首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We established a high-performance liquid chromatographic method for separating and quantifying carbamylated dehydroascorbate derivative (CDA), a reaction product of cyanate with dehydroascorbate. The separation of CDA from interfering substances was achieved by anion-exchange HPLC using a TSK gel SAX (250×4.6 mm I.D.) column and 0.12 M NaCl eluent. The detection of CDA was achieved through two steps: (1) degradation of CDA to cyanate and amino compounds in alkaline solution, and (2) detection of these products by an indophenol reaction. For the processing of plasma and urine samples, anion-exchange solid-phase extraction was used. The detection limit for quantitative determination was 0.1 μM CDA (S/N=3). The linear range found applying the optimized conditions was 0.2 to 200 μM. The intra- and inter-day assay precision (R.S.D.) of CDA (10 μM) were 4.8 and 7.2% for rat plasma, and 4.0 and 4.9% for rat urine, respectively. The usefulness of the present method was proved by the application to plasma and urine samples. The study of the biokinetics of CDA in rats revealed that the elimination of CDA is due to urinary excretion.  相似文献   

2.
A new high-performance liquid chromatographic method with column switching has been developed for the simultaneous determination of metampicillin and its metabolite ampicillin in biological fluids. The plasma, urine and bile samples were injected onto a precolumn packed with LiChrosorb RP-8 (25–40 μm) after simple dilution with an internal standard solution in 0.05 M phosphate buffer (pH 7.0). The polar plasma components were washed out using 0.05 M phosphate buffer (pH 7.0). After valve switching, the concentrated drugs were eluted in the back-flush mode and separated by an Ultracarb 5 ODS-30 column with a gradient system of acetonitrile-0.02 M phosphate buffer (pH 7.0) as the mobile phase. The method showed excellent precision, accuracy and speed with a detection limit of 0.1 μg/ml. The total analysis time per sample was less than 40 min and the coefficients of variation for intra- and inter-assay were less than 5.1%. This method has been successfully applied to plasma, urine and bile samples from rats after intravenous injection of metampicillin.  相似文献   

3.
A reversed-phase, high-performance liquid chromatographic method employing fluorescence detection is described for the rapid quantification of plasma levels of quinidine, dihydroquinidine and 3-hydroxyquinidine. It involves protein precipitation with acetonitrile followed by direct injection of the supernatant into the chromatograph. For the preparation of plasma standards, pure 3-hydroxyquinidine was isolated from human urine by a simplified thin-layer chromatographic procedure. The mobile phase for the chromatography was a mixture of 1.5 mM aqueous phosphoric acid and acetonitrile (90:10) at a flow-rate of 2 ml/min. The intra-assay coefficient of variation for the assay of quinidine and 3-hydroxyquinidine over the concentration range 2.5–20 μmole/l was < 1% for both. Interassay coefficients of variation for quinidine (10 μmole/l) and 3-hydroxyquinidine (5 μmole/l) were 3.5% and 4.0% with detection limits of 50 and 25 μmole/l respectively. The method correlated well (r2 = 0.96) with an independently developed gas—liquid chromatographic—nitrogen detection assay for quinidine which also possessed a high degree of precision. (Intra-assay coefficient of variation 3.6% at 20 μmole/l). As expected, comparison of the high-performance liquid chromatographic assay with a published protein precipitation—fluorescence assay showed poor correlation (r2 = 0.78).  相似文献   

4.
The determination of quinine, (3S)-3-hydroxyquinine, 2′-quininone and (10R)- and (10S)-10,11-dihydroxydihydroquinine in plasma and urine samples is described. This is the first time the R and S configurations have been correctly assigned to the two metabolites of 10,11-dihydroxyquinine. One hundred microliter-plasma samples were protein precipitated with 200 μl cold methanol. Urine samples were 10–100× diluted and then directly injected into the HPLC. A reversed-phase liquid chromatography system with fluorescence detection and a Zorbax Eclipse XDB phenyl column and gradient elution was used. The within and between assay coefficients of variation of the method for quinine and its metabolites in plasma and urine was less than 13%. The lower limit of quantitation was in the range of 0.024–0.081 μM.  相似文献   

5.
This paper describes a high-performance liquid chromatographic method with fluorescence detection for the analysis of methyl-β-cyclodextrin (MEBCD) in plasma and cell lysate, after in situ complexation with 1-naphthol. The size-exclusion HPLC column packed with TSK 3000 SW gel, was equilibrated with an eluent mixture composed of methanol and purified water (2:98, v/v) containing 10−4 M 1-naphthol as a fluorophore. The detection is based on fluorescence enhancement caused by the formation of inclusion complexes and was performed at 290 and 360 nm for excitation and emission, respectively. The method involved a simple treatment of the samples with chloroform. Daunorubicin was used as internal standard. Limits of quantitation were 0.8 μM in plasma and 0.5 μM in cell lysate. Detection limits of 0.5 μM (50 pmol) and 0.3 μM (30 pmol) were obtained for MEBCD in the two media, respectively. Linear detection response was obtained for concentrations ranging from 1 to 100 μM in plasma and cell lysate. Recovery from plasma proved to be more than 40%. Precision, expressed as C.V. was in the range of 4 to 11%. Accuracy ranged from 89 to 105%.  相似文献   

6.
A high-performance liquid chromatogaphic method was developed for determining the concentrations of ticarcillin (TIPC) epimers in human plasma and urine. Samples were prepared for HPLC analysis with a solid-phase extraction method and the concentrations of TIPC epimers were determined using reversed-phase HPLC. The mobile phase was a mixture of 0.005 M phosphate buffer (pH 7.0) and methanol (12:1, v/v) with a flow-rate of 1.0 ml/min. TIPC epimers were detected at 254 nm. Baseline separation of the two epimers was observed for both plasma and urine samples with a detection limit of ca. 1 μg/ml with a S/N ratio of 3. No peaks interfering with either of the TIPC epimers were observed on the HPLC chromatograms for blank plasma and urine. The recovery was more than 80% for both plasma and urine samples. C.V. values for intra- and inter-day variabilities were 0.9–2.1 and 1.1–6.4%, respectively, at concentrations ranging between 5 and 200 μg/ml. The present method was used to determine the concentrations of TIPC epimers in plasma and urine following intravenous injection of TIPC to a human volunteer. It was found that both epimers were actively secreted into urine and that the secretion of TIPC was not stereoselective. Plasma protein binding was also measured, which revealed stereoselective binding of TIPC in human plasma.  相似文献   

7.
A method for the simultaneous direct determination of salicylate (SA), its labile, reactive metabolite, salicyl acyl glucuronide (SAG), and two other major metabolites, salicyluric acid and gentisic acid in plasma and urine is described. Isocratic reversed-phase high performance liquid chromatography (HPLC) employed a 15-cm C18 column using methanol-acetonitrile-25 mM acetic acid as the mobile phase, resulting in HPLC analysis time of less than 20 min. Ultraviolet detection at 310 nm permitted analysis of SAG in plasma, but did not provide sensitivity for measurement of salicyl phenol glucuronide. Plasma or urine samples are stabilized immediately upon collection by adjustment of pH to 3–4 to prevent degradation of the labile acyl glucuronide metabolite. Plasma is then deproteinated with acetonitrile, dried and reconstituted for injection, whereas urine samples are simply diluted prior to injection on HPLC. m-Hydroxybenzoic acid served as the internal standard. Recoveries from plasma were greater than 85% for all four compounds over a range of 0.2–20 μg/ml and linearity was observed from 0.1–200 μg/ml and 5–2000 μg/ml for SA in plasma and urine, respectively. The method was validated to 0.2 μg/ml, thus allowing accurate measurement of SA, and three major metabolites in plasma and urine of subjects and small animals administered salicylates. The method is unique by allowing quantitation of reactive SAG in plasma at levels well below 1% that of the parent compound, SA, as is observed in patients administered salicylates.  相似文献   

8.
DZ-2640 is a new oral carbapenem antibiotic having a dihydro-pyrroloimidazole ring as a side chain and a pivaloyloxymethyl (POM) ester prodrug of DU-6681, the active parent compound. A simple and sensitive column-switching semi-microcolumn high-performance liquid chromatographic method for the determination of DU-6681 in human plasma and urine has been developed. Human plasma was diluted with an equal volume of 1 M MOPS buffer (pH 7.0) and the mixture was filtered through an Ultrafree C3GV. The resulting filtrate was injected without further cleanup onto the HPLC system. Human urine was diluted with an equal volume of 1 M MOPS buffer (pH 7.0) and the mixture was directly injected onto the HPLC system. The analyte was detected by monitoring the column effluent with UV light at a wavelength of 300 nm, which resulted in the limit of quantitation of 0.008 μg/ml of plasma and 0.32 μg/ml of urine. Calibration curves were linear in the range of 0.008 to 5.85 μg/ml in plasma and 0.32 to 104.4 μg/ml in urine. The present methods showed greatly increased sensitivity for DU-6681 compared to conventional HPLC methods and also showed satisfactory recovery, selectivity, precision, and accuracy. Stability studies showed that 1 M MOPS buffer (pH 7.0) acted as a stabilizer. In plasma and urine diluted with equal volume of the buffer, DU-6681 showed good stability at −80°C for up to 4 weeks with no significant loss of the drug.  相似文献   

9.
Nitro- -arginine ( -NNA) is an inhibitor of the enzyme nitric oxide synthase (NOS). We developed a simple, sensitive and reproducible reversed-phase high-performance liquid chromatographic method for detection of nitro-arginine ( - and -enantiomer) in rat plasma and urine. Samples were treated with perchloric acid, neutralized and eluted through a C8 reversed-phase column with a mobile phase of 18.5 mM heptanesulfonic acid-10% methanok in water using theophylline as an internal standard. Plasma recovery for both isomers was complete, and the sensitivity limit was 0.5 μg/ml. This method may be used for disposition studies of -NNA in small animals.  相似文献   

10.
A simple and rapid (extractionless) high-performance liquid chromatographic method with UV detection, at 330 nm, was developed for the simultaneous determination of piroxicam and its major metabolite, 5′-hydroxypiroxicam, in human plasma and urine. Acidified plasma and alkali-treated urine samples are used and naproxen is added as internal standard. The separation is performed at 40°C on a C18 Spherisorb column with acetonitrile-0.1 M sodium acetate (33:67, v/v, pH 3.3) as mobile phase. The retention time is 2.2 min for 5′-hydroxypiroxicam, 2.6 min for piroxicam and 3.2 min for naproxen. The detection limit is 0.05 μg/ml using a 100-μl loop.  相似文献   

11.
High-performance liquid chromatography with both absorbance and fluorescence detection has been applied to the determination of the potential anti-tumour agent combretastatin A-4 and its phosphate ester in murine and human plasma. The presence of different interfering peaks in the two species makes absorbance detection at 295 nm the method of choice for the mouse, and fluorescence detection (295 nm/390 nm) for human plasma. The calibration was linear over the range studied (0.01–50 μM for combretastatin A-4, 0.02–200 μM for combretastatin A-4 phosphate), with quantitation limits of 0.05 μM for both drugs in the mouse, and 0.05 μM and 0.0125 μM for the phosphate ester and free drug, respectively, in human plasma. The method should be useful for pharmacokinetic studies in the forthcoming Phase I clinical trial of combretastatin A-4 phosphate.  相似文献   

12.
A simple and sensitive high-performance liquid chromatograhic (HPLC) method for the determination of (+)-(S)-sotalol and (−)-(R)-sotalol in biological fluids was established. Following extraction with isopropyl alcohol from biological samples on a Sep-Pak C18 cartridge, the eluent was derivatized with 2,3,4,6-tetra-O-acetyl-β-d-glucopyranosol isothiocyanate (GITC). The diastereoisomeric derivatives are resolved by HPLC with UV detection at 225 nm. Calibration was linear from 0.022 to 4.41 μg/ml in human plasma and from 0.22 to 88.2 μg/ml in human urine for both (+)-(S)- and (−)-(R)-sotalol. The lower limit of determination was 0.022 μg/ml for plasma and 0.22 μg/ml for urine. The within-day and day-to-day coefficients of variation were less than 7.5% for each enantiomer at 0.09 and 1.8 μg/ml in plasma and at 0.44 and 4.4 μg/ml in urine. The method is also applicable to other biological specimens such as rat, mouse and rabbit plasma.  相似文献   

13.
A direct high-performance liquid chromatographic (HPLC) assay was developed for the separation and determination of 4-methylumbelliferone (4MU) and its glucuronide (MUG) and sulfate (MUS) conjugates in the cell-free perfusate (“plasma”) from in situ perfused rat intestine—liver preparation. In addition, a procedure was developed to extract and determine 4MU in the whole blood perfusate. Perfusate plasma containing an internal standard (umbelliferone) was precipitated with methanol (1:4, v/v), and injected into a reversed-phase HPLC system with gradient elution. 4MU and the same internal standard were also extracted directly from the whole blood perfusate with ethyl acetate and injected into a reversed-phase HPLC system with isocratic elution. Inter- and intra-day precision studies (n = 5 for each) for both the plasma and whole blood procedures demonstrated relative standard deviations of less than 10% at all concentrations studied. The compounds were stable in either the plasma or blood extracts at room temperature for up to 72 h. The procedures were successfully used to analyze perfusate samples obtained from the single-pass in situ perfusion of rat intestine—liver system with either trace (0.95 nM) or 32.3 μM concentrations of 4MU. The intestine was responsible for the formation of most of the MUG formed by the intestine—liver preparation during steady-state perfusion with either input concentration of 4MU.  相似文献   

14.
A high-performance liquid chromatography method for the simultaneous determination of pipecolic acid (Pip) and lysine (Lys), a precursor of Pip, in the rumen liquor and plasma of ruminant animals was established. Samples of rumen liquor and plasma were deproteinized with 50% acetonitrile and derivatized with a fluorescent agent 9-fluorenylmethyloxy carbonyl chloride (Fmoc-Cl). Chromatographic separation was achieved on a TSK gel ODS-80TM column using a reversed-phase gradient elution system. For the gradient elution, two mobile phases, A and B, were needed, both commonly consisted of: 5 mM l-proline, 2.5 mM cupric sulfate and 6.5 mM ammonium acetate. Mobile phase B additionally contains 50% (v/v) acetonitrile. The pH of both mobile phases was adjusted to 7.0. Derivatized Pip and Lys were detected on a fluorescent detector at excitation and emission wavelengths of 260 and 313 nm, respectively. The calibration curves were linear within the range 0 to 1 mM (r>0.999). The average recoveries for Pip and Lys were 95.9±1.8 and 93.2±2.5% in rumen liquor and 98.3±1.4 and 97.5±1.3% in plasma, respectively. The limits of detection for Pip and Lys were 0.6 and 0.7 μM in rumen liquor and 0.01 and 0.05 μM in plasma. The assay has acceptable precision, relative standard deviation (RSD) for reproducibility (within-day and day-to-day variation) were less than 5.2% for aqueous (5.0 μM Pip and Lys), MB9 (5.0 μM Pip and Lys), plasma (7.1 μM Pip and 85.6 μM Lys) and rumen liquor (28.4 μM Pip and 10.2 μM Lys) samples. The levels of Pip and Lys in faunated goats, determined from three animals over a period of two days sampling, were found to be 36.8±18.1 and 14.6±2.8 μM in rumen liquor, and 7.3±2.5 and 137.3±38.0 μM in plasma at 1 h after feeding. This is the first report on the normal levels of Pip in the rumen liquor and plasma of faunated goat.  相似文献   

15.
A high-performance liquid chromatographic method was developed for the simultaneous determination of phenylbutazone and its metabolites, oxyphenbutazone and γ-hydroxyphenylbutazone, in plasma and urine. Samples were acidified with hydrochloric acid and extracted with benzene—cyclohexane (1:1, v/v). The extract was redissolved in methanol and chromatographed on a μBondapak C15 column using a mobile phase of methanol—0.01 M sodium acetate buffer (pH 4.0) in a linear gradient (50 to 100% methanol at 5%/min; flow-rate 2.0 ml/min) in a high-performance liquid chromatograph equipped with an ultra-violet absorbance detector (254 nm). The detection limit for phenylbutazone, oxyphenbutazone and for γ-hydroxyphenylbutazone was 0.05 μg/ml.A precise and sensitive assay for the determination of phenylbutazone and its metabolites was established.  相似文献   

16.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of amdinocillin (formerly mecillinam) in human plasma and urine. The assay is performed by direct injection of a plasma protein-free supernatant or a dilution of urine. A 10-μm μBondapak phenyl column with an eluting solvent of water—methanol—1 M phosphate buffer, pH 7 (70:30:0.5) was used, with UV detection of the effluent at 220 nm. Azidocillin potassium salt [potassium-6-(d-(-)-α-azidophenyacetamido)-penicillanate] was used as the internal standard and quantitation was based on peak height ratio of amdinocillin to that of the internal standard. The assay has a recovery of 74.4 ± 6.3% (S.D.) in the concentration ranges of 0.1–20 μg per 0.2 ml of plasma with a limit of detection equivalent to 0.5 μg/ml plasma. The urine assay was validated over a concentration range of 0.025–5 mg/ml of urine, and has a limit of detection of 0.025 mg/ml (25 μg/ml) using a 0.1-ml urine specimen per assay.The assay was applied to the determination of plasma and urine concentrations of amdinocillin following intravenous administration of a 10 mg/kg dose of amdinocillin to two human subjects. The HPLC and microbiological assays were shown to correlate well for these samples.  相似文献   

17.
A simple high-performance liquid chromatographic (HPLC) method was developed for the determination of losartan and its E-3174 metabolite in human plasma, urine and dialysate. For plasma, a gradient mobile phase consisting of 25 mM potassium phosphate and acetonitrile pH 2.2 was used with a phenyl analytical column and fluorescence detection. For urine and dialysate, an isocratic mobile phase consisting of 25 mM potassium phosphate and acetonitrile (60:40, v/v) pH 2.2 was used. The method demonstrated linearity from 10 to 1000 ng/ml with a detection limit of 1 ng/ml for losartan and E-3174 using 10 μl of prepared plasma, urine or dialysate. The method was utilized in a study evaluating the pharmacokinetic and pharmacodynamic effects of losartan in patients with kidney failure undergoing continuous ambulatory peritoneal dialysis (CAPD).  相似文献   

18.
A simple and sensitive method for the enantioselective high-performance liquid chromatographic determination of methadone and its main metabolite, EDDP, in human urine is described. (−)-(R)-Methadone, (+)-(S)-methadone, (+)-(R)-EDDP, (−)-(S)-EDDP and imipramine as an internal standard are detected by ultraviolet detection at 200 nm. The enantiomers of methadone and EDDP were extracted from human urine by a simple liquid–liquid extraction procedure. The extracted sample was reconstructed in mobile phase and the enantiomers of methadone and EDDP were quantitatively separated by HPLC on a short analytical LiChrospher RP8 column coupled in series with a chiral AGP column. Determination of all four enantiomers was possible in the range of 0.03 to 2.5 μM. The recoveries of methadone enantiomers and EDDP enantiomers added to human urine were about 90% and 80%, respectively. The method was applicable for determination of methadone enantiomers and the enantiomers of its main metabolite in urine samples from methadone maintenance patients and patients suffering from severe chronic pain.  相似文献   

19.
A simple, accurate and sensitive high-performance liquid chromatographic method with UV detection was carried out to measure simultaneously plasma and urine concentrations of both p-aminohippuric acid and inulin. Following a simplified acid hydrolysis of the sample, the separation was carried out in 4 min using a C18 reversed-phase column with a flow-rate of 1 ml/min, and monitoring the absorbance at 280 nm. Within the investigated concentration ranges of inulin (0.1–3.2 mg/ml) and p-aminohippuric acid (0.0097–0.3 mg/ml), good linearity (r>0.99) was obtained. Within-run RSD ranged from 2.9 to 6.1% and between-run RSD ranged from 6.4 to 10%. Analytical recoveries were 101–112%, with little differences between plasma and urine samples. The detection limit was 1 μg/ml for all the analytes studied. This method might be ideal for renal function studies where a rapid and reproducible assessment of both renal glomerular filtration rate and blood flow-rate is required.  相似文献   

20.
PurposeEvaluation of different planning methods of treatment plan preparation for volumetric modulated arc therapy during total marrow irradiation (VMAT-TMI).MethodThree different planning methods were evaluated to establish the most appropriate VMAT-TMI technique, based on organ at risk (OAR) dose reduction, conformity and plan simplicity. The methods were: (M1) the sub-plan method, (M2) use of eight arcs optimised simultaneously and (M3) M2 with monitor unit reduction. Friedman ANOVA comparison, with Nemenyi's procedures, was used in the statistical analysis of the results.ResultsThe dosimetric results obtained for the planning target volume and for most OARs do not differ statistically between methods. The M3 method was characterized by the lowest numbers of monitor units (3259 MU vs. 4450 MU for M1 and 4216 MU for M2) and, in general, the lowest complexity. The variability of the monitor units from control points was almost half for M3 than M1 and M2 (i.e. 0.33 MU vs. 0.61 MU for M1 and 0.58 for M2). Analysing the relationship between the dose distributions obtained for the plans and their complexity, the best result was observed for the M3 method.ConclusionThe use of eight simultaneously optimised arcs with MU reduction allows to obtain VMAT-TMI plans that are characterized by the lowest complexity, with dose distributions comparable to the plans generated by other methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号