首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We evaluated a whole genome amplification method—multiple displacement amplification (MDA)—as a means to conserve valuable nonhuman primate samples. We tested 148 samples from a variety of species and sample sources, including blood, tissue, cell-lines, plucked hair and noninvasively collected semen. To evaluate genotyping success and accuracy of MDA, we used routine genotyping methods, including short tandem repeat (STR) analysis, denaturing gradient gel electrophoresis (DGGE), Alu repeat analysis, direct sequencing, and nucleotide detection by tag-array minisequencing. We compared genotyping results from MDA products to genotypes generated from the original (non-MD amplified) DNA samples. All genotyping methods showed good results with the MDA products as a DNA template, and for some samples MDA improved genotyping success. We show that the MDA procedure has the potential to provide a long-lasting source of DNA for genetic studies, which would be highly valuable for the primate research field, in which genetic resources are limited and for other species in which similar sampling constraints apply.  相似文献   

2.

Background

Genome-wide profiling of single-nucleotide polymorphisms is receiving increasing attention as a method of pre-implantation genetic diagnosis in humans and of commercial genotyping of pre-transfer embryos in cattle. However, the very small quantity of genomic DNA in biopsy material from early embryos poses daunting technical challenges. A reliable whole-genome amplification (WGA) procedure would greatly facilitate the procedure.

Results

Several PCR-based and non-PCR based WGA technologies, namely multiple displacement amplification, quasi-random primed library synthesis followed by PCR, ligation-mediated PCR, and single-primer isothermal amplification were tested in combination with different DNA extractions protocols for various quantities of genomic DNA inputs. The efficiency of each method was evaluated by comparing the genotypes obtained from 15 cultured cells (representative of an embryonic biopsy) to unamplified reference gDNA. The gDNA input, gDNA extraction method and amplification technology were all found to be critical for successful genome-wide genotyping. The selected WGA platform was then tested on embryo biopsies (n = 226), comparing their results to that of biopsies collected after birth. Although WGA inevitably leads to a random loss of information and to the introduction of erroneous genotypes, following genomic imputation the resulting genetic index of both sources of DNA were highly correlated (r = 0.99, P<0.001).

Conclusion

It is possible to generate high-quality DNA in sufficient quantities for successful genome-wide genotyping starting from an early embryo biopsy. However, imputation from parental and population genotypes is a requirement for completing and correcting genotypic data. Judicious selection of the WGA platform, careful handling of the samples and genomic imputation together, make it possible to perform extremely reliable genomic evaluations for pre-transfer embryos.

Electronic supplementary material

The online version of this article (doi:10.1186/1471-2164-15-889) contains supplementary material, which is available to authorized users.  相似文献   

3.
DNA quantity can be a hindrance in ecological and evolutionary research programmes due to a range of factors including endangered status of target organisms, available tissue type, and the impact of field conditions on preservation methods. A potential solution to low‐quantity DNA lies in whole genome amplification (WGA) techniques that can substantially increase DNA yield. To date, few studies have rigorously examined sequence bias that might result from WGA and next‐generation sequencing of nonmodel taxa. To address this knowledge deficit, we use multiple displacement amplification (MDA) and double‐digest RAD sequencing on the grey mouse lemur (Microcebus murinus) to quantify bias in genome coverage and SNP calls when compared to raw genomic DNA (gDNA). We focus our efforts in providing baseline estimates of potential bias by following manufacturer's recommendations for starting DNA quantities (>100 ng). Our results are strongly suggestive that MDA enrichment does not introduce systematic bias to genome characterization. SNP calling between samples when genotyping both de‐novo and with a reference genome are highly congruent (>98%) when specifying a minimum threshold of 20X stack depth to call genotypes. Relative genome coverage is also similar between MDA and gDNA, and allelic dropout is not observed. SNP concordance varies based on coverage threshold, with 95% concordance reached at ~12X coverage genotyping de‐novo and ~7X coverage genotyping with the reference genome. These results suggest that MDA may be a suitable solution for next‐generation molecular ecological studies when DNA quantity would otherwise be a limiting factor.  相似文献   

4.

Background

Whole genome amplification (WGA) promises to eliminate practical molecular genetic analysis limitations associated with genomic DNA (gDNA) quantity. We evaluated the performance of multiple displacement amplification (MDA) WGA using gDNA extracted from lymphoblastoid cell lines (N = 27) with a range of starting gDNA input of 1–200 ng into the WGA reaction. Yield and composition analysis of whole genome amplified DNA (wgaDNA) was performed using three DNA quantification methods (OD, PicoGreen® and RT-PCR). Two panels of N = 15 STR (using the AmpFlSTR® Identifiler® panel) and N = 49 SNP (TaqMan®) genotyping assays were performed on each gDNA and wgaDNA sample in duplicate. gDNA and wgaDNA masses of 1, 4 and 20 ng were used in the SNP assays to evaluate the effects of DNA mass on SNP genotyping assay performance. A total of N = 6,880 STR and N = 56,448 SNP genotype attempts provided adequate power to detect differences in STR and SNP genotyping performance between gDNA and wgaDNA, and among wgaDNA produced from a range of gDNA templates inputs.

Results

The proportion of double-stranded wgaDNA and human-specific PCR amplifiable wgaDNA increased with increased gDNA input into the WGA reaction. Increased amounts of gDNA input into the WGA reaction improved wgaDNA genotyping performance. Genotype completion or genotype concordance rates of wgaDNA produced from all gDNA input levels were observed to be reduced compared to gDNA, although the reduction was not always statistically significant. Reduced wgaDNA genotyping performance was primarily due to the increased variance of allelic amplification, resulting in loss of heterozygosity or increased undetermined genotypes. MDA WGA produces wgaDNA from no template control samples; such samples exhibited substantial false-positive genotyping rates.

Conclusion

The amount of gDNA input into the MDA WGA reaction is a critical determinant of genotyping performance of wgaDNA. At least 10 ng of lymphoblastoid gDNA input into MDA WGA is required to obtain wgaDNA TaqMan® SNP assay genotyping performance equivalent to that of gDNA. Over 100 ng of lymphoblastoid gDNA input into MDA WGA is required to obtain optimal STR genotyping performance using the AmpFlSTR® Identifiler® panel from wgaDNA equivalent to that of gDNA.
  相似文献   

5.
Whole genome amplification (WGA) procedures such as primer extension preamplification (PEP) or multiple displacement amplification (MDA) have the potential to provide an unlimited source of DNA for large-scale genetic studies. We have performed a quantitative evaluation of PEP and MDA for genotyping single nucleotide polymorphisms (SNPs) using multiplex, four-color fluorescent minisequencing in a microarray format. Forty-five SNPs were genotyped and the WGA methods were evaluated with respect to genotyping success, signal-to-noise ratios, power of genotype discrimination, yield and imbalanced amplification of alleles in the MDA product. Both PEP and MDA products provided genotyping results with a high concordance to genomic DNA. For PEP products the power of genotype discrimination was lower than for MDA due to a 2-fold lower signal-to-noise ratio. MDA products were indistinguishable from genomic DNA in all aspects studied. To obtain faithful representation of the SNP alleles at least 0.3 ng DNA should be used per MDA reaction. We conclude that the use of WGA, and MDA in particular, is a highly promising procedure for producing DNA in sufficient amounts even for genome wide SNP mapping studies.  相似文献   

6.
Multiple displacement amplification (MDA) has emerged as a promising new method of whole genome amplification (WGA) with the potential to generate virtually unlimited genome-equivalent DNA from only a small amount of seed DNA. To date, genome-wide high marker density assessments of MDA–DNA have focussed mainly upon suitability for single nucleotide polymorphism (SNP) genotyping applications. Suitability for short tandem repeat (STR) genotyping has not been investigated in great detail, despite their inherent instability during DNA replication, and the obvious challenge that this presents to WGA techniques. Here, we aimed to assess the applicability of MDA in STR genotyping by conducting a genome-wide scan of 768 STR markers for MDAs of 15 high quality genomic DNAs. We found that MDA genotyping call and accuracy rates were only marginally lower than for genomic DNA. Pooling of three replicate MDAs resulted in a small increase in both call rate and genotyping accuracy. We identified 34 STRs (4.4% of total markers) of which five essentially failed with MDA samples, and 29 of which showed elevated genotyping failures/discrepancies in the MDAs. We emphasise the importance of DNA and MDA quality checks, and the use of appropriate controls to identify problematic STR markers.  相似文献   

7.

Background

Rolling circle amplification of ligated probes is a simple and sensitive means for genotyping directly from genomic DNA. SNPs and mutations are interrogated with open circle probes (OCP) that can be circularized by DNA ligase when the probe matches the genotype. An amplified detection signal is generated by exponential rolling circle amplification (ERCA) of the circularized probe. The low cost and scalability of ligation/ERCA genotyping makes it ideally suited for automated, high throughput methods.

Results

A retrospective study using human genomic DNA samples of known genotype was performed for four different clinically relevant mutations: Factor V Leiden, Factor II prothrombin, and two hemochromatosis mutations, C282Y and H63D. Greater than 99% accuracy was obtained genotyping genomic DNA samples from hundreds of different individuals. The combined process of ligation/ERCA was performed in a single tube and produced fluorescent signal directly from genomic DNA in less than an hour. In each assay, the probes for both normal and mutant alleles were combined in a single reaction. Multiple ERCA primers combined with a quenched-peptide nucleic acid (Q-PNA) fluorescent detection system greatly accellerated the appearance of signal. Probes designed with hairpin structures reduced misamplification. Genotyping accuracy was identical from either purified genomic DNA or genomic DNA generated using whole genome amplification (WGA). Fluorescent signal output was measured in real time and as an end point.

Conclusions

Combining the optimal elements for ligation/ERCA genotyping has resulted in a highly accurate single tube assay for genotyping directly from genomic DNA samples. Accuracy exceeded 99 % for four probe sets targeting clinically relevant mutations. No genotypes were called incorrectly using either genomic DNA or whole genome amplified sample.  相似文献   

8.

Background

Sustainable DNA resources and reliable high-throughput genotyping methods are required for large-scale, long-term genetic association studies. In the genetic dissection of common disease it is now recognised that thousands of samples and hundreds of thousands of markers, mostly single nucleotide polymorphisms (SNPs), will have to be analysed. In order to achieve these aims, both an ability to boost quantities of archived DNA and to genotype at low costs are highly desirable. We have investigated Φ29 polymerase Multiple Displacement Amplification (MDA)-generated DNA product (MDA product), in combination with highly multiplexed BeadArray? genotyping technology. As part of a large-scale BeadArray genotyping experiment we made a direct comparison of genotyping data generated from MDA product with that from genomic DNA (gDNA) templates.

Results

Eighty-six MDA product and the corresponding 86 gDNA samples were genotyped at 345 SNPs and a concordance rate of 98.8% was achieved. The BeadArray sample exclusion rate, blind to sample type, was 10.5% for MDA product compared to 5.8% for gDNA.

Conclusions

We conclude that the BeadArray technology successfully produces high quality genotyping data from MDA product. The combination of these technologies improves the feasibility and efficiency of mapping common disease susceptibility genes despite limited stocks of gDNA samples.  相似文献   

9.
Current microarray technology allows researchers to genotype a large number of SNPs with relatively small amounts of DNA. Nevertheless, researchers and clinicians still frequently face the problem of acquiring enough high-quality DNA for analysis. Whole-genome amplification (WGA) methods offer a solution for this problem, and earlier studies have shown that WGA samples perform reasonably well in small-scale genetic analyses (e.g. Affymetrix 10K array). To determine the performance of WGA products on a large-scale genotyping array, we compared the Affymetrix 250K array genotyping results of genomic DNA and their WGA products from four individuals. Our results indicate that WGA product performs well on the 250K array compared to genomic DNA, especially when using the BRLMM calling algorithm. WGA samples have high call rates (97.5% on average, compared to 99.4% for genomic DNA) and excellent concordance rates with their corresponding genomic DNA samples (98.7% on average). In addition, no apparent systematic genomic amplification bias can be detected. This study demonstrates that, although there is a slight decrease in the total call rates, WGA methods provide a reliable approach for increasing the amount of DNA samples for use with a common SNP genotyping array.  相似文献   

10.

Background

Next-generation sequencing sample preparation requires nanogram to microgram quantities of DNA; however, many relevant samples are comprised of only a few cells. Genomic analysis of these samples requires a whole genome amplification method that is unbiased and free of exogenous DNA contamination. To address these challenges we have developed protocols for the production of DNA-free consumables including reagents and have improved upon multiple displacement amplification (iMDA).

Results

A specialized ethylene oxide treatment was developed that renders free DNA and DNA present within Gram positive bacterial cells undetectable by qPCR. To reduce DNA contamination in amplification reagents, a combination of ion exchange chromatography, filtration, and lot testing protocols were developed. Our multiple displacement amplification protocol employs a second strand-displacing DNA polymerase, improved buffers, improved reaction conditions and DNA free reagents. The iMDA protocol, when used in combination with DNA-free laboratory consumables and reagents, significantly improved efficiency and accuracy of amplification and sequencing of specimens with moderate to low levels of DNA. The sensitivity and specificity of sequencing of amplified DNA prepared using iMDA was compared to that of DNA obtained with two commercial whole genome amplification kits using 10 fg (~1-2 bacterial cells worth) of bacterial genomic DNA as a template. Analysis showed >99% of the iMDA reads mapped to the template organism whereas only 0.02% of the reads from the commercial kits mapped to the template. To assess the ability of iMDA to achieve balanced genomic coverage, a non-stochastic amount of bacterial genomic DNA (1 pg) was amplified and sequenced, and data obtained were compared to sequencing data obtained directly from genomic DNA. The iMDA DNA and genomic DNA sequencing had comparable coverage 99.98% of the reference genome at ≥1X coverage and 99.9% at ≥5X coverage while maintaining both balance and representation of the genome.

Conclusions

The iMDA protocol in combination with DNA-free laboratory consumables, significantly improved the ability to sequence specimens with low levels of DNA. iMDA has broad utility in metagenomics, diagnostics, ancient DNA analysis, pre-implantation embryo screening, single-cell genomics, whole genome sequencing of unculturable organisms, and forensic applications for both human and microbial targets.  相似文献   

11.

Background

Until recently, only a small number of low- and mid-throughput methods have been used for single nucleotide polymorphism (SNP) discovery and genotyping in grapevine (Vitis vinifera L.). However, following completion of the sequence of the highly heterozygous genome of Pinot Noir, it has been possible to identify millions of electronic SNPs (eSNPs) thus providing a valuable source for high-throughput genotyping methods.

Results

Herein we report the first application of the SNPlex? genotyping system in grapevine aiming at the anchoring of an eukaryotic genome. This approach combines robust SNP detection with automated assay readout and data analysis. 813 candidate eSNPs were developed from non-repetitive contigs of the assembled genome of Pinot Noir and tested in 90 progeny of Syrah × Pinot Noir cross. 563 new SNP-based markers were obtained and mapped. The efficiency rate of 69% was enhanced to 80% when multiple displacement amplification (MDA) methods were used for preparation of genomic DNA for the SNPlex assay.

Conclusion

Unlike other SNP genotyping methods used to investigate thousands of SNPs in a few genotypes, or a few SNPs in around a thousand genotypes, the SNPlex genotyping system represents a good compromise to investigate several hundred SNPs in a hundred or more samples simultaneously. Therefore, the use of the SNPlex assay, coupled with whole genome amplification (WGA), is a good solution for future applications in well-equipped laboratories.  相似文献   

12.
Genetic characterization of field isolates and clinical specimens of filarial nematodes is often limited by a shortage of DNA; therefore, we evaluated a multiple displacement amplification (MDA) based whole genome amplification method. The quality of amplified DNA was examined by conventional PCR, real-time PCR, and DNA hybridization. MDA of 5.0 ng of adult Brugia malayi DNA and one-fifteenth of the DNA isolated from a single microfilaria resulted in 6.3 and 4.2 μg of amplified DNA, respectively. Amplified DNA was equivalent to native genomic DNA for hybridization to B. malayi BAC library clones or to an oligonucleotide microarray with approximately 18,000 filarial DNA sequences. MDA is useful for whole genome amplification of filarial DNA from very small amounts of starting material. This technology will permit detailed studies of genetic diversity that were not previously feasible.  相似文献   

13.
Abstract

When cytobrush buccal cell samples have been collected as a genomic DNA (gDNA) source for an epidemiological study, whole genome amplification (WGA) can be critical to maintain sufficient DNA for genotyping. We evaluated REPLI-g? WGA using gDNA from two paired cytobrushes (cytobush ‘A’ kept in a cell lysis buffer, and ‘B’ dried and kept at room temperature for 3 days, and frozen until DNA extraction) in a pilot study (n=21), and from 144 samples collected by mail in a breast cancer study. WGA success was assessed as the per cent completion/concordance of STR/SNP genotypes. Locus amplification bias was assessed using quantitative PCR of 23 human loci. The pilot study showed > 98% completion but low genotype concordance between cytobrush wgaDNA and paired blood gDNA (82% and 84% for cytobrushes A and B, respectively). Substantial amplification bias was observed with significantly lower human gDNA amplification from cytobrush B than A. Using cytobrush gDNA samples from the breast cancer study (n =20), an independent laboratory demonstrated that increasing template gDNA to the REPLI-g reaction improved genotype performance for 49 SNPs; however, average completion and concordance remained below 90%. To reduce genotype misclassification when cytobrush wgaDNA is used, inclusion of paired gDNA/wgaDNA and/or duplicate wgaDNA samples is critical to monitor data quality.  相似文献   

14.
Low-biomass samples from nitrate and heavy metal contaminated soils yield DNA amounts that have limited use for direct, native analysis and screening. Multiple displacement amplification (MDA) using 29 DNA polymerase was used to amplify whole genomes from environmental, contaminated, subsurface sediments. By first amplifying the genomic DNA (gDNA), biodiversity analysis and gDNA library construction of microbes found in contaminated soils were made possible. The MDA method was validated by analyzing amplified genome coverage from approximately five Escherichia coli cells, resulting in 99.2% genome coverage. The method was further validated by confirming overall representative species coverage and also an amplification bias when amplifying from a mix of eight known bacterial strains. We extracted DNA from samples with extremely low cell densities from a U.S. Department of Energy contaminated site. After amplification, small-subunit rRNA analysis revealed relatively even distribution of species across several major phyla. Clone libraries were constructed from the amplified gDNA, and a small subset of clones was used for shotgun sequencing. BLAST analysis of the library clone sequences showed that 64.9% of the sequences had significant similarities to known proteins, and “clusters of orthologous groups” (COG) analysis revealed that more than half of the sequences from each library contained sequence similarity to known proteins. The libraries can be readily screened for native genes or any target of interest. Whole-genome amplification of metagenomic DNA from very minute microbial sources, while introducing an amplification bias, will allow access to genomic information that was not previously accessible.  相似文献   

15.
Whole-genome amplification (WGA) methods were adopted for single-nucleotide-polymorphism (SNP) typing to minimize the amount of genomic DNA that has to be used in typing for thousands of different SNPs in large-scale studies; 5-10 ng of genomic DNA was amplified by a WGA method (improved primer-extension-preamplification-polymerase chain reaction (I-PEP-PCR), degenerated oligonucleotide primer-PCR (DOP-PCR), or multiple displacement amplification (MDA)). Using 1/100 to 1/500 amounts of the whole-genome-amplified products as templates, subsequent analyses were successfully performed. SNPs were genotyped by the sequence-specific primer (SSP)-PCR method followed by fluorescence correlation spectroscopy (FCS). The typing results were evaluated for four different SNPs on tumor necrosis factor receptor 1 and 2 genes (TNFR1 and TNFR2). The genotypes determined by the SSP-FCS method using the WGA products were 100% in concordance with those determined by nucleotide sequencing using genomic DNAs. We have already carried out typing of more than 300 different SNPs and are currently performing 7,500-10,000 typings per day using WGA samples from patients with several common diseases. WGA coupled with FCS allows specific and high-throughput genotyping of thousands of samples for thousands of different SNPs.  相似文献   

16.
Conservation and population genetic studies are sometimes hampered by insufficient quantities of high quality DNA. One potential way to overcome this problem is through the use of whole genome amplification (WGA) kits. We performed rolling circle WGA on DNA obtained from matched hair and tissue samples of North American red squirrels (Tamiasciurus hudsonicus). Following polymerase chain reaction (PCR) at four microsatellite loci, we compared genotyping success for DNA from different source tissues, both pre‐ and post‐WGA. Genotypes obtained with tissue were robust, whether or not DNA had been subjected to WGA. DNA extracted from hair produced results that were largely concordant with matched tissue samples, although amplification success was reduced and some allelic dropout was observed. WGA of hair samples resulted in a low genotyping success rate and an unacceptably high rate of allelic dropout and genotyping error. The problem was not rectified by conducting PCR of WGA hair samples in triplicate. Therefore, we conclude that WGA is only an effective method of enhancing template DNA quantity when the initial sample is from high‐yield material.  相似文献   

17.

Background

Large epidemiologic studies have the potential to make valuable contributions to the assessment of gene-environment interactions because they prospectively collected detailed exposure data. Some of these studies, however, have only serum or plasma samples as a low quantity source of DNA.

Methods

We examined whether DNA isolated from serum can be used to reliably and accurately genotype single nucleotide polymorphisms (SNPs) using Sequenom multiplex SNP genotyping technology. We genotyped 81 SNPs using samples from 158 participants in the NYU Women’s Health Study. Each participant had DNA from serum and at least one paired DNA sample isolated from a high quality source of DNA, i.e. clots and/or cell precipitates, for comparison.

Results

We observed that 60 of the 81 SNPs (74%) had high call frequencies (≥95%) using DNA from serum, only slightly lower than the 85% of SNPs with high call frequencies in DNA from clots or cell precipitates. Of the 57 SNPs with high call frequencies for serum, clot, and cell precipitate DNA, 54 (95%) had highly concordant (>98%) genotype calls across all three sample types. High purity was not a critical factor to successful genotyping.

Conclusions

Our results suggest that this multiplex SNP genotyping method can be used reliably on DNA from serum in large-scale epidemiologic studies.  相似文献   

18.
The multiple displacement amplification (MDA) method, which relies on isothermal DNA amplification using the DNA polymerase of the bacteriophage phi29, was recently developed for high-performance, whole-genome amplification (WGA). The objective of the present study was to determine whether a target sequence could be successfully amplified by conventional PCR when the genomic DNA of a single Day-7 porcine blastocyst (derived from SCNT of a gene-engineered fibroblast) was amplified by the MDA method and used as a template. The yield of double-stranded DNA was 103.5 ± 16.0 ng/embryo (range, 75-125), as assessed by a PocoGreen assay. However, non-specific products (20 ± 5 ng/tube) were also generated, even in the negative control. Thus, ∼81% of the 103.5 ng (84 ng) of amplified DNA was estimated to be porcine sequences (2.2 × 103-fold enrichment). In addition, PCR confirmed the presence of transgenes, as well as endogenous α-1,3-galactosyltransferase and homeobox Nanog genes in all embryos. Sequencing of the amplified products verified the fidelity of this system. In conclusion, the MDA-mediated WGA, which was simple, inexpensive, and did not require a thermal cycler, could be a powerful tool for multiple genomic analyses of individual early porcine embryos.  相似文献   

19.
Major efforts are underway to systematically define the somatic and germline genetic variations causally associated with disease. Genome-wide genetic analysis of actual clinical samples is, however, limited by the paucity of genomic DNA available. Here we have tested the fidelity and genome representation of 29 polymerase-based genome amplification (29MDA) using direct sequencing and high density oligonucleotide arrays probing >10000 SNP alleles. Genome representation was comprehensive and estimated to be 99.82% complete, although six regions encompassing a maximum of 5.62 Mb failed to amplify. There was no degradation in the accuracy of SNP genotyping and, in direct sequencing experiments sampling 500 000 bp, the estimated error rate (9.5 × 10–6) was the same as in paired unamplified samples. The detection of cancer-associated loss of heterozygosity and copy number changes, including homozygous deletion and gene amplification, were similarly robust. These results suggest that 29MDA yields high fidelity, near-complete genome representation suitable for high resolution genetic analysis.  相似文献   

20.

Background  

Bacterial and cellular genotyping is becoming increasingly important in the diagnosis of infectious diseases. However, difficulties in obtaining sufficient amount of bacterial and cellular DNA extracted from the same human biopsy specimens is often a limiting factor. In this study, total DNA (host and bacterial DNA) was isolated from minute amounts of gastric biopsy specimens and amplified by means of whole genome amplification using the multiple displacement amplification (MDA) technique. Subsequently, MDA-DNA was used for concurrent Helicobacter pylori and human host cellular DNA genotyping analysis using PCR-based methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号