首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A high-performance liquid chromatography (HPLC) method has been developed for the determination of morphine and its main metabolites, morphine-6-glucuronide (M-6-G) and morphine-3-glucuronide (M-3-G), in plasma or cerebrospinal fluid. Samples were extracted using on-line solid-phase extraction followed by reversed-phase HPLC with fluorescence detection. Recoveries of 20 ng morphine and morphine glucuronides in plasma were over 95%. The limit of detection using 400 μl of a biological matrix was 0.85, 3.4 and 1.0 ng/ml of M-3-G, M-6-G and morphine, respectively. Inter- and intra-day assay precision was better than 10%. The main advantages of the present described method are increased recoveries (>95%) and a high degree of automation allowing a high speed in routine analysis. The time required for the fully automated analysis of one sample was less than 26 min.  相似文献   

2.
A heart-cut column-switching, ion-pair, reversed-phase HPLC system was used for the quantitation of efletirizine (EFZ) in biological fluids. The analyte and an internal standard (I.S.) were extracted from human EDTA plasma by C18 solid-phase extraction (SPE) using a RapidTrace® workstation. The eluent from the SPE was evaporated, reconstituted and injected onto the HPLC column. Urine samples were diluted and injected directly without the need of extraction. The compounds of interest were separated from most of the extraneous matrix materials by the first C18 column, and switched onto a second C18 column for further separation using a mobile phase of stronger eluting capability. Linearity range was 10–2000 ng ml−1 for plasma and 0.05–10 μg ml−1 for urine. The lower limit of quantitation (LOQ) was 10 ng from 1 ml of plasma, with a signal-to-noise ratio of 15:1. Inter-day precision and bias of quality control samples (QCs) were <5% for plasma and <7% for urine. Selectivity was established against six other antihistamines, three analogs of efletirizine, and on 12 control plasma lots and nine control urine lots. Recovery was 90.0% for EFZ and 89.5% for I.S. from plasma. One hundred samples can be processed in every 2.75 h on a 10-module RapidTrace® workstation with minimal human attention. Method ruggedness were tested on three brands of SPE and six different lots of one SPE brand. Performance ruggedness was demonstrated by different analysts on multiple HPLC systems. Analyte stability through sample storage, extraction process (benchtop, freeze–thaw, refrigeration after extraction) and chromatography (on-system, reinjection) was established.  相似文献   

3.
A sensitive and automated method for the separation and individual determination of tramadol enantiomers in plasma has been developed using solid-phase extraction (SPE) on disposable extraction cartridges (DECs) in combination with chiral liquid chromatography (LC). The SPE operations were performed automatically by means of a sample processor equipped with a robotic arm (ASPEC system). The DEC filled with ethyl silica (50 mg) was first conditioned with methanol and phosphate buffer, pH 7.4 A 1.0-ml volume of plasma was then applied on the DEC. The washing step was performed with the same buffer. The analytes were eluted with 0.15 ml of methanol, and 0.35 ml of phosphate buffer, pH 6.0, containing sodium perchlorate (0.2 M) were added to the extract before injection into the LC system. The enantiomeric separation of tramadol was achieved using a Chiralcel OD-R column containing cellulose tris-(3,5-dimethylphenylcarbamate) as chiral stationary phase. The mobile phase was a mixture of phosphate buffer, pH 6.0, containing sodium perchlorate (0.2 M) and acetonitrile (75:25). The mobile-phase pH and the NaClO4 concentration were optimized with respect to enantiomeric resolution. The method developed was validated. Recoveries for both enantiomers of tramadol were about 100%. The method was found to be linear in the 2.5–150 ng/ml concentration range [r2=0.999 for (+)- and (−)-tramadol]. The repeatability and intermediate precision at a concentration of 50 ng/ml were 6.5 and 8.7% for (+)-tramadol and 6.1 and 7.6% for (−)-tramadol, respectively.  相似文献   

4.
As a part of a pilot clinical study, a high-performance reversed-phase liquid chromatography analysis was developed to quantify temozolomide in plasma and urine of patients undergoing a chemotherapy cycle with temozolomide. All samples were immediately stabilized with 1 M HCl (1 + 10 of biological sample), frozen and stored at −20°C prior to analysis. The clean-up procedure involved a solid-phase extraction (SPE) of clinical sample (100 μl) on a 100-mg C18-endcapped cartridge. Matrix components were eliminated with 750 μl of 0.5% acetic acid (AcOH). Temozolomide was subsequently eluted with 1250 μl of methanol (MeOH). The resulting eluate was evaporated under nitrogen at RT and reconstituted in 200 μl of 0.5% AcOH and subjected to HPLC analysis on an ODS-column (MeOH-0.5% AcOH, 10:90) with UV detection at 330 nm. The calibration curves were linear over the concentration range 0.4–20 μg/ml and 2–150 μg/ml for plasma and urine, respectively. THe extraction recovery of temozolomide was 86–90% from plasma and 103–105% from urine over the range of concentrations considered. The stability of temozolomide was studied in vitro in buffered solutions at RT, and in plasma and urine at 37°C. An acidic pH (<5–6) shoul be maintained throughout the collection, the processing and the analysis of the sample to preserve the integrity of the drug. The method reported here was validated for use in a clinical study of temozolomide for the treatment of metastatic melanoma and high grade glioma.  相似文献   

5.
The pharmacokinetic studies of fenofibrate require a rapid, selective and robust method to allow the determination of fenofibric acid, its active metabolite, in different biological matrixes (such as plasma, serum or urine). A new fully automated method for the determination of fenofibric acid in plasma has been developed, which involves the solid-phase extraction (SPE) of the analyte from plasma on disposable extraction cartridges (DECs) and reversed-phase HPLC with UV detection. The SPE operations were performed automatically by means of a sample processor equipped with a robotic arm (ASPEC system). The DEC filled with octadecyl silica was first conditioned with methanol and pH 7.4 phosphate buffer. A 0.8-ml volume of diluted plasma sample containing the internal standard (sulindac) was then applied on the DEC. The washing step was performed with the same buffer (pH 7.4). Finally, the analytes were successively eluted with methanol (1.0 ml) and 0.04 M phosphoric acid (1.0 ml). After a mixing step, 100 μl of the resultant extract was directly introduced into the HPLC system. The liquid chromatographic (LC) separation of the analytes was achieved on a Nucleosil RP-8 stationary phase (5 μm). The mobile phase consisted of a mixture of methanol and 0.04 M phosphoric acid (60:40, v/v). The analyte was monitored photometrically at 288 nm. The method developed was validated. In these conditions, the absolute recovery of fenofibric acid was close to 100% and a linear calibration curve was obtained in the concentration range from 0.25 to 20 μg/ml. The mean RSD values for repeatability and intermediate precision were 1.7 and 3.9% for fenofibric acid. The method developed was successfully used to investigate the bioequivalence between a micronized fenofibrate capsule formulation and a fenofibrate Lidose™ formulation.  相似文献   

6.
Enantioselective separations on chiral stationary phases with or without derivatization were developed and compared for the HPLC analysis of (+)-(R)- and (-)-(S)-metoprolol acidic metabolite in human plasma and urine. The enantiomers were analysed in plasma and urine without derivatization on a Chiralcel OD-R column, and in urine after derivatization using methanol in acidic medium on a Chiralcel OD-H column. The quantitation limits were 17 ng of each enantiomer/ml plasma and 0.5 microgram of each enantiomer/ml urine using both methods. The confident limits show that the methods are compatible with pharmacokinetic investigations of the enantioselective metabolism of metoprolol. The methods were employed in a metabolism study of racemic metoprolol administered to a patient phenotyped as an extensive metabolizer of debrisoquine. The enantiomeric ratio (+)-(R)/(-)-(S)-acid metabolite was 1.1 for plasma and 1.2 for urine. Clearances were 0.41 and 0.25 l/h/kg, respectively, for the (+)-(R)- and (-)-(S)-enantiomers. The correlation coefficients between the urine concentrations of the acid metabolite enantiomers obtained by the two methods were >0.99. The two methods demonstrated interchangeable application to pharmacokinetics.  相似文献   

7.
A rapid, sensitive and robust sample preparation procedure for the quantitative determination of indinavir in human cerebrospinal fluid (CSF) and plasma is described. Indinavir and the internal standard were isolated from CSF or plasma samples by cation-exchange solid-phase extraction with SCX cartridges, while the chromatographic separation was adopted from a previous method, using a cyano column connected by a switching valve to a C18 column. UV detection was set at 210 nm. The standard curve was linear over the concentration range of 2 to 2000 ng/ml in CSF and 5 to 2000 ng/ml in plasma. The intra-day coefficients of variation at all concentration levels were ≤5.9%. The inter-day consistency was assessed by running QC samples during each daily run. The coefficients of variation for quality control samples in both matrixes were ≤6.1%. The method has been utilized to support clinical pharmacokinetic studies.  相似文献   

8.
A sensitive high-performance liquid chromatographic method for determination of intact glibenclamide in human plasma has been developed. Sample clean-up prior to chromatographic analysis was accomplished by extraction of the drug using a solid-phase RP-8 or RP-18 cartridge instead of the conventional liquid-liquid extraction methods described. For the separation of the drug from the endogenous components a reversed-phase column (LiChrosorb RP-8) of 5 μm particle size and 250×4 mm I.D., together with a mobile phase consisting of acetonitrile-12 μM perchloric acid (47:53) was selected. The method employs progesterone as an internal standard, and a reversed-phase column combined with UV detection of the drug at 230 nm. The detector response was linear up to the concentration of 400 ng/ml and the average recovery was 100.36%. The sensitivity of the method was 5 ng/ml.  相似文献   

9.
A high-performance liquid chromatographic method has been developed for the determination of penicillin-V concentrations between 0.1 and 19 μg/ml in human plasma. Penicillin-V was isolated from plasma by solid-phase extraction on a C18/OH cartridge. The extracts were injected onto a reversed-phase HPLC system. A 125×4 mm C18 column was used to separate penicillin-V from its main metabolites, 5R- and 5S-penicilloic acid and endogenous compounds. The eluent consisted of 66% 0.02 M phosphoric acid buffer, to which tetrabutylammonium dihydrogenphosphate and 34% acetonitrile were added. The column effluent was monitored by ultraviolet spectrophotometry at 269 nm. Using this method, penicillin-V concentrations in plasma could be determined with an accuracy between −5.4 and 5.2% and a precision between 0.8 and 1.6%. The method has proved to be reliable and was used in biovailability studies for the development of a new oral penicillin-V formulation.  相似文献   

10.
A fully automated chromatographic method including on-line blood serum or plasma clean-up, isocratic high-performance liquid chromatography (HPLC) and spectrophotometric detection was developed for quantitative analysis of the new antipsychotic drug amisulpride. After injection of serum or plasma onto the HPLC system and clean-up on a pre-column (10x4.0 mm I.D.) filled with Silica CN 20 micrometer (pore size 10 nm) by an eluent consisting of 8% acetonitrile in deionized water, the chromatographic separation was performed on Lichrospher CN (5 micrometer; 250x4.6 mm I.D.) by an eluent consisting of 50% acetonitrile and 50% aqueous potassium phosphate buffer (0.008 M, pH 6.4). The UV detector was set at 254 nm. The limit of quantification was about 10 microgram/l. The method revealed linearity between 10 and 600 microgram/l (correlation coefficients R(2)>0.9996). The inter-assay reproducibility (coefficient of variation) of quality control samples was between 2.8 and 11.3%. Inaccuracy was between -0.6 and +9.1%. The performance of daily calibration standards revealed an imprecision always below 15% and maximum inaccuracy of 7.7%. The method can be applied to therapeutic drug monitoring as well as pharmacokinetic studies of amisulpride.  相似文献   

11.
An HPLC method for determining quercetin in human plasma and urine is presented for application to the pharmacokinetic study of rutin. Isocratic reversed-phase HPLC was employed for the quantitative analysis by using kaempferol as an internal standard. Solid-phase extraction was performed on an Oasis HLB cartridge (>95% recovery). The HPLC assay was carried out using a Luna ODS-2 column (150 x 2.1 mm I.D., 5 microm particle size). The mobile phase was acetonitrile-10 mM ammonium acetate solution containing 0.3 mM EDTA-glacial acetic acid, 29:70:1 (v/v, pH 3.9) and 26:73:1 (v/v, pH 3.9) for the determination of plasma and urinary quercetin, respectively. The flow-rate was 0.3 ml/min and the detection wavelength was set at 370 nm. Calibration of the overall analytical procedure gave a linear signal (r>0.999) over a concentration range of 4-700 ng/ml of quercetin in plasma and 20-1000 ng/ml of quercetin in urine. The lower limit of quantification was approximately 7 ng/ml of quercetin in plasma and approximately 35 ng/ml in urine. The detection limit (defined at a signal-to-noise ratio of about 3) was approximately 0.35 ng/ml in plasma and urine. A preliminary experiment to investigate the plasma concentration and urinary excretion of quercetin after oral administration of 200 mg of rutin to a healthy volunteer demonstrated that the present method was suitable for determining quercetin in human plasma and urine.  相似文献   

12.
An HPLC method for determining a flavonoid naringin and its metabolite, naringenin, in human urine is presented for application to the pharmacokinetic study of naringin. Isocratic reversed-phase HPLC was employed for the quantitative analysis by using hesperidin for naringin or hesperetin for naringenin as internal standard and solid-phase extraction using a strong anion exchanger, Sep-Pak Accell QMA cartridge. The HPLC assay was carried out using an Inertsil ODS-2 column (250×4.6 mm I.D., 5 μm particle size). The mobile phases were acetonitrile–0.1 M ammonium acetate–acetic acid (18:81:1, v/v; pH 4.7) for naringin and acetonitrile–0.1 M ammonium acetate–triethylamine (25:75:0.05; v/v; pH 8.0) for naringenin. The flow-rate was 1.0 ml min−1. The analyses were performed by monitoring the wavelength of maximum UV absorbance at 282 nm for naringin and at 324 nm for naringenin. The lower limits of quantification were ca. 25 ng/ml for naringin and naringenin with R.S.D. less than 10%. The lower limits of detection (defined as a signal-to-noise ratio of about 3) were approximately 5 ng for naringin and 1 ng for naringenin. A preliminary experiment to investigate the urinary excretion of naringin, naringenin and naringenin glucuronides after oral administration of 500 mg of naringin to a healthy volunteer demonstrated that the present method was suitable for determining naringin and naringenin in human urine.  相似文献   

13.
Enantiomers of salbutamol were directly separated (Rs=1.16) and quantitated at therapeutic concentrations after solid-phase extraction from human plasma and urine by normal-phase high-performance liquid chromatography on a chiral column with fluorescence detection. The assay was linear for each enantiomer between 1.25 and 500 ng ml−1 and had a minimum limit of detection of 250 pg ml−1. A 3-ml plasma or 1-ml urine sample was required for quantitation at therapeutic doses. Inter-day variation was 50% for S-(+)- and 6.5% for R-(−)-salbutamol. The assay was used to compare enantioselective disposition after single doses of racemate by the intravenous, oral and rectal routes.  相似文献   

14.
Two modifications of the HPLC–ED method with respect to extraction procedure used have been developed for psilocin, the active metabolite of psilocybin, in human plasma using either liquid–liquid extraction (LLE) or automated on-line solid-phase extraction (on-line SPE). Each type of the sample preparation required a different HPLC system followed by electrochemical detection at 650 to 675 mV. The limit of quantitation of both modifications was 10 ng/ml psilocin. There was no significant difference observable between the LLE and the on-line SPE in terms of method standard deviation (LLE 1.82%, on-line SPE 1.13%) and the analytical results. However, the advantages of on-line SPE in addition to different selectivity were less manual effort, smaller plasma volumes of 400 μl (LLE 2 ml) and a recovery of psilocin in human plasma of nearly 100% (LLE 88%). In contrast to a previous procedure both methods were rapid, simple and reliable and yielded high plasma recoveries. They were used successfully in the quantitation of psilocin in plasma samples obtained from healthy volunteers after p.o. administration of 0.2 mg psilocybin per kg body mass. Plasma concentration curves and pharmacokinetic parameters were calculated.  相似文献   

15.
An HPLC method for the quantification of ketoprofen enantiomers in human plasma is described. Following extraction with a disposable C18 solid-phase extraction column, separation of ketoprofen enantiomers and I.S. (3,4-dimethoxy benzoic acid) was achieved using a chiral column [Chirex 3005; (R)-1-naphthylglycine 3,5-dinitrobenzoic acid] with the mobile phase, 0.02 M ammonium acetate in methanol, set at a flow-rate of 1.2 ml/min. Baseline separation of ketoprofen enantiomers and I.S., free from interferences, was achieved in less than 20 min. The calibration curves (n = 14) were linear over the concentration range of 0.16 to 5.00 μg/ml per enantiomer [mean r2 of 0.999 for both enantiomers, root mean square error were 0.015 for R(−) and 0.013 for S(+)]. The inter-day coefficient of variation for duplicate analysis of spiked samples was less than 7% and the accuracy was more than 93% over the concentration range of 0.2 to 4.0 μg/ml for individual enantiomer using 1 ml of plasma sample. This method has been applied to a pharmacokinetic study from healthy human volunteers following the administration of a ketoprofen extended release product (200 mg). This method is simple, fast and should find wide application in monitoring pharmacokinetic studies of ketoprofen.  相似文献   

16.
A simple and highly sensitive high-performance liquid chromatography (HPLC) method for the simultaneous quantitative determination of lansoprazole enantiomers and their metabolites, 5-hydroxylansoprazole enantiomers and lansoprazole sulfone, in human plasma have been developed. Chromatographic separation was achieved with a Chiral CD-Ph column using a mobile phase of 0.5M NaClO(4)-acetonitrile-methanol (6:3:1 (v/v/v)). The analysis required only 100 microl of plasma and involved a solid-phase extraction with Oasis HLB cartridge, with a high extraction recovery (>94.1%) and good selectivity. The lower limit of quantification (LOQ) of this assay was 10 ng/ml for each enantiomer of both lansoprazole and 5-hydroxylansoprazole, and 5 ng/ml for lansoprazole sulfone. The coefficient of variation of inter- and intra-day assay was <8.0% and accuracy was within 8.4% for all analytes (concentration range 10-1000 ng/ml). The linearity of this assay was set between 10 and 1000 ng/ml (r2>0.999 of the regression line) for each of the five analytes. This method is applicable for accurate and simultaneous monitoring of the plasma levels of lansoprazole enantiomers and their metabolites in the renal transplant recipients.  相似文献   

17.
Alentamol hydrobromide, (+)-2-(dipropylamino)-2,3-dihydro-1H-phenalen-5-ol monohydrobromide, is a selective dopamine agonist currently being investigated for the treatment of schizophrenia. This paper describes a reversed-phase high-performance liquid chromatographic-based method for the quantification of alentamol in blood plasma and urine. The method utilizes solid-phase extraction with carboxylic acid-derivatized silica columns. A limit of quantitation of 0.1 ng/ml in plasma was achieved by virtue of selective extraction and fluorescence detection. Example chromatograms of plasma and urine specimens from clinical trials demonstrate the utility of the method.  相似文献   

18.
A sensitive HPLC method for the quantification of praziquantel enantiomers in human serum is described. The method involves the use of a novel disc solid-phase extraction for sample clean-up prior to HPLC analysis and is also free of interference from trans-4-hydroxypraziquantel, the major metabolite of praziquantel. Chromatographic resolution of the enantiomers was performed on a reversed-phase cellulose-based chiral column (Chiralcel OJ-R) under isocratic conditions using a mobile phase consisting of 0.1 M sodium perchlorate–acetonitrile (66:34, v/v) at a flow-rate of 0.5 ml/min. Recoveries for R-(−)- and S-(+)-praziquantel enantiomers were in the range of 84–89% at 50–500 ng/ml levels. Intra-day and inter-day precisions calculated as R.S.D. were in the ranges of 3–8% and 1–8% for both enantiomers, respectively. Intra-day and inter-day accuracies calculated as percent error were in the 0.2–5% and 0.3–8% ranges for both enantiomers, respectively. Linear calibration curves were in the concentration range 10–600 ng/ml for each enantiomer in serum. The limit of quantification of each enantiomer was 10 ng/ml. The detection limit for each enantiomer in serum using a UV detector set at 210 nm was 5 ng/ml (S/N=2).  相似文献   

19.
Naturally occurring steroids such as progesterone, testosterone and 17β-estradiol were analyzed in this study. These bio-identical molecules paradoxically can be either beneficial or harmful. Unfortunately as growth promoters can be toxic and cancerogenic at elevated levels. Due to difficulty in monitoring at trace quantities of these hormones in biological matrices specific adsorption materials molecularly imprinted polymers (MIPs) were used for preconcentration and clean up in sample preparation step. A non-covalent imprinting approach was used for bulk polymerization of progesterone, testosterone and 17β-estradiol imprinted polymers. Synthesis of MIPs was achieved by thermal, UV and γ irradiation initiated polymerization whereby were used methacrylic acid (MAA), 4-vinylpyridine (4-VP) as functional monomers, ethylene glycol dimethacrylate (EDMA), trimethylolpropane trimethacrylate (TRIM) as cross-linking agents and acetonitrile, isooctane–toluene (1:99, v/v) and chloroform as porogen solvents. It was also used as initiator 2,2′-azobis(2-methylpropionitrile) (AIBN) or benzyl methyl ether (BME). The MIPs were applied as selective sorbents in solid-phase extraction (SPE). Molecularly imprinted solid-phase extraction (MISPE) considered as hyphenated technique were applied in extraction step before HPLC-DAD analysis of steroids from human urine.  相似文献   

20.
A novel high-performance liquid chromatographic (HPLC) method for the quantification of diclofenac in human plasma was set up. Samples, added with ibuprofen (used as internal standard) were purified by solid-phase extraction using Abselut Nexus cartridges (Varian) not requiring pre-conditioning. Drugs of interest were eluted directly into the autosampler vials and injected. The recovery of diclofenac was 92%, the analysis lasted 7 min with a sensitivity of 5 ng/ml and intra- and inter-day RSDs of 3 and 8%, respectively. The pharmacokinetics of diclofenac after oral and rectal administration in 10 healthy volunteers are reported.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号