首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

The aim of this study was to dosimetrically compare three total body irradiation (TBI) techniques which can be delivered by a standard linear accelerator, and to deduce which one is preferable. Specifically, Extended Source to Surface Distance (SSD) Field-in-Field (FiF), Extended SSD Volumetric Modulated Arc Therapy (VMAT), and Standard SSD VMAT TBI techniques were dosimetrically evaluated. Percent depth dose and dose profile measurements were made under treatment conditions for each specified technique. After having generated treatment plans with a treatment planning system (TPS), dose homogeneity and critical organ doses were investigated on a Rando phantom using radiochromic films and optically stimulated luminescence dosimeters (OSLDs). TBI dose of 12 Gy in six fractions was prescribed for each technique. The gamma index (5%/5 mm) was used for the analysis of radiochromic films. Passing rates for Extended SSD FiF, Extended SSD VMAT and Standard SSD VMAT techniques were found to be 90%, 87% and 94%, respectively. OSLD measurements were within?±?5% agreement with TPS calculations for the first two techniques whereas the agreement was found to be within?±?3% for the Standard SSD VMAT technique. TPS calculations demonstrated that mean lung doses in the first two techniques were around 8.5 Gy while it was kept around 7 Gy in Standard SSD VMAT. It is concluded that Standard SSD VMAT is superior in sparing the lung tissue while all three TBI techniques are feasible in clinical practice with acceptable dose homogeneity. In the absence of VMAT-based treatment planning, Extended SSD FiF would be a reasonable choice compared to other conventional techniques.

  相似文献   

2.
Dosimetry in small radiation field is challenging and complicated because of dose volume averaging and beam perturbations in a detector. We evaluated the suitability of the “Edge-on” MOSkin (MOSFET) detector in small radiation field measurement. We also tested the feasibility for dosimetric verification in stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT). “Edge-on” MOSkin detector was calibrated and the reproducibility and linearity were determined. Lateral dose profiles and output factors were measured using the “Edge-on” MOSkin detector, ionization chamber, SRS diode and EBT2 film. Dosimetric verification was carried out on two SRS and five SRT plans. In dose profile measurements, the “Edge-on” MOSkin measurements concurred with EBT2 film measurements. It showed full width at half maximum of the dose profile with average difference of 0.11 mm and penumbral width with difference of ±0.2 mm for all SRS cones as compared to EBT2 film measurement. For output factor measurements, a 1.1% difference was observed between the “Edge-on” MOSkin detector and EBT2 film for 4 mm SRS cone. The “Edge-on” MOSkin detector provided reproducible measurements for dose verification in real-time. The measured doses concurred with the calculated dose for SRS (within 1%) and SRT (within 3%). A set of output correction factors for the “Edge-on” MOSkin detector for small radiation fields were derived from EBT2 film measurement and presented. This study showed that the “Edge-on” MOSkin detector is a suitable tool for dose verification in small radiation field.  相似文献   

3.
Measurements of natural radiation were carried out in cave dwellings distributed in the Chinese loess plateau. Those dwellings are located in Shanxi and Shaanxi provinces. Radon and thoron gas concentrations were measured using a passive integrating radon-thoron discriminative detector. Concentrations of thoron decay products were estimated from measurements of their deposition rates. A detector was placed at the center of each dwelling for 6 months and replaced with a fresh one for another 6 months. Measurements were conducted in 202 dwellings from August 2001 through August 2002. A short-term measurement was conducted during the observation period. In addition, gamma-ray dose rates were measured both indoors and outdoors with an electronic pocket dosimeter. Radioactivities in soil were determined by gamma-ray spectrometry with a pure germanium detector. Among 193 dwellings, indoor radon concentrations ranged from 19 to 195 Bq m(-3) with a geometric mean (GM) of 57 Bq m(-3), indoor thoron concentrations ranged from 10 to 865 Bq m(-3) with a GM of 153 Bq m(-3), and indoor equilibrium equivalent thoron concentrations ranged from 0.3 to 4.9 Bq m(-3) with a GM of 1.6 Bq m(-3). Arithmetic means of the gamma-ray dose rates were estimated to be 140 nGy h(-1) indoors and 110 nGy h(-1) outdoors. The present study revealed that the presence of thoron is not negligible for accurate radon measurements and thus that special attention should be paid to thoron and its decay products for dose assessment in such an environment. More systematic studies are necessary for a better understanding of thoron and its decay products.  相似文献   

4.
PurposeThere is little evidence in the literature which quantifies the accuracy of Treatment Planning Systems (TPSs) using large fields at extended SSD (eSSD). This paper introduces the approach taken at Christchurch Hospital, New Zealand to validate the use of the Monaco TPS for Total Body Irradiation (TBI) treatments.MethodsA purpose-built device for allowing precise movements of block-like phantoms called a Phantom Mobility Device (PMD) was used for collecting measurements at eSSD. These measurements were used for determining the ability of the Monaco TPS (originally validated for SSDs between 80 and 110 cm) to accurately model dose distributions for TBI treatments at Christchurch Hospital on either treatment machine one (T1) or two (T2) with SSD values of 341 and 432.6 and clinically useful field sizes of 120 and 170 cm, respectively.ResultsWe found that within the limits of measurement uncertainty the PMD contributed no determinable scatter to the measurements and proved a reliable approach for eSSD dose measurements. Additionally, by applying depth and off-axis distance constraints of use for TPS information it is possible to use the existing Monaco CCC model at eSSD for block phantom geometries. Dose Difference (DD) analysis showed a clinically acceptable agreement between the CCC model and measured data over a range of depths and off-axis distances.ConclusionsThe PMD was determined to be a useful tool for accurate measurement of extended SSD treatment fields. Monaco TPS CCC model agreed well for block phantoms so future comparisons to anthropomorphic phantoms or patient data are feasible.  相似文献   

5.
Purpose  We used total body irradiation (TBI) as conditioning for cord blood transplantation studies in pigtailed macaques. In these studies, different doses of TBI were explored to obtain optimal myelosuppression with acceptable radiation-related side effects.
Methods  Four macaques received TBI ranging from 800 to 1320 cGy, followed by standard post-transplant care. Hematopoietic recovery was monitored by CBC and donor contribution by variable number of tandem repeats analysis.
Results  Animals receiving 800 or 1020 cGy TBI tolerated the irradiation well with autologous recovery of neutrophils within 24 days. At a dose of 1200 cGy, neither autologous recovery nor extramedullary toxicity was observed. A fourth animal received 1320 cGy of TBI and suffered significant toxicity necessitating termination of the study.
Conclusions  We conclude that previously considered myeloablative doses of TBI allowed for autologous recovery in the pigtailed macaque, and that a dose of 1200 cGy may be most appropriate, providing both myeloablation and acceptable non-hematopoietic toxicities.  相似文献   

6.
Space radiation dosimetry measurements have been made on board the Space Shuttle. A newly developed active detector called "Real-time Radiation Monitoring Device (RRMD)" was used (Doke et al., 1995; Hayashi et al., 1995). The RRMD results indicate that low Linear Energy Transfer (LET) particles steadily penetrate around the South Atlantic Anomaly (SAA) without clear enhancement of dose equivalent and some daily periodic enhancements of dose equivalent due to high LET particles are seen at the lower geomagnetic cutoff regions (Doke et al., 1996). We also have been analyzing the space weather during the experiment, and found that the anomalous high-energy particle enhancement was linked to geomagnetic disturbance due to the high speed solar wind from a coronal hole. Additional analysis and other experiments are necessary for clarification of these phenomena. If a penetration of high-energy particles into the low altitude occurs by common geomagnetic disturbances, the prediction of geomagnetic activity becomes more important in the next Space Station's era.  相似文献   

7.
A major challenge in allogeneic bone marrow (BM) transplantation is overcoming engraftment resistance to avoid the clinical problem of graft rejection. Identifying gene pathways that regulate BM engraftment may reveal molecular targets for overcoming engraftment barriers. Previously, we developed a mouse model of BM transplantation that utilizes recipient conditioning with non-myeloablative total body irradiation (TBI). We defined TBI doses that lead to graft rejection, that conversely are permissive for engraftment, and mouse strain variation with regards to the permissive TBI dose. We now report gene expression analysis, using Agilent Mouse 8x60K microarrays, in spleens of mice conditioned with varied TBI doses for correlation to the expected engraftment phenotype. The spleens of mice given engrafting doses of TBI, compared with non-engrafting TBI doses, demonstrated substantially broader gene expression changes, significant at the multiple testing-corrected P <0.05 level and with fold change ≥2. Functional analysis revealed significant enrichment for a down-regulated canonical pathway involving B-cell development. Genes enriched in this pathway suggest that suppressing donor antigen processing and presentation may be pivotal effects conferred by TBI to enable engraftment. Regardless of TBI dose and recipient mouse strain, pervasive genomic changes related to inflammation was observed and reflected by significant enrichment for canonical pathways and association with upstream regulators. These gene expression changes suggest that macrophage and complement pathways may be targeted to overcome engraftment barriers. These exploratory results highlight gene pathways that may be important in mediating BM engraftment resistance.  相似文献   

8.
BackgroundThe dosimetric characterization of volumetric modulated arc therapy (VMAT)-based total-body irradiation (TBI) in pediatric patients is evaluated.Materials and methodsTwenty-two patients between the ages of 2 and 12 years were enrolled for VMAT-based TBI from 2018 to 2020. Three isocenters were irradiated over three overlapping arcs. While prescribing 90% of the TBI dose to the planning treatment volume (PTV), two fractions (2 Gy each) were delivered each day; hence 12 Gy was delivered in six fractions. During treatment optimization, the mean lung and kidney doses were set not to exceed 7 Gy and 7.5 Gy, respectively. The maximum lens dose was also set to less than 4 Gy. Patient quality assurance was carried out by comparing treatment planning system doses to the 3-dimensional measured doses by the ArcCHECK® detector. The electronic portal imaging device (EPID) gamma indices were also obtained.ResultsThe average mean lung dose was 7.75 ± 0.18 Gy, mean kidney dose 7.63 ± 0.26 Gy, maximum lens dose 4.41 ± 0.39 Gy, and the mean PTV dose 12.69 ± 0.16 Gy. The average PTV heterogeneity index was 1.15 ± 0.03. Average differences in mean kidney dose, mean lung dose, and mean target dose were 2.79% ± 0.88, 0.84% ± 0.45 and 0.93% ± 0.47, respectively; when comparing planned and ArcCHECK® measured doses. Only grade 1–2 radiation toxicities were recorded, based on CTCAE v5.0 scoring criteria.ConclusionsVMAT-TBI was characterized with good PTV coverage, homogeneous dose distribution, planned and measured dose agreement, and low toxicity.  相似文献   

9.

Aim

The aim of this study is to evaluate performance of ArcCHECK diode array detector for the volumetric modulated arc therapy (VMAT) patient specific quality assurance (QA). VMAT patient specific QA results were correlated with ion chamber measurement. Dose response of the ArcCHECK detector was studied.

Background

VMAT delivery technique improves the dose distribution. It is complex in nature and requires proper QA before its clinical implementation. ArcCHECK is a novel three dimensional dosimetry system.

Materials and methods

Twelve retrospective VMAT plans were calculated on ArcCHECK phantom. Point dose and dose map were measured simultaneously with ion chamber (IC-15) and ArcCHECK diode array detector, respectively. These measurements were compared with their respective TPS calculated values.

Results

The ion chamber measurements are in good agreement with TPS calculated doses. Mean difference between them is 0.50% with standard deviation of 0.51%. Concordance correlation coefficient (CCC) obtained for ion chamber measurements is 0.9996. These results demonstrate a strong correlation between the absolute dose predicted by our TPS and the measured dose. The CCC between ArcCHECK doses and TPS predictions on the CAX was found to be 0.9978. In gamma analysis of dose map, the mean passing rate was 98.53% for 3% dose difference and 3 mm distance to agreement.

Conclusions

The VMAT patient specific QA with an ion chamber and ArcCHECK phantom are consistent with the TPS calculated dose. Statistically good agreement was observed between ArcCHECK measured and TPS calculated. Hence, it can be used for routine VMAT QA.  相似文献   

10.
The dosimetric package used inside Biorack on board STS76, STS81 and STS84 comprises passive detector stacks built from plastic nuclear track detectors (PNTDs), thermoluminescence detectors (TLDs) and one or two active DOSTEL (DOSimetric TELescope) units using planar silicon detectors. Five passive detector stacks were exposed at different places inside the BIORACK incubators and in different stowage positions. DOSTEL units were exposed inside the 22 degrees C incubator in all flights. Mission integrated dose measurements, particle fluence rates and neutron doses are obtained from the passive detector stacks. These results are complemented by time resolved particle counts and dose rates and linear energy transfer (LET) spectra separately for the contribution of the trapped particles and the galactic cosmic rays (GCR) as a result of the DOSTEL measurements. In addition, it was possible to investigate the anisotropy of the radiation field inside Biorack by the use of a second DOSTEL unit on STS84. Since all exposures are during a solar minimum period, the total radiation exposure is of a similar extent for all flights, although position differences in dose rate up to a factor of two are observed. Particle fluence rates show lower variations. Mission averaged mean quality factors (Q) determined from the LET spectra are 2.0+/-0.1; the deduced dose equivalent rates range from 631 to 716 microSv/day.  相似文献   

11.
Seven detector packages consisting of plastic nuclear track detectors, nuclear emulsions and thermoluminescence dosimeters were exposed in different locations inside BIORACK during the IML2 mission. The detectors supplement each other in their registration characteristics and cover well the different contributions of the space radiations to the dose. In this report, results are given on total dose measurements, cosmic ray flux and neutron dose. Total doses differ by up to a factor of 1.5 and heavy ion fluxes by more than a factor of 6 in the different locations. The results are compared with those of previous missions. The mission equivalent dose for the astronauts was calculated from the measurements to be 3.8 mSv.  相似文献   

12.
The use of isotope dilution analysis (IDA) with inductively coupled plasma-mass spectrometry (ICP-MS) for the determination of oxidized metallothionein (MT) by a Cd-saturation method is investigated. The method developed here is a modification of an earlier methodology which used a radioactive Cd isotope ((109)Cd). While retaining the many advantages of this previous approach, the procedure presented here uses stable isotope ratio measurements ((114)Cd/(111)Cd) for the determination of MT. Experimental parameters governing the instrumental precision and accuracy for isotope ratio measurements of Cd by ICP-MS were characterized. Systematic errors, including mass bias, detector dead time, and spectroscopic interferences, could be easily corrected. The isotope dilution ICP-MS method was validated by the determination of very low levels of cadmium in biological certified reference materials (NIST SRM 2670 freeze-dried urine, IAEA H-8 horse kidney, and BCR TP-25 lichens). Finally, the IDA procedure was evaluated for the determination of oxidized MT by a Cd-saturation method previously developed using radioactive (109)Cd. The final procedure was applied to the quantification of MT in Long-Evans Cinnamon rat liver cytosol samples and the results were compared with data obtained for the same samples using the reference (109)Cd methodology. A good agreement between the analytical values obtained by both methods was observed.  相似文献   

13.
PurposeIn modern radiotherapy techniques, to ensure an accurate beam modeling process, dosimeters with high accuracy and spatial resolution are required. Therefore, this work aims to propose a simple, robust, and a small-scale fiber-integrated X-ray inorganic detector and investigate the dosimetric characteristics used in radiotherapy.MethodsThe detector is based on red-emitting silver-activated zinc-cadmium sulfide (Zn,Cd)S:Ag nanoclusters and the proposed system has been tested under 6 MV photons with standard dose rate used in the patient treatment protocol. The article presents the performances of the detector in terms of dose linearity, repeatability, reproducibility, percentage depth dose distribution, and field output factor. A comparative study is shown using a microdiamond dosimeter and considering data from recent literature.ResultsWe accurately measured a small field beam profile of 0.5 × 0.5 cm2 at a spatial resolution of 100 µm using a LINAC system. The dose linearity at 400 MU/min has shown less than 0.53% and 1.10% deviations from perfect linearity for the regular and smallest field. Percentage depth dose measurement agrees with microdiamond measurements within 1.30% and 2.94%, respectively for regular to small field beams. Besides, the stem effect analysis shows a negligible contribution in the measurements for fields smaller than 3x3 cm2. This study highlights the drastic decrease of the convolution effect using a point-like detector, especially in small dimension beam characterization. Field output factor has shown a good agreement while comparing it with the microdiamond dosimeter.ConclusionAll the results presented here anticipated that the developed detector can accurately measure delivered dose to the region of interest, claim accurate depth dose distribution hence it can be a suitable candidate for beam characterization and quality assurance of LINAC system.  相似文献   

14.
A method for the determination of organotin compounds in urine samples based on liquid–liquid extraction (LLE) in hexane and gas chromatographic separation was developed and optimized. Seven organotin species, namely monobutyltin (MBT), dibutyltin (DBT), tributyltin (TBT), tetrabutyltin (TeBT), monophenyltin (MPhT), diphenyltin (DPhT) and triphenyltin (TPhT), were in situ derivatized by sodium tetraethylborate (NaBEt4) to form ethylated less polar derivatives directly in the urine matrix. The critical parameters which have a significant effect on the yield of the successive liquid–liquid extraction procedure were examined, by using standard solutions of tetrabutyltin in hexane. The method was optimized for use in direct analysis of undiluted human urine samples and ways to overcome practical problems such as foam formation during extraction, due to various constituents of urine are discussed. After thorough optimization of the extraction procedure, all examined species could be determined after 3 min of simultaneous derivatization and extraction at room temperature and 5 min phase separation by centrifugation. Gas chromatography with a microwave-induced plasma atomic emission detector (MIP-AED) as element specific detector was employed for quantitative measurements, while a quadrupole mass spectrometric detector (MS) was used as molecular specific detector. The detection limits were between 0.42 and 0.67 μg L?1 (as Sn) for the quantitative LLE–GC–MIP-AED method and the precision between 4.2% and 11.7%, respectively.  相似文献   

15.
rac-Methadone is used clinically for the chronic maintenance treatment of heroin addiction and for the relief of pain. As the pharmacological activity of methadone is due primarily to the (-)-(R)-enantiomer, stereospecific measurements of methadone serum concentrations in methadone-treated patients are expected to be more relevant for clinical studies than earlier described total drug measurements. This study describes a stereospecific gas chromatographic (GC) method for the determination of methadone in serum. The extracted methadone was derivatizised with (-)-menthyl chloroformate. The diastereometric derivatives were analysed by GC on a capillary column and detected with a nitrogen-phosphorus detector. The resolution factor obtained for the methadone enantiomers was 1.1 with a relatively short time of analysis (30 min). By analysing the pure (-)-(R)-enantiomer, no racemization was seen during the analysis. The lower limit of quantitation was 75 nmol/l for each enantiomer. Measurements of the ratio between (-)-(R)- and (+)-(S)-methadone concentrations in serum from five methadone-treated patients showed interindividual differences (range 0.5-1.1). The patient results correlated well with those from another GC method measuring total methadone.  相似文献   

16.
BACKGROUND AND PURPOSE: Total body irradiation (TBI) is a routine preconditioning procedure for the treatment of leukemia and aplastic anemia, prior to bone marrow transplantation (BMT). Ionizing radiation generates reactive oxygen derived species (ROS) that can be removed by antioxidants. Our purpose is to determine the antioxidant status of patients undergoing TBI by evaluating the oxidant stress and their antioxidant capacity. MATERIAL AND METHODS: We evaluated by cyclic voltammetry (CV) the total antioxidant capacity (TAC) in plasma of 14 patients undergoing TBI prior to BMT. The levels of the antioxidants, ascorbic acid (AA) and uric acid (UA) were determined by HPLC-ECD. The oxidant stress level was calculated by the ratio [dehydro ascorbic acid]/total ascorbic acid]. RESULTS: TAC was reduced by 36% (p < 0.02) but after 4 months recovered to a level 22% higher than before the treatment (p < 0.05). Both, AA and UA, decreased following irradiation by 84% (p < 0.02) and 24% (p < 0.05) respectively, but returned to a level of 21% and 320% after 4 months compared to baseline values. The changes in [UA] were affected by Allopurinol (xanthine oxidase inhibitor), given as a routine pretransplant therapy until day -1. The [dehydroascorcbic acid]/[total ascorbic acid] (%) was 45% (range of normal controls = 13.2 +/- 1.5%) and increased by 69% following TBI. In order to obtain a decrease in the TAC of plasma in vitro, comparable to that in vivo, a 1000 fold higher dose of irradiation was required. CONCLUSIONS: TBI caused a pronounced decrease in antioxidant capacity and an excessive increase in oxidant stress. We assume that TBI alters antioxidant homeostasis greatly enhancing the stress damage. CV measurements may lead to a better understanding of the balance between oxidant stress and antioxidant utilization, and to a reconsideration of the routine use of Allopurinol as pretreatment for TBI, and antioxidant support before and/or after TBI.  相似文献   

17.
Liu  Huan  He  Shiqing  Wang  Jianpeng  Li  Chong  Liao  Yongshi  Zou  Qin  Chen  Rui 《Neurochemical research》2022,47(6):1574-1587

Traumatic brain injury (TBI) is the leading cause of death and disability in trauma patients. However, the effects and mechanism of autophagy after TBI remain unclear. This study aimed to investigate whether tetrandrine could ameliorate TBI through autophagy to reduce ferroptosis. A mice model for TBI was implemented. Behavioral and histomorphological experiments were performed to evaluate outcomes of the mice. The ferroptosis levels was detected by Perls staining. Enzyme-linked immunosorbent assay (ELISA) was applied to detect malondialdehyde (MDA), glutathione (GSH), and glutathione peroxidase 4 (GPX4) levels in the brain tissue. Western blot test was performed to detect Beclin 1, light chain 3 (LC3) II/I, p62, GPX4, SCL7A11, and ferritin heavy chain 1 (FTH1) levels, and the expression of LC3B, Beclin 1, GPX4, and FTH1 in the brain tissue was detected by immunofluorescence (IF). The behavioral and histomorphological results demonstrated that tetrandrine improved the neurological function and cerebral edema on days 1, 3, and 7 after TBI. The ELISA results suggested that tetrandrine reduced the MDA concentration and increased GSH concentration on days 1, 3, and 7 after TBI. IF staining and Perls staining reflected that tetrandrine promoted autophagy and inhibited ferroptosis on days 1, 3, and 7 after TBI, respectively. Tetrandrine further improved the neurological function, cerebral edema, autophagy, and ferroptosis on days 1, 3, and 7 after TBI after adding the autophagy inducer rapamycin. The effect of TET in alleviating TBI increased with the increase of time and dose. Tetrandrine ameliorated TBI by regulating autophagy to reduce ferroptosis, providing a new therapeutic strategy for TBI.

  相似文献   

18.
AimTo evaluate if a radiochromic film (RF) Gafchromic EBT3 is suitable for surface dose measurements of radiotherapy treatments performed with a 6 MV linear accelerator. Two aspects of RF were analyzed, beam energy dependence and surface dose determination.BackgroundThe measurements done at the surface or near the radiation source are done without charged electronic equilibrium and also have contribution of electron contamination. The detectors used for these measurements should not alter the dose to the target. To counteract these dosimetric problems it is proposed to do the measurements with radiochromic films which are thin detectors and have tissue equivalent properties.Materials and MethodsThe measurements were done using a Novalis linear accelerator (LINAC) with nominal energy of 6 MV. To determine the surface dose, the total scatter factors (TSF) of three different field sizes were measured in a water phantom at 5 cm depth. Energy dependence of EBT3 was studied at three different depths, using a solid water phantom. The surface measurements were done with the RF for the same field sizes of the TSF measurements. The value of the percentage depth dose was calculated normalizing the doses measured in the RF with the LINAC output, at 5 cm depth, and the TSF.ResultsThe radiochromic films showed almost energy independence, the differences between the curves are 1.7% and 1.8% for the 1.5 cm and 10 cm depth, respectively. The percentage depth doses values at the surface measured for the 10 cm × 10 cm, 5 cm × 5 cm and 1 cm × 1 cm were 26.1 ± 1.3%, 21.3 ± 2.4% and 20.2 ± 2.6%, respectively.ConclusionsThe RF-EBT3 seems to be a detector suitable for measurements of the dose at the surface. This suggests that RF-EBT3 films might be good candidates as detectors for in vivo dosimetry.  相似文献   

19.
BackgroundTo analyze and compare dose distribution homogeneity in selected points (especially in the chest wall region) for patients irradiated with two different TBI techniques to achieve a uniform total dose (excluding lungs area) specified in the range of 11.4–14.0 Gy.Material and methodsFrom August 2000 to December 2009, a group of 158 patients was treated by the use of 15 MV photon irradiation consisting of six fractions: four opposed lateral and two anterior–posterior/posterior–anterior (AP/PA). Patients were irradiated with the fraction dose of 2 Gy twice a day for 3 consecutive days. The prescribed dose to PC point (specified at intersection of the beam axis with the mid-plane of the patient irradiated laterally) was 12 Gy. Since January 2010 until closing the study, another group of 50 patients was treated according to a modified protocol. The treatment was carried out in six lateral fractions only, twice a day, for three following days and a lateral lung shield was used for a part of total irradiation time. The measurements of doses in 20 selected points of patient's body were carried out by means of MOSFET detectors.ResultsThe modified TBI technique allows to achieve an expected homogenous dose in the points of interest similar to that obtained by using the initial protocol. The calculated and measured in vivo doses met the specified range of 11.4–14 Gy for both applied TBI protocols.ConclusionsOur results indicate that for all patients the homogenous dose distribution in the specified range was achieved.  相似文献   

20.
K-ras gene patterns of PCR products in response to total body irradiation (TBI) in mice fed four kinds of diets were assessed. Male mice were fed a 1% protein diet, 7% protein diet, 20% protein diet, or a 60% protein diet for 4 weeks, received TBI at a dose of 0, 2, or 6 Gy, and were sacrificed 4 weeks post-TBI. Severe DNA damage in mice fed a 1% protein diet with a high dose of radiation exposure (TBI at 6 Gy) was observed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号