首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 750 毫秒
1.
A preliminary clinical trial using state‐of‐the‐art multiphoton tomography (MPT) and optical coherence tomography (OCT) for three‐dimensional (3D) multimodal in vivo imaging of normal skin, nevi, scars and pathologic skin lesions has been conducted. MPT enabled visualization of sub‐cellular details with axial and transverse resolutions of <2 μm and <0.5 μm, respectively, from a volume of 0.35 × 0.35 × 0.2 mm3 at a frame rate of 0.14 Hz (512 × 512 pixels). State‐of‐the‐art OCT, operating at a center wavelength of 1300 nm, was capable of acquiring 3D images depicting the layered architecture of skin with axial and transverse resolutions ~8 μm and ~20 μm, respectively, from a volume of 7 × 3.5 × 1.5 mm3 at a frame rate of 46 Hz (1024 × 1024 pixels). This study demonstrates the clinical diagnostic potential of MPT/OCT for pre‐screening relatively large areas of skin using 3D OCT to identify suspicious regions at microscopic level and subsequently using high resolution MPT to obtain zoomed in, sub‐cellular level information of the respective regions (© 2013 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

2.
Two‐photon microscopy (2PM) is one of the most widely used tools for in vivo deep tissue imaging. However, the spatial resolution and penetration depth are still limited due to the strong scattering background. Here we demonstrate a two‐photon focal modulation microscopy. By utilizing the modulation and demodulation techniques, background rejection capability is enhanced, thus spatial resolution and imaging penetration depth are improved. Compared with 2PM, the transverse resolution is increased by 70%, while the axial resolution is increased to 2‐fold. Furthermore, when applied in conventional 2PM mode, it can achieve inertial‐free scanning in either transverse or axial direction with in principle unlimited scanning speed. Finally, we applied 2PFMM in thick scattering samples to further examine the imaging performance. The results show that the signal‐to‐background ratio of 2PFMM can be improved up to five times of 2PM at the depth of 500 μm. Fluorescent imaging in the mouse brain tissue. 3D Thy1‐GFP hippocampal neurons imaged by (A) 2PM compared with (B) 2PFMM; (C‐H) xy maximum‐intensity projection imaged by 2PM compared with 2PFMM. Scale bar 50 μm.   相似文献   

3.
The side lobes of Bessel beam will create significant out‐of‐focus background when scanned in light‐sheet fluorescence microscopy (LSFM), limiting the axial resolution of the imaging system. Here, we propose to overcome this issue by scanning the sample twice with zeroth‐order Bessel beam and another type of propagation‐invariant beam, complementary to the zeroth‐order Bessel beam, which greatly reduces the out‐of‐focus background created in the first scan. The axial resolution can be improved from 1.68 μm of the Bessel light‐sheet to 1.07 μm by subtraction of the two scanned images across a whole field‐of‐view of up to 300 μm × 200 μm × 200 μm. The optimization procedure to create the complementary beam is described in detail and it is experimentally generated with a spatial light modulator. The imaging performance is validated experimentally with fluorescent beads as well as eGFP‐labeled mouse brain neurons.   相似文献   

4.
Brain imaging is an important technique in cognitive neuroscience. In this article, we designed a stereotaxic‐apparatus‐compatible photoacoustic microscope for the studies of rat cortical hemodynamics. Compared with existing optical resolution photoacoustic microscopy (ORPAM) systems, the probe owns feature of fast, light and miniature. In this microscope, we integrated a miniaturized ultrasound transducer with a center frequency of 10 MHz to detect photoacoustic signals and a 2‐dimensional (2D) microelectromechanical system (MEMS) scanner to achieve raster scanning of the optical focus. Based on phantom evaluation, this imaging probe has a high lateral resolution of 3.8 μm and an effective imaging domain of 2 × 2 mm2. Different from conventional ORPAMs, combining with standard stereotaxic apparatus enables broad studies of rodent brains without any motion artifact. To show its capability, we successfully captured red blood cell flow in the capillary, monitored the vascular changes during bleeding and blood infusion and visualized cortical hemodynamics induced by middle cerebral artery occlusion.   相似文献   

5.
Needle placement is important for many clinical interventions, such as tissue biopsy, regional anesthesia and drug delivery. It is essential to visualize the spatial position of the needle and the target tissue during the interventions using appropriate imaging techniques. Based on the contrast of optical absorption, photoacoustic imaging is well suited for the guidance of interventional procedures. However, conventional photoacoustic imaging typically provides two‐dimensional (2D) slices of the region of interest and could only visualize the needle and the target when they are within the imaging plane of the probe at the same time. This requires great alignment skill and effort. To ease this problem, we developed a 3D interventional photoacoustic imaging technique by fast scanning a linear array ultrasound probe and stitching acquired image slices. in vivo sentinel lymph node biopsy experiment shows that the technique could precisely locate a needle and a sentinel lymph node in a tissue volume while a perfusion experiment demonstrates that the technique could visualize the 3D distribution of injected methylene blue dye underneath the skin at high temporal and spatial resolution. The proposed technique provides a practical way for photoacoustic image‐guided interventions.   相似文献   

6.
Endoscopic optical coherence tomography (OCT) is a noninvasive technology allowing for imaging of tissue microanatomies of luminal organs in real time. Conventional endoscopic OCT operates at 1300 nm wavelength region with a suboptimal axial resolution limited to 8‐20 μm. In this paper, we present the first ultrahigh‐resolution tethered OCT capsule operating at 800 nm and offering about 3‐ to 4‐fold improvement of axial resolution (plus enhanced imaging contrast). The capsule uses diffractive optics to manage chromatic aberration over a full ~200 nm spectral bandwidth centering around 830 nm, enabling to achieve super‐achromaticity and an axial resolution of ~2.6 μm in air. The performance of the OCT capsule is demonstrated by volumetric imaging of swine esophagus ex vivo and sheep esophagus in vivo, where fine anatomic structures including the sub‐epithelial layers are clearly identified. The ultrahigh resolution and excellent imaging contrast at 800 nm of the tethered capsule suggest the potential of the technology as an enabling tool for surveillance of early esophageal diseases on awake patients without the need for sedation.   相似文献   

7.
8.
Three‐photon microscopy excited at the 1700‐nm window (roughly covering 1600‐1840 nm) is especially suitable for deep‐brain imaging in living animals. To match the brain refractive index, D2O has been exclusively used as the immersion medium. However, the hygroscopic property of D2O leads to a decrease of transmittance of the excitation light and as a result a decrease in three‐photon signals over time. Solutions such as replacing D2O from time to time, wrapping both the objective lens and the immersion D2O, and sealing D2O with paraffin liquid have all been demonstrated, which add to the system complexity. Based on our recent characterization of immersion oils, we propose using silicone oil as a potential alternative to D2O for deep‐brain imaging. Excited at 1600 nm, our comparative deep‐brain imaging using both D2O and silicone oil immersion show that silicone oil immersion yields 17% higher three‐photon signal in third‐harmonic generation imaging within the white matter. Besides, silicone oil immersion also enables three‐photon fluorescence imaging of vasculature up to 1460 μm (mechanical depth) into the mouse brain in vivo acquired at 2 seconds/frame. Together with the nonhygroscopic physical property, silicone oil is promising for long‐span three‐photon brain imaging excited at the 1700‐nm window.   相似文献   

9.
A compact high‐speed full‐field optical coherence microscope has been developed for high‐resolution in vivo imaging of biological tissues. The interferometer, in the Linnik configuration, has a size of 11 × 11 × 5 cm3 and a weight of 210 g. Full‐field illumination with low‐coherence light is achieved with a high‐brightness broadband light‐emitting diode. High‐speed full‐field detection is achieved by using part of the image sensor of a high‐dynamic range CMOS camera. En face tomographic images are acquired at a rate of 50 Hz, with an integration time of 0.9 ms. The image spatial resolution is 0.9 μm × 1.2 μm (axial × transverse), over a field of view of 245 × 245 μm2. Images of human skin, revealing in‐depth cellular‐level structures, were obtained in vivo and in real‐time without the need for stabilization of the subject. The system can image larger fields, up to 1 × 1 mm2, but at a reduced depth.   相似文献   

10.
Morphological assessment and three‐dimensional reconstructions of internal structures of Plodia interpunctella Hübner during metamorphosis stages were experimentally demonstrated using optical coherence tomography (OCT) for the first time. The conventional, complex sectioning methods were significantly simplified owing to the non‐invasive three‐dimensional imaging capability of OCT. Further, this study demonstrates the use of OCT as a non‐invasive detection tool for in vivo morphological observation of metamorphosis stages to gain a better understanding about the growth of internal organs, which can be considered a useful discovery in the field of entomology. Thus, the metamorphosis stages starting from the larva, three pupa stages to the adult stage were periodically visualized to examine the development of internal organs at each specific stage. This study essentially offers real‐time morphological information by non‐destructive observation of the organism and can also be useful for the investigation of other agricultural pests.  相似文献   

11.
Visualizing fine neuronal structures deep inside strongly light‐scattering brain tissue remains a challenge in neuroscience. Recent nanoscopy techniques have reached the necessary resolution but often suffer from limited imaging depth, long imaging time or high light fluence requirements. Here, we present two‐photon super‐resolution patterned excitation reconstruction (2P‐SuPER) microscopy for 3‐dimensional imaging of dendritic spine dynamics at a maximum demonstrated imaging depth of 130 μm in living brain tissue with approximately 100 nm spatial resolution. We confirmed 2P‐SuPER resolution using fluorescence nanoparticle and quantum dot phantoms and imaged spiny neurons in acute brain slices. We induced hippocampal plasticity and showed that 2P‐SuPER can resolve increases in dendritic spine head sizes on CA1 pyramidal neurons following theta‐burst stimulation of Schaffer collateral axons. 2P‐SuPER further revealed nanoscopic increases in dendritic spine neck widths, a feature of synaptic plasticity that has not been thoroughly investigated due to the combined limit of resolution and penetration depth in existing imaging technologies.   相似文献   

12.
Photoacoustic microscopy (PAM) can be classified as optical resolution (OR)‐PAM and acoustic resolution (AR)‐PAM depending on the type of resolution achieved. Using microelectromechanical systems (MEMS) scanner, high‐speed OR‐PAM system was developed earlier. Depth of imaging limits the use of OR‐PAM technology for many preclinical and clinical imaging applications. Here, we demonstrate the use of a high‐speed MEMS scanner for AR‐PAM imaging. Lateral resolution of 84 μm and an axial resolution of 27 μm with ~2.7 mm imaging depth was achieved using a 50 MHz transducer‐based AR‐PAM system. Use of a higher frequency transducer at 75 MHz has further improved the resolution characteristics of the system with a reduction in imaging depth and a lateral resolution of 53 μm and an axial resolution of 18 μm with ~1.8 mm imaging depth was achieved. Using the two‐axis MEMS scanner a 2 × 2 .5 mm2 area was imaged in 3 seconds. The capability of achieving acoustic resolution images using the MEMS scanner makes it beneficial for the development of high‐speed miniaturized systems for deeper tissue imaging.   相似文献   

13.
Astrocytes play a key role in the central nervous system. However, methods of visualizing astrocytes in the deep brain in vivo have been lacking. 3‐photon fluorescence imaging of astrocytes labeled by sulforhodamine 101 (SR101) is demonstrated in deep mouse brain in vivo. Excitation wavelength selection was guided by wavelength‐dependent 3‐photon action cross section (ησ 3) measurement of SR101. 3‐photon fluorescence imaging of the SR101‐labeled vasculature enabled an imaging depth of 1340‐μm into the mouse brain. This justifies the deep imaging capability of the technique and indicates that the imaging depth is not determined by the signal‐to‐background ratio limit encountered in 2‐photon fluorescence imaging. Visualization of astrocytes 910 μm below the surface of the mouse brain in vivo is demonstrated, 30% deeper than that using 2‐photon fluorescence microscopy. Through quantitative comparison of the signal difference between the SR101‐labeled blood vessels and astrocytes, the challenges of visualizing astrocytes below the white matter is further elucidated.   相似文献   

14.
Dynamic intravital imaging is essential for revealing ongoing biological phenomena within living organisms and is influenced primarily by several factors: motion artifacts, optical properties and spatial resolution. Conventional imaging quality within a volume, however, is degraded by involuntary movements and trades off between the imaged volume, imaging speed and quality. To balance such trade‐offs incurred by two‐photon excitation microscopy during intravital imaging, we developed a unique combination of interlaced scanning and a simple image restoration algorithm based on biological signal sparsity and a graph Laplacian matrix. This method increases the scanning speed by a factor of four for a field size of 212 μm × 106 μm × 130 μm, and significantly improves the quality of four‐dimensional dynamic volumetric data by preventing irregular artifacts due to the movement observed with conventional methods. Our data suggest this method is robust enough to be applied to multiple types of soft tissue.  相似文献   

15.
Stereotactic biopsy is used to enable diagnostic confirmation of brain tumors and treatment planning. Despite being a well‐established technique, it is related to significant morbidity and mortality rates mostly caused by hemorrhages due to blood vessel ruptures. This paper presents a method of vessel detection during stereotactic biopsy that can be easily implemented by integrating two side‐view fibers into a conventional side‐cutting biopsy needle. Tissue within the needle window is illuminated through the first fiber; the second fiber detects the remitted light. By taking the ratio of the intensities at two wavelengths with strongly differing hemoglobin absorption, blood vessels can be recognized immediately before biopsy sampling. Via ray tracing simulations and phantom experiments, the dependency of the remission ratio R = I578/I650 on various parameters (blood oxygenation, fiber‐to‐vessel and inter‐fiber distance, vessel diameter and orientation) was investigated for a bare‐fiber probe. Up to 800–1200 µm away from the probe, a vessel can be recognized by a considerable reduction of the remission ratio from the background level. The technique was also successfully tested with a real biopsy needle probe on both optical phantoms and ex‐vivo porcine brain tissue, thus showing potential to improve the safety of stereotactic biopsy.

Dual‐wavelength remission measurement for the detection of blood vessels during stereotactic biopsy.  相似文献   


16.
Multiphoton action cross‐sections are the prerequisite for excitation light selection. At the 1700‐nm window suitable for deep‐tissue imaging, wavelength‐dependent 3‐photon action cross‐sections ησ3 for RFPs are unknown, preventing wavelength selection. Here we demonstrate: (1) ex vivo measurement of wavelength‐dependent ησ3 for purified RFPs; (2) a multiphoton imaging guided measurement system for in vivo measurement; and (3) in vivo measurement of wavelength‐dependent ησ3 in RFP labeled cells. These fundamental results will provide guidelines for excitation wavelength selection for 3‐photon fluorescence imaging of RFPs at the 1700‐nm window, and augment the existing database of multiphoton action cross‐sections for fluorophores.   相似文献   

17.
A two‐photon fluorescence lifetime (2P‐FLIM) microendoscope, capable of energetic metabolism imaging through the intracellular nicotinamide adenine dinucleotide (NADH) autofluorescence, at sub‐cellular resolution, is demonstrated. It exhibits readily usable characteristics such as convenient endoscope probe diameter (≈2 mm), fiber length (>5 m) and data accumulation rate (16 frames per second (fps)), leading to a FLIM refreshing rate of ≈0.1 to 1 fps depending on the sample. The spiral scanning image formation does not influence the instrument response function (IRF) characteristics of the system. Near table‐top microscope performances are achieved through a comprehensive system including a home‐designed spectro‐temporal pulse shaper and a custom air‐silica double‐clad photonic crystal fiber, which enables to reach up to 40 mW of ≈100 fs pulses @ 760 nm with a 80 MHz repetition rate. A GRadient INdex (GRIN) lens provides a lateral resolution of 0.67 μm at the focus of the fiber probe. Intracellular NADH fluorescence lifetime data are finally acquired on cultured cells at 16 fps.   相似文献   

18.
Optical coupling between a single, individually addressable neuron and a properly designed optical fiber is demonstrated. Two‐photon imaging is shown to enable a quantitative in situ analysis of such fiber–single‐neuron coupling in the live brain of transgenic mice. Fiber‐optic interrogation of single pyramidal neurons in mouse brain cortex is performed with the positioning of the fiber probe relative to the neuron accurately mapped by means of two‐photon imaging. These results pave the way for fiber‐optic interfaces to single neurons for a stimulation and interrogation of individually addressable brain cells in chronic in vivo studies on freely behaving transgenic animal models, as well as the integration of fiber‐optic single‐neuron stimulation into the optical imaging framework.

  相似文献   


19.
Imaging techniques are a cornerstone of contemporary biology. Over the last decades, advances in microscale imaging techniques have allowed fascinating new insights into cell and tissue morphology and internal anatomy of organisms across kingdoms. However, most studies so far provided snapshots of given reference taxa, describing organs and tissues under “idealized” conditions. Surprisingly, there is an almost complete lack of studies investigating how an organism′s internal morphology changes in response to environmental drivers. Consequently, ecology as a scientific discipline has so far almost neglected the possibilities arising from modern microscale imaging techniques. Here, we provide an overview of recent developments of X‐ray computed tomography as an affordable, simple method of high spatial resolution, allowing insights into three‐dimensional anatomy both in vivo and ex vivo. We review ecological studies using this technique to investigate the three‐dimensional internal structure of organisms. In addition, we provide practical comparisons between different preparation techniques for maximum contrast and tissue differentiation. In particular, we consider the novel modality of phase contrast by self‐interference of the X‐ray wave behind an object (i.e., phase contrast by free space propagation). Using the cricket Acheta domesticus (L.) as model organism, we found that the combination of FAE fixative and iodine staining provided the best results across different tissues. The drying technique also affected contrast and prevented artifacts in specific cases. Overall, we found that for the interests of ecological studies, X‐ray computed tomography is useful when the tissue or structure of interest has sufficient contrast that allows for an automatic or semiautomatic segmentation. In particular, we show that reconstruction schemes which exploit phase contrast can yield enhanced image quality. Combined with suitable specimen preparation and automated analysis, X‐ray CT can therefore become a promising quantitative 3D imaging technique to study organisms′ responses to environmental drivers, in both ecology and evolution.  相似文献   

20.
In natural tissues cells are embedded in a three‐dimensional fibrous network of biopolymers like collagen, hyaluronic acid etc. This extracellular matrix (ECM) influences the cell fate, the differentiation status, metabolic processes and provides structural integrity. For a three‐dimensional or physiological cell cultivation that are required in biomedical applications (e.g. tissue engineering, BioMEMS) scaffolds are needed. These scaffolds mimic the ECM according to their biocompatibility which comprises aspects of surface compatibility and importantly for tissue engineering applications aspects of structural compatibility. We have evaluated scaffold design parameters for the three‐dimensional cultivation of chondrocytes for the tissue engineering of artificial cartilage. Two‐photon polymerization is a powerful technique for fabrication of polymeric three‐dimensional micro‐ and submicro‐structures. The photoinitiation system for two‐photon polymerization is excited by simultaneous absorption of two photons leading to chemical polymerization reactions. Due to a tight confinement of the excitation volume around the focal point, this method can produce micrometer sized objects maintaining a high spatial resolution down to 100 nm. Two‐photon processes require very high photon densities which are provided by pulsed femtosecond lasers. The potential of this approach for microfabrication of scaffolds for tissue engineering is demonstrated by investigation of the cell response to microstructures with complex three‐dimensional geometry and feature sizes in the range of few micrometers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号