首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Laser poration of the skin locally removes its outermost, barrier layer, and thereby provides a route for the diffusion of topically applied drugs. Ideally, no thermal damage would surround the pores created in the skin, as tissue coagulation would be expected to limit drug diffusion. Here, a femtosecond pulsed fiber laser is used to porate mammalian skin ex vivo. This first application of a hollow core negative curvature fiber (HC‐NCF) to convey a femtosecond pulsed, visible laser beam results in reproducible skin poration. The effect of applying ink to the skin surface, prior to ultra‐short pulsed ablation, has been examined and Raman spectroscopy reveals that the least, collateral thermal damage occurs in inked skin. Pre‐application of ink reduces the laser power threshold for poration, an effect attributed to the initiation of plasma formation by thermionic electron emission from the dye in the ink. Poration under these conditions significantly increases the percutaneous permeation of caffeine in vitro. Dye‐enhanced, plasma‐mediated ablation of the skin is therefore a potentially advantageous approach to enhance topical/transdermal drug absorption. The combination of a fiber laser and a HC‐NCF, capable of emitting and delivering femtosecond pulsed, visible light, may permit a compact poration device to be developed.

Using a femtosecond pulsed, visible laser beam to create an array of micropores in dyed mammalian skin, with little collateral, thermal damage, leads to an enhancement in the percutaneous permeation of caffeine in vitro.  相似文献   


2.
Ablation of tissue structures containing and surrounded by water differs from tissue ablation at a surface, not only theoretically, but also in terms of outcome. In contrast to the situation often observed with surface ablation, it is shown that the trabecular meshwork in the anterior chamber of the eye can be ablated cleanly and accurately with the 308 nm Excimer laser without causing collateral thermal damage. The reason for this is that in the trabecular meshwork, the ratio of radiation-absorbing tissue to water--which absorbs very little energy--is very small. A marked cooling effect thus results, which permits the development of only a very small amount of collateral thermal damage at the boundaries of the ablation zone.  相似文献   

3.
目的 :研究 10 64nm和 53 2nm波长激光在激光能量为 14 0mJ/pulse(脉冲 )时对犬心肌切割效率。方法 :用Q开关Nd :YAG 10 64和 53 2nm波长脉冲激光分别照射犬离体和在体心肌组织 ,光学显微镜和偏振光学显微镜行组织学分析 ,观察不同条件下激光切割组织的深度和光热对组织的损伤。结果 :离体和在体实验 ,10 64nm波长激光的切割效率高于 53 2nm(p <0 .0 1)。在体和离体实验显示 10 64nm激光能量和重复率相同时 ,所致的切割效率无明显差异 (p >0 .0 5) ,血液对 10 64nm激光的切割效率影响较小。相反 ,在 53 2nm时血液对其影响较大 ,相同的激光能量和重复率 ,离体实验切割效率高于在体 (p <0 .0 1)。 10 64nm激光所致的光热和机械损伤均轻于 53 2nm激光。结论 :在切割效率方面 ,10 64nm激光比 53 2nm更适用于TMLR。 10 64nmQ开关Nd :YAG激光可通过光导纤维传输 ,是TMLR的一个有潜力的激光源  相似文献   

4.
The Er:YAG laser is currently used for bone ablation. However, the effect of Er:YAG laser irradiation on bone healing remains unclear. The aim of this study was to investigate bone healing following ablation by laser irradiation as compared with bur drilling. Rat calvarial bone was ablated using Er:YAG laser or bur with water coolant. Er:YAG laser effectively ablated bone without major thermal changes. In vivo micro‐computed tomography analysis revealed that laser irradiation showed significantly higher bone repair ratios than bur drilling. Scanning electron microscope analysis showed more fibrin deposition on laser‐ablated bone surfaces. Microarray analysis followed by gene set enrichment analysis revealed that IL6/JAK/STAT3 signaling and inflammatory response gene sets were enriched in bur‐drilled bone at 6 hours, whereas the E2F targets gene set was enriched in laser‐irradiated bone. Additionally, Hspa1a and Dmp1 expressions were increased and Sost expression was decreased in laser‐irradiated bone compared with bur‐drilled bone. In granulation tissue formed after laser ablation, Alpl and Gblap expressions increased compared to bur‐drilled site. Immunohistochemistry showed that osteocalcin‐positive area was increased in the laser‐ablated site. These results suggest that Er:YAG laser might accelerate early new bone formation with advantageous surface changes and cellular responses for wound healing, compared with bur‐drilling.   相似文献   

5.
Water jet techniques have been used in industrial cutting, drilling and cleaning applications for more than 30 years. Plain water is typically used for the cutting of non-metallic materials. The addition of abrasive substances to the stream allows almost any material to be cut. The first medical applications were reported in the early 1980s, when the water jet was used to cut organs. The present study investigates the use of water jet cutting technology for endoprosthesis revision surgery. Bone and PMMA (polymethylmethacrylate) samples were cut at different pressures using an industrial water jet cutting device. Using plain water at 400 bar, PMMA was cut selectively without damaging the bone; above 400 bar, bone was also cut, but the cutting depths in PMMA were significantly greater (p < 0.05). Adding a water-soluble abrasive disaccharide to the water results in a significantly higher removal rate for both materials (p < 0.05), but selectivity is lost, although the differences in cutting depth between the two materials was significant (p < 0.05). With an abrasive, the quality of the cut was better for both materials. The water jet technology--in particular the abrasive technique--can be used to cut biomaterials such as bone and bone cement. The diameter of the jet is a great advantage when working in the confined area at the prosthesis interface. The cutting process is essentially cold, thus eliminating a thermal effect, and the jet reaction forces are relatively low. Accurate manipulation of the hydro jet nozzle is possible both manually and by robot. The results obtained show that it is possible to remove prostheses with this cutting technique, rapidly and with little damage to the surrounding tissue. Problem areas are the development of sterile pumps and the "depth control" of the jet.  相似文献   

6.
Superficial photothermal laser ablation (SPLA) may be useful as a therapeutic approach producing a depth of injury that is sufficient to eliminate mucosal lesion but not deep enough to induce thermal effects in deeper tissue layers. The purpose of this preliminary study is twofold: (a) to describe design steps of a fiber probe capable of delivering a tightly focused laser beam, including Monte‐Carlo‐based simulations, and (b) to complete the initial testing of the probe in a sheep esophagus model, ex vivo. The cone‐shaped (tapered) fiber tip was obtained by chemical etching of the optical fiber. A 1505 nm diode laser providing power up to 500 mW was operated in continuous wave. The successful SPLA of the sheep mucosa layer was demonstrated for various speed‐power combinations, including 300 mW laser power at a surface scanning rate of 0.5 mm/s and 450 mW laser power at a surface scanning rate of 2.0 mm/s. Upon further development, this probe may be useful for endoscopic photothermal laser ablation of the mucosa layer using relatively low laser power.  相似文献   

7.
The aim of this study is to understand the effect of varying laser repetition rate on thermal energy accumulation and dissipation as well as femtosecond Laser Induced Breakdown Spectroscopy (fsLIBS) signals, which may help create the framework for clinical translation of femtosecond lasers for surgical procedures. We study the effect of repetition rates on ablation widths, sample temperature, and LIBS signal of bone. SEM images were acquired to quantify the morphology of the ablated volume and fsLIBS was performed to characterize changes in signal intensity and background. We also report for the first time experimentally measured temperature distributions of bone irradiated with femtosecond lasers at repetition rates below and above carbonization conditions. While high repetition rates would allow for faster cutting, heat accumulation exceeds heat dissipation and results in carbonization of the sample. At repetition rates where carbonization occurs, the sample temperature increases to a level that is well above the threshold for irreversible cellular damage. These results highlight the importance of the need for careful selection of the repetition rate for a femtosecond laser surgery procedure to minimize the extent of thermal damage to surrounding tissues and prevent misclassification of tissue by fsLIBS analysis.

  相似文献   


8.
Ultrashort pulse lasers offer great promise for tissue resection with exceptional precision and minimal thermal damage. Surgery in the bowel requires high precision and minimal necrotic tissue to avoid severe complications such as perforation. The deployment of ultrashort lasers in minimally invasive or endoscopic procedures has been hindered by the lack of suitable optical fibres for high peak powers. However, recent developments of hollow core microstructured fibres provide potential for delivery of such pulses throughout the body. In this study, analysis of laser ablation via a scanning galvanometer on a porcine colon tissue model is presented. A thermally damaged region (<85 μm) and fine depth control of ablation using the pulse energies 46 and 33 μJ are demonstrated. It is further demonstrated that such pulses suitable for precision porcine colon resection can be flexibly delivered via a hollow core negative curvature fibre (HC‐NCF) and again ablation depth can be controlled with a thermally damaged region <85 μm. Ablation volumes are comparable to that of early stage lesions in the inner lining of the colon. This study concludes that the combination of ultrashort pulses and flexible fibre delivery via HC‐NCF present a viable route to new minimally invasive surgical procedures.  相似文献   

9.
Mid-infrared free-electron lasers have proven adept in surgical applications. When tuned to wavelengths between 6 and 7 microm, such lasers remove defined volumes of soft tissue with very little collateral damage. Previous attempts to explain the wavelength-dependence of collateral damage have invoked a wavelength-dependent loss of protein structural integrity. However, the molecular nature of this structural failure has been heretofore ill-defined. In this report, we evaluate several candidates for the relevant transition by analyzing the nonvolatile debris ejected during ablation. Porcine corneas were ablated with a free-electron laser tuned to 2.77 or 6.45 microm-wavelengths with matched absorption coefficients for hydrated corneas that respectively target either tissue water or protein. The debris ejected during these ablations was characterized via gel electrophoresis, as well as Fourier transform infrared spectroscopy, micro-Raman and 13C-NMR spectroscopy. We find that high-fluence (240 J/cm2) ablation at 6.45 microm, but not at 2.77 microm, leads to protein fragmentation accompanied by the accumulation of nitrile and alkyne species. The candidate transition most consistent with these observations is scission of the collagen protein backbone at N-alkylamide bonds. Identifying this transition is a key step toward understanding the observed wavelength-dependence of collateral damage in mid-infrared laser ablation.  相似文献   

10.
Lasers have in principle the capability to cut at the level of a single cell, the fundamental limit to minimally invasive procedures and restructuring biological tissues. To date, this limit has not been achieved due to collateral damage on the macroscale that arises from thermal and shock wave induced collateral damage of surrounding tissue. Here, we report on a novel concept using a specifically designed Picosecond IR Laser (PIRL) that selectively energizes water molecules in the tissue to drive ablation or cutting process faster than thermal exchange of energy and shock wave propagation, without plasma formation or ionizing radiation effects. The targeted laser process imparts the least amount of energy in the remaining tissue without any of the deleterious photochemical or photothermal effects that accompanies other laser wavelengths and pulse parameters. Full thickness incisional and excisional wounds were generated in CD1 mice using the Picosecond IR Laser, a conventional surgical laser (DELight Er:YAG) or mechanical surgical tools. Transmission and scanning electron microscopy showed that the PIRL laser produced minimal tissue ablation with less damage of surrounding tissues than wounds formed using the other modalities. The width of scars formed by wounds made by the PIRL laser were half that of the scars produced using either a conventional surgical laser or a scalpel. Aniline blue staining showed higher levels of collagen in the early stage of the wounds produced using the PIRL laser, suggesting that these wounds mature faster. There were more viable cells extracted from skin using the PIRL laser, suggesting less cellular damage. β-catenin and TGF-β signalling, which are activated during the proliferative phase of wound healing, and whose level of activation correlates with the size of wounds was lower in wounds generated by the PIRL system. Wounds created with the PIRL systsem also showed a lower rate of cell proliferation. Direct comparison of wound healing responses to a conventional surgical laser, and standard mechanical instruments shows far less damage and near absence of scar formation by using PIRL laser. This new laser source appears to have achieved the long held promise of lasers in minimally invasive surgery.  相似文献   

11.
Heat generation during orthopaedic bone cutting operations may cause thermal bone damage. During the bone cutting, the maximum temperature occurs at the point of contact between the bone and the cutting tool. However, this temperature is difficult to measure. Many researchers have attempted to measure this temperature using a thermocouple; however, limitations of the thermocouple makes it difficult to determine the maximum temperature at the point of contact. In order to solve this problem, in this study, two infrared thermometers are used to measure the fresh-milled surface temperature, and the maximum temperature was extrapolated by a moving plane heat source solution. The estimated maximum temperature increment varied from 49 to 115 degrees C under various cutting conditions. These results showed that the thermal damage may reach up to 1.9 mm in depth during round bur milling. A larger feed rate and a smaller cutting depth decreased the maximum temperature.  相似文献   

12.
We investigate the use of spatially resolved diffuse imaging to track a fluid jet delivered at high speed into skin tissue. A jet injector with a short needle to deliver drugs beneath the dermis, is modified to incorporate a laser beam into the jet, which is ejected into ex vivo porcine tissue. The diffuse light emitted from the side and top of the tissue sample is recorded using high‐speed videography. Similar experiments, using a depth‐controlled fiber optic source, generate a reference dataset. The side light distribution is related to source depth for the controlled‐source experiments and used to track the effective source depth of the injections. Postinjection X‐ray images show agreement between the jet penetration and ultimate light source depth. The surface light intensity profile is parameterized with a single parameter and an exponential function is used to relate this parameter to source depth for the controlled‐source data. This empirical model is then used to estimate the effective source depth from the surface profile of the injection experiments. The depth estimates for injections into fat remain close to the side depth estimates, with a root‐mean‐square error of 1.1 mm, up to a source depth of 8 mm.   相似文献   

13.
In the present study, the elemental compositions of fat and nerve tissue during their plasma mediated laser ablation are studied in the context of tissue differentiation for laser surgery applications by using Laser‐Induced Breakdown Spectroscopy (LIBS). Tissue samples of porcine fat and nerve were prepared as ex vivo experimental objects. Plasma mediated laser ablation is performed using an Nd : YAG laser in open air and under normal stray light conditions. The performed measurements suggest that the two tissue types show a high similarity in terms of qualitative elemental composition while at the same time revealing a distinct difference in the concentration of the constituent elements. Different analysis approaches are evaluated and discussed to optimize the tissue‐differentiation performance of the LIBS approach.

Plasma mediated laser tissue ablation.  相似文献   


14.
There is a huge interest in developing strategies to effectively eliminate biofilms due to their negative impact in both industrial and clinical settings. In this study, structural damage was induced on two day‐old B. subtilis biofilms using the interaction of 532 nm pulsed laser with gold thin films. Radiant exposure of 225 mJ/cm2 induced distinct changes on the surface structure and overall morphology of the matured biofilms after laser irradiation. Moreover, at the radiant exposure used, changes in the colour and viscosity of the biofilm were observed which may indicate a compromised extracellular matrix. Irradiated biofilms in the presence of gold film also showed strong propidium iodide signal which implies an increase in the number of dead bacterial cells after laser treatment. Thus, this laser‐based technique is a promising approach in targeting and eradicating matured biofilms attached on surfaces such as medical implants.

  相似文献   


15.
A mathematical model is developed and validated to predict the depth of cut in potato tuber slabs as a function of laser power and travel speed. The model considers laser processing parameters such as input power, spot size and exposure time as well as the properties of the material being cut such as specific heat, thermal conductivity, surface reflectance, etc. The model also considers the phase change of water in potato and the ignition temperature of the solid portion. The composition of the potato tuber is assumed to be of water and solid. The model also assumes that the ablation process is accomplished through ejection of liquid water, debris and water vapour, and combustion of solid. A CO2 laser operating in c.w. mode was chosen for the experimental work because water absorbs laser energy highly at 10.6 μm, and CO2 laser units with relatively high output power are available. Slabs of potato tuber were chosen to be laser processed since potato contains high moisture and large amounts of relatively homogeneous tissue. The results of the preliminary calculations and experiments concluded that the model is able to predict the depth of cut in potato tuber parenchyma when subjected to a CO2 laser beam.  相似文献   

16.
Experimental investigations aimed at assessing the effectiveness of femtosecond (FS) laser ablation for creating microscale features on electrospun poly(ε‐caprolactone) (PCL)/gelatin nanofiber tissue scaffold capable of controlling cell distribution are described. Statistical comparisons of the fiber diameter and surface porosity on laser‐machined and as‐spun surface were made and results showed that laser ablation did not change the fiber surface morphology. The minimum feature size that could be created on electrospun nanofiber surfaces by direct‐write ablation was measured over a range of laser pulse energies. The minimum feature size that could be created was limited only by the pore size of the scaffold surface. The chemical states of PCL/gelatin nanofiber surfaces were measured before and after FS laser machining by attenuated total reflectance Fourier transform infrared (ATR‐FTIR) spectroscopy and X‐ray photoelectron spectroscopy (XPS) and showed that laser machining produced no changes in the chemistry of the surface. In vitro, mouse embryonic stem cells (mES cells) were cultured on as‐spun surfaces and in laser‐machined microwells. Cell densities were found to be statistically indistinguishable after 1 and 2 days of growth. Additionally, confocal microscope imaging confirmed that spreading of mES cells cultured within laser‐machined microwells was constrained by the cavity walls, the expected and desired function of these cavities. The geometric constraint caused statistically significant smaller density of cells in microwells after 3 days of growth. It was concluded that FS laser ablation is an effective process for microscale structuring of these electrospun nanofiber tissue scaffold surfaces. Biotechnol. Bioeng. 2011; 108:116–126. © 2010 Wiley Periodicals, Inc.  相似文献   

17.
目的:波前像差引导的准分子激光角膜消融是屈光手术的新方法,研究人眼波前像差的测量原理、方法、表示、人眼波前像差准分子激光矫正的原理,以此理论用于准分子激光人眼像差矫正系统。方法:采用理论研究、计算机模拟、实验室实验等手段。分析人眼像差的概念和产生的原因,用数学的Zern ike多项式来表示像差,理论上定量分析Zern ike多项式表示的波前像差与角膜切削深度的关系,研究准分子激光切削角膜的机理,研究准分子激光进行矫正人眼像差的原理框图。结果:通过计算机模拟和实验室实验,用准分子激光矫正低阶和高阶像差是可行的。结论:用波前像差来引导屈光手术,使人眼的视力能够达到20/10上,并能避免当前PRK、LASIK屈光手术前后像差增大而引起的对视觉质量的影响。  相似文献   

18.
19.
Momokawa N  Kadono Y  Kudoh H 《Annals of botany》2011,108(7):1299-1306

Background and Aims

For heterophyllous amphibious plants that experience fluctuating water levels, it is critical to control leaf development precisely in response to environmental cues that can serve as a quantitative index of water depth. Light quality can serve as such a cue because the ratio of red light relative to far-red light (R/FR) increases and blue-light intensity decreases with increasing water depth. Growth experiments were conducted to examine how R/FR and blue-light intensity alter leaf morphology of a heterophyllous amphibious plant, Rotala hippuris.

Methods

Using combinations of far red (730 nm), red (660 nm) and blue (470 nm) light-emitting diodes (LEDs), growth experiments were used to quantitatively evaluate the effects of the R/FR ratio and blue-light intensity on leaf morphology.

Key Results

Under the natural light regime in an outside growth garden, R. hippuris produced distinct leaves under submerged and aerial conditions. R/FR and blue-light intensity were found to markedly affect heterophyllous leaf formation. Higher and lower R/FR caused leaf characters more typical of submerged and aerial leaves, respectively, in both aerial and submerged conditions, in accordance with natural distribution of leaf types and light under water. High blue light caused a shift of trait values toward those of typical aerial leaves, and the response was most prominent under conditions of R/FR that were expected near the water surface.

Conclusions

R/FR and blue-light intensity provides quantitative cues for R. hippuris to detect water depth and determine the developmental fates of leaves, especially near the water surface. The utilization of these quantitative cues is expected to be important in habitats where plants experience water-level fluctuation.  相似文献   

20.
The physical mechanisms that achieve tissue removal through the delivery of short pulses of high-intensity infrared laser radiation, in a process known as laser ablation, remain obscure. The thermodynamic response of biological tissue to pulsed infrared laser irradiation was investigated by measuring and analyzing the stress transients generated by Q-sw Er:YSGG (lambda = 2.79 microns) and TEA CO2 (lambda = 10.6 microns) laser irradiation of porcine dermis using thin-film piezoelectric transducers. For radiant exposures that do not produce material removal, the stress transients are consistent with thermal expansion of the tissue samples. The temporal structure of the stress transients generated at the threshold radiant exposure for ablation indicates that the onset of material removal is delayed with respect to irradiation. Once material removal is achieved, the magnitude of the peak compressive stress and its variation with radiant exposure are consistent with a model that considers this process as an explosive event occurring after the laser pulse. This mechanism is different from ArF- and KrF-excimer laser ablation where absorption of ultraviolet radiation by the collagenous tissue matrix leads to tissue decomposition during irradiation and results in material removal via rapid surface vaporization. It appears that under the conditions examined in this study, explosive boiling of tissue water is the process that mediates the ablation event. This study provides evidence that the dynamics and mechanism of tissue ablation processes can be altered by targeting tissue water rather than the tissue structural matrix.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号