首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The nuclei of epithelial cells in stratified squamous epithelia have been reported to be either low scattering or high scattering. Using micro‐optical coherence tomography, we demonstrate that the nuclei are ‘low scattering’ in the core; those previously reported ‘high‐scattering’ signals are likely from the nucleocytoplasmic boundary. Further details can be found in the article by Si Chen, Xinyu Liu, Nanshuo Wang, et al. ( e201900073 ).

  相似文献   


2.
In this study, we developed a dual‐modality tomographic system that integrated photoacoustic imaging (PAI) and diffuse optical tomography (DOT) into a single platform for imaging human finger joints with fine structures and associated optical properties. In PAI, spherical focused transducers were utilized to collect acoustic signals, and the concept of virtual detector was applied in a conventional back‐projection algorithm to improve the image quality. A finite‐element based reconstruction algorithm was employed to quantitatively recover optical property distribution in the objects for DOT. The phantom results indicate that PAI has a maximum lateral resolution of 70 µm in resolving structures of targets. DOT was able to recover both optical absorption and reduced scattering coefficients of targets accurately. To validate the potential of this system in clinical diagnosis of joint diseases, the distal interphalangeal (DIP) joints of 4 healthy female volunteers were imaged. We successfully obtained high‐resolution images of the phalanx and the surrounding soft tissue via PAI, and recovered both optical absorption and reduced scattering coefficients of phalanx using DOT. The in vivo results suggest that this dual‐modality system has the potential for the early diagnosis of joint diseases such as osteoarthritis (OA) and rheumatoid arthritis (RA).

Integrated PAI/DOT imaging interface (top) and typical reconstruction of structures and associated optical properties of a female finger joint via PAI and DOT (bottom).  相似文献   


3.
4.
Photoacoustic imaging is a noninvasive imaging technique having the advantages of high‐optical contrast and good acoustic resolution at improved imaging depths. Light transport in biological tissues is mainly characterized by strong optical scattering and absorption. Photoacoustic microscopy is capable of achieving high‐resolution images at greater depth compared to conventional optical microscopy methods. In this work, we have developed a high‐resolution, acoustic resolution photoacoustic microscopy (AR‐PAM) system in the near infra‐red (NIR) window II (NIR‐II, eg, 1064 nm) for deep tissue imaging. Higher imaging depth is achieved as the tissue scattering at 1064 nm is lesser compared to visible or near infrared window‐I (NIR‐I). Our developed system can provide a lateral resolution of 130 μm, axial resolution of 57 μm, and image up to 11 mm deep in biological tissues. This 1064‐AR‐PAM system was used for imaging sentinel lymph node and the lymph vessel in rat. Urinary bladder of rat filled with black ink was also imaged to validate the feasibility of the developed system to study deeply seated organs.   相似文献   

5.
Non‐invasive biological imaging is crucial for understanding in vivo structure and function. Optical coherence tomography (OCT) and reflectance confocal microscopy are two of the most widely used optical modalities for exogenous contrast‐free, high‐resolution, three‐dimensional imaging in non‐fluorescent scattering tissues. However, sample motion remains a critical barrier to raster‐scanned acquisition and reconstruction of wide‐field anatomically accurate volumetric datasets. We introduce spectrally encoded coherence tomography and reflectometry (SECTR), a high‐speed, multimodality system for simultaneous OCT and spectrally encoded reflectance (SER) imaging. SECTR utilizes a robust system design consisting of shared optical relays, scanning mirrors, swept laser and digitizer to achieve the fastest reported in vivo multimodal imaging rate of 2 gigapixels per second. Our optical design and acquisition scheme enable spatiotemporally co‐registered acquisition of OCT cross‐sections simultaneously with en face SER images for multivolumetric mosaicking. Complementary axial and lateral translation and rotation are extracted from OCT and SER data, respectively, for full volumetric estimation of sample motion with micron spatial and millisecond temporal resolution.   相似文献   

6.
Osteocytes are the most abundant cells in bone and always the focus of bone research. They are embedded in the highly scattering mineralized bone matrix. Consequently, visualizing osteocytes deep in bone with subcellular resolution poses a major challenge for in vivo bone research. Here we overcome this challenge by demonstrating 3‐photon imaging of osteocytes through the intact mouse skull in vivo. Through broadband transmittance characterization, we establish that the excitation at the 1700‐nm window enables the highest optical transmittance through the skull. Using label‐free third‐harmonic generation (THG) imaging excited at this window, we visualize osteocytes through the whole 140‐μm mouse skull and 155 μm into the brain in vivo. By developing selective labeling technique for the interstitial space, we visualize the “sandwich” structure of osteocytes in their native environment. Our work provides novel imaging methodology for bone research in vivo.   相似文献   

7.
Fluorescence imaging in the second near‐infrared optical window (NIR‐II, 900‐1700 nm) has become a technique of choice for noninvasive in vivo imaging in recent years. Greater penetration depths with high spatial resolution and low background can be achieved with this NIR‐II window, owing to low autofluorescence within this optical range and reduced scattering of long wavelength photons. Here, we present a novel design of confocal laser scanning microscope tailored for imaging in the NIR‐II window. We showcase the outstanding penetration depth of our confocal setup with a series of imaging experiments. HeLa cells labeled with PbS quantum dots with a peak emission wavelength of 1276 nm can be visualized through a 3.5‐mm‐thick layer of scattering medium, which is a 0.8% Lipofundin solution. A commercially available organic dye IR‐1061 (emission peak at 1132 nm), in its native form, is used for the first time, as a NIR‐II fluorescence label in cellular imaging. Our confocal setup is capable of capturing optically sectioned images of IR‐1061 labeled chondrocytes in fixed animal cartilage at a depth up to 800 μm, with a superb spatial resolution of around 2 μm.   相似文献   

8.
In recent years, significant work has been devoted to the use of angle‐resolved elastic scattering for the extraction of nuclear morphology in tissue. By treating the nucleus as a Mie scattering object, techniques such as angle‐resolved low‐coherence interferometry (a/LCI) have demonstrated substantial success in identifying nuclear alterations associated with dysplasia. Because optical biopsies are inherently noninvasive, only a small, discretized portion of the 4π scattering field can be collected from tissue, limiting the amount of information available for diagnostic purposes. In this work, we comprehensively characterize the diagnostic impact of variations in angular sampling, range and noise for inverse light scattering analysis of nuclear morphology, using a previously reported dataset from 40 patients undergoing a/LCI optical biopsy for cervical dysplasia. The results from this analysis are applied to a benchtop scanning a/LCI system which compromises angular range for wide‐area scanning capability. This work will inform the design of next‐generation optical biopsy probes by directing optical design towards parameters which offer the most diagnostic utility.   相似文献   

9.
As a stimulating point in acupuncture, acupoint has unique microcirculatory features, and its dynamics vary greatly depending on health status. Acupoint sensitization is defined as the transformation of an acupoint from a “silenced status” (healthy) to an “activated status” (disease). Our previous study demonstrated that acupoint sensitization is associated with an increase in the level of local blood perfusion. However, the structural changes in microcirculation during acupoint sensitization have yet to be elucidated because the high‐resolution microcirculation imaging of acupoints has been difficult to obtain. In this study, the structural changes in microcirculation at the Zusanli (ST36), Yanglingquan (GB34) and nonacupoint sites on days 0, 7 and 21 were dynamically observed during acupoint sensitization in an experimental knee osteoarthritis mouse model by using optical‐resolution photoacoustic microscopy. The results showed that no significant differences in microvessel density, the distribution of vessel diameters or vascular tortuosity were observed at the GB34, ST36 or nonacupoint sites among days 0, 7 and 21. We proposed that acupoint sensitization may not be associated with the structural changes in microcirculation and that the microcirculatory changes during acupoint sensitization are more likely to be functional. The functional characteristics of the sensitized acupoints warrant further investigation.   相似文献   

10.
Adaptive optics has been widely used in the optical microscopy to recover high‐resolution images deep into the sample. However, the corrected field of view (FOV) with a single correction is generally limited, which seriously restricts the imaging speed. In this article, we demonstrate a high‐speed wavefront correction method by using the conjugate adaptive optical correction with multiple guide stars (CAOMG) based on the coherent optical adaptive technique. The results show that the CAOMG method can greatly improve the corrected FOV. For 120‐μm‐thick mouse brain tissue, the corrected FOV can be improved up to ~243 times of the conventional pupil adaptive optics (PAO) without additional time consumption. Therefore, this study shows the potential of high‐speed imaging through scattering medium in biological science.   相似文献   

11.
Our ability to detect neoplastic changes in gastrointestinal (GI) tracts is limited by the lack of an endomicroscopic imaging tool that provides cellular‐level structural details of GI mucosa over a large tissue area. In this article, we report a fiber‐optic‐based micro‐optical coherence tomography (μOCT) system and demonstrate its capability to acquire cellular‐level details of GI tissue through circumferential scanning. The system achieves an axial resolution of 2.48 μm in air and a transverse resolution of 4.8 μm with a depth‐of‐focus (DOF) of ~150 μm. To mitigate the issue of limited DOF, we used a rigid sheath to maintain a circular lumen and center the distal‐end optics. The sensitivity is tested to be 98.8 dB with an illumination power of 15.6 mW on the sample. With fresh swine colon tissues imaged ex vivo, detailed structures such as crypt lumens and goblet cells can be clearly resolved, demonstrating that this fiber‐optic μOCT system is capable of visualizing cellular‐level morphological features. We also demonstrate that time‐lapsed frame averaging and imaging speckle reduction are essential for clearly visualizing cellular‐level details. Further development of a clinically viable μOCT endomicroscope is likely to improve the diagnostic outcome of GI cancers.   相似文献   

12.
Despite the great promise behind the recent introduction of optoacoustic technology into the arsenal of small‐animal neuroimaging methods, a variety of acoustic and light‐related effects introduced by adult murine skull severely compromise the performance of optoacoustics in transcranial imaging. As a result, high‐resolution noninvasive optoacoustic microscopy studies are still limited to a thin layer of pial microvasculature, which can be effectively resolved by tight focusing of the excitation light. We examined a range of distortions introduced by an adult murine skull in transcranial optoacoustic imaging under both acoustically‐ and optically‐determined resolution scenarios. It is shown that strong low‐pass filtering characteristics of the skull may significantly deteriorate the achievable spatial resolution in deep brain imaging where no light focusing is possible. While only brain vasculature with a diameter larger than 60 µm was effectively resolved via transcranial measurements with acoustic resolution, significant improvements are seen through cranial windows and thinned skull experiments.

(a) Experimental setup for hybrid acoustic and optical resolution optoacoustic microscopy. (b) Transcranial scan of an adult mouse brain using the optical resolution mode. Scale bar is 375 µm.  相似文献   


13.
We report the enhancement in imaging performance of a spectral‐domain optical coherence microscope (OCM) in turbid media by incorporating an optical parametric amplifier (OPA). The OPA provides a high level of optical gain to the sample arm, thereby improving the signal‐to‐noise ratio of the OCM by a factor of up to 15 dB. A unique nonlinear confocal gate is automatically formed in the OPA, which enables selective amplification of singly scattered (ballistic) photons against the multiply‐scattered light background. Simultaneous enhancement in both imaging depth and spatial resolution in imaging microstructures in highly light‐scattering media are demonstrated with the combined OPA‐OCM setup.

Typical OCM inteferograms (left) and images (right) without and with OPA.  相似文献   


14.
15.
In the last years bioresorbable materials are gaining increasing interest for building implantable optical components for medical devices. In this work we show the fabrication of bioresorbable optical fibers designed for diffuse optics applications, featuring large core diameter (up to 200 μm) and numerical aperture (0.17) to maximize the collection efficiency of diffused light. We demonstrate the suitability of bioresorbable fibers for time‐domain diffuse optical spectroscopy firstly checking the intrinsic performances of the setup by acquiring the instrument response function. We then validate on phantoms the use of bioresorbable fibers by applying the MEDPHOT protocol to assess the performance of the system in measuring optical properties (namely, absorption and scattering coefficients) of homogeneous media. Further, we show an ex‐vivo validation on a chicken breast by measuring the absorption and scattering spectra in the 500–1100 nm range using interstitially inserted bioresorbable fibers. This work represents a step toward a new way to look inside the body using optical fibers that can be implanted in patients. These fibers could be useful either for diagnostic (e. g. for monitoring the evolution after surgical interventions) or treatment (e. g. photodynamic therapy) purposes. Picture : Microscopy image of the 100 μm core bioresorbable fiber.

  相似文献   


16.
Optical properties (μa, μs and g) of certain human tissue types such as skin and blood have been very well investigated. However until today, for internal body organs such as the esophagus they are not well characterized. For ex‐vivo measurements “Inverse Adding Doubling” (IAD) and Inverse Monte‐Carlo‐Simulation (IMCS) are state of the art. Both methods need the measurement of the collimated transmission. Current methods lack a proper way of measuring the collimated transmission. Hence, this measurement of the g‐factor has a systematic error. Therefore, for the measurement of the collimated transmission, a new approach has been developed and evaluated with intralipid. Finally, the optical properties of mucosa, sub mucosa, muscularis and adventitia of pig esophagus tissue are calculated with IAD. The results are promising and in agreement with published literature.

  相似文献   


17.
In this report, we describe the localization of diacylglycerol lipase‐α (DAGLα) in nuclei from adult cortical neurons, as assessed by double‐immunofluorescence staining of rat brain cortical sections and purified intact nuclei and by western blot analysis of subnuclear fractions. Double‐labeling assays using the anti‐DAGLα antibody and NeuN combined with Hoechst staining showed that only nuclei of neuronal origin were DAGLα positive. At high resolution, DAGLα‐signal displayed a punctate pattern in nuclear subdomains poor in Hoechst's chromatin and lamin B1 staining. In contrast, SC‐35‐ and NeuN‐signals (markers of the nuclear speckles) showed a high overlap with DAGLα within specific subdomains of the nuclear matrix. Among the members of the phospholipase C‐β (PLCβ) family, PLCβ1, PLCβ2, and PLCβ4 exhibited the same distribution with respect to chromatin, lamin B1, SC‐35, and NeuN as that described for DAGLα. Furthermore, by quantifying the basal levels of 2‐arachidonoylglycerol (2‐AG) by liquid chromatography and mass spectrometry (LC‐MS), and by characterizing the pharmacology of its accumulation, we describe the presence of a mechanism for 2‐AG production, and its PLCβ/DAGLα‐dependent biosynthesis in isolated nuclei. These results extend our knowledge about subcellular distribution of neuronal DAGLα, providing biochemical grounds to hypothesize a role for 2‐AG locally produced within the neuronal nucleus.

  相似文献   


18.
Endoscopic optical coherence tomography (OCT) is a noninvasive technology allowing for imaging of tissue microanatomies of luminal organs in real time. Conventional endoscopic OCT operates at 1300 nm wavelength region with a suboptimal axial resolution limited to 8‐20 μm. In this paper, we present the first ultrahigh‐resolution tethered OCT capsule operating at 800 nm and offering about 3‐ to 4‐fold improvement of axial resolution (plus enhanced imaging contrast). The capsule uses diffractive optics to manage chromatic aberration over a full ~200 nm spectral bandwidth centering around 830 nm, enabling to achieve super‐achromaticity and an axial resolution of ~2.6 μm in air. The performance of the OCT capsule is demonstrated by volumetric imaging of swine esophagus ex vivo and sheep esophagus in vivo, where fine anatomic structures including the sub‐epithelial layers are clearly identified. The ultrahigh resolution and excellent imaging contrast at 800 nm of the tethered capsule suggest the potential of the technology as an enabling tool for surveillance of early esophageal diseases on awake patients without the need for sedation.   相似文献   

19.
The convergent evolution of warning signals in unpalatable species, known as Müllerian mimicry, has been observed in a wide variety of taxonomic groups. This form of mimicry is generally thought to have arisen as a consequence of local frequency‐dependent selection imposed by sampling predators. However, despite clear evidence for local selection against rare warning signals, there appears an almost embarrassing amount of polymorphism in natural warning colors, both within and among populations. Because the model of predator cognition widely invoked to explain Müllerian mimicry (Müller's “fixed ” model) is highly simplified and has not been empirically supported; here, we explore the dynamical consequences of the optimal strategy for sampling unfamiliar prey. This strategy, based on a classical exploration–exploitation trade‐off, not only allows for a variable number of prey sampled, but also accounts for predator neophobia under some conditions. In contrast to Müller's “fixed ” sampling rule, the optimal sampling strategy is capable of generating a variety of dynamical outcomes, including mimicry but also regional and local polymorphism. Moreover, the heterogeneity of predator behavior across space and time that a more nuanced foraging strategy allows, can even further facilitate the emergence of both local and regional polymorphism in prey warning color.  相似文献   

20.

Background

Magnetic resonance imaging (MRI) of the lumbar spine is commonly used to identify the source of low back pain (LBP); however, its use has been questionable. Throughout the years, numerous lumbar phenotypes (e.g., endplate abnormalities, Modic changes, black disc) have been studied as possible pain generators. High-intensity zones (HIZs) are of particular interest as they may represent annular tears. However, for over three decades, there has been heated debate as to whether these imaging biomarkers are synonymous with LBP. Therefore, the following study addressed a systematic review of the reported literature addressing the relationship of HIZs and LBP.

Methods

A systematic review was conducted via MEDLINE, SCOPUS, Cochrane, PubMed, PubMed Central, EMBASE via Ovid, and Web of Science with the following search terms: “HIZ,” “high intensity zone,” or “high intensity zones” and “low back pain,” “pain,” “lumbago,” and/or “sciatica.” Specific exclusion criteria were also maintained. Two independent reviewers searched the literature, selected the studies, and extracted the data.

Results

We identified six studies from our search strategy that met the inclusion criteria from a total of 756 possible studies. One cross-sectional population-based study and five comparison studies were identified, which provided information regarding the prevalence of HIZs. The prevalence of HIZs was 3 to 61% in subjects with LBP and 2 to 3% in subjects without LBP. Only three studies suggested a significant association between the presence of HIZ and LBP with or without sciatica.

Conclusions

Our systematic review has found evidence that HIZs may be a possible risk factor for LBP; however, a mismatch of the clinical relevance of HIZs between studies still remains. The available evidence is limited by small sample size, heterogeneous study populations, and lack of standardized imaging methods for phenotyping. HIZs may be important lumbar biomarkers that demand further investigation and should be considered in the global imaging assessment of the spine, which may have immense clinical utility. Further large-scale studies with standardized imaging and classification techniques as well as the assessment of patterns of HIZs are necessary to better understand their role with LBP development.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号