首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Optical projection tomography (OPT) provides a non-invasive 3-D imaging modality that can be applied to longitudinal studies of live disease models, including in zebrafish. Current limitations include the requirement of a minimum number of angular projections for reconstruction of reasonable OPT images using filtered back projection (FBP), which is typically several hundred, leading to acquisition times of several minutes. It is highly desirable to decrease the number of required angular projections to decrease both the total acquisition time and the light dose to the sample. This is particularly important to enable longitudinal studies, which involve measurements of the same fish at different time points. In this work, we demonstrate that the use of an iterative algorithm to reconstruct sparsely sampled OPT data sets can provide useful 3-D images with 50 or fewer projections, thereby significantly decreasing the minimum acquisition time and light dose while maintaining image quality. A transgenic zebrafish embryo with fluorescent labelling of the vasculature was imaged to acquire densely sampled (800 projections) and under-sampled data sets of transmitted and fluorescence projection images. The under-sampled OPT data sets were reconstructed using an iterative total variation-based image reconstruction algorithm and compared against FBP reconstructions of the densely sampled data sets. To illustrate the potential for quantitative analysis following rapid OPT data acquisition, a Hessian-based method was applied to automatically segment the reconstructed images to select the vasculature network. Results showed that 3-D images of the zebrafish embryo and its vasculature of sufficient visual quality for quantitative analysis can be reconstructed using the iterative algorithm from only 32 projections—achieving up to 28 times improvement in imaging speed and leading to total acquisition times of a few seconds.  相似文献   

2.
The experimental process of collecting images from macromolecules in an electron microscope is such that it does not allow for prior specification of the angular distribution of the projection images. As a consequence, an uneven distribution of projection directions may occur. Concerns have been raised recently about the behavior of 3D reconstruction algorithms for the case of unevenly distributed projections. It has been illustrated on experimental data that in the case of a heavily uneven distribution of projection directions some algorithms tend to elongate the reconstructed volumes along the overloaded direction so much as to make a quantitative biological analysis impossible. In answer to these concerns we have developed a strategy for quantitative comparison and optimization of 3D reconstruction algorithms. We apply this strategy to quantitatively analyze algebraic reconstruction techniques (ART) with blobs, simultaneous iterative reconstruction techniques (SIRT) with voxels, and weighted backprojection (WBP). We show that the elongation artifacts that had been previously reported can be strongly reduced. With our specific choices for the free parameters of the three algorithms, WBP reconstructions tend to be inferior to those obtained with either SIRT or ART and the results obtained with ART are comparable to those with SIRT, but at a very small fraction of the computational cost of SIRT.  相似文献   

3.
A single-shot adaptation of Optical Projection Tomography (OPT) for high-speed volumetric snapshot imaging of dynamic mesoscopic biological samples is presented. Conventional OPT has been applied to in vivo imaging of animal models such as D. rerio, but the sequential acquisition of projection images typically requires samples to be immobilized during the acquisition. A proof-of-principle system capable of single-shot tomography of a ~1 mm3 volume is presented, demonstrating camera-limited rates of up to 62.5 volumes/s, which has been applied to 3D imaging of a freely swimming zebrafish embryo. This is achieved by recording eight projection views simultaneously on four low-cost CMOS cameras. With no stage required to rotate the sample, this single-shot OPT system can be implemented with a component cost of under £5000. The system design can be adapted to different sized fields of view and may be applied to a broad range of dynamic samples, including high throughput flow cytometry applied to model organisms and fluid dynamics studies.  相似文献   

4.

Background

Despite its superb lateral resolution, flat-panel-detector (FPD) based tomosynthesis suffers from low contrast and inter-plane artifacts caused by incomplete cancellation of the projection components stemming from outside the focal plane. The incomplete cancellation of the projection components, mostly due to the limited scan angle in the conventional tomosynthesis scan geometry, often makes the image contrast too low to differentiate the malignant tissues from the background tissues with confidence.

Methods

In this paper, we propose a new method to suppress the inter-plane artifacts in FPD-based tomosynthesis. If 3D whole volume CT images are available before the tomosynthesis scan, the CT image data can be incorporated into the tomosynthesis image reconstruction to suppress the inter-plane artifacts, hence, improving the image contrast. In the proposed technique, the projection components stemming from outside the region-of-interest (ROI) are subtracted from the measured tomosynthesis projection data to suppress the inter-plane artifacts. The projection components stemming from outside the ROI are calculated from the 3D whole volume CT images which usually have lower lateral resolution than the tomosynthesis images. The tomosynthesis images are reconstructed from the subtracted projection data which account for the x-ray attenuation through the ROI. After verifying the proposed method by simulation, we have performed both CT scan and tomosynthesis scan on a phantom and a sacrificed rat using a FPD-based micro-CT.

Results

We have measured contrast-to-noise ratio (CNR) from the tomosynthesis images which is an indicator of the residual inter-plane artifacts on the focal-plane image. In both cases of the simulation and experimental imaging studies of the contrast evaluating phantom, CNRs have been significantly improved by the proposed method. In the rat imaging also, we have observed better visual contrast from the tomosynthesis images reconstructed by the proposed method.

Conclusions

The proposed tomosynthesis technique can improve image contrast with aids of 3D whole volume CT images. Even though local tomosynthesis needs extra 3D CT scanning, it may find clinical applications in special situations in which extra 3D CT scan is already available or allowed.  相似文献   

5.
We describe a quantitative fluorescence projection tomography technique which measures the 3‐D fluorescence lifetime distribution in optically cleared specimens up 1 cm in diameter. This is achieved by acquiring a series of wide‐field time‐gated images at different relative time delays with respect to a train of excitation pulses, at a number of projection angles. For each time delay, the 3‐D time‐gated intensity distribution is reconstructed using a filtered back projection algorithm and the fluorescence lifetime subsequently determined for each reconstructed horizontal plane by iterative fitting to a mono‐exponential decay. Due to its inherently ratiometric nature, fluorescence lifetime is robust against intensity based artefacts as well as producing a quantitative measure of the fluorescence signal. We present a 3‐D fluorescence lifetime reconstruction of a mouse embryo labelled with an alexa‐488 conjugated antibody targeted to the neurofilament, which clearly differentiates between the extrinsic label and the autofluorescence, particularly from the heart and dorsal aorta. (© 2008 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

6.
PurposeLimited-angle CT imaging is an effective technique to reduce radiation. However, existing image reconstruction methods can effectively reduce streak artifacts but fail to suppress those artifacts around edges due to incomplete projection data. Thus, a modified NLM (mNLM) based reconstruction method is proposed.MethodsSince the artifacts around edges mainly exist in local position, it is possible to restore the true pixels in artifacts using pixels located in artifacts-free regions. In each iteration, mNLM is performed on image reconstructed by ART followed by positivity constraint. To solve the problem caused by ART-mNLM that there is undesirable information that may appear in the image, ART-TV is then utilized in the following iterative process after ART-mNLM iterates for a number of iterations. The proposed algorithm is named as ART-mNLM/TV.ResultsSimulation experiments are performed to validate the feasibility of algorithm. When the scanning range is [0, 150°], our algorithm outperforms the ART-NLM and ART-TV with more than 40% and 29% improvement in terms of SNR and with more than 58% and 49% reduction in terms of MAE. Consistently, reconstructed images from real projection data also demonstrate the effectiveness of presented algorithm.ConclusionThis paper uses mNLM which benefits from redundancy of information across the whole image, to recover the true value of pixels in artifacts region by utilizing pixels from artifact-free regions, and artifacts around the edges can be mitigated effectively. Experiments show that the proposed ART-mNLM/TV is able to achieve better performances compared to traditional methods.  相似文献   

7.

Background

Non-Cartesian trajectories are used in a variety of fast imaging applications, due to the incoherent image domain artifacts they create when undersampled. While the gridding technique is commonly utilized for reconstruction, the incoherent artifacts may be further removed using compressed sensing (CS). CS reconstruction is typically done using conjugate-gradient (CG) type algorithms, which require gridding and regridding to be performed at every iteration. This leads to a large computational overhead that hinders its applicability.

Methods

We sought to develop an alternative method for CS reconstruction that only requires two gridding and one regridding operation in total, irrespective of the number of iterations. This proposed technique is evaluated on phantom images and whole-heart coronary MRI acquired using 3D radial trajectories, and compared to conventional CS reconstruction using CG algorithms in terms of quantitative vessel sharpness, vessel length, computation time, and convergence rate.

Results

Both CS reconstructions result in similar vessel length (P = 0.30) and vessel sharpness (P = 0.62). The per-iteration complexity of the proposed technique is approximately 3-fold lower than the conventional CS reconstruction (17.55 vs. 52.48 seconds in C++). Furthermore, for in-vivo datasets, the convergence rate of the proposed technique is faster (60±13 vs. 455±320 iterations) leading to a ∼23-fold reduction in reconstruction time.

Conclusions

The proposed reconstruction provides images of similar quality to the conventional CS technique in terms of removing artifacts, but at a much lower computational complexity.  相似文献   

8.
Recent progress in three‐dimensional optical imaging techniques allows visualization of many comprehensive biological specimens. Optical clearing methods provide volumetric and quantitative information by overcoming the limited depth of light due to scattering. However, current imaging technologies mostly rely on the synthetic or genetic fluorescent labels, thus limits its application to whole‐body visualization of generic mouse models. Here, we report a label‐free optical projection tomography (LF‐OPT) technique for quantitative whole mouse embryo imaging. LF‐OPT is based on the attenuation contrast of light rather than fluorescence, and it utilizes projection imaging technique similar to computed tomography for visualizing the volumetric structure. We demonstrate this with a collection of mouse embryo morphologies in different stages using LF‐OPT. Additionally, we extract quantitative organ information applicable toward high‐throughput phenotype screening. Our results indicate that LF‐OPT can provide multi‐scale morphological information in various tissues including bone, which can be difficult in conventional optical imaging technique.  相似文献   

9.
In practical applications of computed tomography imaging (CT), it is often the case that the set of projection data is incomplete owing to the physical conditions of the data acquisition process. On the other hand, the high radiation dose imposed on patients is also undesired. These issues demand that high quality CT images can be reconstructed from limited projection data. For this reason, iterative methods of image reconstruction have become a topic of increased research interest. Several algorithms have been proposed for few-view CT. We consider that the accurate solution of the reconstruction problem also depends on the system matrix that simulates the scanning process. In this work, we analyze the application of the Siddon method to generate elements of the matrix and we present results based on real projection data.  相似文献   

10.
In this study, a novel dual-energy (DE) material decomposition reconstruction algorithm (DEMDRA) was developed using projection data with the aim of reducing metal artifacts during digital tomosynthesis (DT) for implants. Using the three-material decomposition method and decomposition projection data specific for each material, a novel DEMDRA was implemented to reduce metal artifacts via weighted hybrid reconstructed images [maximum likelihood expectation maximization (MLEM) and shift-and-add (SAA)]. Pulsed X-ray exposures with rapid switching between low and high tube potential kVp were used for DE-DT imaging, and the images were compared using conventional filtered back projection (FBP), MLEM, the simultaneous algebraic reconstruction technique total variation (SART-TV), virtual monochromatic processing, and metal artifact reduction (MAR)-processing algorithms. The reductions in metal artifacts were compared using an artifact index (AI), Gumbel distribution of the largest variations, and the artifact spread functions (ASFs) for prosthesis phantom. The novel DEMDRA yielded an adequately effective overall performance in terms of the AI, and the resulting images yielded good results independently of the type of metal used in the prosthetic phantom, as well as good noise artifact removal, particularly at greater distances from metal objects. Furthermore, the DEMDRA represented the minimum in the model of largest variations. Regarding the ASF analysis, the novel DEMDRA yielded superior metal artifact reduction when compared with conventional reconstruction algorithms with and without MAR processing. Finally, the DEMDRA was particularly useful for reducing high-frequency artifacts.  相似文献   

11.
An approach to Magnetic Resonance (MR) image reconstruction from undersampled data is proposed. Undersampling artifacts are removed using an iterative thresholding algorithm applied to nonlinearly transformed image block arrays. Each block array is transformed using kernel principal component analysis where the contribution of each image block to the transform depends in a nonlinear fashion on the distance to other image blocks. Elimination of undersampling artifacts is achieved by conventional principal component analysis in the nonlinear transform domain, projection onto the main components and back-mapping into the image domain. Iterative image reconstruction is performed by interleaving the proposed undersampling artifact removal step and gradient updates enforcing consistency with acquired k-space data. The algorithm is evaluated using retrospectively undersampled MR cardiac cine data and compared to k-t SPARSE-SENSE, block matching with spatial Fourier filtering and k-t ℓ1-SPIRiT reconstruction. Evaluation of image quality and root-mean-squared-error (RMSE) reveal improved image reconstruction for up to 8-fold undersampled data with the proposed approach relative to k-t SPARSE-SENSE, block matching with spatial Fourier filtering and k-t ℓ1-SPIRiT. In conclusion, block matching and kernel methods can be used for effective removal of undersampling artifacts in MR image reconstruction and outperform methods using standard compressed sensing and 1-regularized parallel imaging methods.  相似文献   

12.
The aim of this study is to investigate whether reliable and accurate 3D geometrical models of the murine aortic arch can be constructed from sparse-view data in vivo micro-CT acquisitions. This would considerably reduce acquisition time and X-ray dose. In vivo contrast-enhanced micro-CT datasets were reconstructed using a conventional filtered back projection algorithm (FDK), the image space reconstruction algorithm (ISRA) and total variation regularized ISRA (ISRA-TV). The reconstructed images were then semi-automatically segmented. Segmentations of high- and low-dose protocols were compared and evaluated based on voxel classification, 3D model diameters and centerline differences. FDK reconstruction does not lead to accurate segmentation in the case of low-view acquisitions. ISRA manages accurate segmentation with 1024 or more projection views. ISRA-TV needs a minimum of 256 views. These results indicate that accurate vascular models can be obtained from micro-CT scans with 8 times less X-ray dose and acquisition time, as long as regularized iterative reconstruction is used.  相似文献   

13.
本文提出了一种基于空间频率滤波的多曝光融合的高动态投影层析三维成像方法,实现了活体斑马鱼(17 mm × 4 mm,最大厚度为2.33 mm,最小厚度为0.29 mm)的三维结构成像. 通过相机采用不同曝光时间记录系列吸收图像,将每张图像取变换到频域去除低频后,将各张滤波后叠加并逆傅里叶变换回空域,对变换后的图像进行归一化处理,最终获得高动态图像. 在每个投影角度获得这种高动态吸收投影图像,进行滤波反投影算法重建,获得高动态的整条斑马鱼三维结构信息. 实验成像结果表明,这种空间频率滤波多曝光融合的高动态光学投影层析三维成像研究,可以获得复杂结构更丰富的空间信息,对斑马鱼等模式生物早期胚胎生长发育进程进行监测和定量评估有一定的应用前景.  相似文献   

14.
The Filtered Back-Projection (FBP) algorithm and its modified versions are the most important techniques for CT (Computerized tomography) reconstruction, however, it may produce aliasing degradation in the reconstructed images due to projection discretization. The general iterative reconstruction (IR) algorithms suffer from their heavy calculation burden and other drawbacks. In this paper, an iterative FBP approach is proposed to reduce the aliasing degradation. In the approach, the image reconstructed by FBP algorithm is treated as the intermediate image and projected along the original projection directions to produce the reprojection data. The difference between the original and reprojection data is filtered by a special digital filter, and then is reconstructed by FBP to produce a correction term. The correction term is added to the intermediate image to update it. This procedure can be performed iteratively to improve the reconstruction performance gradually until certain stopping criterion is satisfied. Some simulations and tests on real data show the proposed approach is better than FBP algorithm or some IR algorithms in term of some general image criteria. The calculation burden is several times that of FBP, which is much less than that of general IR algorithms and acceptable in the most situations. Therefore, the proposed algorithm has the potential applications in practical CT systems.  相似文献   

15.
Fluorescence lifetime imaging (FLIM) combined with optical projection tomography (OPT) has the potential to map Förster resonant energy transfer (FRET) readouts in space and time in intact transparent or near transparent live organisms such as zebrafish larvae, thereby providing a means to visualise cell signalling processes in their physiological context. Here the first application of FLIM OPT to read out biological function in live transgenic zebrafish larvae using a genetically expressed FRET biosensor is reported. Apoptosis, or programmed cell death, is mapped in 3‐D by imaging the activity of a FRET biosensor that is cleaved by Caspase 3, which is a key effector of apoptosis. Although apoptosis is a naturally occurring process during development, it can also be triggered in a variety of ways, including through gamma irradiation. FLIM OPT is shown here to enable apoptosis to be monitored over time, in live zebrafish larvae via changes in Caspase 3 activation following gamma irradiation at 24 hours post fertilisation. Significant apoptosis was observed at 3.5 hours post irradiation, predominantly in the head region.

  相似文献   


16.
Algorithms for three-dimensional (3D) reconstruction of objects based on their projections are essential in various biological and medical imaging modalities. In cryo-electron tomography (CET) a major challenge for reconstruction is the limited range of projection angles, which manifests itself as a “missing wedge” of data in Fourier space making the reconstruction problem ill-posed. Here, we apply an iterative reconstruction method that makes use of nonuniform fast Fourier transform (NUFFT) to the reconstruction of cryo-electron tomograms. According to several measures the reconstructions are superior to those obtained using conventional methods, most notably weighted backprojection. Most importantly, we show that it is possible to fill in partially the unsampled region in Fourier space with meaningful information without making assumptions about the data or applying prior knowledge. As a consequence, particles of known structure can be localized with higher confidence in cryotomograms and subtomogram averaging yields higher resolution densities.  相似文献   

17.
Innovations in CT have been impressive among imaging and medical technologies in both the hardware and software domain. The range and speed of CT scanning improved from the introduction of multidetector-row CT scanners with wide-array detectors and faster gantry rotation speeds. To tackle concerns over rising radiation doses from its increasing use and to improve image quality, CT reconstruction techniques evolved from filtered back projection to commercial release of iterative reconstruction techniques, and recently, of deep learning (DL)-based image reconstruction. These newer reconstruction techniques enable improved or retained image quality versus filtered back projection at lower radiation doses. DL can aid in image reconstruction with training data without total reliance on the physical model of the imaging process, unique artifacts of PCD-CT due to charge sharing, K-escape, fluorescence x-ray emission, and pulse pileups can be handled in the data-driven fashion. With sufficiently reconstructed images, a well-designed network can be trained to upgrade image quality over a practical/clinical threshold or define new/killer applications. Besides, the much smaller detector pixel for PCD-CT can lead to huge computational costs with traditional model-based iterative reconstruction methods whereas deep networks can be much faster with training and validation. In this review, we present techniques, applications, uses, and limitations of deep learning-based image reconstruction methods in CT.  相似文献   

18.
High-performance confocal system for microscopic or endoscopic applications   总被引:1,自引:0,他引:1  
We designed a high-performance confocal system that can be easily adapted to an existing light microscope or coupled with an endoscope for remote imaging. The system employs spatially and temporally patterned illumination produced by one of several mechanisms, including a micromirror array video projection device driven by a computer video source or a microlens array scanned by a piezo actuator in the microscope illumination path. A series of subsampled "component" video images are acquired from a solid-state video camera. Confocal images are digitally reconstructed using "virtual pinhole" synthetic aperture techniques applied to the collection of component images. Unlike conventional confocal techniques that raster scan a single detector and illumination point, our system samples multiple locations in parallel, with particular advantages for monitoring fast dynamic processes. We compared methods of patterned illumination and confocal image reconstruction by characterizing the point spread function, contrast, and intensity of imaged objects. Sample 3D reconstructions include a diatom and a Golgi-stained nerve cell collected in transmission.  相似文献   

19.
Delay‐and‐sum (DAS) is one of the most common algorithms used to construct the photoacoustic images due to its low complexity. However, it results in images with high sidelobes and low resolution. Delay‐and‐standard‐deviation (DASD) weighting factor can improve the contrast of the images compared to DAS. However, it still suffers from high sidelobes. In this work, a new weighting factor, named delay‐multiply‐and‐standard‐deviation (DMASD) is introduced to enhance the contrast of the reconstructed images compared to other mentioned methods. In the proposed method, the SD of the mutual multiplied delayed signals are calculated, normalized and multiplied to DAS beamformed data. The results show that DMASD improves the signal‐to‐noise‐ratio about 19.29 and 7.3 dB compared to DAS and DASD, respectively, for in vivo imaging of the sentinel lymph node. Moreover, the contrast ratio is improved by the DMASD about 23.61 and 10.81 dB compared to DAS and DASD, respectively.   相似文献   

20.
The basic idea of X-ray dark-field imaging (XDFI), first presented in 2000, was based on the concepts used in an X-ray interferometer. In this article, we review 20 years of developments in our theoretical understanding, scientific instrumentation, and experimental demonstration of XDFI and its applications to medical imaging. We first describe the concepts underlying XDFI that are responsible for imparting phase contrast information in projection X-ray images. We then review the algorithms that can convert these projection phase images into three-dimensional tomographic slices. Various implementations of computed tomography reconstructions algorithms for XDFI data are discussed. The next four sections describe and illustrate potential applications of XDFI in pathology, musculoskeletal imaging, oncologic imaging, and neuroimaging. The sample applications that are presented illustrate potential use scenarios for XDFI in histopathology and other clinical applications. Finally, the last section presents future perspectives and potential technical developments that can make XDFI an even more powerful tool.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号