首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Photoacoustic computed tomography (PACT) is a non‐invasive imaging technique offering high contrast, high resolution, and deep penetration in biological tissues. We report a PACT system equipped with a high frequency linear transducer array for mapping the microvascular network of a whole mouse brain with the skull intact and studying its hemodynamic activities. The linear array was scanned in the coronal plane to collect data from different angles, and full‐view images were synthesized from the limited‐view images in which vessels were only partially revealed. We investigated spontaneous neural activities in the deep brain by monitoring the concentration of hemoglobin in the blood vessels and observed strong interhemispherical correlations between several chosen functional regions, both in the cortical layer and in the deep regions. We also studied neural activities during an epileptic seizure and observed the epileptic wave spreading around the injection site and the wave propagating in the opposite hemisphere.

  相似文献   


2.
Chicken embryos have been proven to be an attractive vertebrate model for biomedical research. They have helped in making significant contributions for advancements in various fields like developmental biology, cancer research and cardiovascular studies. However, a non‐invasive, label‐free method of imaging live chicken embryo at high resolution still needs to be developed and optimized. In this work, we have shown the potential of photoacoustic tomography (PAT) for imaging live chicken embryos cultured in bioengineered eggshells. Laser pulses at wavelengths of 532 and 740 nm were used for attaining cross‐sectional images of chicken embryos at different developmental stages. Cross‐sections along different depths were imaged to gain knowledge of the relative depth of different vessels and organs. Due to high optical absorption of vasculature and embryonic eye, images with good optical contrast could be acquired using this method. We have thus reported a label‐free method of performing cross‐sectional imaging of chicken embryos at high resolution demonstrating the capacity of PAT as a promising tool for avian embryo imaging.  相似文献   

3.
Photoacoustic microscopy (PAM) provides a fundamentally new tool for a broad range of studies of biological structures and functions. However, the use of PAM has been largely limited to small vertebrates due to the large size/weight and the inconvenience of the equipment. Here, we describe a portable optical‐resolution photoacoustic microscopy (pORPAM) system for 3‐dimensional (3D) imaging of small‐to‐large rodents and humans with a high spatiotemporal resolution and a large field of view. We show extensive applications of pORPAM to multiscale animals including mice and rabbits. In addition, we image the 3D vascular networks of human lips, and demonstrate the feasibility of pORPAM to observe the recovery process of oral ulcer and cancer‐associated capillary loops in human oral cavities. This technology is promising for broad biomedical studies from fundamental biology to clinical diseases.   相似文献   

4.
The rapidly evolving field of photoacoustic tomography utilizes endogenous chromophores to extract both functional and structural information from deep within tissues. It is this power to perform precise quantitative measurements in vivo—with endogenous or exogenous contrastthat makes photoacoustic tomography highly promising for clinical translation in functional brain imaging, early cancer detection, real-time surgical guidance, and the visualization of dynamic drug responses. Considering photoacoustic tomography has benefited from numerous engineering innovations, it is of no surprise that many of photoacoustic tomography’s current cutting-edge developments incorporate advances from the equally novel field of artificial intelligence. More specifically, alongside the growth and prevalence of graphical processing unit capabilities within recent years has emerged an offshoot of artificial intelligence known as deep learning. Rooted in the solid foundation of signal processing, deep learning typically utilizes a method of optimization known as gradient descent to minimize a loss function and update model parameters. There are already a number of innovative efforts in photoacoustic tomography utilizing deep learning techniques for a variety of purposes, including resolution enhancement, reconstruction artifact removal, undersampling correction, and improved quantification. Most of these efforts have proven to be highly promising in addressing long-standing technical obstacles where traditional solutions either completely fail or make only incremental progress. This concise review focuses on the history of applied artificial intelligence in photoacoustic tomography, presents recent advances at this multifaceted intersection of fields, and outlines the most exciting advances that will likely propagate into promising future innovations.  相似文献   

5.
In acoustic‐resolution photoacoustic microscopy (AR‐PAM) systems, the lateral resolution in the focal zone of the ultrasound (US) transducer is determined by the numerical aperture (NA) of the transducer. To have a high lateral resolution, a large NA is used. However, the larger the NA, the smaller the depth of focus [DOF]. As a result, the lateral resolution is deteriorated at depths out of the focal region. The synthetic aperture focusing technique (SAFT) along with a beamformer can be used to improve the resolution outside the focal region. In this work, for image formation in AR‐PAM, we propose the double‐stage delay‐multiply‐and‐sum (DS_DMAS) algorithm to be combined with SAFT. The proposed method is evaluated experimentally using hair targets and in vivo vasculature imaging. It is shown that DS_DMAS provides a higher resolution and contrast compared to other methods. For the B‐mode images obtained using the hair phantom, the proposed method reduces the average noise level for all the depths by about 134%, 57% and 23%, compared to the original low‐ resolution, SAFT+DAS and SAFT+DMAS methods, respectively. All the results indicate that the proposed method can be an appropriate algorithm for image formation in AR‐PAM systems.   相似文献   

6.
Delay‐and‐sum (DAS) is one of the most common algorithms used to construct the photoacoustic images due to its low complexity. However, it results in images with high sidelobes and low resolution. Delay‐and‐standard‐deviation (DASD) weighting factor can improve the contrast of the images compared to DAS. However, it still suffers from high sidelobes. In this work, a new weighting factor, named delay‐multiply‐and‐standard‐deviation (DMASD) is introduced to enhance the contrast of the reconstructed images compared to other mentioned methods. In the proposed method, the SD of the mutual multiplied delayed signals are calculated, normalized and multiplied to DAS beamformed data. The results show that DMASD improves the signal‐to‐noise‐ratio about 19.29 and 7.3 dB compared to DAS and DASD, respectively, for in vivo imaging of the sentinel lymph node. Moreover, the contrast ratio is improved by the DMASD about 23.61 and 10.81 dB compared to DAS and DASD, respectively.   相似文献   

7.
The blood‐brain barrier (BBB) plays a key role in the health of the central nervous system. Opening the BBB is very important for drug delivery to brain tissues to enhance the therapeutic effect on brain diseases. It is necessary to in vivo monitor the BBB permeability for assessing drug release with high resolution; however, an effective method is lacking. In this work, we developed a new method that combined spectral imaging with an optical clearing skull window to in vivo dynamically monitor BBB opening caused by 5‐aminolevulinic acid (5‐ALA)‐mediated photodynamic therapy (PDT), in which the Evans blue dye (EBd) acted as an indicator of the BBB permeability. Using this method, we effectively monitored the cerebrovascular EBd leakage process. Moreover, the analysis of changes in the vascular and extravascular EBd concentrations demonstrated that the PDT‐induced BBB opening exhibited spatiotemporal differences in the cortex. This spectral imaging method based on the optical clearing skull window provides a low‐cost and simply operated tool for in vivo monitoring BBB opening process. This has a high potential for the visualization of drug delivery to the central nervous system. Thus, it is of tremendous significance in brain disease therapy. Monitoring the changes in PDT‐induced BBB permeability by evaluating the EBd concentration using an optical clearing skull window. (A) Entire brains and coronal sections following treatment of PDT with/without an optical clearing skull window after injection of EBd. (B) Typical EBd distribution maps before and after laser irradiation captured by the spectral imaging method. (Colorbar represents the EBd concentration).   相似文献   

8.
Despite the great promise behind the recent introduction of optoacoustic technology into the arsenal of small‐animal neuroimaging methods, a variety of acoustic and light‐related effects introduced by adult murine skull severely compromise the performance of optoacoustics in transcranial imaging. As a result, high‐resolution noninvasive optoacoustic microscopy studies are still limited to a thin layer of pial microvasculature, which can be effectively resolved by tight focusing of the excitation light. We examined a range of distortions introduced by an adult murine skull in transcranial optoacoustic imaging under both acoustically‐ and optically‐determined resolution scenarios. It is shown that strong low‐pass filtering characteristics of the skull may significantly deteriorate the achievable spatial resolution in deep brain imaging where no light focusing is possible. While only brain vasculature with a diameter larger than 60 µm was effectively resolved via transcranial measurements with acoustic resolution, significant improvements are seen through cranial windows and thinned skull experiments.

(a) Experimental setup for hybrid acoustic and optical resolution optoacoustic microscopy. (b) Transcranial scan of an adult mouse brain using the optical resolution mode. Scale bar is 375 µm.  相似文献   


9.
Optical‐resolution photoacoustic microscopy (OR‐PAM) has been shown to be an excellent imaging modality for monitoring and study of tumor microvasculature. However, previous studies focused mainly on the normal tissues and did not quantify the tumor microvasculature. In this study, we present an in vivo OR‐PAM imaging of the melanomas and hepatoma implanted in the mouse ear. We quantify the vessel growth by extracting the skeletons of both dense and thin branches of the tumor microvasculature obtained by Hessian matrix enhancement followed by improved two‐step multistencils fast marching method. Compared with the previous methods of using OR‐PAM for normal tissues, our method was more effective in extracting the binary vascular network in the tumor images and in obtaining the complete and continuous microvascular skeleton maps. Our demonstration of using OR‐PAM in improving microvasculature of tumors and quantification of tumor growth would push deep this technology for the early diagnosis and treatment of cancers.   相似文献   

10.
The investigation of lung dynamics on alveolar scale is crucial for the understanding and treatment of lung diseases, such as acute lung injury and ventilator induced lung injury, and to promote the development of protective ventilation strategies. One approach to this is the establishment of numerical simulations of lung tissue mechanics where detailed knowledge about three‐dimensional alveolar structure changes during the ventilation cycle is required. We suggest four‐dimensional optical coherence tomography (OCT) imaging as a promising modality for visualizing the structural dynamics of single alveoli in subpleural lung tissue with high temporal resolution using a mouse model. A high‐speed OCT setup based on Fourier domain mode locked laser technology facilitated the acquisition of alveolar structures without noticeable motion artifacts at a rate of 17 three‐dimensional stacks per ventilation cycle. The four‐dimensional information, acquired in one single ventilation cycle, allowed calculating the volume‐pressure curve and the alveolar compliance for single alveoli. (© 2013 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

11.
Brain imaging is an important technique in cognitive neuroscience. In this article, we designed a stereotaxic‐apparatus‐compatible photoacoustic microscope for the studies of rat cortical hemodynamics. Compared with existing optical resolution photoacoustic microscopy (ORPAM) systems, the probe owns feature of fast, light and miniature. In this microscope, we integrated a miniaturized ultrasound transducer with a center frequency of 10 MHz to detect photoacoustic signals and a 2‐dimensional (2D) microelectromechanical system (MEMS) scanner to achieve raster scanning of the optical focus. Based on phantom evaluation, this imaging probe has a high lateral resolution of 3.8 μm and an effective imaging domain of 2 × 2 mm2. Different from conventional ORPAMs, combining with standard stereotaxic apparatus enables broad studies of rodent brains without any motion artifact. To show its capability, we successfully captured red blood cell flow in the capillary, monitored the vascular changes during bleeding and blood infusion and visualized cortical hemodynamics induced by middle cerebral artery occlusion.   相似文献   

12.
Prenatal ethanol exposure (PEE) can lead to structural and functional abnormalities in fetal brain. Although neural developmental deficits due to PEE have been recognized, the immediate effects of PEE on fetal brain vasculature and hemodynamics remain poorly understood. One of the major obstacles that preclude the rapid advancement of studies on fetal vascular dynamics is the limitation of the imaging techniques. Thus, a technique for noninvasive in‐vivo imaging of fetal vasculature and hemodynamics is desirable. In this study, we explored the dynamic changes of the vessel dimeter, density and oxygen saturation in fetal brain after acute maternal ethanol exposure in the second‐trimester equivalent murine model using a real‐time photoacoustic tomography system we developed for imaging embryo of small animals. The results indicate a significant decrease in fetal brain vessel diameter, perfusion and oxygen saturation. This work demonstrated that PAT can provide high‐resolution noninvasive imaging ability to monitor fetal vascular dynamics.  相似文献   

13.
We demonstrate an accurate quantitative characterization of absolute two‐ and three‐photon absorption (2PA and 3PA) action cross sections of a genetically encodable fluorescent marker Sypher3s. Both 2PA and 3PA action cross sections of this marker are found to be remarkably high, enabling high‐brightness, cell‐specific two‐ and three‐photon fluorescence brain imaging. Brain imaging experiments on sliced samples of rat's cortical areas are presented to demonstrate these imaging modalities. The 2PA action cross section of Sypher3s is shown to be highly sensitive to the level of pH, enabling pH measurements via a ratiometric readout of the two‐photon fluorescence with two laser excitation wavelengths, thus paving the way toward fast optical pH sensing in deep‐tissue experiments.  相似文献   

14.
Optical‐resolution photoacoustic microscopy (OR‐PAM), which has been widely used and studied as a noninvasive and in vivo imaging technique, can yield high‐resolution and absorption contrast images. Recently, metallic nanoparticles and dyes, such as gold nanoparticles, methylene blue, and indocyanine green, have been used as contrast agents of OR‐PAM. This study demonstrates real‐time functional OR‐PAM images with high‐speed alternating illumination at 2 wavelengths. To generate 2 wavelengths, second harmonic generation at 532 nm with an LBO crystal and a pump wavelength of 1064 nm is applied at a pulse repetition rate of 300 kHz. For alternating illumination, an electro‐optical modulator is used as an optical switch. Therefore, the A‐line rate for the functional image is 150 kHz, which is half of the laser repetition rate. To enable fast signal processing and real‐time displays, parallel signal processing using a graphics processing unit (GPU) is performed. OR‐PAM images of the distribution of blood vessels and gold nanorods in a BALB/c‐nude mouse's ear can be simultaneously obtained with 500 × 500 pixels and real‐time display at 0.49 fps.   相似文献   

15.
A compact high‐speed full‐field optical coherence microscope has been developed for high‐resolution in vivo imaging of biological tissues. The interferometer, in the Linnik configuration, has a size of 11 × 11 × 5 cm3 and a weight of 210 g. Full‐field illumination with low‐coherence light is achieved with a high‐brightness broadband light‐emitting diode. High‐speed full‐field detection is achieved by using part of the image sensor of a high‐dynamic range CMOS camera. En face tomographic images are acquired at a rate of 50 Hz, with an integration time of 0.9 ms. The image spatial resolution is 0.9 μm × 1.2 μm (axial × transverse), over a field of view of 245 × 245 μm2. Images of human skin, revealing in‐depth cellular‐level structures, were obtained in vivo and in real‐time without the need for stabilization of the subject. The system can image larger fields, up to 1 × 1 mm2, but at a reduced depth.   相似文献   

16.
A sensitive, noninvasive method to detect localized prostate cancer, particularly for early detection and repetitive study in patients undergoing active surveillance, remains an unmet need. Here, we propose a molecular photoacoustic (PA) imaging approach by targeting the prostate‐specific membrane antigen (PSMA), which is over‐expressed in the vast majority of prostate cancers. We performed spectroscopic PA imaging in an experimental model of prostate cancer, namely, in immunocompromised mice bearing PSMA+ (PC3 PIP) and PSMA? (PC3 flu) tumors through administration of the known PSMA‐targeted fluorescence agent, YC‐27. Differences in contrast between PSMA+ and isogenic control tumors were observed upon PA imaging, with PSMA+ tumors showing higher contrast in average of 66.07‐fold with 5 mice at the 24‐hour postinjection time points. These results were corroborated using standard near‐infrared fluorescence imaging with YC‐27, and the squared correlation between PA and fluorescence intensities was 0.89. Spectroscopic PA imaging is a new molecular imaging modality with sufficient sensitivity for targeting PSMA in vivo, demonstrating the potential applications for other saturable targets relevant to cancer and other disorders.   相似文献   

17.
Skin carcinoma such as melanoma (MM) and cutaneous squamous cell carcinoma (cSCC) are considered as the highest mortality and the most aggressive skin cancers in dermatology. In view that early diagnosis and treatment can greatly improve the survival rate and life quality of the patients, developing noninvasive and effective evaluation methods is of great significance for the detection and identification of early stage cutaneous cancers. In this article, we propose a hybrid photoacoustic and hyperspectral dual‐modality microscopy to evaluate and differentiate skin carcinoma by structural and multiphysiological parameters. The proposed system's imaging abilities are verified by mimic phantoms and normal mice experiments. Furthermore, in vivo characterization and evaluation results of MM and cSCC mice are obtained successfully, which prove this novel method could be used as a reliable and useful method for skin cancer detection in early stages.  相似文献   

18.
Photoacoustic microscopy (PAM) is an imaging modality well suited to mapping vasculature and other strong absorbers in tissue. However, one of the primary drawbacks to PAM when used for high‐resolution imaging is the relatively poor axial resolution due to the inverse dependence on the transducer bandwidth. While submicron lateral resolution PAM can be achieved by tightly focusing the excitation light, the axial resolution is fundamentally limited to 10s of microns for typical transducer frequencies. Here we present a multiphoton PAM technique called transient absorption ultrasonic microscopy (TAUM), which results in a completely optically resolved voxel with an experimentally measured axial resolution of 1.5 microns. This technique is demonstrated by imaging individual red blood cells in three dimensions in blood smear and ex vivo tissues. To the best of our knowledge, this is the first demonstration of fully resolved, volumetric photoacoustic imaging of erythrocytes. (© 2014 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

19.
Optical‐resolution photoacoustic microscopy (OR‐PAM) has proven useful for anatomical and functional imaging with high spatial resolutions. However, the coherent signal generation and the desired reflection‐mode detection in OR‐PAM can result in a limited detectability of features aligned with the acoustic axis (ie, vertical structures). Here, we investigated the limited‐view phenomenon in OR‐PAM by simulating the generation and propagation of the acoustic pressure waves and determined the key optical parameters affecting the visibility of vertical structures. Proof‐of‐concept numerical experiments were performed with different illumination angles, optical foci and numerical apertures (NA) of the objective lens. The results collectively show that an NA of 0.3 can readily improve the visibility of vertical structures in a typical reflection‐mode OR‐PAM system. This conclusion was confirmed by numerical simulations on the cortical blood vessels in a mouse brain and by experiments in a suture‐cross phantom and in a mouse brain in vivo.   相似文献   

20.
Photoacoustic (PA) imaging breaks the diffusion limit of conventional optical imaging by listening to the PA wave. As a new kind of functional imaging method, it has experienced tremendous growth in research community with wide range of applications. However, it is still an open and fundamental challenge that the conversion efficiency from light to sound based on PA effect is extremely low. The consequence is the poor signal‐to‐noise ratio (SNR) of PA signal especially in scenarios of low laser power and deep penetration. Conventional approach to enhance the SNR of PA signal in these noisy scenarios is data averaging, which is quite time‐consuming. To improve the signal fidelity and imaging speed, an algorithm of using empirical mode decomposition and independent component analysis de‐noising methods in PA imaging is proposed. The simulation and in vivo experimental results show obvious SNR enhancement of the PA signal and image contrast. The proposed method provides the potential to develop real‐time low‐cost PA imaging system with low‐power laser source.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号