首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
A column-switching high-performance liquid chromatography method with ultraviolet detection at 210 nm has been developed for the determination of N-(trans-4-isopropylcyclohexylcarbonyl)-d-phenylalanine (AY4166, I) in human plasma. Plasma samples were prepared by solid-phase extraction with Sep-Pak Light tC18, followed by HPLC. The calibration graph for I was linear in the range 0.1–20 μg/ml. The limit of quantitation of I, in plasma, was 0.05 μg/ml. The recovery of spiked I (0.5 μg/ml) to drug-free plasma was over 92% and the relative standard deviation of spiked I (0.5 μg/ml) compared to drug-free plasma was 4.3% (n = 8).  相似文献   

2.
A method for the analysis of the AMPA (α-amino-3-hydroxy-5-methyl-4-isoxazolepropionate) receptor antagonist LY300164 (compound I) and its N-acetyl metabolite (compound II) in plasma was developed. The assay utilized solid-phase extraction on a C18 Bond Elut cartridge followed by reversed-phase HPLC with UV detection at 310 nm. The method exhibited a large linear range from 0.05 μg/ml to 50 μg/ml with an intra-sassay accuracy for compound I and compound II ranging from 89.0% to 114.5% and intra-assay precision ranging from 0.5 to 15.3% in mouse, rat, dog, and monkey plasma. The inter-assay accuracy of compound I and compound II was 93.3% to 101.8% and the inter-assay precision was 1.6% to 11.2% in dog plasma. The lower limit of quantitation was 0.05 μg/ml for compound I in plasma from all species tested. The lower limit of quantitation for compound II was 0.05 μg/ml in dog and monkey plasma and 0.1 μg/ml in mouse and rat plasma. Extracts of compound I and II from dog plasma were shown to be stable for 24 h at room temperature, and both compounds were stable when spiked into rat and monkey plasma frozen at −70°C for 27 days. The method has shown to be useful in the investigation of the pharmacokinetics of the parent compound (I) and metabolite (II) in preclinical studies.  相似文献   

3.
A method is reported for the measurement of quercetin in human plasma using reversed-phase high-performance liquid chromatography (HPLC). Quercetin and kaempferol (as internal standard) were spiked into plasma samples and extracted using C18 Sep-Pak Light cartridges (efficiency > 85%). Flavonoids were eluted with aqueous acetone (50% v/v, pH 3.5), dried down and redissolved in aqueous acetone (45% v/v, pH 3.5). The increased osmolarity promoted a phase separation and the water-saturated acetone layer, containing the flavonoids, was analysed by HPLC with aqueous acetone mobile phase (45% v/v acetone in 250 mM sodium dihydrogen sulphate. The mixture was adjusted to pH 3.5 with phosphoric acid and used at a flow-rate of 1.0 ml/min) and μBondapak C18 column (150 × 3.9 mm I.D., 10 μm particle size). The detection limit (A375 nm) for quercetin in plasma was 0.1 μg/ml (300 nM). The method also detects metabolites of quercetin, although these are not yet identified.  相似文献   

4.
Determinative and confirmatory methods of analysis for pirlimycin (I) residue in bovine milk and liver have been developed based on HPLC-thermospray (TSP) MS. Milk sample preparation consisted of precipitating the milk proteins with acidified acetonitrile followed by a solvent partitioning with a mixture of n-butyl chloride and hexane, extraction of I from the aqueous phase into methylene chloride (MC), and solid-phase extraction clean-up. For liver, samples (2 g) were extracted with 0.25% trifluoroacetic acid in acetonitrile. The aqueous component was released from the organic solvent with n-butyl chloride. The aqueous solution was reduced in volume by evaporation, basified with ammonium hydroxide, then extracted with MC. The MC was evaporated to dryness and the dried residue reconstituted in 2.0 ml of 0.1 M ammonium acetate for analysis. A chromatographically resolved stereoisomer of I with TSP-MS response characteristics identical to I was used as an internal standard (I.S.) for quantitative analysis based on the ratio of peak areas of I to I.S. in the protonated molecular-ion chromatogram at m/z 411.2.The method for milk was validated by the analysis of control milk samples spiked with I at concentrations from 0.05 to 0.8 μg/ml. The overall recovery of pirlimycin across this concentration range was 95.4% ± 8.7%. The limit of quantitation (LOQ) and limit of confirmation (LOC) of the method were validated to be 0.05 μg/ml and 0.10 μg/ml, respectively.The method for liver was validated by the analysis of control liver samples spiked with I at concentrations ranging from 0.025 to 1.0 μg/g. The overall recovery of pirlimycin was 97.6% ± 5.1% in this concentration range. The validated limit of quantitation (LOQ) and limit of confirmation (LOC) of the method were 0.025 μg/g and 0.10 μg/g, respectively.Four diagnostic ions for I were monitored for confirmation: the pseudo-molecular ions (M + H)+ at m/z 411.2 (35Cl) and m/z 413.2 (37Cl), and fragment ions at m/z 375.2 and 158.1. Confirmatory criteria were defined for these assays.  相似文献   

5.
An ultrafiltration-light absorption spectrometric method for soluble molybdate-reactive silicon was assessed and applied to bovine and ovine blood plasma and sera, giving precise analytical results. Interfering protein above molecular weight 10,000–25,000 was removed by ultrafiltration, and silicon in ultrafiltrates was quantitated by measuring light absorption at 810 nm of the 1,2,4-aminonaphthol sulfonic acid/ascorbic acid-reduced silicomolybdate. Chemical interferences on the color-forming reaction of remaining blood components were tested by measuring recoveries of silicon added to real blood plasma samples and to synthetic blood plasma solutions, the latter containing typical levels of the major ions Na+, K+, Ca2+, HCO3?, and Cl?, together with varying quantities of the potential interferants (amount per analytical reaction): phosphate (0–0.5 mg P), ferric ion (0–3 mg), fluoride (0–1.25 mg), vanadate (0–0.5 mg V), arsenate (0–10 μg As), and germanate (0–0.5 μg Ge). The mean recovery of added 0.8–9 μg silicon/g of bovine and ovine plasma was 97.7% (SE = 1.0, n = 17); the mean recovery of 1 and 5 μg silicon from synthetic blood plasma solutions with interferant levels up to 50-fold that in normal plasma was 99.2% (SE = 0.3, n = 47). Silicon concentrations found in bovine and ovine blood plasma and sera were typically around 7 μg/ml with procedural reagent blanks consistently low at a mean of 0.12 μg/test (SD = 0.011, n = 20). The silicon level in Center for Disease Control bovine serum (reference specimen Lot R-2274) was found to be (mean ± SE, n = 10) 1.147 ± 0.013 μg/g or 1.172 ± 0.013 μg/ml (25°C). The method detectivity (detection limit) was estimated at 0.03 μg.  相似文献   

6.
A simple and sensitive high-performance liquid chromatograhic (HPLC) method for the determination of (+)-(S)-sotalol and (−)-(R)-sotalol in biological fluids was established. Following extraction with isopropyl alcohol from biological samples on a Sep-Pak C18 cartridge, the eluent was derivatized with 2,3,4,6-tetra-O-acetyl-β-d-glucopyranosol isothiocyanate (GITC). The diastereoisomeric derivatives are resolved by HPLC with UV detection at 225 nm. Calibration was linear from 0.022 to 4.41 μg/ml in human plasma and from 0.22 to 88.2 μg/ml in human urine for both (+)-(S)- and (−)-(R)-sotalol. The lower limit of determination was 0.022 μg/ml for plasma and 0.22 μg/ml for urine. The within-day and day-to-day coefficients of variation were less than 7.5% for each enantiomer at 0.09 and 1.8 μg/ml in plasma and at 0.44 and 4.4 μg/ml in urine. The method is also applicable to other biological specimens such as rat, mouse and rabbit plasma.  相似文献   

7.
A radioimmunoassay that measures Leb-active glycolipids in human plasma has been developed using antiserum from a goat immunized with a Leb blood group hapten, lacto-N-difucohexaose I, conjugated to polylysine. Binding by the antiserum of lacto-N-difucohexaose I conjugated to 125I-labeled bovine serum albumin is specifically inhibited by Leb-active ceramide hexasaccharide. Plasma levels of the glycolipid are quantitated by comparing the inhibitory activity of plasma with that of the purified Leb-active glycolipid. Plasma samples from 35 blood group O Le(a ? b +) individuals contain Leb-active ceramide hexasaccharide at an average concentration of 0.9 μg/ml (range: 0.2 to 2.5 μg/ml); no Leb-active glycolipid (less than 0.02 μg/ml) could be detected in plasma from blood group O Le(a + b?) or O Le(a? b?) individuals. Plasma from A1 Le(a ? b+) individuals contains less Leb-active glycolipid than plasma from A2 Le(a? b+) individuals: its level in 19 samples of A, Le(a? b+) plasma averages 0.2 μg/ml (range: 0.1 to 0.45 μg/ml), and its level in 9 samples of A2 Le(a? b+) plasma averages 1.1 μg/ml (range 0.8 to 1.3 μg/ml). About one-third of the total Leb-active glycolipid in whole blood is associated with erythrocytes and the rest is found in plasma.  相似文献   

8.
A rapid high-performance liquid chromatography assay has been developed for the drug atovaquone, which is currently being used to treat Pneumocystis carinii pneumonia and Taxoplasma gondii encephalitis associated with the acquired immunodeficiency syndrome (AIDS). Protein is precipitated from plasma with acetonitrile-aqueous 1% acetic acid (85:15). The supernatant is assayed on a C6 column using methanol-10 mM triethylamine in aqueous 0.2% trifluoroacetic acid (76:24) with detection at 254 nm. The working assay range was 0.5 to 50 μg/ml. Recovery was 97% and the between-day coefficients of variation were 2.1% at 50 μg/ml and 10.3% at 1 μg/ml. A number of drugs commonly used to treat AIDS and its complications did not interfere with the assay.  相似文献   

9.
A differential pulse polarographic assay for plasma vitamin K3 (menadione) has been developed. Details of the assay are (i) lipid-soluble material is extracted from plasma into ether by the method of Bjornsson et al. [(1978) Thromb. Haemostas.2, 466–473]; (ii) ether is evaporated under nitrogen and the residue is dissolved in the supporting electrolyte, methanol: 0.2 m borate buffer (9:1), pH 6.8; (iii) current height is measured at ?0.32 V vs SCE on the differential pulse polarogram. The lower sensitivity limit of this technique after addition of standard vitamin K3 to plasma is 0.3 μm; the calibration curve is linear from 0.6 through 10 μm. Two patients treated with a single dose of menadiol sodium diphosphate, 20 mg/M2 i.m., achieved measurable plasma vitamin K3 levels at 0.5 to 1.0 h ranging between 0.5 (0.08 μg/ml) and 2 μm (0.3 μg/ml).  相似文献   

10.
Lamotrigine (lamictal) is a new anticonvulsant drug recently approved by the FDA for clinical use. Therapeutic monitoring of lamotrigine is useful for patient management (therapeutic range 1–4 μg/ml). Here we describe a gas chromatography–mass spectrometric identification and quantitation of lamotrigine after extraction from human serum and derivatization. Lamotrigine was extracted from alkaline serum with chloroform and derivatized with N-methyl-N-(tert.- butyldimethysilyl) trifluoroacetamide containing 2% tert.-butyldimethylchlorosilane. Oxazepam-d5 was used as an internal standard. The tert.-butyldimethylsilyl derivative of lamotrigine showed distinct molecular ions at m/z 483 and 485 as well as other peaks at m/z 426, 370 and 334 for unambiguous identification. The base peak was observed at m/z 199. Similarly, the tert.-butyldimethysilyl derivative of oxazepam-d5 showed molecular ions at m/z 519 and 521 along with other characteristic peaks at m/z 462, 376 and 318. For the analysis of lamotrigine, the mass spectrometer was operated in the selective ion monitoring mode. The within-run and between-run precisions were 4.3% (mean=3.01, S.D.=0.13 μg/ml) and 5.1% (mean=2.93, S.D.=0.15 μg/ml), respectively at a serum lamotrigine concentration of 3.0 μg/ml. The within-run and between-run precisions were 8.2% (mean=0.49, S.D.=0.04 μg/ml) and 10.6% (mean=0.47, S.D.=0.05 μg/ml), respectively at a serum lamotrigine concentration of 0.5 μg/ml. The assay was linear for serum lamotrigine concentrations of 0.5–20 μg/ml. The detection limit was 0.25 μg/ml. The assay was free from interferences from common tricyclic antidepressants, benzodiazepines, other common anticonvulsants, salicylate and acetaminophen.  相似文献   

11.
We have developed and validated a sensitive and selective assay for the quantification of paclitaxel and its metabolites 6α,3′-p-dihydroxypaclitaxel, 3′-p-hydroxypaclitaxel and 6α-hydroxypaclitaxel in plasma, tissue, urine and faeces specimens of mice. Tissue and faeces were homogenized (approximately 0.1–0.2 g/ml) in bovine serum albumin (40 g/I) in water, and urine was diluted (1:5, v/v) in blank human plasma. Sample pretreatment involved liquid-liquid extraction of 200–1000 μl of sample with diethyl ether followed by automated solid-phase extraction using cyano Bond Elut column. 2′-Methylpaclitaxel was used as internal standard. The overall recovery of the sample pretreatment procedure ranged from 76 ot 85%. In plasma, the lower limit of detection (LOD) and the lower limit of quantitation (LLQ) are 15 and 25 ng/ml, respectively, using 200 μl of sample. In tissues, faeces and urine the LLQs are 25–100 ng/g, 125 ng/g and 25 ng/ml, respectively, using 1000 μl (faeces: 200 μl) of homogenized or diluted sample. The concentrations in the various biological matrices, for validation procedures spiked with known amounts of the test compounds, are read from calibration curves constructed in blank human plasma in the range 25–100 000 ng/ml for paclitaxel and 25–500 ng/ml for the metabolites. The accuracy and precision of the assay fall within the generally accepted criteria for bio-analytical assays.  相似文献   

12.
A liquid chromatographic procedure using UV detection was coupled with ultrafiltration for the quantitation of free phenylbutazone in bovine plasma, in the range of 20 ng/ml to 2.0 μg/ml. Whole plasma samples (0.5 to 1 ml) were placed in a 2-ml centrifugal concentrator with a molecular-mass cut-off membrane of 10 000 and centrifuged at 4500 g for 2 h at 4°C using a fixed angle rotor. The ultrafiltrate was transferred to an LC vial with a 200-μl insert and 100 μl was injected into an LC system. The chromatographic system used a C18 reversed-phase column connected to a UV detector set at 264 nm. The mobile phase was 0.2 M sodium phosphate buffer (pH 7)–methanol (1:1). Recoveries of phenylbutazone from protein-free plasma water fortified at levels of 20 ng/ml to 2 μg/ml ranged from 91 to 93%, with relative standard deviations (R.S.D.s) ranging from 1 to 4%. The concentration of incurred non-protein bound phenylbutazone obtained from a cow intravenously dosed twice with 2 g phenylbutazone, 8 h apart, was 111, 26 and 11 ng/ml for 2, 72 and 104 h post first phenylbutazone dose, respectively.  相似文献   

13.
The effects of isoprenaline and the selective β2-receptor terbutaline were investigated on strips from human myometrium obtained at caesarean sections. In normally polarized preparations both amines (isoprenaline 0.02 – 0.4 μg/ml, terbutaline 0.2 – 8 μg/ml) decreased the frequency and the amplitude of the spontaneous contractile activity. This action was not affected by phenoxybenzamine, 0.5 μg/ml, but could be blocked by propranolol, 0.1 μg/ml. In myometrial strips, depolarized by increasing the extracellular potassium concentration, isoprenaline, 0.004 – 0.4 μg/ml, and terbutaline, 0.008 – 8 μg/ml, had relaxing effects that were unaffected by phenoxybenzamine, 0.5 μg/ml, but could be blocked by propranolol, 0.1 gm/ml. It is concluded that the effects of the tested amines are mediated by actions on β-adrenoceptors, probably β2-receptors.  相似文献   

14.
A flame atomic emission spectrometric method, is described for the determination of aluminium in bovine blood plasma matrices. Plasma samples are wet-digested and solutions are aspirated into a conventional nitrous oxide-acetylene flame. Analyte emission is monitored at 396.15 nm with corrections for background emission being obtained from measurements several tenths nm on both sides of the aluminium line. The mean recovery of 0.3–5 μg/ml aluminium added to model solutions containing 500–5000 μg Na/ml, 50–1000 μg Ca/ml, 2000–5000 μg K/ml, or simulated plasma digests containing Na, K, and Ca was 100,6% (SD = 10.9, df = 60); the mean recovery of 0.3, 0.5, and 1.0 μg/ml aluminium added to blood plasma before digestion was 94.3% (SD = 9.8, df = 33) indicating no serious interferences. For standard solutions, the detection limit (signal: peak-to-peak noise = 1) was 0.02 μg/ml by flame emission, and 0.12 μg/ml by atomic absorption measurements with the same instrument. A sample taken through the analytical procedure, gave a detection limit of 0.05 μg/ml suggesting the submicrogram per milliliter region as the lower practical limit of the method.  相似文献   

15.
A high-performance liquid chromatographic method for quantitation of ibuprofen from serum and application of this method to ibuprofen disposition in the dog is described. The drug was extracted from acidified plasma with dichloromethane. The internal standard used was a methanolic solution of 4-n-butylphenylacetic acid. A μBondapak C1 column was used for analysis; the mobile phase was methanol—water—glacial acetic acid (pH 3.4) (75:24:1, v/v). A wavelength of 272 nm was used to monitor ibuprofen and the internal standard.Method sensitivity was 0.5 μg/ml serum using either 0.5 or 1.0 ml of sample, and no interference was found from endogenous compounds or other commonly used anti-inflammatory agents. The coefficients of variation of the method were 4.2% and 6.0% for samples containing 50.0 and 6.25 μg/ml of ibuprofen, respectively, and the calibration curve was linear for the range of 0.5 to 100 μg/ml. This method was demonstrated to be suitable for pharmacokinetic and/or biopharmaceutical studies of ibuprofen in man and the dog.  相似文献   

16.
The purpose of this investigation was to determine the influence of cholecystokinin octapeptide (CCK-OP) on pituitary-adrenal hormone secretion. CCK-OP at a dose of 5 μg/kg (i.p.) elevated plasma corticosterone from 27 to 43 μg/100 ml in one experiment and from 12 to 50 μg/100 ml in a second experiment: Lower doses of CCK-OP (0.5 μg/kg) elevated corticosterone from 12 μg/100 ml to 20 μg/100 ml. CCK-OP (1, 10, and 100 ng/ml) had no effect on ACTH-induced corticosterone released by isolated adrenal cells in vitro when tested in the presence of 50 pg of ACTH1?24. 100 and 500 ng of CCK-OP resulted in an increased pituitary ACTH release equal to 123% (n.s.) and a 206% (P < 0.05) of control, respectively. In comparison, a 35 hypothalamic stalk median eminence equivalent increased ACTH release to 313% of control (P < 0.05). The exact mechanism of this CCK effect on pituitary ACTH release is unknown. Although it is likely that the direct effects on the pituitary in vitro represent a pharmacologic and not a physiologic effect of this peptide, in vivo doses are between doses used for pancreatic effects and satiety effects suggesting that there may be a physiologic stimulating action of this peptide on the hypothalamic-pituitary-adrenal axis but at a level above the adrenal and pituitary.  相似文献   

17.
Two different enantioselective chiral chromatographic methods were developed and validated to investigate the disposition of the β1-receptor antagonist atenolol in blood and in brain extracellular fluid of rats (tissue dialysates). System A for the plasma samples was a one-column chromatographic system with a Chiral CBH column with an aqueous buffer as mobile phase into which cellobiose was added for selective regulation of the retention of the internal standard, (S)-metoprolol. The plasma samples were analysed after a simple extraction procedure. The limit of quantitation was 0.2 μg/ml for the atenolol enantiomers. The repeatability of the medium concentration quality control plasma sample (6.0 μg rac-atenolol/ml) was 11–18% for the enantiomers. The dynamic linear range of the plasma samples was 0.5–20 μg/ml. For system B, since atenolol is an extremely hydrophilic drug, the tissue dialysate sample required a much more sensitive system as compared to the plasma samples. A coupled column system was used for peak compression of the enantiomers in the eluate after the separation on the Chiral CBH column, hence increasing the detection sensitivity. The limit of quantification was 0.045 μg/ml for the atenolol enantiomers in artificial CSF. The repeatability of the medium concentration quality control samples (0.1 and 4.0 μg rac-atenolol/ml in artificial CSF and Hepes Ringer, respectively) was 2.8–9.3% for the two enantiomers. The dynamic linear range of the brain samples was 0.05–1.0 and 0.5–20 μg/ml in artificial CSF and Hepes Ringer, respectively. Chirality 9:329–334, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

18.
A simple, specific and sensitive high-performance liquid chromatographic method has been developed for the simultaneous determination of rufloxacin, fenbufen and felbinac in human plasma. Plasma, spiked with internal standard, was vortex-mixed for 1 min with a mixture of dichloromethane-diethyl ether (80:20, v/v). The evaporated extract was dissolved in 0.02 M NaOH. Drugs were resolved at room temperature on a 5 μm Zorbax SAX column (250×4.6 min I.D.) equipped with a 20×4.6 mm anion-exchange Vydac AXGU ( 10 μm particle size) precolumn. The mobile phase consisted of acetonitrile and phosphate buffer (pH 7.0), delivered at a flow-rate of 1.2 ml/min. Detection was made at 280 nm, 2-[4-(2′-Furoyl)phenyl]propionic acid was used as internal standard. The calibration curve was linear from 0.2 to 10μg/ml for rufloxacin, from 0.5 to 30 μg/ml for fenbufen and from 0.2 to 10 μg/ml for felbinac, respectively. The detection limit was 0.1 μg/ml for rufloxacin. 0.3 μg/ml for fenbufen and 0.1 μg/ml for felbinac, respectively.  相似文献   

19.
A new high-performance liquid chromatographic method for simultaneous determination of primidone (PRM) and of its three major metabolites, phenobarbital (PB), p-hydroxyphenobarbital (p-HO-PB) and phenylethylmalonamide (PEMA), in rat urine, was developed. After acid hydrolysis, these compounds were extracted from urine by means of a Bond Elut Certify LRC column with good clean-up. The extracts were chromatographed on a C18 reversed-phase column using isocratic elution at 40°C, with UV detection at 227 nm. The limit of detection was 0.5 mg/ml for the four compounds. Good linearity (r2>0.99) was observed within the calibration ranges studied: 37.4–299.3 μg/ml for PRM, 26.4–211.2 μg/ml for PB, 12.5–100.2 μg/ml for p-HO-PB and 12.1–97.0 μg/ml for PEMA. Repeatability was in the range 3.1–6.8%. This method constitutes a useful tool for studies on the influence of various parameters on primidone metabolism.  相似文献   

20.
Heparin inhibited the adenylate cyclase activity of semipurified rat pancreatic plasma membranes stimulated by hormones and by Gpp(NH)p but not by fluoride or when in the persistently active state. When observed, the inhibition was rapid and sustained. It was of a noncompetitive type and never exceeded 20% for secretin. The inhibition of Gpp(NH)p-stimulated activity was more pronounced (48% inhibition at a heparin concentration of 50 μg/ml). For the C-terminal octapeptide of pancreozymin (CCK-8)-stimulated adenylate cyclase, the inhibition amounted to 93% at 50 μg/ml. This inhibition was competitive at low heparin concentration and of a mixed type above 10 μg/ml. Besides, heparin inhibited (I50 = 6 μg/ml) the binding of peptides of the CCK family to their specific receptors without affecting the apparent Kd value of binding. Taken together, these relatively specific effects of heparin gave evidence in favor of the existence of CCK spare receptors. Dextran sulfate was more potent than heparin as an inhibitor of adenylate cyclase activation while chondroitin-4-sulfate and chondroitin-6-sulfate were ineffective. Dansylated pancreatic plasma membranes exhibited characteristics of adenylate cyclase activation by CCK-8 which were similar to those found for untreated membranes exposed to heparin.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号