首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 23 毫秒
1.
Chemiluminescent assay for detection of viable microorganisms   总被引:3,自引:0,他引:3  
The redox reaction between quinone and viable microorganisms produces active oxygen species. In this study, the production rates of active oxygen species were determined by a luminol chemiluminescent assay, and the luminescence intensity was found to be proportional to the viable cell number. The high sensitivity of the luminol chemiluminescent assay was achieved with Mo-ethylenediaminetetraacetate complex and menadione or coenzyme Q1. The detectable cell densities of bacteria and yeasts were found to be approximately several thousand colony-forming units (CFU/ml) when assays were performed with a 96-well microplate luminometer. The chemiluminescent assay requires 10 min for incubation of quinone and microorganisms and 2s for photon counting. Single Escherichia coli was detected after 4h of cultivation and centrifugation (5 min x 2). This simple chemiluminescent assay is expected to be useful for the rapid detection of viable bacteria and yeast.  相似文献   

2.
A conventional colorimetric peroxidase end-point (ortho-phenylenediamine substrate), used in an enzyme immunoassay for carcinoembryonic antigen, employing plastic beads as solid support, has been replaced by a much faster (30 seconds versus 30 minutes) enhanced chemiluminescent assay for the peroxidase label. Para-iodophenol was used to enhance the light emission from the peroxidase catalysed chemiluminescent reaction between luminol and hydrogen peroxide. Values for precision and carcinoembryonic antigen concentration obtained with the chemiluminescent and colorimetric versions of the immunoassay on 62 serum specimens were in good agreement.  相似文献   

3.
Menadione-catalyzed H2O2 production by viable cells is proportional to viable cell number. The correlations between the viable cell number and the concentration of H2O2 produced are determined with the rapid chemiluminescent assay (S. Yamashoji, T. Ikeda, and K. Yamashoji, 1989, Anal. Biochem. 181, 149-152). This chemiluminescent assay of viable cells requires only 10 min and is much faster than NR (neutral red) inclusion and MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) reduction assays, which require 3-5 h. When viable cells are incubated with antitumor drugs, detergents, mycotoxins, and glycoalkaloids for 24-48 h, a decrease in menadione-catalyzed H2O2 production in a dose- or incubation time-dependent manner is observed. In general, the 50% inhibition concentration determined by the chemiluminescent assay is lower than that determined by NR inclusion and MTT reduction assays, and the order of relative cytotoxic effects of agents is the same among these assays. Furthermore, clear cytotoxic effects are observed by the chemiluminescent assay after 1 h exposure of trypsinized cells to toxic compounds. Therefore, the chemiluminescent assay is expected to be more useful for the rapid detection of cytotoxic compounds than NR inclusion and MTT reduction assays.  相似文献   

4.
Enhanced chemiluminescent assays for hydrolase enzymes have been developed using proehancer and pro-anti-enhancer substrates. Alkaline phosphatase is measured using disodium para-iodophenyl phosphate (proenhancer) which is converted to para-iodophenol and this in turn enhances the light emission from the horseradish peroxidase catalysed chemiluminescent oxidation of luminol by peroxide. An alternative strategy uses para-nitrophenyl phosphate which is converted by alkaline phosphatase to para-nitrophenol which inhibits the enhanced chemiluminescent reaction. The detection limit for the enzyme using the proenhancer and pro-anti-enhancer assays was 100 attomoles and 1 picornole, respectively. The proenhancer strategy was effective in assays for beta-D-galactosidase, beta-D -glucosidase and aryl sulfatase. A limited comparison of the proenhancer and a conventional colorimetric assay for an alkaline phosphatase label in an enzyme immunoassay for alpha-fetoprotein showed good agreement.  相似文献   

5.
R Créton  L F Jaffe 《BioTechniques》2001,31(5):1098-100, 1102-5
Chemiluminescence has become a standard tool in biomedical research. Chemiluminescent probes are used for immunoassays, nucleic acid identification, reporter gene assays, measuring enzyme activity, and the detection of ions and small molecules such as Ca2+, ATP, NO, O2- and H2O2. Along with the development of new chemiluminescent probes, significant progress has been made in techniques to measure chemiluminescence. Ultra-sensitive photometers or luminometers have become widely available and can be obtained with automatic injectors and microplate readers. In addition, imaging photon detectors have been developed that allow the imaging of chemiluminescence from gels, blots, and microplates. Imaging photon detectors have also been attached to microscopes and allow imaging of chemiluminescent probes and reporter genes in cells and tissues. Specific methods of photon collection, storage, and analysis have been developed for microscopic imaging of chemiluminescence. Two of these methods are discussed in detail. The first is a method of data storage that allows days of continuous imaging without creating oversized files. The second is a method for calibrating photon imaging microscopes using a low-light standard. Such calibration will be helpful for comparing the performance of various photon imaging systems and for comparing data obtained in different laboratories.  相似文献   

6.
Acetylcholine and choline chemiluminescent assays have limitations when these compounds are detected in small areas of mammalian nervous tissue. Use of 7-dimethyl-aminonaphthalene-1,2-dicarbonic acid hydrazide (7-DMAN), instead of luminol, gives a threefold increase in emitted light in the chemiluminescent assay for acetylcholine based on the coupled choline oxidase-peroxidase reaction. Addition of light enhancers, such as para-iodophenol or D-luciferin, to luminol or 7-DMAN further increased the light emission. Under these conditions the detection limit for acetylcholine was 650 femtomoles. This enhanced chemiluminescent assay should be convenient for the detection of in vivo and in vitro acetylcholine release from mammalian neurons.  相似文献   

7.
A nonsense mutation in the mouse leptin gene causes genetic obesity. As a result of extensive research in the field of obesity, the use of leptinob mice is widespread. This mutation renders mice sterile, creating the need to breed heterozygous mice. For this reason, leptinob genotyping is necessary. To date, gel-based assays have been used for genotyping. Using the Invader Plus assay for single nucleotide polymorphism (SNP) detection, we have developed a gel-free microplate SNP assay for genotyping leptinwt and leptinob alleles.  相似文献   

8.
Two rapid and simple procedures for the quantitative analysis of GDP-l-fucose (GDP-Fuc) are described. The methods are based on time-resolved fluorescence and microplate assay technology. The first assay relies on measuring the enzyme activity of alpha1, 3-fucosyltransferase. In this assay, transfer of fucose from GDP-Fuc converts sialyllactosamine to sialyl Lewis x tetrasaccharide, which is detected and quantified by relevant antibodies on a microplate. The formation of the reaction product is directly dependent on the presence of GDP-Fuc in the concentration range of 10-10,000 nM. In the second method GDP-Fuc inhibits the binding of fucose-specific Aleuria aurantia lectin to fucosylated glycan on a microwell. The lectin-based assay is less sensitive than the enzyme assay, but it is cheaper and faster. We used these assays in monitoring the amount of GDP-Fuc in crude lysates of transgenic yeast, which expresses the enzymes producing GDP-Fuc. The newly developed assays are versatile and applicable to measure also other nucleotide sugars or glycosyltransferase activities in a high-throughput manner.  相似文献   

9.
10.
Butyrylcholinesterase (BChE) activity assay and inhibitor phenotyping can help to identify patients at risk of prolonged paralysis following the administration of neuromuscular blocking agents. The assay plays an important role in clinical chemistry as a good diagnostic marker for intoxication with pesticides and nerve agents. Furthermore, the assay is also commonly used for in vitro characterization of cholinesterases, their toxins and drugs. There is still lack of standardized procedure for measurement of BChE activity and many laboratories use different substrates at various concentrations. The purpose of this study was to validate the BChE activity assay to determine the best dilution of human serum and the most optimal concentration of substrates and inhibitors. Serum BChE activity was measured using modified Ellman’s method applicable for a microplate reader. We present our experience and new insights into the protocol for high-throughput routine assays of human plasma cholinesterase activities adapted to a microplate reader. During our routine assays used for the determination of BChE activity, we have observed that serum dilution factor influences the results obtained. We show that a 400-fold dilution of serum and 5mM S-butyrylthiocholine iodide can be successfully used for the accurate measurement of BChE activity in human serum. We also discuss usage of various concentrations of dibucaine and fluoride in BChE phenotyping. This study indicates that some factors of such a multicomponent clinical material like serum can influence kinetic parameters of the BChE. The observed inhibitory effect is dependent on serum dilution factor used in the assay.  相似文献   

11.
Lactate dehydrogenase and the diagnosis of malaria   总被引:6,自引:0,他引:6  
Over the past five years, several methods have been developed that exploit the differences between Plasmodium lactate dehydrogenase (pLDH) and the human LDH isoforms for the purposes of measuring pLDH in blood and in in vitro cultures. These methods have been incorporated into an easy screening method for the identification and quantitation of parasite growth in in vitro cultures using a Malstattrade mark reagent. In addition, another quantitative microplate method, the immunocapture pLDH (IcpLDH) assay, has been developed that utilizes monoclonal antibodies (mAbs) to capture the pLDH and then to measure the captured enzyme by its ability to reduce 3 acetyl pyridine adenine dinucleotide (APAD). In addition, a rapid immunochromatographic method, the OptiMAL(R) assay, has been formatted to capture pLDH as an antigen, and then to signal the presence of this captured antigen (enzyme) with a colloid conjugated antibody. The microplate IcpLDH assay, and the dipstick OptiMAL(R) assays, are both being used for the diagnosis and monitoring of malaria infections, as described here by Michael Makler, Rob Piper and Wil Milhous.  相似文献   

12.
Because of the vasoactive properties of thromboxane A2 and other related prostaglandins, much research has been conducted on drugs which alter their levels. Urinary levels of thromboxane B2 and 2,3-dinor thromboxane B2 (major urinary metabolite of thromboxane B2) are used as an indication of thromboxane production in-vivo. In order to accurately measure urinary TXB2 levels of subjects on investigative drugs which lower TXA2 and subsequently TXB2, a simple and sensitive analytical tool becomes necessary. We have thus developed a non-radioisotopic (chemiluminescent) assay for urinary TXB2. Sensitivity has been demonstrated to 5 pg/ml. The method correlates well with gas chromatography/mass spectrometry (the accepted reference method) even without column chromatographic purification prior to the conduct of the chemiluminescent assay (r = 0.96). In addition, we have demonstrated feasibility for a chemiluminescent assay to measure urinary 2,3-dinor TXB2.  相似文献   

13.
The commercially available dye, NanoOrange, has been investigated as a potential tool for clinical diagnostics due to its low cost, ease of use, and ability to detect nanomolar concentrations of protein. Virtually non-fluorescent in dilute aqueous solutions, NanoOrange fluorescence is enhanced by at least an order of magnitude upon non-covalent interaction with proteins. These features, coupled with the requirement for high throughput assays in the clinical laboratory has prompted the development of two orthogonal NanoOrange approaches. Human serum albumin (HSA) was used as a model protein for the development of both 96-well microplate and capillary electrophoresis laser-induced fluorescence (CE–LIF) assay formats. Dye performance in five commonly used buffers of various concentrations and pH indicated considerable flexibility in assay buffer selection, with optimal performance at pH 9.0. A salt concentration study indicated that increasing NaCl concentration generally decreases fluorescence emission and can be minimized by pre-diluting biological samples to a final salt concentration of 20–80 mM. Titration of protein with NanoOrange resulted in optimal HSA–NanoOrange complex formation utilizing 1× and 2× NanoOrange in the 96-well microplate and CE–LIF approaches, respectively. A NanoOrange binding model based on rapid signal enhancement and zero order fluorescence emission kinetics is proposed. The utilization of NanoOrange in CE–LIF based human serum analysis results in a signal-to-background ratio improvement of up to two orders of magnitude.  相似文献   

14.
A simple and convenient microplate assay for glycosidases involved in the glycoprotein-processing reactions is described. The assay is based on specific binding of high-mannose-type oligosaccharide substrates to concanavalin A-Sepharose, while monosaccharides liberated by enzymatic hydrolysis do not bind to concanavalin A-Sepharose. By the use of radiolabeled substrates [( 3H]glucose for glucosidases and [3H]mannose for mannosidases), the radioactivity in the liberated monosaccharides can be determined as a measure of the enzymatic activity. This principle was employed earlier for developing assays for glycosidases previously reported (B. Saunier et al. (1982) J. Biol. Chem. 257, 14155-14161; T. Szumilo and A. D. Elbein (1985) Anal. Biochem. 151, 32-40). These authors have reported the separation of substrate from the product by concanavalin A-Sepharose column chromatography. This procedure is handicapped by the fact that it cannot be used for a large number of samples and is time consuming. We have simplified this procedure and adapted it to the use of a microplate (96-well plate). This would help in processing a large number of samples in a short time. In this report we show that the assay is comparable to the column assay previously reported. It is linear with time and enzyme concentration and shows expected kinetics with castanospermine, a known inhibitor of alpha-glucosidase I.  相似文献   

15.
Cell viability assays are widely used to assess the effect of chemotherapeutic drugs and other agents on cell lines and have shown promise for the prediction of tumour chemosensitivity. In this study we have compared two viability assays using Daudi and CCRF-CEM cell lines over a range of 1500–100,000 cells/well of a microplate. The ATP assay was able to detect the lower limit of 1563 cells/well with luminescence values at least 100× background readings, while the MTT assay could not detect less than 25,000 cells/well above background readings. The ATP assay also showed better reproducibility and sensitivity when cells were grown in microtitre plates over several days, and is particularly useful for the measurement of viability with low cell numbers.  相似文献   

16.
The efficiency of hybridization analysis with oligonucleotide microarrays depends heavily on the method of detection. Conventional methods based on labeling nucleic acids with fluorescent, chemiluminescent, enzyme, or radioactive reporters suffer from a number of serious drawbacks which demand development of new detection techniques. Here, we report two new approaches for detection of hybridization with oligonucleotide microarrays employing magnetic beads as active labels. In the first method streptavidin-coated magnetic beads are used to discover biotin-labeled DNA molecules hybridized with arrayed oligonucleotide probes. In the second method biotin-labeled DNA molecules are bound first to the surface of magnetic beads and then hybridized with arrayed complementary strands on bead-array contacts. Using a simple low-power microscope with a dark-field illumination and a pair of complementary primers as a model hybridization system we evaluated sensitivity, speed, and cost of the new detection method and compared its performance with the detection techniques employing enzyme and fluorescent labels. It was shown that the detection of microarray-hybridized DNA with magnetic beads combines low cost with high speed and enhanced assay sensitivity, opening a new way to routine hybridization assays which do not require precise measurements of DNA concentration.  相似文献   

17.
Replacement of endogenous genes by homologous recombination is rare in plants; the majority of genetic modifications are the result of transforming DNA molecules undergoing random genomic insertion by way of non-homologous recombination. Factors that affect chromatin remodeling and DNA repair are thought to have the potential to enhance the frequency of homologous recombination in plants. Conventional tools to study the frequencies of genetic recombination often rely on stable transformation-based approaches, with these systems being rarely capable of high-throughput or combinatorial analysis. We developed a series of vectors that use chemiluminescent (LUC and REN) reporter genes to assay the relative frequency of homologous and non-homologous recombination in plants. These transient assay vectors were used to screen 14 candidate genes for their effects on recombination frequencies in Nicotiana benthamiana plants. Over-expression of Arabidopsis genes with sequence similarity to SNM1 from yeast and XRCC3 from humans enhanced the frequency of non-homologous recombination when assayed using two different donor vectors. Transient N. benthamiana leaf systems were also used in an alternative assay for preliminary measurements of homologous recombination frequencies, which were found to be enhanced by over-expression of RAD52, MIM and RAD51 from yeast, as well as CHR24 from Arabidopsis. The findings for the assays described here are in line with previous studies that analyzed recombination frequencies using stable transformation. The assays we report have revealed functions in non-homologous recombination for the Arabidopsis SNM1 and XRCC3 genes, so the suppression of these genes' expression offers a potential means to enhance the gene targeting frequency in plants. Furthermore, our findings also indicate that plant gene targeting frequencies could be enhanced by over-expression of RAD52, MIM, CHR24, and RAD51 genes.  相似文献   

18.
Ji X  Lee K  DiPaolo B 《BioTechniques》2002,32(5):1162-1167
Impurity assays for recombinant protein therapeutics are essential to ensure batch-to-batch consistency and to meet the FDA's criteria for a well-characterized biopharmaceutical. For determination of residual host cell DNA, membrane hybridization assays utilizing radiolabeled DNA probes prepared from the host cell's genomic DNA have traditionally been used for products derivedfrom bacterial expression systems to obtain the required low picogram sensitivity. Nonradioactive methods, while desirable to eliminate radioactive waste disposal and safety issues, typically suffer from poor sensitivity and high backgrounds. We report the development of a suitably sensitive, nonradioactive assay to quantitate residual E. coli DNA levels in purified protein drugs by means of a slot-blot hybridization method. The assay utilizes digoxigenin-labeled E. coli DNA probes and SuperSignal chemiluminescent substrate. The optimized chemiluminescent hybridization assay has both low background and high sensitivity, allowing routine detection of 2.5 pg E. coli DNA. The method can be tailored for detection/quantitation of DNA contamination in recombinant protein products expressed in E. coli or other bacterial expression systems.  相似文献   

19.
p56(lck) is a lymphocyte-specific tyrosine kinase that plays an important role in both T-cell maturation and activation. We have developed a homogeneous assay in which p56(lck) catalyzes the transfer of the gamma-phosphate group from [gamma-(33)P]ATP to a biotinylated peptide substrate. The labeled peptide is then captured on a streptavidin-coated scintillation proximity assay (SPA) bead or imaging proximity bead. The SPA is counted in a microplate scintillation counter and the imaging proximity assay is counted in a charge-coupled device-based imaging system called LEADseekertrade mark, recently launched as a homogeneous imaging system by Amersham Pharmacia Biotech. We show, via time-dependence assays and inhibitor studies, that this assay can be performed in 1536-well microplate format using imaging proximity as the method of detection. The results compare favorably with the same assay performed in 384-well microplate format using both SPA and imaging proximity as the detection methods. From this study, we conclude that a kinase assay can be performed in 384- and 1536-well format using imaging as the detection method, with significant time savings over standard scintillation counting. In addition, we show cost saving advantages of 1536- over 384-well format in terms of reagent usage, higher throughput, and waste disposal.  相似文献   

20.
A chemiluminescent assay has been applied to the detection of alkaline phosphatase on PhastGel containing lysates of preimplantation mouse embryos. The very sensitive detection capabilities reported for the chemiluminescent system led to the investigation of its applicability to the characterization of the alkaline phosphatases in one embryo or less and to compare the sensitivity of two different commercial alkaline phosphatase chemiluminescent assays to a colorimetric assay.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号