首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
When large defects occur, bone regeneration can be supported by bone grafting and biophysical stimuli like electric and magnetic stimulation (EMS). Clinically established EMS modes are external coils and surgical implants like an electroinductive screw system, which combines a magnetic and electric field, e.g., for the treatment of avascular bone necrosis or pseudarthrosis. For optimization of this implant system, an in vitro test setup was designed to investigate effects of EMS on human osteoblasts on different 3D scaffolds (based on calcium phosphate and collagen). Prior to the cell experiments, numerical simulations of the setup, as well as experimental validation, via measurements of the electric parameters induced by EMS were conducted. Human osteoblasts (3 × 105 cells) were seeded onto the scaffolds and cultivated. After 24 h, screw implants (Stryker ASNIS III s-series) were centered in the scaffolds, and EMS was applied (3 × 45 min per day at 20 Hz) for 3 days. Cell viability and collagen type 1 (Col1) synthesis were determined subsequently. Numerical simulation and validation showed an adequate distribution of the electric field within the scaffolds. Experimental measurements of the electric potential revealed only minimal deviation from the simulation. Cell response to stimulation varied with scaffold material and mode of stimulation. EMS-stimulated cells exhibited a significant decrease of metabolic activity in particular on collagen scaffolds. In contrast, the Col1/metabolic activity ratio was significantly increased on collagen and non-sintered calcium phosphate scaffolds after 3 days. Exclusive magnetic stimulation showed similar but nonsignificant tendencies in metabolic activity and Col1 synthesis. The cell tests demonstrate that the new test setup is a valuable tool for in vitro testing and parameter optimization of the clinically used electroinductive screw system. It combines magnetic and electric stimulation, allowing in vitro investigations of its influence on human osteoblasts.  相似文献   

2.
Although normal human keratinocytes are known to migrate toward the cathode in a direct current (DC) electric field, other effects of the electric stimulation on keratinocyte activities are still unclear. We have investigated the keratinocyte differentiation under monodirectional pulsed electric stimulation which reduces the electrothermal and electrochemical hazards of a DC application. When cultured keratinocytes were exposed to the electric field of 3 V (ca. 100 mV/mm) or 5 V (ca. 166 mV/mm) at a frequency of 4,800 Hz for 5 min a day for 5 days, cell growth under the 5-V stimulation was significantly suppressed as compared with the control culture. Expression of mRNAs encoding keratinocyte differentiation markers such as keratin 10, involucrin, transglutaminase 1, and filaggrin was significantly increased in response to the 5-V stimulation, while the 3-V stimulation induced no significant change. After the 5-V stimulation, enhanced immunofluorescent stainings of involucrin and filaggrin were observed. These results indicate that monodirectional pulsed electric stimulation induces the keratinocyte differentiation with growth arrest.  相似文献   

3.
A valid sham control is important for determining the efficacy and effectiveness of repetitive transcranial magnetic stimulation (rTMS) as an experimental and clinical tool. Given the manner in which rTMS is applied, separately or in combination with self-regulatory approaches, and its intended impact on brain states, a valid sham control of this type may well serve as a meaningful control for biofeedback studies, where efforts to develop a credible control have often been less than ideal. This study examined the effectiveness of focal electrical stimulation of the frontalis muscle as a sham technique for blinding participants to high-frequency rTMS over the dorso-lateral prefrontal cortex (DLPFC) at durations, intensities, and schedules of stimulation similar to many clinical applications. In this within-subjects single blind design, 19 participants made guesses immediately after receiving 54 counterbalanced rTMS sessions (sham, 10 Hz, 20 Hz); 7 (13 %) of the guesses were made for sham, 31 (57 %) were made for 10 Hz, and 16 (30 %) were made for 20 Hz. Participants correctly guessed the sham condition 6 % (CI 1, 32 %) of the time, which is less than the odds of chance (i.e., of guessing at random, 33 %); correctly guessed the 10 Hz condition 66 % (CI 43, 84 %) of the time, which was greater than chance; and correctly guessed the 20 Hz condition 41 % (CI 21, 65 %) of the time, which was no different than chance. Focal electrical stimulation therefore can be an effective sham control for high-frequency rTMS of the DLPFC, as well as for active biofeedback interventions. Participants were unaware that electrical stimulation was, in fact, sham rTMS.  相似文献   

4.
Patient-specific analyses of the mechanical properties of bones become increasingly important for the management of patients with osteoporosis. The potential of composite finite elements (CFEs), a novel FE technique, to assess the apparent stiffness of vertebral trabecular bone is investigated in this study. Segmented volumes of cylindrical specimens of trabecular bone are compared to measured volumes. Elasticity under uniaxial loading conditions is simulated; apparent stiffnesses are compared to experimentally determined values. Computational efficiency is assessed and recommendations for simulation parameters are given. Validating apparent uniaxial stiffnesses results in concordance correlation coefficients 0.69 ≤ r𝒸 ≤ 0.92 for resolutions finer than 168 μm, and an average error of 5.8% between experimental and numerical results at 24 μm resolution. As an application, the code was used to compute local, macroscopic stiffness tensors for the trabecular structure of a lumbar vertebra. The presented technique allows for computing stiffness using smooth FE meshes at resolutions that are well achievable in peripheral high resolution quantitative CT. Therefore, CFEs could be a valuable tool for the patient-specific assessment of bone stiffness.  相似文献   

5.
For developing a clinically effective bone regeneration strategy, we compare the bone regeneration potential of cultured allogeneic bone marrow-derived mesenchymal stem cells (BM-MSCs) and of autologous BM-MSCs loaded onto allogeneic cancellous bone granule scaffolds. A critical-sized segmental bone defect was made at the mid-shaft of both radiuses in 19 New Zealand White rabbits (NWRs). In the experimental group, allogeneic BM-MSCs loaded onto small-sized allogeneic cancellous bone granules (300~700 um in diameter) were implanted in one side of a bone defect. In the control group, autologous BM-MSCs loaded onto allogeneic cancellous granules were grafted in the other side. Bone regeneration was assessed by radiographic evaluation at 4, 8, 12 and 16 weeks post-implantation and by micro-computed tomography (micro-CT) and histological evaluation at 8 and 16 weeks. The experimental groups showed lower bone quantity indices (BQIs) than the control groups at 12 and 16 weeks (p?<?0.05), although no significant difference was observed at 4 and 8 weeks (p?>?0.05). Micro-CT analysis revealed that both groups had similar mean total bone volume and other parameters including trabecular thickness, number and separation at either 8 or 16 weeks. Only bone surface area revealed less area in the experimental group at 16 weeks. Histological evaluation of 8-week and 16-week specimens showed similar biologic processes of new bone formation and maturation. There was no inflammatory reaction indicating an adverse immune response in both allogeneic and autologous MSC groups. In conclusion, allogeneic BM-MSCs loaded onto allogeneic cancellous bone granules had comparable bone regeneration potential to autologous BM-MSCs in a rabbit radial defect model.  相似文献   

6.
Mechanical stimulation, in the form of fluid perfusion or mechanical strain, enhances osteogenic differentiation and overall bone tissue formation by mesenchymal stems cells cultured in biomaterial scaffolds for tissue engineering applications. In silico techniques can be used to predict the mechanical environment within biomaterial scaffolds, and also the relationship between bone tissue regeneration and mechanical stimulation, and thereby inform conditions for bone tissue engineering experiments. In this study, we investigated bone tissue regeneration in an idealised hydrogel scaffold using a mechano-regulation model capable of predicting tissue differentiation, and specifically compared five loading cases, based on known experimental bioreactor regimes. These models predicted that low levels of mechanical loading, i.e. compression (0.5% strain), pore pressure of 10 kPa and a combination of compression (0.5%) and pore pressure (10 kPa), could induce more osteogenic differentiation and lead to the formation of a higher bone tissue fraction. In contrast greater volumes of cartilage and fibrous tissue fractions were predicted under higher levels of mechanical loading (i.e. compression strain of 5.0% and pore pressure of 100 kPa). The findings in this study may provide important information regarding the appropriate mechanical stimulation for in vitro bone tissue engineering experiments.  相似文献   

7.
Theta (4–12 Hz) and gamma (30–80 Hz) rhythms are considered important for cortical and hippocampal function. Although several neuron types are implicated in rhythmogenesis, the exact cellular mechanisms remain unknown. Subthreshold electric fields provide a flexible, area-specific tool to modulate neural activity and directly test functional hypotheses. Here we present experimental and computational evidence of the interplay among hippocampal synaptic circuitry, neuronal morphology, external electric fields, and network activity. Electrophysiological data are used to constrain and validate an anatomically and biophysically realistic model of area CA1 containing pyramidal cells and two interneuron types: dendritic- and perisomatic-targeting. We report two lines of results: addressing the network structure capable of generating theta-modulated gamma rhythms, and demonstrating electric field effects on those rhythms. First, theta-modulated gamma rhythms require specific inhibitory connectivity. In one configuration, GABAergic axo-dendritic feedback on pyramidal cells is only effective in proximal but not distal layers. An alternative configuration requires two distinct perisomatic interneuron classes, one exclusively receiving excitatory contacts, the other additionally targeted by inhibition. These observations suggest novel roles for particular classes of oriens and basket cells. The second major finding is that subthreshold electric fields robustly alter the balance between different rhythms. Independent of network configuration, positive electric fields decrease, while negative fields increase the theta/gamma ratio. Moreover, electric fields differentially affect average theta frequency depending on specific synaptic connectivity. These results support the testable prediction that subthreshold electric fields can alter hippocampal rhythms, suggesting new approaches to explore their cognitive functions and underlying circuitry.  相似文献   

8.
During standard electrochemotherapy (ECT), using a train of 1,000 V/cm amplitude rectangular pulses with 1 Hz frequency, patients experience an unpleasant sensation and slight edema. According to the patients, muscle contractions provoked by high amplitude (about 1,000 V/cm) and low repetition frequency (1 Hz) pulses are the most unpleasant and painful sensations. Recently, ECT using low voltage and higher repetition frequency (LVHF) has been shown to be an effective tool for inhibiting tumor growth. The aim of the present study was to optimize electric pulse amplitude and repetition frequency for LVHF ECT by sampling the different sets of pulse parameters on cell viability and permeabilization. In ECT, a reversible effect based on high permeabilization is desirable. For this purpose, we used bleomycin to evaluate the permeabilization of K562 and MIA-PACA2 cells caused by low voltage (50–150 V/cm) and higher repetition frequency (4–6 kHz) electric pulses. We show that the reversible effect with electropermeabilization of the cells caused by LVHF ECT is accessible; this interaction is more effective for electric pulses with 70 V/cm amplitude.  相似文献   

9.
The aim of this study was to investigate the effect of three different scaffolds on the viability and differentiation of adipose-derived mesenchymal stem cells (ADMSCs) to osteoblast for bone regeneration of calvarial defect in rabbit model. Adipose was harvested from the nape of 12 rabbits by direct surgery or hollow-tip cannula. Two standardized circular calvarial defects (case and control), 8 mm in diameter each, were created in all the animals. The animals were divided into 3 different groups. In group 1 (G1), the defect was filled with polyamide + ADMSC. In group 2, poly lactic-co-glycolic acid + ADMSC was used. In group 3, decellularized amniotic membrane + ADMSC was applied. In the control defect, the non-seeded scaffolds were applied for filling the defect. Decellularized pericardial scaffolds were used as a membrane on the scaffolds. The animals were euthanized 2, 4, and 8 weeks of operation and new bone formation was assessed by different analyses. Immunohistochemical (IHC) staining with osteopontin and osteocalcin antibodies was also performed. After 2 weeks of wound healing, minimal bone regeneration was detected in all groups. Almost complete defect closure was observed in all experimental groups after 8 weeks of operation, with the greatest defect closure in the animals treated with polyamide scaffolds as compared to biopsies obtained from control defects and other experimental groups. The maximal tensile load was higher in G1, 4 and 8 weeks postoperatively, suggesting the usefulness of polyamide + ADMSC for bone regeneration in calvarial defects. Results of the IHC staining demonstrated a significant difference between seeded and non-seeded scaffold in both short- and long-term follow-ups (P < 0.05). In addition, a significant difference was observed in enhancement of IHC staining of both markers in polyamide group (seeded or non-seeded) 4 and 8 weeks postoperatively in comparison with other scaffolds. It was concluded that bone regeneration in critical calvarial defect was more successful in seeded polyamide.  相似文献   

10.
Acrylic bone cements are widely used for fixation of joint prostheses as well as for vertebral body augmentation procedures of vertebroplasty and balloon kyphoplasty, with the cement zone(s) being subjected to repeated mechanical loading in each of these applications. Although, in vertebroplasty and balloon kyphoplasty, the cement zone is exposed to mainly cyclical compressive load, the compressive fatigue properties of acrylic bone cements used in these procedures are yet to be determined. The purposes of the present study were to determine the compressive fatigue properties of a commercially available cement brand used in vertebroplasty, including the effect of frequency on these properties; to identify the cement failure modes under compressive cyclical load; and to introduce a screening method that may be used to shorten the lengthy character of the standardized fatigue tests. Osteopal \({^\circledR } \mathrm{V}\) was used as the model cement in this study. The combinations of maximum stress and frequency used were 50.0, 55.0, 60.0, 62.5 and 75.5 MPa at 2 Hz; and of 40.0, 55.0, 60.0, 62.5 or 75.5 MPa at 10 Hz. Through analysis of nominal strain-number of loading cycles results, three cement failure modes were identified. The estimated mean fatigue limit at 2 Hz (55.4 MPa) was significantly higher than that at 10 Hz (41.1 MPa). The estimated fatigue limit at 2 Hz is much higher than stresses commonly found in the spine and also higher than that for other acrylic bone cements tested in a full tension–compression fatigue test, which indicates that tension–compression fatigue testing may substantially underestimate the performance of cements intended for vertebroplasty. A screening method was introduced which may be used to shorten the time spent in performing compressive fatigue tests on specimens of acrylic bone cement for use in vertebral body augmentation procedures.  相似文献   

11.
Complex Dielectric Properties of Sulfate-Reducing Bacteria Suspensions   总被引:2,自引:0,他引:2  
Sulfate-reducing bacteria (SRB) can potentially enhance the remediation of heavy metals in the subsurface. Previous geophysical research has demonstrated the sensitivity of electrical measurements to SRB-mediated mineral transformation in porous media. However, the inherent dielectric properties of SRB and their direct contribution to the electrical properties of porous media are poorly understood. We studied the complex dielectric properties of SRB (Desulfovibrio vulgaris) suspensions at different concentrations and at different growth stages using a two-electrode dielectric spectroscopy measurement over the frequency range of 20 Hz to 1 MHz. Our results show higher dielectric responses (relative dielectric permittivity, real and imaginary conductivity) occurred with higher bacteria concentration at frequencies <10 kHz. Additionally, permittivity and conductivity both decreased as cells aged from mid-log phase to late stationary phase. Our results suggest that dielectric spectroscopy measurements can be used to noninvasively monitor biomass and various growth stages of SRB. Our work advances the interpretation of electrical signals associated with SRB observed in the subsurface.  相似文献   

12.
The production, distribution and use of electricity can generate low frequency electric and magnetic fields (50–60 Hz). Considering that some studies showed adverse effects on pancreatic β-cells exposed to these fields; the present study aimed to analyze the effects of 60 Hz electric fields on membrane potential during the silent and burst phases in pancreatic β-cells using a mathematical model. Sinusoidal 60 Hz electric fields with amplitude ranging from 0.5 to 4 mV were applied on pancreatic β-cells model. The sinusoidal electric field changed burst duration, inter-burst intervals (silent phase) and spike sizes. The parameters above presented dose-dependent response with the voltage amplitude applied. In conclusion, theoretical analyses showed that a 60 Hz electric field with low amplitudes changes the membrane potential in pancreatic β-cells.  相似文献   

13.
We study the efficacy of bone regeneration by using two differently sized allogeneic cancellous bone granules loaded with autologous cultured osteoblasts in a rabbit model. Critical-sized bone defects of the radial shaft were made in 40 New Zealand White rabbits. Small allogeneic bone granules (150–300 μm in diameter) loaded with cultured differentiated autologous osteoblasts were implanted into one forearm (SBG group) and large bone granules (500–710 μm) loaded with osteoblasts were implanted into the forearm of the other side (LBG group). Radiographic evaluations were performed at 3, 6, 9 and 12 weeks and histology and micro-CT image analysis were carried out at 6 and 12 weeks post-implantation. On radiographic evaluation, the LBG group showed a higher bone quantity index at 3 and 6 weeks post-implantation (P?<?0.05) but statistical significance was lost at 9 and 12 weeks. The progression of biological processes of the SBG group was faster than that of the LBG group. On micro-CT image analysis, the LBG group revealed a higher total bone volume and surface area than the SBG group at 6 weeks (P?<?0.05) but the difference decreased at 12 weeks and was without statistical significance. Histological evaluation also revealed faster progression of new bone formation and maturation in the SBG group. Thus, the two differently sized allogeneic bone granules loaded with co-cultured autologous osteoblasts show no differences in the amount of bone regeneration, although the SBG group exhibits faster progression of bone regeneration and remodeling. This method might therefore provide benefits, such as a short healing time and easy application in an injectable form, in a clinical setting.  相似文献   

14.
Electric field distribution in biological systems was investigated. In the analysis both the conductive and the dielectric properties of biological systems were considered. Making use of the complex dielectric coefficient, equations which describe the electric field behavior in such media, were formulated. These equations were solved numerically for a few biological systems. The solutions show that the macroscopic field distribution, for example, the refraction of the ECG wave upon passing from one tissue into another, is mainly determined by the tissue's conductive properties (in the frequency range of 0–108 Hz). However, the microscopic field distribution around the individual cells is determined by the conductive, the dielectric or both properties, depending on the frequency. At frequencies below 104 Hz the field configuration is determined largely by the system's conductive properties. At frequencies above 107 – 108 Hz, by the dielectric properties and in the range of 104 – 106 Hz both properties affect the field distribution. In this range the field direction may be shifted by as much as 90° by relatively small frequency changes.  相似文献   

15.
Tooth loss often results in alveolar bone resorption because of lack of mechanical stimulation. Thus, the mechanism of mechanical loading on stem cell osteogenesis is crucial for alveolar bone regeneration. We have investigated the effect of mechanical loading on osteogenesis in human dental pulp stromal cells (hDPSCs) in a novel in vitro model. Briefly, 1?×?107 hDPSCs were seeded into 1 ml 3 % agarose gel in a 48-well-plate. A loading tube was then placed in the middle of the gel to mimic tooth-chewing movement (1 Hz, 3?×?30 min per day, n?=?3). A non-loading group was used as a control. At various time points, the distribution of live/dead cells within the gel was confirmed by fluorescence markers and confocal microscopy. The correlation and interaction between the factors (e.g. force, time, depth and distance) were statistically analysed. The samples were processed for histology and immunohistochemistry. After 1–3 weeks of culture in the in-house-designed in vitro bioreactor, fluorescence imaging confirmed that additional mechanical loading increased the viable cell numbers over time as compared with the control. Cells of various phenotypes formed different patterns away from the reaction tube. The cells in the middle part of the gel showed enhanced alkaline phosphatase staining at week 1 but reduced staining at weeks 2 and 3. Additional loading enhanced Sirius Red and type I collagen staining compared with the control. We have thus successfully developed a novel in-house-designed in vitro bioreactor mimicking the biting force to enhance hDPSC osteogenesis in an agarose scaffold and to promote bone formation and/or prevent bone resorption.  相似文献   

16.
An electro-absorption modulator based on indium tin oxide is proposed by constructing a waveguide consisting of metal-dielectric-ITO-dielectric-Si stack. Applying a negative voltage bias on the ITO layer, carrier accumulation occurs at both dielectric-ITO interfaces, which dramatically changes the guided mode properties due to the epsilon-near-zero effect. By tuning the real part of the permittivity around zero, the guided plasmonic mode concentrates in either ITO or dielectric layers, resulting in a high propagation loss. These dual carrier accumulation layers significantly improve the extinction ratio of the modulator. A further improvement is obtained by using high refractive index dielectric thin layers, which provides a strong optical confinement in the carrier accumulation layers. The dual carrier accumulation layer device shows a 200 % increase of the modulation efficiency compared to a single accumulation layer design. A modulation depth of 9.9 dB/μm can be achieved by numerical simulation.  相似文献   

17.
The starch-rich duckweed Landoltia punctata is a valuable aquatic plant in wastewater purification, bioenergy production, and many other applications. A highly efficient callus induction and plant regeneration protocol is desirable so that biotechnology can be used to develop new varieties with added value and adaptation. We studied both known and unknown factors that influence callus induction in L. punctata and obtained almost 100 % induction rate in 30 days. The optimum medium for callus induction was MS basal medium supplemented with 1 % sorbitol, 15 mg/L 2,4-D, and 2 mg/L 6-BA. Green fragile callus was induced from the meristematic region in the budding pouches. The optimum photoperiod for callus induction was 16-h day, and the optimum explant orientation was dorsal side down on the medium. The optimum medium for callus subculture was WPM basal medium supplemented with 2 % sorbitol, 4 mg/L 2,4-D, and 0.5 mg/L TDZ. Green callus could be maintained by subculture once every 4 weeks. However, when the subculture cycle was prolonged to 6 weeks or longer, yellow fragile embryogenic callus was obtained. The optimum plant regeneration medium was MS medium supplemented with 0.5 % sucrose, 1 % sorbitol, and 1.0 mg/L 6-BA with frond regeneration rates of approximately 90 %. The regenerated fronds rooted in Hoagland’s liquid medium in 1 week. The callus induction and frond regeneration protocol was tested for its efficiency in geographically distinct strains 5502, 8721, and 9264. Thus, we obtained a rapid and efficient protocol for callus induction and frond regeneration of L. punctata, which takes only 9 weeks.  相似文献   

18.
Electrical stimulation of sub-cortical brain regions (the basal ganglia), known as deep brain stimulation (DBS), is an effective treatment for Parkinson’s disease (PD). Chronic high frequency (HF) DBS in the subthalamic nucleus (STN) or globus pallidus interna (GPi) reduces motor symptoms including bradykinesia and tremor in patients with PD, but the therapeutic mechanisms of DBS are not fully understood. We developed a biophysical network model comprising of the closed loop cortical-basal ganglia-thalamus circuit representing the healthy and parkinsonian rat brain. The network properties of the model were validated by comparing responses evoked in basal ganglia (BG) nuclei by cortical (CTX) stimulation to published experimental results. A key emergent property of the model was generation of low-frequency network oscillations. Consistent with their putative pathological role, low-frequency oscillations in model BG neurons were exaggerated in the parkinsonian state compared to the healthy condition. We used the model to quantify the effectiveness of STN DBS at different frequencies in suppressing low-frequency oscillatory activity in GPi. Frequencies less than 40 Hz were ineffective, low-frequency oscillatory power decreased gradually for frequencies between 50 Hz and 130 Hz, and saturated at frequencies higher than 150 Hz. HF STN DBS suppressed pathological oscillations in GPe/GPi both by exciting and inhibiting the firing in GPe/GPi neurons, and the number of GPe/GPi neurons influenced was greater for HF stimulation than low-frequency stimulation. Similar to the frequency dependent suppression of pathological oscillations, STN DBS also normalized the abnormal GPi spiking activity evoked by CTX stimulation in a frequency dependent fashion with HF being the most effective. Therefore, therapeutic HF STN DBS effectively suppresses pathological activity by influencing the activity of a greater proportion of neurons in the output nucleus of the BG.  相似文献   

19.
Intramedullary pressure (ImP) and low-level bone strain induced by oscillatory muscle stimulation (MS) has the potential to mitigate bone loss induced by disuse osteopenia, i.e., hindlimb suspension (HLS). To test this hypothesis, we evaluated (a) MS-induced ImP and bone strain as function of stimulation frequency and (b) the adaptive responses to functional disuse, and disuse plus 1 and 20 Hz stimulation in vivo. Femoral ImP and bone strain generated by MS were measured in the frequencies of 1–100 Hz in four rats. Forty retired breeder rats were used for the in vivo HLS study. The quadriceps muscle was stimulated at frequencies of 1 and 20 Hz, 10 min/d for four weeks. The metaphyseal trabecular bone quantity and microstructure at the distal femur were evaluated using μCT, while bone formation indices were analyzed using histomorphometric technique. Oscillatory MS generated a maximum ImP of 45±9 mmHg at 20 Hz and produced a maximum matrix strain of 128±19 με at 10 Hz. Our analyses from the in vivo study showed that MS at 20 Hz was able to attenuate trabecular bone loss and partially maintain the microstructure induced by HLS. Conversely, there was no evidence of an adaptive effect of stimulation at 1 Hz on disused skeleton. The results suggested that oscillatory MS regulates fluid dynamics and mechanical strain in bone, which serves as a critical mediator of adaptation. These results clearly demonstrated the ability of MS in attenuating bone loss from the disuse osteopenia, which may hold potential in mitigating skeletal degradation imposed by conditions of disuse, and may serve as a biomechanical intervention in clinic application.  相似文献   

20.
Monte Carlo simulations and a modified Poisson–Boltzmann (MPB) theory are used to investigate the temperature dependence of the capacitance (around the potential of zero charge) of an electric double layer in the presence of surface polarization due to a dielectric boundary. Within the context of the restricted primitive model planar double layer, whose solvent dielectric constant is ε2, the cases when the electrode is an insulator (ε1 = 1), when the electrode and the electrolyte have the same permittivity (ε1 = ε2, no polarization), and when the electrode is a conductor (ε1 → ∞) are studied for the case where the electrolyte concentration is 0.1 M. The simulations reveal a capacitance anomaly, that is, a positive temperature dependence of the capacitance at low temperatures for the former two situations. The MPB theory also shows this effect for these two situations and is in qualitative or better agreement with the simulation data. In these two cases, both the simulations and theory show a dramatic increase of the diffuse layer potential in the temperature regime where capacitance anomaly occurs. However, in the latter situation, where the electrode is metallic, the capacitance always has a negative temperature derivative for the MPB theory and probably also for the simulation data.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号