首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The plasma concentration of 11β-hydroxy-4-androstene-3,17-dione (11β) is very high in 21-hydroxylase deficiency, Cushing’s syndrome, and hyperandrogenism of adrenal origin, and very low in congenital 11-hydroxylase deficiency and adrenal insufficiency. Thus, when plasma 4-androstenedione is elevated, it is useful to measure the plasma 11β level in order to determine the adrenal or ovarian origin of the hyperandrogenism.

To eliminate disadvantages related to the 11β radioimmunoassay (RIA), which uses a tritiated tracer, as well as the high cost associated with scintillation proximity assay (SPA), we developed a non-isotopic 11β assay that utilizes an 11β-biotin conjugate synthesized in our laboratory to measure time-resolved fluorescence after addition of streptavidin-europium to microtitration wells.

The analytical qualities of this assay are very similar to those of the radioimmunoassay using a tritiated tracer, and an extraction step followed by celite chromatography (which separates 11β from interfering plasma steroids) prior to a final radioimmuno-competition step. The correlation coefficient between 11β levels measured by time-resolved plasma 11β fluoroimmunoassay (TR-FIA) and RIA was 0.965.

Finally, the TR-FIA technique was more sensitive and of greater precision than the RIA method.  相似文献   


2.
In this article we described, for the first time to our knowledge, the development of a new non isotopic immunoassay (time resolved-fluoroimmunoassay) for determining 17alpha-hydroxypregnenolone levels in plasma or serum. This steroid is indeed the most relevant steroid for the diagnosis of 3beta-hydroxysteroid dehydrogenase deficiency. For the hapten tracer, we synthesized a biotin-oxyacetyl 17-hydroxypregnenolone conjugate. A specific polyclonal rabbit anti-17-hydroxypregnenolone was indirectly bound via an immobilized sheep anti-rabbit antibody on microtiter plate wells. The amount of biotin-17-hydroxypregnenolone conjugate bound was then measured by adding Streptavidin-Europium, and the Europium fluorescence was quantified by Time Resolved -Fluorescence (TR-FIA, Delfia System). The plasma 17-hydroxypregnenolone levels of this non isotopic assay were comparatively measured with a radioimmunoassay previously published and using the same anti 17-hydroxypregnenolone antibody. In both cases, the assays were performed after a extraction step and a chromatographic step. The sensitivity of this 17-hydroxypregnenolone time resolved-fluoroimmunoassay was higher than that of 17-hydroxypregnenolone radioimmunoassay. The compared results of plasma 17-hydroxypregnenolone, performed with these two methods were not significantly different. A practical advantage is the stability of the biotine tracer, comparatively to the radioactive 125I 17-hydroxypregnenolone tracer which requires a new labeling every two months.  相似文献   

3.
4.
We have developed a non-isotopic TR-FIA for Cyproterone acetate and Cyproterone in plasma. Synthesis of the biotinylated tracers, biotinylated Cyproterone acetate, and Cyproterone, as well as the preparation of anti–Cyproterone acetate and anti-Cyproterone antisera are reported. The specificity of anti-Cyproterone acetate antiserum resulting from the coupling of link bridge (link bridge between steroid and BSA), on the 3-position on the steroid skeleton, allowed to carry out the Cyproterone acetate assay directly on extracted plasma (without chromatography). On the other hand Cyproterone assays require a purification step, including extraction plus chromatography, because the plasma Cyproterone acetate concentrations in Cyproterone acetate-treated women are 200 times higher than for Cyproterone. Theses plasma TR-FIA of Cyproterone acetate and Cyproterone presented the advantage of needing only small doses of radioactivity for recovery controls, and better praticability related to the only existing RIA described to date.  相似文献   

5.
We describe, for the first time to our knowledge, the development of a new, non-isotopic time resolved-fluoroimmunoassay of 4-androstene-3,17-dione in plasma or serum. This steroid exhibits a key role in steroid metabolism and is often assayed in the investigation of various pathologic endocrine states. Most of the 4-androstene-3,17-dione immunoassays are performed using a radioactive tracer. We synthesized a biotinylated 4-androstene-3,17-dione tracer from 4-androstene-3,17-dione-3-carboxymethyloxime by acylation of biotinylaminopropylammonium trifluoroacetate. A specific rabbit anti 6-hemisuccinate-4-androstene-3,17-dione/BSA was indirectly bound via an anti-rabbit sheep antibody immobilized on microtiter plate wells. The amount of biotinylated-4-androstene-3,17-dione tracer was then measured by adding streptavidin-europium, and the europium fluorescence was quantified by time resolved-fluorescence (TR-FIA, Delfia System). The plasma 4-androstene-3,17-dione-levels measured with this non-isotopic assay were compared to those measured with a radioimmunoassay previously published. In both cases, the same anti-4-androstene-3,17-dione antibody was used, and the assays were performed after an extraction step and a chromatographic step. The results obtained by the two methods were virtually the same. However, the main advantages of the new plasma 4-androstenedione-3,17-dione time-resolved-fluorescence immunoassay were its greater sensitivity than radioimmunoassay and its higher precision.  相似文献   

6.
7.
A comparison of a solid-phase immunoassay using time-resolved fluorescence (TR-FIA) and a conventional radioimmunoassay (RIA) was performed for the determination of total serum testosterone in peripheral blood samples obtained from 231 mink males (Mustela vison). The correlation between the values obtained with the two methods was good (r=0.85;y=1.52+1.05x). The values obtained with FIA (11.67±6.70 ng/ml) were slightly higher than those obtained with RIA (9.64±5.39 ng/ml). Standards prepared from female mink serum behaved similarly to the bovine serum standards used in the commercial kits. The data obtained show that FIA is a reproducible method and provides a useful tool for measurement of a large number of samples within a short period of time.  相似文献   

8.
9.
A radioimmunossay (RIA) for the measurement of both unconjugated and total serum estetrol has been developed, using an antiserum to an E4-3-conjugate and a 125I-radioiodinated E4 tracer. Assay of dried ethyl ether extracts was used for the determination of unconjugated E4, while a direct measurement of unextracted hydrolyzed serum in the presence of 0.3% 8-anilino-1-naphthalene sulphonic acid (ANS) proved adequate for total E4. Assay reliability was evaluated and the procedure standardized through a series of tests aimed at assessing accuracy, sensitivity and precision. No steroidal interference was found to practically affect the assay (0.3% estriol cross-reactivity), nor were solvent and sample blanks observed in the case of unconjugated E4. For total E4 assay, the sample blank effects were acceptably overcome by using hydrolyzed male serum and 0.3% ANS, as a standard diluent. An interassay variability amounting to approximately 10 and 6% resulted for unconjugated E4 and total E4 RIA, respectively. A number of serum samples (285 for unconjugated E4, 147 for total E4) randomly collected throughout normal pregnancy were assayed. The unconjugated E4 levels at 15th week and at term were 62.7 +/- 22.6 and 766.5 +/- 208.2 (SD) pg/ml, respectively. Total E4 was about 6--7 times higher than the levels of free E4 and increased 7 times from the 15th week to term.  相似文献   

10.
We present a quantitative measurement of specific antitetanic IgG immunoglobulins with protein "A" labeled with I125. The Laurell's immunoelectrophoresis was the reference method. After having fixed optimum conditions of duration and temperature of de reaction, we studied the different concentrations of the coated antigen and also the different dilution of serum. We can so eliminate the most aspecific effects of the antigen-antibody reaction. The correlation between the two methods of measurement is more than 98%.  相似文献   

11.
The existence of a mammalian natriuretic substance or endogenous digitalis-like factor, which inhibits Na+,K+-ATPase and thereby regulates body fluid volume, has been speculated for a long time but has yet to be defined. We established in the present study a simple and highly sensitive procedure to measure bufalin, a constituent of toad venom preparation and a specific inhibitor of Na+,K+-ATPase by time-resolved fluoroimmunoassay (TR-FIA) and using a monoclonal antibody. The antibody was specific to bufalin and resembled bufadienolides but showed no cross-reactivity with digitoxin and ouabain. A bufalin-like immunoreactivity was detectable in serum of humans and rats by the proposed TR-FIA. The levels of bufalin-like immunoreactivity in serum of healthy volunteers were significantly correlated with their systolic blood pressure. Moreover, bufalin-like immunoreactivity in serum of Dahl-S rats increased in parallel with a period of high-salt diet. These results suggest that increased bufalin-like immunoreactivity may be associated with certain types of hypertension.  相似文献   

12.
Fiet J  Giton F  Auzerie J  Galons H 《Steroids》2002,67(13-14):1045-1055
We describe the development of a serum chlormadinone acetate (CMA) time-resolved fluoroimmunoassay (TR-FIA). We prepared haptens (3-CMO-chlormadinone acetate and 6-chloropregna-4,6-dien-17,20-diol-3-one-20-hemisuccinate), biotinylated tracers (3(biotinylaminopropylamido) 3-CMO-chlormadinone acetate and 3-(6-chloropregna-4,6-dien-17,20-diol-3-one-20-hemisuccinylamino)1-biotinylaminopropane), and immunogens necessary for eliciting two antibodies (anti-chlormadinone acetate 3-CMO/BSA and anti-chlormadinone 20-hemisuccinate/BSA). The specificity of the assay was rigorously studied to eliminate possible interference by polar metabolites of CMA, particularly 17 alpha-acetoxy-6-chloro-3beta-hydroxypregna-4,6-diene-20-one (3beta-hydroxy metabolite), employing an easy-to-use ethylene glycol chromatographic step prior to immunoassay, so as to separate the polar metabolites, in particular the 3beta-hydroxy-CMA metabolite, from the intact CMA. The choice of the anti-CMA antibody was guided by the high assay sensitivity obtained with the anti-CMA 3-CMO/BSA antibody. The detection limit was 51pg/ml. Interassay reproducibility CVs were between 2.6 and 4.5%. This TR-FIA thus appeared to be a sensitive, specific, precise, and consequently well-suited method for measurement of serum CMA during a pharmacokinetic study in women.  相似文献   

13.
Most pandalid shrimps exhibit protandric hermaphroditism, and detailed information on ovarian development of pandalid species is important for a better understanding of vitellogenesis in crustacean species. In the present study, we characterized ovarian development under light and electron microscopy and examined the hemolymph vitellogenin levels in the coonstriped shrimp, Pandalus hypsinotus under laboratory conditions. To measure vitellogenin levels, a time-resolved fluoroimmunoassay (TR-FIA) was developed after purification of vitellin and production of the anti-vitellin antiserum. The TR-FIA showed wide assay range (0.98-2000 ng/ml), high sensitivity (0.5 ng/ml), and low assay variability (0.9-6.4% of intraassay coefficients, 1.4-5.1% for interassay coefficients). Female P. hypsinotus had non-vitellogenic ovaries in March after the eggs attached to the abdomen hatched, and started yolk accumulation in the ovaries during April-October. During yolk accumulation, yolk globules appeared and increased in the ooplasm. After yolk accumulation, gonadosomatic index (GSI) reached 8.3-8.5 just before oviposition. Females spawned and were ovigerous during June-July of the next year. Hemolymph vitellogenin levels were low (0.006+/-0.008 mg/ml, mean+/-SD) before the yolk accumulation, and became significantly higher (2.66 +/-0.93 mg/ml) during yolk accumulation (GSI, 2-8). Just before oviposition, levels declined to low levels (0.040+/-0.012 mg/ml). Vitellogenin levels were significantly correlated to GSI during the yolk accumulation. The obtained results show that the process of vitellogenesis during the female phase of P. hypsinotus is similar to other crustacean species that do not change sex.  相似文献   

14.
Cortisol has been shown to be metabolized in the zona glomerulosa of the adrenal gland through the same pathway involving the cytochrome P-450, corticosterone methyl oxidase by which corticosterone is transformed to 18-hydroxycorticosterone and aldosterone. When cortisol is the precursor, 18-hydroxycortisol and 18-oxocortisol are formed. 18-Hydroxycortisol can also be made at a similar rate in the bovine zona fasciculata and reticularis as in the zona glomerulosa. We studied the possibility that the formation of 18-hydroxycortisol in the zona fasciculata and reticularis might be through a different pathway involving initial 18-hydroxylation of 11-deoxycortisol before 11 beta-hydroxylation. Rat adrenal capsules or cores were incubated with 10 micrograms of cortisol or 11-deoxycortisol and the formation of 18-hydroxycortisol was measured by radioimmunoassay. Both capsules and cores transformed 11-deoxycortisol to 18-hydroxycortisol, but cortisol was only transformed in the capsular portion. Sixty-two rat adrenals were incubated with 10 mg of 11-deoxycortisol and the putative steroid, 18-hydroxy-11-deoxycortisol, was purified by TLC and HPLC and subjected to gas chromatography mass spectrometry. The mass spectra indicated that the steroid isolated was indeed 18-hydroxy-11-deoxycortisol. The function of this steroid is still unknown.  相似文献   

15.
Recently, a system that measures tissue oxygen tension using time-resolved luminescence-based optical sensors has become available commercially (Oxford Optronix, Oxford, England). Two experiments were conducted using this system. First, the oxygen tension distribution was measured in two tumor lines: a spontaneous mouse fibrosarcoma, FSa-II, and a human squamous cell carcinoma xenograft, FaDu. The area in which the pO(2) was equal to or lower than 2.5 mmHg was defined as the hypoxic lesion, and the hypoxic cell fraction was taken as the fraction of these measurements in a tumor. The measured hypoxic cell fractions were compared with those determined by the paired cell survival assay for tumors of various sizes. Second, the tumor tissue pO(2) was measured continuously after administration of two different anesthetics to evaluate the effect of these drugs on tissue pO(2). Results indicated a good agreement between the hypoxic cell fractions measured by this system and those determined by the paired cell survival curve assay for tumors smaller than approximately 500 mm(3). For tumors larger than approximately 500 mm(3), the hypoxic cell fractions measured by the oxygen probe system were higher than those measured by the paired cell survival assay. This may suggest that the hypoxic cell fraction measured by the oxygen probes included both hypoxic and necrotic areas in large tumors where necrotic lesions occupied a significant portion of the tumor. Continuous measurements of pO(2) after anesthesia (Nembutal, or ketamine plus xylazine) showed a consistent rise in the pO(2) during the first 20-30 min of measurement. Subsequently, the pO(2) values became constant or continued to rise slowly. For comparison, the tumor cell survivals were assayed after a dose of 20 Gy given in air at 5, 20 and 60 min after anesthesia. The result showed a decrease in cell survival only in tumors irradiated 20 min after an injection of Nembutal.  相似文献   

16.
17.
The authors have shown an heterogeneity of the ovine prolactine molecule after labelling with iodine 125. As well with chloramine T as with lactoperoxydase, it appears three molecular species which react with the immune serum antiprolactine (I.S.). The first species is of high molecular weight and is probably constituted of aggregates. Their combination with the I.S. is non specific and give blanks of high value. The second species is a dimere and the third one is the monomere. The two last species react with the I.S. and can give competition curves when they are choosen as tracer. However, if one uses as tracer a product obtained by labelling with chloramine T, the competition appears for high concentrations of native hormone. As if the I.S. recognizes much more the labelled protein than the native one. But if one uses the same species but labelled with lactoperoxydase, the competition appears for concentrations lower than five nanogrammes. In the same time one can see that the specificity toward different I.S. is modified. The authors think that the labelling with lactoperoxydase better preserves the tertiary structure of the native protein than do the labelling with chloramine T.  相似文献   

18.
The regional distribution of somatostatin binding sites in the rat brain was determined by quantitative autoradiography, using 125I-CGP 23996, a non-reducible somatostatin analog. In preliminary experiments, kinetic properties of 125I-CGP 23996 binding to rat brain membranes and slide mounted frozen brain sections were compared and found similar. In addition, distribution of 125I-CGP 23996 and 125I-N-Tyr-SRIF14 binding sites on membrane prepared from 10 different rat brain structures were closely correlated (r = 0.91, 2 p less than 0.01), indicating that the non-reducible analog recognizes the same binding site as the Tyr-extended native peptide. Highest levels of 125I-CGP 23996 binding sites were found in anterior temporal, frontal and cingular cortex as well as hippocampus. Moderate levels were found in the remaining part of the limbic system including amygdala, olfactory tubercles and bed nucleus of the stria terminalis. In the brain stem, nuclei involved in the auditory system such as the ventral cochlear nucleus and the superior olive nucleus, contained high levels of 125I-CGP 23996 binding sites. The distribution of 125I-CGP 23996 binding sites roughly correlated with that of the endogenous peptide in most structures, except in the mediobasal hypothalamus.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号