首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A quantitative and highly sensitive method for the analysis of glycosaminoglycan (GAG)-derived disaccharides that relies on capillary electrophoresis (CE) with laser-induced fluorescence detection is presented. This method enables complete separation of 17 GAG-derived disaccharides in a single run. Unsaturated disaccharides were derivatized with 2-aminoacridone to improve sensitivity. The limit of detection was at the attomole level and approximately 100-fold more sensitive than traditional CE-ultraviolet detection. A CE separation timetable was developed to achieve complete resolution and shorten analysis time. The relative standard deviations of migration time and peak areas at both low and high concentrations of unsaturated disaccharides are all less than 2.7 and 3.2%, respectively, demonstrating that this is a reproducible method. This analysis was successfully applied to cultured Chinese hamster ovary cell samples for determination of GAG disaccharides. The current method simplifies GAG extraction steps and reduces inaccuracy in calculating ratios of heparin/heparan sulfate to chondroitin sulfate/dermatan sulfate resulting from the separate analyses of a single sample.  相似文献   

2.
DNA amplification technology has been applied to clinical diagnosis of infectious disease, genetic disorder, and cancer. After in vitro amplification of a particular DNA region, the methods of analysis for these amplified samples play a pivotal role in clinical diagnosis. Conventional gel electrophoresis has been routinely used in the lab for checking DNA. The whole procedure is time consuming and requires more than 1 ng of DNA for detection. To achieve greater performance in DNA diagnosis, we demonstrated capillary electrophoresis with laser induced fluorescence detection for analysis of amplified DNA. The analysis of DNA could be completed within 3 min and the data is directly entered into the computer. Considering the automatic and rapid process, we believe that this method could be routinely utilized for the clinical diagnosis of amplified DNA products.  相似文献   

3.
Damage to cellular DNA is implicated in the early stages of carcinogenesis and in the cytotoxicity of many anticancer agents, including ionizing radiation. Sensitive techniques are required for measuring cellular levels of DNA damage. We describe in detail a novel immunoassay that makes use of the resolving power of capillary electrophoresis and the sensitivity of laser-induced fluorescence detection. An example is given of the detection of thymine glycol in DNA produced by irradiation of human cells with a clinical dose of 2 Gy. A detection limit of approximately 10(-21) mol allowed us to monitor the repair of the lesion and to suggest that the cellular repair response may be inducible.  相似文献   

4.
Bacterial plasmids and the chromosomal DNA of many organisms adopt naturally the negatively supercoiled conformation. Therefore, the irradiation of such plasmids could be used to model conformational changes of chromosomal DNA associated with externally-induced damage. We have applied dynamic size-sieving capillary electrophoresis (CE) to monitor the damage of three DNA plasmids, over an unprecedented base pair (bp) size range (2870–27 500 bp), upon exposure to γ-radiation (20–400 Gy). Predominantly, CE with UV absorbance detection in the absence of DNA intercalating dyes was employed to preclude undesirable, induced plasmid conformational changes. Plasmid samples and their enzymatic digestion products were analyzed using both CE and slab gel electrophoresis (SGE) in order to verify the conformation of sample components. Relative to SGE, CE analyses revealed more fine structural features of plasmid degradation.  相似文献   

5.
The utility of capillary electrophoresis (CE) has been demonstrated for the analysis of secretory immunoglobulin A (sIgA) in human saliva. The amount of sIgA in saliva correlates with immune status. For detecting salivary sIgA, laser-induced fluorescence was conducted in this report for signal amplification. sIgA and anti-sIgA antibody were labeled with cyanine fluorescence (Cy5) for competitive immunoassay and non-competitive analysis, respectively. Cy5 was excited by He-Ne laser with a wavelength of 635 nm, with maximum emission at 670 nm. Migration time during electrophoresis depended on whether sIgA-Cy5 was mixed with antibody or anti-sIgA-Cy5 mixed with sIgA to form Ag-Ab complex. The results indicated that CE competitive immunoassay was effective for analyzing serum sIgA, but not for salivary sIgA. However, salivary sIgA can be analyzed by complex formation assay. The peak area of the complex was proportional to the amount of sIgA added. A standard linear regression curve was generated using purified sIgA. From this standard curve, the amount of sIgA from saliva of either normal or immunocompromised patients can be calculated from the Ag-Ab complex peak area.  相似文献   

6.
A new analytical method for vigabatrin based on capillary electrophoretic separation and laser-induced fluorescence detection has been developed. 5-Carboxytetramethylrhodamine succinimidyl ester was used for precolumn derivatization of the non-fluorescent drug. Optimal separation and detection were obtained with an electrophoretic buffer of 50 mM sodium borate (pH9.5) containing 10 mM sodium dodecyl sulfate and a green He-Ne laser (excitation at 543.5 nm, emission at 589 nm). The concentration limit of detection in aqueous solution was 24 nM. Combined with a simple cleanup procedure, this method can be applied to the determination of vigabatrin in human plasma. A calibration curve ranging from 1.5 to 200 microM shown to be linear. Both the within-day and day-to-day reproducibilities and accuracies were less then 14.3% and 4.9% respectively. The limit of detection of vigabatrin in plasma was about 0.13 microM  相似文献   

7.
Automation is essential for rapid genetic-based mutation analysis in clinical laboratory to screen a large number of DNA samples. We propose in this report an automatic process using Beckman Coulter P/ACE™ capillary electrophoresis (CE) with laser-induced fluorescence (LIF) system to detect a single-point mutation in the codon 12 of human K-ras gene. Polymerase chain reaction (PCR) using a fluorescently labeled reverse primer and a plain forward primer to specifically amplify a selected 50 bp DNA fragment in human K-ras gene. The amplified DNA is placed on the sample tray of the CE system with a pre-programmed step for single-strand conformation polymorphism (SSCP) analysis. Sample injection and denaturation processes are performed online along with separation and real-time data analysis. The concept of automation for rapid DNA mutation analysis using CE-LIF system for SSCP is presented.  相似文献   

8.
The quantification of insulin released from single cells of the insulin-secreting cell line βTC3 permeabilized by digitonin is demonstrated. A simple method for monitoring the on-column release process by using capillary electrophoresis and laser-induced native fluorescence detection is described. Quantitative measurements of both the amount of insulin released and the amount remaining in the cell can be achieved simultaneously. This protocol provides an alternative approach to the study of cell secretion in the fields of neuroscience and endocrinology.  相似文献   

9.
A newly developed capillary electrophoretic method using laser-induced fluorescence detection (CE-LIF) for the analysis of monosaccharides released from acid hydrolysis of glycosaminoglycans was studied. The method was compared with a previously published method using indirect LIF detection (CE-ILIF). For the CE-LIF method, electrophoretic conditions for the separation of the monosaccharides derivatised with 8-aminopyrene-1,3,6-trisulfonate (APTS) were optimised. The best separations were obtained using 100 mM acetate at pH 4.5 as running buffer. The influence of the injection vial volume on the precision and stability of the sample in different conditions was studied. The detection limits of the CE-LIF method were found to be 0.4-0.6 nM, while those obtained by CE-ILIF ranged from 11.4 to 14.3 microM. Other quality parameters of the method, such as run-to-run precision, day-to-day precision, and linearity were also determined. Finally, the new method was applied to the analysis of the acid hydrolysis products from a glucosaminoglycan (heparin) and a galactosaminoglycan (dermatan sulfate) and cross-contamination between the two solutions was determined. The high sensitivity of the new method allows the determination of dermatan sulfate contaminations in a heparin raw sample down to 0.04% (w/w) and broadens the practical applicability of CE-LIF for the quantitation of the endogenous levels of glycosaminoglycans in animal samples and for pharmacokinetic control after therapeutical heparin administration.  相似文献   

10.
11.
D-Penicillamine (D-Pen) is a thiol drug used in the treatment of Wilson's disease, rheumatoid arthritis, metal intoxication and cystinuria. We have recently described a new capillary electrophoresis (CE) method to measure physiological thiols, in which separation of total plasma homocysteine, cysteine, cysteinylglycine, glutathione is achieved using the organic base N-methyl-D-glucamine in the run buffer. In this paper, we present an improvement of our method that allows a baseline separation of total plasma D-Pen from the physiological thiols. Moreover, reduced, free and protein-bound forms of drug are measured by varying the order of disulfide reduction with tributylphosphine and proteins precipitation with 5-sulphosalicylic acid (SSA). After derivatization with 5-iodoacetamidofluorescein (5-IAF), samples are separated and measured by capillary electrophoresis with laser-induced fluorescence in an uncoated fused-silica capillary (57 x 75 microm i.d.) using a phosphate/borate run buffer pH 11.4. In these conditions, the migration time of D-Pen is about 7 min and the time required for each analysis is roughly 10 min. The proposed method has been utilized to measure the various forms of the drug in a D-Pen administered Wilson's disease patient.  相似文献   

12.
Capillary electrophoresis (CE) with HeCd laser-induced fluorescence (LIF) detection and its application in forensic toxicology is demonstrated by the determination of

-lysergic acid diethylamide (LSD) in blood. Following precipitation of proteins, washing of the evaporated supernatant and extraction, the residue was reconstituted in methanol and injected electrokinetically (10 s, 10 kV). The total analysis time for quantification of LSD was 8 min using a citrate–methanol buffer, pH 4.0. With this buffer system it is possible to separate LSD, nor-LSD, iso-LSD and iso-nor-LSD. Using a specific sample preparation, electrokinetic injection, extended light path (bubble cell) capillaries and especially LIF detection (λex 325 nm, λem 435 nm), a limit of detection of 0.1–0.2 ng LSD per ml blood could be obtained. The limit of quantitation was about 0.4–0.5 ng/ml. The quantitative evaluation for LSD was carried out using methylergometrine as internal standard. The precision expressed as coefficient of variation (C.V.) and accuracy of the method were <20% and 86–110%, respectively. The application of the method to human blood samples from two forensic cases and a comparison with radioimmunoassay demonstrated that the results were consistent.  相似文献   

13.
HIV-1 RNA was quantitated directly by capillary electrophoresis with laser-induced fluorescence (CE-LIF). CE-LIF was used to analyze cellular RNA and various nucleotide complexes. A fluorescently labeled DNA probe (DNA/RNA complex) in conjunction with thiazole orange intercalator was determined to have optimal stability and sensitivity for RNA analysis. Based on this observation, a hybridization method using a HIV-specific fluorescently labeled probe with analysis by CE-LIF was developed. Plasma samples from a HIV-seropositive patient were lysed to obtain RNA, hybridized with the HIV-specific probe and analyzed by CE-LIF. As little as 19 fg (1710 copies per 1 ml of starting plasma) of HIV RNA can be reliably and quantitatively detected. CE-LIF appears to be an efficient and sensitive method to quantitatively analyze RNA from a variety of sources.  相似文献   

14.
The Human Genome has been sequenced in large part owing to the invention of capillary electrophoresis. Although this technology has matured enough to allow such amazing achievements, the physical mechanisms at play during separation have yet to be completely understood and optimized. Recently, new separation regimes and new physical mechanisms have been investigated. The use of free-flow electrophoresis and new modes of pulsed-field electrophoresis have been suggested, while we have observed a shift towards single nucleotide polymorphism analysis and microchip technologies. A strong theoretical basis remains essential for the efficient development of new methods.  相似文献   

15.
Capillary electrophoresis (CE) with UV laser-induced native fluorescence detection was developed as a sensitive and selective assay for the direct determination of tramadol in human urine without extraction or preconcentration. The main problem in CE is the small inner diameter of the capillary which causes a low sensitivity with instruments equipped with a UV detector. Laser-induced native fluorescence with a frequency doubled argon ion laser at an excitation wavelength of 257 nm was used for the direct assay of tramadol in urine to enhance the limit of detection about 1000-fold compared to UV absorption detection. The detection system consists of an imaging spectrograph and an intensified CCD camera, which views an illuminated 1.5 mm section of the capillary. This set-up is able to record the whole emission spectra of the analytes to achieve additionally wavelength-resolved electropherograms. In the concentration range of 20 ng/ml–5 μg/ml in human urine coefficients of correlation were better than 0.998. Within-day variation determined on four different concentrations showed accuracies ranging from 90.2 to 108.4%. The relative standard deviation (RSD) was determined to be less than 10%. Day-to-day variation presented accuracies ranging from 90.9 to 103.1% with an RSD less than 8%.  相似文献   

16.
High speed DNA sequencing by capillary electrophoresis.   总被引:3,自引:4,他引:3       下载免费PDF全文
A major challenge of the Human Genome Initiative is the development of a rapid, accurate, and efficient DNA sequencing technology. A major limitation of current technology is the relatively long time required to perform the gel electrophoretic separations of DNA fragments produced in the sequencing reactions. We demonstrate here that it is possible to increase the speed of sequence analysis by over an order of magnitude by performing the electrophoresis and detection in ultra thin capillary gels. An instrument which utilizes these high speed separations to simultaneously analyze many samples will constitute a second generation automated DNA sequencer suitable for large-scale sequence analysis.  相似文献   

17.
A method has been developed by which enzymatically incorporated fluorophore-labeled nucleotide sites in nucleic acid can be quantitated by degradation of nanogram quantities of DNA followed by capillary gel electrophoretic analysis with fluorescence detection. In this way the differing relative labeling densities achieved using either C5-substituted dUTP's or N4-substituted dCTP's were determined. The method has proven to be very useful in obtaining quantitative analytical data from the small quantities of complex molecules produced in nick translations. Various polymerization conditions using DNA polymerase I were examined to determine optimal labeling density. Simultaneous copolymerization of green fluorescing dCTP and dUTP nucleotides were undertaken in an attempt to maximize labeling density.  相似文献   

18.
A method based on capillary electrophoresis has been developed for the analysis of the novel antidepressant drug duloxetine in human plasma. The method makes use of laser-induced fluorescence detection after derivatisation of the analyte with 5-(4,6-dichlorotriazinyl)aminofluorescein at pH 11. A single step liquid/liquid extraction procedure with a mixture of hexane/2-propanol allows the sample clean-up with extraction yields always ≥84% and interference removal. The electrophoretic separation is achieved using uncoated fused silica capillaries (60.0 cm effective length, 75.0 cm total length, 50 μm internal diameter) and a background electrolyte composed of borate buffer (40 mM, pH 10.3), tetrabutylammonium bromide (10 mM), and acetone (10%, v/v). The applied voltage is 20 kV; the samples are injected by pressure (50 mbar × 8 s). The method has been fully validated in terms of linearity range (2.5–150 ng mL?1), LOD and LOQ (1.0 and 2.5 ng mL?1, respectively), precision (R.S.D. < 6.7%) and accuracy (recovery >78%). Application to samples obtained from patients under treatment with duloxetine gave good results. The method represents the first application of capillary electrophoresis to the analysis of duloxetine in human plasma.  相似文献   

19.
The LIGA (Lithographie Galvanoformung Abformung) process using synchrotron radiation lithography is applied to the microfabrication of capillary array electrophoresis (CAE) device. Laser-induced fluorescence detection system for the CAE device has been constructed by the modification of laser confocal fluorescence microscopy. DNA molecules were detected during migrating in the microchannels filled with polymer separation matrices under electric field to optimize the separation conditions for DNA analysis. Based on this observation, we demonstrated that microfabricated CAE device is realized the fast separation of DNA.  相似文献   

20.
This work deals with annealing of single-stranded DNA and the binding of a serum respond factor to a DNA probe containing specific binding site. Capillary electrophoresis (CE) method is explored and compared with the mobility-shift gel electrophoresis (GE) procedure. The results indicate the CE method offers direct and rapid annealing of the DNA strands. It requires no prior incubation with additives (polynucleotides, proteins) to reduce nonspecific DNA-protein interactions. Unwanted nonspecific interactions are not observed in the CE method. The presence of a fluorescein tag to the DNA probe yields identical results to those with the radioactive label. A fluorescein tag in the CE work can be used without any adverse effects. The dissociation constant (Kd) of this protein-DNA complex by the CE method was similar to those determined by the GE method (approximately 10(-6) M). The proposed method is extremely powerful, highly sensitive, quantitative, and fast. It can determine even very small conformational differences of the DNA probe.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号