首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《IRBM》2022,43(5):380-390
BackgroundAutism Spectrum Disorder (ASD) is a neurodevelopmental condition that is characterized by various social impairments. Children with ASD have major difficulties in expressing themselves, resulting in stress and meltdowns. Understanding their hidden feelings and needs may help in tackling and avoiding such strenuous behaviors.ObjectiveThis research aims to aid the parents and caretakers of children with ASD to understand the hidden and unexpressed emotional state by using physiological signals obtained from wearable devices.MethodsHere, electrocardiogram (ECG) signals pertaining to two valence states (‘like’ and ‘dislike’) were recorded from twenty children (10 Control and 10 children with ASD). The heart rate variability (HRV) signals were then obtained from the ECG signals using the Pan-Tompkins's algorithm. The statistical, higher order statistics (HOS) and geometrical features which were statistically significant were trained using the K Nearest Neighbor (KNN) and Ensemble Classifier algorithms.ResultsThe findings of our analysis indicate that the integration of major statistical features resulted in an overall average accuracy of 84.8% and 75.3% using HRV data for the control and test population, respectively. Similarly, geometrical features resulted in a maximum average accuracy of 84.8% and 74.2% for control and test population respectively. The decreased HRV in the test population indicates the presence of autonomic dysregulation in children with ASD when compared to their control peers.  相似文献   

2.
《IRBM》2021,42(6):466-473
ObjectiveIn the last few decades, the consumption of cannabis-based products for recreational purposes has dramatically increased. Unfortunately, cannabis consumption has been associated with the incidences of cardiovascular diseases. Hence, there is a necessity for understanding the plausible mechanics of cardiophysiological changes due to cannabis consumption. Accordingly, the current study was designed to understand the suitability of the recurrence quantification analysis (RQA) method in detecting the changes in the heart rate variability (HRV) time-series signals due to the consumption of cannabis (bhang). Further, a machine learning model has been proposed for the automated detection of the cannabis takers.Materials and MethodsThe RQA of the HRV time-series signals from 200 healthy Indian male paddy-field workers were carried out. The obtained parameters were statistically analyzed using the Mann-Whitney U test. Further, the decision trees, weight-based feature ranking, and dimensionality reduction methods were employed for identifying the relevant features for the development of a suitable machine learning model.ResultsObservable changes in the patterns of the recurrence plots among the bhang consuming and non-consuming groups were noticed. However, there were no significant differences in the RQA parameters. Among the developed machine learning models, the SVM model obtained from the “Information gain ratio” feature selection method exhibited the highest accuracy (%) of 69.09 ± 9.33.ConclusionOur study suggests that the RQA method is not as effective as the time and frequency domain methods for detecting the alterations in the HRV time-series signals due to cannabis consumption. The SVM model was found to be the best model for the automated detection of cannabis takers. The selection of the features by the information gain ratio method played an important role in the development of the optimized SVM model.  相似文献   

3.
Statistical, spectral, multi-resolution and non-linear methods were applied to heart rate variability (HRV) series linked with classification schemes for the prognosis of cardiovascular risk. A total of 90 HRV records were analyzed: 45 from healthy subjects and 45 from cardiovascular risk patients. A total of 52 features from all the analysis methods were evaluated using standard two-sample Kolmogorov-Smirnov test (KS-test). The results of the statistical procedure provided input to multi-layer perceptron (MLP) neural networks, radial basis function (RBF) neural networks and support vector machines (SVM) for data classification. These schemes showed high performances with both training and test sets and many combinations of features (with a maximum accuracy of 96.67%). Additionally, there was a strong consideration for breathing frequency as a relevant feature in the HRV analysis.  相似文献   

4.
《IRBM》2019,40(3):157-166
ObjectiveFetal Electro Cardiogram (fECG) provides critical information on the wellbeing of a foetus heart in its developing stages in the mother's womb. The objective of this work is to extract fECG which is buried in a composite signal consisting of itself, maternal ECG (mECG) and noises contributed from various unavoidable sources. In the past, the challenge of extracting fECG from the composite signal was dealt with by Stochastic Weiner filter, model-based Kalman filter and other adaptive filtering techniques. Blind Source Separation (BSS) based Independent Component Analysis (ICA) has shown an edge over the adaptive filtering techniques as the former does not require a reference signal. Recently, data-driven machine learning techniques e.g., adaptive neural networks, adaptive neuro-fuzzy inference system, support vector machine (SVM) are also applied.MethodThis work pursues hidden Markov model (HMM)-based supervised machine learning frame-work for the determination of the location of fECG QRS complex from the composite abdominal signal. HMM is used to model the underlying hidden states of the observable time series of the extracted and separated fECG data with its QRS peak location as one of the hidden states. The state transition probabilities are estimated in the training phase using the annotated data sets. Afterwards, using the estimated HMM networks, fQRS locations are detected in the testing phase. To evaluate the proposed technique, the accuracy of the correct detection of QRS complex with respect to the correct annotation of QRS complex location is considered and quantified by the sensitivity, probability of false alarm, and accuracy.ResultsThe best results that have been achieved using the proposed method are: accuracy – 97.1%, correct detection rate (translated to sensitivity) – 100%, and false alarm rate – 2.89%.ConclusionTwo primary challenges in these methods are finding the right reference threshold for the normalization of the extracted fECG signal during the initial trials and limitation of discrete frame work of HMM signal (converted from continuous time) which only offers a countable number of levels in observations. By feeding the posterior probabilities, obtained from SVM, into HMM, as emission probabilities, can further improve the accuracy of fQRS location detection.  相似文献   

5.

Background

This study proposed an effective method based on the wavelet multi-scale α-entropy features of heart rate variability (HRV) for the recognition of paroxysmal atrial fibrillation (PAF). This new algorithm combines wavelet decomposition and non-linear analysis methods. The PAF signal, the signal distant from PAF, and the normal sinus signals can be identified and distinguished by extracting the characteristic parameters from HRV signals and analyzing their quantification indexes. The original ECG signals for QRS detection and HRV signal extraction are first processed. The features from the HRV signals are extracted as feature vectors using the wavelet multi-scale entropy. A support vector machine-based classifier is used for PAF prediction.

Results

The performance of the proposed method in predicting PAF episodes is evaluated with 100 signals from the MIT-BIT PAF prediction database. With regard to the dynamics and uncertainty of PAF signals, our proposed method obtains the values of 92.18, 94.88, and 89.48% for the evaluation criteria of correct rate, sensitivity, and specificity, respectively.

Conclusions

Our proposed method presents better results than the existing studies based on time domain, frequency domain, and non-linear methods. Thus, our method shows considerable potential for clinical monitoring and treatment.
  相似文献   

6.
Developing a mathematical model for the artificial generation of electrocardiogram (ECG) signals is a subject that has been widely investigated. One of the challenges is to generate ECG signals with a wide range of waveforms, power spectra and variations in heart rate variability (HRV)--all of which are important indexes of human heart functions. In this paper we present a comprehensive model for generating such artificial ECG signals. We incorporate into our model the effects of respiratory sinus arrhythmia, Mayer waves and the important very low-frequency component in the power spectrum of HRV. We use a new modified Zeeman model for generating the time series for HRV, and a single cycle of ECG is produced by using a simple neural network. The importance of the work is the model's ability to produce artificial ECG signals that resemble experimental recordings under various physiological conditions. As such the model provides a useful tool to simulate and analyse the main characteristics of ECG, such as its power spectrum and HRV under different conditions. Potential applications of this model include using the generated ECG as a flexible signal source to assess the effectiveness of a diagnostic ECG signal-processing device.  相似文献   

7.
《IRBM》2019,40(3):145-156
ObjectiveElectrocardiogram (ECG) is a diagnostic tool for recording electrical activities of the human heart non-invasively. It is detected by electrodes placed on the surface of the skin in a conductive medium. In medical applications, ECG is used by cardiologists to observe heart anomalies (cardiovascular diseases) such as abnormal heart rhythms, heart attacks, effects of drug dosage on subject's heart and knowledge of previous heart attacks. Recorded ECG signal is generally corrupted by various types of noise/distortion such as cardiac (isoelectric interval, prolonged depolarization and atrial flutter) or extra cardiac (respiration, changes in electrode position, muscle contraction and power line noise). These factors hide the useful information and alter the signal characteristic due to low Signal-to-Noise Ratio (SNR). In such situations, any failure to judge the ECG signal correctly may result in a delay in the treatment and harm a subject (patient) health. Therefore, appropriate pre-processing technique is necessary to improve SNR to facilitate better treatment to the subject. Effects of different pre-processing techniques on ECG signal analysis (based on R-peaks detection) are compared using various Figures of Merit (FoM) such as sensitivity (Se), accuracy (Acc) and detection error rate (DER) along with SNR.MethodsIn this research article, a new fractional wavelet transform (FrWT) has been proposed as a pre-processing technique in order to overcome the disadvantages of other existing commonly used techniques viz. wavelet transform (WT) and the fractional Fourier transform (FrFT). The proposed FrWT technique possesses the properties of multiresolution analysis and represents signal in the fractional domain which consists of representation in terms of rotation of signals in the time–frequency plane. In the literature, ECG signal analysis has been improvised using statistical pre-processing techniques such as principal component analysis (PCA), and independent component analysis (ICA). However, both PCA and ICA are prone to suffer from slight alterations in either signal or noise, unless the basis functions are prepared with a worldwide set of ECG. Independent Principal Component Analysis (IPCA) has been used to overcome this shortcoming of PCA and ICA. Therefore, in this paper three techniques viz. FrFT, FrWT and IPCA are selected for comparison in pre-processing of ECG signals.ResultsThe selected methods have been evaluated on the basis of SNR, Se, Acc and DER of the detected ECG beats. FrWT yields the best results among all the methods considered in this paper; 34.37dB output SNR, 99.98% Se, 99.96% Acc, and 0.036% DER. These results indicate the quality of biology-related information retained from the pre-processed ECG signals for identifying different heart abnormalities.ConclusionCorrect analysis of the acquired ECG signal is the main challenge for cardiologist due to involvement of various types of noises (high and low frequency). Twenty two real time ECG records have been evaluated based on various FoM such as SNR, Se, Acc and DER for the proposed FrWT and existing FrFT and IPCA preprocessing techniques. Acquired real-time ECG database in normal and disease situations is used for the purpose. The values of FoMs indicate high SNR and better detection of R-peaks in a ECG signal which is important for the diagnosis of cardiovascular disease. The proposed FrWT outperforms all other techniques and holds both analytical attributes of the actual ECG signal and alterations in the amplitudes of various ECG waveforms adequately. It also provides signal portrayals in the time-fractional-frequency plane with low computational complexity enabling their use practically for versatile applications.  相似文献   

8.
This paper proposes a new power spectral-based hybrid genetic algorithm-support vector machines (SVMGA) technique to classify five types of electrocardiogram (ECG) beats, namely normal beats and four manifestations of heart arrhythmia. This method employs three modules: a feature extraction module, a classification module and an optimization module. Feature extraction module extracts electrocardiogram's spectral and three timing interval features. Non-parametric power spectral density (PSD) estimation methods are used to extract spectral features. Support vector machine (SVM) is employed as a classifier to recognize the ECG beats. We investigate and compare two such classification approaches. First they are specified experimentally by the trial and error method. In the second technique the approach optimizes the relevant parameters through an intelligent algorithm. These parameters are: Gaussian radial basis function (GRBF) kernel parameter σ and C penalty parameter of SVM classifier. Then their performances in classification of ECG signals are evaluated for eight files obtained from the MIT–BIH arrhythmia database. Classification accuracy of the SVMGA approach proves superior to that of the SVM which has constant and manually extracted parameter.  相似文献   

9.
《IRBM》2020,41(1):58-70
ObjectivesObjective of this paper is to present a reliable and accurate technique for Myocardial Infarction (MI) detection and localization.Material and methodsStationary wavelet transform has been used to decompose the ECG signal. Energy, entropy and slope based features were extracted at specific wavelet bands from selected lead of ECG. k-Nearest Neighbors (kNN) with Mahalanobis distance function has been used for classification. Sensitivity (Se), specificity (Sp), positive predictivity (+P), accuracy (Acc), and area under the receiver operating characteristics curve (AUC) analyzed over 200 subjects (52 health control, 148 with MI) from Physikalisch-Technische Bundesanstalt (PTB) database has been used for performance analysis. To handle the imbalanced data adaptive synthetic (ADASYN) sampling approach has been adopted.ResultsFor detection of MI, the proposed technique has shown an AUC = 0.99, Se = 98.62%, Sp = 99.40%, PPR = 99.41% and Acc = 99.00% using 12 top ranked features, extracted from multiple leads of ECG and AUC = 0.99, Se = 98.34%, Sp = 99.77%, PPR = 99.77% and Acc = 99.05% using 12 features extracted from a single ECG lead (i.e. lead V5). For localization of MI, the proposed technique has an AUC = 0.99, Se = 98.78%, Sp = 99.86%, PPR = 98.80%, and Acc = 99.76% using 5 top ranked features from multiple leads of ECG and AUC = 0.98, Se = 96.47%, Sp = 99.60%, PPR = 96.49% and Acc = 99.28% using 8 features extracted from a single ECG lead (i.e. lead V3).ConclusionThus for MI detection and localization, the proposed technique is independent of time-domain ECG fiducial markers and can work using specific leads of ECG.  相似文献   

10.
IntroductionCardiovascular dysautonomia comprising postural orthostatic tachycardia syndrome (POTS) and orthostatic hypotension (OH) is one of the presentations in COVID-19 recovered subjects. We aim to determine the prevalence of cardiovascular dysautonomia in post COVID-19 patients and to evaluate an Artificial Intelligence (AI) model to identify time domain heart rate variability (HRV) measures most suitable for short term ECG in these subjects.MethodsThis observational study enrolled 92 recently COVID-19 recovered subjects who underwent measurement of heart rate and blood pressure response to standing up from supine position and a 12-lead ECG recording for 60 s period during supine paced breathing. Using feature extraction, ECG features including those of HRV (RMSSD and SDNN) were obtained. An AI model was constructed with ShAP AI interpretability to determine time domain HRV features representing post COVID-19 recovered state. In addition, 120 healthy volunteers were enrolled as controls.ResultsCardiovascular dysautonomia was present in 15.21% (OH:13.04%; POTS:2.17%). Patients with OH had significantly lower HRV and higher inflammatory markers. HRV (RMSSD) was significantly lower in post COVID-19 patients compared to healthy controls (13.9 ± 11.8 ms vs 19.9 ± 19.5 ms; P = 0.01) with inverse correlation between HRV and inflammatory markers. Multiple perceptron was best performing AI model with HRV(RMSSD) being the top time domain HRV feature distinguishing between COVID-19 recovered patients and healthy controls.ConclusionPresent study showed that cardiovascular dysautonomia is common in COVID-19 recovered subjects with a significantly lower HRV compared to healthy controls. The AI model was able to distinguish between COVID-19 recovered patients and healthy controls.  相似文献   

11.
PurposeCardiovascular disease (CVD) is a leading cause of death globally. Electrocardiogram (ECG), which records the electrical activity of the heart, has been used for the diagnosis of CVD. The automated and robust detection of CVD from ECG signals plays a significant role for early and accurate clinical diagnosis. The purpose of this study is to provide automated detection of coronary artery disease (CAD) from ECG signals using capsule networks (CapsNet).MethodsDeep learning-based approaches have become increasingly popular in computer aided diagnosis systems. Capsule networks are one of the new promising approaches in the field of deep learning. In this study, we used 1D version of CapsNet for the automated detection of coronary artery disease (CAD) on two second (95,300) and five second-long (38,120) ECG segments. These segments are obtained from 40 normal and 7 CAD subjects. In the experimental studies, 5-fold cross validation technique is employed to evaluate performance of the model.ResultsThe proposed model, which is named as 1D-CADCapsNet, yielded a promising 5-fold diagnosis accuracy of 99.44% and 98.62% for two- and five-second ECG signal groups, respectively. We have obtained the highest performance results using 2 s ECG segment than the state-of-art studies reported in the literature.Conclusions1D-CADCapsNet model automatically learns the pertinent representations from raw ECG data without using any hand-crafted technique and can be used as a fast and accurate diagnostic tool to help cardiologists.  相似文献   

12.
目的:探讨基于多尺度快速样本熵与随机森林的心电图分析方法对常见心律失常(房性早搏、室性早搏)的自动诊断的可行性和有效性。方法:利用不同心律失常疾病的心电信号存在复杂性差异的特点,通过多尺度熵计算心电信号在不同尺度下的样本熵值以组成特征向量;利用kd树提高多尺度熵的计算效率,增强算法的实时性。利用训练样本的特征向量构建随机森林分类器,再根据众多决策树的分类结果结合投票原则确定测试样本心律失常疾病的类型。结果:本文提出的心电图分析方法能够有效地识别正常心律、房性早搏(APB)及室性早搏(VPB),平均识别准确率达到91.60%。结论:本文提出的心电图分析方法对常见心律失常(APB,VPB)具有较高的识别准确率及临床实用价值。  相似文献   

13.
《IRBM》2020,41(5):252-260
ObjectiveMonitoring the heartbeat of the fetus during pregnancy is a vital part in determining their health. Current fetal heart monitoring techniques lack the accuracy in fetal heart rate monitoring and features acquisition, resulting in diagnostic medical issues. The demand for a reliable method of non-invasive fetal heart monitoring is of high importance.MethodElectrocardiogram (ECG) is a method of monitoring the electrical activity produced by the heart. The extraction of the fetal ECG (FECG) from the abdominal ECG (AECG) is challenging since both ECGs of the mother and the baby share similar frequency components, adding to the fact that the signals are corrupted by white noise. This paper presents a method of FECG extraction by eliminating all other signals using AECG. The algorithm is based on attenuating the maternal ECG (MECG) by filtering and wavelet analysis to find the locations of the FECG, and thus isolating them based on their locations. Two signals of AECG collected at different locations on the abdomens are used. The ECG data used contains MECG of a power of five to ten times that of the FECG.ResultsThe FECG signals were successfully isolated from the AECG using the proposed method through which the QRS complex of the heartbeat was conserved, and heart rate was calculated. The fetal heart rate was 135 bpm and the instantaneous heart rate was 131.58 bpm. The heart rate of the mother was at 90 bpm with an instantaneous heart rate of 81.9 bpm.ConclusionThe proposed method is promising for FECG extraction since it relies on filtering and wavelet analysis of two abdominal signals for the algorithm. The method implemented is easily adjusted based on the power levels of signals, giving it great ease of adaptation to changing signals in different biosignals applications.  相似文献   

14.
Electrocardiogram (ECG) signals are difficult to interpret, and clinicians must undertake a long training process to learn to diagnose diabetes from subtle abnormalities in these signals. To facilitate these diagnoses, we have developed a technique based on the heart rate variability signal obtained from ECG signals. This technique uses digital signal processing methods and, therefore, automates the detection of diabetes from ECG signals. In this paper, we describe the signal processing techniques that extract features from heart rate (HR) signals and present an analysis procedure that uses these features to diagnose diabetes. Through statistical analysis, we have identified the correlation dimension, Poincaré geometry properties (SD2), and recurrence plot properties (REC, DET, L mean) as useful features. These features differentiate the HR data of diabetic patients from those of patients who do not have the illness, and have been validated by using the AdaBoost classifier with the perceptron weak learner (yielding a classification accuracy of 86%). We then developed a novel diabetic integrated index (DII) that is a combination of these nonlinear features. The DII indicates whether a particular HR signal was taken from a person with diabetes. This index aids the automatic detection of diabetes, thereby allowing a more objective assessment and freeing medical professionals for other tasks.  相似文献   

15.

Background

Drosophila heart tube is a feasible model for cardiac physiological research. However, obtaining Drosophila electrocardiograms (ECGs) is difficult, due to the weak signals and limited contact area to apply electrodes. This paper presents a non-invasive Gallium-Indium (GaIn) based recording system for Drosophila ECG measurement, providing the heart rate and heartbeat features to be observed. This novel, high-signal-quality system prolongs the recording time of insect ECGs, and provides a feasible platform for research on the molecular mechanisms involved in cardiovascular diseases.

Methods

In this study, two types of electrode, tungsten needle probes and GaIn electrodes, were used respectively to noiselessly conduct invasive and noninvasive ECG recordings of Drosophila. To further analyze electrode properties, circuit models were established and simulated. By using electromagnetic shielded heart signal acquiring system, consisted of analog amplification and digital filtering, the ECG signals of three phenotypes that have different heart functions were recorded without dissection.

Results and Discussion

The ECG waveforms of different phenotypes of Drosophila recorded invasively and repeatedly with n value (n>5) performed obvious difference in heart rate. In long period ECG recordings, non-invasive method implemented by GaIn electrodes acts relatively stable in both amplitude and period. To analyze GaIn electrode, the correctness of GaIn electrode model established by this paper was validated, presenting accuracy, stability, and reliability.

Conclusions

Noninvasive ECG recording by GaIn electrodes was presented for recording Drosophila pupae ECG signals within a limited contact area and signal strength. Thus, the observation of ECG changes in normal and SERCA-depleted Drosophila over an extended period is feasible. This method prolongs insect survival time while conserving major ECG features, and provides a platform for electrophysiological signal research on the molecular mechanism involved in cardiac arrhythmia, as well as research related to drug screening and development.  相似文献   

16.
In recent years, extensive studies have been conducted on the diagnosis of Alzheimer''s disease (AD) using the non-invasive speech signal recognition method. In this study, Farsi speech signals were analyzed using the auditory model system (AMS) in order to recognize AD. For this purpose, after the pre-processing of the speech signals and utilizing AMS, 4D outputs as function of time, frequency, rate, and scale range were obtained. The AMS outcomes were averaged in term of time to analyze the rate-frequency-scale for both groups, Alzheimer''s and healthy control subjects. Thereafter, the maximum of spectral and temporal modulation and frequency were extracted to classify by the support vector machine (SVM). The SVM achieves higher promising recognition accuracy with compare to prevalent approaches in the field of speech processing. The acceptable results demonstrate the applicability of the proposed algorithm in non-invasive and low-cost recognizing Alzheimer''s only using the few extracted features of the speech signal.  相似文献   

17.
《IRBM》2022,43(2):107-113
Background and objectiveAn important task of the brain-computer interface (BCI) of motor imagery is to extract effective time-domain features, frequency-domain features or time-frequency domain features from the raw electroencephalogram (EEG) signals for classification of motor imagery. However, choosing an appropriate method to combine time domain and frequency domain features to improve the performance of motor imagery recognition is still a research hotspot.MethodsIn order to fully extract and utilize the time-domain and frequency-domain features of EEG in classification tasks, this paper proposed a novel dual-stream convolutional neural network (DCNN), which can use time domain signal and frequency domain signal as the inputs, and the extracted time-domain features and frequency-domain features are fused by linear weighting for classification training. Furthermore, the weight can be learned by the DCNN automatically.ResultsThe experiments based on BCI competition II dataset III and BCI competition IV dataset 2a showed that the model proposed by this study has better performance than other conventional methods. The model used time-frequency signal as the inputs had better performance than the model only used time-domain signals or frequency-domain signals. The accuracy of classification was improved for each subject compared with the models only used one signals as the inputs.ConclusionsFurther analysis shown that the fusion weight of different subject is specifically, adjusting the weight coefficient automatically is helpful to improve the classification accuracy.  相似文献   

18.
Signals from different systems are analyzed during sleep on a beat-to-beat basis to provide a quantitative measure of synchronization with the heart rate variability (HRV) signal, oscillations of which reflect the action of the autonomic nervous system. Beat-to-beat variability signals synchronized to QRS occurrence on ECG signals were extracted from respiration, electroencephalogram (EEG) and electromyogram (EMG) traces. The analysis was restricted to sleep stage 2. Cyclic alternating pattern (CAP) periods were detected from EEG signals and the following conditions were identified: stage 2 non-CAP (2 NCAP), stage 2 CAP (2 CAP) and stage 2 CAP with myoclonus (2 CAP MC). The coupling relationships between pairs of variability signals were studied in both the time and frequency domains. Passing from 2 NCAP to 2 CAP, sympathetic activation is indicated by tachycardia and reduced respiratory arrhythmia in the heart rate signal. At the same time, we observed a marked link between EEG and HRV at the CAP frequency. During 2 CAP MC, the increased synchronization involved myoclonus and respiration. The underlying mechanism seems to be related to a global control system at the central level that involves the different systems.  相似文献   

19.
20.
In this paper, a new approach based on eigen-systems pseudo-spectral estimation methods, namely Eigenvector (EV) and MUSIC, and Multiple Layer Perceptron (MLP) neural network is introduced. In this approach, the calculated EEG (electroencephalogram) spectrum is divided into smaller frequency sub-bands. Then, a set of features, {maximum, entropy, average, standard deviation, mobility}, are extracted from these sub-bands. Next, incorporating a set of the EEG time domain features {standard deviation, complexity measure} with the spectral feature set, a feature vector is formed. The feature vector is then fetched into a MLP neural network to classify the signal into the following three states: normal (healthy), epileptic patient signal in a seizure-free interval (inter-ictal), and epileptic patient signal in a full seizure interval (ictal). The experimental results show that the classification of the EEG signals maybe achieved with approximately 97.5% accuracy and the variance of 0.095% using an available public EEG signals database. The results are among the best reported methods for classifying the three states aforementioned. This is a high speed with high accuracy as well as low misclassifying rate method so it can make the practical and real-time detection of this chronic disease feasible.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号