首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 506 毫秒
1.
Immunosensors for small analytes have been a great addition to the analytical toolbox due to their high sensitivity and extended analytical range. In these systems the analyte is detected when it competes for binding to the detecting antibody with a tracer compound. In this work we introduce the use of phage particles bearing peptides that mimic the target analyte as surrogates for conventional tracers. As a proof of concept, we developed a magneto-electrochemical immunosensor (EI) for the herbicide molinate and compare its performance with conventional formats. Using the same anti-molinate antibody and phage particles bearing a molinate peptidomimetic, the EI performed with an IC(50) of 0.15 ngmL(-1) (linear range from 4.4 × 10(-3) to 10 ngmL(-1)). Compared to the conventional ELISA, the EI was faster (minutes), performed with a much wider linear range, and the detection limit that was 2500-fold lower. The EI produced consistent measurements and could be successfully used to assay river water samples with excellent recoveries. By using the same EI with a conventional tracer, we found that an important contribution to the gain in sensitivity is due to the filamentous structure of the phage (9 × 1000 nm) which works as a multienzymatic tracer, amplifying the competitive reaction. Since phage-borne peptidomimetics can be selected from phage display libraries in a straightforward systematic manner and their production is simple and inexpensive, they can contribute to facilitate the development of ultrasensitive biosensors.  相似文献   

2.
A stable and sensitive toxin residues immunosensor based on the relaxation of magnetic nanoparticles was developed. The method was performed in one reaction and offered sensitive, fast detection of target toxin residues in water. The target analyte, microcystin-LR (MC-LR) in Tai lake water, competed with the antigens on the surface of the magnetic nanoparticles and then influenced the formation of aggregates of the magnetic nanoparticles. Accordingly, the magnetic relaxation time of the magnetic nanoparticles was changed under the effect of the target analyte. The calibration curve was deduced at different concentrations of the target analyte. The limit of detection (LOD) of MC-LR was 0.6 ng g−1 and the detection range was 1–18 ng g−1. Another important feature of the developed method was the easy operation: only two steps were needed (1) to mix the magnetic nanoparticle solution with the sample solution and (2) read the results through the instrument. Therefore, the developed method may be a useful tool for toxin residues sensing and may find widespread applications.  相似文献   

3.
A sensitive and efficient method was developed for the determination of carvedilol and its metabolites in human urine by gas chromatography-mass spectrometry (GC-MS). Urine samples were hydrolyzed with beta-glucuronidase/arylsulfatase (from Helix pomatia) and the target compounds were extracted with liquid-liquid extraction. The extracts were completely derivatized with MSTFA and MBTFA and analyzed by GC-MS using an Ultra-2 column. The linearity of the assay ranges were 0.75-75 ngmL(-1) for carvedilol and o-desmethyl carvedilol (o-DMC), and 3.0-75 ngmL(-1) for 4-hydroxyphenyl carvedilol (4-HPC) and 5-hydroxyphenyl carvedilol (5-HPC). The absolute recovery of carvedilol and its metabolites added to a blank urine sample was 80.1-97.8%. The limits of detection (LOD) and quantitation (LOQ) of carvedilol and o-DMC were 0.30 and 0.75 ngmL(-1), and its of 4-HPC and 5-HPC were 0.75 and 3.0 ngmL(-1), respectively. The reproducibilities were 1.86-11.5% for the intra-day assay, and 0.70-1.71% for the inter-day assay precision and the degree of inaccuracy was -3.0 to 3.9% at the concentration of 75 ngmL(-1). The proposed GC-MS method was effective for the determination of carvedilol and its three metabolites in human urine.  相似文献   

4.
A label-free multiplexed immunoassay strategy was proposed for the simultaneous detection of two tumor markers, carcinoembryonic antigen (CEA) and α-fetoprotein (AFP). Monoclonal antibody of CEA was co-immobilized with ferrocenecarboxylic acid (FCA) inside the channels of mesoporous silica (MPS) to prepare the label-free probe for CEA. Also, monoclonal antibody of AFP was co-immobilized with horseradish peroxidase (HRP) inside the channels of MPS to prepare the label-free probe for AFP by using o-phenylenediamine (OPD) and H(2)O(2) as the electrochemical substrates. Thus, the multianalyte immunosensor was constructed by coating the probes of CEA and AFP respectively onto the different areas of indium-tin oxide (ITO) electrode. When the immunosensor was incubated with sample antigens, CEA and AFP antigens were introduced into the mesopores of MPS after the immunoassay reaction. Because all of the Si-OH groups on the external surface of MPS were blocked with Si(CH(3))(3), the proteins and substrates were limited to be embedded on the internal pore walls. Therefore, the electric response transfer was confined inside the pore channels. The nonconductive immunoconjugates blocked the electron transfer and the peak responses changed on the corresponding surface respectively. Then, the simultaneous detection of CEA and AFP achieved. The linear ranges of CEA and AFP were 0.5-45ngmL(-1) and 1-90ngmL(-1) with the detection limits of 0.2ngmL(-1) and 0.5ngmL(-1) (S/N=3), respectively. The fabricated immunosensor shows appropriate sensitivity and offers an alternative to the multianalyte detection of antigens or other bioactive molecules.  相似文献   

5.
A generic, fast, sensitive and new type of flow immunosensor has been developed. The basis is a monolithic porous poly(glycidyl methacrylate-co-trimethylolpropane trimethacrylate) polymer disc modified with protein G, placed in a fountain type flow cell compartment, in close proximity to a photomultiplier tube (PMT). Analyte and HRP labelled analyte derivative (tracer) compete for anti-analyte antibody binding sites. The mixture is then injected into the flow immunosensor system where the formed analyte- and tracer-antibody complexes are trapped by the monolithic protein G disc. The amount of bound tracer, inversely related to the concentration of analyte in the sample, is determined in a second step by injection of luminol, p-iodophenol and H2O2, generating enhanced chemiluminescence (CL) with horseradish peroxidase (HRP). A third and final step is need for regeneration of the protein G disc so that a new analysis cycle can take place. The performance of the disc immunosensor system was compared with a one step continuous flow injection immunoassay (FIIA) system, using the same reagents and a protein G column, in terms of assay sensitivity and influence of matrix effects from various water samples (millipore-, tap- and surface water). The detection limit for the analyte atrazine in PBS and surface water (SW) was 0.208 +/- 0.004 microg l(-1) (PBS) and 0.59 +/- 0.120 microg l(-1) (SW) for the FIIA and 0.033 +/- 0.003 microg l(-1) (PBS) and 0.038+/-0.003 microg l(-1) (SW) for the disc immunosensor. Statistical comparison of the two systems shows that the disc immunosensor results were significantly less influenced by the sample matrix, which is explained by the fact that the sample in the FIIA arrives simultaneously with the matrix to the detector, whereas these are separated in time in the disc immunosensor system.  相似文献   

6.
A new "signal-on" aptasensor for ultrasensitive detection of Ochratoxin A (OTA) in wheat starch was developed based on exonuclease-catalyzed target recycling. To construct the aptasensor, a ferrocene (Fc) labeled probe DNA (S1) was immobilized on a gold electrode (GE) via Au-S bonding for the following hybridization with the complementary OTA aptamer, with the labeled Fc on S1 far from the GE surface. In the presence of analyte OTA, the formation of aptamer-OTA complex would result in not only the dissociation of aptamer from the double-strand DNA but also the transformation of the probe DNA into a hairpin structure. Subsequently, the OTA could be liberated from the aptamer-OTA complex for analyte recycling due to the employment of exonuclease, which is a single-stranded DNA specific exonuclease to selectively digest the appointed DNA (aptamer). Owing to the labeled Fc in close proximity to the electrode surface caused by the formation of the hairpin DNA and to the analyte recycling, differential pulse voltammetry (DPV) signal could be produced with enhanced signal amplification. Based on this strategy, an ultrasensitive aptasensor for the detection of OTA could be exhibited with a wide linear range of 0.005-10.0ngmL(-1) with a low detection limit (LOD) of 1.0pgmL(-1) OTA (at 3σ). The fabricated biosensor was then applied for the measurement of OTA in real wheat starch sample and validated by ELISA method.  相似文献   

7.
In order to develop facile, fast and sensitive detection methods for endocrine-disrupting chemicals (EDCs), we described a sensitive biosensing system involving magnetic relaxation switch, based on the assembly of cross-linked superparamagnetic iron oxide (CLIO) nanoparticles induced by the antigen-antibody biorecognition. The design of smart CLIO-based superparamagnetic iron oxide nanoparticles and antigen-OVA was described for the detection of bisphenol A [2,2-bis (4-hydroxyphenol) propane (BPA)]. The addition of BPA to the rapid magnetic relaxation switch immunosensor led to transverse relaxation time (T2) shortening compared to a blank control as shown by NMR relaxometry measurements. This process was also applied to the rapid and facile determination of concentrations of BPA in drinking water (tap water). Good linearity for all calibration curves was obtained, and the limit of detection (LOD) for BPA was 0.4 ng/mL in tap water.  相似文献   

8.
A novel enzyme-free sandwich electrochemical immunoassay with an ultrahigh sensitivity was developed for detection of alpha-fetoprotein (AFP, as a model analyte) using carbon nanotube-enriched gold nanoparticles (CNT-AuNPs) as nanolabels/nanocatalysts on anti-AFP/glutaraldehyde/thionine-modified glassy carbon electrodes (GCEs). The assays were carried out in a pH 8.0 acetic acid-buffered solution containing 6 mM p-nitrophenol (NP) and 6mM NaBH(4) after the formation of the sandwich-type immunocomplex. Initially, the NP molecules were reduced to p-aminophenol (AP) by the catalysis of the immobilized gold-nanoparticle labels on the CNT-AuNPs with the aid of NaBH(4), then the generated AP molecules were electrochemically oxidized to p-quinone imine (QI) by an electron mediator of thionine, and then the oxidized QI molecules were reduced back to APs by NaBH(4). The redox cycling of AP and QI continuously increased the signaling, leading to a high sensitivity. Compared with individual gold-nanoparticle labels, the immunosensor using CNT-AuNPs as labels displayed a wider linear range of 8.0×10(-7)-2.0×10(2) ng/mL with a lower detection limit (LOD) of 0.8 fg/mL AFP at a signal-to-noise ratio of 3, which was lower 6 orders than that of commercially available ELISA. Intra-and inter-assay coefficients of variation were below 10%. In addition, the assay was evaluated with clinical serum samples, and no significant differences at the 5% confidence level were encountered in the analysis of real samples between the proposed immunoassay and commercially available Roche 2010 Electrochemiluminescent Automatic Analyzer for determination of AFP.  相似文献   

9.
An amperometric immunosensor for polycyclic aromatic hydrocarbons (PAHs) was developed. The immunosensor was based on disposable screen-printed carbon electrodes. The coating antigen used was phenanthrene-9-carboxaldehyde coupled to bovine serum albumin (BSA) via adipic acid dihydrazide. Antibodies were monoclonal mouse anti-phenanthrene. The enzyme alkaline phosphatase (AP) was used in combination with the substrate p-aminophenyl phosphate (pAPP) for detection at +300 mV (vs. Ag/AgCl). Various assay types were compared. Good results were achieved with an indirect co-exposure competition assay with a LOD of 0.8 ng/ml (800 ppt) and an IC(50) of 7.1 ng/ml (7.1 ppb) for phenanthrene. An indirect competition assay could detect phenanthrene with a LOD of 2 ng/ml (IC(50): 15 ng/ml) and an indirect displacement assay with a LOD of 2 ng/ml (IC(50): 11 ng/ml) at a 5 microl surface coating of 8.8 microg/ml phenanthrene-BSA conjugate. A coating concentration of 2.2 microg/ml allowed detection with a LOD of 0.25 ng/ml (250 ppt) with the indirect competition assay. The influence of the coating concentration on the sensor performance was investigated. Cross-reactivities were tested for 16 important PAHs. Anthracene and chrysene showed strong cross-reactivity, whereas benzo[g,h,i]perylene and dibenzo[a,h]anthracene showed no cross-reactivity.  相似文献   

10.
A SPR-based immunosensor for the detection of isoproturon   总被引:1,自引:0,他引:1  
The proof of principle of a reusable surface plasmon resonance (SPR)-based immunosensor for the monitoring of isoproturon (IPU), a selective and systemic herbicide, is presented. The detecting rat monoclonal anti-isoproturon antibody (mAb IOC 7E1) was reversibly immobilized through the use of a capture mouse anti-rat (kappa-chain) monoclonal antibody (mAb TIB 172), which was covalently immobilized on the sensor chip surface. Such strategy features a controlled binding of the captured detecting antibody as well as facilitates the surface regeneration. The capture of the anti-IPU mAb by the antibody (TIB 172) coated sensor surface could be carried out up to 120 times (immobilization/regeneration cycles) without any evidence of activity loss. With a high test midpoint and a low associated SPR signal, the direct detection format was shown to be unsuitable for the routine analysis of isoproturon. However, the limit of detection (LOD) could be easily enhanced by using a strategy based on a surface competition assay, which improved all immunosensor parameters. Moreover, the sensitivity and working range of the indirect format were found to be dependent on the surface density of the anti-IPU mAb IOC 7E1. As expected for competitive formats, the lowest surface coverage (0.5 ng/mm(2)) allowed a lower detection of the herbicide isoproturon with a calculated LOD of 0.1 microg/l, an IC(50) (50% inhibition) of 5.3+/-0.6 microg/l, and a working range (20-80% inhibition) of 1.3-16.3 microg/l.  相似文献   

11.
Zhu Y  Qu C  Kuang H  Xu L  Liu L  Hua Y  Wang L  Xu C 《Biosensors & bioelectronics》2011,26(11):4387-4392
In this work, we report on the application of versatile gold nanorods (GNRs) in optical sensors for the detection of antibiotics. The target analyte, Gentamicin (GM) and ovalbumin (OVA)-antigen-modified GNRs together competed with antibody-modified GNRs, then influenced the formation of side-by-side aggregates of the GNRs by antibody-antigen interactions. Accordingly, the UV-vis absorption intensity of the side-by-side aggregates was changed in the presence of the target analyte. This assay allowed the selective determination of GM in the range of 0.1-20 ng/mL, and the limit of detection (LOD) of GM was 0.05 ng/mL. Furthermore, compared with the traditional plate-based immunoassay, the developed method was easy to perform without washing cycles and the results could be read as soon as the nanoprobe-analyte incubation was complete. Therefore, the developed method could be a promising tool for the detection of antibiotic residues.  相似文献   

12.
A non-enzymatic approach to signal amplification has practical advantages over conventional target amplification methods. We have designed a simple, cost-efficient signal amplification system that can be used to enhance the detection of nucleic acids or protein. The signal amplification process requires initial capture of analyte by a specific probe, which, depending on the analyte, can be an oligomer or an antibody. Once the analyte is captured, amplification moieties are applied to significantly enhance the sensitivity of analyte detection. Nucleic acid amplification is typically greater than 1000-fold, increasing the sensitivity of target detection to less than 1 amol/100 microL. This amplification strategy presents a very flexible system with components that are easily altered to accommodate diverse assay requirements.  相似文献   

13.
In this paper, a simple, easily-operated and enzyme-amplified fluorescence immunoassay method using magnetic particles for the detection of antibody against Actinobacillus pleuropneumoniae (APP) has been presented. The A protein of APP Repeats-in-Toxin IV (ApxIVA) with high specificity to the APP species was immobilized onto the magnetic bead surfaces. Horseradish peroxidase (HRP), which can catalyze the substrate 4-hydroxyphenylacetic acid (p-HPA), generating fluorescent bi-p, p'-hydroxyphenylacetic acid (DBDA), was selected as an enzymatic-amplified tracer. The ApxIVA antibody was detected for the presence of APP infection by measuring the fluorescence intensity of DBDA. Under optimal conditions, the calibration plot obtained for standard positive serum was approximately linear within the dilution range 1:160-1:5120. The limit of detection (LOD) for the assay was 1:10240, considerably lower than that of ApxIVA-ELISA (1:320) (S/N=3). A series of repeatability measurements of using 1:320-fold diluted standard positive serum gave reproducible results with a relative standard deviation (RSD) of 4.8% (n=11). The ability of the immunosensor to analyze clinical samples was tested on porcine sera. The immunosensor yielded an efficiency of 89.7%, sensitivity of 90.9% and specificity of 89.3% compared with ApxIVA-ELISA.  相似文献   

14.
A novel label-free voltammetric immunosensor for sensitive detection of β-lactoglobulin using graphene modified screen printed electrodes has been developed. The derivatization of the graphene electrode surface was achieved by electrochemical reduction of in situ generated 4-nitrophenyl diazonium cations in aqueous acidic solution, followed by electrochemical reduction of the terminal nitro groups to amines. The electrochemical modification protocol was optimized in order to generate monolayer of nitrophenyl groups on the graphene surface without complete passivation of the electrode. Unlike the reported method for graphene functionalization, we demonstrated here the ability of the electrografting of aryl diazonium salt to attach an organic film to the graphene surface in a controlled manner by choosing the suitable grafting protocol. Next, the amine groups on the graphene surface were activated using glutaraldehyde and used for the covalent immobilization of β-lactoglobulin antibodies. Cyclic and differential pulse voltammetry carried out in an aqueous solution containing [Fe(CN)(6)](3-/4-) redox pair have been used for the immunosensor characterization. The results demonstrated that the DPV reduction peak current of [Fe(CN)(6)](3-/4-) decreased linearly with increasing the concentration of β-lactoglobulin due to the formation of antibody-antigen complex on the modified electrode surface. The immunosensor obtained using this novel approach enabled a detection limit of 0.85pgmL(-1) and a dynamic range from 1pgmL(-1) to 100ngmL(-1) of β-lactoglobulin in PBS buffer. In addition, the immunosensor evaluated in different samples including cake, cheese snacks, a sweet biscuit, showing excellent correlation with the results obtained from commercially enzyme-linked immunosorbent assay (ELISA) method.  相似文献   

15.
A novel analytical immunosensor array, based on a microtiter plate coupled to a multichannel electrochemical detection (MED) system using the intermittent pulse amperometry (IPA) technique, is proposed for the detection of aflatoxin B1 (AFB1). In the present work, the electrochemical behaviour and electroanalytical performance of the thick-film carbon sensors (also designated as screen-printed electrodes) incorporated in the multichannel electrochemical plate were first evaluated. Then the 96-well screen-printed microplate was modified in accord with a competitive indirect enzyme-linked immunoassay (ELISA) format for aflatoxin B1 detection. The measurements were performed using both spectrophotometric and electrochemical procedures and the results of the calibration curves, detection limit (LOD), sensitivity and reproducibility of the respective assay systems were evaluated. The immunoassay was then applied for analysis of corn samples spiked with AFB1 before and after the extraction treatment, in order to study the extraction efficiency and the matrix effect, respectively. These studies have shown that using this system, AFB1 can be measured at a level of 30 pg/mL and with a working range between 0.05 and 2 ng/mL. Good recoveries (103+/-8%) were obtained, demonstrating the suitability of the proposed assay for accurate determination of the AFB1 concentration in corn samples. The specificity of the assay was assessed by studying the cross-reactivity of PAb relative to AFB1. The results indicated that the PAb could readily distinguish AFB1 from other aflatoxins, with the exception for AFG1.  相似文献   

16.
An indirect immunoassay format with human growth hormone (hGH) immobilized on the self-assembled monolayer (SAM) modified surface plasmon resonance (SPR) chip has been shown to detect specific anti-hGH antibodies using the combination of three different physical phenomena in the same channel of the SPR analyzer. For the enhancement of analytical signal and sensitivity of the immunosensor horseradish peroxidase (HRP) labeled secondary antibodies, specifically interacting with the formed immune complexes, were used. The electroassisted chemiluminescence (ECL) protocol offered the limit of detection (LOD) as low as 0.061 nM and this result was very similar to that obtained by SPR, which was 0.051 nM. In the case of anti-hGH detection using pulsed amperometry (PA) with 3,3',5,5'-tetramethylbenzidine (TMB) and H(2)O(2) in the electrochemical system the LOD was the lowest - 0.027 nm. Lower reproducibility of the analytical signal and higher limit of detection was observed using cyclic voltammetry (CV) where LOD was 0.056 nM. PA detection shows 1.89, 2.07 and 2.26 times higher sensitivity if compared with SPR, CV and ECL, respectively. This work demonstrates successful simultaneous exploitation of several techniques to detect the specific anti-hGH antibodies using indirect immunoassay format on the same area of the SPR-chip.  相似文献   

17.
In the current paper, we report the development of a new capillary electrophoresis method using pre-column derivatization and laser-induced fluorescence detection for the determination of ephedrine and amphetamine drugs. Our new method allows for the identification and quantification of six commonly used illicit drugs namely pseudoephedrine, ephedrine, amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, and 3,4-methylenedioxymethylamphetamine, respectively, as well as propafenone (internal standard). Following derivatization with fluorescein isothiocyanate, a total of six amphetamine drugs and the internal standard could readily be separated using a fused-silica 75 micromID x 60 cm length (effective length: 50.2 cm) capillary column. The mobile phase consisted of buffer containing 20mM borate (pH 12, adjusted with sodium hydroxide). Samples were injected in pressure mode with the capillary being operated at 25kV/25 degrees C, and the detection of the derivatized compounds was sought using a laser-induced fluorescence (LIF) detector (lambda(ex)=488 nm and lambda(em)=520 nm), with a run-time of 20 min. The current method was validated with regard to precision (relative standard deviation, RSD), accuracy, sensitivity, linear range, limit of detection (LOD) and limit of quantification (LOQ). In human blood and urine samples, detection limits were 0.2 ngmL(-1), and the linear range of the calibration curves was 0.5-100 ngmL(-1). The intra-day and inter-day precisions were both less than 13.22%.  相似文献   

18.
A new liquid chromatography assay with isocratic elution and tandem mass spectrometry detection (LC-MS/MS) using an electrospray ionization interface in the multiple reaction monitoring mode was developed and validated for ertapenem determination in microdialysate samples. Linearity was demonstrated between 10ngmL(-1) (lower limit of quantification, LLoQ) and 160ngmL(-1). The precision (CV%) and accuracy (bias%) in microdialysates at the LLoQ were respectively 2.2% and 17.3% within-day and 10.6% and 2.7% between-days. Ertapenem was stable for 1 month at -20 degrees C and -80 degrees C but unstable at +4 degrees C. This new LC-MS/MS assay is simple, rapid and more sensitive than previously described assays.  相似文献   

19.
We demonstrate a highly sensitive electrochemical immunosensor based on the combined use of substrate recycling and carbon nanotubes (CNTs) coated with tyrosinase (TYR) and magnetic nanoparticles (MNP). Both TYR and MNP were immobilized on the surface of CNTs by covalent attachment, followed by additional cross-linking via glutaraldehyde treatment to construct multi-layered cross-linked TYR-MNP aggregates (M-EC-CNT). Magnetically capturable, highly active and stable M-EC-CNT were further conjugated with primary antibody against a target analyte of hIgG, and used for a sandwich-type immunoassay with a secondary antibody conjugated with alkaline phosphatase (ALP). In the presence of a target analyte, a sensing assembly of M-EC-CNT and ALP-conjugated antibody was attracted onto a gold electrode using a magnet. On an electrode, ALP-catalyzed hydrolysis of phenyl phosphate generated phenol, and successive TYR-catalyzed oxidation of phenol produced electrochemically measurable o-quinone that was converted to catechol in a scheme of substrate recycling. Combination of highly active M-EC-CNT and substrate recycling for the detection of hIgG resulted in a sensitivity of 27.6 nA ng(-1) mL(-1) and a detection limit of 0.19 ng mL(-1) (1.2 pM), respectively, representing better performance than any other electrochemical immunosensors relying on the substrate recycling with the TYR-ALP combination. The present immunosensing system also displayed a long-term stability by showing a negligible loss of electrochemical detection signal even after reagents were stored in an aqueous buffer at 4°C for more than 6 months.  相似文献   

20.
In this article, a conspicuously simple and highly sensitive amperometric immunosensor based on the sequential electrodeposition of Prussian blue (PB) and gold nanoparticles (GNPs) on multiwalled carbon nanotube (MWCNT)-modified glassy carbon electrode (GCE) surface is proposed for the detection of α-fetoprotein (AFP). By comparison with PB, the MWCNT/PB composite film had been proven to show much better electrochemical stability and a larger response current. The electrodeposited GNP film can be used not only to immobilize biomolecules but also to avoid the leakage of PB and to prevent shedding of MWCNT/PB composite film from the electrode surface. The performance and factors influencing the performance of the immunosensor were investigated. Under optimal experimental conditions, the proposed immunosensor for AFP was observed with an ultralow limit of detection (LOD) equal to 3 pg/ml (at 3δ), and the linear working range spanned the concentrations of AFP from 0.01 to 300 ng/ml. Moreover, the immunosensor, as well as a commercially available kit, was examined for use in the determination of AFP in real human serum specimens. More significant, the assay mentioned here is simpler than the traditional enzyme-linked immunosorbent assay (ELISA), and an excellent correlation of levels of AFP measured was obtained, indicating that the developed immunoassay could be a promising alternative approach for detection of AFP and other tumor markers in the clinical diagnosis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号