1.
AimThe aim of this study was to determine the Inflection Points (IPs) of flattening filter free (FFF) CyberKnife dose profiles for cone-based streotactic radiotherapy. In addition, dosimetric field sizes were determined.BackgroundThe increased need for treatment in the early stages of cancer necessitated the treatment of smaller tumors. However, efforts in that direction required the modeling accuracy of the beam. Removal of the flattening filter (FF) from the path of x-ray beam has provided the solution to those efforts, but required a different normalization approach for the beam to ensure the delivery of the dose accurately. As a solution, researchers proposed a normalization factor based on IPs.Materials and methodsMeasurements using microDiamond (PTW 60019), Diode SRS (PTW 60018) and Monte Carlo (MC) calculations of dose profiles were completed at SAD 80 cm and 5 cm depth for 15–60 mm cones. Performance analysis of detectors with respect to MC calculation was carried out. Gamma evaluation method was used to determine achievable acceptability criteria for FFF CyberKnife beams.ResultsAcceptability within (3%–0.5 mm) was found to be anachievable criterion for all dose profile measurements of the cone beams used in this study. To determine the IP, the first and second derivatives of the dose profile were determined via the cubic spline interpolation technique.ConclusionDerivatives of the interpolated profiles showed that locations of IPs and 50% isodose points coincide.  相似文献   

2.
PurposeNew promising detectors are available for measuring small field size output factors (OFs). This study focused on a multicenter evaluation of two new generation detectors for OF measurements on CyberKnife systems.MethodsPTW-60019 microDiamond and W1 plastic scintillation detector (PSD) were used to measure OFs on eight CyberKnife units of various generations for 5–60 mm fixed cones. MicroDiamond and PSD OF were compared to routinely used silicon diodes data corrected applying published Monte Carlo (MC) factors. PSD data were corrected for Čerenkov Light Ratio (CLR). The uncertainties related to CLR determination were estimated.ResultsConsidering OF values averaged over all centers, the differences between MC corrected diode and the other two detectors were within 1.5%. MicroDiamond exhibited an over-response of 1.3% at 7.5 mm and a trend inversion at 5 mm with a difference of 0.2%. This behavior was consistent among the different units. OFs measured by PSD slightly under-responded compared to MC corrected diode for the smaller cones and the differences were within 1%. The observed CLR variability was 2.5% and the related variation in OF values was 1.9%.ConclusionThis study indicates that CyberKnife microDiamond OF require corrections below 2%. The results are enhanced by the consistency observed among different units. Scintillator shows a good agreement to MC corrected diode but CLR determination remains critical requiring further investigations. The results emphasized the value of a multi-center validation over a single center approach.  相似文献   

3.
AimPatient setup errors were aimed to be reduced in radiotherapy (RT) of head-and-neck (H&N) cancer. Some remedies in patient setup procedure were proposed for this purpose.BackgroundRT of H&N cancer has challenges due to patient rotation and flexible anatomy. Residual position errors occurring in treatment situation and required setup margins were estimated for relevant bony landmarks after the remedies made in setup process and compared with previous results.Materials and methodsThe formation process for thermoplastic masks was improved. Also image matching was harmonized to the vertebrae in the middle of the target and a 5 mm threshold was introduced for immediate correction of systematic errors of the landmarks. After the remedies, residual position errors of bony landmarks were retrospectively determined from 748 orthogonal X-ray images of 40 H&N cancer patients. The landmarks were the vertebrae C1–2, C5–7, the occiput bone and the mandible. The errors include contributions from patient rotation, flexible anatomy and inter-observer variation in image matching. Setup margins (3D) were calculated with the Van Herk formula.ResultsSystematic residual errors of the landmarks were reduced maximally by 49.8% (p  0.05) and the margins by 3.1 mm after the remedies. With daily image guidance the setup margins of the landmarks were within 4.4 mm, but larger margins of 6.4 mm were required for the mandible.ConclusionsRemarkable decrease in the residual errors of the bony landmarks and setup margins were achieved through the remedies made in the setup process. The importance of quality assurance of the setup process was demonstrated.  相似文献   

4.
PurposeThe aim of the present work was to evaluate small field size output factors (OFs) using the latest diamond detector commercially available, PTW-60019 microDiamond, over different CyberKnife systems. OFs were measured also by silicon detectors routinely used by each center, considered as reference.MethodsFive Italian CyberKnife centers performed OFs measurements for field sizes ranging from 5 to 60 mm, defined by fixed circular collimators (5 centers) and by Iris variable aperture collimator (4 centers). Setup conditions were: 80 cm source to detector distance, and 1.5 cm depth in water. To speed up measurements two diamond detectors were used and their equivalence was evaluated. MonteCarlo (MC) correction factors for silicon detectors were used for comparing the OF measurements.ResultsConsidering OFs values averaged over all centers, diamond data resulted lower than uncorrected silicon diode ones. The agreement between diamond and MC corrected silicon values was within 0.6% for all fixed circular collimators. Relative differences between microDiamond and MC corrected silicon diodes data for Iris collimator were lower than 1.0% for all apertures in the totality of centers. The two microDiamond detectors showed similar characteristics, in agreement with the technical specifications.ConclusionsExcellent agreement between microDiamond and MC corrected silicon diode detectors OFs was obtained for both collimation systems fixed cones and Iris, demonstrating the microDiamond could be a suitable detector for CyberKnife commissioning and routine checks. These results obtained in five centers suggest that for CyberKnife systems microDiamond can be used without corrections even at the smallest field size.  相似文献   

5.
6.
The present study is the first report demonstrating that ionic liquids consisting of cholinium cations and linear carboxylate anions ([Ch][CA] ILs) can be used for pretreatment of lignocellulosic materials to enhance subsequent enzymatic saccharification. Six variants of [Ch][CA] ILs were systematically prepared by combining cholinium cations with linear monocarboxylate anions ([CnH2n+1–COO], n = 0–2) or dicarboxylate anions ([HOOC–CnH2n+1–COO], n = 0–2). These [Ch][CA] ILs were analyzed for their toxicity to yeast cell growth and their ability to pretreat kenaf powder for subsequent enzymatic saccharification. When assayed against yeast growth, the EC50 for choline acetate ([Ch][OAc]) was 510 mM, almost one order of magnitude higher than that for 1-ethyl-3-methylimidazolium acetate ([Emim][OAc]). The cellulose saccharification ratio after pretreatment at 110 °C for 16 h with [Ch][OAc] (100.6%) was almost comparable with that after pretreatment with [Emim][OAc]. Therefore, [Ch][OAc] is a biocompatible alternative to [Emim][OAc] for lignocellulosic material pretreatment.  相似文献   

7.
PurposeThe aim of the present investigation was to evaluate the dosimetric variation regarding the analytical anisotropic algorithm (AAA) relative to other algorithms in lung stereotactic body radiation therapy (SBRT). We conducted a multi-institutional study involving six institutions using a secondary check program and compared the AAA to the Acuros XB (AXB) in two institutions.MethodsAll lung SBRT plans (128 patients) were generated using the AAA, pencil beam convolution with the Batho (PBC-B) and adaptive convolve (AC). All institutions used the same secondary check program (simple MU analysis [SMU]) implemented by a Clarkson-based dose calculation algorithm. Measurement was performed in a heterogeneous phantom to compare doses using the three different algorithms and the SMU for the measurements. A retrospective analysis was performed to compute the confidence limit (CL; mean ± 2SD) for the dose deviation between the AAA, PBC, AC and SMU. The variations between the AAA and AXB were evaluated in two institutions, then the CL was acquired.ResultsIn comparing the measurements, the AAA showed the largest systematic dose error (3%). In calculation comparisons, the CLs of the dose deviation were 8.7 ± 9.9% (AAA), 4.2 ± 3.9% (PBC-B) and 5.7 ± 4.9% (AC). The CLs of the dose deviation between the AXB and the AAA were 1.8 ± 1.5% and −0.1 ± 4.4%, respectively, in the two institutions.ConclusionsThe CL of the AAA showed much larger variation than the other algorithms. Relative to the AXB, larger systematic and random deviations still appeared. Thus, care should be taken in the use of AAA for lung SBRT.  相似文献   

8.
IntroductionAim of the present study is to evaluate homolateral and contralateral hippocampus (H-H, C-H, respectively) dose during Fractionated Stereotactic Radiotherapy (FSRT) or Radiosurgery (SRS) for brain metastases (BM).Materials & methodsPatients with BM < 5, size  30 mm, KPS  80 and a life expectancy > 3 months, were considered for SRS/FSRT (total dose 15–30 Gy, 1–5 fractions). For each BM, a Flattening Filter Free (FFF) Volumetric Modulated Arc Therapy (VMAT) plan was generated with one or two arcs. Hippocampi were not considered during optimizations phase and were contoured and evaluated retrospectively in terms of dose: the Dmedian, Dmean, D0.1cc and the V1Gy, V2Gy, V5Gy and V10Gy were analyzed.ResultsFrom April 2014 to December 2015, 81 BM were treated with FFF-FSRT/SRS. For the H-H, the average values of Dmedian, Dmean and D0.1cc were 1.5Gy, 1.54Gy and 2.2Gy, respectively, while the V1Gy, V2Gy, V5Gy and V10Gy values were 25%, 8.9%, 8.9% and 2.1%, respectively. For the C–H, the average Dmedian, Dmean and D0.1 cc were 0.7Gy, 0.7Gy, 0.9Gy, respectively, while the average values of V1Gy, V2Gy, V5Gy and V10Gy were 18%, 10.2%, 2.8% and 1.4%, respectively. Tumor dimension, tumor cranial-caudal length and the distance between BM and H-H were correlated to Dmedian, Dmean and D0.1cc. For C-H, only the distance from PTV was correlated with a dose reduction.ConclusionDuring FFF-FSRT/SRS, hippocampus received a negligible dose. Despite its clinical significance is still under evaluation, in patients with a long life expectancy, H-H should be considered during Linac-based FSRT/SRS.  相似文献   

9.
ObjectiveTo evaluate expression of somatostatin receptor subtypes 2 and 5 (SSTR 2 and 5) by RT/PCR and immunohistochemistry (IHC) in GH-secreting adenomas, seeking correlations with response to octreotide.MethodsSSTR2 and 5 expression was tested by IHC (n = 37), RT/PCR (n = 36) or both (n = 13) in GH-secreting adenomas from 60 patients with acromegaly who had undergone pituitary surgery; 36 had been treated preoperatively with octreotide LAR for 3–6 months, and were categorized as responders (achievement of GH <2.5 ng/mL and a normal age-adjusted IGF-1), partial responders (GH and IGF-1 reduction >50% and >30%, respectively) or non-responders. IHC was performed on a tissue microarray using specific antibodies directed to the carboxyl terminus of SSTR2 and 5.ResultsSSTR5 was the predominantly expressed receptor subtype by both IHC and RT/PCR in all tumors tested, regardless of whether they came from octreotide-naïve, octreotide-responsive, or octreotide-resistant patients. Immunostaining was concentrated in the cytoplasm. Neither SSTR2 nor SSTR5 expression correlated with baseline or post-octreotide GH or IGF-1 levels or tumor volume by either method. The agreement rate between RT/PCR and IHC was 77% in all 13 adenomas in which both methods were used.ConclusionExpression of these receptors does not guarantee an adequate response to somatostatin analogs; other functional aspects of this interaction, such as receptor homo- and heterodimerization, and the resulting signaling cascade, probably play a role in determining whether a patient will respond or not to these agents.  相似文献   

10.
AimTo review the treatment results and identify prognostic factors for disease control and survival in a cohort of nasopharyngeal carcinoma (NPC) patients from a non-endemic population in Slovenia, diagnosed between 1990 and 2003.BackgroundIn Caucasians, nasopharyngeal carcinoma is a rare malignant tumor. Its diagnosis and treatment are complex and have been dramatically impacted by recent technological advances.Materials and methodsIn the Cancer Registry of Slovenia database, a total of 126 patients with NPC were identified, 93 of whom were available for analysis. All patients were treated with conventional two-dimensional radiotherapy (RT) and 29.3% underwent chemotherapy (ChT).ResultsThe median follow-up time for those alive at the last follow-up examination was 74.5 months. Disease recurred locally in 17 patients, regionally in 4 patients and at distant sites in 18 patients, resulting in 5-year locoregional control (LRC), distant failure-free survival (DFFS) and disease-free survival (DFS) of 73.7%, 78.6% and 59.3%, respectively. Disease-specific survival at 5 years was 59% and overall survival (OS) was 49.7%. In a multivariate analysis, LRC was favorably affected (P < 0.05) by an undifferentiated histology (hazard ratio [HR] = 2.86), DFFS through the absence of neck metastases (HR = 0.28), DFS by younger age (HR = 0.46), and more intensive RT (expressed as the isoeffective dose, EQD2,T; HR = 2.08). The independent prognosticator for OS was age (≤55 years vs. >55 years, HR = 0.39); in the ≤55 years subgroup, an improved OS was connected to a more intensive RT regimen of EQD2,T  66 Gy (HR = 4.17).ConclusionsOur results confirm an independent and favorable effect from an undifferentiated histology, the absence of neck metastases, a younger patient age at diagnosis, and more intensive RT regimens for disease control and survival.  相似文献   

11.
BackgroundPractice of Unflattened or Flattening filter free (FFF) beam has become the high dose standard in radiotherapy (RT), such as stereotactic radio-surgery (SRS) and stereotactic radiotherapy (SRT). The removal of a flattening filter (FF) from the path of a photon beam alters the characteristics of FFF beam. Since the conventional route for dosimetric analysis of FF beam cannot be applied to FFF beam, the procedure of analyzing beam characteristics for FFF beam based on inflection points (IPs) is used. IP is a point where the concavity change observed corresponds to its change in sign (±) of the second derivative.AimThe objective of the study is to determine IPs for dosimetric analysis of the FFF beam profile.Methods and materialsIn this study, IPs are determined through the python code programming based on the mathematical first principle of the derivative. They are compared with IPs estimated by the conventional graphical manual method using Microsoft Excel (MS). IPs and their dependent dosimetric parameters determined by both mathematical and graphical manual methods are compared.ResultPercentage differences between the IPs determined by both methods, for 6MVFFF inline and crossline beam profile are found to be 2.7% and 0.8% respectively. Similarly, the average penumbra differences for 6MVFFF inline and crossline beam profile are found to be 0.15 mm and 0.9 mm, respectively. However, differences in the field width between both methods are found insignificant.ConclusionGraphical manual method is very time-consuming, tedious and user dependent. However, the mathematical method through python code programming is more precise, faster and independent of individual users.  相似文献   

12.
Background/AimTo analyse clinical response, overall (OS) and disease free survival (DFS) and toxicity in patients with unresectable oesophageal cancer treated by concomitant chemo-radiotherapy (CRT).Materials and methodsForty patients with stage IIa–IVa biopsy proven oesophageal carcinoma were treated with CRT. All patients were studied with endoscopy and CT and judged unresectable after multidisciplinary discussion. CRT consisted of 3 cycles of cisplatin 100 mg/m2 or carboplatin 300 mg/m2 on day 1 and 5-fluorouracil 1000 mg/m2 as a continuous infusion of 96 h associated with concurrent 3D-conformal RT. By using 15 MeV X-rays, a total dose of 60–66 Gy was delivered with daily fractions of 1.8–2.0 Gy.ResultsComplete response (CR), partial response (PR) and no response (NR) were observed in 50%, 20% and 20% of cases, respectively. Of the 20 patients with CR, 15 developed loco-regional recurrent disease. OS and DFS rates at 3 and 5 years were 38%, 8%, 49% and 10%, respectively. Total radiation dose ≥60 Gy improved loco-regional control and complete response (CR vs. PR + NR; p = 0.004) influenced both DFS and loco-regional control. Grade 3 gastrointestinal and haematological acute toxicity occurred in 3/40 patients (7.5%). One patient developed grade 4 renal failure. Late toxicity was reported in 2/40 patients (5.0%), consisting of grade 3 radiation pneumonitis.ConclusionsConcomitant CRT for unresectable oesophageal cancer can result in an acceptable loco-regional control with limited toxicity. Response after treatment and total radiation dose influenced the outcome.  相似文献   

13.
AimThe aim of the study was to evaluate computed tomography (CT) artifacts and image recognition of the CyberKnife system. Regarding fiducial markers, VISICOIL of 0.5 mm × 5.0 mm and 0.75 mm × 5.0 mm, ball-shaped Gold Anchor (GA) of 0.28 mm × 10 mm and 0.28 mm × 20 mm, were compared with the standard cylinder marker of 0.9 mm × 3.0 mm (ACCULOC).BackgroundRecently, various kinds of commercial fiducial markers have been available in CyberKnife treatment.Materials and methodsThe CT images of a water equivalent gel with each fiducial marker were acquired for the evaluation of CT artifacts. The evaluation was performed using the standard deviation of Hounsfield Unit (HU) value for a rectangle region near the fiducial marker. Then, to evaluate the image recognition, each fiducial marker was located to overlap in the target locating system (TLS) for the two sites; the vertebral bone and the pubic bone.ResultsFor CT artifacts, the standard deviations of the VISICOIL of 0.5 mm × 5.0 mm was the smallest. The image recognition of four fiducial markers had a value close to the standard cylinder marker and was feasible for common use, but was slightly poorer when using GA of 0.28 mm × 10 mm in the dynamic conditions.ConclusionOur results indicated that VISICOIL 0.5 × 5.0 mm and the GAs can be used nearly always for CyberKnife treatment in spite of their much thinner needles than those of cylinder types.  相似文献   

14.
15.
PurposeProton therapy with Pencil Beam Scanning (PBS) has the potential to improve radiotherapy treatments. Unfortunately, its promises are jeopardized by the sensitivity of the dose distributions to uncertainties, including dose calculation accuracy in inhomogeneous media. Monte Carlo dose engines (MC) are expected to handle heterogeneities better than analytical algorithms like the pencil-beam convolution algorithm (PBA). In this study, an experimental phantom has been devised to maximize the effect of heterogeneities and to quantify the capability of several dose engines (MC and PBA) to handle these.MethodsAn inhomogeneous phantom made of water surrounding a long insert of bone tissue substitute (1 × 10 × 10 cm3) was irradiated with a mono-energetic PBS field (10 × 10 cm2). A 2D ion chamber array (MatriXX, IBA Dosimetry GmbH) lied right behind the bone. The beam energy was such that the expected range of the protons exceeded the detector position in water and did not attain it in bone. The measurement was compared to the following engines: Geant4.9.5, PENH, MCsquare, as well as the MC and PBA algorithms of RayStation (RaySearch Laboratories AB).ResultsFor a γ-index criteria of 2%/2 mm, the passing rates are 93.8% for Geant4.9.5, 97.4% for PENH, 93.4% for MCsquare, 95.9% for RayStation MC, and 44.7% for PBA. The differences in γ-index passing rates between MC and RayStation PBA calculations can exceed 50%.ConclusionThe performance of dose calculation algorithms in highly inhomogeneous media was evaluated in a dedicated experiment. MC dose engines performed overall satisfactorily while large deviations were observed with PBA as expected.  相似文献   

16.
AimThe aim of this study was to compare the outcomes, patterns of failure and laryngeal preservation rates in patients with T1N0 glottic cancer treated with surgery or radiotherapy.Materials/methodsRetrospective study of T1N0 glottic cancer patients treated in our institution between January 2007 and December 2017. Histologically proven squamous cell carcinoma patients, treated with upfront cordectomy/partial laryngectomy (S group) or radiotherapy (RT group) were included. Elective treatment of the neck was not permitted. Local failure (LF), disease-free survival (DFS), ultimate disease-free survival (UDFS), laryngectomy-free survival (LFS), disease-specific mortality (DSM) and overall survival (OS) were evaluated.ResultsTwo hundred and one patients were eligible (172 S group, 29 RT group), with a median follow-up of 38.8 months. Overall, 33 (16%) patients had a recurrence, 30 (17%) in the S group and 3 (10%) in the RT group. Local failure was the predominant site of failure (28 S, 2 RT). Overall, of all those that were salvaged, 17 (8%) underwent total laryngectomy (15 S, 2 RT). There was no significant difference in the 5-year cumulative incidence of LF (20.8% S, 8.1% RT, p = 0.138), 5-y LFS (85.0% vs. 91.7%, p = 0.809), 5-y DFS (67.5% vs. 82.1%, p = 0.343), 5-y UDFS (82.5% vs. 90.3%, p = 0.647) and 5-y OS (84.5% vs. 90.3%, p = 0.892). Multivariate analysis showed no correlation between initial treatment and the analyzed outcomes.ConclusionPrimary surgery or radiotherapy were similar first line options, since they do not differ in all outcomes. Patients’ and physician's preferences must be considered when choosing first treatment.  相似文献   

17.
《Cancer epidemiology》2014,38(1):73-78
Purpose: Preoperative chemoradiation has been established as standard of care for T3/T4 node-positive rectal cancer. Recent work, however, has called into question the overall benefit of radiation for tumors with lower risk characteristics, particularly T3N0 rectal cancers. We retrospectively analyzed T3N0 rectal cancer patients and examined how outcomes differed according to the sequence of treatment received. Methods: The Surveillance, Epidemiology, and End Results (SEER) database was used to analyze T3N0 rectal cancer cases diagnosed between 1998 and 2008. Treatment consisted of surgery alone (No RT), preoperative radiation followed by surgery (Neo-Adjuvant RT), or surgery followed by postoperative radiation (Adjuvant RT). Demographic and tumor characteristics of the three groups were compared using t-tests for the comparison of means. Survival information from the SEER database was utilized to estimate cause-specific survival (CSS) and to generate Kaplan–Meier survival curves. Multivariate analysis (MVA) of features associated with outcomes was conducted using Cox proportional hazards regression models with Adjuvant RT, Neo-Adjuvant RT, No RT, histological grade, tumor size, year of diagnosis, and demographic characteristics as covariates. Results: 10-Year CSS estimates were 66.1% (95% CI 62.3–69.6%; P = 0.02), 73.5% (95% CI 68.9–77.5%; P = 0.02), and 76.1% (95% CI 72.4–79.4%; P = 0.02), for No RT, Neo-Adjuvant RT, and Adjuvant RT, respectively. On MVA, Adjuvant RT (HR = 0.688; 95% CI, 0.578–0.819; P < 0.001) was associated with significantly decreased risk for cancer death. By contrast, Neo-Adjuvant RT was not significantly associated with improved cancer survival (HR = 0.863; 95% CI, 0.715–1.043; P = 0.127). Conclusion: Adjuvant RT was associated with significantly higher CSS when compared with surgery alone, while the benefit of Neo-Adjuvant RT was not significant. This indicates that surgery followed by Adjuvant RT may still be an important treatment plan for T3N0 rectal cancer with potentially significant survival advantages over other treatment sequences.  相似文献   

18.
PurposeHigh precision radiosurgery demands comprehensive delivery-quality-assurance techniques. The use of a liquid-filled ion-chamber-array for robotic-radiosurgery delivery-quality-assurance was investigated and validated using several test scenarios and routine patient plans.Methods and materialPreliminary evaluation consisted of beam profile validation and analysis of source–detector-distance and beam-incidence-angle response dependence. The delivery-quality-assurance analysis is performed in four steps: (1) Array-to-plan registration, (2) Evaluation with standard Gamma-Index criteria (local-dose-difference  2%, distance-to-agreement  2 mm, pass-rate  90%), (3) Dose profile alignment and dose distribution shift until maximum pass-rate is found, and (4) Final evaluation with 1 mm distance-to-agreement criterion. Test scenarios consisted of intended phantom misalignments, dose miscalibrations, and undelivered Monitor Units. Preliminary method validation was performed on 55 clinical plans in five institutions.ResultsThe 1000SRS profile measurements showed sufficient agreement compared with a microDiamond detector for all collimator sizes. The relative response changes can be up to 2.2% per 10 cm source–detector-distance change, but remains within 1% for the clinically relevant source–detector-distance range. Planned and measured dose under different beam-incidence-angles showed deviations below 1% for angles between 0° and 80°. Small-intended errors were detected by 1 mm distance-to-agreement criterion while 2 mm criteria failed to reveal some of these deviations. All analyzed delivery-quality-assurance clinical patient plans were within our tight tolerance criteria.ConclusionWe demonstrated that a high-resolution liquid-filled ion-chamber-array can be suitable for robotic radiosurgery delivery-quality-assurance and that small errors can be detected with tight distance-to-agreement criterion. Further improvement may come from beam specific correction for incidence angle and source–detector-distance response.  相似文献   

19.
AimThe aim was to find an optimal setup image matching position and minimal setup margins to maximally spare the organs at risk in breast radiotherapy.BackgroundRadiotherapy of breast cancer is a routine task but has many challenges. We investigated residual position errors in whole breast radiotherapy when orthogonal setup images were matched to different bony landmarks.Materials and methodsA total of 1111 orthogonal setup image pairs and tangential field images were analyzed retrospectively for 50 consecutive patients. Residual errors in the treatment field images were determined by matching the orthogonal setup images to the vertebrae, sternum, ribs and their compromises. The most important region was the chest wall as it is crucial for the dose delivered to the heart and the ipsilateral lung. Inter-observer variation in online image matching was investigated.ResultsThe best general image matching position was the compromise of the vertebrae, ribs and sternum, while the worst position was the vertebrae alone (p  0.03). The setup margins required for the chest wall varied from 4.3 mm to 5.5 mm in the lung direction while in the superior–inferior (SI) direction the margins varied from 5.1 mm to 7.6 mm. The inter-observer variation increased the minimal margins by approximately 1 mm. The margin of the lymph node areas should be at least 4.8 mm.ConclusionsSetup margins can be reduced by proper selection of a matching position for the orthogonal setup images. To retain the minimal margins sufficient, systematic error of the chest wall should not exceed 4 mm in the tangential field image.  相似文献   

20.
PurposeDynamic treatment planning algorithms use a dosimetric leaf separation (DLS) parameter to model the multi-leaf collimator (MLC) characteristics. Here, we quantify the dosimetric impact of an incorrect DLS parameter and investigate whether common pretreatment quality assurance (QA) methods can detect this effect.Methods16 treatment plans with intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT) technique for multiple treatment sites were calculated with a correct and incorrect setting of the DLS, corresponding to a MLC gap difference of 0.5 mm. Pretreatment verification QA was performed with a bi-planar diode array phantom and the electronic portal imaging device (EPID). Measurements were compared to the correct and incorrect planned doses using gamma evaluation with both global (G) and local (L) normalization. Correlation, specificity and sensitivity between the dose volume histogram (DVH) points for the planning target volume (PTV) and the gamma passing rates were calculated.ResultsThe change in PTV and organs at risk DVH parameters were 0.4–4.1%. Good correlation (>0.83) between the PTVmean dose deviation and measured gamma passing rates was observed. Optimal gamma settings with 3%L/3 mm (per beam and composite plan) and 3%G/2 mm (composite plan) for the diode array phantom and 2%G/2 mm (composite plan) for the EPID system were found. Global normalization and per beam ROC analysis of the diode array phantom showed an area under the curve <0.6.ConclusionsA DLS error can worsen pretreatment QA using gamma analysis with reasonable credibility for the composite plan. A low detectability was demonstrated for a 3%G/3 mm per beam gamma setting.  相似文献   