首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
Nelfinavir mesylate, a potent and orally bioavailable inhibitor of HIV-1 protease (Ki=2 nM), has undergone Phase III clinical evaluation in a large population of HIV-positive patients. A high-performance liquid chromatography analytical method was developed to determine the pharmacokinetic parameters of the free base, nelfinavir, in these human subjects. The method involved the extraction of nelfinavir and an internal standard, 6,7-dimethyl-2,3-di-(2-pyridyl)quinoxaline, from 250 μl of human plasma with a mixture of ethyl acetate–acetonitrile (90:10, v/v). The analysis was via ultraviolet detection at 220 nm using a reversed-phase C18 analytical column and a mobile phase consisting of 25 mM monobasic sodium phosphate buffer (adjusted to pH 3.4 with phosphoric acid)–acetonitrile (58:42, v/v) that resolved the drug and internal standard peaks from non-specific substances in human plasma. The method was validated under Good Laboratory Practice (GLP) conditions for specificity, inter- and intra-assay precision and accuracy, absolute recovery and stability. The mean recovery ranged from 92.4 to 83.0% for nelfinavir and was 95.7% for the internal standard. The method was linear over a concentration range of 0.0300 μg/ml to 10 μg/ml, with a minimum quantifiable level of 0.0500 μg/ml for nelfinavir.  相似文献   

3.
A reversed-phase isocratic high-performance liquid chromatographic method has been developed for the determination of AG-331, a novel thymidylate synthase inhibitor, in human serum and urine. The method involves a solid-phase extraction from C18 cartridges without addition of an internal standard. The methanol eluent is evaporated under nitrogen at 40°C, and reconstituted in mobile phase, acetonitrile-water (35:65, v/v) containing 25 mM ammonium phosphate. Separation of AG-331 was obtained on a C18 column at a flow-rate of 1 ml/min. Chromatographic signals were monitored by a photodiode-array detector at a primary wavelength of 457 nm with a bandwidth of 4.8 nm. Standard curves are linear in the range of 22–2175 ng/ml in plasma and 44–2175 ng/ml in urine, respectively. The extraction recovery ranged from 92.9–102.4%. Intra-day coefficient of variation was less than 9.5%, and inter-day coefficient of variation was less than 14.3% for an AG-331 concentration of 44 ng/ml. This method has been used to characterize the pharmacokinetics of AG-331 in cancer patients as part of ongoing Phase I trials.  相似文献   

4.
A sensitive high-performance liquid chromatography (HPLC) method using UV detection for the determination of gabapentin in human plasma has been developed. In this method, gabapentin was extracted from human plasma with a reversed-phase solid-phase extraction (SPE) cartridge followed by derivatization with phenylisothiocyanate. Analysis was achieved by using a HPLC system that was equipped with a UV detector. The quantitation limit of gabapentin in human plasma was 0.03 microg/ml. The method is sensitive with excellent selectivity and reproducibility and it has been applied to a bioequivalence clinical study with great success.  相似文献   

5.
A reversed-phase, column-switching high-performance liquid chromatographic (HPLC) method is described for the determination of a new thymidylate synthase inhibitor in human plasma. The compound and an internal standard are extracted from plasma using a Certify II solid-phase cartridge. Extracts are evaporated to dryness and the residue is reconstituted with mobile phase buffer. The analytes are separated from polar interferences and buffer salts originating from the elution step on a 4-mm YMC Basic pre-column. The fraction containing the analytes is further separated on a 25-cm YMC Basic column. The analytes are detected by their absorbance at 250 nm. The limit of quantitation is 10 ng/ml. The method is linear from 10 ng/ml to 80 μg/ml using three standard curve ranges. Validation studies for all three ranges show the method to be reproducible. The method has been successfully used to support pharmacokinetic studies.  相似文献   

6.
7.
A method for the quantification of mycophenolate mofetil (MMF, CellCept) in plasma using solid-phase extraction and HPLC is described here. A solution of internal standard is added to a 0.5-ml plasma aliquot. The resulting sample is treated with water and dilute HCl and applied to a C18 solid-phase extraction column. After a water wash, the MMF and internal standard are eluted with methanol-0.1 M citrate-phosphate buffer, pH 2.6 (80:20, v/v). A 20-μl aliquot of the eluate is injected onto a C18 column (5 μm particle size, 150 × 4.6 mm I.D.) and eluted at ambient temperature with acetonitrile-0.05 M citrate-phosphate buffer, pH 3.6, containing 0.02 M heptanesulfonic acid (41:59, v/v). Quantification is achieved by UV detection at 254 nm. The method is reproducible, accurate and specific for MMF. Using 0.5 ml of plasma for analysis, the quantification limit is 0.400 μg/ml and the range is 0.400–20 μg/ml. Based on the stability profile of MMF in plasma, it is recommended that blood samples collected following intravenous infusion be immediately stored on ice and that plasma be prepared rapidly, immediately stored frozen at −80°C and analyzed within four months of collection.  相似文献   

8.
A high-performance liquid chromatographic method for the determination of phenylephrine (PE) in human serum using coulometric detection is described. PE and internal standard, orciprenaline, were extracted from serum by solid-phase extraction and separation achieved on a coupled column system consisting of two C18 cartridge columns (250×4.6 mm I.D. coupled to a shorter 50×4.6 mm I.D. column) using a mobile phase of methanol-50 mM phosphate buffer (pH 3.2; 10:90) at 36°C. Dual electrode coulometric detection was used in the “oxidative screen” mode. Calibration curves were linear over the range 0.3–4 ng/ml with a limit of quantification (LOQ) of 0.35 ng/ml. The method has a greater degree of sensitivity, precision and accuracy compared to previously published methods for PE and is suitable for use in pharmacokinetic and bioequivalence studies in humans.  相似文献   

9.
A high-performance liquid chromatographic (HPLC) achiral-chiral coupled assay to measure the serum concentration of the enantiomers of cyclophosphamide is described. The R- and S-enantiomers of cyclophosphamide were quantified using a 5-cm-long C1 Spherisorb 5-μm column, with switching of the eluent containing racemic cyclophosphamide onto a 10-cm-long α1, acid glycoprotein column. The limit of determination was 1.25 mg l−1 for each enantiomer and the ratio of the enantiomers over the range 2.5 to 100 mg l−1 was 1. Serum enantiomer concentrations in blood samples taken from patients receiving 0.30 to 0.75 g m−2 of intravenous racemic cyclophosphamide could be measured at least three half-lives post dose. In six patients no significant difference in the clearance of R- and S-cyclophosphamide was found.  相似文献   

10.
A simple HPLC method for determination of DX-9065a in human urine and feces was developed. The drug was extracted by Bond Elut CBA, a cation-exchange solid-phase extraction cartridge. The extracted drug was analyzed by HPLC with UV detection at 242 nm. With this extraction procedure, no interfering peaks were observed. The method developed was validated and showed adequate precision and accuracy. This method was applied to human clinical samples obtained from healthy Japanese volunteers who had orally received the drug. Using this method, the excretion profile of the drug in human after oral administration was revealed for the first time.  相似文献   

11.
A method is described that allows the rapid and precise determination of the local anaesthetics bupivacaine and etidocaine from biological fluids. This method uses a fully automated system with solid-phase extraction in combination with a column-switching technique. Both sample extraction on a LiChrocart pre-column and elution onto the analytical LiChrospher column, were performed automatically and concomitantly using conventional HPLC equipment in conjunction with an OSP-2 on-line sample preparator from Merck combined with UV detection. Recoveries were found to be 96.7 and 96.4% for 2 μg/ml bupivacaine and etidocaine, respectively. Lower limits of quantification were found to be 0.05 μg/ml plasma for both of the compounds.  相似文献   

12.
Ambroxol has been determined in biological fluids using a rapid and sensitive high-performance liquid chromatographic method. The samples prepared from plasma by liquid—liquid extraction were analysed on reversed-phase silica gel by competing-ion chromatography with ultraviolet detection. The method was applied to the determination of ambroxol levels in twelve healthy volunteers after oral administration of 90 mg of ambroxol in tablets of Mucosolvan and Ambrosan.  相似文献   

13.
14.
Tramadol has been determined in human plasma samples using a sensitive high-performance liquid chromatographic method. The plasma samples were extracted with tert.-butylmethyl ether in one-step liquid-liquid extraction (recovery 86%) and analyses of the extracts were performed on reversed-phase silica gel using ion-pair chromatography (verapamil as an internal standard) and fluorescence detection. The method was applied to the determination of tramadol levels in twelve healthy volunteers after oral administration of 100 mg of tramadol in capsules of Protradon and Tramal.  相似文献   

15.
A column-switching high-performance liquid chromatographic method for the simultaneous determination of five frequently prescribed benzodiazepines: clonazepam, diazepam, flunitrazepam, midazolam and oxazepam was developed. A 50-μl plasma sample was directly injected into a BioTrap 500 MS (hydrophobic polymer) column. After a washing step with a mixture of phosphate buffer and acetonitrile, the retained benzodiazepines were back-flushed into a reversed-phase (LiChrospher Select B C8) column with a mobile phase of acetonitrile–phosphate buffer. The method showed excellent linearity from 50 to 1000 ng/ml for clonazepam, flunitrazepam and midazolam and from 50 to 5000 ng/ml for diazepam and oxazepam. The recoveries were around 98% for all the benzodiazepines studied. The relative standard deviation for between- and within-day assay was <20% for low concentrations close to the values of the limit of quantification and <4% for high concentrations. The procedure described is relatively simple and rapid because no off-line manipulation of the sample is required: the total analysis time is approximately 30 min.  相似文献   

16.
17.
A selective and sensitive method for the determination of gentamicin in plasma and urine by high-performance liquid chromatography has been developed. Following deproteinization, the gentamicin is reacted with fluorescamine to produce a fluorescent derivative. This reaction mixture is directly chromatographed on a cation-exchange column using as mobile phase acetonitrile—phosphoric acid (7:3). The gentamicin components elute as a single peak. Using 0.1 ml of plasma, quantitation of gentamicin concentrations as low as 1 mg/l are possible. Possible interference from other aminoglycosides and antibiotics is discussed.  相似文献   

18.
A high-performance liquid chromatography (HPLC) method is described for the measurement of the weak alkylating agent CB1954 in human plasma. CB1954 can be used as an innocuous prodrug designed for activation by bacterial nitroreductases in strategies of gene-directed enzyme–prodrug therapy, and becomes activated to a potent bifunctional alkylating agent. The HPLC method involves precipitation and solvent extraction and uses Mitomycin C (MMC) as an internal standard, with a retention time for MMC of 5.85±0.015 min, and for CB1954 of 10.72±0.063 min. The limit of detection for CB1954 is 2.9 ng/ml, and this compares favourably with systems involving direct analysis of plasma (limit of detection 600 ng/ml, approximately). The method is now being used for pharmacokinetic measurements in plasma samples from cancer patients entering phase I clinical trials of CB1954. Results using serial plasma samples from one patient are presented. The patient was treated intravenously with CB1954 (6 mg/m2), and plasma clearance of the drug showed biphasic kinetics with α half-life 14.6 min, and β half-life 170.5 min.  相似文献   

19.
An accurate and sensitive high-performance liquid chromatographic method with UV detection was developed for the simultaneous measurement of monoethylglycinexylidide (MEGX) and lignocaine in human plasma and serum, using organic solvent extraction and trimethoprim (TMP) as an internal standard. The mean recoveries for MEGX, TMP and lignocaine were 86.1 ± 3.7, 98.3 ± 1.8 and 77.0 ± 4.7%, respectively (n = 6). The relative standard deviations for MEGX concentrations of 10 and 200 ng/ml were < 4% and for lignocaine concentrations of 200 and 1200 ng/ml they were < 8%.  相似文献   

20.
This paper reports a two-step high-performance liquid chromatographic procedure which permits the study of the incorporation of [3H]leucine into insulin in biological systems. The first step of the procedure was size exclusion chromatography, performed on a GPC-100 column, which was eluted with 0.1 M KH2PO4—methanol (9:1, v/v). By this step the bulk of both protein and radioactivity was separated from tritiated insulin. The second step, which employs reversed-phase chromatography on an octadecylsilyl column, permits the separation of insulin from other contaminants by means of a linear gradient of acetonitrile. This simple and reproducible method was employed to test insulin synthesis in cultured human retinoblastoma Y79 cells.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号