to determine the plasma CoQ10 levels in healthy subjects, hyperthyroid and hypothyroid patients.  相似文献   

4.
A sensitive and selective method was developed for the simultaneous determination of chloroquine (CQ) and its desethylated metabolites monodesethylchloroquine (DCQ) and bisdesethylchloroquine (BDCQ) in human liver microsomes. Analytes were separated on a C1 column using methanol-water (70:30, v/v) and triethylamine (0.1% v/v) as the mobile phase. The fluorescence detector was set at 250 (excitation) and 380 nm (emission). Following protein precipitation with ice-cold acetonitrile, microsomal incubation supernatants were directly injected into the HPLC system. Typically, 200 μl of incubate were diluted with 200 μl of acetonitrile and 15 μl were injected. The limit of quantitation was 78 nM of CQ or metabolite. Intra-day variability averaged 2.9% for CQ, 1.5% for DCQ and 2.5% for BDCQ. Inter-day variability was 3.1% for CQ, 3.5% for DCQ and 3.7% for BDCQ. Mean accuracies were 100% for CQ and BDCQ and 102% for DCQ.  相似文献   

5.
A sensitive, specific and reproducible fluorescence high performance liquid chromatography (HPLC) assay has been developed for the separate or simultaneous measurement of AQ-13 (a candidate 4-aminoquinoline antimalarial), chloroquine (CQ), and their metabolites in whole blood. After liquid-solid extraction using commercially available extraction cartridges, these two aminoquinolines (AQs) and their metabolites were separated on C18 (Xterra RP18) columns using a mobile phase containing 60% borate buffer (20 mM, pH 9.0) and 40% acetonitrile with isocratic elution at a flow-rate of 1.0 ml/min. The assay uses a biologically inactive 8-chloro-4-aminoquinoline (AQ-18) as its internal standard (IS). There is a linear relationship between the concentrations of these AQs and the peak area ratio (ratio between the peak area of the AQ or metabolite and the peak area of the IS) on the chromatogram. Linear calibration curves with correlation coefficients > or = 0.997 (r2 > or = 0.995, p < 0.001) were obtained for AQ-13, CQ and their N-dealkylated metabolites. Reproducibility of the assay was excellent with coefficients of variation (CVs) < or = 3.8% for AQ-13 and its metabolites, and < or =2.5% for CQ and its metabolites. The sensitivity of the assay is 5 nM using 1.0 ml of blood and a 20 microl injection volume, and can be increased by using 5.0 ml of blood with an injection volume of 40 microl.  相似文献   

6.
Simultaneous detection of the fluoroquinolone antibiotics ciprofloxacin, enrofloxacin, ofloxacin, and norfloxacin in eggs by a combination of supercritical fluid extraction (SFE) and high pressure liquid chromatography (HPLC) was studied. Lipid matrices that have been considered to result in poor extraction and isolation of fluoroquinolones in eggs were removed first by SFE with supercritical CO(2) alone, and then the fluoroquinolones were extracted by SFE with supercritical CO(2) containing 20% (v/v) methanol for HPLC analysis. A time-course study of the extraction of lipid matrices of eggs suggested that the SFE method successfully removed the matrices within 20 min. When the fluoroquinolones added to control eggs were extracted by SFE, the extraction efficiency was similar to that by the solvent extraction method, giving the recovery percentages from 83 to 96% in a 40 min-extraction time. The fluoroquinolones extracted from eggs by SFE were analyzed simultaneously by HPLC equipped with a fluorescence detector with detection sensitivity at about 10 ppb for the detection limit. The standard calibration profiles of fluoroquinolones showed linear responses to HPLC, showing more than 0.995 for the mean r(2) value. This is the first report of the simultaneous measurement of fluoroquinolones in eggs by a combination of SFE and HPLC. Using the SFE method allowed us to avoid extensive sample preparation such as solvent extraction and chromatographic cleanup that are basically required in extraction of fluoroquinolones.  相似文献   

7.
A sensitive HPLC method for determination of bisphenol A (BPA) in plasma samples using 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl) as a fluorescence labeling reagent was developed. The fluorescence labeling reaction was completed within 10 min at room temperature. DIB-Cl reacts with the phenolic hydroxyl group of BPA in the presence of triethylamine (TEA). The DIB-Cl derivative of BPA (DIB-BPA) was separated within 30 min with an ODS column using acetonitrile–water (90:10, v/v) as the isocratic eluent. Calibration graphs were linear over the range of 1.0–100 ng/ml (r=0.999). The detection limit of DIB-BPA was 0.05 ng/ml (2.5 pg) at a signal-to-noise ratio of 3. The relative standard deviations (RSDs) of the method for between-run were 1.0–5.0%. The analytical recoveries of known amounts (1.0 and 100 ng/ml) of BPA-spiked rabbit plasma were around 95%.  相似文献   

8.
Simultaneous detection of the fluoroquinolone antibiotics ciprofloxacin, enrofloxacin, ofloxacin, and norfloxacin in eggs by a combination of supercritical fluid extraction (SFE) and high pressure liquid chromatography (HPLC) was studied. Lipid matrices that have been considered to result in poor extraction and isolation of fluoroquinolones in eggs were removed first by SFE with supercritical CO2 alone, and then the fluoroquinolones were extracted by SFE with supercritical CO2 containing 20% (v/v) methanol for HPLC analysis. A time-course study of the extraction of lipid matrices of eggs suggested that the SFE method successfully removed the matrices within 20 min. When the fluoroquinolones added to control eggs were extracted by SFE, the extraction efficiency was similar to that by the solvent extraction method, giving the recovery percentages from 83 to 96% in a 40 min-extraction time. The fluoroquinolones extracted from eggs by SFE were analyzed simultaneously by HPLC equipped with a fluorescence detector with detection sensitivity at about 10 ppb for the detection limit. The standard calibration profiles of fluoroquinolones showed linear responses to HPLC, showing more than 0.995 for the mean r 2 value. This is the first report of the simultaneous measurement of fluoroquinolones in eggs by a combination of SFE and HPLC. Using the SFE method allowed us to avoid extensive sample preparation such as solvent extraction and chromatographic cleanup that are basically required in extraction of fluoroquinolones.  相似文献   

9.
We have established a new HPLC method for derivatizing and quantifying glufosinate (GLUF) in human serum and urine using p-nitrobenzoyl chloride (PNBC). The p-nitrobenzoyl derivative of GLUF (PNB-GLUF) was produced quantitatively over 10 min at room temperature. PNB-GLUF possesses the property of ultraviolet (UV) light absorption with a lambda(max) of 272.8 nm, and was isolated from biological specimens by reversed-phase chromatography using Inertsil Ph-3. In experiments at a UV wavelength of 273 nm, GLUF has a quantitative detection limit of 0.005 microg/ml, and when it was added to both serum and urine to yield concentrations of 0.1-1000 microg/ml, its recovery rate was quite satisfactory: at least 93.8% in all cases. Further, the measured amounts of GLUF in 23 serum samples from patients intoxicated by ingestion of GLUF compared favorably with those obtained by fluorescence derivatization-HPLC using 9-fluorenylmethyl chloroformate (R=0.998). This technique of analysis is, in addition, applicable for Glyphosat, which possesses a chemical structure resembling that of GLUF, and it will be of great use in the determination of these two compounds.  相似文献   

10.
Monitoring in vivo oxidative stress implicates the evaluation of damage and defence parameters by well-established, validated methods. We report two optimized and validated HPLC methods for measurement of malondialdehyde (MDA) and fat-soluble vitamins in rat plasma. For the MDA method, optimization experiments of the thiobarbituric acid test resulted in the addition of 1% butylhydroxytoluene to the reaction mixture and in a heating time reduction to 40 min, ensuring inhibition of further lipid peroxidation during the test. Validation experiments showed good linearity, precision and recovery. The use of HPLC with coulometric array detection technology permits simultaneous and sensitive analysis of different fat-soluble vitamins and related compounds (tocopherols, retinoids, carotenoids and coenzyme Q10), which are identified by both retention time and electrochemical characteristics. Furthermore, this method is extended to the analysis of coenzyme Q9, the predominant homologue in rats. Validation experiments with rat plasma gave good results.  相似文献   

11.
A selective and sensitive high-performance liquid chromatography (HPLC) method with fluorescence derivatization for the assay of guanylate cyclase (GC) activity is described. GTP and cGMP, which are the substrate and the product of GC, respectively, and other guanine-containing compounds are selectively converted by the reaction with (3,4-dimethoxyphenyl)glyoxal to the fluorescent derivatives. The derivatives were separated by reversed-phase HPLC. The limit of detection at a signal-to-noise ratio of 3 for cGMP was 10 fmol on the column. The sensitivity of this method was less than that of the conventional radioisotopic method, but this method is simple and convenient. Human platelet GC activity was measured, and the effects of some compounds were investigated.  相似文献   

12.
A method is described for the quantitative determination of d- and L-lactate in 10 microl of rat serum, which includes fluorescence derivatization of D- and L-lactate with 4-(N, N-dimethylaminosulfonyl)-7-piperazino-2,1,3- benzoxadiazole (DBD-PZ) followed by O-acetylation. The derivatives are separated by HPLC on an octadecylsilica, and, via column switching, on a cellulose-type chiral column. Levulinic acid was used as the internal standard. The enantiomers of lactate were separated with the separation factor (alpha) of 1.27 and the resolution (Rs) of 2.72, while the linearity for the detection was over the range of 10 nmol/ml to 20 micromol/ml (r = 0.999). Interday precision values for D-lactate in rat serum were 5.8, 5.3, and 4.1% for 10, 100, and 1000 nmol/ml, and accuracy values were 109.6, 98.2, and 103.1%, respectively (n = 5). The reduction of d-lactate concentration in rat serum by fasting was observed with the method.  相似文献   

13.
Topiramate has no ultraviolet, visible or fluorescence absorption. Analysis of the drug in human serum has been reported by high performance liquid chromatography (HPLC) with either mass detector or fluorescence detection after precolumn derivatization using 9-fluorenylmethyl chloroformate as fluorescent labeling agent. This study was aimed to validate derivatization and analysis of topiramate in human serum with HPLC using UV detection. The drug was extracted from human serum by liquid-liquid extraction and subjected to derivatization with 9-fluorenylmethyl chloroformate. Analysis was performed on a phenyl column using of spectrophotometer detection operated at wavelength of 264 nm. A mixture of phosphate buffer (0.05M) containing triethylamine (1 ml/l, v/v; pH 2.3) and methanol (28:72, v/v) at a flow rate of 2.5 ml/min was used as mobile phase. No interference was found with endogenous substances. Validity of the method was studied and the method was precise and accurate with a linearity range from 40 ng/ml to 40 microg/ml. The limit of quantification was 40 ng/ml of serum. The correlation coefficient between HPLC methods using fluorescence and UV detections was studied and found to be 0.992.  相似文献   

14.
Two capillary electrophoresis methods have been developed for the direct determination of triamterene and its main metabolite hydroxytriamterene sulfate in human urine. Analytes were detected using conventional UV detection as well as laser-induced fluorescence (LIF) detection with an HeCd-laser operating at a wavelength of 325 nm. The results of both detection techniques were compared. Indeed, the limit of quantification was eightfold lower using LIF detection (50 ng/ml) in comparison to UV detection (400 ng/ml). As no interference due to endogenous urine compounds was observed, direct urine analysis was feasible. Analysis was very simple and fast-one run could be performed within less than 10 min (CE-UV method) and 2.5 min (CE-LIF method), respectively. Both assays were fully validated and applied to urine samples from a human volunteer. The results of the application of the CE-LIF method to human urine samples are presented in this publication.  相似文献   

15.
P O Okonkwo  E I Eta 《Life sciences》1988,42(5):539-545
Chloroquine (CQ) and metronidazole (MZ) were measured in human urine and plasma by HPLC with UV detection. This method was used to analyse plasma levels in 4 African volunteers after an oral dose of 1000 mg CQ and 750 mg MZ, in a European on weekly prophylaxis of 500 mg CQ, and on 50 hospital urine samples. In the Africans peak plasma levels were over 1 microgram/ml and peak time was 1 1/2-2 hr. In the European plasma levels ranged from 0.58 to 0.36 microgram/ml. Over 80% of the urine samples contained CQ, MZ or both. The assay system was found flexible and economical for the therapeutic monitoring of these two important tropical drugs.  相似文献   

16.
A new method was developed for determination of itopride in human serum by reversed phase high-performance liquid chromatography (HPLC) with fluorescence detection (excitation at 291 nm and emission at 342 nm). The method employed one-step extraction of itopride from serum matrix with a mixture of tert-butyl methyl ether and dichloromethane (70:30, v/v) using etoricoxib as an internal standard. Chromatographic separation was obtained within 12.0 min using a reverse phase YMC-Pack AM ODS column (250 mm x 4.6 mm, 5 microm) and an isocratic mobile phase constituting of a mixture of 0.05% tri-fluoro acetic acid in water and acetonitrile (75:25, v/v) flowing at a flow rate of 1.0 ml/min. The method was linear in the range of 14.0 ng/ml to 1000.0 ng/ml. The lower limit of quantitation (LLOQ) was 14.0 ng/ml. Average recovery of itopride and the internal standard from the biological matrix was more than 66.04 and 64.57%, respectively. The inter-day accuracy of the drug containing serum samples was more than 97.81% with a precision of 2.31-3.68%. The intra-day accuracy was 96.91% or more with a precision of 5.17-9.50%. Serum samples containing itopride were stable for 180.0 days at -70+/-5 degrees C and for 24.0 h at ambient temperature (25+/-5 degrees C). The method was successfully applied to the bioequivalence study of itopride in healthy, male human subjects.  相似文献   

17.
An isocratic high-performance liquid chromatography (HPLC) method was developed and validated to determine Aloe Emodin (AE) in mouse plasma. The analysis required 0.3 ml of plasma and involves extraction with dichloromethane. The HPLC separation was carried out on Symmetry Shield RP18, a mobile phase of methanol-water-acetic acid (65:35:0.2) and fluorescence detection at lambda(ex)=410 nm and lambda(em)=510 nm. The retention time of AE was 11.7 min. The assay was linear from 10 to 1,000 ng/ml (r2 > or = 0.999), showed intra- and inter-day precision within 7.8 and 4.7%, and accuracy of 87.3-105.7%. Detection limit (LOD) and quantification limit (LOQ) were 4.5 and 5 ng/ml, respectively. The method was applied to determine for the first time the pharmacokinetic of AE in mice.  相似文献   

18.
A simple restricted-access media (RAM) HPLC method for simultaneous determination of the lactone and carboxylate forms of 10-hydroxycamptothecin (HCPT) in human serum was established. Using a RAM Hisep analytical column, serum samples were directly injected into the HPLC system. The eluted peaks of two forms of HCPT were monitored with a fluorescence detector. The separation was completed in 17 min. The linear range was 20-1000 ng/ml, intra-day and inter-day variations being less than 5%. The kinetic equation was introduced according to the analytical results. The equation shows that the course of the HCPT lactone form converting to carboxylate form in human serum at 4 degrees C is a first-order kinetic course. The concentration of each form at the moment of sampling was calculated by extrapolation.  相似文献   

19.
A high-performance liquid chromatographic (HPLC) method for the determination of histamine in tissues, based on precolumn derivation with o-phthalaldehyde, is described. Trichloroacetic acid extracts of rat brain, but not of rat stomach or of rat peritoneal mast cells, had to be cleaned-up by a chromatographic step before HPLC. The extracts were allowed to react with o-phthalaldehyde at pH 12.5 and -20 degrees C for 12 h, followed by acidification to pH 2.0. HPLC was performed on a reverse-phase column with isocratic elution using sulfuric acid in methanol as solvent system. A fluorescence detection system was used; excitation was set at 353 nm and emission was read at 451 nm. One chromatographic run was completed in 20 min. The detection limit with the conventional procedure was 1.5 ng histamine per sample, with a scaled-down procedure it was 250 pg per sample. With extracts of rat gastric mucosa the within-run variation was 2.7% and the day-to-day variation 4.5%.  相似文献   

20.
A simple micellar liquid chromatographic (MLC) procedure is reported for the determination of several benzodiazepines in serum: bromazepam, diazepam, flunitrazepam, halazepam, medazepam, nitrazepam, oxazepam and tetrazepam. The optimization studies have been made in C(18) and C(8) columns, using solutions containing sodium dodecyl sulphate (SDS) modified with butanol or pentanol as mobile phases. The method proposed for the determination of the benzodiazepines uses a hybrid micellar mobile phase of 0.06 M SDS-5% butanol-0.01 M phosphate buffer (pH 7) at 25 degrees C, and UV detection (230 nm) in a C(18) column. The serum samples were injected directly, without any pretreatment, and eluted in less than 22 min, in accordance with their relative polarities, as indicated by their octanol-water partition coefficients. The limits of detection (ng ml(-1)) were within the ranges of 2-6 and 4-18 for aqueous and serum samples, respectively. Repeatability and intermediate precision were tested for three different concentrations of the drugs, and RSD (%) was below 10 for most of the assays. The MLC results were compared with those obtained from a conventional HPLC method using methanol-water 5:5 (v/v) which requires a previous extraction procedure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号