首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
The present paper introduces a highly sensitive and selective method for simultaneous quantification of 12 cytokinins(free form and their conjugates).The method includes a protocol of extraction with methanol/water/formic acid(1514/1,v/v/v)to the micro-scale samples,pre-purification with solid phase extraction(SPE)cartridges of the extracts,separation with a high performance liquid chromatography(HPLC)and detection by an electrospray ionization ion trap mass spectrometry(ESI-Ion trap-MS)system in a consecutive ion monitoring(CRM)mode at the three stage fragmentation of mass spectrometry(MS3).The lowest detection level of the cytokinins of the method reaches 0.1-2.0 pg with a very wide range of linear regression from 1-512 pg,at the coefficient factors of 0.98-0.99.The feasibility of this method has been proven in the application of the method to the analysis of the trace-amount contents of cytokinins in the micro-scale samples of various types of plant materials,such as aerial parts of rice and poplar leaves etc.12 endogenous cytokinins had been identified and quantified in the plant tissues,with an acceptable relatively higher recovery rate from 40% to 70%.  相似文献   

2.
The increasing use of advanced methods, such as mass spectrometry, for the determination of cytokinins has raised special requirements for the extraction and purification of this class of plant hormones. Extraction of Arabidopsis thaliana plants with three different solvents, [80% (v/v) MeOH, Bieleski's MCF-7, and modified Bieleski's] provided similar yields of most analyzed cytokinins determined by high-performance liquid chromatography-tandem mass spectrometry (HPLC/MS/MS). However, the extraction with a modified Bieleski's solvent (MeOH-HCO2H-H2O [15:1:4, v/v/v]) gave the highest responses of deuterated cytokinins (used as test compounds) in plant extracts as compared to the responses of pure deuterated standards (relative internal standard response, RISR). Purification of cytokinins using Oasis MCX sorbent with reversed-phase and cation-exchange characteristics, in comparison to the DEAE Sephadex RP-C18 method, provided higher levels of zeatin riboside monophosphate and similar levels of cytokinin bases, ribosides and glucosides. Using this method the content of UV-absorbing contaminates was decreased by about 90% and the RISR values of all tested cytokinin standards but riboside monophosphates were increased about two-fold. The former method provided preparations more suitable for HPLC/MS/MS analysis with respect to simplicity and sample purity.  相似文献   

3.
In this work, we developed a novel class-specific immunoaffinity column for the natural isoprenoid cytokinins (CTKs) by using trans-zeatin riboside as the hapten to generate a complete antigen. By combination with a mixed-mode solid phase extraction step for pre-cleanup and a high performance liquid chromatography-quadrupole-time of flight mass spectrometry for the quantification, an efficient analytical protocol was established which allowed simultaneous quantification of eight endogenous isoprenoid CTKs in Arabidopsis thaliana leaves with a wide linear range from 25 to 500pg/g fresh weight and a detection limit of 12.5pg/g fresh weight. The method will be very useful for comprehensive research on the networks of signaling interactions of the active phytohormones and their regulation of the plant functions.  相似文献   

4.
A new extraction method has been developed for the extraction of prostaglandin E(2) (PGE(2)) from human plasma of patients suffering chronic inflammatory disorders. The extraction solvents were optimised systematically and simultaneously by using a central composite design. The optimised method involves precipitation of the protein fraction, centrifugation, evaporation and dissolution of the supernatant in the mobile phase, screening to confirm the presence of the analyte, and quantification of the positive samples by liquid chromatography tandem ion-trap mass spectrometry. Tandem mass spectrometry in negative mode was performed by isolating and fragmenting the ion [PGE(2)-H](-) signal m/z 351. Identification and quantification was carried out by extracting the ion fragment chromatograms at 333, 315 and 271 m/z. The quantitative determination was linear for the low nanogram (1-50 ng/ml) and upper picogram (400-1000 pg/ml) range studied, using 15 and 0.5 ng/ml of internal standard, respectively. The lower limit of detection was 2.5 pg for an injection volume of 25 microl. The optimised extraction method showed high reproducibility (coefficients of variation<4%) and recovery values, estimated from standard addition experiments, ranging from 96 to 98%.  相似文献   

5.
A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed and validated for determination of ibutilide in human plasma. The analyte and internal standard sotalol were extracted from plasma samples by liquid-liquid extraction, and separated on a C(18) column, using acetonitrile-water-10% butylamine-10% acetic acid (80:20:0.07:0.06, v/v/v/v) as the mobile phase. Detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via TurboIonSpray ionization (ESI). Linear calibration curves were obtained in the concentration range of 20-10,000 pg/ml, with a lower limit of quantitation of 10 pg/ml. The intra- and inter-day precision values were below 8% and accuracy was within +/-3% at all three QC levels. The method was utilized to support clinical pharmacokinetic studies of ibutilide in healthy volunteers following intravenous administration.  相似文献   

6.
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the estimation of clonidine in human plasma. Clonidine was extracted from human plasma by using solid-phase extraction technique. Nizatidine was used as the internal standard. A Hypurity C18 (50 mm x 4.6 mm i.d., 5 microm particle size) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involves a rapid solid-phase extraction from plasma, simple isocratic chromatography conditions and mass spectrometric detection that enables detection up to picogram levels with a total run time of 3.0 min only. The method was validated over the range of 50-2500 pg/mL. The absolute recoveries for clonidine (71.86%) and IS (69.44%) achieved from spiked plasma samples were consistent and reproducible.  相似文献   

7.
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection (LC-MS/MS) was developed for the determination of a potent 5-HT(1B/1D) receptor agonist, rizatriptan in human plasma using granisetron as the internal standard. The analyte and internal standard were isolated from 100 microL plasma samples by liquid-liquid extraction (LLE) and chromatographed on a Lichrospher C18 column (4.6mm x 50mm, 5 microm) with a mobile phase consisting of acetonitrile-10mM aqueous ammonium acetate-acetic acid (50:50:0.5, v/v/v) pumped at 1.0 mL/min. The method had a chromatographic total run time of 2 min. A Varian 1200 L electrospray tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 270-->201 (rizatriptan) and 313.4-->138 (granisetron) used for quantitation. The assay was validated over the concentration range of 0.05-50 ng/mL and was found to have acceptable accuracy, precision, linearity, and selectivity. The mean extraction recovery from spiked plasma samples was above 98%. The intra-day accuracy of the assay was within 12% of nominal and intra-day precision was better than 13% C.V. Following a 10mg dose of the compound administered to human subjects, mean concentrations of rizatriptan ranged from 0.2 to 70.6 ng/mL in plasma samples collected up to 24h after dosing. Inter-day accuracy and precision results for quality control samples run over a 5-day period alongside clinical samples showed mean accuracies of within 12% of nominal and precision better than 9.5% C.V.  相似文献   

8.
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection was developed for the determination of lansoprazole in human plasma using omeprazole as the internal standard. The analyte and internal standard were extracted from the plasma samples by liquid-liquid extraction using diethyl-ether-dichloromethane (70:30; v/v) and chromatographed on a C(18) analytical column. The mobile phase consisted of acetonitrile-water (90:10; v/v)+10 mM formic acid. The method has a chromatographic total run time of 5 min and was linear within the range 2.5-2000 ng/ml. Detection was carried out on a Micromass triple quadrupole tandem mass spectrometer by Multiple Reaction Monitoring (MRM). The intra- and inter-run precision, calculated from quality control (QC) samples, was less than 3.4%. The accuracy as determined from QC samples was less than 9%. The method herein described was employed in a bioequivalence study of two capsule formulations of lansoprazole.  相似文献   

9.
Liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods were developed to simultaneously determine the concentrations of angiotensin (Ang) II, Ang 1-7, Ang III, and Ang IV in biological samples. The samples were extracted with C18 solid-phase extraction cartridges and separated by a reverse-phase C18 column using acetonitrile in water with 0.1% formic acid as a mobile phase. Ang peptides were ionized by electrospray and detected by triple quadrupole MS in the positive ion mode. (M+3H)(3+) and (M+2H)(2+) ions were chosen as the detected ions in the single ion recording (SIR) mode for LC-MS. The limits of detection (signal/noise [S/N]=3) using SIR are 1 pg for Ang IV and 5 pg for Ang 1-7, Ang III, and Ang II. Multiple reaction monitoring (MRM) mode was used for LC-MS/MS. The limits of detection (S/N =3) using MRM are 20 pg for Ang IV and 25 pg for Ang 1-7, Ang III, and Ang II. These methods were applied to analyze Ang peptides in bovine adrenal microvascular endothelial cells. The results show that Ang II is metabolized by endothelial cells to Ang 1-7, Ang III, and Ang IV, with Ang 1-7 being the major metabolite.  相似文献   

10.
A sensitive and specific method was developed and validated for the quantitation of quercetin in human plasma and urine. The application of liquid chromatography-tandem mass spectrometry (LC/MS/MS) with a TurboIonspray (TIS) interface in negative mode under multiple reactions monitoring was investigated. Chromatographic separation was achieved on a C12 column using a mobile phase of acetonitrile/water with 0.2% formic acid (pH 2.4) (40/60, v/v). The detection limit was 100 pg/ml and the lower limit of quantification was 500 pg/ml for plasma samples; the detection limit was 500 pg/ml and the lower limit of quantification was 1 ng/ml for urine samples. The calibration curve was linear from 1 to 800 ng/ml for plasma samples and was linear from 1 to 200 and 50 to 2000 ng/ml for urine samples. All the intra- and inter-day coefficients of variation were less than 11% and intra- and inter-day accuracies were within +/-15% of the known concentrations. This represents a LC/MS/MS assay with the sensitivity and specificity necessary to determine quercetin in human plasma and urine. This assay was used to determine both parent quercetin and the quercetin after enzymatic hydrolysis with beta-glucuronidase/sulfatase in human plasma and urine samples following the ingestion of quercetin 500 mg capsules.  相似文献   

11.
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection (LC-MS/MS) was developed for the determination of Verapamil in human plasma using Metoprolol as the internal standard. The analyte and internal standard were extracted from the plasma samples by liquid-liquid extraction and chromatographed on a C(8) analytical column. The mobile phase consisted of methanol-water (70:30; v/v)+12 mM formic acid. The method had a chromatographic total run time of 3.5 min and was linear within the range 1.00-500 ng/mL. Detection was carried out on a Micromass Quattro Ultima tandem mass spectrometer by multiple reaction monitoring (MRM). The intra-run imprecision was less than 5.1% calculated from the quality control (QC) samples, and 16.3% from the limit of quantification (LOQ). The accuracy determined from QC samples were between 92.9 and 103.1%, and 95.2 and 115.3% from LOQ. Concerning the inter-batch analysis, the imprecision was less than 5.8% and 17.3% from QC samples and LOQ, respectively. The accuracy varied between 98.2 and 100.8% from QC and it was 103.1% from LOQ. The protocol herein described was employed in a bioequivalence study of two tablet formulations of Verapamil.  相似文献   

12.
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection was developed for the determination of Lisinopril in human plasma using Enalaprilat as internal standard. The analyte and internal standard were extracted from the plasma samples by solid-phase extraction using Waters HLB Oasis SPE cartridges and chromatographed on a C8 analytical column. The mobile phase consisted of acetonitrile/water (60:40, v/v) + 20 mM acetic acid + 4.3 mM of triethylamine. The method had a chromatographic total run-time of 6.5 min and was linear within the range 2.00-200 ng/ml. Detection was carried out on a Micromass triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM). The precision (CV%) and accuracy, calculated from limit of quantification (LOQ) samples (n = 8), were 8.9 and 98.9%, respectively. The method herein described was employed in a bioequivalence study of two tablet formulations of Lisinopril 20mg.  相似文献   

13.
Morphine is present in varying amounts as an endogenous product in human urine. Derivatization of morphine contained in urine with dansyl chloride yields a known product, which can be quantified by liquid chromatography mass spectrometry with high selectivity and sensitivity. Urine samples of 51 healthy individuals were spiked with stable-isotope labeled morphine, hydrolyzed and subjected to solid phase extraction followed by derivatization of morphine with dansyl chloride. The dansyl derivatives of naturally occurring morphine and deuterated internal standard were then detected by liquid chromatography-triple quadrupole mass spectrometry. Using the [N-CD(3)]-labeled internal standard and solid-phase extraction, a limit of detection of 35 fmol/ml (10 pg/ml) and a limit of quantification of 87.5 fmol/ml (25 pg/ml) was determined for morphine in human urine. This new LC-MS/MS method allowed the detection of endogenous morphine in human urine of 51 volunteers with an average value of 156.4 fmol/ml (44.7 ng/ml).  相似文献   

14.
A highly sensitive and specific assay for the quantification of thromboxane B2 (TXB2)(1) in human urine is described. The method is based on the use of low-blank (1H less than or equal to 0.2%) tetradeuterated internal standard 2 (18, 18, 19, 19-2H4-thromboxane B2), whose chemical synthesis is reported. After purification and high-performance liquid chromatography (HPLC) samples are derivatized to give an open-chain derivative of thromboxane B2, the methoxime pentafluorobenzyl ester tris(trimethylsilyl) ether (TXB2-MO-PFB-TMS3), most suitable for negative ion chemical ionization mass spectrometry. In the selected ion monitoring mode limits of detection per injection for pure standards and biological samples of 10 pg and 30 pg, respectively, are established. Normal urinary excretion of 1 in humans is 37-112 ng/24 h (n = 12).  相似文献   

15.
Oxytocin (OT) is a neuropeptide with an extremely low endogenous level (low pg/ml) in human plasma. It is very challenging to develop a highly sensitive assay to measure endogenous OT, including radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA). Electrospray ionization (ESI) liquid chromatography–tandem mass spectrometry (LC–MS/MS) can provide high-throughput and selective methods for quantification of peptides in biological samples. A novel and highly sensitive two-dimensional LC–MS/MS (2D-LC–MS/MS) assay combining solid-phase extraction (SPE) has been developed and validated for the determination of endogenous OT in both human and rat plasma. The lower limit of quantification (LLOQ) was 1.00 pg/ml for human and 50.0 pg/ml for rat. Human plasma diluted with water (1:6, v/v) was successfully optimized as a surrogate matrix for human to prepare standard curves without endogenous interference. The extraction efficiency and absolute recovery were above 65.8% using the HLB SPE procedure, and matrix effects were lower than 12%. The method was validated in the range of 1.00–250 pg/ml for human plasma and 50.0–10,000 pg/ml for rat plasma with precision less than 12.7% and accuracy less than 7%.  相似文献   

16.
We have developed a gas chromatography–high resolution mass spectrometry method for measuring pyrethroid, organophosphorus, carbamate and fipronil pesticides and the synergist piperonyl butoxide in human plasma. Plasma samples were extracted using solid phase extraction and were then concentrated for injection and analysis using isotope dilution gas chromatography–high resolution mass spectrometry. The limits of detection ranged from 10 to 158 pg/mL with relative recoveries at concentrations near the LODs (e.g., 25 or 250 pg/mL) ranging from 87% to 156% (9 of the 16 compounds were within ±15% of 100%). The extraction recoveries ranged from 20% to 98% and the overall method relative standard deviations were typically less than 20% with some exceptions. Analytical characteristics were determined at 25, 250, and 1000 pg/mL.  相似文献   

17.
In this work, an automated screening method for the simultaneous identification and quantitation of 30 representative multiclass drugs (including opiates, cocaine and its main metabolite, cannabinoids, amphetamines and other stimulants in hair samples) has been developed using fast liquid-chromatography time-of-flight mass spectrometry (LC-TOFMS). The identification and quantitation of the drugs were carried out by liquid chromatography using a C(18) column (4.6×50 mm) with 1.8 μm particle size. Accurate mass measurements of ions of interest (typically [M+H](+)) by electrospray time-of-flight mass spectrometry in the positive ionization mode were used for unambiguous confirmation of the targeted species. Three sample preparation methodologies were evaluated: (a) direct methanolic extraction by sonication, (b) acidic extraction, and (c) alkaline digestion. Direct methanolic extraction showed better recoveries and cleaner extracts. The limits of detection obtained in hair matrix were as low as 5 pg mg(-1) for cocaine and cannabidiol, ranging from 5 to 75 pg mg(-1) for the studied species while the LOQ ranged from 15 to 250 pg mg(-1). The method has been applied to six hair samples from drug consumer volunteers, where the presence of at least one drug was confirmed by accurate mass measurements within 2 ppm (mass error) in most cases. The present study demonstrates the usefulness of LC-TOFMS for both screening and quantitation purposes in drug testing in hair. In addition, the possibility of non-target or a posteriori data analysis of samples or the extension of the procedure for testing for additional compounds offers interesting features for forensic analysis.  相似文献   

18.
A method for the detection of trehalose-6-phosphate (T6P) in tissue of the model plant Arabidopsis thaliana is presented. Liquid-liquid extraction (LLE) and mixed mode solid-phase extraction (SPE) were used for sample pretreatment followed by anion exchange chromatography (AEC) coupled with electrospray ionization mass spectrometry (MS) for highly selective quantitative analysis. LLE of plant material was performed with chloroform/acetonitrile/water (3:7:16, v/v/v) followed by SPE with Oasis MAX material, which significantly reduced the complexity of the extracts. On-line coupling of MS with gradient AEC using a sodium hydroxide eluent was accomplished with a postcolumn ion suppressor. The method allows specific quantification of T6P with good linearity for spiked plant extracts, from 80 nM to 1.3 μM (r2 > 0.98). The limit of detection in plant extracts was 40 nM. The recovery of the method was above 80% for relevant T6P levels. The method was applied to the determination of T6P in seedlings from four mutant A. thaliana lines (TRR1-4) resisting growth arrest caused by external supply of trehalose. Results reveal that T6P accumulation differed substantially in the four mutant lines and wild type (WT). It is concluded that the mutants circumvent the growth arrest observed in WT seedlings on 100 mM trehalose by different mechanisms.  相似文献   

19.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of beraprost, a stable, orally active prostacyclin analogue with vasodilatory, antiplatelet and cytoprotective effects. The analyte and internal standard, indomethacin, were extracted by solid-phase extraction using OASIS HLB cartridge. The chromatographic separation was performed on a C18 column with a mobile of 0.1% formic acid-methanol (30:70, v/v). The highest daughter ion of deprotonated analyte was quantitated in negative ionization by multiple reactions monitoring with a mass spectrometer. The mass transitions m/z 397>269 and m/z 356>312 were used to measure beraprost and internal standard, respectively. The assay exhibited a linear range from 0.02 to 2 ng/mL for beraprost in human plasma. The lower limit of quantitation was 20 pg/mL with a relative standard deviation of less than 20%. The method was validated with respect to linearity, sensitivity, specificity, recovery, accuracy and precision. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic study.  相似文献   

20.
A procedure is presented for the detection in human hair of forensically relevant benzodiazepines, i.e. nordiazepam, oxazepem, bromazepam, diazepam, lorazepam, flunitrazepam, alprazolam and triazolam. The method involves decontamination of hair with methylene chloride, pulverization in a ball mill, incubation of 50 mg powdered hair in Soerensen buffer (pH 7.6) in the presence of prazepam-d5 used as internal standard, liquid-liquid extraction with diethyl ether-chloroform (80:20, v/v) and gas chromatography-mass spectrometry using negative chemical ionization after derivatization with, N,O-bis(trimethylsilyl)trifluoroacetamide plus 1% trimethylchlorosilane. The limits of detection for all benzodiazepines ranged from 1 to 20 pg/mg using a 50-mg hair sample. Coefficients of variation and extraction recoveries, ranging from 7.4 to 25.4% and 47.6 to 90%, respectively, were found suitable for a screening procedure. One hundred and fifteen samples were submitted to this screening procedure, and specimens tested positive for nordiazepam (0.20-18.87 ng/mg, n = 42) and its major metabolite oxazepam (0.10-0.50 ng/mg, n = 14), flunitrazepam (19–148 pg/mg, n = 31), lorazepam (31–49 pg/mg, n = 4) and alprazolam (0.3-1.24 ng/mg, n = 2). Bromazepam, diazepam and triazolam were not detected.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号