首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Sub‐picosecond light pulses are used to launch high‐frequency ultrasound in cells. The dual detection of acoustic echoes and of the time‐domain Brillouin scattering allows mapping remotely and in a single run experiment the cell adhesion, thickness, storage modulus and mass density, all with micron resolution. The dual picosecond opto‐acoustic microscope is demonstrated with the multiple imaging of a mitotic macrophage‐like cell. This novel modality is compatible with simultaneous fluorescence imaging. Further details can be found in the article by Liwang Liu, Laurent Plawinski, Marie‐Christine Durrieu, Bertrand Audoin ( e201900045 ).

  相似文献   


2.
A novel capsule optoacoustic endoscopy (COE) system is built which provides high‐quality 360‐degree images of the entire lumen, specifically designed for typical dimensions of human esophagus. The pill‐shaped encapsulated probe consists of a novel and highly sensitive ultrasound transducer fitted with an integrated miniature pre‐amplifier. For the first time, ex vivo volumetric vascular network images to a depth of 2 mm in swine esophageal lining using COE are demonstrated. Further details can be found in the article by Hailong He, Antonios Stylogiannis, Parastoo Afshari, et al. ( e201800439 )

  相似文献   


3.
Optical tissue clearing is a method allowing post‐mortem deep imaging of organs in three dimensions. By optimizing the CUBIC clearing protocol, the authors provide rapid and simple approach to clear the entire adult rat organism within as little as four days, which is accompanied by the variety of its staining and imaging techniques. The image was captured with polarizers and demonstrates transparent rodent heart with thread‐like crystals of clearing reagent. Further details can be found in the article by Pawe? Matryba et al. ( e201700248 ).

  相似文献   


4.
This schematic depicts the classification of multiphoton images with different degrees of HCC differentiation using the VGG‐16 neural network. The convolution layer is further trained based on the original weights. The weights of the fully connected layers are initialized as a random number and the training is restarted to improve its classification accuracy. Further details can be found in the article by Hongxin Lin, Chao Wei, Guangxing Wang, et al. ( e201800435 ).

  相似文献   


5.
Spectra from microscopic tissue sections are strongly distorted by Mie‐type scattering and require correction by the ME‐EMSC algorithm. In the upper right, Mie extinction curves, which are simulated by the ME‐EMSC algorithm, are shown. Two measured spectra are shown in the foreground, a raw spectrum which contains Mie scattering, and the spectrum corrected by the ME‐EMSC algorithm. The cover figure was designed by Dr. Boris Zimmermann. Further details can be found in the article by Johanne H. Solheim, Evgeniy Gunko, Dennis Petersen, et al. ( e201800415 ).

  相似文献   


6.
A novel design of an SRS microscope exploiting spectral pulse shaping allows measurement of fingerprint to CH‐stretch SRS spectra without any modification of the optical setup. High spectral resolution over a broad vibrational range allows label‐free quantitative imaging of biological samples. An exemplary SRS broadband spectrum of lipid droplets in a liver cancer cell is shown in the picture. Further details can be found in the article by Sergey P. Laptenok, Vijayakumar P. Rajamanickam, Luca Genchi, et al. ( e201900028 ).

  相似文献   


7.
Infrared attenuated total reflection spectroscopy is an emerging label‐free method for analyzing the degree of damage in cartilage samples. In the present study, sheep menisci have been characterized after meniscectomy via the variances of relevant biomolecules at the incision surface. Further details can be found in the article by Angela I. López‐Lorente et al. ( e201800429 ).

  相似文献   


8.
Photodynamic inactivation of prions by disulfonated hydroxyaluminum phthalocyanine. Further details can be found in the article by Marie Kostelanska, Jaroslav Freisleben, Zdenka Backovska Hanusova, et al. ( e201800430 ).

  相似文献   


9.
Incorporation of genipin into design of immunoisolation devices is harnessed for in vivo imaging. Using cell‐compatible in situ crosslinking reactions, a fast, efficient and noncytotoxic procedure is shown to maximize fluorescence of microcapsules. By injecting increasing doses of microcapsules in mice, good linearity of signal to microcapsule dose is obtained over several weeks. This allows quantitative assessment of the actual injected dose and monitoring of its position over time, thereby significantly enhancing the efficacy and biosafety of the therapy. Further details can be found in the article by Edorta Santos‐Vizcaino, Henry Haley, Ainhoa Gonzalez‐Pujana, et al. ( e201800170 ).

  相似文献   


10.
Label‐free optical projection tomography technique makes it possible for quantitative whole mouse embryo imaging without any exogenous contrast agent. Further details can be found in the article by Sungbea Ban, Nam Hyun Cho, Eunjung Min, et al. ( e201800481 ).

  相似文献   


11.
A novel, camera phone‐based laser speckle imager creates new possibilities for quantitative and noninvasive investigations into diagnosis and pathogenesis of cerebral malaria through the eye. In a longitudinal study, a camera‐phone imager detected decreased retinal blood flow speed as experimental cerebral malaria developed in a murine model. The device may ultimately permit recognition of the syndrome prior to the onset of clinical symptoms which is not currently possible. Further details can be found in the article by Itay Remer, Lorraine F. Pierre‐Destine, David Tay, Linnie M. Golightly, and Alberto Bilenca ( e201800098 ).

  相似文献   


12.
A catheter‐based OCT system is used in intubated mechanically‐ventilated critical care patients for the in vivo detection of endotracheal tube biofilm formation, which has been linked to ventilator‐associated pneumonia and death. The combination of attenuation coefficient and structural imaging enables longitudinal monitoring of biofilm growth and differentiation from mucus. In contrast to conventional diagnostic procedures, this approach provides effective real‐time bed‐side detection of biofilms. Further details can be found in the article by Roshan Dsouza, Darold R. Spillman Jr., Ronit Barkalifa, et al. ( e201800307 ).

  相似文献   


13.
Thrombosis monitoring in vivo in small animals is of great value in basic research. The aim of this study is to utilize OCT to monitor thrombosis progression in femoral vein of mice from various measurement criteria, and to validate its use in evaluation the efficacy of the antithrombotic drug. The proved capability of obtaining thrombodynamics information in mice model provide valuable use in preclinical studies for anti‐thrombotic drugs development research. Further details can be found in the article by Yao Yu, Menghan Yu, Jian Liu, et al. ( e201900105 ).

  相似文献   


14.
A wearable device based on fiber optic biosensor for high‐precision radial pulse wave monitoring and diagnosis is proposed and demonstrated in this article. Owing to the high sensitivity of the tiny fiber tip with aluminum diaphragm assembled in the sportswristband, weak acoustic signal induced by arterial pulse can be high‐fidelity recovered and then quantitatively analyzed for clinical diagnosis, which is promising in early cardiovascular diseases indicating. Further details can be found in the article by Jingyi Wang, Kewei Liu, Qizhen Sun, et al. ( e201900084 ).

  相似文献   


15.
Cationic gold nanorods stabilized by quaternary ammonium salts (QAS) are a promising tool for photothermal destruction of cancer cells. However, cytotoxicity of the alkanethiol‐QAS limits their medical applications. A novel design of cationic surfactant composed of the quaternary ammonium group and ethylene glycol chain significantly reduces the compound cytotoxicity in the free state while allowing the preparation of stable nanorods with high cellular uptake and lysosomal localization. Further details can be found in the article by Sarka Salajkova, Michal Sramek, David Malinak, et al. ( e201900024 ).

  相似文献   


16.
There is a clinical need in the treatment of atrial fibrillation by radiofrequency ablation to provide lesion set validation. The integration of optical fibers into radiofrequency ablation catheters can address this issue. Thermally‐induced, dynamic changes in tissue diffuse reflectance are measured through transcatheter near‐infrared spectroscopy. A regression model based on spectral features is proposed and utilized to validate the presence of thermal injury, measure lesion depth, and assess gaps. Further details can be found in the article by Rajinder P. Singh‐Moon, Xinwen Yao, Vivek Iyer, et al. ( e201800144 ).

  相似文献   


17.
The nuclei of epithelial cells in stratified squamous epithelia have been reported to be either low scattering or high scattering. Using micro‐optical coherence tomography, we demonstrate that the nuclei are ‘low scattering’ in the core; those previously reported ‘high‐scattering’ signals are likely from the nucleocytoplasmic boundary. Further details can be found in the article by Si Chen, Xinyu Liu, Nanshuo Wang, et al. ( e201900073 ).

  相似文献   


18.
Optimized light delivery allows for single shot whole organ optoacoustic imaging. The authors present an optimized illumination concept for volumetric tomography that utilizes 3D printing in combination with custom‐made optical fiber illumination. The new approach showed a clear advantage over conventional, single‐sided illumination strategies by eliminating the need to correct for illumination variances and resulting in enhancement of the effective field of view, greater penetration depth and significant improvements in the overall image quality. Further details can be found in the article by Benedict Mc Larney, Johannes Rebling, Zhenyue Chen, et al. ( e201800387 )

  相似文献   


19.
A new quantitative phase imaging (QPI) modality, coined multi‐ATOM, can now capture and process enormous amount of quantitative phase single‐cell images (>700,000 cells) at a ultrahigh throughput without compromising sub‐cellular resolution. It could empower label‐free single‐cell analysis where large‐scale and cost‐effective screening is necessary. Further details can be found in the article by Kelvin C. M. Lee, Andy K. S. Lau, Anson H. L. Tang, et al. ( e201800479 ).

  相似文献   


20.
To optimize the resection of gliomas during neurosurgery we present an imaging system capable of wide field fluorescence lifetime mapping with 11 mm field of view and 250 mm working distance. Based on a time of flight dual‐tap CMOS camera and a modulated laser at 405 nm we show unobserved quenching effects in tissue phantoms and demonstrate life‐time imaging on 5‐ALA labeled human ex vivo brain tumor samples. Further details can be found in the article by Mikael T. Erkkilä, Bianca Bauer, Nancy Hecker‐Denschlag, et al. ( e201800378 ).

  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号