首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An HPLC- fluorescence method to quantitate total 7-ethyl-10-hydroxy-camptothecin (SN-38) in beagle dog plasma spiked with liposome based formulation of SN-38 (LE-SN38) and using camptothecin (CPT) as the internal standard (I.S.) was developed and validated to support pharmacokinetics/toxicokinetics studies. Sample preparation was done by protein precipitation using acetonitrile with 0.5% acetic acid. The supernatant was evaporated, and reconstituted in acetonitrile-20 mM ammonium acetate, pH 3.5 (20:80, v/v). When injected onto a Zorbax SB-C(18) HPLC column SN-38 as well as I.S. were detected by fluorescence using an excitation at 368 nm and emission at 515 nm. The SN-38 concentrations in samples were calculated from a standard curve of peak area ratios of SN-38 to the I.S. using weighted linear regression. The sensitivity limit for SN-38 was 1.00 ng/ml in beagle dog plasma with a precision (expressed as relative standard deviation) of 12.4% and an accuracy (expressed as analytical recovery) of 104%. The assay was linear within the standard curve range of 1-750 ng/ml. Acceptable precision and accuracy were also obtained for concentrations over the balance of the standard curve range from between-run and within-run calculations.  相似文献   

2.
Huperzine-A (Hup-A), a biologically potent, reversible acetylcholinesterase inhibitor for the treatment of Alzheimer disease (AD) in China, has very low blood concentration. In order to study the pharmacokinetics of newly developed Hup-A transdermal patches in animal, a rapid and sensitive ion-pair reverse-phase high performance liquid chromatography (RP-HPLC) method for the determination of Hup-A in beagle dog serum using mebendazole as internal standard has been developed and validated. The analyte and internal standard were extracted from serum using chloroform-isopropanol (95:5, v/v), analyzed on a C (18) column (5 microm, 150 mm x 4.6 mm i.d.) with a mobile phase consisting of methanol-water-glacial acetic acid (50:48.5:1.5, v/v/v), using sodium dodecylsulfonate as an ion-pair reagent, and detected with UV detector at 313 nm. The chromatographic run time was within 15 min. The assay was linear over the concentration range of 1-12 ng/ml and intra- and inter-day precision over this range was not more than 12.8%. The limit of quantification in serum was 1 ng/ml. The method was successfully applied to characterize the Hup-A concentration-time profiles and study the single and multiple doses phamacokinetics of Hup-A transdermal patches in beagle dogs. The pharmacokinetic study results showed that Hup-A patches has the characteristic of sustained or controlled drug release in vivo.  相似文献   

3.
A sensitive high-performance liquid chromatographic method with fluorescence detection has been developed for determination of MCC-555 (5-[[6-(2-fluorbenzyl)-oxy-2-naphy] methyl]-2,4-thiazolidinedione) in beagle dog plasma. Sample preparation was done by protein precipitation with acetonitrile and a synthetic intermediate of MCC-555 (5-[[6-(2-fluorbenzyl)-oxy-2-naphy] methylene]-2,4-thiazolidinedione) was used as the internal standard (IS). The isocratic mobile phase consisted of acetonitrile-10 mmol/l sodium phosphate buffer (pH 4.5) (65:35, v/v) was delivered at a flow rate of 1 ml/min to a Kromasil C(18) reversed-phase column (250 mm x 4.6 mm, 5 microm). The compounds were detected by fluorescence detection, using an excitation wavelength of 232 nm, and emission wavelength of 352 nm. Calibration curves of MCC-555 were linear in the concentration range of 0.005-2.0 microg/ml. Intra- and inter-day precision ranged from 3.4 to 5.4% and 3.0 to 8.8%, respectively. No endogenous interferences were observed with either MCC-555 or IS. The assay is simple, economical, precise, and is directly applicable to pharmacokinetic studies in beagle dogs involving three dose administrations.  相似文献   

4.
A liquid chromatographic method is described for the simultaneous determination of cefalexin and trimethoprim in dog plasma. A simple protein precipitation procedure was adopted for the sample preparation with satisfactory extraction recoveries for both analytes. Chromatographic separation of the analytes was achieved on a C(18) column using a mixture of 2 mol/l formate buffer (pH 3.5), methanol and acetonitrile (22:7:7, v/v/v) containing a 0.002 mol/l sodium dodecyl sulfate as mobile phase and detection was performed at 240 nm. The linearity was obtained over the concentration ranges of 1.0-100.0 microg/ml for cefalexin and 0.5-50.0 microg/ml for trimethoprim. For each level of QC samples including the lower limit of quantification, both inter- and intra-day precisions (R.S.D.) were < or =14.0% for cefalexin and < or =11.4% for trimethoprim, and accuracy (RE) was -1.4% for cefalexin and -3.0% for trimethoprim. The present LC method was successfully applied to the pharmacokinetic studies of coformulated cefalexin dispersible tablets after oral administration to beagle dogs.  相似文献   

5.
A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometric method is described for the determination of tamsulosin in dog plasma. Tamsulosin was extracted from plasma using a mixture of hexane-ethyl acetate (2:1, v/v) and separated on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. The mobile phase consisting of a mixture of methanol, water and formic acid (80:20:1, v/v/v) was delivered at a flow rate of 0.5 ml/min. Atmospheric pressure chemical ionization (APCI) source was operated in positive ion mode. Selected reaction monitoring (SRM) mode using the transitions of m/z 409-->m/z 228 and m/z 256-->m/z 166.9 were used to quantify tamsulosin and the internal standard, respectively. The linearity was obtained over the concentration range of 0.1-50.0 ng/ml for tamsulosin and the lower limit of quantitation was 0.1 ng/ml. For each level of QC samples, inter- and intra-run precision was less than 5.0 and 4.0% (relative standard deviation (R.S.D.)), respectively, and accuracy was within +/-0.3% (relative error (R.E.)). This method was successfully applied to pharmacokinetic study of a tamsulosin formulation product after oral administration to beagle dogs.  相似文献   

6.
A liquid chromatography-mass spectrometry method is described for the determination of tetramethylpyrazine (TMP) and its active metabolite, 2-hydroxymethyl-3,5,6-trimethylpyrazine (HTMP) in dog plasma. This method involves a plasma clean-up step using protein precipitation procedure followed by LC separation and positive electrospray ionization mass spectrometry detection (ESI-MS). Chromatographic separation of the analytes was achieved on a C18 column using a mobile phase of methanol, water and acetic acid (50:50:0.6, v/v/v) at a flow rate of 1.0 ml/min. Selected ion monitoring (SIM) mode was used for analyte quantitation at m/z 137.2 for TMP, m/z 153.2 for HTMP and m/z 195.2 for caffeine. The linearity was obtained over the concentration ranges of 20-6000 ng/ml for TMP and 20-4000 ng/ml for HTMP and the lower limit of quantitation was 20 ng/ml for both analytes. For each level of QC samples, both inter- and intra-day precisions (R.S.D.) were 相似文献   

7.
Based on the theory of stochastic resonance, the signal to noise ratio (SNR) of HPLC/UV chromatographic signal of roxithromycin is enhanced by cooperation of signal, noise and nonlinear system. A simple new method for the determination of low concentration of roxithromycin in beagle dog plasma is presented. Using signal enhancement by stochastic resonance, this method extends the limit of quantitation from the reported 0.5 to 0.1 microg/ml. During validation of the new method, HPLC/MS was used as a comparison technique. The results indicate that the recovery and low concentrations of roxithromycin in beagle dog plasma were equivalent between the two methods (P>0.05). Stochastic resonance may be a promising tool for improving detection limits in trace analysis.  相似文献   

8.
A rapid and sensitive method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of codeine, ephedrine, guaiphenesin and chlorpheniramine in beagle dog plasma has been developed and validated. Following liquid-liquid extraction, the analytes were separated on a reversed-phase C(18) column (150 mm × 2.0 mm, 3 μm) using formic acid:10 mM ammonium acetate:methanol (0.2:62:38, v/v/v) as mobile phase at a flow rate of 0.2 mL/min and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode. The method was linear for all analytes over the following concentration (ng/mL) ranges: codeine 0.08-16; ephedrine 0.8-160; guaiphenesin 80-16,000; chlorpheniramine 0.2-40. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. It is the first time that the validated HPLC-MS/MS method was successfully applied to a bioequivalence study in 6 healthy beagle dogs.  相似文献   

9.
A simple, rapid and reliable method was developed for the quantification of oxymatrine (OMT) and its metabolite matrine (MT) in beagle dog plasma using a liquid-liquid extraction procedure followed by liquid chromatography-electrospray ionization mass spectrometric (LC-ESI-MS) analysis. Extend-C18 column (2.1 mm i.d. x 50 mm, 5 microm) with a C18 guard column (2.1 mm i.d. x 12.5 mm) was used as the analytical column. Linear detection responses were obtained for OMT concentration ranging from 5 to 4000 ng/ml and for MT concentration ranging from 5 to 2000 ng/ml. The precision and accuracy data, based on intra- and inter-day variations over 5 days, were lower than 5%. The limit of quantitation for OMT and MT were 2 and 1 ng/ml, respectively, and their recoveries were greater than 90%. Pharmacokinetic data of OMT and its active metabolite MT obtained with this method following a single oral dose of 300 mg OMT capsules to six beagle dogs was also reported for the first time.  相似文献   

10.
A capsule containing an aromatase inhibitor (4-androsten-4-ol-3,17-dione) was subcutaneously implanted in four oligozoospermic beagle dogs and one azoospermic beagle dog with high plasma estradiol-17beta (E2) concentrations (15-19 pg/ml) and low plasma testosterone (T) concentrations (0.6-0.8 ng/ml) for 8 weeks and the effect of the aromatase inhibitor on spermatogenic dysfunction was assessed. Plasma E2 and T concentrations and semen quality were examined at 1 week intervals from 3 weeks before to 12 weeks after the start of treatment. Testicular biopsies were done twice (capsule implantation and removal). Plasma E2 concentrations of all dogs decreased (9-14 pg/ml) and plasma T concentrations increased (2.0-2.6 ng/ml) from 3 weeks after capsule implantation to capsule removal. The mean number of spermatozoa ejaculated by all four oligozoospermic dogs between 4 and 9 weeks after implantation was higher (127 x 10(6) to 205 x 10(6)) than before implantation (20 x 10(6) to 38 x 10(6)) (P < 0.05 and 0.01). Very low numbers (2 x 10(4) to 4 x 10(4)) of immotile spermatozoa were observed between 7 and 8 weeks after implantation in the semen collected from the dog with azoospermia. Before implantation, a few spermatozoa were seen in only one-fifth of the seminiferous tubules in this dog; 8 weeks after implantation, the mean diameter and mean number of round spermatids in the seminiferous tubules in all five dogs were higher than before implantation (P < 0.05). Implantation of the capsule containing the aromatase inhibitor in infertile dogs with abnormally high plasma E2 concentrations improved their spermatogenic function, concurrent with decreased plasma E2 and increased plasma T.  相似文献   

11.
Subpleural concentrations of He and SF6 were measured during multiple-breath washouts from isolated dog lungs. Tidal volume, inspiratory flow, and frequency were in the normal range of canine ventilation. For each gas, there was a local minimum in concentration during inspiration (Cinsp) and a local maximum in concentration during exhalation (Cexp). SF6 exhibited a deeper inspiratory trough than He for each breath of every washout. For large tidal volumes (10-20 ml/kg), Cexp approximated a single exponential decay and He was cleared more rapidly than SF6. For small tidal volumes (2.5 ml/kg), Cexp was multiexponential and SF6 was cleared more rapidly than He. Cinsp/Cexp (a measure of the depth of the inspiratory trough) and the kinetics of Cexp decay were determined for washouts using a tidal volume of 10 and 20 ml/kg and different inspiratory flows. Under all conditions, an increase of inspiratory flow resulted in a deeper inspiratory trough for both He and SF6. For washouts using 10 ml/kg and 60 breaths/min, an increase of inspiratory flow increased the clearance of both gases. In washouts using lower ventilatory frequencies, gas clearance was independent of inspiratory flow. These findings are contrary to predictions of contemporary models of convection and diffusion in the lung. This study suggests that convective axial mixing and radial diffusion in the airways are important determinants of pulmonary gas transport.  相似文献   

12.
In the search for its role in inflammatory joint diseases, soluble HLA-DR (sHLA-DR) was quantitated in 72 synovial fluids (SF) by a newly established immunoenzyme assay. Unlike other soluble receptors which accumulated only moderately (sCD25, sCD4) or negligibly (sHLA class I, sCD8) in the SF, SF sHLA-DR levels exceeded serum levels by up to 3 orders of magnitude and varied disease dependently from "control" values (traumatic synovitis and osteoarthritis: 9.9 +/- 6.1 ng/ml). Clear-cut different SF sHLA-DR values in HLA-DR-associated "rheumatoid-like" (136.5 +/- 130.0 ng/ml) vs HLA-B27-associated "spondylarthropathy-like" arthritic forms (28.4 +/- 29.1 ng/ml) were most significant comparing oligoarticular juvenile chronic arthritis type I (147.6 +/- 112.6 ng/ml) and type II (3.3 +/- 1.1 ng/ml), thus offering a new classification marker. Also ex vivo, large amounts of sHLA-DR were released spontaneously by SF mononuclear cells and found to be related to the T-cell activation state. SF sHLA-DR may be shed in large complexes or micelles, as it eluted mainly at >450 kDa on gel filtration. Western blotting revealed that the majority of SF sHLA-DR consisted of full-length alpha- and beta-chains. Minor fractions of smaller sized antigens seemed to be generated by proteolytic cleavage rather than by alternative splicing, since only minute amounts of HLA-DRB mRNA lacking the transmembrane exon could be amplified by RT-PCR. Distinct forms of high-dose sHLA-DR, able to provoke rather than to suppress T-cell responses, are discussed as contributing to some HLA-DR disease association.  相似文献   

13.
Sf-9 insect cells were adapted to three different serum-free media (SF900II, EXCELL 401 and IPL/41 supplemented) in 125 ml stirred vessels by gradually reducing serum concentration from 10 to 0% (v/v). TC100 medium sup-plemented with 10% fetal bovine serum was used as control. With this procedure it was possible to obtain cells fully adapted to SF900II and EXCELL 401 in 5 weeks. The adapted cells could be frozen in serum-free medium and thawed without any decrease in specific growth rate or maximum cell concentration. Even after 4 months of culture in stirred vessels at 170 rpm the specific growth rate and maximum cell concentration (0.031 h and 4.8 × 10 cells/ml, respectively) remained constant.  相似文献   

14.
An HPLC assay for plasma analysis of LY303366 (I), a semi-synthetic lipopeptide antifungal related to echinocandin B (ECB), was developed to support the selection and subsequent preclinical development of I. The method involved extraction of I from plasma with the aid of solid-phase extraction (SPE) cartidges followed by reversed-phase HPLC with UV detection at 300 nm. The method is simple, selective and is applicable to dog, rat, mouse and rabbit plasma. Validation studies using dog plasma showed that the values obtained for parameters of linearity, precision and accuracy were within acceptable limits. Based on analysis of 0.3 ml of plasma, the lower limit of quantitation was 20 ng/ml. The method has been successfully applied to determine the pharmacokinetic parameters of I in the dog following intravenous (i.v.) and oral administration. Compared to first generation ECB antifungal agents, the results of the i.v. dog study indicated a 50% reduction in clearance of the drug from plasma (0.1 l/h/kg) and an 18-fold increase in the volume of distribution at steady state (1.8 l/kg). When administered orally, compound I had an absolute bioavailability of 9%; however, plasma levels remained above the MIC for C. albicans (0.005 μg/ml) through 48 h. Given the excellent potency of I and its broad spectrum of activity relative to first generation ECB antifungal agents, the assay results for I indicate the potential for its use as a broad spectrum i.v. and oral antifungal agent.  相似文献   

15.
A newly developed assay for hydroxyproline (Hyp) in physiological samples was used for determining the biological variations in serum total Hyp in the beagle dog. The results showed that dietary Hyp restriction in the beagle dog results in a significant decrease in serum total Hyp over the first 24 h and that there are no obvious circadian variations in serum total Hyp concentrations in beagle dogs on dietary Hyp restriction.  相似文献   

16.
This study evaluated the effects of rat ANP(5-28) infusion into the blood-perfused dog gracilis muscle at concentrations ranging from 30 to 10,000 pg/ml. The vasculature of gracilis muscles from anesthetized beagle dogs was isolated and pump-perfused at constant flow with blood utilizing an extracorporeal circuit. Maximal vasodilatory capacity was determined by adenosine injection. ANP was infused into the arterial circuit to produce increasing arterial blood concentrations. Each infusion lasted 10 min. Systemic arterial pressure, central venous pressure, cardiac output and heart rate did not change during ANP infusion into the gracilis vasculature. ANP at arterial blood concentrations up to 10,000 pg/ml did not produce significant vasodilation although the vasculature showed pronounced vasodilation in response to adenosine. In vitro experiments showed that ANP had much less vasorelaxant activity in dog femoral artery and saphenous vein than in rabbit aorta. Therefore, rat ANP(5-28) at concentrations within and well above physiological and pharmacological ranges does not inhibit the basal vascular tone present in the innervated, blood-perfused dog gracilis muscle in situ.  相似文献   

17.
An enantioselective high-performance liquid chromatographic assay for the quantification of methadone in human and beagle plasma is described. The procedure involves extraction of methadone from alkalized plasma into hexane—isoamyl alcohol (99:1, v/v). Stereoselective separation was achieved with a silica column with covalently bound α1-acid glycoprotein (Chiral-AGP) without any derivatization procedure. The detection wavelength was set at 215 nm. Using an internal standard provided reliable control of the extraction procedure as well as quantification of the enantiomers of methadone. The limit of quantification was found to be 2.5 ng/ml. The method was demonstrated to be sufficiently sensitive for stereoselective pharmacokinetic studies of methadone.  相似文献   

18.
Astragaloside IV is a novel cardioprotective agent extracted from the Chinese medical herb Astragalus membranaceus (Fisch) Bge. This agent is being developed for treatment for cardiovascular disease. Further development of Astragaloside IV will require detailed pharmacokinetic studies in preclinical animal models. Therefore, we established a sensitive and accurate high performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (LC/MS/MS) quantitative detection method for measurement of Astragaloside IV levels in plasma, urine as well as other biological samples including bile fluid, feces and various tissues. Extraction of Astragaloside IV from plasma and other biological samples was performed by Waters OASIS(trade mark) solid phase extraction column by washing with water and eluting with methanol, respectively. An aliquot of extracted residues was injected into LC/MS/MS system with separation by a Cosmosil C18 5 microm, 150 mm x 2.0 mm) column. Acetonitrile:water containing 5 microM NaAc (40:60, v/v) was used as a mobile phase. The eluted compounds were detected by tandem mass spectrometry. The average extraction recoveries were greater than 89% for Astragaloside IV and digoxin from plasma, while extraction recovery of Astragaloside IV and digoxin from tissues, bile fluid, urine and fece ranged from 61 to 85%, respectively. Good linearity (R2>0.9999) was observed throughout the range of 10-5000 ng/ml in 0.5 ml rat plasma and 5-5000 ng/ml in 0.5 ml dog plasma. In addition, good linearity (R2>0.9999) was also observed in urine, bile fluid, feces samples and various tissue samples. The overall accuracy of this method was 93-110% for both rat plasma and dog plasma. Intra-assay and inter-assay variabilities were less than 15.03% in plasma. The lowest quantitation limit of Astragaloside IV was 10 ng/ml in 0.5 ml rat plasma and 5 ng/ml in 0.5 ml dog plasma, respectively. Practical utility of this new LC/MS/MS method was confirmed in pilot pharmacokinetic studies in both rats and dogs following intravenous administration.  相似文献   

19.
Existing methods to determine neferine, a bisbenzylisoquinline alkaloid, either have no internal standard or lack selectivity, or take longer time. Here an improved reverse-phase high-performance liquid chromatographic (RP-HPLC) method was established in biological samples. The extraction recovery was 90.9% for neferine at concentration level of 0.2 microg/ml and 77.7% for dauricine (the internal standard) at 5 microg/ml in dog plasma, respectively. The linear quantification range of the method was 25-2000 ng/ml in dog plasma, with linear correlation coefficients greater than 0.999. The intra-day and inter-day relative standard deviations (R.S.D.s) for neferine at 50, 200 and 1000 ng/ml levels in dog plasma fell in the range of 3.0-5.4% and 4.3-9.5%, respectively. The RP-HPLC method was successfully applied to a pharmacokinetics study, in which experimental dogs received a single dose of neferine (5 mg/kg i.v. or 10 mg/kg p.o.). The pharmacokinetic result was presented.  相似文献   

20.
A selective and sensitive high-performance liquid chromatographic assay for a novel cognitive enhancer, X9121 (I), and its mono N-oxide metabolite, XG696 (II), in dog plasma has been developed. Compounds I, II and internal standard (I.S.) were first extracted from dog plasma using a solid-phase Bond Elut Certify I 10-ml LRC reservoir extraction cartridge. Chromatographic separation of I, II and I.S. was conducted on a reversed-phase Zorbax Stable Bond cyano column. Ammonium acetate buffer (0.05 M, pH 6)-acetonitrile-triethylamine (75:25:0.1, v/v) was used as the mobile phase. Detection of all three compounds was by UV light absorbance at 313 nm. Using 0.5 ml of dog plasma for extraction, the minimum quantifiable limit was 10 ng/ml and the assay was linear from 10 to 5400 ng/ml. The coefficients of variation for intra-day precision ranged from 2.2 to 8.5% for I and from 2.5 to 9.8% for II. The coefficients of variation for the inter-day precision for these two compounds ranged from 2.6 to 9.0% and from 3.6 to 16.2%, respectively. The absolute percent differences for the accuracy results were within 11.0% of the spiked concentrations. Compounds I and II were stable in frozen plasma at −20°C for at least 67 days.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号