首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到5条相似文献,搜索用时 0 毫秒
1.
The available physical and biological broadband radiometers designed to determine erythema-effective radiation do not show any response or over/underestimate the biologically effective radiation to a high extent in the ultraviolet (UV)A spectral region. The data presented in this paper demonstrate that the biological system used in this study is the first one to make possible measurements of erythema-effective radiation in the sun in the UVA and UVB spectral region. These measurements were performed with a spore-film filter system as well as with spectroradiometers. It was demonstrated that this biotechnological method could be used to determine exact values expressed as minimal erythemal dose (MED). The spore-film system was tested in various field campaigns performed in Germany and in Japan. The seasonal daily variation of UV radiation in Germany determined in the period November 1995 to December 1996 using the spore-film filter system in sunny conditions tallied well with model calculations. The daily dose in Germany measured with the spore-film system close to the summer solstice, in sunny conditions (20.45 MED), was approximately 20 times higher than the lowest value measured close to the winter solstice (0.82 MED), a result which was in accordance with model calculations. The data determined with the spore-film filter system in Sapporo and Naha, Japan, fitted to the erythema-weighted data calculated from spectroradiometric measurements (Brewer), even at low solar radiation angles in a solar spectrum with less UVB but significant UVA. The spore-film dosimeter values were about 103 ± 8% of the integrated dose of the Brewer instrument. The standard deviation of the spore-film measurements obtained in Japan was 12.8%. The responsivity of the spore-film system towards longer wavelengths within the UVA spectrum was tested with the Okasaki Large Spectrograph with monochromatic radiation. At a wavelength of 365 nm – in a spectral region which is dominant in many tanning lamps and with minor importance for solar radiation in summer conditions – the tested spore-film system gave results that were close (112% compared to the calibration dose) to the calibration dose which was used for irradiation. Received: 27 January 1998 / Received last revision: 21 July 1998 / Accepted: 29 July 1998  相似文献   

2.
A hallmark of oligosaccharides is their often limited spatial flexibility, allowing them to access a distinct set of conformers in solution. Viewing each individual or even the complete ensemble of conformations as potential binding partner(s) for lectins in protein–carbohydrate interactions, it is pertinent to address the question on the characteristics of bound state conformation(s) in solution. Also, it is possible that entering the lectin’s binding site distorts the low-energy topology of a glycosidic linkage. As a step to delineate the strategy of ligand selection for galactosides, a common physiological docking point, we have performed a NMR study on two non-homologous lectins showing identical monosaccharide specificity. Thus, the conformation of lactose analogues bound to bovine heart galectin-1 and to mistletoe lectin in solution has been determined by transferred nuclear Overhauser effect measurements. It is demonstrated that the lectins select the syn conformation of lactose and various structural analogues (Galβ(1→4)Xyl, Galβ(1→3)Xyl, Galβ(1→2)Xyl, and Galβ(1→3)Glc) from the ensemble of presented conformations. No evidence for conformational distortion was obtained. Docking of the analogues to the modeled binding sites furnishes explanations, in structural terms, for exclusive recognition of the syn conformer despite the non-homologous design of the binding sites.  相似文献   

3.
4.
5.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号