首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this study, we made use of dual‐wavelength laser speckle imaging (DW‐LSI) to assess cerebral blood flow (CBF) in the BTBR‐genetic mouse model of autism spectrum disorder, as well as control (C57Bl/6J) mice. Since the deficits in social behavior demonstrated by BTBR mice are attributed to changes in neural tissue structure and function, we postulated that these changes can be detected optically using DW‐LSI. BTBR mice demonstrated reductions in both CBF and cerebral oxygen metabolism (CMRO2), as suggested by studies using conventional neuroimaging technologies to reflect impaired neuronal activation and cognitive function. To validate the monitoring of CBF by DW‐LSI, measurements with laser Doppler flowmetry (LDF) were also performed which confirmed the lowered CBF in the autistic‐like group. Furthermore, we found in vivo cortical CBF measurements to predict the rate of hippocampal neurogenesis, measured ex vivo by the number of neurons expressing doublecortin or the cellular proliferation marker Ki‐67 in the dentate gyrus, with a strong positive correlation between CBF and neurogenesis markers (Pearson, r = 0.78; 0.9, respectively). These novel findings identifying cortical CBF as a predictive parameter of hippocampal neurogenesis highlight the power and flexibility of the DW‐LSI and LDF setups for studying neurogenesis trends under normal and pathological conditions.   相似文献   

2.
Cerebral malaria (CM) is a severe complication of Plasmodium falciparum infection associated with impaired cerebral blood flow. Visualization of the eye vasculature, which is embryologically derived from that of the brain, is used clinically to diagnose the syndrome. Here, we introduce camera‐phone laser speckle imaging as a new tool for in vivo, noncontact two‐dimensional mapping of blood flow dynamics in the experimental cerebral malaria (ECM) murine model of Plasmodium berghei ANKA. In a longitudinal study, we show that the camera‐phone imager can detect an overall decrease in the retinal blood‐flow‐speed (BFS) as ECM develops in P. berghei ANKA infected mice, with no similar change observed in uninfected control mice or mice infected with a non‐ECM inducing strain (P. berghei NK65). Furthermore, by analyzing relative alterations in the BFS of individual retinal vessels during the progression of ECM, we illustrate the strength of our imager in identifying different BFS‐change heterogeneities in the retinas of ECM and uninfected mice. The technique creates new possibilities for objective investigations into the diagnosis and pathogenesis of CM noninvasively through the eye. The camera‐phone laser speckle imager along with measured spatial blood perfusion maps of the retina of a mouse infected with P. berghei ANKA—a fatal ECM model—on different days during the progression of the infection (top, day 3 after infection; middle, day 5 after infection; and bottom, day 7 after infection).   相似文献   

3.
The impairments of cerebral blood flow microcirculation brought on by cardiac and respiratory arrest were assessed with multi-modal diagnostic facilities, utilising laser speckle contrast imaging, fluorescence spectroscopy and diffuse reflectance spectroscopy. The results of laser speckle contrast imaging show a notable reduction of cerebral blood flow in small and medium size vessels during a few minutes of respiratory arrest, while the same effect was observed in large sinuses and their branches during the circulatory cessation. Concurrently, the redox ratio assessed with fluorescence spectroscopy indicates progressing hypoxia, NADH accumulation and increase of FAD consumption. The results of diffuse reflectance spectra measurements display a more rapid grow of the perfusion of deoxygenated blood in case of circulatory impairment. In addition, consequent histopathological analysis performed by using new tissue staining procedure developed in-house. It shows notably higher reduction of size of the neurons due to their wrinkling within brain tissues influenced by circulation impair. Whereas, the brain tissues altered with the respiratory arrest demonstrate focal perivascular oedema and mild hypoxic changes of neuronal morphology. Thus, the study suggests that consequences of a cessation of cerebral blood flow become more dramatic and dangerous compare to respiratory arrest.  相似文献   

4.
Laser speckle contrast imaging (LSCI) is used in clinical research to dynamically image blood flow. One drawback is its susceptibility to movement artifacts. We demonstrate a new, simple method to correct motion artifacts in LSCI signals measured in awake mice with cranial windows during sensory stimulation. The principle is to identify a region in the image in which speckle contrast (SC) is independent of blood flow and only varies with animal movement, then to regress out this signal from the data. We show that (1) the regressed signal correlates well with mouse head movement, (2) the corrected signal correlates better with independently measured blood volume and (3) it has a (59 ± 6)% higher signal-to-noise ratio. Compared to three alternative correction methods, ours has the best performance. Regressing out flow-independent global variations in SC is a simple and accessible way to improve the quality of LSCI measurements.  相似文献   

5.
Laser speckle contrast imaging (LSCI) is a full‐field optical imaging method for monitoring blood flow and vascular morphology with high spatiotemporal resolution. However, due to the limited depth of field of optical system, it is difficult to capture a clear blood flow image with all blood vessels focused, especially for the non‐planar biological tissues. In this study, a multi‐focus image fusion method based on contourlet transform is introduced to reduce the misfocus effects in LSCI. The experimental results suggest that this method can provide an all‐in‐focus blood flow image, which is convenient to observe the blood vessels.   相似文献   

6.
目的:研究大鼠脑缺血/再灌注过程中血流量及与脑组织水含量变化的趋势。方法:选取5只成年SD雄性大鼠(n=5),参照改良Zea-Longa线栓法制备大鼠大脑中动脉缺血/再灌注模型,2 h后拔出线栓。利用PeriCam PSI血流灌注成像系统实时监测大鼠在缺血前及缺血5 min、30 min、1 h、2 h、再灌注5 min、30 min、1 h、2 h、4 h、6 h及24 h的血流灌注量,记录在ROI(感兴趣区)测量的数值。再选取15只成年SD雄性大鼠,分为Control组、缺血2 h、再灌注30 min、4 h及24 h组(n=3)。正常组不做任何处理,实验组按上述线栓法制备MCAO模型。取新鲜脑组织用干湿重法测定其左、右半球的水含量。结果:栓塞时缺血侧血流量逐渐下降,缺血2 h下降最低(P<0.05);再灌注早期血流量恢复较大(P<0.05),30 min时显著下降(P<0.05),4 h明显上升(P<0.05),24 h再次上升(P<0.05)但低于缺血前血流量(P>0.05)。脑组织水含量测量,缺血2 h组和再灌注30 min组与正常组无明显差异(P>0.05);再灌4 h组和再灌24 h组明显增高(P<0.05),且再灌24 h组明显高于再灌4 h组(P<0.05)。结论:大鼠脑缺血/再灌注过程中血流量和脑组织中水含量的变化存在一定的规律,且脑组织中水含量与再灌注过程中血流量的变化有一定关系。  相似文献   

7.
A critical link exists between pathological changes of cerebral vasculature and diseases affecting brain function. Microscopic techniques have played an indispensable role in the study of neurovascular anatomy and functions. Yet, investigations are often hindered by suboptimal trade‐offs between the spatiotemporal resolution, field‐of‐view (FOV) and type of contrast offered by the existing optical microscopy techniques. We present a hybrid dual‐wavelength optoacoustic (OA) biomicroscope capable of rapid transcranial visualization of large‐scale cerebral vascular networks. The system offers 3‐dimensional views of the morphology and oxygenation status of the cerebral vasculature with single capillary resolution and a FOV exceeding 6 × 8 mm2, thus covering the entire cortical vasculature in mice. The large‐scale OA imaging capacity is complemented by simultaneously acquired pulse‐echo ultrasound (US) biomicroscopy scans of the mouse skull. The new approach holds great potential to provide better insights into cerebrovascular function and facilitate efficient studies into neurological and vascular abnormalities of the brain.   相似文献   

8.
目的:观察实验性大鼠脑损伤后不同时相点大脑皮层体感诱发电位(sensorysomaticevoked potentials,ssep)和局部血流量(regional cerebral blood flow,rCBF)的变化。方法:用流体冲击装置制作中度脑损伤模型SYD4200型神经诱发电位诊断系统监测皮层体感诱发电位,氢清除测定大脑局部血流量。结果:中度脑损伤后rCBF明显低于伤前和正常对照组;大脑皮层体感诱发电位的潜伏期明显延长。结论:SEP的变化与脑血流量有着一定的关系,一定程度上SEP的变化可反映脑损伤后血流量的变化。  相似文献   

9.
10.
In this report, an integrated optical platform based on spatial illumination together with laser speckle contrast technique was utilized to measure multiple parameters in live tissue including absorption, scattering, saturation, composition, metabolism, and blood flow. Measurements in three models of tissue injury including drug toxicity, artery occlusion, and acute hyperglycemia were used to test the efficacy of this system. With this hybrid apparatus, a series of structured light patterns at low and high spatial frequencies are projected onto the tissue surface and diffuse reflected light is captured by a CCD camera. A six position filter wheel, equipped with four bandpass filters centered at wavelengths of 650, 690, 800 and 880 nm is placed in front of the camera. Then, light patterns are blocked and a laser source at 650 nm illuminates the tissue while the diffusely reflected light is captured by the camera through the two remaining open holes in the wheel. In this manner, near‐infrared (NIR) and laser speckle images are captured and stored together in the computer for off‐line processing to reconstruct the tissue's properties. Spatial patterns are used to differentiate the effects of tissue scattering from those of absorption, allowing accurate quantification of tissue hemodynamics and morphology, while a coherent light source is used to study blood flow changes, a feature which cannot be measured with the NIR structured light. This combined configuration utilizes the strengths of each system in a complementary way, thus collecting a larger range of sample properties. In addition, once the flow and hemodynamics are measured, tissue oxygen metabolism can be calculated, a property which cannot be measured independently. Therefore, this merged platform can be considered a multiparameter wide‐field imaging and spectroscopy modality. Overall, experiments demonstrate the capability of this spatially coregistered imaging setup to provide complementary, useful information of various tissue metrics in a simple and noncontact manner, making it attractive for use in a variety of biomedical applications.  相似文献   

11.
We adapted and tested an innovative noncontact speckle contrast diffuse correlation tomography (scDCT) system for 3D imaging of cerebral blood flow (CBF) variations in perinatal disease models utilizing neonatal piglets, which closely resemble human neonates. CBF variations were concurrently measured by the scDCT and an established diffuse correlation spectroscopy (DCS) during global ischemia, intraventricular hemorrhage, and asphyxia; significant correlations were observed. Moreover, CBF variations associated reasonably with vital pathophysiological changes. In contrast to DCS measurements of mixed signals from local scalp, skull and brain, scDCT generates 3D images of CBF distributions at prescribed depths within the head, thus enabling specific determination of regional cerebral ischemia. With further optimization and validation in animals and human neonates, scDCT has the potential to be a noninvasive imaging tool for both basic neuroscience research in laboratories and clinical applications in neonatal intensive care units.  相似文献   

12.
Receptor concentration imaging (RCI) with targeted‐untargeted optical dye pairs has enabled in vivo immunohistochemistry analysis in preclinical subcutaneous tumors. Successful application of RCI to fluorescence guided resection (FGR), so that quantitative molecular imaging of tumor‐specific receptors could be performed in situ, would have a high impact. However, assumptions of pharmacokinetics, permeability and retention, as well as the lack of a suitable reference region limit the potential for RCI in human neurosurgery. In this study, an arterial input graphic analysis (AIGA) method is presented which is enabled by independent component analysis (ICA). The percent difference in arterial concentration between the image‐derived arterial input function (AIFICA) and that obtained by an invasive method (ICACAR) was 2.0 ± 2.7% during the first hour of circulation of a targeted‐untargeted dye pair in mice. Estimates of distribution volume and receptor concentration in tumor bearing mice (n = 5) recovered using the AIGA technique did not differ significantly from values obtained using invasive AIF measurements (p = 0.12). The AIGA method, enabled by the subject‐specific AIFICA, was also applied in a rat orthotopic model of U‐251 glioblastoma to obtain the first reported receptor concentration and distribution volume maps during open craniotomy.

  相似文献   


13.
Quantitative autoradiography of [14C]deoxyglucose, [14C]iodoantipyrine, and [14C]leucine was used to estimate regional cerebral glucose metabolism, cerebral blood flow, and cerebral protein synthesis, respectively, in rats during morphine dependence and withdrawal. Glucose metabolism was elevated in 19 of 26 selected brain regions; the elevations in glucose metabolism were similar when data were expressed as either optical density ratios or as calculated rate values of mol/100 gm/min. Restraining the rats produced heterogeneous effects on glucose metabolism during morphine withdrawal (MW). Neither estimated cerebral blood flow nor cerebral protein synthesis were affected by morphine and/or naloxone treatments in either naive or morphine-dependent rats. The data demonstrate that changes in regional cerebral glucose utilization occur independently of blood flow changes and exclude the possibility that regional changes in glucose utilization occur as a consequence of large regional changes in protein synthesis rates in brain. These data confirm the utility of 2-deoxyglucose measures of MW as objective biochemical indices of opiate agonist and antagonist effects in vivo.  相似文献   

14.
Photoplethysmography is a well‐established technique for the noninvasive measurement of blood pulsation. However, photoplethysmographic devices typically need to be in contact with the surface of the tissue and provide data from a single contact point. Extensions of conventional photoplethysmography to measurements over a wide field‐of‐view exist, but require advanced signal processing due to the low signal‐to‐noise‐ratio of the photoplethysmograms. Here, we present a noncontact method based on temporal sampling of time‐integrated speckle using a camera‐phone for noninvasive, widefield measurements of physiological parameters across the human fingertip including blood pulsation and resting heart‐rate frequency. The results show that precise estimation of these parameters with high spatial resolution is enabled by measuring the local temporal variation of speckle patterns of backscattered light from subcutaneous skin, thereby opening up the possibility for accurate high resolution blood pulsation imaging on a camera‐phone.

Camera‐phone laser speckle imager along with measured relative blood perfusion maps of a fingertip showing skin perfusion response to a pulse pressure applied to the upper arm. The figure is for illustration only; the imager was stabilized on a stand throughout the experiments.  相似文献   


15.
We present a hybrid dual‐wavelength optoacoustic and ultrasound bio‐microscope capable of rapid transcranial visualization of morphology and oxygenation status of large‐scale cerebral vascular networks. Imaging of entire cortical vasculature in mice is achieved with single capillary resolution and complemented by simultaneously acquired pulse‐echo ultrasound microscopy scans of the mouse skull. The new approach holds potential to facilitate studies into neurological and vascular abnormalities of the brain. Further details can be found in the article by Johannes Rebling, Héctor Estrada, Sven Gottschalk, et al. ( e201800057 ).

  相似文献   


16.
Changes in electroencephalogams (EEG) and cerebral blood flow were examined in carp immobilized with a muscle relaxant during 60 min hypoxia (water Po 2 of approximately 20 mmHg) and subsequent 30 min normoxia. The amplitude of EEG waves recorded from the telencephalon decreased gradually but slightly with the progression of hypoxia, whereas the telencephalic blood flow increased mainly due to an increased blood velocity. These findings suggested that cerebral activity during hypoxia was compensated to some degree by increased cerebral blood flow. However, carp showed large variations in the patterns of EEG responses and cerebral blood flow.  相似文献   

17.
Fabry disease is an X-linked lysosomal disorder characterized by deficient alpha-galactosidase A activity and intracellular accumulations of glycosphingolipids, mainly globotriaosylceramide (Gb3). Clinically, patients occasionally present CNS dysfunction. To examine the pathophysiology underlying brain dysfunction, we examined glucose utilization (CMR(glc)) and cerebral blood flow (CBF) globally and locally in 18 brain structures in the alpha-galactosidase A gene knockout mouse. Global CMR(glc) was statistically significantly reduced by 22% in Fabry mice (p < 0.01). All 18 structures showed decreases in local CMR(glc) ranging from 14% to 33%. The decreases in all structures of the diencephalon, caudate-putamen, brain stem, and cerebellar cortex were statistically significant (p < 0.05). Global cerebral blood flow (CBF) and local CBF measured in the same 18 structures were lower in Fabry mice than in control mice, but none statistically significantly. Histological examination of brain revealed no cerebral infarcts but abundant Gb3 deposits in the walls of the cerebral vessels with neuronal deposits localized to the medulla oblongata. These results indicate an impairment in cerebral energy metabolism in the Fabry mice, but one not necessarily due to circulatory insufficiency.  相似文献   

18.
Prenatal ethanol exposure (PEE) can lead to structural and functional abnormalities in fetal brain. Although neural developmental deficits due to PEE have been recognized, the immediate effects of PEE on fetal brain vasculature and hemodynamics remain poorly understood. One of the major obstacles that preclude the rapid advancement of studies on fetal vascular dynamics is the limitation of the imaging techniques. Thus, a technique for noninvasive in‐vivo imaging of fetal vasculature and hemodynamics is desirable. In this study, we explored the dynamic changes of the vessel dimeter, density and oxygen saturation in fetal brain after acute maternal ethanol exposure in the second‐trimester equivalent murine model using a real‐time photoacoustic tomography system we developed for imaging embryo of small animals. The results indicate a significant decrease in fetal brain vessel diameter, perfusion and oxygen saturation. This work demonstrated that PAT can provide high‐resolution noninvasive imaging ability to monitor fetal vascular dynamics.  相似文献   

19.
Propranolol, a β-adrenergic receptor blocker, is one of the most commonly used prophylactic drugs for migraines. Cortical spreading depression (CSD) is the propagation wave of neuronal excitation along with cerebral blood flow (CBF) changes over the cerebral cortex and has been implicated in the pathological process of migraine auras and its pain response. However, the effect of propranolol on CSD-related CBF changes and behavioral responses remains poorly understood. In this study, we measured CSD-related CBF responses using a micro-device with a green light emitting diode (LED) and micro-complementary-metal-oxide-semiconductor (CMOS) image sensor and evaluated pain-related reduced locomotor activity in mice. An injection of KCl into the visual cortex led to CSD-related CBF changes; however, propranolol prevented the increase in CBF as well as delayed the propagation velocity in KCl-induced CSD. Furthermore, an injection of KCl reduced locomotor activity and induced freezing behavior in awake and freely moving mice, which were prevented by propranolol treatment. These results suggest that the modulation of CSD-related CBF responses by the blockade of β-adrenergic receptor contributes to its prophylactic effects on migraines.  相似文献   

20.
The analysis of structural brain asymmetry has been a focal point in anthropological theories of human brain evolution and the development of lateralized behaviors. While physiological brain asymmetries have been documented for humans and animals presenting with pathological conditions or under certain activation tasks, published studies on baseline asymmetries in healthy individuals have produced conflicting results. We tested for the presence of cerebral blood flow asymmetries in 7 healthy, sedated baboons using positron emission tomography, a method of in vivo autoradiography. Five of the 7 baboons exhibited hemispheric asymmetries in which left-sided flow was significantly greater than right-sided flow. Furthermore, the degree of asymmetry in 8 of 24 brain regions was found to be significantly correlated with age; older individuals exhibited a higher degree of asymmetry than younger individuals. Cerebral blood flow itself was uncorrelated with age, and differences between males and females were not significant.  相似文献   