首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 9 毫秒
1.
The diversity and dynamics of Legionella species along a French river watershed subject to different thermal and wastewater discharges during an annual cycle were assessed by 16S rRNA gene sequencing and by a fingerprint technique, single-strand conformation polymorphism. A high diversity of Legionella spp. was observed at all the sampling sites, and the dominant Legionella clusters identified were most closely related to uncultured bacteria. The monthly monitoring revealed that Legionella sp. diversity changes were linked only to season at the wastewater site whereas there was some evidence for anthropogenic effects on Legionella sp. diversity downstream of the thermal bath. Quantification of Legionella pneumophila and Legionella spp. by culture and quantitative PCR (qPCR) was performed. Whereas only L. pneumophila was quantified on culture media, the qPCR assay revealed that Legionella spp. were ubiquitous and abundant from the pristine source of the river to the downstream sampling sites. These results suggest that Legionella spp. may be present at significant concentrations in many more freshwater environments than previously thought, highlighting the need for further ecological studies and culturing efforts.  相似文献   

2.
M Koide  A Saito  N Kusano    F Higa 《Applied microbiology》1993,59(6):1943-1946
The presence of Legionella spp. in cooling tower water was investigated by using the polymerase chain reaction. Total Legionella spp. detection was performed with 20-mer 5S rRNA complementary DNA sequence primers, and specific Legionella pneumophila detection was performed with 20-mer and then 21-mer macrophage infectivity potentiator gene sequence primers. Of 27 cooling tower water samples, 25 were positive for Legionella spp., and 14 of these contained L. pneumophila.  相似文献   

3.
Legionella species are frequently detected in hot water systems, attached to the surface as a biofilm. In this work, the dynamics of Legionella spp. and diverse bacteria and eukarya associated together in the biofilm, coming from a pilot scale 1 system simulating a real hot water system, were investigated throughout 6 months after two successive heat shock treatments followed by three successive chemical treatments. Community structure was assessed by a fingerprint technique, single-strand conformation polymorphism (SSCP). In addition, the diversity and dynamics of Legionella and eukarya were investigated by small-subunit (SSU) ribosomal cloning and sequencing. Our results showed that pathogenic Legionella species remained after the heat shock and chemical treatments (Legionella pneumophila and Legionella anisa, respectively). The biofilm was not removed, and the bacterial community structure was transitorily affected by the treatments. Moreover, several amoebae had been detected in the biofilm before treatments (Thecamoebae sp., Vannella sp., and Hartmanella vermiformis) and after the first heat shock treatment, but only H. vermiformis remained. However, another protozoan affiliated with Alveolata, which is known as a host cell for Legionella, dominated the eukaryal species after the second heat shock and chemical treatment tests. Therefore, effective Legionella disinfection may be dependent on the elimination of these important microbial components. We suggest that eradicating Legionella in hot water networks requires better study of bacterial and eukaryal species associated with Legionella in biofilms.  相似文献   

4.
Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, P.R., were assayed for various Legionella spp. and serogroups by using direct immunofluorescence. Several water quality parameters were also measured for each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable organisms. Legionella pneumophila serogroups 1 to 6, L. bozemanii, L. micdadei, L. dumoffii, and L. gormanii were observed in at least one of the cooling towers. L. pneumophila was the most abundant species; its density reached 10(5) cells per ml, which is within the range that is considered potentially pathogenic to humans. A significantly higher density of L. pneumophila was observed in the cooling tower water that was not being treated with biocides. Percent respiration (INT) and total cell activity (acridine orange direct count) were inversely correlated with bacterial density. This study demonstrates that Legionella spp. are present in tropical air-conditioning cooling systems and that, without continuous biocide treatment, they may reach densities that present a health risk.  相似文献   

5.
Legionella spp. in Puerto Rico cooling towers.   总被引:1,自引:1,他引:0       下载免费PDF全文
Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, P.R., were assayed for various Legionella spp. and serogroups by using direct immunofluorescence. Several water quality parameters were also measured for each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable organisms. Legionella pneumophila serogroups 1 to 6, L. bozemanii, L. micdadei, L. dumoffii, and L. gormanii were observed in at least one of the cooling towers. L. pneumophila was the most abundant species; its density reached 10(5) cells per ml, which is within the range that is considered potentially pathogenic to humans. A significantly higher density of L. pneumophila was observed in the cooling tower water that was not being treated with biocides. Percent respiration (INT) and total cell activity (acridine orange direct count) were inversely correlated with bacterial density. This study demonstrates that Legionella spp. are present in tropical air-conditioning cooling systems and that, without continuous biocide treatment, they may reach densities that present a health risk.  相似文献   

6.
Aims:  To determine the incidence of multiple antibiotic-resistant strains of the emergent human pathogens Legionella pneumophila , Pseudomonas aeruginosa and mesophilic Aeromonas species among those isolated from water reservoirs and industrial cooling systems.
Methods and Results:  Water from four natural water reservoirs and four industrial cooling towers was sampled for 1 year period. The total heterotrophs, mesophilic Aeromonas , Pseudomonas spp. and Legionella spp. counts were performed as recommended by standard procedures, and the sensitivity of the isolates to 27 antibiotics was tested. A total of 117 Aeromonas , 60 P. aeruginosa and 15  L. pneumophila strains were isolated and identified by means of biochemical tests and DNA probes. 46·4% of Aeromonas , and 100% of P. aeruginosa isolates presented multiple resistance. Legionella pneumophila strains were generally sensitive to the drugs used.
Conclusions:  Antibiotic-resistant pathogenic bacteria belonging to P. aeruginosa and mesophilic Aeromonas species are common in natural aquatic environments. Thus, the risk of waterborne diseases owing to domestic and industrial uses of freshwater should be re-examined from the increase of bacterial resistance point of view.
Significance and Impact of the Study:  These data confirm the emergence of bacteria resistant to antibiotics in aquatic environments.  相似文献   

7.
The presence of high levels of Legionella pneumophila in man-made aquatic systems correlates with the incidence of nosocomial Legionnaires' disease. This requires a rapid, reliable, and sensitive quantification of L. pneumophila concentrations in suspected water systems. In this research, a homologous competitor was developed and evaluated in a L. pneumophila competitive polymerase chain reaction (cPCR) to quantify this human pathogen in a quick, cost-effective, and reliable way. Accuracy of cPCR was evaluated by analyzing cooling tower and tap water samples spiked with known concentrations of L. pneumophila bacteria, in parallel with the standard culture method. Legionella pneumophila amounts detected and calculated from cPCR and culture correlated very well: r = 0.998, P = 0.002 for tap water and r = 0.990, P = 0.009 for cooling tower water. Nevertheless, for both kinds of water samples, mean numbers of L. pneumophila calculated from cPCR results were always higher than those obtained by culture. This study makes it clear that the rapid, sensitive, and cost-effective L. pneumophila cPCR is a promising alternative to the standard time-consuming culture method and expensive real-time PCR to enumerate L. pneumophila bacteria in environmental water samples.  相似文献   

8.
The occurrence and viable counts of Legionella pneumophila in acid-treated water samples of 62 cooling towers on the main island of Japan were determined by inoculating them onto plates of Wadowsky-Yee-Okuda (WYO) agar medium. WYO plate cultures of 39 (63%) of the samples yielded L. pneumophila with viable counts ranging from 10 to 10(4) colony-forming units per 100 ml. Of the L. pneumophila isolates, 157 were serologically identified as serogroup 1, and the remaining 21 were agglutinated by serogroup 3 (2 strains) and serogroup 6 (19 strains) antisera. In each culture-positive water sample, the pH and the number of other bacteria were found not be statistically significantly correlated with the viable counts of L. pneumophila. However, a higher rate of recovery of L. pneumophila was obtained with the water samples with a smaller number of other bacteria. Practical use of commercially available antialgal or antimicrobial agents was found not to be significantly effective for controlling the occurrence and growth of L. pneumophila in cooling tower water.  相似文献   

9.
Cooling towers are considered to be man-made amplifiers of Legionella spp. Thus, the proper maintenance and choice of biocides is important. The only biocidal measure that has thus far been shown to be effective in field tests is the judicious use of chlorination. Perturbation studies with 1-bromo-3-chloro-5, 5-dimethylhydantoin (Bromicide; Great Lakes Chemical Corp., West Lafayette, Ind.) (BCD) were conducted on an industrial cooling tower shown to contain Legionella pneumophila. At the concentrations recommended by the manufacturer, neither the density nor the activity of L. pneumophila was affected. At comcentrations greater than 2.0 ppm (2.0 micorgram/ml) free of residual, BCD was not effective in reducing L. pneumophila to source water concentrations, nor was it effective in reducing the 2-p-iodophenyl-3-p-nitrophenyl-5-phenyl tetrazolium chloride activity of the bacterium in situ. The data indicate that at concentrations up to 2.0 ppm, BCD is not effective in these tower studies.  相似文献   

10.
军团菌属(Legionela)自1971年确定以来,现已有39个成员。军团菌属主要分布于供水系统中,如空调冷却塔水和浴池淋浴水中。我们曾于1994年从北京某宾馆冷却塔水中分离出一株可疑军团菌,但因缺乏标准抗血清而未能定种。由于核酸分析技术和细菌鉴定观念上进步,使我们能根据16SrDNA序列比较推测细菌间进化关系,并进而对未知细菌进行鉴定和检测。我们用以16SrDNA为靶序列的PCR和测定鉴定,确定了该分离株为橡树岭军团菌(L.oakridgensis)。  相似文献   

11.
Using fluorescence in situ hybridization to detect bacterial groups has several inherent limitations. DNA probes are generally used, targeting sites on the 16S rRNA. However, much of the 16S rRNA is highly conserved, with variable regions often located in inaccessible areas where secondary structures can restrict probe access. Here, we describe the use of peptide nucleic acid (PNA) probes as a superior alternative to DNA probes, especially when used for environmental samples. A complex bacterial genus (Legionella) was studied, and two probes were designed, one to detect all species and one targeted to Legionella pneumophila. These probes were developed from existing sequences and are targeted to low-binding-affinity sites on the 16S rRNA. In total, 47 strains of Legionella were tested. In all cases, the Legionella spp. PNA probe labeled cells strongly but did not bind to any non-Legionella species. Likewise, the specific L. pneumophila PNA probe labeled only strains of L. pneumophila. By contrast, the equivalent DNA probes performed poorly. To assess the applicability of this method for use on environmental samples, drinking-water biofilms were spiked with a known concentration of L. pneumophila bacteria. Quantifications of the L. pneumophila bacteria were compared using PNA hybridization and standard culture methods. The culture method quantified only 10% of the number of L. pneumophila bacteria found by PNA hybridization. This illustrates the value of this method for use on complex environmental samples, especially where cells may be in a viable but noncultivable state.  相似文献   

12.
Cooling towers are considered to be man-made amplifiers of Legionella spp. Thus, the proper maintenance and choice of biocides is important. The only biocidal measure that has thus far been shown to be effective in field tests is the judicious use of chlorination. Perturbation studies with 1-bromo-3-chloro-5, 5-dimethylhydantoin (Bromicide; Great Lakes Chemical Corp., West Lafayette, Ind.) (BCD) were conducted on an industrial cooling tower shown to contain Legionella pneumophila. At the concentrations recommended by the manufacturer, neither the density nor the activity of L. pneumophila was affected. At comcentrations greater than 2.0 ppm (2.0 micorgram/ml) free of residual, BCD was not effective in reducing L. pneumophila to source water concentrations, nor was it effective in reducing the 2-p-iodophenyl-3-p-nitrophenyl-5-phenyl tetrazolium chloride activity of the bacterium in situ. The data indicate that at concentrations up to 2.0 ppm, BCD is not effective in these tower studies.  相似文献   

13.
摘要:目的 了解2006?2016年辽宁地区集中空调冷却水中军团菌携带毒力岛基因情况及其致病性。方法 根据GenBank公布的嗜肺军团菌核苷酸序列设计和合成嗜肺军团菌种和毒力岛基因鉴定引物,采用PCR法对2006?2016年辽宁省各大公共场所委托及抽样检测中分离到的军团菌,进行了毒力岛基因组检测,并与血清型进行比较分析,其中嗜肺军团菌15株、非嗜肺军团菌8株。结果 标准菌株ATCC(33152)12个毒力岛基因全阳性;9株LP1型嗜肺军团菌分别检出9~11个毒力岛基因,6株LP2-14型嗜肺军团菌分别检出6~9个毒力岛基因,8株非嗜肺军团菌分别检出2~11个毒力岛基因。结论 辽宁地区军团菌广泛存在公共环境集中空调冷却系统中,以LP1型嗜肺军团菌居多,LP2-14型嗜肺军团菌与非嗜肺军团菌也普遍存在,而且所测菌株均携带毒力岛基因,是细菌感染性肺炎的重要隐患病源之一。  相似文献   

14.
嗜肺军团菌是引起社区获得性和医院内感染性肺炎的重要病原体,中央空调冷凝塔水系统是引发军团菌病的重要传染源,在国内外时有暴发流行,病死率较高。嗜肺军团菌的致病性与其毒力岛基因组密切相关。简要概述了嗜肺军团菌毒力岛、分子分型及其致病性。  相似文献   

15.
降雨对秦皇岛西浴场细菌总数和可培养菌群组成的影响   总被引:3,自引:0,他引:3  
【目的】研究降雨条件对浴场细菌总数和优势菌群组成的影响。【方法】2014年8月强降雨前后采集秦皇岛西浴场3个站位的海水样品,采用荧光显微镜计数法和平板计数法分别对细菌总数和可培养细菌总数进行计数;对群落结构组成进行分析,并对可培养细菌进行鉴定。【结果】雨前3个站位细菌总数和可培养细菌总数平均值分别为5.6×10~9 CFU/L和8.3×10~7 CFU/L,雨后分别为9.2×109 CFU/L和2.1×10~8 CFU/L。在可培养菌群中,变形菌门(Proteobacteria,雨前占80%,雨后占73%)是主要的微生物类群,其次为拟杆菌门(Bacteroides,雨前占12%,雨后占13%)、厚壁菌门(Firmicutes,雨前占7%,雨后占11%)等;肠杆菌属(Enterobacter spp.,21株)、海杆菌属(Marinobacter spp.,13株)、弓形菌属(Arcobacter spp.,13株)、假单胞菌属(Pseudomonas spp.,10株)、芽孢杆菌属(Bacillus spp.,10株)和弧菌属(Vibrio spp.,6株)为雨前可培养细菌优势属,而雨后可培养细菌优势属为肠杆菌属(22株)、海杆菌属(21株)、芽孢杆菌属(14株)、不动杆菌属(Acinetobacter spp.,11株)、假单胞菌属(9株)和弓形菌属(5株)等。【结论】降雨对细菌总数有显著的影响,同时降雨后浴场微生物群落结构发生了改变。  相似文献   

16.
A negative enrichment procedure was developed which was capable of isolating Legionella pneumophila directly from seeded air-conditioning cooling tower water onto laboratory media. This procedure was based on an 8-h incubation under conditions that were bactericidal to the indigenous water microflora but merely bacteriostatic to L. pneumophila.  相似文献   

17.
Multiplication of Legionella pneumophila in unsterilized tap water.   总被引:22,自引:17,他引:5       下载免费PDF全文
Naturally occurring Legionella pneumophila, an environmental isolate which had not been grown on artificial medium, was tested for the ability to multiply in tap water. A showerhead containing L. pneumophila and non-Legionellaceae bacteria was immersed in nonsterile tap water supplying this fixture. Also L. pneumophila and non-Legionellaceae bacteria were sedimented from tap water from a surgical intensive care unit. This bacterial suspension was inoculated into tap water from our laboratory. The legionellae in both suspensions multiplied in the tap water at 32, 37, and 42 degrees C. The non-Legionellaceae bacteria multiplied at 25, 32, and 37 degrees C. A water sample which was collected from the bottom of a hot water tank was found to contain L. pneumophila and non-Legionellaceae bacteria. These legionellae also multiplied when the water sample was incubated at 37 degrees C. These results indicate that L. pneumophila may multiply in warm water environments such as hot water plumbing fixtures, hot water tanks, and cooling towers.  相似文献   

18.
Waters in marine and freshwater areas of Puerto Rico were analyzed for the presence of Legionella spp. by direct fluorescent antibody assay with guinea pig confirmation. Several species, including L. bozemanii, L. dumoffii, L. gormanii, L. longbeachae, L. micdadei, and L. pneumophila, were widely distributed among all sites. Legionellaceae, including L. pneumophila, were found in high densities in water collected in the rain forest from epiphytes in trees 30 ft. (about 9.25 m) above the ground. Both interspecific and intersite variations were significant. L. pneumophila was the most abundant species at all sites, with average densities of 10(4) cells ml-1, very close to the range which is potentially pathogenic for humans. Densities of L. pneumophila were highest in sewage-contaminated coastal waters. These are the highest densities of Legionella spp. ever reported for marine habitats. Densities of L. pneumophila were positively correlated with concentrations of sulfates, phosphates, and pH. A survey of 88 fatal atypical pneumonia cases at a Puerto Rico hospital showed that 15% of the patients had L. pneumophila infections. This study establishes L. pneumophila as a relatively common cause of atypical pneumonia in Puerto Rico and suggests natural aquatic habitats as possible sources or reservoirs of pathogenic Legionella spp. in the tropics.  相似文献   

19.
AIMS: Investigation of the attachment and uptake of Legionella pneumophila by Acanthamoeba castellanii and Naegleria lovaniensis, as these are two critical steps in the subsequent bacterial survival in both amoeba hosts. METHODS AND RESULTS: Initially, the mode of Legionella uptake was examined using inhibitors of microfilament-dependent and receptor-mediated uptake phagocytosis. Secondly, the minimum saccharide structure to interfere with L. pneumophila uptake was determined by means of selected saccharides. Bacterial attachment and uptake by each of the amoeba species occurred through a receptor-mediated endocytosis, which required de novo synthesis of host proteins. Legionella pneumophila showed a high affinity to the alpha1-3D-mannobiose domain of the mannose-binding receptor located on A. castellanii. In contrast, L. pneumophila bacteria had a high affinity for the GalNAcbeta1-4Gal domain of the N-acetyl-D-galactosamine receptor of N. lovaniensis. CONCLUSIONS: Our data pointed to a remarkable adaptation of L. pneumophila to invade different amoeba hosts, as the uptake by both amoeba species is mediated by two different receptor families. SIGNIFICANCE AND IMPACT OF THE STUDY: The fact that L. pneumophila is taken up by two different amoeba species using different receptor families adds further complexity to the host-parasite interaction process, as 14 amoeba species are known to be appropriate Legionella hosts.  相似文献   

20.
We evaluated a ready-to-use real-time quantitative Legionella pneumophila PCR assay system by testing 136 hot-water-system samples collected from 55 sites as well as 49 cooling tower samples collected from 20 different sites, in parallel with the standard culture method. The PCR assay was reproducible and suitable for routine quantification of L. pneumophila. An acceptable correlation between PCR and culture results was obtained for sanitary hot-water samples but not for cooling tower samples. We also monitored the same L. pneumophila-contaminated cooling tower for 13 months by analyzing 104 serial samples. The culture and PCR results were extremely variable over time, but the curves were similar. The differences between the PCR and culture results did not change over time and were not affected by regular biocide treatment. This ready-to-use PCR assay for L. pneumophila quantification could permit more timely disinfection of cooling towers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号