首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Objectives

To compare the true non-enhanced (TNE) and virtual non-enhanced (VNE) data sets in patients who underwent gastric preoperative dual-energy CT (DECT) and to evaluate potential radiation dose reduction by omitting a TNE scan.

Methods

A total of 74 patients underwent gastric DECT. The mean CT values, length, image quality and effective radiation doses for VNE and TNE images were compared.

Results

There was no statistical difference in maximal thickness of gastric tumors and maximal diameter of enlarged lymph nodes among the TNE and VNE images (P>0.05). The mean CT value differences between TNE and VNE were statistically significant for all tissue types, except for aorta attenuation measurements (P<0.05), but the absolute differences were under 10 HU. Lower noise was found for VNE images than TNE images (P<0.01). Image quality of VNE was diagnostic but lower than that of TNE (P<0.01). The dose reduction achieved by omitting the TNE acquisition was 21.40±4.44%.

Conclusion

VNE scan may potentially replace TNE as part of a multi-phase gastric preoperative staging imaging protocol with consequent saving in radiation dose.  相似文献   

2.

Objectives

To investigate the frequency of aortic calcifications at the outer edge of the false lumen and the frequency of fully circular aortic calcifications in a consecutive series of patients with aortic dissection who underwent contrast-enhanced CT.

Methods

The study population compromised of 69 consecutive subjects aged 60 years and older with a contrast-enhanced CT scan demonstrating an aortic dissection. All CT scans were evaluated for the frequency of aortic calcifications at the outer edge of the false lumen and the frequency of fully circular aortic calcifications by two experienced observers. Between observer reliability was evaluated by using Cohen’s Kappa. Differences between groups were tested using unpaired T test and Chi-square test.

Results

Presumed media calcifications were observed in 22 (32%) patients of 60 years and older and were found more frequently in chronic aortic dissection (N = 12/23, 52%) than in acute aortic dissection (N = 10/46, 22%).

Conclusion

As the intima has been torn away by the aortic dissection it is highly likely that CT scans can visualize the calcifications in the tunica media of the aorta.  相似文献   

3.

Objective

We evaluated the postmortem changes of striated muscle by comparing computed tomography (CT) images obtained postmortem and antemortem in the same patients.

Materials and Methods

We studied 33 consecutive patients who underwent antemortem CT, postmortem CT, and pathological autopsy in our tertiary care hospital between April 2009 and December 2010. Postmortem CT was performed within 20 h after death and was followed by pathological autopsy. Pathological autopsy confirmed the absence of muscular diseases such as amyotrophic lateral sclerosis, muscular dystrophy, myositis, and myasthenia, in all of the patients. The CT attenuation values of four cardiac muscle sites (anterior wall of the left ventricle, left ventricular free wall, posterior wall of the left ventricle, and the ventricular septum) and two skeletal muscle sites (the pectoralis major muscle and the erector spinae muscle) were compared between antemortem and postmortem CT using paired t test.

Results

Striated muscle had significantly greater attenuation on postmortem CT than on antemortem CT (P<0.001) in all six tissue sites. No significant association was found between postmortem change in the CT attenuation of striated muscle and gender, age, or elapsed time since death.

Conclusion

This is the first longitudinal study to show hyperattenuation of striated muscle on postmortem CT images compared with antemortem CT images in the same patients.  相似文献   

4.

Background

Artifacts caused by dental restorations, such as dental crowns, dental fillings and orthodontic appliances, are a common problem in MRI and CT scans of the head and neck. The aim of this in-vitro study was to identify and evaluate the artifacts produced by different dental restoration materials in CT and MRI images.

Methods

Test samples of 44 materials (Metal and Non-Metal) commonly used in dental restorations were fabricated and embedded with reference specimens in gelatin moulds. MRI imaging of 1.5T and CT scan were performed on the samples and evaluated in two dimensions. Artifact size and distortions were measured using a digital image analysis software.

Results

In MRI, 13 out of 44 materials produced artifacts, while in CT 41 out of 44 materials showed artifacts. Artifacts produced in both MRI and CT images were categorized according to the size of the artifact.

Significance

Metal based restoration materials had strong influence on CT and less artifacts in MRI images. Rare earth elements such as Ytterbium trifluoride found in composites caused artifacts in both MRI and CT. Recognizing these findings would help dental materials manufacturers and developers to produce materials which can cause less artifacts in MRI and CT images.  相似文献   

5.

Background

Gas trapping quantified on chest CT scans has been proposed as a surrogate for small airway disease in COPD. We sought to determine if measurements using paired inspiratory and expiratory CT scans may be better able to separate gas trapping due to emphysema from gas trapping due to small airway disease.

Methods

Smokers with and without COPD from the COPDGene Study underwent inspiratory and expiratory chest CT scans. Emphysema was quantified by the percent of lung with attenuation < −950HU on inspiratory CT. Four gas trapping measures were defined: (1) Exp−856, the percent of lung < −856HU on expiratory imaging; (2) E/I MLA, the ratio of expiratory to inspiratory mean lung attenuation; (3) RVC856-950, the difference between expiratory and inspiratory lung volumes with attenuation between −856 and −950 HU; and (4) Residuals from the regression of Exp−856 on percent emphysema.

Results

In 8517 subjects with complete data, Exp−856 was highly correlated with emphysema. The measures based on paired inspiratory and expiratory CT scans were less strongly correlated with emphysema. Exp−856, E/I MLA and RVC856-950 were predictive of spirometry, exercise capacity and quality of life in all subjects and in subjects without emphysema. In subjects with severe emphysema, E/I MLA and RVC856-950 showed the highest correlations with clinical variables.

Conclusions

Quantitative measures based on paired inspiratory and expiratory chest CT scans can be used as markers of small airway disease in smokers with and without COPD, but this will require that future studies acquire both inspiratory and expiratory CT scans.  相似文献   

6.
7.

Background and Purpose

Good reliability of methods to assess the extent of ischemia in acute stroke is important for implementation in clinical practice, especially between observers with varying experience. Our aim was to determine inter- and intra-observer reliability of the 1/3 middle cerebral artery (MCA) rule and the Alberta Stroke Program Early CT Score (ASPECTS) for different CT modalities in patients suspected of acute ischemic stroke.

Methods

We prospectively included 105 patients with acute neurological deficit due to suspected acute ischemic stroke within 9 hours after symptom onset. All patients underwent non-contrast CT, CT perfusion and CT angiography on admission. All images were evaluated twice for presence of ischemia, ischemia with >1/3 MCA involvement, and ASPECTS. Four observers evaluated twenty scans twice for intra-observer agreement. We used kappa statistics and intraclass correlation coefficient to calculate agreement.

Results

Inter-observer agreement for the 1/3 MCA rule and ASPECTS was fair to good for non-contrast CT, poor to good for CT angiography source images, but excellent for all CT perfusion maps (cerebral blood volume, mean transit time, and predicted penumbra and infarct maps). Intra-observer agreement for the 1/3 MCA rule and ASPECTS was poor to good for non-contrast CT, fair to moderate for CT angiography source images, and good to excellent for all CT perfusion maps.

Conclusion

Between observers with a different level of experience, agreement on the radiological diagnosis of cerebral ischemia is much better for CT perfusion than for non-contrast CT and CT angiography source images, and therefore CT perfusion is a very reliable addition to standard stroke imaging.  相似文献   

8.

Objectives

Cancer and metabolic bone diseases can alter the SUV. SUV values have never been measured from healthy skeletons in NaF18-PET/CT bone scans. The primary aim of this study was to measure the SUV values from normal skeletons in NaF18-PET/CT bone scans.

Methods

A retrospective study was carried out involving NaF18- PET/CT bone scans that were done at our institution between January 2010 to May 2012. Our excluding criteria was patients with abnormal real function and patients with past history of cancer and metabolic bone diseases including but not limited to osteoporosis, osteopenia and Paget’s disease. Eleven studies met all the criteria.

Results

The average normal SUVmax values from 11 patients were: cervical vertebrae 6.84 (range 4.38–8.64), thoracic vertebrae 7.36 (range 6.99–7.66), lumbar vertebrae 7.27 (range 7.04–7.72), femoral head 2.22 (range 1.1–4.3), humeral head 1.82 (range 1.2–2.9), mid sternum 5.51 (range 2.6–8.1), parietal bone 1.71 (range 1.3–2.4).

Conclusion

According to our study, various skeletal sites have different normal SUV values. SUV values can be different between the normal bones and bones with tumor or metabolic bone disease. SUV can be used to quantify NaF-18 PET/CT studies. If the SUV values of the normal skeleton are known, they can be used in the characterization of bone lesions and in the assessment of treatment response to bone diseases.  相似文献   

9.

Background

The coexistence of COPD and asthma is widely recognized but has not been well described. This study characterizes clinical features, spirometry, and chest CT scans of smoking subjects with both COPD and asthma.

Methods

We performed a cross-sectional study comparing subjects with COPD and asthma to subjects with COPD alone in the COPDGene Study.

Results

119 (13%) of 915 subjects with COPD reported a history of physician-diagnosed asthma. These subjects were younger (61.3 vs 64.7 years old, p = 0.0001) with lower lifetime smoking intensity (43.7 vs 55.1 pack years, p = 0.0001). More African-Americans reported a history of asthma (33.6% vs 15.6%, p < 0.0001). Subjects with COPD and asthma demonstrated worse disease-related quality of life, were more likely to have had a severe COPD exacerbation in the past year, and were more likely to experience frequent exacerbations (OR 3.55 [2.19, 5.75], p < 0.0001). Subjects with COPD and asthma demonstrated greater gas-trapping on chest CT. There were no differences in spirometry or CT measurements of emphysema or airway wall thickness.

Conclusion

Subjects with COPD and asthma represent a relevant clinical population, with worse health-related quality of life. They experience more frequent and severe respiratory exacerbations despite younger age and reduced lifetime smoking history.

Trial registration

ClinicalTrials.gov: NCT00608764  相似文献   

10.

Background

Angiomatous nasal polyps (ANPs), also known as angiectatic polyps, have rarely been reported in the literature. ANPs are characterized by extensive vascular proliferation and ectasia. ANPs can grow rapidly and exhibit aggressive clinical behavior that could simulate malignancy preoperatively, and they are easily confused with other diseases. In the present study, we analyzed the correlation between the computed tomography (CT) findings of nasal angiomatous polyps and their pathological features.

Methods

We evaluated CT findings and pathological features of 31 surgically proven ANPs.

Results

The study population included 16 males and 15 females aged between 27 and 81 years (mean age, 53.5 years). On CT, the masses were heterogeneous; they had a soft tissue density and filled the maxillary and/or nasal cavities. Calcifications were found in 2 of the 31 cases. The lesions showed a clear boundary (15/31). The low-density shading on CT was related to the inflammatory, necrotic, and cystic changes, and the high-density shading on CT was related to hemorrhagic areas of the mass. On contrast-enhanced CT, the center of the lesions was non-enhanced with peripheral intensification due to occlusion or compression of feeder vessels of the polyp center, and the inflammatory cells and neovascularization around the edge of the mass. The most common site of maxillary wall erosion was the medial wall (21/31), followed by the posterior lateral wall (3/31), upper wall (2/31), and septum (3/31). Of these, the nasal cavity and/or maxillary sinus were enlarged in 28 cases. These findings were associated with the chronic progress of nasal angiomatous changes.

Conclusions

CT of ANPs may demonstrate benign bone changes associated with the lesions and may also reflect the fact that ANPs do not invade peripheral soft tissue. CT demonstrated these lesions consistently and provided information useful for surgical planning.  相似文献   

11.

Background

Beyond lung cancer, screening CT contains additional information on other smoking related diseases (e.g. chronic obstructive pulmonary disease, COPD). Since pulmonary function testing is not regularly incorporated in lung cancer screening, imaging biomarkers for COPD are likely to provide important surrogate measures for disease evaluation. Therefore, this study aims to determine the independent diagnostic value of CT emphysema, CT air trapping and CT bronchial wall thickness for COPD in low-dose screening CT scans.

Methods

Prebronchodilator spirometry and volumetric inspiratory and expiratory chest CT were obtained on the same day in 1140 male lung cancer screening participants. Emphysema, air trapping and bronchial wall thickness were automatically quantified in the CT scans. Logistic regression analysis was performed to derivate a model to diagnose COPD. The model was internally validated using bootstrapping techniques.

Results

Each of the three CT biomarkers independently contributed diagnostic value for COPD, additional to age, body mass index, smoking history and smoking status. The diagnostic model that included all three CT biomarkers had a sensitivity and specificity of 73.2% and 88.%, respectively. The positive and negative predictive value were 80.2% and 84.2%, respectively. Of all participants, 82.8% was assigned the correct status. The C-statistic was 0.87, and the Net Reclassification Index compared to a model without any CT biomarkers was 44.4%. However, the added value of the expiratory CT data was limited, with an increase in Net Reclassification Index of 4.5% compared to a model with only inspiratory CT data.

Conclusion

Quantitatively assessed CT emphysema, air trapping and bronchial wall thickness each contain independent diagnostic information for COPD, and these imaging biomarkers might prove useful in the absence of lung function testing and may influence lung cancer screening strategy. Inspiratory CT biomarkers alone may be sufficient to identify patients with COPD in lung cancer screening setting.  相似文献   

12.

Aims

Accurate computed tomography (CT)-based reconstruction of coronary morphometry (diameters, length, bifurcation angles) is important for construction of patient-specific models to aid diagnosis and therapy. The objective of this study is to validate the accuracy of patient coronary artery lumen area obtained from CT images based on intravascular ultrasound (IVUS).

Methods and Results

Morphometric data of 5 patient CT scans with 11 arteries from IVUS were reconstructed including the lumen cross sectional area (CSA), diameter and length. The volumetric data from CT images were analyzed at sub-pixel accuracy to obtain accurate vessel center lines and CSA. A new center line extraction approach was used where an initial estimated skeleton in discrete value was obtained using a traditional thinning algorithm. The CSA was determined directly without any circular shape assumptions to provide accurate reconstruction of stenosis. The root-mean-square error (RMSE) for CSA and diameter were 16.2% and 9.5% respectively.

Conclusions

The image segmentation and CSA extraction algorithm for reconstruction of coronary arteries proved to be accurate for determination of vessel lumen area. This approach provides fundamental morphometric data for patient-specific models to diagnose and treat coronary artery disease.  相似文献   

13.

Aim

The aim of our study was to compare the staging of the disease declared before anticancer treatment was begun with the staging that was found after the planning PET/CT scanning with 18F-FLT was performed.

Background

PET/CT in radiotherapy planning of head and neck cancers can facilitate the contouring of the primary tumour and the definition of metastatic lymph nodes.

Materials and methods

Between November 2010 and November 2013, 26 patients suffering from head and neck carcinomas underwent planning PET/CT examination with 18F-FLT. We compared the staging of the disease and the treatment strategy declared before and after 18F-FLT-PET/CT was performed.

Results

The findings from 18FLT-PET/CT led in 22 patients to a change of staging: in 19 patients it led to upstaging of the disease and in 3 patients it led to downstaging of the disease. In one patient, a secondary malignancy was found.

Conclusions

We have confirmed in this study that the use of 18F-FLT-PET/CT scanning in radiotherapy planning of squamous cell head and neck carcinomas has a great potential in the precise evaluation of disease staging and consequently in the precise determination of target volumes.  相似文献   

14.

Background

Posttreatment surveillance for the local and regional recurrence of the head and neck squamous cell carcinoma often requires a multimodality techniques that include PET combined with CT, MRI, US.

Aim

The purpose of this study is to compare the diagnostic performance of two imaging techniques (PET/CT and US), and their combined use for the detection of a subclinical regional recurrence in patients after HNSCC treatment.

Materials and methods

83 patients after completion of the HNSCC treatment underwent both US and PET/CT on the mean follow-up of 14 months after initial treatment.

Results

The sensitivity and specificity of PET/CT were 86% and 82%, respectively; US values reached 81% and 87%, respectively. PPV was 79% for PET/CT, and 83% for US. NPV was 89% for PET/CT, and 85% for US. The overall accuracy for PET/CT and US was 84% for both methods.

Conclusion

US could be regarded as complementary to PET/CT as the procedures with highest sensitivity, specificity and NPV for detecting subclinical regional recurrences after HNSCC treatment.  相似文献   

15.

Background

Development of adult respiratory disease is influenced by events in childhood. The impact of childhood pneumonia on chronic obstructive pulmonary disease (COPD) is not well defined. We hypothesize that childhood pneumonia is a risk factor for reduced lung function and COPD in adult smokers.

Methods

COPD cases and control smokers between 45–80 years old from the United States COPDGene Study were included. Childhood pneumonia was defined by self-report of pneumonia at <16 years. Subjects with lung disease other than COPD or asthma were excluded. Smokers with and without childhood pneumonia were compared on measures of respiratory disease, lung function, and quantitative analysis of chest CT scans.

Results

Of 10,192 adult smokers, 854 (8.4 %) reported pneumonia in childhood. Childhood pneumonia was associated with COPD (OR 1.40; 95 % CI 1.17-1.66), chronic bronchitis, increased COPD exacerbations, and lower lung function: post-bronchodilator FEV1 (69.1 vs. 77.1 % predicted), FVC (82.7 vs. 87.4 % predicted), FEV1/FVC ratio (0.63 vs. 0.67; p < 0.001 for all comparisons). Childhood pneumonia was associated with increased airway wall thickness on CT, without significant difference in emphysema. Having both pneumonia and asthma in childhood further increased the risk of developing COPD (OR 1.85; 95 % CI 1.10-3.18).

Conclusions

Children with pneumonia are at increased risk for future smoking-related lung disease including COPD and decreased lung function. This association is supported by airway changes on chest CT scans. Childhood pneumonia may be an important factor in the early origins of COPD, and the combination of pneumonia and asthma in childhood may pose the greatest risk.

Clinical trials registration

ClinicalTrials.gov, NCT00608764 (Active since January 28, 2008).

Electronic supplementary material

The online version of this article (doi:10.1186/s12931-015-0273-8) contains supplementary material, which is available to authorized users.  相似文献   

16.

Background and Aims

Transcatheter intraarterial techniques can effectively deliver chemotherapeutic agents to tumor and improve the efficacy of chemotherapy. The present study is designed to evaluate the effect of transcatheter intraarterial techniques on the distribution of doxorubicin in relation to blood vessels in liver cancer.

Methods

VX2 tumors were implanted in the livers of 32 rabbits. The animals were divided into 4 groups of 8 animals each. Group 1 (doxo iv) animals received doxorubicin intravenous injection; group 2 (doxo ia) received doxorubicin hepatic intraarterial infusion; group 3 (doxo ia + E) received doxorubicin hepatic intraarterial infusion followed by embolization; group 4 (doxo + L ia + E) received hepatic intraarterial infusion of doxorubicin mixed with Lipiodol followed by embolization. Ten minutes or 4 hours after treatment, the animals were sacrificed and tumors were sampled. Immunofluorescence techniques were used to evaluate the distribution of doxorubicin in relation to blood vessels.

Results

Doxorubicin fluorescence was distributed around tumor blood vessels and decreased with distance from the blood vessels. Tumor cells in avascular and adjacent regions were not exposed to detectable concentrations of doxorubicin. Tumors in the group 2, 3 and 4 had a significant increase in doxorubicin penetration compared with the group 1 tumors (P<0.05). Among the three groups of transcatheter therapies, doxorubicin penetration distance in group 3 was significantly larger than that in group 2 and 4 (P<0.05), and no significant difference was found between group 2 and 4 tumors (P>0.05) at 10 minutes. In contrast, at 4 hours and in total, both group 3 and 4 tumors had significant increases in drug penetration compared with group 2 (P<0.05), and no significant difference was noted between group 3 and 4 tumors (P>0.05).

Conclusion

Transcatheter intraarterial therapies improve doxorubicin penetration in liver cancer; nevertheless their effect on drug distribution is somewhat limited.  相似文献   

17.

Background/Objectives

Mucosal leishmaniasis (ML) is a progressive disease that affects cartilage and bone structures of the nose and other upper respiratory tract structures. Complications associated with ML have been described, but there is a lack of studies that evaluate the structural changes of the nose and paranasal sinuses in ML using radiological methods. In this study, we aimed to assess the opacification of the paranasal sinuses in patients with treated ML and any anatomical changes in the face associated with ML using multidetector computed tomography scans (MDCT) of the sinuses. We compared the findings with a control group.

Methodology/Principal Findings

We evaluated 54 patients with treated ML who underwent CT scans of the sinuses and compared them with a control group of 40 patients who underwent orbital CT scans. The degree of sinus disease was assessed according to the Lund-Mackay criteria. Forty of the 54 patients with a history of ML (74.1%) had a tomographic score compatible with chronic sinusitis (Lund-Mackay ≥4). CT scans in the leishmaniasis and control groups demonstrated significant differences in terms of facial structure alterations. Patients from the ML group showed more severe levels of partial opacification and pansinus mucosal thickening (42.6%) and a greater severity of total opacification. Patients from the ML group with a Lund-Mackay score ≥4 presented longer durations of disease before treatment and more severe presentations of the disease at diagnosis.

Conclusion/Significance

CT scans of the sinuses of patients with ML presented several structural alterations, revealing a prominent destructive feature of the disease. The higher prevalence in this study of chronic rhinosinusitis observed in CT scans of patients with treated ML than in those of the control group suggests that ML can be considered a risk factor for chronic rhinosinusitis in this population (p<0.05).  相似文献   

18.

Background

Continuity of care (COC) is a widely accepted core principle of primary care and has been associated with patient satisfaction, healthcare utilization and mortality in many, albeit small, studies.

Objective

To assess the relationship between longitudinal continuity with a primary care physician (PCP) and likelihood of death in the French general population.

Design

Observational study based on reimbursement claims from the French national health insurance (NHI) database for salaried workers (2007–2010).

Setting

Primary care.

Patients

We extracted data on the number and pattern of visits made to a PCP and excluded all patients who did not visit a PCP at least twice within 6 months. We recorded age, gender, comorbidities, social status, and deaths.

Main outcome measures

The primary endpoint was death by all causes. We measured longitudinal continuity of care (COC) with a PCP twice a year between 2007 and 2010, using the COC index developed by Bice and Boxerman. We introduced the COC index as time-dependent variables in a survival analysis after adjustment for age, gender and stratifying on comorbidities and social status.

Results

A total of 325 742 patients were included in the analysis. The average COC index ranged from 0.74 (SD: 0.35) to 0.76 (0.35) (where 1.0 is perfect continuity). Likelihood of death was lower in patients with higher continuity (hazard ratio for an increase in 0.1 of continuity, adjusted for age, sex, and stratified on comorbidities and social status: 0.96 [0.95–0.96]).

Conclusion

Higher longitudinal continuity was associated with a reduced likelihood of death.  相似文献   

19.

Introduction

There is a relative lack of information about the death rate and morbidity of non-cystic fibrosis bronchiectasis and most studies are limited due to referral bias. We wanted to assess death rate and morbidity in those patients at our hospital.

Methods

Adult patients seen at our department between June 2006 and November 2009 were recruited if the key string "bronchiect-" was mentioned in electronic clinical records and if chest CT imaging was available. Clinical records of all patients with confirmed radiologic diagnosis of bronchiectasis were reviewed and clinical characteristics were analyzed.

Results

539 patients with a radiographic diagnosis of non-cystic fibrosis bronchiectasis were identified in a retrospective cross-sectional analysis giving a prevalence of 2.6% in our hospital population. A wide range of etiologies was found with idiopathic bronchiectasis in 26%. In the 41 months interval, 57 patients (10.6%) died. We found a median exacerbation rate of 1.94 per year. Bacterial colonization status was associated with more deaths, exacerbation rate, symptoms and reduced pulmonary function. Pulmonary hypertension was found in 48% of our patients.

Conclusions

We evaluated a large non-cystic fibrosis bronchiectasis population, and provided new epidemiological data on associations between clinical characteristics and deaths and morbidity in these patients.  相似文献   

20.

Objectives

To evaluate the diagnostic accuracy and the potential radiation dose reduction of dual-energy CT (DECT) for tumor (T) staging of colorectal cancer (CRC) using iodine overlay (IO) and virtual nonenhanced (VNE) images.

Materials and Methods

This retrospective study included 103 consecutive patients who underwent nonenhanced CT and enhanced DECT for preoperative CRC staging. Enhanced weighted-average (WA), IO and VNE images were reconstructed from enhanced 80 kVp and Sn140 kVp scans. Two radiologists assessed image qualities of the true nonenhanced (TNE) and VNE images. For T-staging, another two radiologists independently interpreted all scans in two separate reading sessions: in the first session, only images derived from the single phase DECT acquisition (IO and VNE images) were read. In the second reading session after 30 to 50 (average:42) days, the same assessment was again performed with the TNE and enhanced WA images thereby simulating conventional dual-phase single-energy CT. The tumor node metastasis (TNM) system was used for staging with histopathologic reports as gold standard. Analysis of variance was used for statistical analysis.

Results

The signal-to-noise ratios (SNRs) of the tumors and normal reference tissues showed significant correlation between the TNE and VNE images (P<0.01). The mean iodine overlay value (48.4 HU±12.2) and enhancement (49.4 HU±11.8) value of CRCs had no significant difference (P = 0.52).The mean image noise on TNE (5.0±1.1) and VNE (5.3±1.1) images were similar (P = 0.07). The quantitative qualities of the VNE images were mildly inferior to the TNE images. Overall accuracy of T-stage CRC when using single-phase acquisition was slightly better than the dual-phase acquisition (90.3% vs 87.4%) (P = 0.51). The mean dose of the single-phase DECT acquisition was 6.2mSv comparing with 14.3mSv of dual-phase.

Conclusion

Single-phase DECT using IO and VNE images yields a high accuracy in T-staging of CRCs. Thereby, the radiation exposure of the patients can be reduced.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号