首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
A sensitive and stereospecific method for the quantitation of trimipramine enantiomers in human serum was developed. The assay involves the use of a novel mixed-mode disc solid-phase extraction for serum sample clean-up prior to HPLC analysis and is also free of interference from the enantiomers of desmethyltrimipramine, 2-hydroxytrimipramine, and 2-hydroxydesmethyltrimipramine, the three major metabolites of trimipramine. Chromatographic resolution of trimipramine enantiomers was performed on a reversed-phase cellulose-based chiral column (Chiralcel OD-R) under isocratic conditions using a mobile phase consisting of 0.3 M aqueous sodium perchlorate-acetonitrile (58:42, v/v) at a flow-rate of 0.5 ml/min. Recoveries for R- and S-trimipramine enantiomers were in the range of 93–96% at 25–185 ng/ml levels. Intra-day and inter-day precisions calculated as R.S.D. were in the ranges of 0.30-8.00% and 1.60-10.20% for both enantiomers, respectively. Intra-day and inter-day accuracies calculated as percent error were in the 0.01–2.10% and 1.00–3.00% ranges for both enantiomers, respectively. Linear calibration curves were in the concentration range 15–250 ng/ml for each enantiomer in serum. The limit of quantification of each enantiomer was 15 ng/ml. The detection limit for each enantiomer in serum using a UV detector set at 210 nm was 10 ng/ml (S/N =2). In addition, separation of the enantiomers of desmethyltrimipramine, 2-hydroxytrimipramine, and 2-hydroxydesmethyltrimipramine were investigated. The desmethyltrimipramine enantiomers could be resolved on the Chiralcel OD-R column under the same chromatographic conditions as the trimipramine enantiomers, but the other two metabolite enantiomers required different mobile phases on the Chiralcel OD-R column to achieve satisfactory resolution with Rs values of 1.00.  相似文献   

2.
High-performance liquid chromatographic methods were developed for the separation of the enantiomers of 12 beta-lactams. Direct separations were performed on chiral stationary phases (CSPs) containing cellulose-tris-3,5-dimethylphenyl carbamate (Chiralcel OD-RH and OD-H columns), the macrocyclic glycopeptide antibiotic teicoplanin (Chirobiotic T column), or teicoplanin aglycone (Chirobiotic TAG column) as the chiral selector. It was clearly established that, with teicoplanin-based columns, the teicoplanin aglycone was most often responsible for the enantioseparation of the beta-lactams. The difference in enantioselective free energy between the aglycone CSP and the teicoplanin CSP was in the range between 0.02 and 0.97 kJ mol(-1) for these beta-lactam stereoisomer separations. The separations were carried out with high selectivity and resolution, and the method was therefore suitable for monitoring of the enantiomeric excess after chiral synthesis. The Chirobiotic and Chiralcel columns appear to be highly complementary to one another. The best separation of this class of beta-lactam compound could be obtained using the Chirobiotic TAG in the polar-organic mode plus the Chiralcel OD-H in the normal-phase mode. The elution sequence was also determined.  相似文献   

3.
We describe the preparation of racemic N,N-dimethyl-3-(naphthalen-2-yl)-butan-1-amines, potential sigma1 ligands, and their resolution via chiral HPLC. In order to obtain enantiopure compounds, direct chromatographic methods of separation using chiral stationary phases were investigated. Different methods suitable for both analytical and semipreparative purposes are proposed. The best resolutions were achieved using cellulose tris (3,5-dimethylphenyl carbamate) (Chiralcel OD and OD-H) and amylose tris (3,5-dimethylphenyl carbamate) (Chiralpak AD). On the basis of the preliminary chromatographic results, the resolution of compound 1 was transferred onto a Chiralcel OD semipreparative column. The enantiomers were obtained in high enantiomeric excess. The configurational assignment was performed by circular dichroism. Computational analysis was used to explore the enantioselective recognition process of compound 1 with the Chiralcel OD stationary phase.  相似文献   

4.
A sensitive and automated method for the separation and individual determination of tramadol enantiomers in plasma has been developed using solid-phase extraction (SPE) on disposable extraction cartridges (DECs) in combination with chiral liquid chromatography (LC). The SPE operations were performed automatically by means of a sample processor equipped with a robotic arm (ASPEC system). The DEC filled with ethyl silica (50 mg) was first conditioned with methanol and phosphate buffer, pH 7.4 A 1.0-ml volume of plasma was then applied on the DEC. The washing step was performed with the same buffer. The analytes were eluted with 0.15 ml of methanol, and 0.35 ml of phosphate buffer, pH 6.0, containing sodium perchlorate (0.2 M) were added to the extract before injection into the LC system. The enantiomeric separation of tramadol was achieved using a Chiralcel OD-R column containing cellulose tris-(3,5-dimethylphenylcarbamate) as chiral stationary phase. The mobile phase was a mixture of phosphate buffer, pH 6.0, containing sodium perchlorate (0.2 M) and acetonitrile (75:25). The mobile-phase pH and the NaClO4 concentration were optimized with respect to enantiomeric resolution. The method developed was validated. Recoveries for both enantiomers of tramadol were about 100%. The method was found to be linear in the 2.5–150 ng/ml concentration range [r2=0.999 for (+)- and (−)-tramadol]. The repeatability and intermediate precision at a concentration of 50 ng/ml were 6.5 and 8.7% for (+)-tramadol and 6.1 and 7.6% for (−)-tramadol, respectively.  相似文献   

5.
Midodrine hydrochloride is a peripheral alpha(1)-adrenoreceptor agonist that induces venous and arterial vasoconstriction. Midodrine, after oral or intravenous administration, undergoes enzymatic hydrolysis and releases deglymidodrine, a pharmacologically active metabolite. Midodrine and deglymidodrine have a chiral carbon in the 2-position. To investigate the bioactivity of racemates and enantiomers of the drug and metabolite, three chromatographic chiral stationary phases, Chiralcel OD-H, Chiralcel OD-R, and alpha(1)-AGP, were evaluated for enantiomeric resolution. Good enantioseparation of midodrine racemate was obtained using the Chiralcel OD-H column. This stationary phase was then used to collect separately the midodrine enantiomers. By alkaline hydrolysis of rac-midodrine and each separated enantiomer, rac-deglymidodrine and its enantiomers were prepared. The control of the enantiomeric purity was carried out by alpha(1)-AGP stationary phase, while the hydrolysis of rac-midodrine and its enantiomers was controlled by capillary electrophoresis using trimethyl-beta-cyclodextrin as chiral selector. The pharmacological activity of the two racemates and the two enantiomeric pairs was tested in vitro on a strip of rabbit descending thoracic aorta. The tests continued that the activity of the drug and metabolite is due only to the (-)-enantiomer because neither of the (+)-enantiomers is active.  相似文献   

6.
We present a method for the enantioselective analysis of propafenone in human plasma for application in clinical pharmacokinetic studies. Propafenone enantiomers were resolved on a 10-μm Chiralcel OD-R column (250×4.6 mm I.D.) after solid-phase extraction using disposable solid-phase extraction tubes (RP-18). The mobile phase used for the resolution of propafenone enantiomers and the internal standard propranolol was 0.25 M sodium perchlorate (pH 4.0)–acetonitrile (60:40, v/v), at a flow-rate of 0.7 ml/min. The method showed a mean recovery of 99.9% for (S)-propafenone and 100.5% for (R)-propafenone, and the coefficients of variation obtained in the precision and accuracy study were below 10%. The proposed method presented quantitation limits of 25 ng/ml and was linear up to a concentration of 5000 ng/ml of each enantiomer.  相似文献   

7.
Lin K  Xu C  Zhou S  Liu W  Gan J 《Chirality》2007,19(3):171-178
Chiral high-performance liquid chromatography (HPLC) is one of the most powerful tools to prepare enantiopure standards of chiral compounds. In this study, the enantiomeric separation of imidazolinone herbicides, i.e., imazethapyr, imazapyr, and imazaquin, was investigated using chiral HPLC. The enantioselectivity of Chiralpak AS, Chiralpak AD, Chiralcel OD, and Chiralcel OJ columns for the three analytes was compared under similar chromatographic conditions. Chiralcel OJ column showed the best chiral resolving capacity among the test columns. The resolved enantiomers were distinguished by their signs of circular dichroism detected at 275 nm and their structures confirmed with LC-mass spectrometric analysis. Factors affecting the chiral separation of imidazolinones on Chiralcel OJ column were characterized. Ethanol acted as a better polar modifier than the other alcohols including 2-propanol, 1-butanol, and 1-pentanol. Although the acidic modifier in the mobile phase did not influence chiral recognition, it was necessary for reducing the retention time of enantiomers and suppressing their peak tailing. Thermodynamic evaluation suggests that enantiomeric separation of imidazolinones on Chiralcel OJ column is an enthalpy-driven process from 10 to 40 degrees C. This study also shows that small amounts of pure enantiomers of imidazolinones may be obtained by using the analytical chiral HPLC approach.  相似文献   

8.
Three types of chiral stationary phase were used to achieve chromatographic resolution of enantiomers of rac-11-dihydrooracin (DHO), the principal metabolite of a potential cytostatic drug oracin. Chiralcel OD-R as a chiral stationary phase with mobile phase comprising acetonitrile (modifier) and sodium perchlorate (buffering component) proved to be the most suitable system. Chemometric optimisation based on the Box-Wilson central composite design was employed to find the optimum resolution. The optimum factor space was defined by three parameters: temperature, modifier concentration and buffer concentration. Newly designed chromatographic response functions based on a combination of resolution R(S) and retention time of the last component eluted t(RL) were employed to evaluate the resolution with regard to quality and quantity. Optimum values predicted from those models of response surfaces were in excellent agreement with the experimental results. The chromatographic resolution of DHO enantiomers is suitable for xenobiochemical studies on stereoselectivity and stereospecificity of biotransformation enzymes.  相似文献   

9.
The chiral resolution of seven aromatase inhibitors (four triazole derivatives (Ia, Ib, Ic, and Id) and three tetrazole derivatives (IIa, IIb, and IIc)) was achieved on Chiralcel OJ-R [cellulose tris (4-methyl benzoate)], Chiralcel OD-RH [cellulose tris (3,5-dimethylphenyl carbamate)], and Chiralpak AD-RH [amylose tris (3,5-dimethylphenyl carbamate)] chiral stationary phases. The mobile phases used were A: 2-PrOH-MeCN (90:10, v/v); B: 2-PrOH-MeCN (50:50, v/v); C: MeCN-H(2)O (50:50, v/v); D: MeCN-H(2)O (80:20, v/v); and E: MeCN-H(2)O (95:05, v/v). The flow rate was 0.5 mL/min for all the mobile phases. The resolution capability of these chiral stationary phases were in the order Chiralpak AD-RH > Chiralcel OD-RH > Chiralcel OJ-R. The values of alpha and Rs of the resolved enantiomers of the aromatase inhibitors varied from 1.02-5.63 and 1. 12-6.72, respectively.  相似文献   

10.
This contribution deals with comparative studies on the chiral separation of thiazide diuretics using cellulose tris(3,5-dimethylphenylcarbamate) (Chiralcel OD-RH), cellulose tris(4-methylbenzoate) (Chiralcel OJ-R) and teicoplanin (Chirobiotic T) phases. All columns showed good chiral recognition ability for this class of compounds. Out of seven compounds investigated, six were resolved with baseline resolution with at least one of the three columns.  相似文献   

11.
Li L  Zhou S  Zhao M  Zhang A  Peng H  Tan X  Lin C  He H 《Chirality》2008,20(2):130-138
A series of organophosphorous compounds (OPs), 1-(substituted phenoxyacetoxy)alkylphosphonates containing a chiral carbon atom, show notable herbicidal activities. In this study, the enantioselective separation and biological toxicity of all these compounds were investigated. The enantioselective separation on the columns of Chiralpak AD, Chiralpak AS, Chiralcel OD, and Chiralcel OJ were compared under various chromatographic conditions. All the analytes investigated obtained baseline resolution (R(s) > 1.5) on Chiralpak AD column, which showed best chiral separation capacity. Further investigation was carried out on Chiralpak AD to evaluate the influence of the mobile phase composition and column temperature. The effect of the structural features on discrimination was also examined. The resolved enantiomers were distinguished by their signs of circular dichroism. The acute aquatic toxicity of enantiomers and racemate to Daphnia magna (D. magna) were assessed. The in vivo assays showed that compound 3 was about 2-148.5 times more toxic than the other four analogues to D. magna. The racemates of compounds 3 and 5 showed intermediate toxicity compare to their enantiomers, while those of compounds 1, 2, and 4 showed synergistic or antagonistic effect. These results suggest that the biological toxicity of chiral OPs to nontarget organisms is enantioselective and therefore should be evaluated with their pure enantiomers.  相似文献   

12.
An analytical method for the enantioselective determination of selfotel in human urine has been developed and validated. The method is based on high-performance liquid chromatography and utilizes CGS 20005 (a selfotel analog) as the internal standard. Urine samples were derivatized in situ with o-phthalic dicarboxaldehyde–3-mercaptopropionic acid and 9-fluorenylmethyl chloroformate (FMOC). Chromatographic separations of the FMOC derivatives of selfotel enantiomers and the internal standard were achieved using a column switching system consisting of an Inertsil ODS-2 column (75×4.6 mm I.D., 5 μm) and a Chiralcel OD-R column (250×4.6 mm I.D., 10 μm). The composition of the mobile phase was acetonitrile–0.1 M phosphate buffer, pH 2.50 (35:65) for the Inertsil ODS-2 column and acetonitrile–0.1 M phosphate buffer, pH 2.00 (35:65) for the Chiralcel OD-R column. The analytes were monitored using fluorescence detection at an excitation wavelength of 262 nm and an emission wavelength of 314 nm. The limit of quantification (LOQ) for this method is 0.25 μg/ml for each selfotel enantiomer. The method was successfully utilized to determine preliminary selfotel stereospecific pharmacokinetics.  相似文献   

13.
Pyriproxyfen is a chiral insecticide, and over 10 metabolites have been identified in the environment. In this work the separations of the enantiomers of pyriproxyfen and its six chiral metabolites were studied by high‐performance liquid chromatography (HPLC). Both normal phase and reverse phase were applied using the chiral columns Chiralpak IA, Chiralpak IB, Chiralpak IC, Chiralcel OD, Chiralcel OD‐RH, Chiralpak AY‐H, Chiralpak AD‐H, Chiracel OJ‐H, (R,R)‐Whelk‐O 1, and Lux Cellulose‐3. The effects of the chromatographic parameters such as mobile phase composition and temperature on the separations were investigated and the enantiomers were identified with an optical rotation detector. The enantiomers of these targets could obtain complete separations (resolution factor Rs > 1.5) on Chiralpak IA, Chiralpak IB, Chiralcel OD, Chiralpak AY‐H, or Chiracel OJ‐H under normal conditions. Chiralcel OJ‐H showed the best chiral separation results with n‐hexane as mobile phase and isopropanol (IPA) as modifier. The simultaneous enantiomeric separation of pyriproxyfen and four chiral metabolites was achieved on Chiralcel OJ‐H under optimized condition: n‐hexane/isopropanol = 80/20, 15°C, flow rate of 0.8 ml/min, and UV detection at 230 nm. The enantiomers of pyriproxyfen and the metabolites A , C , and D obtained complete separations on Chiralpak IA, Chiralpak IC, and Lux Cellulose‐3 under reverse phase using acetonitrile/water as the mobile phase. The retention factors (k) and selectivity factors (α) decreased with increasing temperature, and the separations were better under low temperature in most cases. The work is of significance for the investigation of the environmental behaviors of pyriproxyfen on an enantiomeric level. Chirality 28:245–252, 2016. © 2016 Wiley Periodicals, Inc.  相似文献   

14.
A sensitive HPLC method for the quantification of praziquantel enantiomers in human serum is described. The method involves the use of a novel disc solid-phase extraction for sample clean-up prior to HPLC analysis and is also free of interference from trans-4-hydroxypraziquantel, the major metabolite of praziquantel. Chromatographic resolution of the enantiomers was performed on a reversed-phase cellulose-based chiral column (Chiralcel OJ-R) under isocratic conditions using a mobile phase consisting of 0.1 M sodium perchlorate–acetonitrile (66:34, v/v) at a flow-rate of 0.5 ml/min. Recoveries for R-(−)- and S-(+)-praziquantel enantiomers were in the range of 84–89% at 50–500 ng/ml levels. Intra-day and inter-day precisions calculated as R.S.D. were in the ranges of 3–8% and 1–8% for both enantiomers, respectively. Intra-day and inter-day accuracies calculated as percent error were in the 0.2–5% and 0.3–8% ranges for both enantiomers, respectively. Linear calibration curves were in the concentration range 10–600 ng/ml for each enantiomer in serum. The limit of quantification of each enantiomer was 10 ng/ml. The detection limit for each enantiomer in serum using a UV detector set at 210 nm was 5 ng/ml (S/N=2).  相似文献   

15.
Patti A  Pedotti S  Sanfilippo C 《Chirality》2007,19(5):344-351
The direct HPLC enantiomeric separation of several ferrocenylalcohols on the commercially available Chiralcel OD and Chiralcel OJ columns has been evaluated in normal-phase mode. Almost all the compounds were resolved on one or both chiral stationary phases (CSPs) with separation factor (alpha) ranging from 1.06 to 2.88 while the resolution (R(s)) varied from 0.63 to 12.70 In the separation of the alpha-ferrocenylalcohols 1a-e and the phenyl analogues 2a-e, which were all resolved except 1c, a similar trend in the retention behavior for the two series of alcohols was evidenced and the selectivity was roughly complementary on the two investigated CSP. For three ferrocenylacohols, chosen as model compounds, the influence of the mobile phase composition and temperature on the enantioseparation were investigated and additional information on the chiral recognition mechanism were deduced from the chromatographic behavior of their acetylderivatives.  相似文献   

16.
《Chirality》2017,29(12):847-853
Kinetic resolution of (R ,S )‐atenolol is a faster strategy to produce (S )‐atenolol. Since this racemate is a less soluble compound, resolution of its ester offers high concentrations in the process. A good analytical method is required to observe the enantiomer concentrations. This paper described application of ultra‐fast liquid chromatography on the atenolol ester separation using different resolution media and analytical procedures. Chiralcel OD column resolved the ester. The chromatograms indicated different characteristics of the process. The enantiomers could be recognized by the column in less than 1 (one) hour. Symmetrical peaks were obtained, but several procedures produced peaks with wide bases and slanted baselines. Efficient enantioresolution was obtained at high mobile phase flow rate, decreased concentration of amine‐type modifier, but increased alcohol content in the mobile phase. High UV detection wavelength was required. At 1.0 mL/min, the (90/10/0.5) composition resulted α  = 1.46 and R S  = 0.9998 that were good separation.  相似文献   

17.
A stereoselective high-performance liquid chromatographic (HPLC) method is described for the selective and sensitive quantitation in human plasma of R-(+)- and S-(−)-enantiomers of remoxipride. Remoxipride was extracted from basified plasma into hexane-methyl-tert.-butyl ether (20:80, v/v), washed with sodium hydroxide (1.0 M), then back-extracted into phosphoric acid (0.1 M). A structural analog of remoxipride was used as an internal standard. The sample extracts were chromatographed using a silica-based derivatized cellulose chiral column, Chiralcel OD-R, and a reversed-phase eluent containing 30–32% acetonitrile in 0.1 M potassium hexafluorophosphate. Ultraviolet (UV) absorbance detection was performed at 214 nm. Using 0.5-ml plasma aliquots, the method was validated in the concentration range 0.02-2.0 μg/ml and was applied in the investigation of systemic inversion of remoxipride enantiomers in man.  相似文献   

18.
Enantioselective separations on chiral stationary phases with or without derivatization were developed and compared for the HPLC analysis of (+)-(R)- and (-)-(S)-metoprolol acidic metabolite in human plasma and urine. The enantiomers were analysed in plasma and urine without derivatization on a Chiralcel OD-R column, and in urine after derivatization using methanol in acidic medium on a Chiralcel OD-H column. The quantitation limits were 17 ng of each enantiomer/ml plasma and 0.5 microgram of each enantiomer/ml urine using both methods. The confident limits show that the methods are compatible with pharmacokinetic investigations of the enantioselective metabolism of metoprolol. The methods were employed in a metabolism study of racemic metoprolol administered to a patient phenotyped as an extensive metabolizer of debrisoquine. The enantiomeric ratio (+)-(R)/(-)-(S)-acid metabolite was 1.1 for plasma and 1.2 for urine. Clearances were 0.41 and 0.25 l/h/kg, respectively, for the (+)-(R)- and (-)-(S)-enantiomers. The correlation coefficients between the urine concentrations of the acid metabolite enantiomers obtained by the two methods were >0.99. The two methods demonstrated interchangeable application to pharmacokinetics.  相似文献   

19.
The poly(trans-1,2-cyclohexanediyl-bis acrylamide) (P-CAP) column has so far been primarily used with normal phase and polar organic mobile phase chromatography. Its use in supercritical fluid chromatography (SFC) was investigated via the analysis of 40 commercial and 100 proprietary compounds using a 12-min gradient with methanol as a modifier. Results were then compared against those obtained from the popular derivatized polysaccharide-based chiral stationary phases (CSPs) such as Chiralpak AD-H and Chiralpak AS-H as well as Chiralcel OD-H and Chiralcel OJ-H columns. P-CAP demonstrated separation of 25% of the 140 total compounds, while each of the derivatized polysaccharide-based CSPs separated at least 46%. A study that compared the loading of 1,1'-bi-2-naphthol with P-CAP and Chiralpak AS columns indicated a similar trend in resolution vs. amount injected, though AS appeared capable of allowing a greater loading of material. The P-CAP column was found to be beneficial in the separation of a complex mixture of enantiomers and achiral impurities, where the derivatized polysaccharide-based columns did not show as desirable of a separation. A key advantage of this type of chiral stationary phase is the fact that it is available in both enantiomeric forms, allowing manipulation of elution order of enantiomers, which is especially helpful for preparative applications. P-CAP also demonstrated that it could resolve an achiral impurity from the desired compound in a different mixture, while the same impurity co-eluted on the Chiralpak AD-H column. Overall, the synthetic polymer-based P-CAP showed less chiral discrimination power compared to the derivatized polysaccharide-based CSPs under the conditions explored in this study.  相似文献   

20.
Hui Liu  Wei Ding 《Chirality》2019,31(3):219-229
Prothioconazole is a type of broad‐spectrum triazole thione fungicide developed by the Bayer Company. Prothioconazole‐desthio is the main metabolite of prothioconazole in the environment. In our study, enantiomeric separation of prothioconazole and prothioconazole‐desthio was performed on various chiral stationary phases (CSPs) by high‐performance liquid chromatography (HPLC). It was found that polysaccharide CSPs showed better ability than brushing CSPs in enantiomeric separation. The successful chiral separation of prothioconazole could be achieved on self‐made Chiralcel OD, commercialized Chiralcel OJ‐H and Lux Cellulose‐1. Chiralpak IA, Chiralpak IB, Chiralpak IC, Chiralcel OD, Chiralpak AY‐H, Chiralpak AZ‐H, and Lux Cellulose‐1 realized the baseline separation of prothioconazole‐desthio enantiomers. Simultaneous enantiomeric separation of prothioconazole and prothioconazole‐desthio was performed on Lux Cellulose‐1 using acetonitrile (ACN) and water as mobile phase. In most cases, low temperature favored the separation of two compounds. The influence of the mobile phase ratio or type was deeply discussed. We obtained larger Rs and longer analysis time with a smaller proportion of isopropanol (IPA) or ethanol and more water content at the same temperature. The ratio of ACN and water had influences on the outflow orders of prothioconazole‐desthio enantiomers. This work provides a new approach for chiral separation of prothioconazole and prothioconazole‐desthio with a discussion of chiral separation mechanism on different CSPs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号