首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The following is Part B of a two-part study. Part A evaluated, biomechanically, intramedullary (IM) nails versus locking plates for fixation of an extra-articular, metaphyseal wedge fracture in synthetic osteoporotic bone. Part B of this study introduces deterministic finite element (FE) models of each construct type in synthetic osteoporotic bone and investigates the probability of periprosthetic fracture of the locking plate compared with the retrograde IM nail using Monte Carlo simulation. Deterministic FE models of the fractured femur implanted with IM nail and locking plate, respectively, were developed and validated using experimental data presented in Part A of this study. The models were validated by comparing the load-displacement curve of the experimental data with the load-displacement curve of the FE simulation with a root-mean square error of less than 3?mm. The validated FE models were then modified by defining the cortical and cancellous bone modulus of elasticity as uncertain variables that could be assumed to vary randomly. Monte Carlo simulation was used to evaluate the probability of fracture (POF) of each fixation. The POF represents the cumulative probability that the predicted shear stresses in the cortical bone will exceed the expected shear strength of the cortical bone. This investigation provides information regarding the significance of post-operative damage accumulation on the POF of the implanted bones when the two fixations are used. The probabilistic analysis found the locking plate fixation to have a higher POF than the IM nail fixation under the applied loading conditions (locking plate 21.8% versus IM nail 0.019%).  相似文献   

2.
An obvious means to improve the fixation of a cancellous bone screw is to augment the surrounding bone with cement. Previous studies have shown that bone augmentation with Calcium Phosphate (CaP) cement significantly improves screw fixation. Nevertheless, quantitative data about the optimal distribution of CaP cement is not available. The present study aims to show the effect of cement distribution on the screw fixation strength for various cortical thicknesses and to determine the conditions at which cement augmentation can compensate for the absence of cortical fixation in osteoporotic bone. In this study, artificial bone materials were used to mimic osteoporotic cancellous bone and cortical bone of varying thickness. These bone constructs were used to test the fixation strength of cancellous bone screws in different cortical thicknesses and different cement augmentation depths. The cement distribution was measured with microCT. The maximum pullout force was measured experimentally. The microCT analysis revealed a pseudo-conic shape distribution of the cement around the screws. While the maximum pullout strength of the screws in the artificial bone only was 30±7 N, it could increase up to approximately 1000 N under optimal conditions. Cement augmentation significantly increased pullout force in all cases. The effect of cortical thickness on pullout force was reduced with increased cement augmentation depth. Indeed, cement augmentation without cortical fixation increased pullout forces over that of screws without cement augmentation but with cortical fixation. Since cement augmentation significantly increased pullout force in all cases, we conclude that the loss of cortical fixation can be compensated by cement augmentation.  相似文献   

3.
This paper presents a finite element (FE) model to identify parameters that affect the performance of an improved cancellous bone screw fixation technique, and hence potentially improve fracture treatment. In cancellous bone of low apparent density, it can be difficult to achieve adequate screw fixation and hence provide stable fracture fixation that enables bone healing. Data from predictive FE models indicate that cements can have a significant potential to improve screw holding power in cancellous bone. These FE models are used to demonstrate the key parameters that determine pull-out strength in a variety of screw, bone and cement set-ups, and to compare the effectiveness of different configurations. The paper concludes that significant advantages, up to an order of magnitude, in screw pull-out strength in cancellous bone might be gained by the appropriate use of a currently approved calcium phosphate cement.  相似文献   

4.
Purpose: The purpose of this study was to study the potential of novel biodegradable PCL bone cement to improve bone screw fixation strength in osteoporotic bone. Methods: The biomechanical properties of bone cement (ε-polycaprolactone, PCL) and fixation strength were studied using biomechanical tests and bone screws fixed in an osteoporotic bone model. Removal torques and pullout strengths were assessed for cortical, self-tapping, and cancellous screws inserted in the osteoporotic bone model (polyurethane foam blocks with polycarbonate plate) with and without PCL bone cement. Open cell and cellular rigid foam blocks with a density of 0.12 g/cm3 were used in this model. Results: Removal torques were significantly (more than six-fold) improved with bone cement for cancellous screws. Furthermore, the bone cement improved pullout strengths three to 12 times over depending on the screw and model material.?Conclusions: Biodegradable bone cement turned out to be a very potential material to stabilize screw fixation in osteoporotic bone. The results warrant further research before safe clinical use, especially to clarify clinically relevant factors using real osteoporotic bone under human body conditions and dynamic fatigue testing for long-term performance.  相似文献   

5.

Background

The purpose of this study was to design a customized fixation plate for mandibular angle fracture using topological optimization based on the biomechanical properties of the two conventional fixation systems, and compare the results of stress, strain and displacement distributions calculated by finite element analysis (FEA).

Methods

A three-dimensional (3D) virtual mandible was reconstructed from CT images with a mimic angle fracture and a 1 mm gap between two bone segments, and then a FEA model, including volume mesh with inhomogeneous bone material properties, three loading conditions and constraints (muscles and condyles), was created to design a customized plate using topological optimization method, then the shape of the plate was referenced from the stress concentrated area on an initial part created from thickened bone surface for optimal calculation, and then the plate was formulated as “V” pattern according to dimensions of standard mini-plate finally. To compare the biomechanical behavior of the “V” plate and other conventional mini-plates for angle fracture fixation, two conventional fixation systems were used: type A, one standard mini-plate, and type B, two standard mini-plates, and the stress, strain and displacement distributions within the three fixation systems were compared and discussed.

Results

The stress, strain and displacement distributions to the angle fractured mandible with three different fixation modalities were collected, respectively, and the maximum stress for each model emerged at the mandibular ramus or screw holes. Under the same loading conditions, the maximum stress on the customized fixation system decreased 74.3, 75.6 and 70.6% compared to type A, and 34.9, 34.1, and 39.6% compared to type B. All maximum von Mises stresses of mandible were well below the allowable stress of human bone, as well as maximum principal strain. And the displacement diagram of bony segments indicated the effect of treatment with different fixation systems.

Conclusions

The customized fixation system with topological optimized structure has good biomechanical behavior for mandibular angle fracture because the stress, strain and displacement within the plate could be reduced significantly comparing to conventional “one mini-plate” or “two mini-plates” systems. The design methodology for customized fixation system could be used for other fractures in mandible or other bones to acquire better mechanical behavior of the system and improve stable environment for bone healing. And together with SLM, the customized plate with optimal structure could be designed and fabricated rapidly to satisfy the urgent time requirements for treatment.
  相似文献   

6.
7.
The presence of a femoral prosthesis superior to a shaft fracture severely complicates fixation and treatment. This study uses two-dimensional, multithickness, plane stress finite-element models of a femur with prosthesis to investigate the stresses developed with the application of three popular fixation techniques: revision to a long stem prosthesis, lateral plating with a cortical bone allograft strut and cerclage wires, and custom plate application with proximal Parham band fixation with distal cortical screws (Ogden plate). The plate and bone contact as well as the fracture site contact were modelled by using orthotropic elements with custom-fit moduli so that only the normal stress to the interface was significant. A thermal analogy was used to model the cerclage and Parham band preloads so that representative preloads in the proximal fixation of the two types of plate treatments could be modelled. A parametric study was performed with the long-prosthesis model to show variations in stem lengths of one, two and three femoral diameters distal to the fracture site. The Ogden plate model showed a transfer of tensile stress near the proximal-most band, with the highest tensile stress being at the fracture site with evidence of stress shielding of the proximal lateral cortex. The cortical bone strut model showed a transfer of tensile stress to the bone strut but showed less shielding of the proximal cortex. The cerclage wires at the base of the bone strut showed the highest changes in load with the distalmost wire increasing to almost four times its original preload.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

8.
Investigations are reported in the literature, by means of experimental, analytical and numerical methods, concerning the biomechanical properties of bone. However, the evolutionary phenomena of bone fracture healing does not have a large reference literature. This work investigates and describes the behaviour of inclined human femur fractures with external fixation up to complete healing. A numerical formulation based on the finite element method has been adopted. Geometric configuration is defined using data from a magnetic resonance process applied to a femur in vivo. A three dimensional model has been developed by adopting an orthotropic material law for cortical bone and an isotropic law for the fracture gap zone. Stress and strain reponses of the bone and fixation device are investigated with reference to the evolutionary behaviour of the healing tissue.  相似文献   

9.
Prediction of femoral head collapse in osteonecrosis   总被引:6,自引:0,他引:6  
The femoral head deteriorates in osteonecrosis. As a consequence of that, the cortical shell of the femoral head can buckle into the cancellous bone supporting it. In order to examine the buckling scenario we performed numerical analysis of a realistic femoral head model. The analysis included a solution of the hip contact problem, which provided the contact pressure distribution, and subsequent buckling simulation based on the given contact pressure. The contact problem was solved iteratively by approximating the cartilage by a discrete set of unilateral linear springs. The buckling calculations were based on a finite element mesh with brick elements for the cancellous bone and shell elements for the cortical shell. Results of 144 simulations for a variety of geometrical, material, and loading parameters strengthen the buckling scenario. They, particularly, show that the normal cancellous bone serves as a strong supporting foundation for the cortical shell and prevents it from buckling. However, under the development of osteonecrosis the deteriorating cancellous bone is unable to prevent the cortical shell from buckling and the critical pressure decreases with the decreasing Young modulus of the cancellous bone. The local buckling of the cortical shell seems to be the driving force of the progressive fracturing of the femoral head leading to its entire collapse. The buckling analysis provides an additional criterion of the femoral head collapse, the critical contact pressure. The buckling scenario also suggests a new argument in speculating on the femoral head reinforcement. If the entire collapse of the femoral head starts with the buckling of the cortical shell then it is reasonable to place the reinforcement as close to the cortical shell as possible.  相似文献   

10.
The skeleton accommodates changes in mechanical environments by increasing bone mass under increased loads and decreasing bone mass under disuse. However, little is known about the adaptive changes in micromechanical behavior of cancellous and cortical tissues resulting from loading or disuse. To address this issue, in vivo tibial loading and hindlimb unloading experiments were conducted on 16-week-old female C57BL/6J mice. Changes in bone mass and tissue-level strains in the metaphyseal cancellous and midshaft cortical bone of the tibiae, resulting from loading or unloading, were determined using microCT and finite element (FE) analysis, respectively. We found that loading- and unloading-induced changes in bone mass were more pronounced in the cancellous than cortical bone. Simulated FE-loading showed that a greater proportion of elements experienced relatively lower longitudinal strains following load-induced bone adaptation, while the opposite was true in the disuse model. While the magnitudes of maximum or minimum principal strains in the metaphyseal cancellous and midshaft cortical bone were not affected by loading, strains oriented with the long axis were reduced in the load-adapted tibia suggesting that loading-induced micromechanical benefits were aligned primarily in the loading direction. Regression analyses demonstrated that bone mass was a good predictor of bone tissue strains for the cortical bone but not for the cancellous bone, which has complex microarchitecture and spatially-variant strain environments. In summary, loading-induced micromechanical benefits for cancellous and cortical tissues are received primarily in the direction of force application and cancellous bone mass may not be related to the micromechanics of cancellous bone.  相似文献   

11.
A three-dimensional finite element analysis of the upper tibia   总被引:1,自引:0,他引:1  
A three-dimensional finite element model of the proximal tibia has been developed to provide a base line for further modeling of prosthetic resurfaced tibiae. The geometry for the model was developed by digitizing coronal and transverse sections made with the milling machine, from one fresh tibia of average size. The load is equally distributed between the medial and lateral compartments over contact areas that were reported in the literature. An indentation test has been used to measure the stiffness and the ultimate strength of cancellous bone in four cadaver tibiae. These values provided the statistical basis for characterising the inhomogeneous distribution of the cancellous bone properties in the proximal tibia. All materials in the model were assumed to be linearly elastic and isotropic. Mechanical properties for the cortical bone and cartilage have been taken from the literature. Results have been compared with strain gage tests and with a two-dimensional axisymmetric finite element model both from the literature. Qualitative comparison between trabecular alignment, and the direction of the principal compressive stresses in the cancellous bone, showed a good relationship. Maximum stresses in the cancellous bone and cortical bone, under a load which occurs near stance phase during normal gait, show safety factors of approximately eight and twelve, respectively. The load sharing between the cancellous bone and the cortical bone has been plotted for the first 40 mm distally from the tibial eminence.  相似文献   

12.
Osteoporosis is a common and serious complication of glucocorticoid therapy, resulting in increased risk of fragility fractures. Recent studies indicate that fracture risk is increased even at low doses of glucocorticoids and that this increased risk is seen soon after the commencement of glucocorticoid therapy. Both increased bone resorption and reduced bone formation contribute to bone loss, which affects cortical and cancellous sites. A number of interventions have been shown to prevent glucocorticoid-induced bone loss, although the strongest evidence exists for the bisphosphonates etidronate, alendronate and risedronate. Primary prevention of bone loss should be considered in all high-risk individuals taking oral glucocorticoids for 3 months or more, for example those aged 65 years or over or those with a previous fragility fracture. In other glucocorticoid-treated individuals, the decision to treat should be based on bone densitometry.  相似文献   

13.
PurposeTo quantitatively assess CT image quality and fracture visibility using virtual monochromatic imaging and iterative metal artifact reduction (iMAR) in a femoral bone fracture phantom with different fixation implants.MethodsA custom made phantom was scanned at 120-kVp and 140-kVp single-energy and 100/150-kVp dual-energy. Three stainless steel and two titanium implants with different thicknesses were placed on the phantom containing simulated one and two mm fractures. Single-energy CT images were reconstructed with and without iMAR, while DECT images were reconstructed at monochromatic energies between 70 and 190 keV. Non-metal scans were used as a reference. A Fourier power spectrum method and fracture model were used to analyze several anatomical areas.ResultsCT-value deviations of titanium implants were much lower compared to stainless steel implants. These deviations decreased for both DECT and iMAR. Fracture visibility, measured with the fracture model, improved the most when DECT was used while artifact reduction benefitted more from iMAR. The optimal monochromatic energy for metal artifact reduction, based on CT-value deviation, varied for each metal between 130 and 150 keV. The fracture model provided a signal-to-noise ratio for the near metal fracture visibility, providing the optimal keV.ConclusioniMAR and high keV monochromatic images extracted from DECT both reduce metal artifacts caused by different metal fixation implants. Quantitative femoral phantom results show that DECT is superior to iMAR regarding fracture visualization adjacent to metal fixation implants. The introduction of new artifacts when using iMAR impedes its value in near metal fixation implant imaging.  相似文献   

14.
A number of screws commonly used for internal fixation in scaphoid bone fractures and nonunions are compared regarding biomechanical properties and clinical applicability. The experiments were carried out on models made of ash-wood, representing a reconstruction and fixation as is performed in a cortico-cancellous inlay bone graft for scaphoid non-union. For fixation use was made of 2.7 and 3.5 AO/ASIF cortical screws respectively, 4.0 AO/ASIF cancellous screws, Herbert screws, and a newly designed screw called the three components screw (D.K.S.). The models with implanted screws were tested for bending strength, tensile strength and torsion stability. No large differences between the various screws were found regarding the measured parameters, so that a small intra-osteal implant such as the Herbert screw and the D.K.S., which can be inserted easily and which gives a certain amount of interfragmentary compression, will be sufficient for osteosynthesis of the scaphoid bone. In case an intra-osteal implant is not available a single 3.5 AO/ASIF cortical screw, inserted following lag-screw principles, is recommended.  相似文献   

15.
This study aimed to develop and validate a finite element (FE) model of a human clavicle which can predict the structural response and bone fractures under both axial compression and anterior–posterior three-point bending loads. Quasi-static non-injurious axial compression and three-point bending tests were first conducted on a male clavicle followed by a dynamic three-point bending test to fracture. Then, two types of FE models of the clavicle were developed using bone material properties which were set to vary with the computed tomography image density of the bone. A volumetric solid FE model comprised solely of hexahedral elements was first developed. A solid-shell FE model was then created which modelled the trabecular bone as hexahedral elements and the cortical bone as quadrilateral shell elements. Finally, simulations were carried out using these models to evaluate the influence of variations in cortical thickness, mesh density, bone material properties and modelling approach on the biomechanical responses of the clavicle, compared with experimental data. The FE results indicate that the inclusion of density-based bone material properties can provide a more accurate reproduction of the force–displacement response and bone fracture timing than a model with uniform bone material properties. Inclusion of a variable cortical thickness distribution also slightly improves the ability of the model to predict the experimental response. The methods developed in this study will be useful for creating subject-specific FE models to better understand the biomechanics and injury mechanism of the clavicle.  相似文献   

16.
This communication reports the results of a three-dimensional finite element (FE) model of stresses in a surgically altered femur and tibia. The model incorporated a novel approach in implementing orthotropic and inhomogeneous bone properties and non-uniform distributed loading. Cortical, cancellous, and subchondral bone of the femur and the tibia were modeled. Mechanical properties for the cortical and cancellous bone were mapped from published data characterizing the anisotropy and inhomogeneity of the bone properties. Mesh adequacy was determined using stress convergence and strain energy error convergence. Qualitatively, the results of the study compare well with experimental principal compressive strains from the literature. With respect to tunnel placement in anterior cruciate ligament reconstruction, the model predicted stress-shielding at the postero-lateral region of the tunnel wall, and increased stress at the postero-medial region of the tunnel wall. The stresses in the cancellous bone beneath the tunnel were, in general, lower than those above the tunnel. Prolonged stress shielding leads to bone resorption of the posterior tunnel wall leading to tunnel enlargement, and possible compromise of the ACL reconstruction. The stresses on the femoral cortex produced from a button-type fixation were noticeable for low levels of loading; the stress levels were very similar in models incorporating bone properties of patients aged 45 and 65. Repeated compression of the femoral cortex at these stress levels may cause microdamage to the cortex eventually resulting in fatigue failure.  相似文献   

17.
The purpose of the present study was to examine the effects of combined administration of alfacalcidol (ALF) and risedronate (RIS) on cancellous and cortical bone mass of the tibia in glucocorticoid (GC)-treated young rats. One hundred and nine female Sprague-Dawley rats, 3 months of age, were randomly divided by the stratified weight method into eleven groups according to the following treatment schedule: baseline control, a 4-week age-matched control, and a 4-week GC administration with a 4-week concomitant administration of vehicle, ALF, RIS, or ALF+RIS, and an 8-week age-matched control and 8-week GC administration with a 4-week administration of vehicle, ALF, RIS, or ALF+RIS that was initiated after a 4-week administration of GC. The GC (methylprednisolone sodium succinate, 5.0 mg/kg) and RIS (10 microg/kg) were administered subcutaneously 3 times a week. ALF (0.08 microg/kg) was administered orally 5 times a week. At the end of the experiment, static and dynamic bone histomorphometric analyses were performed on cancellous bone of the proximal tibial metaphysis and cortical bone of the tibial diaphysis. A 4-week GC administration induced a loss of cancellous bone volume/total tissue volume (BV/TV) compared with the age-matched control as a result of decreased bone formation and increased bone erosion, while an 8-week GC administration induced both losses of cancellous BV/TV and of percent cortical area (Ct Ar) compared with the age-matched control as a result of decreased trabecular bone formation and increased trabecular and endocortical bone erosion. ALF prevented the loss of cancellous BV/TV at the 4th week by mildly suppressing bone erosion without reducing bone formation, and it restored cancellous BV/TV and increased percentage of Ct Ar at the 8th week by preventing a reduction in trabecular bone formation and mildly suppressing trabecular bone erosion and by strongly suppressing endocortical bone erosion, respectively. RIS restored only cancellous BV/TV at 8 weeks by strongly suppressing bone formation and bone erosion. Combined administration of ALF and RIS increased total tissue area of cortical bone at the 4th and 8th weeks by markedly increasing periosteal bone formation. The present study showed the efficacy of combined administration of ALF and RIS for the geometry of cortical bone in GC-treated rats.  相似文献   

18.
There are substantial changes in maternal skeletal dynamics during pregnancy, lactation, and after lactation. The purpose of this study was to correlate changes in cortical and cancellous bone mass, structure, and dynamics with mechanical properties during and after the first reproductive cycle in rats. Rats were mated and groups were taken at parturition, end of lactation and 8 wk after weaning, and were compared with age-matched, nulliparous controls. Measurements were taken on femoral cortical bone and lumbar vertebral body cancellous bone. At the end of pregnancy, there was an increase in cortical periosteal bone formation and an increase in cortical volume, but a suppression of turnover in cancellous bone with no change in cancellous or cortical mechanical properties. Lactation was associated with a decrease in cortical and cancellous bone strength with a decrease in bone volume, but an increase in turnover on cancellous and endocortical surfaces. After lactation, there was a partial or full restoration of mechanical properties. This study demonstrates substantial changes in bone mechanics that correlate with changes in bone structure and dynamics during the first reproductive cycle in rats. The greatest changes were observed during the lactation period with partial or full recovery in the postlactational period.  相似文献   

19.
Errors induced by off-axis measurement of the elastic properties of bone   总被引:1,自引:0,他引:1  
Misalignment between the axes of measurement and the material symmetry axes of bone causes error in anisotropic elastic property measurements. Measurements of Poisson's ratio were strongly affected by misalignment errors. The mean errors in the measured Young's moduli were 9.5 and 1.3 percent for cancellous and cortical bone, respectively, at a misalignment angle of 10 degrees. Mean errors of 1.1 and 5.0 percent in the measured shear moduli for cancellous and cortical bone, respectively, were found at a misalignment angle of 10 degrees. Although, cancellous bone tissue was assumed to have orthotropic elastic symmetry, the possibility of the greater symmetry of transverse isotropy was investigated. When the nine orthotropic elastic constants were forced to approximate the five transverse isotropic elastic constants, errors of over 60 percent were introduced. Therefore, it was concluded that cancellous bone is truly orthotropic and not transversely isotropic. A similar but less strong result for cortical bone tissue was obtained.  相似文献   

20.
Laminectomy and facetectomy are surgical techniques used for decompression of the cervical spinal stenosis. Recent in vitro and finite element studies have shown significant cervical spinal instability after performing these surgical techniques. However, the influence of degenerated cervical disk on the biomechanical responses of the cervical spine after these surgical techniques remains unknown. Therefore, a three-dimensional nonlinear finite element model of the human cervical spine (C2-C7) was created. Two types of disk degeneration grades were simulated. For each grade of disk degeneration, the intact as well as the two surgically altered models simulating C5 laminectomy with or without C5-C6 total facetectomies were exercised under flexion and extension. Intersegmental rotational motions, internal disk annulus, cancellous and cortical bone stresses were obtained and compared to the normal intact model. Results showed that the cervical rotational motion decreases with progressive disk degeneration. Decreases in the rotational motion due to disk degeneration were accompanied by higher cancellous and cortical bone stress. The surgically altered model showed significant increases in the rotational motions after laminectomies and facetectomies when compared to the intact model. However, the percentage increases in the rotational motions after various surgical techniques were reduced with progressive disk degeneration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号