首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A quartz crystal biosensor for measurement in liquids.   总被引:5,自引:0,他引:5  
The detection of anti-human immunodeficiency virus (HIV) antibodies by means of synthetic HIV peptide immobilized on a piezoelectric quartz sensor is demonstrated. The measurement set-up consists of an oscillator circuit, a suitably modified AT-cut thickness-shear-mode quartz crystal with gold electrodes, which is housed in a special reaction vessel, and a computer-controlled frequency counter for the registration of the measured frequency values. The quartz crystal is adapted for a steady operation in liquids at a frequency of 20 MHz. In phosphate-buffered saline solution the oscillator reaches a stability of about 0.5 Hz within a few seconds, of about 2 Hz within 10 min and about 30 Hz within 1 h. The frequency shift due to the adsorption of various proteins to the uncoated sensor surface has been investigated. It can be shown that a stable adsorptive binding of proteins to an oscillating gold surface is feasible and can be used for the immobilization of a receptor layer (e.g. HIV peptide). Specific binding of the anti-HIV monoclonal antibody to the HIV peptide immobilized on the quartz sensor is demonstrated. Control experiments show, however, additional unspecific binding. According to the experiments, the Sauerbrey formula gives a sufficiently accurate value for the decrease of the resonant frequency due to adsorption or binding of macromolecular proteins on the quartz crystal surface.  相似文献   

2.
The fundamental nature of impact testing requires a cautious approach to signal processing, to minimize noise while preserving important signal information. However, few recommendations exist regarding the most suitable filter frequency cut-offs to achieve these goals. Therefore, the purpose of this investigation is twofold: to illustrate how residual analysis can be utilized to quantify optimal system-specific filter cut-off frequencies for force, moment, and acceleration data resulting from in-vitro upper extremity impacts, and to show how optimal cut-off frequencies can vary based on impact condition intensity. Eight human cadaver radii specimens were impacted with a pneumatic impact testing device at impact energies that increased from 20J, in 10J increments, until fracture occurred. The optimal filter cut-off frequency for pre-fracture and fracture trials was determined with a residual analysis performed on all force and acceleration waveforms. Force and acceleration data were filtered with a dual pass, 4th order Butterworth filter at each of 14 different cut-off values ranging from 60Hz to 1500Hz. Mean (SD) pre-fracture and fracture optimal cut-off frequencies for the force variables were 605.8 (82.7)Hz and 513.9 (79.5)Hz, respectively. Differences in the optimal cut-off frequency were also found between signals (e.g. Fx (medial-lateral), Fy (superior-inferior), Fz (anterior-posterior)) within the same test. These optimal cut-off frequencies do not universally agree with the recommendations of filtering all upper extremity impact data using a cut-off frequency of 600Hz. This highlights the importance of quantifying the filter frequency cut-offs specific to the instrumentation and experimental set-up. Improper digital filtering may lead to erroneous results and a lack of standardized approaches makes it difficult to compare findings of in-vitro dynamic testing between laboratories.  相似文献   

3.
BACKGROUND AND PURPOSE: This study aims to verify if amplitude and spectral characteristics of surface EMG signal are modified due to recording in a wet environment. METHODS: Isometric contractions of the biceps brachii muscle of ten subjects were performed in several different set-up combinations, both in dry (D) and in water from hydrotherapy pools (PW), with (PWM) or without moving the pool water and with (T) or without water-resistant adhesive taping. RESULTS: In PW condition the amplitude of the recorded signal is reduced to 5-10% of the corresponding signal recorded in D condition. In PWM the power spectrum is drastically reduced and altered by the water movement that introduces an increase of spectral power in the frequency range 0-20 Hz. The use of T modality allows to record signals with both amplitude and spectral frequencies comparable with those obtained in the D conditions. DISCUSSION AND CONCLUSION: This work demonstrates the need for water resistant taping when EMG signals are recorded in water. Signals recorded without such a protective film are strongly affected in their amplitude and frequency characteristics by the conductivity and the movement of water.  相似文献   

4.
DNA functionalised semiconductor metallic oxide electrodes have been developed for the direct electrochemical detection of DNA hybridization, without labelling or the introduction of a redox couple. Conductive CdIn(2)O(4) thin films with controlled properties were deposited on glass substrates using an aerosol pyrolysis technique. The films exhibit a polycrystalline microstructure with a surface roughness of 1.5 nm (r.m.s.) and an electrical resistivity ranging between 1 and 3 x 10(-3) Omega cm. These electrodes were functionalised using hydroxylation and silanisation steps, to allow the binding of DNA probe sequences (20 bases). The electrical detection of DNA hybridization with complementary sequences has been performed using electrochemical impedance spectrometry (EIS) measuring the variation of impedance before and after hybridization. Two set-ups were used, a standard set-up including three electrodes and a set-up including two symmetrical electrodes. In both configurations, a significant increase of the impedance modulus, more particularly of the real part of the impedance (160-225% according to the electrochemical cell used) has been obtained over a frequency range of 10-10(5)Hz. DNA hybridization has also been systematically confirmed using the fluorescence spectrometry. This study emphasizes the high sensitivity of the CdIn(2)O(4) as a working electrode for the detection of biological events occurring at the electrode surface.  相似文献   

5.
Evoked responses in CA3 area to the mossy fibers stimulation were studied after low and high frequency tetanizations of the perforant path. Stimulations of perforant path with 10 and 100 Hz frequencies inducted depression testing through the same path. Subthreshold for potentiation of the mossy fibers inputs to the CA3 tetanization of the perforant path with 10 Hz frequency transformed to threshold one after previous tetanization of the perforant path with 100 Hz frequency. Tetanization of the mossy inputs to the CA3 with 10 Hz frequency leaded to potentiation whereas tetanization with frequency 100 Hz depressed the same inputs. High frequency tetanizations (100 Hz) of the perforant path with theta-rithm frequency stimulation basically depressed of the CA3 evoked responces to the mossy fiber stimulation.  相似文献   

6.
This paper presents the results of a preliminary study on the effects of sinusoidal magnetic fields on the growth and degradation potential of Flavobacterium species in paper mill effluents. The paper presents a brief account of the experimental set-up, protocol and the essential parameters employed. The study was carried out using a pure colony of Flavobacterium species and subjecting them to Sinusoidal Magnetic Fields (SMF) at different frequencies, intensities and duration of exposure in order to obtain the “frequency window” of optimum response. The organisms were subjected to 1 Hz (100 nT, 1500 nT and 4000 nT) for 5 hours per day for 3, 6, 9, 12, 15, 18 and 20 days and to 10 Hz (100 nT, 1500 nT and 4000 nT) for 5 hours per days for 3, 6, 9, 12, 15, 18 and 20 days. The organism has been primarily analyzed for its efficacy in the treatment of paper mill effluent by using a sinusoidal magnetic field. The growth kinetics of the bacterium with the application of sinusoidal magnetic fields was studied. As judged from the physico-chemical properties of the effluent, Flavobacterium species was found to have a four fold increase with respect to growth when exposed to SMF of 10 Hz, 100 nT for 30 hrs (5 hours per day for 6 days). The BOD, COD, lignin, phenol and protein content were found reduced in the effluent using SMF treated cells.

Pre-treatment of Flavobacterium species with Sinusoidal Magnetic Fields (SMF) appears to result in more effective degradation of the paper mill effluents.  相似文献   

7.
Four squirrel monkeys (Saimiri sciureus) were tested for their frequency discrimination capacity using an eyeblink classical conditioning procedure, with air puff against the eye as unconditioned stimulus and 600-ms pure tones as conditioned stimuli. Absolute frequency difference thresholds showed a minimum (20-41 Hz, mean 30 Hz) at 4,000-8,000 Hz and increased towards higher as well as lower frequencies (70-90 Hz, mean 80 Hz at 300 Hz; 44-120 Hz, mean 82 Hz at 16,000 Hz). Relative frequency difference thresholds increased from higher to lower frequencies, with values as low as 0.3-0.8% (mean 0.5%) at 16,000 Hz and as large as 24-30% (mean 27%) at 300 Hz. The squirrel monkey's frequency discrimination function thus shows a severe deviation from Weber's law. The frequency difference thresholds are comparable to human's in the 4,000-8,000 Hz range, but are 65-80 times higher in the 500- to 300-Hz range. Individuals with high auditory thresholds do not necessarily also have high frequency difference thresholds.  相似文献   

8.
Ledberg A  Robbe D 《PloS one》2011,6(11):e27575
The hippocampal theta rhythm is required for accurate navigation and spatial memory but its relation to the dynamics of locomotion is poorly understood. We used miniature accelerometers to quantify with high temporal and spatial resolution the oscillatory movements associated with running in rats. Simultaneously, we recorded local field potentials in the CA1 area of the hippocampus. We report that when rats run their heads display prominent vertical oscillations with frequencies in the same range as the hippocampal theta rhythm (i.e., 6-12 Hz). In our behavioral set-up, rats run mainly with speeds between 50 and 100 cm/s. In this range of speeds, both the amplitude and frequency of the "theta" head oscillations were increasing functions of running speed, demonstrating that the head oscillations are part of the locomotion dynamics. We found evidence that these rhythmical locomotor dynamics interact with the neuronal activity in the hippocampus. The amplitude of the hippocampal theta rhythm depended on the relative phase shift with the head oscillations, being maximal when the two signals were in phase. Despite similarity in frequency, the head movements and LFP oscillations only displayed weak phase and frequency locking. Our results are consistent with that neurons in the CA1 region receive inputs that are phase locked to the head acceleration signal and that these inputs are integrated with the ongoing theta rhythm.  相似文献   

9.
A set-up for percutaneous electrical stimulation of the forearm extensor muscles and measurement of wrist extension force is described. The frequency-force relationship and pulse duration-force relationship are described together with an experimental protocol showing that brief electrical test stimulations do not produce fatigue. In another set of experiments carried out a few weeks later, the subjects performed handgrip contractions: protocol A at 25% of maximal voluntary contraction (MVC) continuously until exhaustion, protocol B at 25% MVC intermittent (contraction + relaxation = 10 + 2 s) until exhaustion, and protocol C at 25% MVC intermittent until half the time to exhaustion. In all experiments, brief electrical stimulations were used to test the degree of fatigue during and up to 24 h after the experiments. There were marked changes in the force during stimulation at 20 and 100 Hz and these changes did not correlate with the increase in intramuscular temperature. Low frequency fatigue persisted for at least 24 h after protocol A and 1 h after protocols B and C. The significance of this is discussed and it is suggested that low frequency fatigue could be used as a sensitive indicator of muscle dysfunction after low and medium intensity exercise.  相似文献   

10.
Simultaneous stimulation of the parasympathetic and sympathetic nerves to the parotid gland of rats elicited saliva at a rate dependent on the frequency of sympathetic stimulation when parasympathetic frequency was maintained at 16 Hz. The flow rate was lowest at 2 Hz (sympathetic), moderate at 5 Hz, and highest at 16 Hz. Cl concentration of the saliva evoked with stimulation of both nerves was highest at the highest frequency and flow rate (maintained at the level of 102 mEq/liter, for 35 min) and lowest at 2 Hz (declining from 40 mEq/liter initially to 28 mEq/liter). With sympathetic nerve stimulation alone, Cl concentration ranged from 27 to 58 mEq/liter when frequency was varied from 2 to 16 Hz, and with parasympathetic stimulation alone (16 Hz), it ranged from 132 to 124 mEq/liter. Amylase concentration of sympathetically elicited saliva was, in contrast, highest at 2 Hz (1.5 times the level at 5 Hz, and twice the level at 16 Hz), and nearly 18-38 times that seen with parasympathetic stimulation alone. The same pattern was found when both nerves were stimulated, and at 2 Hz (sympathetic), amylase concentration was 1.6 times the level at 5 Hz and 2.6 times the level at 16 Hz. When the two nerves were simultaneously stimulated, the total amount of amylase secreted over 35 min was twice as high as that observed with sympathetic nerve stimulation alone, at any frequency. The relation of frequency to norepinephrine concentration was examined. There was no consistent difference in norepinephrine concentration related to variation in frequency of sympathetic stimulation. Only when both nerves were stimulated at 16 Hz was there a statistically significant reduction in norepinephrine concentration of 46%. A relation between frequency of sympathetic stimulation, flow rate, amylase concentration, and Cl concentration was established, but these changes could not be directly correlated with quantitative differences in norepinephrine concentration.  相似文献   

11.
Skull fracture is a frequently observed type of severe head injury. Historically, a variety of impact test set-ups and techniques have been used for investigating skull fracture. The most frequently used are the free-fall technique, the guided fall or drop tower set-up and the piston-driven impactor set-up. This document proposes a new type of set-up for cadaver head impact testing which combines the strengths of the most frequently used techniques and devices. The set-up consists of two pendulums, which allow for a 1 degree of freedom rotational motion. The first pendulum is the impactor and is used to strike the blow. The head is attached to the second pendulum using a polyester resin. Local skull deformation and impact force are measured with a sample frequency of 65 kHz. From these data, absorbed energy until skull fracture is calculated. A set-up evaluation consisting of 14 frontal skull and head impact tests shows an accurate measurement of both force and local skull deformation until fracture of the skull. Simplified mechanical models are used to analyse the different impacting techniques from literature as well as the new proposed set-up. It is concluded that the proposed test set-up is able to accurately calculate the energy absorbed by the skull until fracture with an uncertainty interval of 10%. Second, it is concluded that skull fracture caused by blunt impact occurs before any significant motion of the head. The two-pendulum set-up is the first head impact device to allow a well-controlled measurement environment without altering the skull stress distribution.  相似文献   

12.
前期研究发现,50 Hz弱磁场辐照能明显降低细胞的微丝含量和组装效率,对actin骨架形态也有明显影响.电磁生物学效应是否与辐照场频率相关,一直受到研究者的关注.单体球状肌动蛋白(G-actin)是带电结构,电磁场频率会影响其振荡频率并对微丝聚合效率产生影响.本文从细胞骨架形态和蛋白质两层次,采用免疫荧光技术考察0.4 m T,在35~140 Hz范围内5个频率的极低频磁场(ELF-MF)对FL细胞中纤维状肌动蛋白(F-actin)含量的影响,并采用荧光共振能量转移技术(FRET)验证效应最明显的频率对离体G-actin组装效率的干扰程度.结果显示,相比假辐照组,细胞中F-actin含量在50 Hz辐照组下降了(34.66±3.14)%,110 Hz次之,而另外3组(35、70和140 Hz)无显著性差异.同时利用FRET方法验证,在50 Hz磁场辐照下,离体环境中G-actin组装成F-actin的效率较假辐照组、35和70 Hz组显著降低.经初步分析,G-actin在弱ELF-MF中受到以洛伦兹力和感生电场力的合力为主的相关电磁力干扰,致使组装效率下降,且由于工频磁场周期与微丝组装周期的特殊相干性,在50 Hz频率附近可能存在一个外磁场干扰actin骨架组装的频率窗口.  相似文献   

13.
Biodegradable hydrogels are attractive 3D environments for cell and tissue growth. In cartilage tissue engineering, mechanical stimulation has been shown to be an important regulator in promoting cartilage development. However, the impact of mechanical loading on the gel degradation kinetics has not been studied. In this study, we examined hydrolytically labile gels synthesized from poly(lactic acid)-b-poly(ethylene glycol)-b-poly-(lactic acid) dimethacrylate macromers, which have been used for cartilage tissue engineering. The gels were subject to physiological loading conditions in order to examine the effects of loading on hydrogel degradation. Initially, hydrogels were formed with two different cross-linking densities and subject to a dynamic compressive strain of 15% at 0.3, 1, or 3 Hz. Degradation behavior was assessed by mass loss, equilibrium swelling and compressive modulus as a function of degradation time. From equilibrium swelling, the pseudo-first-order reaction rate constants were determined as an indication of degradation kinetics. The application of dynamic loading significantly enhanced the degradation time for the low cross-linked gels (P < 0.01) while frequency showed no statistical differences in degradation rates or bulk erosion profiles. In the higher cross-linked gels, a 3 Hz dynamic strain significantly increased the degradation kinetics resulting in an overall faster degradation time by 6 days compared to gels subject to the 0.3 and 1 Hz loads (P < 0.0001). The bioreactor set-up also influenced overall degradation behavior where the use of impermeable versus permeable platens resulted in significantly lower degradation rate constants for both cross-linked gels (P < 0.001). The compressive modulus exponentially decreased with degradation time under dynamic loading. Together, our findings indicate that both loading regime and the bioreactor setup influence degradation and should be considered when designing and tuning a biodegradable hydrogel where mechanical stimulation is employed.  相似文献   

14.
稳态白噪声对豚鼠听觉脑干诱发反应(ABR)功率谱的影响   总被引:1,自引:0,他引:1  
本文对豚鼠125和131dBSPL稳态白噪声暴露后听觉脑干诱发反应(ABR)功率谱进行了研究.研究结果表明:125dBSPL噪声暴露组0—200、210—500Hz频段谱能量比对照组相应频段谱能量增多(P<0.05),而510—900Hz频段谱能量却显著下降(P<0.01);131dBSPL噪声暴露组0-200Hz频段谱能量显著下降(P<0.01),但210-500Hz、910-1400Hz频段谱能量却明显增多(P<0.01).  相似文献   

15.
蝉的变音调复合声和发声机制的分析   总被引:3,自引:1,他引:2  
蒋锦昌  徐慕玲 《昆虫学报》1991,34(2):159-165
蛙鸣蝉(Meimuna opalifera (Walk).ab.punctata Kato)的自然鸣声为“ji…guái”的重复单变调复合声.“ji”为主音频约4800Hz的准单音;“guái”的波形和主音频呈明显的演变,优势主频约2100Hz和2800Hz的变音调声.鸟鸣蝉(Meimuna opalifera (Walk)var.formosana Kato)的自然鸣声由重复的“jiū…ruǎ”和“jiū…gū…”合成的双变调复合声.“jiū”为基频和主频分别约625Hz和2100—2300Hz的准单音;“ruǎ”的波形和主音频呈明显的演变,基音和优势主频分别约575—625Hz和1550—1750Hz的变音调声.“gū”为优势主频约625Hz的准单音.变音调复合声不仅与腹部运动有关,而主要取决于发声肌的收缩特性和发声膜肋结构的振动特性.  相似文献   

16.
Multi-electrode array recordings of spike and local field potential (LFP) activity were made from primary auditory cortex of 12 normal hearing, ketamine-anesthetized cats. We evaluated 259 spectro-temporal receptive fields (STRFs) and 492 frequency-tuning curves (FTCs) based on LFPs and spikes simultaneously recorded on the same electrode. We compared their characteristic frequency (CF) gradients and their cross-correlation distances. The CF gradient for spike-based FTCs was about twice that for 2-40 Hz-filtered LFP-based FTCs, indicating greatly reduced frequency selectivity for LFPs. We also present comparisons for LFPs band-pass filtered between 4-8 Hz, 8-16 Hz and 16-40 Hz, with spike-based STRFs, on the basis of their marginal frequency distributions. We find on average a significantly larger correlation between the spike based marginal frequency distributions and those based on the 16-40 Hz filtered LFP, compared to those based on the 4-8 Hz, 8-16 Hz and 2-40 Hz filtered LFP. This suggests greater frequency specificity for the 16-40 Hz LFPs compared to those of lower frequency content. For spontaneous LFP and spike activity we evaluated 1373 pair correlations for pairs with >200 spikes in 900 s per electrode. Peak correlation-coefficient space constants were similar for the 2-40 Hz filtered LFP (5.5 mm) and the 16-40 Hz LFP (7.4 mm), whereas for spike-pair correlations it was about half that, at 3.2 mm. Comparing spike-pairs with 2-40 Hz (and 16-40 Hz) LFP-pair correlations showed that about 16% (9%) of the variance in the spike-pair correlations could be explained from LFP-pair correlations recorded on the same electrodes within the same electrode array. This larger correlation distance combined with the reduced CF gradient and much broader frequency selectivity suggests that LFPs are not a substitute for spike activity in primary auditory cortex.  相似文献   

17.
Perivascular stimulation of the hepatic nerves in the in situ perfused rat liver with a constant frequency of 20 Hz over a constant period of 5 min had previously been shown to cause an increase of glucose output, a shift from lactate uptake to release, a reduction in perfusion flow (Hartmann et al. (1982) Eur. J. Biochem. 123, 521-526) and an overflow of noradrenaline into the hepatic vein (Beckh et al. (1982) FEBS Lett. 149, 261-265). In the present study the dependence of the metabolic and hemodynamic effects on the frequency between 1 and 30 Hz and duration of stimulation between 0.5 and 5 min was investigated. Over a constant stimulation period of 5 min the alteration in glucose exchange was maximal with a frequency of 10 Hz and half-maximal with 4 Hz. The corresponding values for the exchange of lactate were 5 Hz and 2 Hz, respectively, and for the perfusion flow 2.5 Hz and 1.5 Hz, respectively. An increase of noradrenaline overflow was not observed with the lower frequencies of 1 and 2.5 Hz; it was maximal at 10 Hz and half-maximal at 6.5 Hz. At a constant frequency of 20 Hz the increase in glucose release was maximal with a total stimulation period of 1 min and half-maximal with a period of 0.4 min. An essentially maximal alteration of lactate exchange and perfusion flow as well as of noradrenaline overflow was also effected by a stimulation period of 1 min.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

18.
In many species, females often prefer male signals that are more complex than in nature or beyond the range of calls naturally produced by conspecific males in spectral, temporal and amplitude features. In this study we examined both the ability of females to recognize signals outside the normal range of spectral frequency variation seen in male advertisement calls, and the influence of increasing call complexity by adding spectral components to enhance the attractiveness of a male advertisement call in the cricket frog Acris crepitans blanchardi, while keeping its amplitude constant. We used two different natural male call groups and created the following synthetic call groups: with a dominant frequency at 3500 Hz, i.e. at the normal dominant frequency with a frequency band within the sensitivity range of the inner ear basilar papilla; with a dominant frequency at 700 Hz, i.e. outside the normal range of variation and with a frequency band outside the sensitivity range of the basilar papilla but within the range of the amphibian papilla; with two dominant frequencies, one at 700 Hz and another at 3500 Hz, stimulating the basilar and amphibian papilla simultaneously. In double choice experiments we tested all combinations of the three call groups, and we tested the 3500 Hz call groups against the same natural call groups. Additionally, we tested the 700 Hz call groups against white noise to see whether these signals are meaningful in mate choice. Females preferred 3500 Hz call groups over all other call groups. The synthetic call group was as attractive to females as the same natural call group. The 700 Hz call group was not meaningful in mate choice. The combined (700 Hz + 3500 Hz) call group was significantly less attractive to females than the 3500 Hz call group. Thus, making a call more spectrally complex without increasing its overall amplitude decreases its attractiveness to cricket frog females.  相似文献   

19.
R S Cheng  B Pomeranz 《Life sciences》1979,25(23):1957-1962
This present paper shows different levels of electroacupuncture analgesia (antinociceptive effect) induced by three different frequencies of stimulation (i.e. 0.2, 4 and 200 Hz); highest analgesia is induced at 200 Hz and lowest at 0.2 Hz. Naloxone (1 mg/kg) completely reverses the electroacupuncture effects at low frequency stimulation (4 Hz) but produces no inhibition at high frequency stimulation (200 Hz). Conversely, parachlorophenylalanine (320 mg/kg) partially blocks the high-frequency (200 Hz) analgesia but produces no effect on the low-frequency (4 Hz) electroacupuncture analgesia. This suggests that electroacupuncture analgesia induced by low frequency stimulation may be mediated by endorphins while high frequency stimulation is not endorphinergic but may be partly due to serotonin.  相似文献   

20.
In unanaesthetized rabbits auriculo-acupuncture electrostimulation with frequency of 15 Hz decreased the amplitude of somatosensory EP second component in response to the tooth pulp electrostimulation which was blocked by intravenous injection of naloxone but not by intraventricular injection of saralasin. The same effect of auriculo-acupuncture electrostimulation with frequency 100 Hz was blocked by saralasin, was increased by angiotensin II, was diminished by methysergide but wasn't changed by naloxone. It's suggested that there is angiotensinergic antinociceptive mechanism of dental pain which is activated by auriculo-acupuncture electrostimulation with frequency 100 Hz.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号