首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
PurposeTo compare normal tissue complication probability (NTCP) and average doses in the bone marrow (BM), obtained for five different radiotherapy delivery and planning strategies of cervical and endometrial cancer.Material/methods50 patients were taken to analysis. For each case, 3 different dose delivery techniques were used: 4-field, X15MV, 3DCRT; 7-field, X6MV, IMRT; and 2-arc, X6MV, VMAT. Two optimization scenarios were used for the IMRT and VMAT plans generation: with (+) and without (−) the inclusion of the BM as an optimized structure. Average doses and dose-volume histogram parameters for the PTV, BM, bladder, rectum, bowels and femoral heads were compared. In addition, the BM doses were analyzed with respect to the PTV and/or volume of the BM, and NTCP for the BM were computed.ResultsThe dose in PTV for evaluated plans was similar. The worst doses in organs at risk were obtained for 3DCRT. Using the BM during the optimization of IMRT and VMAT reduces an average dose in BM without increasing the doses in the bladder, rectum and bowels. Differences between doses in BM for IMRT(+) and VMAT(+) plans were similar while NTCP was lower for VMAT(+). A correlation between average dose in BM and the volume ratio of BM and PTV was found for each technique.ConclusionUsing the BM during the optimization of the IMRT and VMAT plans effectively reduces the dose in BM without increasing the dose in the bladder, rectum and bowels. The VMAT(+) plans were characterized by the lowest NTCP.  相似文献   

2.

Aim

The aim of our study was the dosimetric and physical evaluation of the CK and IMRT treatment plans for 16 patients with localized prostate cancer.

Background

Intensity modulated radiation therapy (IMRT) is one of the recent technical advances in radiotherapy. The prostate is a well suited site to be treated with IMRT. The challenge of accurately delivering the IMRT needs to be supported by new advances such as image-guidance and four-dimensional computed conformal radiation therapy (4DCRT) tomography. CyberKnife (CK) provides real time orthogonal X-ray imaging of the patient during treatment course to follow gold fiducials installed into the prostate and to achieve motion correlation between online acquired X-ray imaging and digital reconstructed radiographs (DRRs) which are obtained from planning computed tomography images by translating and rotating the treatment table in five directions.

Methods and materials

Sixteen IMRT and CK plans were performed to be compared in terms of conformity (CI), heterogeneity indices (HI), percentage doses of 100% (V100), 66% (V66), 50% (V50), 33% (V33) and 10% (V10) volumes of the bladder and rectum. Dose-volume histograms for target and critical organs, (CI) and indices (HI) and isodose lines were analyzed to evaluate the treatment plans.

Results

Statistically significant differences in the percentage rectal doses delivered to V10, V33, and V50 of the rectum were detected in favor of the CK plans (p values; <0.001, <0.001 and 0.019, respectively). The percentage doses for V66 and V100 of the rectum were larger in CK plans (13%, 2% in IMRT and 21%, 3% in CK plans, respectively). Percentage bladder doses for V10 and V33 were significantly lower in CK plans [96% in IMRT vs 48% in CK (p < 0.001) and 34% in IMRT vs 24% in CK (p = 0.047)]. Lower percentage doses were observed for V50, V66 of the bladder for the IMRT. They were 5.4% and 3.45% for IMRT and 13.4% and 8.05% for CK, respectively. Median CI of planning target volume (PTV) for IMRT and CK plans were 0.94 and 1.23, respectively (p < 0.001).

Conclusion

Both systems have a very good ability to create highly conformal volumetric dose distributions. Median HI of PTV for IMRT and CK plans were 1.08 and 1.33, respectively (p < 0.001).  相似文献   

3.
IntroductionThe stereotactic irradiation is a new approach for low-risk prostate cancer. The aim of the present study was to evaluate a schema of stereotactic irradiation of the prostate with an integrated-boost into the tumor.Material and methodsThe prostate and the tumor were delineated by a radiologist on CT/MRI fusion. A 9-coplanar fields IMRT plan was optimized with three different dose levels: 1) 5 × 6.5 Gy to the PTV1 (plan 1), 2) 5 × 8 Gy to the PTV1 (plan 2) and 3) 5 × 6.5 Gy on the PTV1 with 5 × 8 Gy on the PTV2 (plan 3). The maximum dose (MaxD), mean dose (MD) and doses received by 2% (D2), 5% (D5), 10% (D10) and 25% (D25) of the rectum and bladder walls were used to compare the 3 IMRT plans.ResultsA dose escalation to entire prostate from 6.5 Gy to 8 Gy increased the rectum MD, MaxD, D2, D5, D10 and D25 by 3.75 Gy, 8.42 Gy, 7.88 Gy, 7.36 Gy, 6.67 Gy and 5.54 Gy. Similar results were observed for the bladder with 1.72 Gy, 8.28 Gy, 7.01 Gy, 5.69 Gy, 4.36 Gy and 2.42 Gy for the same dosimetric parameters. An integrated SBRT boost only to PTV2 reduced by about 50% the dose difference for rectum and bladder compared to a homogenous prostate dose escalation. Thereby, the MD, D2, D5, D10 and D25 for rectum were increased by 1.51 Gy, 4.24 Gy, 3.08 Gy, 2.84 Gy and 2.37 Gy in plan 3 compared to plan 1.ConclusionsThe present planning study of an integrated SBRT boost limits the doses received by the rectum and bladder if compared to a whole prostate dose escalation for SBRT approach.  相似文献   

4.

Aim

This study compared the dosimetric impact between prostate IMRT and VMAT due to patient''s weight loss.

Background

Dosimetric variation due to change of patient''s body contour is difficult to predict in prostate IMRT and VMAT, since a large number of small and irregular segmental fields is used in the delivery.

Materials and methods

Five patients with prostate volumes ranging from 32.0 to 86.5 cm3 and a heterogeneous pelvis phantom were used for prostate IMRT and VMAT plans using the same set of dose–volume constraints. Doses in IMRT and VMAT plans were recalculated with the patient''s and phantom''s body contour reduced by 0.5–2 cm to mimic size reduction. Dose coverage/criteria of the PTV and CTV and critical organs (rectum, bladder and femoral heads) were compared between IMRT and VMAT.

Results

In IMRT plans, increases of the D99% for the PTV and CTV were equal to 4.0 ± 0.1% per cm of reduced depth, which were higher than those in VMAT plans (2.7 ± 0.24% per cm). Moreover, increases of the D30% of the rectum and bladder per reduced depth in IMRT plans (4.0 ± 0.2% per cm and 3.5 ± 0.5% per cm) were higher than those of VMAT (2.2 ± 0.2% per cm and 2.0 ± 0.6% per cm). This was also true for the increase of the D5% for the right femoral head in a patient or phantom with size reduction due to weight loss.

Conclusions

VMAT would be preferred to IMRT in prostate radiotherapy, when a patient has potential to suffer from weight loss during the treatment.  相似文献   

5.
PurposeTo evaluate the SharePlan software in conversion of helical tomotherapy (HT) to a step and shoot IMRT (sIMRT) for patients with high-risk prostate cancer and hip prosthesis.MethodsAnalysis was performed for 16 consecutive patients treated on HT. The HT plans were converted to sIMRT plans. 3DCRT, sliding window IMRT (dIMRT) and VMAT plans for a c-arm linear accelerator (CLA) were created manually. The doses in planning target volume (PTV), bladder, rectum, bowels, femoral heads and hip prosthesis were compared using: (i) a qualitative analysis of doses in averaged dose–volume histograms, (ii) a quantitative, ranking procedure performed for each patient separately, and (iii) statistical testing based on the Friedman ANOVA and Nemenyi method.ResultsFor the bladder, rectum, and femoral head, the best dose distributions were observed for HT and sIMRT and then for dIMRT, VMAT, and finally for 3DCRT (p-values were, respectively, 0.002, 0.004 and p = 0.024). For the bowels, 3DCRT was significantly different from the rest of the techniques (p = 0.009). For the hip prosthesis, the differences were only between 3DCRT and HT/sIMRT (p = 0.038).ConclusionThe SharePlan is an efficient tool for the conversion of HT plans for patients with prostate cancer and hip prosthesis. Dose distributions in sIMRT and in HT plans are similar and are generally better than in CLA plans.  相似文献   

6.
AimTo investigate the predictive value of convenience of rectum dosimetry with Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC) dose limits, maximum rectum dose (Dmax), total rectal volume (TVrectum), rectal volume included in PTV (VrectumPTV) on Grade 2–3 acute rectal toxicity for utilization in clinical practice.BackgroundNumerous previous data have reported frequent acute proctitis after external-beam RT of prostate cancer. Predicting toxicity limited with dose information is inadequate in clinical practice due to comorbidities and medications used.Materials and MethodSixty-four non-metastatic prostate cancer patients treated with IMRT were enrolled. Patients were treated to a total dose of 70–76 Gy. Rectal dose volume histograms (DVH) of all patients were evaluated retrospectively, and a QUANTEC Score between 0 and 5 was calculated for each patient. The correlation between the rectal DVH data, QUANTEC score, TVrectum, VrectumPTV, rectum Dmax and Grade 2–3 rectal toxicity was investigated.ResultsIn the whole group grade 1, 2 and 3 acute rectal toxicities were 25%, 18.8% and 3.1%, respectively. In the DVH data, rectum doses of all patients were under RTOG dose limits. Statistically significant correlation was found between grade 2–3 rectal toxicity and TVrectum (p = 0,043); however. It was not correlated with QUANTEC score, VrectumPTV and Dmax.ConclusionOur results were not able to show any significant correlation between increasing convenience with QUANTEC limits and lower rectal toxicity. Conclusively, new dosimetric definitions are warranted to predict acute rectal toxicity more accurately in prostate cancer patients during IMRT treatment.  相似文献   

7.
8.

The aim of this study was to investigate the effect of a hybrid technique which results from combining intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) for the treatment of cervical cancer patients. Plans made with the hybrid technique and pure IMRT and VMAT were retrospectively compared in 20 patients with cervical cancer at different stages. All plans were made using the same contours based on the original computed tomography (CT) scans. Conformity (CI) and homogeneity (HI) indices of the planning target volumes (PTVs) were calculated for each technique in order to evaluate plan quality. All techniques were compared in terms of dose to organs at risk (OARs), number of monitor units (MUs) and treatment time. It turned out that plans made with the hybrid technique had improved dose conformity and homogeneity compared to plans made only with IMRT and VMAT (p < 0.001). Regarding the OARs, the maximum dose (Dmax) delivered to the bladder, rectum and femoral heads was lower for the hybrid plans compared to the IMRT and VMAT plans (p < 0.001). The volumes irradiated to doses of 50 Gy (V50Gy) for rectum, bladder and bowel were lower for the hybrid plans (p < 0.001, p = 0.002). Furthermore, the treatment time and MU values for the hybrid plans were found to be between of the values for the IMRT and VMAT plans. It is concluded that, as compared to IMRT and VMAT plans, the hybrid plan technique allowed a better conformity and homogeneity for the dose distribution in the PTV and a dose reduction to the OARs.

  相似文献   

9.
PurposeThe purpose of this work was to present a new single-arc mixed photon (6&18MV) VMAT (SAMP) optimization framework that concurrently optimizes for two photon energies with corresponding partial arc lengths.Methods and materialsOwing to simultaneous optimization of energy dependent intensity maps and corresponding arc locations, the proposed model poses nonlinearity. Unique relaxation constraints based on McCormick approximations were introduced for linearization. Energy dependent intensity maps were then decomposed to generate apertures. Feasibility of the proposed framework was tested on a sample of ten prostate cancer cases with lateral separation ranging from 34 cm (case no.1) to 52 cm (case no.6). The SAMP plans were compared against single energy (6MV) VMAT (SE) plans through dose volume histograms (DVHs) and radiobiological parameters including normal tissue complication probability (NTCP) and equivalent uniform dose (EUD).ResultsThe contribution of higher energy photon beam optimized by the algorithm demonstrated an increase for cases with a lateral separation >40 cm. SAMP–VMAT notably improved bladder and rectum sparing in large size cases. Compared to single energy, SAMP–VMAT plans reduced bladder and rectum NTCP in cases with large lateral separation. With the exception of one case, SAMP–VMAT either improved or maintained femoral heads compared to SE–VMAT. SAMP–VMAT reduced the nontarget tissue integral dose in all ten cases.ConclusionsA single-arc VMAT optimization framework comprising mixed photon energy partial arcs was presented. Overall results underline the feasibility and potential of the proposed approach for improving OAR sparing in large size patients without compromising the target homogeneity and coverage.  相似文献   

10.
Aim and backgroundThe change in the prostate size for radiotherapy has not yet been elucidated. The coverage of radiation dose is affected by changes in the prostate size. We evaluated the changes in the prostate, rectum, and bladder wall sizes during IMRT of fraction 2 Gy/day using MRI.Materials and methodsTwenty-four patients with prostate cancer were enrolled in this study. MRI was performed at three time points. While the initial MRI was performed before the start of radiotherapy (RT), the second MRI was performed at 38 Gy (range: 36–40 Gy), which represented the halfway point of the RT course. The last MRI was performed on the day of completion of the RT course (76 Gy; range: 74–78 Gy). We estimated the prostate, rectum, and bladder wall sizes at three time points.ResultsWe observed no significant difference between the estimated sizes of the prostate during RT in all three phases. In addition, the volume of the rectal wall remained unchanged in all phases. However, the volume of the bladder wall significantly decreased from the initial to the last time points. Furthermore, the standard deviation (SD) obtained by subtracting the final size from the initial one was large (mean, 30.1; SD, 10.1).ConclusionsThe volume of the bladder wall decreased during IMRT. The range of subtraction of the volume of the bladder wall was extensive. Thus, the estimation of the bladder wall may be useful to reduce the inter-fraction variation.  相似文献   

11.
AimThis study aimed to investigate whether IMRT using VMAT is a viable and safe solution in dose escalated RT in these patients.BackgroundAn increasing number of prostate cancer patients are elderly and have hip prostheses. These implants pose challenges in radiotherapy treatment planning. Although intensity modulated radiotherapy (IMRT) is commonly used, there is a lack of clinical studies documenting its efficacy and toxicities in this subgroup of patients.Materials and methodsThe data from 23 patients with hip prostheses and non-metastatic prostate cancer treated with VMAT (volumetric modulated arc therapy) between 2009 and 2011, were retrospectively analyzed. Baseline characteristics, treatment details and outcome data were collected on all patients. The median follow up was 40.9 months. MRI-CT image fusion was performed and the treatment plans were created using RapidArc™ (RA) techniques utilizing 1 or 2 arcs and 10 MV photon beams.Results96% of patients were treated with a dose of 72 Gy/32 fractions over 44 days. 21/23 plans met the PTV targets. The mean homogeneity index was 1.07. 20/23 plans met all OAR constraints (rectum, bladder). Two plans deviated from rectal constraints, four from bladder constraints; all were classed as minor deviations. One patient experienced late grade 3 genitourinary toxicity. Three other patients experienced late grade 2 or lower gastrointestinal toxicity. One patient had biochemical failure and one had a non-prostate cancer related death.ConclusionsVMAT provides an elegant solution to deliver dose escalated RT in patients with unilateral and bilateral hip replacements with minimal acute and late toxicities.  相似文献   

12.
AimTo compare the radiotherapy technique used in a randomised trial with VMAT and an in-house technique for prostate cancer.BackgroundTechniques are evolving with volumetric modulated arc therapy (VMAT) commonly used. The CHHiP trial used a 3 PTV forward planned IMRT technique (FP_CH). Our centre has adopted a simpler two PTV technique with locally calculated margins.Materials and methods25 patients treated with FP_CH to 60 Gy in 20 fractions were re-planned with VMAT (VMAT_CH) and a two PTV protocol (VMAT_60/52 and VMAT_60/48). Target coverage, conformity index (CI), homogeneity index (HI), monitor units (MU) and dose to the rectum, bladder, hips and penile bulb were compared.ResultsPTV coverage was high for all techniques. VMAT_CH plans had better CI than FP_CH (p   0.05). VMAT_60/52/48 plans had better CI than VMAT_CH. FP_CH had better HI and fewer MU than VMAT (p   0.05). More favourable rectum doses were found for VMAT _CH than FP_CH (V48.6, V52.8, V57, p   0.05) with less difference for bladder (p   0.05). Comparing VMAT_CH to VMAT_60/52/48 showed little differences for the bladder and rectum but VMAT_CH had larger penile bulb doses (V40.8, V48.6, mean, D2, p   0.05). Femoral head doses (V40.8) were similarly low for all techniques (p = ≥ 0.05).ConclusionVMAT produced more conformal plans with smaller rectum doses compared to FP_CH albeit worse HI and more MU. VMAT_60/52 and VMAT_60/48 plans had similar rectal and bladder doses to VMAT_CH but better CI and penile bulb doses which may reduce toxicity.  相似文献   

13.
14.
AimThe main purpose of this study is to perform a dosimetric comparison on target volumes and organs at risks (OARs) between prostate intensity modulated treatment plans (IMRT) optimized with different multileaf collimators (MLCs).BackgroundThe use of MLCs with a small leaf width in the IMRT optimization may improve conformity around the tumor target whilst reducing the dose to normal tissues.Materials and methodsTwo linacs mounting MLCs with 5 and 10 mm leaf-width, respectively, implemented in Pinnacle3 treatment planning system were used for this work. Nineteen patients with prostate carcinoma undergoing a radiotherapy treatment were enrolled. Treatment planning with different setup arrangements (7 and 5 beams) were performed for each patient and each machine. Dose volume histograms (DVHs) cut-off points were used in the treatment planning comparison.ResultsComparable planning target volume (PTV) coverage was obtained with 7- and 5-beam configuration (both with 5 and 10 mm MLC leaf-width). The comparison of bladder and rectum DVH cut-off points for the 5-beam arrangement shows that 52.6% of the plans optimized with a larger leaf-width did not satisfy at least one of the OARs’ constraints. This percentage is reduced to 10.5% for the smaller leaf-width. If a 7-beam arrangement is used the value of 52.6% decreases to 21.1% while the value of 10.5% remains unchanged.ConclusionMLCs collimators with different widths and number of leaves lead to a comparable prostate treatment planning if a proper adjustment is made of the number of gantry angles.  相似文献   

15.
AimTo analyse the interfractional bladder and rectal volume changes and the influence on prostate position.BackgroundInterfractional displacement of prostate due to variation in bladder and rectal volume is usual. It is only rational to study the bladder and rectal volume changes and their effects on prostate position during intensity modulated radiotherapy of prostate cancer.Materials and MethodsA prospective study was conducted on twenty patients with localized prostate cancer during the first phase of radiotherapy, where 50 gray in 25 fractions was delivered by the IMRT technique with daily cone beam computed tomography Bladder and rectum volumes were delineated on CBCT images and their volumes were noted. Prostate position was noted on each set of CBCT images with respect to specific reference points defined on the ileum and coccyx, and daily prostate displacement was noted.ResultsMean setup errors in vertical, longitudinal and lateral directions were noted as 1.49, 0.498 and 0.17 cm, respectively. Mean change in bladder and rectal volumes in daily CBCT images with respect to that on the first day CT images was noted as 101.94 and 10.22, respectively. Mean lateral and vertical displacement in prostate position was noted as 0.53 and 0.49 cm respectively. No considerable changes in dosimetric parameters were observed because of bladder and rectal volume changes.ConclusionsDaily CBCT should be done for accurate treatment delivery by the IMRT technique for prostate radiotherapy as prostate shifts physiologically with changes in rectal and bladder volumes.  相似文献   

16.

Aim

To compare DVHs for OARs in two different positions – prone and supine – for prostate cancer patients irradiated with a Tomotherapy unit.

Background

In the era of dose escalation, the choice of optimal patient immobilization plays an essential role in radiotherapy of prostate cancer.

Materials and methods

The study included 24 patients who were allocated to 3 risk groups based on D’Amico criteria; 12 patients represented a low or intermediate and 12 a high risk group.For each patient two treatment plans were performed: one in the supine and one in the prone position. PTV included the prostate, seminal vesicles and lymph nodes for the high risk group and the prostate and seminal vesicles for the intermediate or low risk groups. DVHs for the two positions were compared according to parameters: Dmean, D70, D50 and D20 for the bladder and rectum and Dmean, D10 for the intestine. The position accuracy was verified using daily MVCT.

Results

Prone position was associated with lower doses in OARs, especially in the rectum. Despite the fact that in the entire group the differences between tested parameters were not large, the Dmean and D10 for the intestine were statistically significant. In the case of irradiation only to the prostate and seminal vesicles, the prone position allowed for substantial reduction of all tested DVH parameters in the bladder and rectum, except D20 for bladder. Moreover, the Dmean and D50 parameter differences for the bladder were statistically significant.No significant differences between positions reproducibility were demonstrated.

Conclusion

In patients irradiated to prostate and seminal vesicles, the prone position may support sparing of the rectum and bladder.The reproducibility of position arrangement in both positions is comparable.  相似文献   

17.
为探讨NSCLC脑部转移瘤调强放疗与适形放疗的剂量特点,本研究选取57例非小细胞肺癌脑转移瘤患者,其中单个脑转移灶患者5例,多个脑转移灶患者52例,分别设计全脑放疗+适形放疗与调强放疗计划,用均匀指数(HI)和适形指数(CI)评价靶区剂量,危及器官(OAR)剂量用近似最大剂量D2%(串联)和中位剂量D50%(并联)进行评价。研究发现,单个脑转移灶IMRT与WBRT+CRT比较中,CI为(PTV,(0.80±0.15) cGy,(0.34±0.19) cGy, p=0.00),HI为(PTV,(0.52±0.03) c Gy,(0.71±0.12) cGy, p=0.24),两者OARs剂量比较:脑干为((4 348±236) cGy,(4 593±149) cGy, p=0.01),脑垂体为((4 258±166) cGy,(4 581±123) cGy, p=0.02);在多个脑转移灶中,IMRT与WBRT+CRT比,较CI为(PTV,(0.59±0.33) cGy,(0.49±0.27) cGy, p=0.03),HI为(PTV,(0.93±0.01) cGy,(0.58±0.03) cGy, p=0.19),两者OARs剂量比较:脑干为((4 946±132) cGy,(4 843±196) cGy, p=0.51),脑垂体为((4 597±180) cGy,(4 705±149) cGy, p=0.70)。本研究的结果说明,单个脑转移灶患者,IMRT较WBRT+CRT有更好的靶区适形性、稍差的靶区异质性,脑干和垂体的IMRT剂量低于WBRT+CRT,而眼球、晶体的剂量两者差别不明显。多个脑转移灶患者,IMRT较WBRT+CRT有更好的靶区适形性、稍差的靶区异质性,而OARs剂量,IMRT较WBRT+CRT差异不明显。在临床实践过程中,应当根据患者不同的病灶情况选择合适的放疗方案,以获取更优的临床治疗效果。  相似文献   

18.
PurposeDeep learning has shown great efficacy for semantic segmentation. However, there are difficulties in the collection, labeling and management of medical imaging data, because of ethical complications and the limited number of imaging studies available at a single facility.This study aimed to find a simple and low-cost method to increase the accuracy of deep learning semantic segmentation for radiation therapy of prostate cancer.MethodsIn total, 556 cases with non-contrast CT images for prostate cancer radiation therapy were examined using a two-dimensional U-Net. Initially, all slices were used for the input data. Then, we removed slices of the cranial portions, which were beyond the margins of the bladder and rectum. Finally, the ground truth labels for the bladder and rectum were added as channels to the input for the prostate training dataset.ResultsThe highest mean dice similarity coefficients (DSCs) for each organ in the test dataset of 56 cases were 0.85 ± 0.05, 0.94 ± 0.04 and 0.85 ± 0.07 for the prostate, bladder and rectum, respectively. Removal of the cranial slices from the original images significantly increased the DSC of the rectum from 0.83 ± 0.09 to 0.85 ± 0.07 (p < 0.05). Adding bladder and rectum information to prostate training without removing the slices significantly increased the DSC of the prostate from 0.79 ± 0.05 to 0.85 ± 0.05 (p < 0.05).ConclusionsThese cost-free approaches may be useful for new applications, which may include updated models and datasets. They may be applicable to other organs at risk (OARs) and clinical targets such as elective nodal irradiation.  相似文献   

19.
PurposeTreatment plans manually generated in clinical routine may suffer from variations and inconsistencies in quality. Using such plans for validating a DVH prediction algorithm might obscure its intrinsic prediction accuracy. In this study we used a recently published large database of Pareto-optimal prostate cancer plans to assess the prediction accuracy of a commercial knowledge-based DVH prediction algorithm, RapidPlan. The database plans were consistently generated with automated planning using an independent optimizer, and can be considered as aground truth of plan quality.MethodsPrediction models were generated using training sets with 20, 30, 45, 55 and 114 Pareto-optimal plans. Model-20 and Model-30 were built using 5 groups of randomly selected training patients. For 60 independent Pareto-optimal validation plans, predicted and database DVHs were compared.ResultsFor model-114, differences between predicted and database mean doses of more than ± 10% in rectum, anus and bladder, occurred for 23.3%, 55.0%, and 6.7% of the validation plans, respectively. For rectum V65Gy and V75Gy, differences outside the ±10% range were observed in 21.7% and 70.0% of validation plans, respectively. For 61.7% of validation plans, inaccuracies in predicted rectum DVHs resulted in a deviation in predicted NTCP for rectal bleeding outside ±10%. With smaller training sets the DVH prediction performance deteriorated, showing dependence on the selected training patients.ConclusionEven when analysed with Pareto-optimal plans with highly consistent quality, clinically relevant deviations in DVH predictions were observed. Such deviations could potentially result in suboptimal plans for new patients. Further research on DVH prediction models is warranted.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏