共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Liu X Zheng H Tang W Qian Z Zhu Y Wang J Yuan S Wen X Cao C Chen H 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(25):2554-2560
Letosteine has been found to be effective in treating patients with chronic bronchopneumopathies in clinical practice. To provide robust support for its pharmacokinetic and clinical studies, a rapid and sensitive method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated for the analysis of letosteine in plasma samples. After protein precipitation, the plasma samples were separated on a reversed-phase C(18) column in less than 1.5 min. The LC-MS/MS system was performed in the positive ion multiple-reaction-monitoring (MRM) mode to produce intensive product ions of m/z 280.1→160.0 for letosteine and m/z 248.1→121.1 for the internal standard, tinidazole. The method was found to have excellent linearity (r ≥ 0.9974), precision (RSD ≤ 5.83%), extraction recovery (71.8-73.0%) and stability (RE, -8.45% to 9.03%) over a concentration range of 0.1140-152.0 μgL(-1). Compared to the previous published radioactive method, LC-MS/MS method showed many advantages including shorter analysis time, simpler preparation procedure, increased sensitivity as well as lower safety risks. In addition, this method was successfully applied to study the pharmacokinetics of letosteine following a single and multiple dose oral administration in Chinese healthy volunteers. 相似文献
3.
Cloperastine is a central antitussive used to reduce the frequency and intensity of coughing on a short-term basis. In this study, a reliable chiral LC-MS/MS technology has been developed for the quantification of cloperastine enantiomers in the rat plasma. Carbinoxamine was selected as the internal standard. The enantioseparation of cloperastine was performed on a Chiralpak IA column with a mobile phase composed of acetonitrile-water-ammonium hydroxide (80:20:0.1, v/v/v) at a flow rate of 0.6 mL/min. Cloperastine enantiomers were detected by mass spectrometry in multiple reaction monitoring mode with a positive electrospray ionization source. The method was validated over the linear concentration range of 0.05 to 10.0 ng/mL (5.0 × 10−4 ng to 0.10 ng) for both enantiomers. The lower limit of quantification (LLOQ) for each analyte was determined as 0.05 ng/mL. The relative standard deviations (RSDs) of intraday and interday precision was less than 13.9%, and the relative error (RE) of accuracy ranged from −5.4% to 6.1%, which were within the acceptance criteria. Finally, an application to the stereoselective pharmacokinetics of cloperastine in rats was successfully realized in our assay. The developed method on a commercially available Chiralpak IA column under isocratic mobile phase is advantageous to analyze cloperastine enantiomers in plasma samples collected for enantioselective metabolism or drug interaction studies. 相似文献
4.
Tong L Ding L Li Y Wang Z Wang J Liu Y Yang L Wen A 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(5-6):299-303
A sensitive and rapid LC-MS/MS method was developed and validated for the determination of levamisole in human plasma. The assay was based on liquid-liquid extraction of analytes from human plasma with ethyl ether. Chromatographic separation was carried on an Agilent HC-C(8) column (150 mm × 4.6 mm, 5 μm) at 40°C, with a mobile phase consisting of acetonitrile-10 mM ammonium acetate (70:30, v/v), a flow rate of 0.5 mL/min and a total run time of 6 min. Detection and quantification were performed by mass spectrometry in the multiple reaction monitoring mode with positive electrospray ionization m/z at 205.1→178.2 for levamisole, and m/z 296.1→264.1 for mebendazole (internal standard). The assay was linear over a concentration range of 0.1-30 ng/mL with a lower limit of quantification of 0.1 ng/mL. The coefficient of variation of the assay precision was less than 8.5%. The assay was successfully used to analyze human plasma samples in a pharmacokinetic study where levamisole was administered as a liniment. 相似文献
5.
Wu J Ding C Ge Q Li Z Zhou Z Zhi X 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(30):3475-3483
A novel, sensitive and specific LC-MS/MS method with silica-based solid-phase extraction was developed for simultaneous determination of ipratropium (IPR) and salbutamol (SAL) in rat plasma. Chromatographic separation was achieved on a Shiseido Capcell Pak CR column (SCX:C(18)=1:4, 150 mm × 2.0 mm, 5 μm) with a mobile phase consisting of methanol/water (85:15, v/v) containing 20 mmol/L ammonium formate and 0.1% formic acid at a flow rate of 0.3 mL/min. A tandem mass spectrometric detection with an electrospray ionization (ESI) interface was conducted via multiple reaction monitoring (MRM) under positive ionization mode. This method was validated in terms of specificity, linearity, accuracy (within ±115.4%), intra- and inter-day precision (<11.4%) over the concentration range of 8-1612 pg/mL for IPR and 50-10,000 pg/mL for SAL. In addition, stability and matrix effects of IPR and SAL in plasma were evaluated. This method has been successfully applied to the pharmacokinetic study of compound ipratropium bromide aerosol mainly containing ipratropium bromide (IB) and salbutamol sulphate (SS) after inhalation in rats. 相似文献
6.
Jia Y Wang G Xie H Dai X Wang Y Wang W Xu M Wang R Yao C 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,847(2):72-77
A sensitive and selective liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the identification and quantification of helicid in rat plasma. The method was based on simple liquid-liquid extraction (LLE). A Kromasil C18 column (150mmx2.00mm, 3.5microm) was used as the analytical column, while a mixture of acetonitrile and 500microM ammonium chloride was used as the mobile phase. MS detection was performed using a single quadrupole mass spectrometer in a negative selected ion monitoring (SIM) mode. The deprotonated molecules [M+Cl](-) at m/z 319.00 and 363.05 were used to quantify helicid and bergeninum (internal standard, I.S.), respectively. The lower limit of quantification of helicid was 1ng/ml. The method was linear in the concentration range of 1-1000ng/ml. The intra-day and inter-day precisions (R.S.D.%) were within 10.0% for the analyte. Helicid proved to be stable during all sample storage, preparation and analytical periods. The method was successfully applied to a pharmacokinetic study in rats after intragastric administration of helicid with a dose of 50mg/kg. Only 50microl of rat plasma at each sampling time was needed for analysis. The proposed method enables unambiguous identification and quantification for the preliminary pharmacokinetic studies of helicid. 相似文献
7.
Geng-Nan Wang Rui-Le Pan Yong-Hong Liao Ying Chen Jing-Tian Tang Qi Chang 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(1):102-106
A highly sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed for the determination of forsythiaside in rat plasma using epicatechin as internal standard. The analytes were extracted by solid-phase extraction and chromatographied on a C18 column eluted with a gradient mobile phase of acetonitrile and water both containing 0.2% formic acid. The detection was performed by negative ion electrospray ionization in multiple reaction monitoring mode, monitoring the transitions m/z 623 → 161 and m/z 289 → 109 for forsythiaside and epicatechin, respectively. The assay was linear over the concentration ranges of 2.0–50.0 and 50.0–5000.0 ng/mL with limits of detection and quantification of 0.2 and 1.0 ng/mL, respectively. The precision was <10.8% and the accuracy was >91.9%, and extraction recovery ranged from 81.3% to 85.0%. This method was successfully applied to a pharmacokinetic study of forsythiaside in rats after intravenous (20 mg/kg) and oral (100 mg/kg) administration, and the result showed that the compound was poorly absorbed with an absolute bioavailability being approximately 0.5%. 相似文献
8.
Shi R Qiao S Yu D Shi X Liu M Jiang X Wang Q Zhang L 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(19):1625-1632
A new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the determination of five flavonoids including scutellarin, naringenin, apigenin, luteoline and wogonin in rat plasma using sulfamethalazole as internal standard (IS). Plasma samples were pretreated with liquid-liquid extraction procedure and acid hydrolysis method was used for converting conjugated flavonoids to their respective free forms. The chromatographic separation was performed on a C(18) column with a linear gradient elution using a mobile phase consisted of 0.01% acetic acid and methanol. The detection was accomplished by multiple-reaction monitoring (MRM) scanning with electrospray ionization (ESI) source operating in the negative ionization mode. The optimized mass transition ion-pairs (m/z) monitored for scutellarin, naringenin, apigenin, luteoline, wogonin and IS were 461.1/285.1, 271.0/119.0, 269.0/117.0, 285.0/132.9, 283.0/268.0 and 252.0/155.9, respectively. The method was linear for all analytes over investigated ranges with all correlation coefficients greater than 0.9915. The lower limit of quantitation (LLOQ) of scutellarin was 9.15 ng/mL and other compounds were all less than 2.0 ng/mL. The proposed method showed appropriate accuracy and repeatability and was suitable for pharmacokinetic studies of the five flavonoids after oral administration of Scutellaria Barbata extract. 相似文献
9.
Liu Q Liu X Luo G Tian W Wang Y 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2006,832(2):185-190
A simple, rapid and reliable method was developed for the identification and quantification of helicidum and its metabolites in beagle dog plasma by liquid chromatography/ultra-violet/electrospray ionization-ion trap mass spectrometry (LC/UV/ESI-ITMS). Two metabolites were identified by MS: formylphenyl-O-beta-d-pyranosyl alloside (I) and hydroxylmethylphenyl-O-beta-d-pyranosyl alloside (II). UV was used for concentration determination with the wavelength of 270 nm. Liquid-liquid extraction was used and the extraction recovery exceeded 90%. Kromacil C(18) column (5 microm, 4.6mm i.d. x 250 mm) was used as the analytical column. Linear detection responses were obtained for helicidum concentration ranging from 1.76 x 10(-4) to 70.4 x 10(-4) micromol/mL (0.050-2.00 microg/mL). The precision and accuracy data, based on intra- and inter-day variations over 3 days, were less than 5%. The limit of determination and quantitation (LOD, LOQ) for helicidum was 0.010 and 0.030 microg/mL, respectively. Pharmacokinetic data of helicidum and the two metabolites were obtained with this method after administration of intravenous injection and a single oral dose of tablets to six beagle dogs, respectively. 相似文献
10.
11.
H. Laufen F. Scharpf G. Bartsch 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1978,146(3):457-464
A rapid, accurate and highly sensitive method was developed for the determination of isosorbide dinitrate in human plasma. Concentrations in the lower nanogram and subnanogram range are determined by a one-step extraction of 2 ml plasma, containing 4 ng/ml nitroglycerine as internal standard, with 5.5 ml n-pentane. The extract is subjected to gas—liquid chromatography—electron capture detection analysis. The lower limit of quantitation is 200 pg/ml, but concentrations as low as 50 pg/ml are still detectable. The method allows the quantitative determination of isosorbide dinitrate plasma levels in man following a 5 mg sublingual administration up to four hours after application. 相似文献
12.
Hansen RJ Samber BJ Gustafson DL 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(32):3432-3436
Felbamate (2-phenyl-1,3-propanediol dicarbamate) is a second generation antiepileptic drug used to treat seizures refractory to other antiepileptic drugs. With approximately 3500 new patients exposed annually, several important pharmacologic interaction questions remain unanswered necessitating the need for rapid and accurate methods of felbamate analysis in biological matrices. To this end, a rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for the measurement of felbamate in mouse plasma and tissues and human plasma. Plasma (100 μL) and tissues homogenates (100 μL of 100 mg/mL) were spiked with internal standard (carisoprodol) prior to protein precipitation with acetonitrile. Samples were chromatographed on a XBridge Phenyl, 2.5 μm, 4.6 mm×50 mm column with quantitation by internal standard reference monitoring of the ion transitions m/z 239→117 for felbamate and m/z 261→176 for carisoprodol. Calibration curves were linear from 2.5 to 500 ng/mL in mouse or human plasma and 25-5000 pg/mg in tissue homogenates. Recoveries were greater than 97% for plasma and homogenates with accuracies >92% in any of the mouse matrices and >88% in human plasma. Comparable accuracies and precision were found with and without the use of the internal standard in preparation of the calibration curves and suggest that the internal standard may not be required. 相似文献
13.
Gao S Miao H Tao X Jiang B Xiao Y Cai F Yun Y Li J Chen W 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(21):1939-1944
A rapid and sensitive method using liquid chromatography-tandem mass spectroscopy (LC-MS/MS) was developed and validated for simultaneous quantitative determination of valproic acid and three major metabolites (3-OH-valproic acid, 4-ene-valproic acid and 5-OH-valproic acid) in human plasma. The analytes and internal standard were isolated from 200 μL samples by solid phase extraction using a ZORBAX SB-C? column (3.5 μm, 2.1×100 mm) with an isocratic mobile phase consisting of methanol-10mM ammonium acetate (80:20, v/v) containing 0.1% formic acid at a flow rate of 0.3 mL/min. The method had a chromatographic total run time of 2.0 min. The lower limit of quantification of valproic acid, 3-OH-valproic acid, 4-ene-valproic acid and 5-OH-valproic acid of the method was 2030, 51.5, 50.15 and 51.25 ng/mL, respectively. The method was linear for valproic acid and the three metabolites with correlation coefficients >0.995 for all analytes. The intra-day and inter-day accuracy and precision of the assay were less than 15.0%. This analytical method was successfully used to assay plasma concentrations of valproic acid and the three metabolites in human plasma from epileptic patients. 相似文献
14.
Mistri HN Jangid AG Sanyal M Shrivastav P 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,850(1-2):318-326
A simple, sensitive and rapid liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and validated to quantify griseofulvin in human plasma using propranolol hydrochloride as internal standard (IS). Samples were prepared using solid phase extraction and analysed without drying and reconstitution. The analytes were chromatographed on Hypersil, hypurity C18 reverse phase column under isocratic conditions using 0.05% formic acid in water:acetonitrile (30:70, v/v) as the mobile phase. Total chromatographic run time was 3.0 min. Quantitation was done on a triple quadrupole mass analyzer API-3000, equipped with turbo ion spray interface and operating in multiple reaction monitoring (MRM) mode to detect parent-->product ion transition for analyte and IS. The method was validated for sensitivity, matrix effect, accuracy and precision, linearity, recovery and stability studies. Linearity in plasma was observed over the concentration range 20-3000 ng/mL for griseofulvin. Lower limit of quantification (LLOQ) achieved was 20 ng/mL with precision (CV) less than 10% using 5 microL injection volume. The absolute recovery of analyte (87.36%) and IS (98.91%) from spiked plasma samples was consistent and reproducible. Inter-batch and intra-batch coefficients of variation across four validation runs (LLOQ, LQC, MQC and HQC) was less than 7.5%. The accuracy determined at these levels was within +/-4.2% in terms of relative error. The method was applied to a pilot bioequivalence study of 500 mg griseofulvin tablet in six healthy human subjects under fed condition. 相似文献
15.
Xie J Ding C Ge Q Zhou Z Zhi X 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,864(1-2):87-94
A new liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of ginkgolides (includes ginkgolide C for the first time) and bilobalide in plasma is presented. Ketoprofen was used as an internal standard, and sample pre-treatment consisted of a liquid-liquid extraction. Chromatographic separation was achieved on a 5 microm Shiseido C8 column (150 mm x 2.0 mm i.d., particle size 5 microm) with a mobile phase consisting of methanol/ 6 mM ammonium acetate (60/40, v/v) at a flow rate of 0.3 ml/min. A tandem mass spectrometric detection was conducted using multiple reaction monitoring (MRM) under negative ionization mode with an atmospheric pressure chemical ionization (APCI) interface. The method was validated in terms of intra- and inter-day precision (<12.7%), accuracy (within +/- 7.0%), linearity, specificity and stability. In addition, matrix effects of ginkgolides and bilobalide in plasma were evaluated in different reconstitution solvents. Smaller matrix effects were observed for reconstitution solvents containing less organic solvent. The method has been successfully applied to a pharmacokinetic study of Ginkgo biloba extract in rats after intravenous administration. This is the first report of pharmacokinetic data for ginkgolide C. 相似文献
16.
Development and validation of a LC-MS/MS method for the determination of viaminate in human plasma 总被引:1,自引:0,他引:1
Yin J Ni KY Shen Y Ma PC Cao L Wang WP Wang Y 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,856(1-2):376-380
A sensitive and specific method for determination of viaminate in human plasma by using high-performance liquid chromatography coupled with electrospray tandem mass spectrometry (LC-MS/MS) was developed in this study. The plasma samples were simply deproteinated, extracted, evaporated, and then reconstituted in 200 microl of methanol prior to analysis. Chromatographic separation was carried out on a Shimadzu VP-ODS column (250 mm x 2.0 mm, 5 microm) with a mobile phase of methanol-water (95:5, v/v) at a flow rate of 0.2 ml/min. Quantification was performed in the negative-ion electrospray ionization mode by selected ion monitoring of the product ions at m/z 164 for viaminate and m/z 109 for testosterone propionate which was used as the internal standard. The corresponding parent ions were m/z 446 and m/z 345. A linear calibration curve was observed within the concentration range of 0.10-200 ng/ml. The lowest limit of quantitation (LLOQ) was 0.1 ng/ml. The extraction-efficiency at three concentrations was 100.7, 93.6, and 99.7%. Practical utility of this new LC-MS/MS method was confirmed in pilot pharmacokinetic studies in humans following oral administration. 相似文献
17.
Premanand Ranganathan V. Gunasekaran Indrajeet Singhvi Mohammad Javed Ansari 《Saudi Journal of Biological Sciences》2019,26(7):1843-1847
A highly sensitive and ultra-fast high performance liquid chromatography- tandem mass spectrometry (LC–MS/MS) assay is developed and validated for the quantification of Lenalidomide in human plasma. Lenalidomide is extracted from human plasma by Liquid- Liquid Extraction by Ethyl Acetate and analyzed using a reversed phase isocratic elution on a XTerra RP18, (4.6 × 50 mM, 5 µm) column. A 0.1% Formic acid: Methanol (10:90% v/v), is used as mobile phase and detection was performed by Triple quadrupole mass spectrometry LC-MS/MS using electrospray ionization in positive mode. Fluconazole is used as the internal standard. The lower limit of quantification is 9.999 ng/mL for Lenalidomide. The calibration curves are consistently accurate and precise over the concentration range of 9.999 to 1010.011 ng/mL in plasma for Lenalidomide. This novel LC–MS/MS method competes with all the regulatory requirements and shows satisfactory accuracy and precision and is sufficiently sensitive for the performance of pharmacokinetic and bioequivalence studies in humans. 相似文献
18.
Li QY Su L Zu YG Zhang L Gao Y Wang CC Zhu QC Deng XQ 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(7-8):461-466
A new, simple, sensitive and specific reversed-phase high performance liquid chromatographic (HPLC) method using tandem mass spectrometry detection was initially developed and validated for the analysis of 10-(2-pyrazolyl-ethoxy)-(20S)-camptothecin (CPT13) in rat plasma. Pretreatment of the sample obtained from plasma involved a single protein precipitation step with using acetonitrile containing 0.1% formic acid. An aliquot of 20 μl was injected into a C-18 column. The chromatographic separation was achieved using the mobile phase consisting of acetonitrile:water (35:65) at a flow rate of 1.0 mL/min. The total run time for each sample was 10 min, and camptothecin (CPT, IS) and CPT13 were well separated with retention times of 5.1 min and 5.6 min, respectively. Detection was performed using a triple quadrupole tandem mass spectrometer in multiple reaction monitoring (MRM) mode via an electrospray ionization (ESI) source. The calibration curve was linear (r2 = 0.9998) over the concentration range of 1-1000 ng/mL, with a LLOQ of 1 ng/mL for CPT13. The inter- and intra-day precision (%R.S.D.) were <2.58% and 6.28%, respectively, and the accuracies (%) were within the range of 97.34-110.67%. CPT13 in rat plasma was stable when stored at -20 °C or 4 °C for three freeze-thaw cycles, The method was employed for the first time during pharmacokinetic studies of CPT13 in rats following a single intravenous dose (0.1 mg/kg) and three different oral doses (50 mg/kg, 30 mg/kg, and 10 mg/kg). This fully validated method was successfully applied to a pharmacokinetic study of CPT13 in rats. 相似文献
19.
A HPLC method for determination of nicousamide in dog plasma and its application to pharmacokinetic studies 总被引:1,自引:0,他引:1
Sheng L Chen H Li Y 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,854(1-2):99-103
A sensitive and reproducible high performance liquid chromatography (HPLC)-UV method for determination of nicousamide, an inhibitor of rennin and transforming growth factor-beta1 (TGF-beta1) type II receptors, has been developed and validated. Following acetonitrile deproteiniation, samples were separated by isocratic reversed-phase HPLC on an Aichrom Bond-AQ C(18) column and quantified using UV detection at 320 nm. The mobile phase was acetonitrile/water (ratio 62:38 containing 0.1% H(3)PO(4)), with a flow-rate of 1.0 ml/min. A linear curve over the concentration range 5-200 ng/ml (r(2)=0.9978) was obtained. The coefficients of the variation for the intra- and inter-day precisions ranged from 1.4-10.7% and 1.8-7.1%, respectively. The percentage of relative recovery was 91.56-105.45%. The method was used to determine the plasma concentration-time profiles for nicousamide after oral doses of 30, 100 and 300 mg/kg in dogs. A nonlinear pharmacokinetics was found in dogs at doses from 30 to 300 mg/kg. Following 30 mg/kg oral dose, the C(max) and AUC in females were lower than that in male. There is a potential for accumulation in dogs following multiple doses. 相似文献
20.
Wen A Yang J Jia Y Yang Z Tian Y Wu Y Wang Z He Z 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,876(1):41-46
A sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the determination of hydroxysafflor yellow A (HSYA) in human plasma. HSYA was extracted from human plasma by using solid-phase extraction technique. Puerarin was used as the internal standard. A Shim-pack VP-ODS C(18) (150mm x 4.6mm, 5 microm) column and isocratic elution system composing of methanol and 5mM ammonium acetate (80:20, v/v) provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 611.19-->491.19 for HSYA and m/z 415.19-->295.10 for puerarin. The proposed method has been validated with a linear range of 1-1000 ng/ml for HSYA with a correlation coefficient >/=0.999. The lower limit of quantitation was 1 ng/ml. The intra-batch and inter-batch precision and accuracy were within 10%. The average extraction recovery was 81.7%. The total run time was 5.5 min. The validated method was successfully applied to the study on pharmacokinetics of HSYA in 12 healthy volunteers after a single oral administration of safflower oral solution containing 140 mg of HSYA. 相似文献