 共查询到20条相似文献,搜索用时 31 毫秒
1.
PurposeThe log file-based patient dose estimation includes a residual dose estimation error caused by leaf miscalibration, which cannot be reflected on the estimated dose. The purpose of this study is to determine this residual dose estimation error.Methods and materialsModified log files for seven head-and-neck and prostate volumetric modulated arc therapy (VMAT) plans simulating leaf miscalibration were generated by shifting both leaf banks (systematic leaf gap errors: ±2.0, ±1.0, and ±0.5 mm in opposite directions and systematic leaf shifts: ±1.0 mm in the same direction) using MATLAB-based (MathWorks, Natick, MA) in-house software. The generated modified and non-modified log files were imported back into the treatment planning system and recalculated. Subsequently, the generalized equivalent uniform dose (gEUD) was quantified for the definition of the planning target volume (PTV) and organs at risks.ResultsFor MLC leaves calibrated within ±0.5 mm, the quantified residual dose estimation errors that obtained from the slope of the linear regression of gEUD changes between non- and modified log file doses per leaf gap are in head-and-neck plans 1.32 ± 0.27% and 0.82 ± 0.17 Gy for PTV and spinal cord, respectively, and in prostate plans 1.22 ± 0.36%, 0.95 ± 0.14 Gy, and 0.45 ± 0.08 Gy for PTV, rectum, and bladder, respectively.ConclusionsIn this work, we determine the residual dose estimation errors for VMAT delivery using the log file-based patient dose calculation according to the MLC calibration accuracy.  相似文献   

2.
PurposeTo evaluate the utility of the use of iterative cone-beam computed tomography (CBCT) for machine log file-based dose verification during volumetric modulated arc therapy (VMAT) for prostate cancer patients.MethodsAll CBCT acquisition data were used to reconstruct images with the Feldkamp-Davis-Kress algorithm (FDK-CBCT) and the novel iterative algorithm (iCBCT). The Hounsfield unit (HU)-electron density curves for CBCT images were created using the Advanced Electron Density Phantom. The I’mRT and anthropomorphic phantoms were irradiated with VMAT after CBCT registration. Subsequently, fourteen prostate cancer patients received VMAT after CBCT registration. Machine log files and both CBCT images were exported to the PerFRACTION software, and a 3D patient dose was reconstructed. Mean dose for planning target volume (PTV), the bladder, and rectum and the 3D gamma analysis were evaluated.ResultsFor the phantom studies, the variation of HU values was observed at the central position surrounding the bones in FDK-CBCT. There were almost no changes in the difference of doses at the isocenter between measurement and reconstructed dose for planning CT (pCT), FDK-CBCT, and iCBCT. Mean dose differences of PTV, rectum, and bladder between iCBCT and pCT were approximately 2% lower than those between FDK-CBCT and pCT. For the clinical study, average gamma analysis for 2%/2 mm was 98.22% ± 1.07 and 98.81% ± 1.25% in FDK-CBCT and iCBCT, respectively.ConclusionsA similar machine log file-based dose verification accuracy is obtained for FDK-CBCT and iCBCT during VMAT for prostate cancer patients.  相似文献   

3.
AimThis study aimed to evaluate the dosimetric impact of uncorrected yaw rotational error on both target coverage and OAR dose metrics in this patient population.BackgroundRotational set up errors can be difficult to correct in lung VMAT SABR treatments, and may lead to a change in planned dose distributions.Materials and methodsWe retrospectively applied systematic yaw rotational errors in 1° degree increments up to −5° and +5° degrees in 16 VMAT SABR plans. The impact on PTV and OARs (oesophagus, spinal canal, heart, airway, chest wall, brachial plexus, lung) was evaluated using a variety of dose metrics. Changes were assessed in relation to percentage deviation from approved planned dose at 0 degrees.ResultsTarget coverage was largely unaffected with the largest mean and maximum percentage difference being 1.4% and 6% respectively to PTV D98% at +5 degrees yaw.Impact on OARs was varied. Minimal impact was observed in oesophagus, spinal canal, chest wall or lung dose metrics. Larger variations were observed in the heart, airway and brachial plexus. The largest mean and maximum percentage differences being 20.77% and 311% respectively at −5 degrees yaw to airway D0.1cc, however, the clinical impact was negligible as these variations were observed in metrics with minimal initial doses.ConclusionsNo clinically unacceptable changes to dose metrics were observed in this patient cohort but large percentage deviations from approved dose metrics in OARs were noted. OARs with associated PRV structures appear more robust to uncorrected rotational error.  相似文献   

4.
PurposeTo test the performances of a volumetric arc technique named ViTAT (Virtual Tangential-fields Arc Therapy) mimicking tangential field irradiation for whole breast radiotherapy.MethodsViTAT plans consisted in 4 arcs whose starting/ending position were established based on gantry angle distribution of clinical plans for right and left-breast. The arcs were completely blocked excluding the first and last 20°. Different virtual bolus densities and thicknesses were preliminarily evaluated to obtain the best plan performances. For 40 patients with tumor laterality equally divided between right and left sides, ViTAT plans were optimized considering the clinical DVHs for OARs (resulting from tangential field manual planning) to constrain them: ViTAT plans were compared with the clinical tangential-fields in terms of DVH parameters for both PTV and OARs.ResultsDistal angle values were suggested in the ranges [220°,240°] for the right-breast and [115°,135°] for the left-breast cases; medial angles were [60°,40°] for the right side and [295°,315°] for the left side, limiting the risk of collision. The optimal virtual bolus had −500 HU density and 1.5 cm thickness. ViTAT plans generated dose distributions very similar to the tangential-field plans, with significantly improved PTV homogeneity. The mean doses of ipsilateral OARs were comparable between the two techniques with minor increase of the low-dose spread in the range 2–15 Gy (few % volume); contralateral OARs were slightly better spared with ViTAT.ConclusionViTAT dose distributions were similar to tangential-fields. ViTAT should allow automatic plan optimization by developing knowledge-based DVH prediction models of patients treated with tangential-fields.  相似文献   

5.
PurposeTo evaluate the dosimetric impact of uncorrected rotations on the planning target volume (PTV) coverage for early stage non-small cell lung cancer patients treated with stereotactic body radiotherapy using Brainlab ExacTrac image guidance.MethodsTwenty-two patients were retrospectively selected. Two scenarios of uncorrected rotations were simulated with magnitude of 1°, 2°, 3° and 5°: (1) rotation around the treatment isocenter; and (2) roll and yaw rotations around a setup isocenter. The D95 of PTV from recalculated dose on the rotated CT was compared to that from the clinical plan. A logistic regression model was used to predict the probability of dose differences between recalculated and original plans that are less than 2% based on the rotation angle, PTV volume, and distance between the treatment and setup isocenter.ResultsLogistic regression model showed the uncorrected isocentric rotations of up to 2.5° in all directions have negligible dosimetric impact. For non-isocentric rotations, a rotational error of 2° may cause significant under-dose of the PTV. Statistically significant (p < 0.05) parameters in the logistic regression model were angle for isocentric rotations, angle and distance for non-isocentric roll rotations, and angle, distance and the PTV volume for non-isocentric yaw rotations.ConclusionsThe severity of the dose deviations due to uncorrected rotations depends on the type and magnitude of the rotation, the volume of the PTV, and the distance between the treatment and setup isocenter, which should be taken into consideration when making clinical judgment of whether the rotational error could be ignored.  相似文献   

6.
PurposeVMAT delivery technique is currently not applicable to Magnetic Resonance-guided radiotherapy (MRgRT) hybrid systems. Aim of this study is to evaluate an innovative VMAT-like (VML) delivery technique.Material and methodsFirst, planning and dosimetric evaluation of the MRgRT VML treatment have been performed on 10 different disease sites and the results have been compared with the corresponding IMRT plans. Then, in the second phase, 10 of the most dosimetrically challenging locally advanced pancreas treatment plans have been retrospectively re-planned using the VML approach to explore the potentiality of this new delivery technique. Finally, VML robustness was evaluated and compared with the IMRT plans, considering a lateral positioning error of ± 5 mm.ResultsIn phase one, all VML plans were within constraint for all OARs. When PTV coverage is considered, in the 50% of the cases VML PTV coverage is equal or higher than in IMRT plan. In the remaining 50%, the highest target under coverage difference in comparison with IMRT plan is −1.71%. The mean and maximum treatment time differences (VML-IMRT) is 0.2 min and 3.1 min respectively. In phase two, the treatment time variation (VML-IMRT), shows a mean, maximum and minimum variations of 1.3, 4.6 and −0.6 min respectively. All VML plans have a better target coverage if compared with IMRT plans, keeping in any case the OARs constraints within tolerance. VML doesn’t increase plan robustness.ConclusionVMAT-like treatment approach appeared to be an efficient planning solution and it was decided to clinically implement it in daily practice, especially in the frame of hypo fractionated treatments.  相似文献   

7.
AimIn this study, an accuracy survey of intensity-modulated radiation therapy (IMRT) and volumetric arc radiation therapy (VMAT) implementation in radiotherapy centers in Thailand was conducted.BackgroundIt is well recognized that there is a need for radiotherapy centers to evaluate the accuracy levels of their current practices, and use the related information to identify opportunities for future development.Materials and methodsAn end-to-end test using a CIRS thorax phantom was carried out at 8 participating centers. Based on each center's protocol for simulation and planning, linac-based IMRT or VMAT plans were generated following the IAEA (CRP E24017) guidelines. Point doses in the region of PTVs and OARs were obtained from 5 ionization chamber readings and the dose distribution from the radiochromic films. The global gamma indices of the measurement doses and the treatment planning system calculation doses were compared.ResultsThe large majority of the RT centers (6/8) fulfilled the dosimetric goals, with the measured and calculated doses at the specification points agreeing within ±3% for PTV and ±5% for OARS. At 2 centers, TPS underestimated the lung doses by about 6% and spinal cord doses by 8%. The mean percentage gamma pass rates for the 8 centers were 98.29 ± 0.67% (for the 3%/3 mm criterion) and 96.72 ± 0.84% (for the 2%/2 mm criterion).ConclusionsThe 8 participating RT centers achieved a satisfactory quality level of IMRT/VMAT clinical implementation.  相似文献   

8.
We clarified the reconstructed 3D dose difference between two different commercial software programs (Mobius3D v2.0 and PerFRACTION v1.6.4).Five prostate cancer patients treated with IMRT (74 Gy/37 Fr) were studied. Log files and cine EPID images were acquired for each fraction. 3D patient dose was reconstructed using log files (Mobius3D) or log files with EPID imaging (PerFRACTION). The treatment planning dose was re-calculated on homogeneous and heterogeneous phantoms, and log files and cine EPID images were acquired. Measured doses were compared with the reconstructed point doses in the phantom. Next, we compared dosimetric metrics (mean dose for PTV, rectum, and bladder) calculated by Mobius3D and PerFRACTION for all fractions from five patients.Dose difference at isocenter between measurement and reconstructed dose for two software programs was within 3.0% in both homogeneous and heterogeneous phantoms. Moreover, the dose difference was larger using skip arc plan than that using full arc plan, especially for PerFRACTION (e.g., dose difference at isocenter for PerFRACTION: 0.34% for full arc plan vs. −4.50% for skip arc plan in patient 1).For patients, differences in dosimetric parameters were within 1% for almost all fractions. PerFRACTION had wider range of dose difference between first fraction and the other fractions than Mobius3D (e.g., maximum difference: 0.50% for Mobius3D vs. 1.85% for PerFRACTION), possibly because EPID may detect some types of MLC positioning errors such as miscalibration errors or mechanical backlash which cannot be detected by log files, or that EPID data might include image acquisition failure and image noise.  相似文献   

9.
10.
PurposeTo investigate the influence of interfractional changes on the delivered dose of intensity modulated proton (IMPT) and photon plans (IMXT).Methods and materialsFive postoperative head and neck cancer patients, previously treated with tomotherapy at our institute, were analyzed. The planning study is based on megavoltage (MV) control images. For each patient one IMPT plan and one IMXT plan were generated on the first MV-CT and recalculated on weekly control MV-CTs in the actual treatment position. Dose criteria for evaluation were coverage and conformity of the planning target volume (PTV), as well as mean dose to parotids and maximum dose to spinal cord.ResultsConsiderable dosimetric changes were observed for IMPT and IMXT plans. Proton plans showed a more pronounced increase of maximum dose and decrease of minimum dose with local underdosage occurring even in the center of the PTV (worst IMPT vs. IMXT coverage: 66.7% vs. 85.0%). The doses to organs at risk (OARs) increased during the treatment period. However, the OAR doses of IMPT stayed below corresponding IMXT values at any time. For both modalities treatment plans did not necessarily worsen monotonically throughout the treatment.ConclusionsAlthough absolute differences between planned and reconstructed doses were larger in IMPT plans, doses to OARs were higher in IMXT plans. Tumor coverage was more stable in IMXT plans; IMPT dose distributions indicated a high risk for local underdosage during the treatment course.  相似文献   

11.
PurposeThe unique treatment delivery technique provided by magnetic resonance guided radiotherapy (MRgRT) can represent a significant drawback when system fail occurs. This retrospective study proposes and evaluates a pipeline to completely automate the workflow necessary to shift a MRgRT treatment to a traditional radiotherapy linac.Material and methodsPatients undergoing treatment during the last MRgRT system failure were retrospectively included in this study. The core of the proposed pipeline was based on a tool able to mimic the original MR linac dose distribution. The so obtained dose distribution (AUTO) has been compared with the distribution obtained in the conventional radiotherapy linac (MAN). Plan comparison has been performed in terms of time required to obtain the final dose distribution, DVH parameters, dosimetric indices and visual analogue scales scoring by radiation oncologists.ResultsAUTO plans generation has been obtained within 10 min for all the considered cases. All AUTO plans were found to be within clinical tolerance, showing a mean target coverage variation of 1.7% with a maximum value of 4.3% and a minimum of 0.6% when compared with MAN plans. The highest OARs mean variation has been found for rectum V60 (6.7%). Dosimetric indices showed no relevant differences, with smaller gradient measure in favour of AUTO plans. Visual analogue scales scoring has confirmed comparable plan quality for AUTO plans.ConclusionThe proposed workflow allows a fast and accurate generation of automatic treatment plans. AUTO plans can be considered equivalent to MAN ones, with limited clinical impact in the worst-case scenario.  相似文献   

12.
PurposeThis study aims to use GATE/Geant4 simulation code to evaluate the performance of dose calculations with Anisotropic Analytical Algorithm (AAA) in the context of lung SBRT for complex treatments considering images of patients.MethodsFour cases of non-small cell lung cancer treated with SBRT were selected for this study. Irradiation plans were created with AAA and recalculated end to end using Monte Carlo (MC) method maintaining field configurations identical to the original plans. Each treatment plan was evaluated in terms of PTV and organs at risk (OARs) using dose-volume histograms (DVH). Dosimetric parameters obtained from DVHs were used to compare AAA and MC.ResultsThe comparison between the AAA and MC DVH using gamma analysis with the passing criteria of 3%/3% showed an average passing rate of more than 90% for the PTV structure and 97% for the OARs. Tightening the criteria to 2%/2% showed a reduction in the average passing rate of the PTV to 86%. The agreement between the AAA and MC dose calculations for PTV dosimetric parameters (V100; V90; Homogeneity index; maximum, minimum and mean dose; CIPaddick and D2cm) was within 18.4%. For OARs, the biggest differences were observed in the spinal cord and the great vessels.ConclusionsIn general, we did not find significant differences between AAA and MC. The results indicate that AAA could be used in complex SBRT cases that involve a larger number of small treatment fields in the presence of tissue heterogeneities.  相似文献   

13.
PurposeThe aim of this paper is to characterize two different EPID-based solutions for pre-treatment VMAT quality assurance, the 2D portal dosimetry and the 3D projection technique. Their ability to catch the main critical delivery errors was studied.MethodsMeasurements were performed with a linac accelerator equipped with EPID aSi1000, Portal Dose Image Prediction (PDIP), and PerFRACTION softwares. Their performances were studied simulating perturbations of a reference plan through systematic variations in dose values and micromultileaf collimator position. The performance of PDIP, based on 2D forward method, was evaluated calculating gamma passing rate (%GP) between no-error and error-simulated measurements. The impact of errors with PerFRACTION, based on 3D projection technique, was analyzed by calculating the difference between reference and perturbed DVH (%ΔD). Subsequently pre-treatment verification with PerFRACTION was done for 27 patients of different pathologies.ResultsThe sensitivity of PerFRACTION was slightly higher than sensitivity of PDIP, reaching a maximum of 0.9. Specificity was 1 for PerFRACTION and 0.6 for PDIP. The analysis of patients’ DVHs indicated that the mean %ΔD was (1.2 ± 1.9)% for D2%, (0.6 ± 1.7)% for D95% and (−0.0 ± 1.2)% for Dmean of PTV. Regarding OARs, we observed important discrepancies on DVH but that the higher dose variations were in low dose area (<10 Gy).ConclusionsThis study supports the introduction of the new 3D forward projection method for pretreatment QA raising the claim that the visualization of the delivered dose distribution on patient anatomy has major advantages over traditional portal dosimetry QA systems.  相似文献   

14.
PurposeTo compare helical Tomotherapy (HT), two volumetric-modulated arc techniques and conventional fixed-field intensity modulated techniques (S-IMRT) for head-neck (HN) cancers.Methods and materialsEighteen HN patients were considered. Four treatment plans were generated for each patient: HT, S-IMRT optimised with Eclipse treatment planning system and two volumetric techniques using Elekta–Oncentra approach (VMAT) and Varian-RapidArc (RA), using two full arcs. All techniques were optimised to simultaneously deliver 66Gy to PTV1 (GTV and enlarged nodes) and 54Gy to PTV2 (subclinical and electively treated nodes). Comparisons were assessed on several dosimetric parameters and, secondarily, on planned MUs and delivery time.ResultsConcerning PTV coverage, significantly better results were found for HT and RA. HT significantly improved the target coverage both compared to S-IMRT and VMAT. No significant differences were found between S-IMRT and volumetric techniques in terms of dose homogeneity. For OARs, all the techniques were able to satisfy all hard constraints; significantly better results were found for HT, especially in the intermediate dose range (15–30 Gy). S-IMRT reached a significantly better OARs sparing with respect to VMAT and RA. No significant differences were found for body mean dose, excepting higher values of V5–V10 for HT. A reduction of planned MUs and delivery treatment time was found with volumetric techniques.ConclusionsThe objectives of satisfying target coverage and sparing of critical structures were reached with all techniques. S-IMRT techniques were found more advantageous compared to RA and VMAT for OARs sparing. HT reached the best overall treatment plan quality.  相似文献   

15.
AimThe aim is a dosimetric comparison of dynamic conformal arc integrated with the segment shape optimization and variable dose rate (DCA_SSO_VDR) versus VMAT for liver SBRT and interaction of various treatment plan quality indices with PTV and degree of modulation (DoM) for both techniques.BackgroundThe DCA is the state-of-the-art technique but overall inferior to VMAT, and the DCA_SSO_VDR technique was not studied for liver SBRT.Materials and methodsTwenty-five patients of liver SBRT treated using the VMAT technique were selected. DCA_SSO_VDR treatment plans were also generated for all patients in Monaco TPS using the same objective constraint template and treatment planning parameters as used for the VMAT technique. For comparison purpose, organs at risk (OARs) doses and treatment plans quality indices, such as maximum dose of PTV (Dmax%), mean dose of PTV (Dmean%), maximum dose at 2 cm in any direction from the PTV (D2cm%), total monitor units (MU’s), gradient index R50%, degree of modulation (DoM), conformity index (CI), homogeneity index (HI), and healthy tissue mean dose (HTMD) were compared.ResultsSignificant dosimetric differences were observed in several OARs doses and lowered in VMAT plans. The D2cm%, R50%, CI, HI and HTMD are dosimetrically inferior in DCA_SSO_VDR plans. The higher DoM results in poor dose gradient and better dose gradient for DCA_SSO_VDR and VMAT treatment plans, respectively.ConclusionsFor liver SBRT, DCA_SSO_VDR treatment plans are neither dosimetrically superior nor better alternative to the VMAT delivery technique. A reduction of 69.75% MU was observed in DCA_SSO_VDR treatment plans. For the large size of PTV and high DoM, DCA_SSO_VDR treatment plans result in poorer quality.  相似文献   

16.
17.
18.
PurposeTo investigate the dosimetric accuracy of synthetic computed tomography (sCT) images generated by a clinically-ready voxel-based MRI simulation package, and to develop a simple and feasible method to improve the accuracy.Methods20 patients with brain tumor were selected to undergo CT and MRI simulation. sCT images were generated by a clinical MRI simulation package. The discrepancy between planning CT and sCT in CT number and body contour were evaluated. To resolve the discrepancies, an sCT specific CT-relative electron density (RED) calibration curve was used, and a layer of pseudo-skin was created on the sCT. The dosimetric impact of these discrepancies, and the improvement brought about by the modifications, were evaluated by a planning study. Volumetric modulated arc therapy (VMAT) treatment plans for each patient were created and optimized on the planning CT, which were then transferred to the original sCT and the modified-sCT for dose re-calculation. Dosimetric comparisons and gamma analysis between the calculated doses in different images were performed.ResultsThe average gamma passing rate with 1%/1 mm criteria was only 70.8% for the comparison of dose distribution between planning CT and original sCT. The mean dose difference between the planning CT and the original sCT were −1.2% for PTV D95 and −1.7% for PTV Dmax, while the mean dose difference was within 0.7 Gy for all relevant OARs. After applying the modifications on the sCT, the average gamma passing rate was increased to 92.2%. Mean dose difference in PTV D95 and Dmax were reduced to −0.1% and −0.3% respectively. The mean dose difference was within 0.2 Gy for all OAR structures and no statistically significant difference were found.ConclusionsThe modified-sCT demonstrated improved dosimetric agreement with the planning CT. These results indicated the overall dosimetric accuracy and practicality of this improved MR-based treatment planning method.  相似文献   

19.
PurposeDue to limited field size of Magnetic Resonance Linear Accelerators (MR-Linac), some treatments could require a dual-isocenter planning approach to achieve a complete target coverage and thus exploit the benefits of the online adaptation. This study evaluates the dosimetric accuracy of the dual-isocenter intensity modulated radiation therapy (IMRT) delivery technique for MR-Linac.Material and MethodsDual-isocenter multi leaf collimator (MLC) and couch accuracy tests have been performed to evaluate the delivery accuracy of the system. A mono-isocenter plan delivered in clinical practice has then been retrospectively re-planned with dual-isocenter technique. The dual-isocenter plan has been re-calculated and delivered on a 3-dimensional (3D) ArcCHECK phantom and 2-dimensional (2D) films to assess its dosimetric accuracy in terms of gamma analysis. Clinical and planning target volume (CTV and PTV respectively) coverage robustness was then investigated after the introduction of ± 2 mm and ± 5 mm positioning errors by shifting the couch.ResultsMLC and couch accuracy tests confirmed the system accuracy in delivering a dual-isocenter irradiation.2D/3D gamma analysis results occurred always to be above 95% if considered a gamma criteria 1%/2 mm and 1%/1 mm respectively for the 2D and 3D analysis.The mean variations for CTV D98% and PTV V95% were 0.2% and 1.1% respectively when positioning error was introduced separately in each direction, while the maximum observed variations were 0.9% (CTV) and 3.7% (PTV).ConclusionThe dosimetric accuracy of dual-isocenter irradiation has been verified for MR-Linac, achieving accurate and robust treatment strategy and improving dose conformality also in presence of targets whose extension exceeds the nominal maximum field size.  相似文献   

20.
PurposeThis study retrospectively reviewed locally set pass rates/tolerances for COMPASS® pre-treatment quality assurance results for RapidArc prostate plans to determine if these are appropriate. This was performed via quantifying the agreement between treatment planning system calculations and measurements based on absolute dose comparisons (3% tolerance for all dose points) and global gamma index assessment (3%/3 mm criterion for 97% of points).MethodSeventy-three prostate one-arc RapidArc plans, delivered by four dosimetrically matched linacs, were measured using the MatriXX Evolution two-dimensional array and analysed using COMPASS® (v.3, IBA Dosimetry). For the planning target volumes (PTV) considered, the D99%, D50%, D1% and DMean differences were analysed. The percentage volume with gamma greater than 1, average gamma and DMean difference were investigated for all structures. Nine plans were also assessed across the linac fleet to investigate potential linac dependence of results.Results and ConclusionsRegarding PTV DMean differences, all plans fell within the 3% tolerance and mostly within 2%, although there was a relatively small systematic difference. The absolute percentage differences of average and median doses suggested a weak linac dependence of the results which was found to be clinically insignificant. New stricter tolerances were established both for dose comparisons and gamma evaluation. Correlation between the gamma pass rates and the differences in the D99%, D50% and D1% was found to be moderate suggesting that gamma analysis in isolation has questionable clinical meaning and should only be used to indicate outliers for further analysis.  相似文献   