首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
For detection of antibody to bovine leukemia virus (BLV) major core protein of p24 and cross-reactive antibody in human patients infected with human T cell leukemia virus type I (HTLV-I), monoclonal antibody, D432 against BLV p24 was used by competitive binding enzyme-linked immunoadsorbed assay (ELISA). In sera from cattle with enzootic bovine leukosis (EBL) which were positive for BLV antibodies by immunodiffusion test, 109 out of 112 (97.3%) were positive for BLV p24 antibody by competitive binding ELISA. By using the same procedures, 21 samples from adult T cell leukemia (ATL) patients and healthy carriers with HTLV-I were tested for cross-reactive antibody to BLV p24. All 21 samples were positive for HTLV-I antibodies by immunofluorescence test and/or ELISA. By competitive binding ELISA using non-treated BLV antigens, none of these 21 samples inhibited the binding of the D432. When the BLV antigen was treated by several different denaturation procedures, several HTLV-I positive samples showed the inhibition of the D432 binding and the most effective treatment was by 2-mercaptoethanol (2-ME). Sixteen out of 21 samples showed the presence of cross-reactive antibody against 2-ME-treated BLV antigens. The cross-reactivity of human sample to BLV p24 antigen was further confirmed by Western blotting of the 2-ME-treated BLV antigens. None of the 28 samples from leukemia patients other than ATL which were negative for HTLV-I antibodies showed inhibition of the D432 by the competitive binding ELISA.  相似文献   

2.
Monoclonal antibodies (mAb) are not only useful reagents but also represent a promising type of therapeutics due to their high affinity and exquisite specificity for their antigens. A critical step in mAb generation is to identify antigen-specific antibodies. Although enzyme-linked immunosorbent assay (ELISA) has been broadly applied for antibody selection against secreted antigens, an inherent disadvantage for ELISA is the difficulty in identifying antibodies that recognize the native conformation of cell surface antigens. To overcome this drawback, the authors have developed a high-throughput cell-based antibody binding assay using fluorometric microvolume assay technology (FMAT). This method offers a homogeneous assay for detection of antibody binding to its antigen on the cell surface. To distinguish antibodies that bind to antigen on the cell surface from those that bind nonspecifically to cells, the binding is assessed using both antigen-expressing cells and related cells devoid of the antigen expression. This assay can detect antibodies at a concentration as low as 5 ng/mL and cell surface antigen as low as 9000 copies per cell. Results demonstrate that the FMAT method provides a sensitive and homogeneous assay to detect antibody binding to cell surface antigens and is amenable for high-throughput hybridoma selection.  相似文献   

3.
A chemiluminescent enzyme linked immunosorbent assay (ELISA) for the detection of antibody to hepatitis B virus surface antigen (anti-HBs) in human serum has been developed. Polystyrene microtitre plates were coated with recombinant, yeast-derived hepatitis B surface antigen (rec-HBsAg). Patient serum samples and appropriate controls were added to the rec-HBsAg-coated wells and incubated to bind anti-HBs. The wells were then washed and a fluorescein isothiocyanate (FITC) conjugate of a human plasma-derived hepatitis B surface antigen (HBsAg) was added. Following incubation and further washing the bound FITC-labelled HBsAg was detected after addition of a horseradish peroxidase (HRP) conjugate of a monoclonal anti-FITC antibody and assaying for the enzyme. The activity of the HRP was measured using luminol and hydrogen peroxide as substrates and iodophenol as a chemiluminescence enhancer. The luminescence was recorded using a camera luminometer. Preliminary tests have shown the assay to be suitable for the detection of antibody in sera from both vaccinees and also from individuals with a past hepatitis B virus infection. The use of the FITC-anti-FITC system together with the measurement of a chemiluminescence signal makes possible the completion of this assay in a few hours. The assay has been shown to be both specific and sensitive and provides a permanent photographic record.  相似文献   

4.
目的 酶联免疫吸附测定(ELISA)被广泛用于抗体或抗原的检测,并被视为临床实践中的金标准,可提供相对可靠、灵敏和特异的检测结果.ELISA的本质是抗原与相应抗体之间的特异性相互作用.然而,天然抗体固有的不稳定性是ELISA的一个难以克服的弱点,并可能导致检测结果的重现性差甚至错误的诊断结果.本课题组先前应用构象工程方...  相似文献   

5.
Twenty-one monoclonal antibodies were produced against promastigote antigens of Leishmania donovani. Five monoclonal antibodies (Hyb.17, 6, 5, 4 and 2) identifying molecules associated with various L. donovani antigenic determinants ranging from 42-116 kDa were selected as 'capture antibodies' and compared with specific anti-leishmania antisera for detection of circulating leishmania antigens in kala azar patients' sera in a competitive-enzyme-linked immunosorbent assay system (ELISA). The anti-leishmania antisera could detect circulating antigen in 30% of kala azar cases while out of the five monoclonals, Hyb.17 could effectively detect circulating leishmania antigen in 85.4%. The efficacy of Hyb.6 was however low (31.7%). The antigens recognized by these monoclonal antibodies in the western blot assay could possibly represent the ones circulating in sera of patients suffering from kala azar. A cocktail of these monoclonal antibodies may be more useful than the conventional polyclonal antisera in detection of circulating antigen for clinical diagnosis of kala azar.  相似文献   

6.
Buffers of different pH and ionic strength were employed as coating buffers for antigen adsorption to microtitre plates. Their efficiency for coating plates with rinderpest virus (RPV) and foot-and-mouth disease virus (FMDV) antigens was studied by ELISA with polyclonal and monoclonal antibody preparations. While the adsorption and detection of RPV antigen with polyclonal antiserum was highly dependent on the ionic strength and pH of coating buffer, adsorption of antigenically active FMDV antigen was relatively unaffected by the buffering conditions. Both antigens were adsorbed optimally in 0.01 M phosphate buffer, pH 8.0. When monoclonal antibodies were used to detect antigen, there was a greater degree of dependence on the coating buffer than that found with polyclonal antisera. Moreover, when they were used to detect antigen adsorbed under several buffering conditions, monoclonal antibodies showed a variety of preferred buffers. The usefulness of this differential reactivity in distinguishing epitope specificity is demonstrated.  相似文献   

7.
A method for studies of an El Tor-associated antigen of Vibrio cholerae O1   总被引:1,自引:0,他引:1  
A method for studying the biotype El Tor associated mannose-sensitive haemagglutinin (MSHA) of V. cholerae O1 has been developed. By using crude MSHA adsorbed to chicken erythrocytes as solid phase antigen in an enzyme-linked immunosorbent assay (ELISA), antisera against V. cholerae of the El Tor biotype reacted in high titre with the MSHA-coated cells, whereas antisera against vibrios of the classical biotype did not bind significantly, i.e. in higher titre than pre-immune sera. The binding of anti-MSHA serum, or a monoclonal antibody against MSHA, to the MSHA-coated erythrocytes could be efficiently inhibited by crude MSHA as well as by El Tor vibrios whereas neither V. cholerae lipopolysaccharide nor different strains of classical vibrios had any inhibitory effect. These results support the existence of an El Tor-associated immunogen. They also suggest a possibility of determining antibodies against different haemagglutinins in ELISA without having access to purified antigens.  相似文献   

8.
A competitive indirect chemiluminescence enzyme immunoassay (ic-CLEIA) for chloramphenicol (CAP) residues in shrimp has been developed. After optimization (incubation time, concentration of Tween-20, concentration of PBS and pH), the method gave a limit of detection of 0.01 ng/mL and a detection range of 0.03-23.7 ng/mL, with an ED(50) of 0.47 ng/mL. The method has been validated on spiked shrimp samples in terms of precision (intra- and interassay coefficient variations of less than 10% and 15%, respectively) and accuracy (mean recovery 95-123%). The assay performance is better than the ELISA method which is widely used to detect chloramphenicol and indicates that the CLEIA method can be used to test aquatic samples instead of ELISA.  相似文献   

9.
The enzyme-linked immunosorbant assay (ELISA) is a rapid, high-throughput, quantitative immunoassay for the selective detection of target antigens. The general principle behind an ELISA is antibody mediated capture and detection of an antigen with a measurable substrate. Numerous incarnations of the ELISA have resulted in its commercialization for sensitive diagnostic applications using a variety of detection platforms. Many of these applications require a pair of antibodies necessary for the capture and detection of a specific antigen (cELISA) in defined substrates. However, the availability of cELISA for target antigens is limited and thus restricts the use of this technique for quantitative measure of antigens during discovery. Alternatively, the indirect ELISA (iELISA) requires only a single antibody directed against a target antigen that has been immobilized to a surface. Unlike the cELISA, which uses an immobilized capture antibody that can bind a native antigen in solution followed by a detector antibody that binds captured antigen, the iELISA uses an antibody the binds directly to an immobilized antigen for detection. Although the iELISA may lack the sensitivity of a cELISA, its requirement of only a single antigen specific antibody makes it a simple technique for evaluating the relative difference in the level of target protein expression between samples. However, many antibodies that work effectively to detect protein antigens in other immunoassays such as Western blotting or immunohistochemistry fail to work in microplate based iELISA. Although these alternate immunoassay methods are useful for qualitative determination of target antigens, they provide limited quantitative information, limiting the assessment of sample specific differences in protein expression. We hypothesized that protein conformation following adsorption on the plastic surface of microplates impedes antibody epitope binding and this restriction could be overcome by a short chemical denaturation step. In this report we define a rapid method to assess the utility of an antibody for iELISA application and demonstrate a significant improvement in both qualitative and quantitative protein detection after chemical denaturation using defined assay conditions.  相似文献   

10.
目的酶联免疫吸附测定(ELISA)被广泛用于抗体或抗原的检测,并被视为临床实践中的金标准,可提供相对可靠、灵敏和特异的检测结果。ELISA的本质是抗原与相应抗体之间的特异性相互作用。然而,天然抗体固有的不稳定性是ELISA的一个难以克服的弱点,并可能导致检测结果的重现性差甚至错误的诊断结果。本课题组先前应用构象工程方法开发了一种基于金纳米粒子的人工抗体(简称金抗体)。金抗体可以像天然抗体一样特异性地与抗原相互作用,并且具备远优于天然抗体的稳定性。出色的稳定性使金抗体可能成为天然抗体更好的替代物,用于ELISA中。方法经过必要的优化并与辣根过氧化物酶(HRP)耦联后,制得酶标金抗体10HRP-(Au-400P1),然后用酶标金抗体代替天然酶标抗体用于ELISA检测中。结果通过一系列的实验证明,抗溶菌酶金抗体可用于ELISA特异性检测1~16 mg/L范围内的鸡蛋清溶菌酶(HEWL)样品。结论金抗体可以替代天然抗体用于ELISA检测,并具有优于传统ELISA法的检测准确性和一致性。  相似文献   

11.
ELISA "sandwich" techniques have been developed and the optimum assay conditions for detecting specific antibodies in human serum samples have been determined. The possibility of using these techniques for the determination of the level of antibodies to tularemia antigens in the sera of persons immunized with live tularemia vaccine has been shown. Statistically significant differences in the level of antibodies to tularemia antigen in the sera of immunized and nonimmunized persons have been established. The comparative study of five serological methods - ELISA, the agglutination test, the passive hemagglutination test, the immunofluorescence test and the defined antigen substrate sera ( DASS ) techniques - has revealed the advantage of ELISA, whose sensitivity has proved to be considerably higher than that of all other methods used in our work.  相似文献   

12.
A Schistosoma mansoni cercarial antigen preparation (cercarial transformation fluid – SmCTF) was evaluated for detection of anti-schistosome antibodies in human sera in 4 collaborating laboratories. The performance of SmCTF was compared with that of S. mansoni egg antigens (SmSEA) in an indirect enzyme-immunoassay (ELISA) antigen assay, the latter being used routinely in 3 of the 4 participating laboratories to diagnose S. mansoni and S. haematobium infections. In the fourth laboratory the performance of SmCTF was compared with that of S. japonicum egg antigens (SjSEA) in ELISA for detection of anti-S. japonicum antibodies. In all 4 laboratories the results given by SmCTF in ELISA were very similar to those given by the antigen preparation routinely used in the respective laboratory to detect anti-schistosome antibodies in human infection sera. In so far as the ELISA results from SmCTF are thus so little different from those given by schistosome egg antigens and also cheaper to produce, the former is a potentially useful new diagnostic aid for schistosomiasis.  相似文献   

13.
The surface antigens of the bovine filarial parasite Setaria digitata were isolated by EDTA extraction and purified by affinity chromatography using sepharose bound human filarial (Wuchereria bancrofti) antibodies obtained from chronic human filarial sera. The purified and crude antigens were used in enzyme-linked immunosorbent assay (ELISA) for the detection of serum antibodies in bancroftian filariasis. The purified antigen showed sensitive and specific reactions in ELISA for the detection of antibodies in filarial sera and showed least cross reactivity with other parasitic infections. The crude and purified antigens showed about 18 and 6 peptide bands respectively in SDS-PAGE and about 11 and 6 antigenic bands respectively in enzyme-linked immunoelectrotransfer blot (EITB). The purified antigen was observed to be glycoprotein in nature. It was possible to identify the stage-specific infection in human filariasis by using the crude and purified antigens in EITB.  相似文献   

14.
The aim of this study was to use larval, parasitic female and egg antigens from Strongyloides venezuelensis to detect parasite-specific IgG and immune complexes in human serum samples by enzyme-linked immunosorbent assay (ELISA). In total, 95 serum samples were analysed, consisting of 30 patients harbouring S. stercoralis larvae, 30 healthy subjects and 35 patients with other parasites. Sensitivity, specificity and diagnostic efficiency were calculated. A significant statistical difference was found in the detection of immune complexes and antibodies in patients harbouring S. stercoralis larvae from larval and eggs antigens, with higher positivity using larval antigen. The larval antigen showed the highest values for sensitivity, specificity and diagnostic efficiency in ELISA from detection of immune complexes. For the first time we used IgG anti-larvae, IgG anti-parasitic females or IgG anti-eggs for immune complex detection. We concluded that the association of antibody and immune complex detection could be used in the diagnosis of human strongyloidiasis.  相似文献   

15.
A new method for lowering the detection limit for a horseradish peroxidase (HRP) label in an enzyme-linked immunosorbent assay (ELISA) is proposed. The method is based on the use of a photochemical reaction of o-phenylenediamine (o-PD) autosensitized oxidation as an enhancement step in ELISA. The assay consists of two successive steps. The first step is a conventional HRP-mediated ELISA, using high-purity o-PD as a substrate. At this step, an o-PD oxidation product, 2,3-diaminophenazine (DAP), is formed in the dark. At the second step, the sample is illuminated at 400-500 nm for several minutes. Under illumination the concentration of DAP is greatly increased, depending on the duration and intensity of irradiation. Providing that the irradiation conditions are standardized, the final DAP concentration is proportional to the concentration of DAP formed by HRP. An ELISA for human carcinoembryonic antigen has demonstrated that the photochemical amplification method allows the detection limit of an assayed antigen to be lowered and the consumption of antibodies to be reduced. At the second step of this assay, the DAP concentration has been increased 50-fold under 4 min of irradiation.  相似文献   

16.
Abstract An enzyme-linked immunosorbent assay (ELISA) has been developed to measure antibody levels in human sera to a candidate vaccine antigen, merozoite surface protein-1 (MSP1), of the malaria parasite Plasmodium falciparum . To ensure the detection of antibodies reactive with important conformational epitopes, antigens used in the ELISA were obtained from either in vitro parasite cultures, or from a baculovirus expression system in which correct folding of recombinant MSP1-derived polypeptides has been previously demonstrated. The specificity of the ELISA was confirmed using a novel antibody affinity select method. The assay was used to investigate the pattern of acquisition of anti-MSP1 antibodies in a cross-sectional survey of 387 3–8 year old residents of a malaria endemic area of the Gambia. A significant positive correlation between anti-MSP1 antibody levels and age was evident, though individual responses to two antigens corresponding to two distinct domains of the MSP1 varied widely.  相似文献   

17.
A novel method of micro-plate magnetic chemiluminescence enzyme immunoassay (MMCLEIA) for the screening of 17beta-estradiol in water samples was proposed. It used the micro-plate magnetic separator designed by ourselves which can achieve the high-throughput analysis without the samples pre-treatment and the sensitive chemiluminescence system of AMPPD-ALP system. The method showed specific recognition of estrogen, without cross-reactions for three other major estrogenic compounds (17beta-estradiol (E2), estriol (E3), ethinyl (E2)) commonly found in water. The MMCLEIA was also especially suitable for the large-scale samples processing. The working range for 17beta-estradiol was 10-3000 pg/ml. The assay sensitivity was 5.4 pg/ml. Both intra- and inter-assay had relative standard deviation of less 15%. The effect of several physico-chemical parameters, such as the ratio of antibody versus antigen, incubation time and the concentration of detergent were studied. This method has been successfully applied to the preliminary detection of the sea-water. Compared with the chemiluminescence enzyme-linked immunosorbed assay, the correlation was good.  相似文献   

18.
An indirect enzyme-linked immunosorbent assay (ELISA) method based on a novel multi-epitope antigen of S protein (SE) was developed for antibodies detection against infectious bronchitis virus (IBV). The multi-epitope antigen SE protein was designed by arranging three S gene fragments (166–247 aa, S1 gene; 501–515 aa, S1 gene; 8–30 aa, S2 gene) in tandem. It was identified to be approximately 32 kDa as a His-tagged fusion protein and can bind IBV positive serum by western blot analysis. The conditions of the SE-ELISA method were optimized. The optimal concentration of the coating antigen SE was 3.689 μg/mL and the dilution of the primary antibodies was identified as 1:1000 using a checkerboard titration. The cut-off OD450 value was established at 0.332. The relative sensitivity and specificity between the SE-ELISA and IDEXX ELISA kit were 92.38 and 89.83%, respectively, with an accuracy of 91.46%. This assay is sensitive and specific for detection of antibodies against IBV.  相似文献   

19.
Sensitive fluorescent detection of protein on nylon membranes   总被引:2,自引:0,他引:2  
Detection of antigen immobilized on membranes, as in Western transfers and dot enzyme linked immunosorbent assays (ELISAs), often employ antibody-enzyme conjugates and chemiluminescent or precipitated colored reaction products. Although chemiluminescent markers are sensitive, they are time-consuming because of their required exposure to X-ray film and the presence of background artifacts sometimes limits their use. This report demonstrates that direct fluorescent detection technique using nylon membranes that has higher sensitivity than chemiluminescent methods is easier to perform and has a uniform, low background. An alkaline phosphatase conjugated antibody was compared with antibody conjugated to a fluorescent phycobiliprotein (allophycocyanin) for sensitivity in both Western transfers and dot ELISA assays using mouse IgG as the membrane-bound antigen. Direct fluorescent detection of antigen-antibody complexes on positively charged nylon membrane provided better sensitivity and lower background than similar conditions using enzyme amplification and chemiluminescent detection on either nylon or PVDF membranes. Processing time was reduced by the elimination of steps associated with substrate incubation, washing and X-ray film exposures required for chemiluminescence detection. These data support the view that direct fluorescent detection can represent a significant improvement in assay sensitivity and reduction in time compared with more traditional chemiluminescent detection techniques employed in the conduct of Western transfers and dot ELISA studies.  相似文献   

20.
Toxin production and the intensity of toxin formation in 265 C. diphtheriae strains circulating in different areas of the USSR have been studied by the method of the enzyme-linked immunosorbent assay (ELISA). This study has been carried out with the use of the assay system consisting of monoclonal antibodies to the COOH-area of the B-fragment of the toxin molecule adsorbed onto the surface of polystyrene plates, affinity-purified polyclonal antidiphtheria antibodies labeled with horse-radish peroxidase and substrate indicator mixture (5-aminosalicylic acid and hydrogen peroxide). Some specific features of using ELISA for the detection of C. diphtheriae toxin directly in liquid culture medium are presented. High sensitivity, specificity and good reproducibility of this method permitting the detection of C. diphtheriae toxin and the determination of the intensity of toxin formation in the C. diphtheriae strains under study are shown. The method may be recommended for practical use at health institutions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号